ML052000440

From kanterella
Jump to navigation Jump to search
Precedents for Section 3.5 Exceptions to GALL
ML052000440
Person / Time
Site: Palisades Entergy icon.png
Issue date: 04/01/2005
From:
- No Known Affiliation
To:
Office of Nuclear Reactor Regulation
Morgan M, NRR/DRIP/RLEP, 415-2232
Shared Package
ML052000229 List:
References
Download: ML052000440 (161)


Text

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing HELB Carbon Steel Plant Indoor Air Loss of Material Boric Acid Corrosion III.A3.2-a 3.5.1-20 580, III.B5-7 5-36 A, 580,

- Carbon Steel, Shielding (Ext) Program 584, H 584 Protected Pipe Whip (column, hanger, Restraint beam, truss, Shelter/

decking, floor Protection grating or plate, catwalk, Structural threaded Support for fastener, Non-Safety concrete Related expansion bolt, column base Structural Support for plate, weld, etc.)

Regulated Events Structural Support for Safety Related III.B5.1-b 3.5.1-31 583, A Structural Monitoring III.A3.2-a 3.5.1-20 580, A Program 1 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B5.1-a 3.5.1-31 A Building Framing Flood Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Concrete, Protection Below Grade Structural (wall footing, Support for foundation, slab, Safety grout, Related reinforcement, duct banks, cable pits, tunnels, etc.)

III.A3.1-g 3.5.1-21 544, A Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking None Required III.A3.1-h 3.5.1-25 547, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion 2 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking / Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl Building Framing Flood Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A

- Concrete, Protection Weather (Ext) Properties Program Exposed Missile Barrier (foundations, Radiation concrete &

Shielding masonry wall, beam, roof slab, Shelter/

grout, Protection reinforcements, Structural concrete around Support for expansion &

Safety grouted anchors)

Related III.A3.1-f 3.5.1-20 A Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Program III.A3.1-a 3.5.1-20 A III.A3.1-h 3.5.1-25 A 3 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 4 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Direct Flow Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A

- Concrete, (Ext) Program Fire Barrier Protected HELB (foundations, Shielding concrete &

masonry wall, Missile Barrier

column, pedestal, beam, Pipe Whip Restraint floor slab, grout, reinforcements, Radiation concrete around Shielding expansion &

grouted anchors, Shelter/

cable pits, Protection tunnels, etc.) Structural Support for Safety Related III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program 5 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Flood Barrier - Flood Carbon Steel Atmosphere/ Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, C Carbon Steel, Protection Weather (Ext) Program Exposed Structural (water tight Support for doors) Safety Related Flood Barrier - Flood Carbon Steel Plant Indoor Air Loss of Leak Structural Monitoring III.A3.2-a 3.5.1-20 531, H N/A N/A N/A Carbon Steel, Protection (Ext) Tightness Program Protected Structural (water tight Support for doors and gate) Safety Related 6 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 583, C Program Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program Fuel Related Structural Carbon Steel Plant Indoor Air Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 578, III.B2-9 5-33 E, 578, Component - Support for (Ext) 579, F 579 Carbon Steel, Safety Protected Related (anchor bolts for SFP gates, liners, transfer tube appurtenances Fuel Related Structural Stainless Steel Plant Indoor Air Cracking None Required III.A5.2-b 3.5.1-23 535, G N/A N/A N/A Component - Support for (Ext)

Stainless, Safety Protected Related (anchor bolts for SFP gates, liners, transfer tube appurtenances 7 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Fuel Related Expansion / Stainless Steel Treated Water Cracking None Required III.A5.2-b 3.5.1-23 535, E Component - Separation (Ext)

Stainless, Fluid Borated Pressure (liner plates, Boundary gates, transfer Structural tube expansion Support for bellows)

Safety Related Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 523, 578, A HELB/MELB Direct Flow Carbon Steel Plant Indoor Air Loss of Leak Structural Monitoring III.A3.2-a 3.5.1-20 532, H N/A N/A N/A Component - (Ext) Tightness Program Flood Carbon Steel, Protection Protected HELB (doors, scuttle, Shielding blowout panels, floor drains & Pipe Whip screens, guard Restraint pipes, louvers, whip restraints, bellows, spray shields, etc.)

