Text

I'.

ATTACHMENT Consumers Power Company Palisades Plant Docket 50-255 NOTIFICATION OF SUBMITTAL OF REQUEST FOR RENEWAL OF THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT April 13, 1994

consumers Power March 25, 1994 Mr William Shaw , 21E01M90518.6 Surface Water Quality Division DAO 94-025 Permits Section Michigan Department of Natural Resources PO Box 30273 Lansing, MI 48909-7258 NPOES PERMIT RENEWAL APPLICATION - MI0049131 Dear Mr Shaw Attached for your review is a standard NPDES Permit Application Form for the discharge of treat~d groundwater to Lake Michigar resulting from remediation of a chlorinated sp1vent release at the Palisades Nuclear Plant. The existing NPDES Permit No MIP049131 for this discharge is set to expire on October l, 1994.

A note written under Item 5 of Section II of the Permit Application Form requires explanatibn. None of the waste water characteristics listed in Part A of Item 5 wi11 be increased above background levels during the treatment and discharge of groundwater to Lake Michigan. Therefore, we request a waiver from sampling and reporting these discharge characteristics.

lf you need any further information regarding the permit request, please contact me at (517) 788-2980.

Sincerely David A Olsen, PE Environmental and Technical Services A CiffS' ENCRGiY' COMPANY

- -------- ---* ------*-----*--*~-;**=--.------

EPA 1.D. NUMB '1M'1r1D10 19 ~ ~ j4-*{t 16 1s- i2 I.

, *1 -SECTION I' '.,2:g*l.

t . PERMIT NUMBER' ... ,1M1T1D io lJ. fr.'.' ~9 .i l!l' ..

SEE INSTRUCTIONS APPLICATION FOR DISCHARGE PERMIT IS:* ..

ON REVERSE.SIDE EXISTit<<;

o* [j-l'l.>DIFIEJICN INCREASED USE REISSIWCE D I[)

ITEM A. PARENT CIM'ANY/!FT./CMNER

~ Q 1N e l! !I! j -~ 81 ~ I 01WjE 1R I ~ Q l! ~ ~ N Y1 I I I I I I* I I I B, DIV ./BUlEALI I N1A1 I. I 1* I 1 c. Pl.ANT OR FACILITY I I Ip I A 1L I I 18 I I I IA ill E ~ I I I I I I

I I

I I* I I I I E1 I I I I I I STANlARD INIXJSlRIAL CLASSIFICATION I I I I I I I I I I I *(REFER lO TABLE II)

PHYSICAL D, TYPE OF FACILllY 1N1U1C1L 1E 1A !!!: I P101W 1E  !!!: I E. ~  ! I 14 ~ ~ ~ I I I I I I I I I I I LOCATION F, SlREET NlMlER G, SlREET l'W£

~ ' .

ADDRESS 12 17 17 ~ e I I I I ~ :t* £ -~

18 1T -t:. ~ 1M1E IM I l! ~ t:* I I I I I I I H. CllY twE I, ZIP CODE AND INFORMATION IC 1Q l:ll E R I I I I I I I I. I I I I I I I I I Ml 14 19 10 4 j*31 J, ~IP K, COlJfTY (REFER lO TABLE I)

,c 10 1V ~ l! t I I I I I I I I I I I CO, .NAME VAN BUREN CO, Nt.ffiER ~

L, twE OF AUTlfJRI ZED CONTACT PERSON M, TITLE.

1A1N IT N, TElEPlllNE NlM!ER I! e~ I ICIAILIL lo ~ ~I o.

I I I I I ADJJlESS (IF DIFFERENT FRa1 ABOVE)

I I

~**~

~ f! IC IH ~ ~ I ~ J i I 1* I 16 11 16 I  ? ef I 1819 11 13 I IN IA I I I I I I I I I I I I 'I I I I I I I

' P,

  • CllY ffAloE Q, STATE R, ZIP cODE IC lo Iv ~ ~
s. 1YPE OF lREAlMENT FACILilY I I I I I I I I I I I T,

I I I I I. I l'ROGRAM FOR* EFFECTIVE RESilllW..S MAWIGEl-ENr

~ 1 1 4 9

'° f ~ I (REFER 10 TABLE II) . DATE Sll!MITIED. ..

lLK...J LL..J LL...J L1-J L.LJ o-.YES ON> liJN.A, mTE IMPL&ENTED

u. BACK-ti' Pal'ER SOUlCE v. POLLUTION INCIDENT PREVENTION PLAN .. w*. NJoEER OF
  • mTE
  • Sl.llfllTIED E11'LOYEES Dves [B NJ D N,A, DYES ONO [!)*N.A,* DATE. IMPIBENTED I I I I 6 5 I p I
x. 'TYPE OF DISOW<GE GROIHl'IATER D. Y, IXI YOU WIVE A ~IFiED OPERAl<f *mYEs. -*DNo Ot'e>.11rul s l'WE. thony Cal away s.s.#13.1614 1 ~ 1413 17 (!_ I I!OlH D SURFACE WATER Ii] 8 FACILllY # 1 IO 10 e ~ f I CERTIFICATION # I tl I 2 18 14 11 I I I ITEM A.

IT twE i!! e. !'.! ~ ~ I 1P1A1L ~ i!* ~  ! !!'. 9 I I I I I I I I I I I I I I I 2 B. l'W£ MAILING ADDRESS 1A 1N 1T I! Q }! I I 1C ~ i!:! I:! ~ NA Yj I I I I I I I I I *1 I' I I I I

  • OF c. SlREET P.DmESS OR POST OFFICE OOX APPLICANT 12 17 l ~ 2 1B1L 1U1E I ~ i!: ! !l 1M ~ I:! 2 ~ i ~  !:i l! }'.!. r** I I I r I I I

.D. CllY tw£ - .. E,. STATE. F*,

.. .* .o

- ZIP (:OD!; - .

,c e¥ ~ ~ I I I I I I l I I I I I I I I I I ~ 4

. I 9 I 9'4 I i I REQUIRED SIGNATURE I, the appl!cant, certify under penalty of law that I have personally examined and am*famillar with the Information submitted in this application and al I a-ttachments and that, based on my Inquiry of those Individuals lnrnedlately _responsible for obtaining the Information, I believe that the Information Is true, accura-te and canplete. I irn aware that there are significant penalties for submitting false Information, Including the*

possibi I !fy of fine and imprisonment.

. SIGNAX APPLICANT SIGNATUR.E OF LOCAL GOVERNMENTAL REPRESENTATIVE (SEE NOTE ON REVERSE SIDE)

!iI!ifllllllBE* ~ ~~ oBIE*J Ash.tL SI!.i~AI!!RE; NA l!.8IE*

NAM!;;: 'IHrnAS PAIMISOO TITLE: ~MANAGE& NAME: TITLE~

15

I PERMIT W r *..

SEE: INSTRUCTIONS

.NUMBER _. . ~-- MI0:049T31',

. ON* REVERSE SIDE.

ITEM A, r-u.ICIPAL

......,. 1N1A1 *I .,

i' 3 B, SlllFACE WATER INTAKE I . I I GAU.ONsfDAY

!WE OF WATERWAY ,N 1 A 1 I I SOURCE

\. OF QUANTITY (/w(,) I. I GAU..ONSfDAY ..

WATER SUPPLY c, PRIVA'TE WELL QUANTITY (MAX,) 1 N1A, ,. I GALi.oNslDAY D, OTHER

- *~ SPEl".Tl=Y

'i QUANTITY (MAX,) I ., I GAU.ONsfDAY A, PROCESS WATER (INCLUDING CONTACT *

  • ITEM <IXlLING WATER)

B, l'llNCONTACT COOLING WATER

  • QUANTITY (MAX, ) 1N- rA I GALLJ:iNS!DAY 4 c. SANITARY WATER QUANTITY (MAX;) 1N rA r
  • 1* I GALLONS/DAY FACILITY QUANTITY (MAX;) 1N rA WATER D*. OTIER

. soi=rtcv N A I I I 1.

USAGE Q!Wl!TTY (MAX,)

NAME OF SUBSTANCE. .- -.:. .,*__ :~ r- : - .:.:

ITEM .....

a:

w .. PNWETER NlM3ER NA

. ;.y*

5 - .

a . QUANTITY

!" I I UNITS I I LJ/YEAR CRITICAL

.i MATERIALS ...... NAME OF SUBSTANCE

=

WN PNWETER MM!ER I I I I I

.J". ;

PRIORITY  !;;:

POLLUTANTS' :a-QUANTITY UNITS  :.:>

I* I I L.Jlv-fAA USED -.

'NAME {)F SUBSTANCE:._'. -* *"" *~:<'-:~:'  :':_ i*-+-.; "-

  • STO~Etr~-

" ~,

~ :~

a: PARAl-ETER tu1!ER

-- Ill&") " I I I I I *,~:.

PRODUCED l:c 2* QUANTITY.. : LtllTS

!' "I L.J/YEAR _,.

REFER tw-E OF Sl.BSTANCE

. TO  :$

TABLES w.,

a:

PARN£TER MM!ER I I -7 ~ ~

IV&V

,,_ le UNITS 2 QUANTITY ,. LJ/YEAR

  • UNITS CODE .*. .._..:*- ... ...

..... NAl-E OF SUBSTANCE -., ..;:'

I POUNDS <-

2 GALLONS 3 CUBIC

=

WU) le PAIWETER MMlER I I UNITS, YARDS-2 QUANTITY- -~**(:i,_: : __ ~' *r . - '*- -- -.-

  • ~* .. ..

I I L.J /YEAR'.'*-*,,,,.., .:, ;*~'"':_.:<

i TONS

...... NAME OF SUBSTANCE '" *'

ffico Ii-PNWETER N!MlER I I I- I ,. I' ....... .,. ..:*~;'~*2*

2 QUANTITY

\J'llTS L.J/YEAR NAME OF

  • SUBSTANCE
  • i.

ffi,... PAIWETER M.MBER l:c

. ,,:~.-,--'"'."'"----.L.:-...J----------~--------------------------.J.--------..:_--...!~b::::!::::::b~~--b::::!:::d_...b~~~l~T~~YEAR~~-===~~l 2 QUANTITY 17

SEE lfrJSTRUCTIONS e: SECTION* T -**

. ~DR:i . ........

1 .* MI004913L.