8 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 583, C Program Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program HELB/MELB Flood Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Protection (Ext) Program

Concrete, HELB Protected Shielding (curbs & pipe Pipe Whip whip restraint Restraint grout, concrete at locations of Direct Flow expansion &

grouted anchors)

Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program 9 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program HVAC Fluid Stainless Steel Plant Indoor Air Cracking None Required III.A3.2-a 588, F N/A N/A N/A Component - Pressure (Ext)

Stainless, Boundary Protected Structural (Control Room Support for vestibule door) Safety Related HVAC Fluid Carbon Steel Plant Indoor Air Loss of Leak Structural Monitoring III.A3.2-a 3.5.1-20 533, H N/A N/A N/A Component - Pressure (Ext) Tightness Program Carbon Steel, Boundary Protected Structural (Control Room Support for vestibule door) Safety Related Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 583, C Program Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program 10 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HVAC Fluid Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Pressure (Ext) Program Concrete, Boundary Protected Structural (Control Room Support for vestibules, Safety concrete & Related masonry walls, floors, ceilings)

Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 11 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HVAC Fire Barrier Galvanized Plant Indoor Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 581, Component - (Ext) Program 583, C Structural Galvanized, Support for Protected Safety (damper & Related louver frames)

Structural Monitoring III.A3.2-a 3.5.1-20 581, C Program Missile Shield - Missile Barrier Carbon Steel Plant Indoor Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 583, C Carbon Steel, (Ext) Program Structural Protected Support for (steel doors and Safety structural steel Related missile barrier)

Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program 12 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Operator Access Structural Carbon Steel Plant Indoor Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 583, A Component - Support for (Ext) Program Carbon Steel, Non-Safety Protected Related (stairs, floors, Structural platforms, welds, Support for bolted Regulated connections, Events etc.)

Structural Monitoring III.A3.2-a 3.5.1-20 A Program Operator Access Structural Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Support for (Ext) Program Concrete, Non-Safety Protected Related (stairs, floors, Structural platforms, Support for concrete at Regulated locations of Events expansion &

grouted anchors, etc.)

III.A3.1-h 3.5.1-25 A 13 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Operator Access Structural Galvanized Plant Indoor Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 581, Component - Support for (Ext) Program 583, C Galvanized, Non-Safety Protected Related (stairs, Structural walkways, Support for removable Regulated platform, welds, Events bolted connections) 14 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Structural Monitoring III.A3.2-a 3.5.1-20 581, A Program 15 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 16 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME 1 Support Structural Carbon Steel Containment Air Loss of Material ASME Section XI IWB, III.B1.1.1-a 3.5.1-32 A

- Containment - Support for (Ext) IWC, IWD, IWF Inservice Carbon Steel, Safety Inspection Program Protected Related Boric Acid Corrosion III.B1.1.1-b 3.5.1-31 A Program ASME 1 Support Structural Concrete Containment Air Reduction in Conc Structural Monitoring III.B1.1.4-a 3.5.1-29 A

- Containment - Support for (Ext) Anchor Capacity Program Concrete, Safety Protected Related ASME 1 Support Expansion/ Bronze Containment Air Loss of Material None Required III.A4.2-b 3.5.1-20 515, I N/A N/A A, 515,

- Containment - Separation (Ext) 5004 Sliding Material, Structural Cont Cavity Support for Safety Related ASME 1 Support Expansion/ Bronze Containment Air Loss of Mechanical None Required III.B1.1.3-a 3.5.1-32 515, I N/A N/A A, 515,

- Containment - Separation (Ext) Function 5004 Sliding Material, Structural Protected Support for Safety Related 17 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 1 Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.1.1-a 3.5.1-32 A Tubing Support - Support for (Ext) IWC, IWD, IWF Inservice Auxiliary Bldg, Safety Inspection Program Carbon Steel, Related Protected Boric Acid Corrosion III.B1.1.1-b 3.5.1-31 583, A Program ASME 2 & 3 Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A Support - Support for (Ext) IWC, IWD, IWF Inservice Turbine (Water Regulated Inspection Program Treatment Area) Events

- Carbon Steel, Structural Protected Support for Safety Related ASME 2 & 3 Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A Support - Support for (Ext) Anchor Capacity Program Turbine (Water Regulated Treatment Area) Events

- Concrete, Structural Protected Support for Safety Related 18 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support -

Structural Auxiliary Bldg, Support for Carbon Steel, Safety Protected Related Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 583, A Program ASME Class 2 & Structural Cast Iron Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 582, F N/A N/A N/A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support -