. .-"'"---------._~*.:.-':*

- r-

  • ON REVER~: SIDE. *.:**:.:- :.:*** *\* .. , :.,* ~- ,.:;.:*.*~;-~~**.:** ...: .. _. :- .. .. ., *: *.c***

A*. PROVIDE A BRIEF DESCRIPTIOO AND LINE DIPGRA'i SIQlltG THE WAlER FLCM 'llRlU3H YOUR FACILITY fila.t."lrrr.\ia; 10 DISOMiE.. 'stO. Alf:~;.;~.

<lllflRIBUfltG WASTEWA1ER1 INCUJDltG PROCESS NlJ PROI:u:TION AP.EIS, SANITARY FLOWS-, (X)()LJNi WATER, AND STOlffolATER RlHlFf, YOU MAY GJiClll>*

SIMILAR OPERATIONS INTO A Sll'<<3LE ~IT, ll£ WATER l!Al.At<<:E SIOJLD.stOl*AVERAGE:fl.DojSi. SIPI ALL SIGNIFICANT LOSSES OF WATER TO PROI:u:TS1 AlMlSPHERE1 AND DISCfWlGE, YOU Slllll.D USE ACru\L MEASLREMENTS h'IENEVER AVAJl.ABl...EJ .OTHERWISE USE YOUR BEST ESTIMATE; .

A .groundwater treatment system was installed at the Palisad.es Plant in conjunction with a soil vapor extraction ~ystem to remedlaie groundwater .and soil DESCRIPTION contaminated by Tetrachloroethylene (PCE) and Trichloroethylene (TCE). Ground-:

water is pumped from .two extraction wetls,. as well as from the "soil. vapor.

AND extraction system knockout tank, to an air-stripping tower.* Air is forced into. the tower bottom by a blower to remove voiatile organic~ com.pounds (TCE *& PCE) from the DIAGRAM groundwater. The treated water collects in the air-stripper sump, from which point the water is gravity fed to a &torm sewer drain* that discharges to Lake Michigan via NPDES Outfall 004. The air is directed through twovapor phase granular-activated car.hon filters to remove the remaining volatile organic compounds to below specified limits. This treatment process is schematically shown below: *

\.

KNOCKOUT TANK "&:.Nr ro

.ATMDSPK-ER.E A\" 100SCFM i.oo SOIL VAPOR E. XT' R.j.C"1" ION LA. T' E. ~A. LS C:,CFM l

u.

u II')

0

,. 0

' ..( \ti

' *~ '

.*F\ LT E.R S '.: . : ....

  • 814.&

FlLTE.R WATE.R

.. * \S C:::rPM -Fl.us-\-\*

~o &PM ...-..a..-*....,T AN ~

,
AU~ . ,:*.

- -- - _.-t STR \ PPE.R..

50 0

~c-F M . .___ _,__ __.

A\R_

r R~c. \~C. *-,_; ..._,-_ *'*- .. . *._:_**.*:

EXTR~CTlON IRE.A.TE.b '\rl"-TER *-: ,*** *.: ..... *:*-

\Al E.LLS. qo. ~ Pl"'l t-JPDE.S L"'K E.

1-----~ 0 U"t' FA. LL J----1~ HICi-\lG.AN OOL\

19

5n -

~

az LAKE MICHIGAN Fuel Depot Site Groundwater Treatment System en m

(')

-0z

-i

'3 .

  • '~
  • l*Pl'l&IUl...-. .-*-.r .. ~~11-11,~ * :~~~~~J::wt'IUlllll.l;l,.*11~,

_[]_ ~~~~ ... __.,_.,_,.._.........._ .... _,,,-411._..... _

$tJJ'l>O!IT BIJl!Dlt/C -

Rl!lllL'IWG a 111'.U.--

PALISADES NUCLEAR PLANT - SITE PLAN I

e

.ECTION I ~t'l,'1/lR ~* 1. MI0049131 I ~ .

SEE INSTRUCTIONS r ON REVERSE SIDE A, 00 YOU OP~TE A COrcENTRATED ANl~)EEDIMi FACILHY? IF 00 cor-m.r<<.e 10 IT&!

ITEM 0 YES ~ 00 8 a. Nl1'1BER OF AOlES USBJ FOO CONFINB-ENT FEED!Mi?

I I I I '.LJ.._J AO<E5

c. IF TI£RE IS OPEN CONFINEf'ENT, ~ ?IFRLHJFF CONCEN- CONTROL SYSTEM BEEN CONSlROCTED.

DIVERSION Af.ll foD, CONTIMJE 10 ITEM 9) D YES D 00 TRATED ANIMAL

o. l+i.4T IS lHE DESIGN BASIS FOR n£ CONlROL SYSTEM? 0£CK ONE OF TIE FOLl..C1r'l!Mi AND ENTER NlM!ER OF 11'0£5 OF. RAIN? D 10 YEAR, 24 HOl.R STORM . Ll.........J **LI IOCHES FEEDING OPERATION D 25 YEAR.. 24 ~ snm L.J.._J' LI INCHES TYPE I I I I I I I I I I I I I I I I D OTH:R (SPECIFY) L.J.._J' LI INCHES E, MiAT IS M MM!ER OF ACRES OF CONlRIBUTIMi DRAINAGE?

I I I I

  • LJ.._J ACRES F, l+i.4T IS lHE DESIGN SAFETY FACTOR FOR lHIS t:0NTR0L SYSTEM?

LJ 'L...J

. A, LIST TYPE OF. ANIW\L, I I I I I I I I I I I I I I I I I I I I 1.

w a.

ITEM Q.

I-GIVE lHE MMlER OF lHIS TYPE OF ANIW\L IN OPEN COtl'INe£Nr, I I I I I I I I I I 9 c. GIVE lHE NlJBER OF lHIS TYPE OF ANIW\L IN 1-0USBJ CONF!reENT, I I I I I I I I I I A, LIST TYPE OF ANIW\L, TYPE I I I I I I I I I I I I I I I I I I I I I w

& ~C\I a. GIVE lHE MMlER OF lHIS TYPE OF ANl1'W... IN OPEN NUMBER I-CONF I Ne£NT, I I I I I I I I I I OF c. GIVE lHE MMlER OF lHIS TYPE OF ANIW\L IN t<<JUSBJ CONFI PJCMC>n", I I I I I I I I I I ANIMALS A, LIST TYPE OF ANIW\L, IN I I I I I I I I I I I I I I I I I* I I I I w a. GIVE lHE NIMlER OF lHIS TYPE OF ANIW\L IN OPEN OPEN ~C') CONFINe£NT, I I I I I I I I I I AND I-

c. GIVE TIE MM!ER OF lHIS lYPE OF ANllW.° IN 1-0USED .,

HOUSED CONFINB'ENT, I I I I I I I I I .~ ..

CONFINEMENT A. LIST TYPE OF ANIW\L, I I I I I I I I I I I I I I I I I I I I I w a. GIVE lHE MM!ER OF lHIS TYPE OF ANIW\L IN OPEN

~..,. CONFil'e£NI",

I-

' I' I I I I I I I I I

c. GIVE lHE MM!ER OF lHIS TYPE OF ANIMl\L IN l()(JSBJ CONFTM=MENT I I I I I I I I I I A, LIST lYPE OF ANIW\L, I I I I I I I I I I I I I I I I I I I I I w

g,:11) a. GIVE lHE MM!ER OF lHIS lYPE OF ANIMl\L IN OPEN I- COM=! l'e£NI"' I I 1* I I I I I I I

c. GIVE lHE MM!ER OF lHIS TYPE OF ANUW. IN 1-0USBJ I I I I I I I I I I CONF!Ne£NT, A, LIST lYPE OF ANIMAL, I I I I I I I I I I I I I I I I  ! I I I I w.

~co B, GIVE TIE MM!ER OF lHIS TYPE OF ANIIW.. IN OPEN I- CONFil'BENT, I I I I I I I I I I

c. GIVE lHE MM!ER OF lHIS TYPE OF ANIIW.. IN H'.lU5ED CONFiret:NT, I I I I I I I I I I A, LIST lYPE OF ANIW\L, I I I I I I I I I I I I I I I I I I I I I w .,

~,... a. GIVE T1£ MM!ER OF lHIS lYPE OF ANIIW.. IN OPEN I I *'I I I I I I-I I I

c. GIVE lHE MM!ER OF lHIS TYPE OF .An11'W... IN lill.ISED CONFil'EMENT, I I I I I I I I I I A. LIST lYPE OF ANIMl\L, I I I I I I I I I I I I I I I I I I I I I LU. a. GIVE lHE NlMIER OF* lHIS lYPE OF ANIMl\L IN OPEN I

~co COtl'I NEMENT, I I I I I I I I I I I-

c. GIVE lHE MMlER OF lHIS TYPE OF ANIMl\L IN 1-0USED CONFI re-ENT, I I I I I I I I I I 23

.~*

SEE INSTRUCTiONS SECTION I PERM.

NUMB * ... L..l_M_r_o_o_49_1_3_1_._ __,[

ON REVERSE SIDE  : *~.

A. llO YOU OPERATE AN AGUCITIC &-iIMAL PRO!lX:TION FACILIIY'?

ITEl'I 12ZJ ITEM (IF r<<J, CONrIM.E TO D YES 10 B, INDICATE THE TOTAL IUBER OF SlRLCTtRES AT YOLR FACILilY, POl{)S, RACEWAYS iWD SIMILAR ._I__.1_._1___.! , POM)S I I I I

  • RACEWAYS AQUATIC ANIMAL SPECIFY I I I I I 1* I I I I I I I I I I I l,Oll£R PRODUTION c, INDICATE IN l'HICH CALENDAR MJNTH MAXI1111 FEEDING OCCLRS, FACILITY I I I I I I I I I

,,., D, ENTER THE TOTAL NlMBER OF POlNlS OF FOOD FED Mil'li 1HIS r1'.JNTH? I I I I I I I I I I POIN'4':

A. IS "THIS SPECIE A WARM OR COLD WATER SPECIE?.

D WARM D COLD ffi ITEM B, GIVE "THE NA'E OF "THIS SPECIE, e~i----------------------------------------~-------=l=='===l=='==='=='==='::::::.'==='::::::.'===I::::::.'==='::::::.'==='=='==~'----~

c. ENTER TI£ TOTAL HARVESTABLE WEIGIT OF nus SPECIE 11 11.

en D,

PROWCED BY "THIS FACILilY PER YEAR IN POLMJS, ENTER TIE MAXI!'DI WEIGHT PRESENT FOR THIS SPECIE ltiICH I I I I I I I I POtNlS l'IOl.lD REPRESENT YOLR IO<M>\L OPERATION. I I I I I* I *POlNlS SPECIES A. IS "THIS SPECIE A WARM OR COLD WATER SPECIE!