Auxiliary Bldg, Cast Iron, Protected Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 582, F N/A N/A N/A Program 19 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A 3 Piping & Support for (Ext) Anchor Capacity Program Mechanical Regulated Component Events Support -

Structural Auxiliary Bldg, Support for

Concrete, Safety Protected Related ASME Class 2 & Structural Galvanized Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 581, A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support -

Structural Auxiliary Bldg, Support for Galvanized, Safety Protected Related Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 581, Program 583, A 20 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Expansion/ Bronze Plant Indoor Air Loss of Mechanical None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 3 Piping & Separation (Ext) Function 5004 Mechanical Structural Component Support for Support -

Safety Auxiliary Bldg, Related Sliding Material, Protected ASME Class 2 & Structural Carbon Steel Containment Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support -

Containment Bldg, Carbon Steel, Cont Cavity Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 A Program 21 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Carbon Steel Containment Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support -

Containment Bldg, Carbon Steel, Protected Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 A Program ASME Class 2 & Structural Concrete Containment Air Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A 3 Piping & Support for (Ext) Anchor Capacity Program Mechanical Safety Component Related Support -

Containment Bldg, Concrete, Protected 22 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Galvanized Containment Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 581, A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support -

Containment

Bldg, Galvanized, Cont Cavity Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 581, A Program ASME Class 2 & Structural Galvanized Containment Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support -

Containment

Bldg, Galvanized, Protected Boric Acid Corrosion III.B1.2.1-b 3.5.1-31 581, A Program 23 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Expansion/ Bronze Containment Air Loss of Mechanical None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 3 Piping & Separation (Ext) Function 5004 Mechanical Structural Component Support for Support -

Safety Containment Related Bldg, Sliding

Material, Protected ASME Class 2 & Structural Stainless Steel Treated Water Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 567, 3 Piping & Support for (Ext) 587, C Mechanical Safety Component Related Support -

Containment Bldg, Stainless, Borated ASME Class 2 & Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support - Intake Structure Bldg, Carbon Steel, Protected 24 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A 3 Piping & Support for (Ext) Anchor Capacity Program Mechanical Safety Component Related Support - Intake Structure Bldg,

Concrete, Protected ASME Class 2 & Structural Galvanized Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Safety Inspection Program Component Related Support - Intake Structure Bldg, Galvanized, Protected ASME Class 2 & Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support -

Structural Turbine Bldg, Support for Carbon Steel, Safety Protected Related 25 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A 3 Piping & Support for (Ext) Anchor Capacity Program Mechanical Regulated Component Events Support -

Structural Turbine Bldg, Support for

Concrete, Safety Protected Related ASME Class 2 & Structural Galvanized Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 581, A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support -

Structural Turbine Bldg, Support for Galvanized, Safety Protected Related ASME Class 2 & Expansion/ Bronze Plant Indoor Air Loss of Mechanical None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 3 Piping & Separation (Ext) Function 5004 Mechanical Structural Component Support for Support -

Safety Turbine Bldg, Related

Sliding, Protected 26 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Aluminum Atmosphere/ Loss of Material Boric Acid Corrosion 501, F III.B1.2-4 5-36 A, 501 3 Piping & Support for Weather (Ext) Program Mechanical Safety Component Related Support - Yard,

Aluminum, Exposed ASME Class 2 & Structural Carbon Steel Plant Indoor Air Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 518, A 3 Piping & Support for (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support - Yard, Structural Carbon Steel, Support for Below Grade Safety Related ASME Class 2 & Structural Carbon Steel Atmosphere/ Loss of Material ASME Section XI IWB, III.B1.2.1-a 3.5.1-32 A 3 Piping & Support for Weather (Ext) IWC, IWD, IWF Inservice Mechanical Regulated Inspection Program Component Events Support - Yard, Structural Carbon Steel, Support for Exposed Safety Related 27 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes ASME Class 2 & Structural Concrete Atmosphere/ Reduction in Conc Structural Monitoring III.B1.2.3-a 3.5.1-29 A 3 Piping & Support for Weather (Ext) Anchor Capacity Program Mechanical Regulated Component Events Support - Yard, Structural