OF I I I I ax.n AQUATIC en w B, GIVE THE NA/ OF THIS SPECIE, ANIMALS

=========='==============='============::::::----~

1 1 1 1 1 1 1 1 1 1 1 1 1 1 PRODUCED UNI----------------------------------------""""-------='

w

11. C, ENTER THE'TOTAL HARVESTABLE WEIGHT OF "THIS SPECIE AT THIS en PROIJOCED BY "THIS FACIUlY PER YEAR IN POINJS, I I I I I I POlWS FACILITY D. ENTER 1liE MAXl1111 WEIGIT PRESENT FOO "THIS SPECIE WHICH Wll!D REPRESENT YOLR l'llRW.. OPERATION, I I I I I I I I I !POt.tIDS en A, IS "THIS SPECIE A KllRf1 OR COLD WATER SPECIE?

D *KllRM LJ COlD B. GIVE "THE NA'E OF THIS SPECIE, 5Ml-----------------------_;.--------------'"""'-------=1::::1==:':::'==:'::::::'==:'::::::':::::':::':::::'::::::':=:':::':::::'==':::::'----~I w

11. c, ENTER THE TOTAL HARVESTABLE WEIGHr OF "THIS SPECIE en corwr-Rl BY "THIS FACIUlY PER Yl=AI> TN f'OlMlS, r I D, ENTER THE MAXl/111 WEIGIT PRESENT FOR "THIS SPECIE \ofiICH l'IOl.lD REPRESENr YOLR ~OPERATION, . I I I POt.tIDS en A. IS "THIS SPECIE A WARM OR COLD WATER SPECIE?

D D COLD

!!:! B. GIVE THE NAl'E OF THIS SPECIE,

  • _______________________....;,.______________""""______....:::*::::'==='=='==='=='==='==l===l==l==='==l===*=='===I=='==:'----~

irl""r-

11. C, ENTER TIE TOTAL HARVESTABLE WEIGHT OF THIS SPECIE en PROIJOCEll BY THIS FACILITY PER YEAR IN POIH)S, I I I I I I I I I I POtNlS D. ENTER THE MAXl1111 WEIGHT PRESENT FOR THIS SPECIE ltllCH l'IOl.lD REPRESENT YOLR taM!IL OPERATION, I I 1* I I I I I I I POlHlS en A, IS "THIS SPECIE A WARM 'OR COLD WATER SPECIE?

D WARM D COLD B. GIVE TIE 1-wE OF THIS SPECIE, 5~1------------------~------_;,,-------------1.------....:::L::=f==='=='==='==l==:l::::l==='*==l==:l:::::!:l==='=='==='=::'::::::~I----~

w

11. C, ENTER THE TOTAL HARVESTABLE WEIGIT OF THIS SPECIE en PROIJOCED BY THIS FACILITY PER YEAR IN POlHJS, I I I POllllS D. ENTER TIE MAXI/111 WEIGHT PRESENT FOR THIS SPECIE ltllCH llOUl.D REPRESENT YOU? rDlfW.. OPERATION. I I I I I I I I I I POlHlS en A, IS THIS SPECIE A WARM OR Cot.n. WATER SPECIE?

l J WARM LJ w B. GIVE TIE tWE OF THIS SPECIE. I I 1 I I I *I u~1-----------------~~--------~--------'"""'-------='=='==='==*==='==='==='===*

w =='==='=='==*===*===*==*===*====-'------

11. C, ENTER TIE TOTAL HARVESTABLE WEIGHr OF THIS SPS:IE. * :** *.i en PROCU:ED BY THIS FACIUlY PER YEAR IN POLfIDS, I I  !* POltllS  : .,

D, ENTER TIE MAXl/111 WEIGIT PRESENT FOR THIS SPECIE ltlICH l'IOl.lD REPRESENT YOLR tmolAI.. OPERATION, I I I I I I I I I I POlNlS 27

  • l e SECTION I l

~'O':v,~'i-~ . . _M_I_oo_4_9_1_31_*____j LIST NllME AND l'AILING ADDRESS OF ALL PROPERTY o.-.NERS ADJACENr TO TIE TREAlMENT FACILITV'AND OR 01scW<RGE/01sPOSAL .AREA.

ITEM 1. Van Buren *state Park 12 Department of Natural Resources

-Real Estate .Division

  • . PO Box; 30028 MAILING

.. Lansing, iMI 48909 LIST OF 2. Harold Vandersalm II 1324 Meadowbrook Lane ADJACENT Kalamazoo, MI 49001 PROPERTY OWNERS 3. Palisades Park County Club Route 2~ Box 161 Covert, MI 49043 29

PERMIT NO. MI0049131 Section II - Item 2 Outfall.004 Text for Parts D, E, F and G of Item 2, Page.31:

Due to the presence of mine~als in the groundwater, the packing material in the air-stripping tower is expected

- to accumulate scale during continuous operati*on. The scale, in turn, causes the tower pressure drop to exceed design limits. To remove the scale, the groundwater treatment system operation will be temporarily interrupted and a 5% sulfuric acid solution will pe recirculated through the the tower at a rate of 12 to 15 GPM for approximately 20 minutes. The acid solution is prepared in a chemical flush tank (X-102 GW) by mixing 6 gallons of 94% H so~ .

2 in 120 gallons of water. Upon completion of the acid cleaning, the waste water is collected in Tank X-102 GW to allow for sampling and 'neutralization with a 50% NaOH solution prior to discharge into the storm sewer line servicing this treatment system. Although there has not been a need to perform this cleaning operation as of the date of this permit renewal, it is anticipated that the cleaning may be required once or twice per calendar quarter.

  • I 9 SECTION 11 .

SEE INSTRUCTIONS ON REVERSE SIDE '*"*

pQ 141 ITEM A, LOCATION OF DISOW<GE ~ \;, t1!.J!LJ \;, .SECTIOO 1 *JL..2..J,. TMj 1 0 1 2 1 S r, RJWjE 11 j7 'tt1 1 B. :fu°i" RECEIVI~ WATER UE. GROLm!ATER OR NAME OF Sl.RFACE . ,L ,A 1K iE iM iI c ll ! G A N1 DISCHARGE

c. I,ll YOU DISCHARGE SEASONAL.LY [

. (IF Ml1 CONTIMJE TO E)

D' YES Ii] NO LOCATION D, IF YES, 1.IST DISCHARGE PERIODS 1'1), I DAY . 1'1), I DAY SCHEDULE

. L...L.J ' LJ.........J FLOW ~ ~

  • llRll.GH * **' ~ LJ.........J RATE WASTEWATERl-----------~~~-~~~--~-

, I .'i"

.......--.-.---i,.-,_.......,...___

r * .*,* * "\ I c>" .. "llflOll;H

~~/~.1.----======;-:---=====----

.. l__j__J L....J..._j IN,,tfl, . HR, DAY *' ** IN. WK, r;;i .,,

TYPE CODE E. LAND APPLICATION RATE LL..J

  • L.J L...l_j
  • L..J uu '""

CONTACT F, lYPE OF WASTEWATER DISOlARGE L.3..J WASTEWATER TYPE COI:E COOLING L.J. L-.J L..J L.J L..J 2 NONCONTACT G. "DISOlARGE SOIEIXJl:E (YEARLY AVERAGE) fO.RSIDAY l2_j{j,_J rY>.Y/YFAR I 3; 6 ! 5* !

COOLING 1--_::_..:.....___:~_,..._,..._,..._,..._,...~..:..__,..._,..._,..._,..._,..._,..._,..._,...~~!!!!!..-.--.-...!:=!:!::::!.-.--.--.-~~~-.-..!::::::::::!:::::::::..-.--.--.----

3 PROCESS H. DISOWlGE Fl!M RATE ' ***. * ** * *.

  • 0*' l.tlL...JITCODE TOTAi. YEARl.Y 4 SANITARY '.'l 5 . STORMWATER DAll.Y MINl"111 . I L L...J UNIT CODE rY\11.Y MAXl"111 ...:)~- . I+* j3 f 9 Q q " I .*. t1.i 1 MGY I, THE MAXIMll1 DISOW!GE FLC7W RATE To BE. AllTHCRIZED IN PERMIT, UNIT.. CODE 2 MGD AUTHORIZED i46?0QQ I ,j I 3 GPO J,. MAXl"111 DESIGN DISCHARGE.Fl.GI RATE.

DESIGN ,_,

  • i4 a ? er aa tiff[. CODE
  • LJ_J A, lXl YOU USE WATER lRE"AlMENT ADDITIVES lO lRE"AT YOLR DISOiAAC'.1;? -~*[JYES.*s ...

(IF NO, CONTINUE TO ITEM 3)

  • ITEM B. ~-~LtlCTION, AND CHEMICAi. CD"IPOSITION OF 1111;:>E ADDITIVES,
  • ., li!!l!IE. '.

Sulfuri'c. Acid* .,, . ". ** * 'Remove*~rron Scale

. . ,..,.. ,,*_;* o.* BKilW.

2 --(~5~%~.~S~o~l~n__..)-----.--.-- From Air Stripper

~.Packing x WATER ""'s""o-d...i....u-m.._,,,H,...y-d..-r_o_x--=-i-::d-e--.,...__ ..:.. Neut r a 1 i:z a tfim

  • TREATMENT *: (50%. SOln)* ~' **:*~ . . *c*>>,-:. *"****"* ,,.,.,.,,,,.,.~, ~
  • ADDITIVES NA'1E AND AD!llESS OF !Wf.FACTUlERS . .

C, OF THESE ADDITIVES.

VWR Scientific T;""!*ci-'.*.:;;~Jl ~*".°"':V i0 1 B*~x: 66929 ** ""

UNITS CODE Chic~g6,~rriinois 1 Mg/I - ~.:. ... ,, - _....

2 Ug/I ..:* .- - **.

- -~ - .-,::.:;.;- ._:;;** . . ... - **-*

D, EXPECTED DISOiARGE COtCENTRATION OF AIDITIVES. MINlfU1* UNITS AVERAGE lfjlTS MAXll'Y'! l.tllTS i-~. *1----------------------~

. '.*: >*'"5 ~ CODE, ' :'.: . , .** .: *.--*:;, , ,, .CODE *' .'~*:*:r CODE

.~! "::.l;"'!B~* :f:1 ~-~-- -.;-..-:.:: *-:t! ~,. *.71r:'* ,-.:-.