Concrete, Support for Exposed Safety Related Elec Component Structural Carbon Steel Plant Indoor Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 583, A Support - Support for (Ext) Program Auxiliary Bldg, Non-Safety Carbon Steel, Related Protected Structural Support for Regulated Events Structural Support for Safety Related III.B3.1-b 3.5.1-31 583, A 28 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Structural Monitoring III.B2.1-a 3.5.1-29 A Program III.B3.1-a 3.5.1-29 A Elec Component Structural Carbon Steel Raw Water (Ext) Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 594, A Support - Support for Program Auxiliary Bldg, Non-Safety Carbon Steel, Related Raw Water Structural Support for Regulated Events Structural Support for Safety Related 29 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Support for (Ext) Anchor Capacity Program Auxiliary Bldg, Non-Safety Concrete, Related Protected Structural Support for Regulated Events Structural Support for Safety Related III.B3.2-a 3.5.1-29 A 30 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Raw Water (Ext) Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Support for Anchor Capacity Program Auxiliary Bldg, Non-Safety Concrete, Raw Related Water Structural Support for Regulated Events Structural Support for Safety Related Elec Component Structural Galvanized Plant Indoor Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, A Support - Support for (Ext) Program Auxiliary Bldg, Non-Safety Galvanized, Related Protected Structural Support for Regulated Events Structural Support for Safety Related 31 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B3.1-b 3.5.1-31 581, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program III.B3.1-a 3.5.1-29 581, A Elec Component Structural Galvanized Raw Water (Ext) Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, Support - Support for Program 594, A Auxiliary Bldg, Non-Safety Galvanized, Raw Related Water Structural Support for Regulated Events Structural Support for Safety Related 32 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 A Support - Support for (Ext) Program Containment Safety Bldg, Carbon Related

Steel, Containment Cavity III.B3.1-b 3.5.1-31 A Structural Monitoring III.B2.1-a 3.5.1-29 A Program III.B3.1-a 3.5.1-29 A Elec Component Structural Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 A Support - Support for (Ext) Program Containment Safety Bldg, Carbon Related Steel, Protected III.B3.1-b 3.5.1-31 A Structural Monitoring III.B2.1-a 3.5.1-29 A Program 33 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B3.1-a 3.5.1-29 A Elec Component Structural Concrete Containment Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Support for (Ext) Anchor Capacity Program Containment Safety Bldg, Concrete, Related Protected III.B3.2-a 3.5.1-29 A Elec Component Structural Galvanized Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, A Support - Support for (Ext) Program Containment Safety Bldg, Related Galvanized, Containment Cavity III.B3.1-b 3.5.1-31 581, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program III.B3.1-a 3.5.1-29 581, A 34 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Galvanized Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, A Support - Support for (Ext) Program Containment Safety Bldg, Related Galvanized, Protected III.B3.1-b 3.5.1-31 581, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program III.B3.1-a 3.5.1-29 581, A Elec Component Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Support - Support for (Ext) Program Discharge Non-Safety Structure, Related Carbon Steel, Protected III.B3.1-a 3.5.1-29 A 35 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Support - Support for (Ext) Program Discharge Non-Safety Structure, Related Galvanized, Protected III.B3.1-a 3.5.1-29 581, A Elec Component Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Support - Intake Support for (Ext) Program Structure Bldg, Non-Safety Carbon Steel, Related Protected Structural Support for Regulated Events Structural Support for Safety Related III.B3.1-a 3.5.1-29 A 36 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Intake Support for (Ext) Anchor Capacity Program Structure Bldg, Non-Safety Concrete, Related Protected Structural Support for Regulated Events Structural Support for Safety Related III.B3.2-a 3.5.1-29 A 37 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Support - Intake Support for (Ext) Program Structure Bldg, Non-Safety Galvanized, Related Protected Structural Support for Regulated Events Structural Support for Safety Related III.B3.1-a 3.5.1-29 581, A Elec Component Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Support - Switch Support for (Ext) Program Yard Relay Regulated House Group Events Bldg, Carbon Steel, Protected III.B3.1-a 3.5.1-29 A 38 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Switch Support for (Ext) Anchor Capacity Program Yard Relay Regulated House Group Events Bldg, Concrete, Protected III.B3.2-a 3.5.1-29 A Elec Component Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Support - Switch Support for (Ext) Program Yard Relay Regulated House Group Events