AIDITIVE NA"'E L...J ; I L...J ; I

._!_ _ . _ _ _ . . _ _ _ . _ _ _ . L...J ADDITIVE NA"'E L...J. ; ._! _._1__..___.__. L...J ; 1...__.___..___.___. L...J ADDITIVE NA"'E L...J; I L_J; I r LJ E, 00 YW lREAT lHE DISOiARGE lO REKlVE ADDITIVES?

F, WHAT IS 'THE ROOVAL EFFICIENCY N4D DISCHARGE FREQJENCY? DI SCJW!GE fREallfNC:V .

%ROOVAL HRS ./DAY DAvs/wi.:

ADDITIVE NA"'E LJ..._J LL..l *LJ Allll IT! VE NA'1E LJ..._J L..LJ L.J ADDITIVE NAME LJ..._J L..LJ LJ G. AS AA ATTAOf-IENT ro nils APPLICATI0'-1 PROVIDE SPECIFIC MA"t1ALIAN ffi AQUA.TIC lOXICOLCXHCAI. DATA ffi REFERENCE WHICH ARE AVAILABLE AND INRR'IATI0'-1 CW "!HE RATE OF DEGRADATI0'-1 OF THE PROD.x:TS F~ EAOi AllllTIVE. .

For Items D, E, F and G, see attached sheet 31

4tSECTION II PER. * ..1*. MI004913i.

NurlB-.-.....,. _

SEE INSTRUCTIONS ON REV.ERSE SIDE .... ?,:

UJTFAU. IUl1lER ,o 10 14 I ITEM A, rw1E OF PROCESS CONTRIBUTING 10 THE DISOiARGE THROUGH THIS OlJTFAU. AND SIC CODE I N1A1 I I T I I I I I I I I I I I I I I*

3 I/)

a. PROCESS SOiEIJU.C: (YEARLY AVERAGE)

HJt-'ls/DAY L_L_J DAYS/Y""' 1- I I I'

c. l.tl!T~

I/) PROCESS WASTEWATER FlD'I RATE. -

I .I I I PROCESS w

(.).- '

lOTAL YEARLY I I I I I I L.J STREAMS 0 -----*-- - --*---* *- -~ . -* *- - **-** -*~ ***---*-***

a:

Q. DAILY MINIMll1 I I I I I I I I I I LJ CONTRIBUTING TO .. .. .I DAILY MAXllUI, F I I I I I I *1 I L..J OUTFALL i.rv~

D. PROCESS PROllUCTION RATE ., l -*.

DISCHARGE I I I 1* I I I I I A* fW1E OF PROCESS CONTRIBUTING 10 lHE DISOiARGE .. . ' .. ..

THROlai THIS OUTFALI. AND SIC CO!lE I I I I I I I I i I I I I I I I I I I I

a. PROCESS SO£IlUL.E (YEARLY AVERAGE) .. ' ';;; .. ...  ;.:..J .*

,,. -1 HJLRs/DAY LJ.:_J . DAYs/YEAA I I I I/) UNll UJUE I/) c. PROCESS WASTEWATER FLOW RATE

- i. I w

UN ..

TOTAL YEARLY I I *r I I I 1* I L.J

o. .- .. ' .- . -

a:

Q.

DAILY MINIMLl'I I I I I I I I I I I LJ UNITS CODE 1 POUNDS DAILY MAXllUI I I I I I I. I I I *1 LJ 2 GALLONS D. PROCESS PRODUCTION RATE .. . .. I I I I i:*-, I I r --

Ltl17YiTIME LJ LJ 3 CUBIC A, NAME OF PROCESS CONTRIBUTING TO lHE DISCHARGE YARDS 4 TONS llflOUGH THIS OUTFALI. AND SIC aJDE I I I I r I I I I I I I I I 1* I I I I I *'

a. PROCESS SCl£llUlE (YEARLY AYERAGE) '

5 MGY HJLRs/DAY LLJ DAYs/YEAR I I I I I/)

6 MGO I/) l.tl!T CODE w c. PROCESS WASTEWATER FLOW RATE 7 GPO lOTAL YEARLY I I I I I I I I I I LJ 8<'

a:

Q.

DAILY MINIMl.1-l I I I I I I I I I. I LJ DAILY MAXllUI I I I I I I I I I I LJ TIME D. PROCESS PRODLCTION RATE I I I I I I I I I ~~

1 HOUR A, NAME OF PROCESS <DNTRIBUTING 10 T1£ DISOWlGE THROUGH THIS OUTFAI I AND SIC COOE I I I I I I I I I I I I I I I I I I I I 2 DAY 3 WEEK

a. PROCESS S0£DU..E (YEARLY AVERAGE) fOJRSiDAY LL.J DAYSIYEAA I I I I 4 MONTH I/)

l.tl!T CODE I/)

w c. PROCESS WASTEWATER FLOW RATE 5 YEAR lOTAL YEARLY I I I I I I I I I I LJ 8"'

a:

Q. DAILY HINllUI I I I I I I I I I I LJ DAILY MAX!l't..M I I I I I I I I I I LJ

c. PROCESS PRODOCTION RATE I I I I I I I I I ~~

A. NAME OF PROCESS CONTRIBUTING 10 T1£ DISOiMG£ THlOl.Gi TH IS OUTFALI. AND SIC CODE I I I I I I I I I I I I I I I I I I I I

a. PROCESS SO!EDLl.E ( YEAALY AVERAGE)

HJLRSIDAY L_L_J DAYs/YEAR I I I I I/)

I/) c. PROCESS WASTEWATER FLCJol RATE ~IT CODE w lOTAL YEARLY I I I (. I I I I I I L.J

<.Jin 0

a: I, I Q. DAILY HINllUI I I I I I I I I LJ DAILY MAXllUI I I I I I I I I I J L.J D. PROCESS PRODLCTION RATE I I I I I I I I I u~~l'E 33

-SECTION II PERMIT.>

NUMBER".

. ~ l__M_ro_o_4_9_13_1

_ _ _...J,-_

SEE INSTRUCTIONS

  • . .QK*REVERSE SIDE.

aJTFAll rum Q 10 14 I ITEM A, IS THE DISC~t FRO'! THIS OUTFALL DIREc5yn TO 1HE GROUND OR GROllND'IATERS. IF 00, CONTINUE TO ITEM DYES . IKJ f'D 4 a. HAS A HYDROGEOLOGICAL STIJDY OR ITS EQUIVALENT BEEN PERFO~ OR IS 1HERE SUFFICIENT OJRRENT HYDROGEOLOGICAL INFOO'IATION AVAILABLE AS REQUIRED ~y TfE WATER RESOURCES DYE~ D oo C<M-!ISSION PART 'll. GROLMMATER RULE~ OF Al.GUST 14, l9aJ R, 23.220] (P.AGE !15.) FOR GROUNDWATER 1HIS EXIST!~ OR PROPOSED DISCHARGE. IF YES ATTACH A COPY OF. 1HE REPORT, DISCHARGE I c.

INFORMATION . ARE YOU REQUEST!~ AN EXEMPTION FRa1 SIB'llTTI~ A HY!l<<lGEOLOGICAL REPORT UNDER RULE R.323.ffz (~(P~E !IQ) OR FRa-1 GROLtlIMATER l'DNITORI~ 6EOO}iREMENTS UNDER RULE R. 23, ( ) lPAGE ':fl) OF 1HE PART Z2 RULES, IF 'YES ATTACH DYES *D oo 00Cll1ENTS AND EXPLANATION TO DE1-DNSTRATE lHAT YO~ DISCHARGE hoouJ QUALIFY FOR AN EXEl'l'-!ON,

n. ARE YOU REQUEST!~ A VARIANCE FRQ'1 RULE 323,Z2ffi (PJIGE ~) (OONDEGRADATION) OF 1HE WATER RESOLflCES aff!ISSION PART Z2 GRClUNll'IA~ RULES. IF YES, ATTAOi SOCH llOCU'1ENTS AS NECESSARY TO ~TE THE NEED FOR A VARI~ IN Tffi'IS OF T1£ DYES D oo CRITERIA SPECIFIED IN RULE , 0 (PAGE lj/) OF 1HE PART RULES, I

E. zlST ALL ~ICAL SlBST~S WHICH ARE lN MICHIGAN S CRITICAL MATERIALS REGISTER TABLE. IV Pl\GE 6) OR U,S, EPA S PRIORITY POLLUTANT LIST TABLE V (PAGE l) OR ANY OTHER SlmSTANCES llHICH ARE OR MAY BECO"E INJURICXJS TO n£ DESIGNATED USES OF THE GROLMW\TER OR 10 THE PUBLIC HEALTH lHAT ARE DISCHARGED OR EXPECTED 10 BE DIS~GED TO THE GROLtlIMATER/Y THIS D. NOT APPLICABLE/BELIEVED ABSENT FACILITY. ESTIMATE THE FINAL EFFLUENT CONCENTRATION mD RECCJID ALL DATA IN ITEM OF SECTION II IN THIS BOOIUT,

.*I THE APPLICANT MAY BE REaJIRED TO DO ADDITIONAL WASTE ANALYSES, D PRESENT, DATA PROVIDED IN ITEM ]

I'I A* DISCHARGE CHARACTERISTICS See Cover letteif AVE CONCENTRATION MAX UNITS* CODE # ANALYSES Sll/"i'LE TYPE CODE I

ITEM -socs for Elq>lanation (FIVE DAY BIOCHEMICAL OXYGEN DEMAND) IN IA I I* I I I I I I I I .. I I I I LlJ LLJ LJ 5 *con (CHEMICAL OXYGEN DEIWID) . - IN IA I I ,I I I I I I I I *1 I I I L1J LL...J LJ EXPECTED IN IA I , I I I I I I I I I LlJ L...LJ L_J WASTEWATER

  • roe (TOTAL ORGANIC CARBON) I I I I CHARAC- *>>M>NIA NllROGEN (AS N) IN lb: I I ;I I I I I I I I *I I I I Ll.J LJ_j. LJ TERISTICS ..

.TOTAL SUSPENDED SOLIDS !N 1A I I *I I I I I I I I , I I I I Ll.J. LLJ L_J UN1TS CODE TOTAL PHOSPHORUS (AS P) 1N 1A I I *I I I I I I I I , I I I -1 L1J LLJ - L_J 1 Mg/I r';

'j 2 Ug/I TOTAL RESIDUAL CHLORINE 1N1A I I .1 I I I I I I I 'I I. I I LlJ L.u L.J

..'i! 3 COUNTS/

i 100 ml DISSOLVED OXYGEN MIN 1N 1A I I ,I I I I I I I I 'I I I I LlJ L.J.:._J. L.J 4 s.u. *pH L..LiJ ~ ~ L..J..1J .~ LlU l._LJ L.J 5 °F 6 LBS/DAY FECAL COLIFORM BACTERIA 1N 1A I I I I I I I I I I LlJ L....LJ. LJ LR.i!..J . LJ LLJ, L_J L2J LL.I . L.J

~ERAME (SUMMER)

  • TEMPERATURE .(WINTER) ili..i.!..J . L.J. L...L....J .* L.J L2J L.._L_J L.J B, OTHER WASTEWATER ~CTERISTICS 1 o!IILl&IGIRIEIAISIEI I 1N1A1 I, I I I I I I I I, I I I I LJ LL.J LJ SAMPLE. I I I I I. I I I I I I I I I I I , I I I I I I I I, I I I I LJ L.L...J. LJ

.ll&..

1 GRAB I I I I I I I I I I I I I I I I .I I I I I I I I* I I I I LJ L.L...J LJ

-.i 2 24 HOUR I I I I I I I I I I I I I* I I I , I I I I I I I I , I I I I LJ L..L.J LJ COMPOSITE I I I I I I I I I I I 1* I I I I *I I I I I I I I , I I I I LJ LLJ . L_J I I I I I I I I r I I I I I I I , I I I I I I I I , I I I I LJ L.L..J L.J I I I I I I I I I I I I I I I I , I I. I I I I I I

  • I I I I LJ L.LJ L_J

~EQUIRED INFOR'1ATIO'I F~ SURFACE WATER DISCHARGES.

35

I 0

.. *s.~E INSTRUCTIONS ON* REVERSE* SIDE

-SECTION II PERMIT- ...

NUMBEI-. _

MI0049131 I

OJTFALL NUMBER IQ 1Q I~ I ITEM THE FOLLOWING REQUESTED INFORMATION~ ADOOESSED lrl..& SURFACE WATER DISCHARGERS, OOIE! NEW USE DISCHARGERS ~PROVIDE EXPECTED VALUES FOR THE QUANTITATIVE AND .

6 QUALITATIVE INFORM<\TION REQUESTED BELCM, A, IS THIS FACILITY A PRIMARY INDUSTRY?

(IF NO, GO TO E) (IF YES, GO TO B)

(REFER TO TABLE IA PA\,E 91)

!!] YES o*NO PRIORITY B, INDICATE TYPE OF PRIMARY INDUSTRY AS LISTED IN TABLE IA PA\,E !!l.

POLLUTANTS (CONTINUE WITH C,)

  • s r 1 1 ~ ~ l! 1E1L 1E ~ I I I I c.

AND ADDITIONAL DOES THIS OUTFALL DISCHARGE CONTAIN ANY PROCESS WASTEWATER?

(IF NO, GO TO E) (IF YES, GO TO D) []YES D NO INFORMATION D. I ND I CATE WHICH Ge/MS FRACTIONS MUST BE TESTED FOR ,

FOR (REFER TO TABLE IA PAGE !11) [] VOLATILE r:m:E! FOR EACH Ge/MS FRACTION CHECKED, EACH SPECIFIC ORGANIC TOXIC POLLUTANT WITHIN SURFACE WATER EACH FRACTION l:!l!fil BE ANALYZED FOR (SEE TABLE rIA PAGE !J2.. IN ADDITION, ALL PRll-'ARY

!NO.JSTRY APPLICANTS WITH A PROCESS WASTEWATER DISCHARGE"r;iUST PROVIDE QUANTITATIVE DATA FOR EACH TOXIC POLLUTANT IN TABLE lllA PAriE !13.) , -

D WE/NEUTRAL DISCHARGE ONLY RECORD ALL DATA ON FORMS PROVIDED ( ITEM 7) IN THIS BOOKLET *. D ACID (CONTIMJE WITH E-K BELOW)

D PESTICIDE E. IF .Nit. SURFACE WATER DISCHARGE APPLICANT (PRIMARY OR SECONDARY INO.JSTRY), REGARDLESS OF THE TYPE OF DISCHARGE, KNOWS OR HAS REASON TO BELIEVE THAT MN POLLUTANT. LISTED IN TABLE I IA AND IVA PAGES 42-43 IS DISCHARGED FRCJ-1 ANY OUTFALL.. THE QUANTITATIVE DATA D NOT APPLICABLEIBELIEVED ABSENT l:llJil BE PROVIDED, 7)

~

RECORD ALL DATA ON FORMS PROVIDED (ITEM IN THIS BOOKLET.

PRESENTiDATA IS ATTACHED F, IF ANY SURFACE WATER DISCHARGE APPLICANT (PRIMARY OR SECONDARY INO.JSTRY), REGARDLESS OF TYPE OF DISCHARGE, KNOWS OR tiAS REASON TO. BELIEVE ANY POLLUTANTS LISTED IN TABLE VA PAGE 43 A~E D!SCHAR(;ED FRCM ANY OUTFALL THE APPLICANT !1!fil DESCRIBE D NOT APPUCABLEfBELIEVED ABSENT REASONS FOR THE POLLUTANT BEING PRESENT AND PROVIDE ANY AVAILABLE QUANTITATIVE DATA, Xylene*

RECORD ALL DATA ON FOIO'IS PROVIDED (ITEM 7) IN THIS BOOKLET,

[] PRESENT/DATA IS ATTACHED G, ALL SLRFACE WATER DISCHARGE APPLICANTS (PRIMARY AND SECONDARY !NDUSTRI ES)

Wl-0:

USES OR MNUFACTURES 2, 4, 5 - TRICHLDROPHENOXY ACETIC ACID (2, 4, 5-T); ~ NOT APPLI CABLE/BELi EYED ABSENT 2-(2, 4, 5-TRJCHLDROPHENOXYl PROPANOIC ACID (SILVEX, 2, 4, 5, TP)j 2-(2, 4, 5-TRICHLOROPHEOOXY ETHYL 2, 2-DICHLOROPROPIONATE (ERBON ; 0,

~DIMETHYL Q-(2, 4, 5-TRICHLDROPHENYL) PHOSPHOROTHIOATE (RONNEL);

4, 5-TRICHLOROPHEOOL (TCP); OR HEXACHLOROPHENE (HCP); (ALL DATA FOR THE ABOVE MUST BE GENERATED USING STANDARD ANALYTICAL CALIBRATION PROCEDLRES) OR KNOWS OR HAS REASON TO BELIEVE THAT TCDD IS OR MAY BE PRESENT IN THEIR DISCHARGE, MUST REPORT t;lJAL!TATIVE DATA, GENERATED WHI~ USED A SCREENING PROCEDLRE NOT CALIBRATED WITH ANALYTICAL STANDARDS, FOR 2, , 7, 8, - TETRACHLORODIBENZO-P--DIOXIN D PRESENT/DATA IS ATTACHED (TCDD), RECORD ALL DATA ON FOOO PROVIDED (ITEM 7) IN THIS BOOKLET, J, IF THE SURFACE WATER DISCHARGE APPLICANT KMJWS OR HAS REASON TO BELIEVE THAT BIOLOGI~ TOXICITY TESTS WERE MADE IN THE LAST THREE C5) YEARS ON ANY OF THE APPLICANT S DISCHARGES OR ON A RECEIVING WATER IN RELATION TO A DISCHARGE, PROVIDE EJ OOT APPL! CABLE THl3 INFORW\TION AS AN ATTACH-18'1T TO THIS APPLICATION.

D APPLICABLE/SEE ATTACHED K. IF A CONTRACT LABORATORY OR CONSULTING FIRM PERFORMED ANY OF THE ANLAYSES REQUIRED BY THIS APPLICATION, PROVIDE THE NAME AND ADDRESS OF EACH LABORATORY OR FIRM AND [!] OOT APPLICABLE THE ANALYSES PERFORMED AS AN ATTACJ-MENT OF THIS APPLICATION, D APPLICABLE/SEE ATTACHED L. DO YOU DISCHARGg ANY OTHER TOXIC OR INJURIOUS CHEMICAL SUBSTANCES NOT LISTED IN TABLES IV PAGE _ AND I IA TI-fl0ty;H VA PA<;ES 42-43, 11= YES, THEN IDENTil=Y THE CHEMICAL SUBSTANCES AND ESTIMATE THE FINAL EFFLUENT CONCENTRATIONS, SUBMIT THIS D OOT APPL! CABLE CIS~l,2-Dichloroethene*

li'<FO~TION AS AN ATIACl-MENT TO THIS APPLICATION, EJ APPLICABLE/SEE ATTACHED

  • See attached letter to the Plainwell SWQD dated September 14, 1993.

37

SECTIQN,11.

SEE INSTRUCTIONS ic. ON REVERSE SIDE e PER.

NUM - ~ I MI0049131 I

~

OOTFALl rtnER 10 iQ fr. I ITEM A; USE THIS DATA SHEET TO RECORD INFCJRl.'ATION AS REGl.llRED IN: (QiECK APPROPRIATE BOX FOR WHICH JNFCJRl.'ATION THIS DATA SHEET REPRESENTS.)

7 D 1. SECTION II, ITEM 4::E* GRO~TER DISOlARGE INFOR1ATION (PAGE 55)

CRITICAL MATERIALS

[] 2. SECTION 11, ITEM *5, r

PRIORITY POl.lllTANTS IN SURFACE WATER DISCHARGE (PAGE 'ST)

TOXIC ~ 3. B. BELOW: cRITICAL MATERIALS (TABLE IV) IN SURFACE WATER DISOiARGE (PAGE 39)

POLLUTANTS o*

HAZARDOUS SUBSTANCES B. LIST Am CRITICAL MATERIAL (TABLE IV PAGE 6) NOT AD!JlESSED IN SECTION II ITEM f' PRIORITY OOT APPLICABLE.

POU.UTANTS hHIOl YOU mlW OR HAVE REASON TO BELIEVE TO BE PRESENT IN THE DISCHARGE
  • SEE IN REVERSE SIDE OF THIS PAGE FOR F\JllTI£R DIRECTIONS.