Bldg, Galvanized, Protected III.B3.1-a 3.5.1-29 581, A Elec Component Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Support - Support for (Ext) Program Turbine Bldg, Regulated Carbon Steel, Events Protected III.B3.1-a 3.5.1-29 A 39 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Support for (Ext) Anchor Capacity Program Turbine Bldg, Regulated Concrete, Events Protected III.B3.2-a 3.5.1-29 A Elec Component Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Support - Support for (Ext) Program Turbine Bldg, Regulated Galvanized, Events Protected III.B3.1-a 3.5.1-29 581, A Elec Component Structural Carbon Steel Atmosphere/ Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Support - Yard, Support for Weather (Ext) Program Carbon Steel, Regulated Exposed Events III.B3.1-a 3.5.1-29 A 40 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Elec Component Structural Concrete Atmosphere/ Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Support - Yard, Support for Weather (Ext) Anchor Capacity Program Concrete, Regulated Exposed Events III.B3.2-a 3.5.1-29 A Elec Component Structural Galvanized Atmosphere/ Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Support - Yard, Support for Weather (Ext) Program Galvanized, Regulated Exposed Events III.B3.1-a 3.5.1-29 581, A Elec Component Structural Galvanized Raw Water (Ext) Loss of Material Structural Monitoring III.B3.1-a 3.5.1-29 581, Support - Yard, Support for Program 594, A Galvanized, Raw Regulated Water Events High Strength Structural Carbon Steel Containment Air Cracking Bolting Integrity Program III.B1.1.2-a 3.5.1-33 A Bolting - Support for (Ext)

Containment Safety Building, Carbon Related Steel, Protected 41 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material ASME Section XI IWB, III.B1.1.1-a 3.5.1-32 A IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A Boric Acid Corrosion III.B1.1.1-b 3.5.1-31 A Program III.B1.2.1-b 3.5.1-31 A Non-ASME Structural Aluminum Plant Indoor Air Loss of Material Boric Acid Corrosion VII.A1.1-a 3.3.1-11 503, F III.B2-5 5-36 A, 503 Component Support for (Ext) Program Support - Safety Auxiliary Bldg, Related

Aluminum, Protected 42 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 583, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Auxiliary Bldg, Support for Carbon Steel, Regulated Protected Events Structural Support for Safety Related III.B4.1-b 3.5.1-31 583, A Structural Monitoring III.B2.1-a 3.5.1-29 A Program III.B4.1-a 3.5.1-29 A 43 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support -

Structural Auxiliary Bldg, Support for

Concrete, Regulated Protected Events Structural Support for Safety Related III.B4.3-a 3.5.1-29 A 44 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Galvanized Plant Indoor Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, Piping & Support for (Ext) Program 583, A Mechanical Non-Safety Component Related Support -

Structural Auxiliary Bldg, Support for Galvanized, Regulated Protected Events Structural Support for Safety Related III.B4.1-b 3.5.1-31 581, 583, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program III.B4.1-a 3.5.1-29 581, A 45 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Stainless Steel Treated Water Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 578, C Piping & Support for (Ext)

Mechanical Safety Component Related Support -

Auxiliary Bldg, Stainless, Borated Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support - Boiler Building, Carbon Steel, Protected III.B4.1-a 3.5.1-29 A Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support - Boiler

Building, Concrete, Protected 46 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B4.3-a 3.5.1-29 A Non-ASME Structural Aluminum Containment Air Loss of Material Boric Acid Corrosion 502, F III.B2-5 5-36 A, 502 Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Containment Bldg, Aluminum, Protected Non-ASME Structural Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Containment Support for Bldg, Carbon Safety

Steel, Related Containment Cavity III.B4.1-b 3.5.1-31 A Structural Monitoring III.B2.1-a 3.5.1-29 A Program 47 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B4.1-a 3.5.1-29 A Non-ASME Structural Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Containment Support for Bldg, Carbon Safety Steel, Protected Related III.B4.1-b 3.5.1-31 A Structural Monitoring III.B2.1-a 3.5.1-29 A Program III.B4.1-a 3.5.1-29 A 48 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Containment Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support -

Structural Containment Support for Bldg, Concrete, Safety Protected Related III.B4.3-a 3.5.1-29 A Non-ASME Structural Galvanized Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Containment Support for

Bldg, Safety Galvanized, Related Containment Cavity III.B4.1-b 3.5.1-31 581, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program 49 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.B4.1-a 3.5.1-29 581, A Non-ASME Structural Galvanized Containment Air Loss of Material Boric Acid Corrosion III.B2.1-b 3.5.1-31 581, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Containment Support for