- DISCHARGE [iJ APPLICABLE (see BEl..()I)

..J A, ~ OF CRITICAL MATERIAL OR PRIORITY POLLUTANT Tetrachloroethylene. 11 t I- 11 ~ 1-1 4 I

,*, a:. UNIT CODE SAMPLE TYPE # OF ANALYSES w ....

ti

a. AVERAGE COOCENTRATION; SAMPLE TYPE; #OF ANALYSES I I 121 . I 21 I I w UNl:'2.CODE i..lJ t.l.JL
E c. MAXIMLM CONCENTRATION Mfl MASS I ,1 ,9 I
  • I lr I I t.=...J I I . I 0I
  • I0 11 16 I UN~DE

..J C[

A. NllME OF CRITICAL MATERIAL OR PRIORITY POLLUTANT Trichloroethylene_ 17 19 1-10 11 I--- I 6 I ii: uN12coDe SAMf>11_ TYPE. #OF ~YSES

\.

WN ti B. AVERAGE CCl>ICENTRATION; SA'1PLE lYPE; #OF ANALYSES I I 131. I 01 I I i..=..J L..:J . LL!=...J

E c. MAXIM COOCENTRATION AND-MASS I 12 10 I .~ I I I

UNIT cooe .

2 1.£.J I I I

01. I 0 1117 I UN1l50DE UNITS CODE ..J C[

A, NN1E OF CRITICAL MATERIAL OR PRIORITY POWITANT Xylene I I I I I I I I 1 Mg/I iC UNIT CODE SA/>'PLE. TYPE #OF ANALYSES 2 Ug/I WM ti B. AVERAGE COO:ENTRATION; SA'll'LE TYPE; fl OF ANALYSES I I IO I . 12 I I I w UNIT CODE Li"-~ I i

3 LBS/DAY :E UNIJ CODE

c. MAXll'U1 CONCENTRATION AND. MASS I I 1l I
  • I 01 I I dJ I I I 0I *I 0 I 0 14-1 ~- I 4 KG/DAY

..J C[

A* NllME OF CRITICAL MATERIAL OR PRIORITY POWITANT CIS-1 9 2-Dichloroethene I I I I I **1 I I iC 9, AVERAGE CONCENTRATION; SN1PLE TYPE; # OF ANALYSES UNIT{CDE . . sN1PGPe # '(5 :'r1;YSES :

Wot I I I 0 I . 12 I I I L£.J ~**

ti UNITF,E

E c. MAXIM COM:ENTRATIOO AND MASS 0 -0 0 4 UN13coDE I I I l 1
  • 10 I I I L=..J I I I I *I I I I t=...J SAMPLE TYPE ..J s A* rwE OF CRITICAL MATERIAL OR PRIORITY POLLUTANT I I I I I '1 .. ,' I 1 GRAB a:
  • , UNIT CODE SA'lPLE TYPE # OF .ANALYSES
    • ' 2 24HR.COMP. Wll) a. AVERAGE CONCENTRATION; SAl'l'LE TYPE; # OF ANALYSES I I I I. I I I I LJ LJ 'L_1_J ..

ti

E c. UNIT CODE ll>IIT CODE MAXll"U>I COOCENTRATION Mfl MASS I. I I. I I I I I *I I L.J I I I I. I I LJ

..J A* NllME OF CRITICAL MATERIAL OR PRIORITY POLLUTANT I I I I - . I *1 I I C[

iC UNIT CODE S>>f'LE TYPE 7f OF ANALYSES WCD a. AVERAGE COOCENTRATION; SAMPLE TYPE; fl OF ANALYSES I I I I .I I I I LJ L_J L_1_J ti

E c. MAXll'lfl *m<<:ENTRATIOO AM:> MASS I I I I *I I I I UNIT CODE L.J ,. I I I .'1* .I I I ll>IIT CODE Ll

... ..J C[

.~ . NA'1E OF CRITICAL MATERIAL OR -PRIORITY POLLUTANT . I I I I 1* I I I iC ~IT CODE . SA'1PLE TYPE #OF ANALYSES wr-- B. AVERAGE CONCENTRATION; SAMPLE TYPE; # OF ANALYSES

~

I I I I.I I I I LJ L.J LL..J

E ll>IIT CODE ll>llT CODE
c. MAXIM COOCENTRATION AND MASS I I I I
  • I I I I L.J I I I I* I I I I LJ

..J A* NAME OF CRITICAL MATERIAL OR PRIORITY POLLUTANT I I I I I I I I cc ccWal 3, AVFFAGE CONCENTRATION; SAMPLE TYPE;.# OF ANALYSES UNIT CODE 5N'1PLE lYPE 11 OF ANALYSES I-C[

I I I I. I I I I LJ LJ L.LJ

ii UNIT CODE UNIT CODE
c. WIXIMl.1'1 CONCENTRATION AND MASS ( I I I
  • I I I I L.J I I I I* I I I I LJ ADDITIOOAI.. PAGES OF THIS ITEM 7 ARE ATTAO£D FOR THE REST OF 11-iE CRITICAL *Q YES MATERIALS NID/ai. PRl<Xl.ITY POU.UTANTS REWIRED TO BE REPORTED, Qg NO 39

consumers Power.

POWERIN&

MICHlliAN'S PROliRESS General Offices: 212 West Michigan Avenue, Jackson. Ml 49201 * (517) 788-0550 September 14, 1993 21E01M90518.6 Mr Fred Morley.

District Supervisor Surface Water Quality Div Michigan Department of Natural Resources Plainwell District Office Bldg 621 North Kent St PO Box 355 Plainwell, MI 49080 Re: PALISADES PLANT NPDEs* PERMIT.NO MI0049131 In response to the special conditions of the Palisades Plant NPDES Permit No MI0049131 (Section A.2.3.b), we have recently detected other chemicals in the groundwater which were not list~d in the NPDES permit application. The attached analytical results indicate that trace concentrations (<2ug/1) of x_ylen_~_.an-9_ cis-1,2- QJ~hloro_ethene are present in the water from extraction wells EW-1 and EW-2. This water*-is pumped through an air stripper tower to remove the previously identified chemicals (tetrachloroethene and

  • trichloroethene) prior to discharge at outfall 001. Based on the analytical results for the system effluent (sample SC-6GW), both of these additional chemicals are being removed in the stripper. Since tha contentration of xylene and dichlorethene in the groundwater are well below the MDNR's Type B health based drinking water limit of 13,000 ug/l and 77ug/l, respectively, it would not be necessary to modify the NPDES permit.. Should these groundwater chemical concentrations increase beyond the cleanup limits, your office will be notified accordingly.

If you have any questi-0ns concerning this matter, please contact me at (517) 788-2980.

Sincerely David A Olsen, P.E.

Environmental and Technical Services 00993-07.DAO A Gt-f5 N~GY COMPANY

\

TABLE-A 1. ANALYTICAL RESULTS e *. CONSUAIERSPOKEIH;t,.._NY .

" Environmental & TllChnicaJ;Setvices Department

!LOCATION IPALISADES PLANT I Project Number

\ 1- Groundwater Treatment System i CHEM-93-1953

\Sample ldentfflcation Sample Type Sample Date Received Date I Analysis Date I Report Date Control Number SCAN 602, ug/L - 8021  ::::: .+* '<;:::);i,r:>*:>:::;:;;!V:;,:::<::.,)::))j:)::::::,*:.::;*::. :::c::/> ::.... ? ..:.;.j*.::.:;'::,/::::'.i:I TMDL.

Benzene nd nd nd nd nd . 1 Toluene nd nd nd nd Ind 1 Ethylbenzene nd nd rid nd nd 1 m/p-Xylene nd nd . nd nd nd 1 a-Xylene nd nd nd nd nd 1 Surrogate Recovery %Recovery %Recovery I% Recovery % Recovery I% Recovery 4-Bromofluorobenzene - 97 96 96 . 98 97 I

.*I *I I

\

~i.

I NOTES: TMDL = Target Method Detection Limit, ug/L (parts-per-billion) nd = Parameter Not Detected At TMDL I Reviewed By

  • Date a?ffdff/:1 I Data Fiie 931953

','.*f_

-'-~ ,,

-:"T?_".=_""T-<::

.. -~ .*-~ _i'. -*~:-- .-

~-.JC,_,_

... _* ~ , ... '""\

. e TABLE A2.. ANALYTICAL RESULTS

.. CONSUllERSPOWERcoU*

EnvironmsntaJ & TtJChnlcaJ SsrAces. Osparf!nfmt

" _~- *-..... .........

!LOCATK>N .PALJSADES PLANT Project Number

l. - Groundwater Treatment System CHEM-93-1953 Sample Identification ISVE ISC-3GW SC-6GW-fr+ SC-3GW
  • SC-6GW#

II 1 1 I 1 L**qu1'd 0750hr 0740hr jl0710hr.

  • 0705hr J Sample Type jwater . 1water I

water water water j

\ Sample Date 09-03-93 109-04-93 09-04-93 Og:..()5-93 09--05-93 i Received Date 09-07-93 J09-07-93 09-07-93 09-07-93 09-07-93.

I Analysis Date 09-07-93 '09--07-93 09-07-93 09-07-93 09-07-93 Report Date 09-07-93 09--07-93 09-07-93 09-07-93 09-07-93 Control Number 931953-01 931953-02 ,931953-03 931953-05 931953-04 SCAN 601, ug/L - 8021 Bromoform nd nd nd nd nd 1 Bromomethane nd nd nd nd nd 1 I Carbon Tetrachloride 1~:

nd nd nd nd 1

\ Chlorobenzene nd nd nd nd 1 1

Chloroethane
  • nd nd nd nd nd 1 I 2-Chloroethylvinyl Ether nd Ind nd nd nd 1 I Chloroform I

nd ,Jnd nd nd nd 1 I Chloromethane 'nd Ind nd nd nd 1 Dibromochloromethane nd l~d nd nd nd 1 1,2-Dichlorobenzene nd nd nd nd nd 1 1,3-0ichlorobenzene nd nd nd nd nd 1 1,4-Dlchlorobenzene nd nd nd nd nd 1 I Dichlorodifluoromethane Ind ,nd nd nd nd I 1, 1-Dichloroethane ind nd

.,,1 nd nd nd 1,2-Dichloroethane Ind nd nd nd nd 1 cis-1,2-Dlch loroeth ene 1.0 1.3 nd 0.7 nd 1 trans-1,2-Dlchloroethene nd nd nd nd nd 1 1,2-Dichloropropane nd nd nd nd nd 1 cis-1,2-Dich loropropene *nd nd 1

nd 1 nd nd I 1 trans-1 ,2-Dlchloropropene nd Ind nd nd nd II 1 I

Methylene Chloride nd nd nd nd nd i 1 1, 1, 1,2-Tetrachloraethane nd nd nd nd

  • nd 1 1, 1,2,2-Tetrachloroethane Tetrach loroethene Ind 20.5 nd 17.1 nd 0.4 nd 42.8 nd 0.3 I 1 1

1, 1, 1-Trich loroethane nd nd nd nd nd 1 1, 1,2-Trichloroethane nd nd nd nd nd 1 Trichloroethane 10.3 59.8 10.1 0.7 1 Trich lorofluoromethane nd nd nd nd nd 1 Vinyl Chloride nd nd. nd nd nd 1 Surrogate Recovery  % Recovery  % Recovery  % Recovery Bromoch loromethane 86 I 85 85 86 85 2:....eromo-1-chlorpropane 96 I 96 95 96 97 4-Bromofluorobenzene 98 I 98 97 98 98

'NOTES: TMDL =- Target Method Detection limit, ug/L (parts-per-billion) nd = Parameter Not Detected At TMDL I Reviewed By Date Data File 931953

-A2.-

r= '2.. D k \-...l ' I.. I... ':

, (~~~E~1. ANALYTICAL RES.S

  • ~

"' EhvlronmentaJ.&* Technlcal.S.~ ~nt~* :  ;,,

r.1L~OC:-=:~=~~-iSlN=.::-------------~P~A-U-SAD---E-S_P_l.ANT

_________________________-r-P~r-~-eci __N_u_m_b_er-.-----.

- Groundwater Treatment stem- CHEM-93-1953 Sampte. ldentlflcation ISC-3GW ~W SC-OOW SC-&GW Method

..*...*. 1910hr. .1920hr 0630hr 0640hr: Blank Sample Type . 1water water water w~ter water Sample Date 09-0S:-93 09-06-93 09-06-93 09-06-93'

.' -~

Received Date 09-07-93 09-07-93 09-07-93 09-07-93 Analysis Date 09-07-93 .10~7-93 09-07-93 09-07-93 09-07-93