Bldg, Safety Galvanized, Related Protected III.B4.1-b 3.5.1-31 581, A Structural Monitoring III.B2.1-a 3.5.1-29 581, A Program III.B4.1-a 3.5.1-29 581, A 50 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Stainless Steel Treated Water Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 567, Piping & Support for (Ext) 587, C Mechanical Non-Safety Component Related Support -

Structural Containment Support for Bldg, Stainless, Safety Borated Related Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Discharge Structure, Carbon Steel, Protected III.B4.1-a 3.5.1-29 A 51 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Cast Iron Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 582, F N/A N/A N/A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Discharge Structure, Cast Iron, Protected Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support -

Discharge Structure,

Concrete, Protected III.B4.3-a 3.5.1-29 A 52 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Discharge Structure, Galvanized, Protected III.B4.1-a 3.5.1-29 581, A Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Regulated Component Events Support -

Feedwater Purity Bldg, Carbon Steel, Protected III.B4.1-a 3.5.1-29 A 53 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Regulated Component Events Support -

Feedwater Purity Bldg, Concrete, Protected III.B4.3-a 3.5.1-29 A Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support - Intake Structural Structure Bldg, Support for Carbon Steel, Regulated Protected Events Structural Support for Safety Related III.B4.1-a 3.5.1-29 A 54 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support - Intake Structural Structure Bldg, Support for

Concrete, Regulated Protected Events Structural Support for Safety Related III.B4.3-a 3.5.1-29 A Non-ASME Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support - Intake Structural Structure Bldg, Support for Galvanized, Safety Protected Related III.B4.1-a 3.5.1-29 581, A 55 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Turbine Bldg, Support for Carbon Steel, Regulated Protected Events Structural Support for Safety Related III.B4.1-a 3.5.1-29 A 56 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support -

Structural Turbine Bldg, Support for

Concrete, Regulated Protected Events Structural Support for Safety Related III.B4.3-a 3.5.1-29 A 57 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support -

Structural Turbine Bldg, Support for Galvanized, Regulated Protected Events Structural Support for Safety Related III.B4.1-a 3.5.1-29 581, A Non-ASME Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for (Ext) Program Mechanical Non-Safety Component Related Support - Water Structural Treatment Bldg, Support for Carbon Steel, Regulated Protected Events III.B4.1-a 3.5.1-29 A 58 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Plant Indoor Air Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support - Water Structural Treatment Bldg, Support for

Concrete, Regulated Protected Events III.B4.3-a 3.5.1-29 A Non-ASME Structural Carbon Steel Atmosphere/ Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 A Piping & Support for Weather (Ext) Program Mechanical Regulated Component Events Support - Yard, Structural Carbon Steel, Support for Exposed Safety Related III.B4.1-a 3.5.1-29 A 59 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Concrete Atmosphere/ Reduction in Conc Structural Monitoring III.B2.2-a 3.5.1-29 A Piping & Support for Weather (Ext) Anchor Capacity Program Mechanical Non-Safety Component Related Support - Yard, Structural

Concrete, Support for Exposed Regulated Events Structural Support for Safety Related III.B4.3-a 3.5.1-29 A 60 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Non-ASME Structural Galvanized Atmosphere/ Loss of Material Structural Monitoring III.B2.1-a 3.5.1-29 581, A Piping & Support for Weather (Ext) Program Mechanical Non-Safety Component Related Support - Yard, Structural Galvanized, Support for Exposed Regulated Events Structural Support for Safety Related III.B4.1-a 3.5.1-29 581, A Spent Fuel Radiation Boron Carbide Treated Water Loss of Material None Required VII.A2.1-b 3.3.1-10 595, F N/A N/A N/A Storage Rack - Shielding (Ext)

Auxiliary Building, Boron Carbide, Borated Water 61 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Spent Fuel Structural Stainless Steel Treated Water Loss of Material Water Chemistry Program VII.A2.1-c 3.3.1-13 H III.A5-13 5-25 C Storage Rack - Support for (Ext)

Auxiliary Safety Building, Related Stainless Steel, Borated Water 62 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 63 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Containment Heat Sink Carbon Steel Containment Air Loss of Leak Containment Leakage II.A3.2-b 3.5.1-05 538, A Shell & Base (Ext) Tightness Testing Program Pressure Slab -

Boundary/

Containment Fission Bldg, Carbon Product Steel, Protected Retention (air locks, Structural equipment Support for hatch, liner Safety

plate, Related penetrations)

Structural Support for Regulated Events Loss of Material Boric Acid Corrosion II.A1.2-a 3.5.1-12 577, A Program Containment Inservice II.A1.2-a 3.5.1-12 A Inspection Program II.A3.1-a 3.5.1-03 A II.A3.2-a 3.5.1-04 A 64 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Containment Leakage II.A1.2-a 3.5.1-12 A Testing Program II.A3.1-a 3.5.1-03 A II.A3.2-a 3.5.1-04 A Containment Pressure Concrete Soil (Ext) Change in Material None Required II.A1.1-b 3.5.1-07 572, A Shell & Base Boundary/ Properties Slab - Fission Containment Product Bldg, Concrete, Retention Below Grade Radiation (base mat, Shielding foundation, wall, Structural embedded steel, Support for etc.)

Safety Related Shelter/

Protection II.A1.1-c 3.5.1-07 573, A Cracking None Required II.A1.1-f 3.5.1-08 547, A 65 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and None Required II.A1.1-d 3.5.1-16 574, A Expansion Cracking, Loss of None Required II.A1.1-e 3.5.1-07 573, A Bond/Matl Loss of Material None Required II.A1.1-a 3.5.1-16 575, A None Required II.A1.1-c 3.5.1-07 573, A 66 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Containment Heat Sink Concrete Atmosphere/ Change in Material Containment Inservice II.A1.1-b 3.5.1-07 A Shell & Base Weather (Ext) Properties Inspection Program Missile Barrier Slab -

Containment Pressure Bldg, Concrete, Boundary/

Exposed Fission Product (dome, wall, Retention base mat, embedded steel, Radiation etc.) Shielding Shelter /

Protection Structural Support for Regulated Events Structural Support for Safety Related II.A1.1-c 3.5.1-07 A Cracking Containment Inservice II.A1.1-a 3.5.1-16 A Inspection Program 67 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Structural Monitoring II.A1.1-f 3.5.1-08 547, A Program Cracking and Containment Inservice II.A1.1-d 3.5.1-16 A Expansion Inspection Program Cracking, Loss of Containment Inservice II.A1.1-e 3.5.1-07 A Bond/Matl Inspection Program Loss of Material Containment Inservice II.A1.1-a 3.5.1-16 A Inspection Program II.A1.1-c 3.5.1-07 A Containment Pressure Elastomers Containment Air Change in Material Containment Inservice II.A3.3-a 3.5.1-06 A Shell & Base Boundary/ (Ext) Properties Inspection Program Slab - Fission Containment Product Bldg, Elastomer, Retention Protected Shelter/

(seals, gaskets, Protection moisture barriers) 68 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Containment Leakage II.A3.3-a 3.5.1-06 A Testing Program Cracking Containment Inservice II.A3.3-a 3.5.1-06 A Inspection Program Containment Leakage II.A3.3-a 3.5.1-06 A Testing Program Containment Heat Sink Stainless Steel Containment Air Loss of Material Containment Inservice II.A3.1-a 3.5.1-03 570, A Shell & Base (Ext) Inspection Program Pressure Slab -

Boundary/

Containment Fission Bldg, Stainless Product Steel, Protected Retention (fuel transfer tube and closure flange)

Containment Leakage II.A3.1-a 3.5.1-03 570, A Testing Program 69 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Containment Pressure Carbon Steel Atmosphere/ Loss of Material Containment Inservice II.A1.3-a 3.5.1-15 A Shell Boundary/ Weather (Ext) Inspection Program Prestressing Fission System - Product Containment Retention Bldg, Carbon Structural Steel, Exposed Support for (includes Safety tendons and Related anchorage components) 70 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 71 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Heat Sink Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.A4.2-a 3.5.1-20 580, III.B5-7 5-36 A, 580,

- Carbon Steel, (Ext) Program 585, H 585 HELB Protected Shielding (column, beam, Pipe Whip truss, platform, Restraint floor grating or plate, catwalk, Structural bracing, Support for threaded Regulated fastener, Events concrete expansion bolt, Structural column base Support for Safety plate, welds, Related etc.)