'.-~*

  • ' Report Date 09-08-93 09-08-93 09-08-93 09-08-93 09-08-93 Control Number 931953-06 931953-07 931953=-08 931953-09 931953-MB I
  • j SCAN 602, ug/L - 8021
  • ,,_ nd nd Benzene nd nd nd Toluene nd nd n~ nd nd Ethyfbenzene nd* nd nd nd nd m/p-Xylene nd nd nd nd nd o-X lene nd nd nd nd nd Surrogate Recovery  % Recovery % Recovery % Recovery  % Recovery  % Recovery 4-Bromofluorobenzene 98 98 96 95 98 i
  • i NOTES: TMDL = Target Method Detection Limit. ug/L (parts-per-billion) nd
  • Parameter Not Detected At TMDL Reviewed B Date 0 7 °?.?-f Data Ale 931953*

~~~~E 92.. ANALYTICAL AES-S CONSUllERS.FOKER COML,.

  • Environmental & TtH:hnlclll SslYit:eS oS,,.rtrnent LOCATION PALISADES PLANT Project Number

- Groundwater Treatment System- CHEM-93-1963 Sample Identification SC-3GW SC-6GW SC-3GW ~w . Method 1910hr 1920hr 0630hr 0640hr Blank Sample Type water water water water 1water Sample Date 09-05-93 09-05-93 09-06-93 09-06-93 Received Date 09-07-93 Og,...()7-93 09-07-93 09-07-93 Analysis Date 09-07-93 09-07-93 09-07-93 o9-o7-93 09-07-93 Report Date 09-08-93 09-08-93 09-08-93 09-08-93 09-08-93 Control Number 931953-06 931953-07 931953-08 931953-09 931953-MB SCAN 601, ug/L-8021 TMDL Bromoform nd nd nd nd nd 1 Bromomethane nd nd nd nd. lid 1 Carbon Tetrachloride nd nd nd nd nd 1 Chlorobenzene nd nd nd nd nd 1 Chloroethane nd nd nd nd nd 1 2-Chloroethylvinyl Ether nd nd nd nd nd 1 Chloroform nd nd nd nd

  • nd 1 Chloromethane nd - *nd nd nd nd 1 Dibromochloromethane nd nd nd nd nd 1 1,2-Dlchlorobenzene nd nd nd. nd nd *1 1,3-Dlchlorobenzene nd nd nd nd nd . 1 1,4-0lchlorobenzene
  • nd nd nd nd nd .1 Olchlorodifluoromethane nd nd nd nd nd .1 1, 1-Dlchloroethane nd nd nd nd nd 1 1,2-Dichloroethane
  • nd nd nd nd nd 1*

cls-1,2-Dlchloroethene 1.9 nd 0.5 nd nd 1 trans-1,2...Dichloroethene nd nd nd nd nd 1 1,2-Dlchloropropane nd nd nd nd nd 1' cis-1,2-Dichloropropene nd nd nd nd nd 1 trans-1,2-Dichloropropene nd nd nd nd nd 1 Methylene Chloride nd nd nd nd nd. 1 1, 1, 1,2-Tetrachloroethane nd nd nd nd nd 1 1, 1,2.2-Tetrachloroethane nd nd nd nd nd 1.

Tetrachloroethene 12.8 0.4 8.7 0.2 nd 1 1, 1, 1-Trichloroethane nd nd nd nd nd* .0 1 nd nd nd . *1 1, 1,2-Trichloroethane nd nd Trichloroethene: 46.6 1.0 33.3 .. 0.7 nd , ...** ,.,. 1.

Trichlorofluoromethane nd nd nd nd nd 1 Vinyl Chloride nd nd nd nd nd 1 Surrogate Recovery  % Recovery  % Recovery  % Recovery mmmmmmmm1mm Bromochloromethane 84 85 . 96 86 85 2-Bromo-1-chlorpropane 97 96 95 96 97 4-Bromofluorobenzene 99 98 98 97 98 NOTES: TMDL =- Target Method Detection Limit, ug/L(parts-per-billlon) nd - Parameter Not Detected At TMDL IReviewed By Date 0 7' cJ? P..7 I Data File 9319531

. e TABLEA1*. ANALYTICALAESULTS CONSU&fERsFm\EH~-,

EiivtronmentaJ & Technk:sl SBfvicBB.Ospartment- .

't-OCA---:no---N--------------------------------------.;._----------__,.,-P-ro_j_e-ct_N_u_m_b_e_r_:__

1

  • PALISADES PLANT

____,r i -Groundwater Treatment Svstem I CHEM-93-1973

Sample Identification !SC-1GW ISC-2GW 1~GW ISC-SGW
  • ISC-3GW I . I*

i :ew-1 Inlet IEW-21nlet Inlet Treated !Inlet

  • I I

l Sample Type jwater. I09-08-93 water water . water water I. :  : i:**::: ..

l'.i ;t){ :

j Sample Date 109-08-93 09-08-93. 09-08-93 09-07-93 I '.::.:::.:\./;:<

! Received Date 109-09-93 109-09-93. 09-09-93 109-09-93 09-09.:...93 IAnalysis Date 09-09-93 09-09-93 09-09-93 '09-09-93 09-09-93

' Report Date 09-10-93 09-10-93 09-10-93 09-10-93 09-10-93 Control Number 931973-01 931973-02 931973-03 . 931973-04 . 931973-06 I

SCAN e02, ug/L - 8021 Benzene nd nd nd nd nd 1 Toluene"

  • nd nd nd nd 1 Ind
  • nd nd nd Ethyfbenzene m/p-Xylene Ind 1.5 nd nd nd nd
  • 2.0 I 1 1

.a-Xylene I 1.1 nd nd nd 1.3 I 1

  • !Surrogate Recovery 1% Rec~ery  % Recovery  % Recovery  % Recovery 4-Bromofluorobenzene I 97. 98 98 96 I

.~

}

NOTES: TMDL = Target Method Detection Limit, ug/L (parts-per-billion) nd :s. Parameter Not Detected At TMDL Reviewed By cJ Date /) Z-/d-f"-? Data File 931973

-A1-

TABLEA2 *. ANALYTICALRESULTS e . . . .

COHSUAIERsPOKE1H~OA,e.<< * ..* .

Environmental.&.c Tiichnlcal Services Department"' .

. ----- ~

LOCATION i

.PALISADES PLANr j Project Number

- Groundwater Treatment System CHEM-93-1973 Sample Identification ,se-1aw ISC-2GW SC-3GW . se-.6GW . SC-3GW F:W-1 Inlet :EW-2 Inlet Inlet Treated /inlet

! Sample Type water :water water water water I

Sample Date 09-08-93. j09-08-93 09-08-93 09-08-93 09-07-93 Received Date .09-09-93 109-09-93 09-09-93 09-09-93 09-09-93 Analysis Date 1 09-09-93 I09-09-93 09-09-93 0,9-09-93 09-09-93 Report Date 09-10-93 j09-10-93 09-10-93 09-10._93 09-10-93 Control Number 931973-01 !93.1973-02 931973-03 931973-04 . 931973-05 SCAN 601, ug/l-8021 .j[:i)::::j::H~;H:(\}H (\:\' *,* <::~:~'./(: TMOL Bromoform nd nd 1 Bromomethane i"dnd l"d nd Ind nd

  • l"d nd 1 Carbon Tetrachloride nd Ind nd nd nd 1 Chlorobenzene nd Ind nd. nd nd 1 Chloroethane nd *nd . nd nd nd 1 2-Chloroethylvinyl Ether. nd !nd nd nd nd 1 Chloroform nd ind nd nd nd 1 I

1 Ch/oromethane nd I.nd nd nd nd 1 Dibromochloromethane nd !nd nd nd nd 1 1,2-Dlchlorobenzene nd nd nd nd nd 1 1,3-0lchlorobenzene nd nd nd nd nd 1 1,4-0lchlorobenzene nd nd nd nd nd .. 1 Dichlorodlfluoromethane nd nd nd nd nd 1 1, 1-0ichloroethane nd nd nd nd nd '1 1,2-0ichloroethane nd 1nd nd nd nd 1 cls-1,2-0lch/oroethene 0.1 I 1.5 L1 nd 0.7 1 trans-1,2-0ichloroethene nd Ind nd nd nd 1 I 1,2-0ichloropropane nd nd nd nd nd 1 I cis-1,2-Dlchloropropene nd nd nd nd nd 1 I trans-1,2-Dlch loropropene nd nd nd nd nd 1 Methylene Chloride nd nd nd nd* 1 Ind 1, 1, 1,2-Tetrachloroethane nd nd nd nd

  • nd 1 1, 1,2,2-Tetrachlorcethane nd Ind nd nd nd 1 Tetrachloroethene 6.7 I 57.5 24.9 1.7 6.5 1 1, 1, 1-Trichloroethane nd nd nd nd nd 1 1, 1,2-Trichloroethane nd nd nd nd nd .1 Trichloroethane . 23.9 . 6.1 13.3 1.3: 22.1 1

,. Trichlorofluoromethane nd nd nd nd nd *1 Vinyl Chloride nd nd nd nd nd Surrogate Recovery  % Recovery % Recovery % Recovery % Recovery % Recovery Bromochloromethane 83 85 85 84 81 2-Bromo-1-ch lorpropane 4-Bromofluorobenzene NOTES:

! 96 98 96.

98 TMDL .. Target Method Detection Limit, ug/L (parts-per-billion) 96 97 96 97 nd .. Parameter Not Detected At TMDL Date Data File 931973

-A2.-

TABlEB1.

. e * . CONSUMERs:POM:R*coM**"*

ANALYTICAL.RESULTS~ ..

Environmental:& TIH:lrnlcal SsfVioes-,Oepartmsnt ::*..

. ~*

LOCATION PALISADES PLANT.

- Groundwater*neatment System Project Number CHEM-93-1973

.**,*I:.

!Sample Identification* jSC-6GW Method 1. *=.:.;*:*.*

Treated Blank.  ::_:;_:*:;

Sample Type water . wat~r  :;:*:*:*.

SampleOate . 09-07-93.

Received Date 09-09-93 Analysis Date 09-09-93 09-09-93 Report Date 09-10-93 09-10-93 Control Number 931973-06 931973-mb SCAN 602, ug/L - 8021 Benzene nd nd 1 Toluene nd

  • nd 1 Ethylbenzene nd nd 1 m/p-Xylene
  • nd nd *t o-Xylene nd
  • nd * **t Surrogate Recovery  % Recovery 4-Bromofluorobenzene "98

. :~

NOTES: TMDL ... Target Method Detection Limit, ug/L (parts-per-billion) 7"'***

I .

nd = Parameter Not Detected At TM DL IReviewed By

  • Date Cl f?<<.'.2 ?Z-J I Data. File 931973

\,....- j TABLE 132** ANALYTICALRESULTS*

e *- . CONSUMERS.POKER.~"*** ....

Eiivrmnmental &.TBchnlcaJSSIVfces1Uflplll'tmflnt'* * .. *

~-~-

LOCATION PALISADES PLANT Project Numb~r* 1.

- Groundwater Treatment System CHEM-93-1973 Sample ldentiflcatlon SC-6GW Treated

!* Method ...: *. :/ ~-:;::~:j'l'.\;'.*

j_ Blank *** *.*.*******:::

Sample Type water i water .:** *. :::::::'.)?;:<

I Sample Date 09-07-93  ;  :"'::';:_:*.:\*

I E!~b :;1 ~*,~:1 ~1i ~. *

~eceived Date .09-09-93 i AnaJysis Date 09-09-93 II Report Date I Control Number 09-10-93 931973-06 I' ,

jSCAN 601, ug/L - 8021 ***; :.. * :*:: ...

  • 1* .* .. :>'.'/'(i;~;;:\:1i~:m :mm~m:::::~:;?)Ht: TMDL

! Bromoform nd nd 1*

l****

I Bromomethane nd I nd 1 I Carbon Tetrachloride** nd I nd 1 Chlorobenzene nd I nd 1 I Chloroethane

  • nd I nd 1 2-Chloroethylvinyl Ether nd nd 1 Chloroform nd I nd 1 Chloromethane nd nd 1 Dibromochloromethane nd nd 1 1,2-0lchlorobenzene nd nd 1 1,3-0lchlorobenzene nd nd 1 1,4-Dlchlorobenzene nd
  • nd 1 Dich lorodifluoromethane nd nd 1 1, 1-0lchloroethane nd nd .. ~1 1,2-0ichloroethane nd nd t I cls-1 ,2-Dichloroethene nd nd 1 I trans-1,2-Dichloroethene nd I nd 1 11,2-0lchloropropane . nd* I nd 1 cis-1,2-Dichloropropene . nd nd 1 I trans-1,2-Dlchloropropene nd I nd 1 Methylene Chloride nd nd 1 1, 1, 1,2-Tetrachloroethane nd nd 1 1, 1,2,2-Tetrachloroethane nd nd 1 Tetrachloroethene 0.4 nd 1 1, 1, 1-Trichloroethane nd nd 1 1, 1,2....Trichloroethane nd nd 1 Trichloroethane 0.8
  • nd 1 Trichlorofluoromethane nd * -~ nd 1*

Vin I Chloride nd nd Surrogate Recovery  % Recovery  % Recovery Bromochloromethane *a2 86 2-Bromo-1-chlorpropane 91 96 4-Bromofluorobenzene 95 98 NOTES: TMDL - Target Method Detection Limit, ug/L (parts-per-billion) nd =-* Parameter Not Detected At TMDL Reviewed B Date 6 Data File 931973 TABLE:A2~ ANALYTICAL.RESULTS:

~

~-

_{.

~ .......

-*~*

~
1-iLOCATJON .  ;

<; PALISADES Pl.ANT

i -Groundwaterneatment Syatenr

~ ,.,

. Sample ldenihcation . SC-1GW SC-2GW. SC-3GW 1

Sample Type water water water water . water*

~{

.q Sample Date 09-09-93 09-09-93. I 09-09-93' 09-09-93: ~.~((*: ~;

} ':

  • ~~

\,*

Received Date 09-10-93 0~10~. 09-10-93: 09-10-:93 ; .. -* ~-*..,* . <;

./

Analysis Date 109-10-93

  • 09-1 o-93 : 09-1 o-93 ..

.I*

. -; 09-10-93 09-10-93 l *. ..-**

., .. Report Date* 09-10-93 09-10-93' 09-10-93 09-10-93 . 09-10-93 . .

l Control Number 931984-01 931984-02 1931984-03 931984-04 . 931984-mb

-.~ SCAN 801, ug/L-8021
  • ~:'

.,_~ Bromoform* nd nd* nd nd . nd *** . .

.. .,: Bromomethane . nd nd nd nd nd

\J Carbon Tetrachloride * " , . nd nd nd nd **<: ~ nd*

-~:

Chlorobenzene nd nd nd nd nd

'.;:. Chloroethane nd nd nd nd nd 2-Chloroethylvinyl Ether nd nd nd nd

\'*

. Chloroform nd nd nd nd

'~ Chloromethane . nd nd nd nd

  • -:~

~ ,.~ Dlbromochloromethane nd nd nd nd

--~

.:.) 1,2,.....Dlchlorobenzene nd nd nd nd 1"

1,~ichlorobenzene nd nd nd nd

  • 1,4-Dlchlorobenzene nd nd nd* ..

nd 1;;

  • ':J Dlchlorodlfluoromethane -* nd nd nd _nd
  • ~

r':; 1,1-Dlchloroethane-..* .. : . nd nd nd nd.

'j:~

'~I 1,2.-0ichlo;oetil~'~,*-~ ?' _.*; .. nd

~:-. ~"..;

nd

- /:.

- nd d

.cls-1,2-Dlchloreeth~*,;~ \,. '., c*

f ~

0.6 1~2* *1'.1' nd

~ trans-1,2..;.olchloroethene
  • nd* nd nd nd

-~;

1,; 1,2-Dlchloropropane nd nd nd nd

~-

cis-1,2-Dlchloropropene nd nd nd nd

'. *trans-1,2-Dlchloropropene nd nd nd nd

,;:~.. Methylene Chloride' * . : nd nd nd nd

..'1 nd nd nd nd It~

nd nd. nd nd i  : 8.1 35.5 i*J

...

  • nd nd nd nd
  • j r {.: nd. nd 5~8 nd

_15;4 nd

~

  • . 28.4 ll'~'

nd.- *;*.\'_/.* nd' -,~,,,:\,: ';: nd.

1c:.

i{: nd nd nd nd **'

  • nd * *
  • 1*.1 r~*~ Surr0gate Recovery  % Recovery % Recovery* % Recovery % AecoVery % Recovery
\ .83 95* * * .: 88 "" ~*88 I Bromochloromethane 82 I'.;

.\! 2-Bromo-1-chlorpropane**  : 94 94 95 ,>"* .. _L,96' .-c:_,, ' 97' 1 4-Bromofluorobenzene 98 96 . 96 . . 98 . ... 95*

':i

'""- NOTES: TMDL *. Target Method Detection Limit; ug/L (parts~per-bllllon)

<' nd - Parameter Not Detected At TMDL Reviewed By

  • Date*C>Cf-/tJ-fJ. DataFlle 931984

-A2"!"'*

  • . ""' - '- e TABLE A 1. ANALYTICAL RESULTS CONSUllERSPOVER"COll9w*

Envimnmental & .TilchnlCal Sstvicllfl-Oipartment *

\LOCATION 'PALISADES PLANT Project Number

- Groundwater Treatment System CHEM-93-1984

\Sample ldentfficatlon SC-1 GW ISC-2GW SC-3GW Method

!::-::;. ,::::::::::I I

! Sample Type water . lwater water I Blank

._.:/'T_=:::{-;'.,=.

water water ... *;.****:=*.:.::*:<::::

Sample Date 1 .*.:

09-09-93 09-09-93 09-09-93 OS-o9-93 ...

i~ , '~1~ ~]~1~ ~

Received Date 09-10-93 09-10-93 09-10-93 09-10-93 Analysis Date 09-10-93 09-10-93 09-10-93 09-10-93 09-10-93 Report Date 09-10-93 09-10-93 09-10-93 09-10-93 09-10-93 Control Number 931984-01 93i984-02 931984-03 931984-04

  • 931984-mb SCAN 602, ug/l - 8021  :::1!::i:::::)i(; *:** ::) ~::::: =.:y,:y.::>:;::::;':: ~:;::::;:;:;: ,. ,_ ... ;;.::;,; ::,;;!::}:[:[:::;m::~\:+i:;: :w:::>*==* .\!Ud:!;iii;; TMDL Benzene nd nd nd nd  !"Id 1 I

Toluene nd nd nd nd nd 1 Ethylbenzene nd nd nd nd nd 1 m/p-Xylene 3.1 1.0. 1.0 nd nd 1 o-Xvlene 1.6 nd nd nd nd 1 Surrogate Recovery 4-Bromofluorobenzene NOTES: TMDL .. Target Method Detection Limit, ug/L (parts-per-billion) nd

  • Parameter Not Detected At TMDL Reviewed By Date c2 7-/ iJ ~ Data File 931984

-A1-