Support for Non-Safety Related III.B5.1-b 3.5.1-29 A Structural Monitoring III.A4.2-a 3.5.1-20 580, A Program 72 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Heat Sink Concrete Containment Air Cracking and Structural Monitoring III.A4.1-b 3.5.1-20 A

- Concrete, (Ext) Expansion Program HELB Containment Shielding Cavity Missile Barrier (reactor shield walls including Radiation reinforcements, Shielding inserts, grouted Structural anchors)

Support for Safety Related Cracking, Loss of Structural Monitoring III.A4.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A4.1-a 3.5.1-20 A Program Change in Material None Required III.A4.1-c 3.5.1-27 576, A Properties 73 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Direct Flow Concrete Containment Air Cracking Structural Monitoring 559, H

- Concrete, (Ext) Program Heat Sink Protected HELB (concrete &

Shielding masonry wall, column, Pipe Whip pedestal, beam, Restraint slab, grout, Radiation reinforcements, Shielding concrete around expansion & Structural grouted anchors, Support for etc.) Regulated Events Structural Support for Non-Safety Related Structural Support for Safety Related Cracking and Structural Monitoring III.A4.1-b 3.5.1-20 A Expansion Program 74 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Structural Monitoring III.A4.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A4.1-a 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Fuel Related Structural Stainless Steel Containment Air Cracking None Required III.A5.2-b 3.5.1-23 535, E Component - Support for (Ext)

Stainless, Safety Protected Related (refueling cavity

liner, containment liner and sump screen, transfer tube)

Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 578, 587, A Structural Monitoring III.A5.2-b 3.5.1-23 596, E Program 75 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Fuel Related Structural Carbon Steel Containment Air Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 578, III.B2-9 5-33 E, 578, Component - Support for (Ext) 579, F 579 Carbon Steel, Safety Protected Related (anchor bolts for refueling cavity liner and transfer tube appurtenances)

HELB/MELB HELB Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 C Component - Shielding (Ext) Program Carbon Steel, Pipe Whip Protected Restraint (steel curbs, Structural pipe whip Support for restraints, spray Safety shields, etc.)

Related Structural Monitoring III.A4.2-a 3.5.1-20 580, C Program 76 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HELB/MELB Direct Flow Concrete Containment Air Cracking Structural Monitoring H III.A3-11 5-26 A Component - (Ext) Program Flood

Concrete, Protection Protected Heat Sink (curbs, sump, pipe whip HELB restraint grout, Shielding concrete at Pipe Whip locations of Restraint expansion &

grouted anchors, etc.)

Cracking and Structural Monitoring III.A4.1-b 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A4.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A4.1-a 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program 77 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HVAC Structural Carbon Steel Containment Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 C Component - Support for (Ext) Program Carbon Steel, Safety Protected Related (damper &

louver mounting frames)

Structural Monitoring III.A4.2-a 3.5.1-20 580, C Program HVAC Structural Galvanized Containment Air Loss of Material Boric Acid Corrosion III.B5.1-b 3.5.1-31 C Component - Support for (Ext) Program Galvanized, Safety Protected Related (damper &

louver mounting frames)

Structural Monitoring III.A4.2-a 3.5.1-20 580, C Program 78 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Missile Shield - Heat Sink Concrete Containment Air Cracking and Structural Monitoring III.A4.1-b 3.5.1-20 A Concrete, (Ext) Expansion Program Missile Barrier Containment Cavity (removable missile shield above reactor vessel)

Cracking, Loss of Structural Monitoring III.A4.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A4.1-a 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program 79 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 80 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Cast Iron Raw Water (Ext) Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 580,

- Cast Iron, Raw Support for Program 582, A Water Non-Safety Related (sluice gates)

Building Framing Structural Carbon Steel Raw Water (Ext) Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 580, A

- Support for Program Discharge/Intake Non-Safety Crib - Carbon Related Steel, Raw Water (sluice gate, column, bracket, beam, bracing, threaded

fastener, connector, weld, etc.)

81 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A6.1-a 3.5.1-22 571, A

- Concrete, Below Support for Grade Non-Safety Related (wall, footing, foundation, slab,

grout, reinforcement, trenches, cable pits, tunnels, etc.)

III.A6.1-e 3.5.1-22 544, A Change in Material None Required III.A6.1-b 3.5.1-22 557, A Properties III.A6.1-e 3.5.1-22 544, A Cracking and None Required III.A6.1-c 3.5.1-22 543, A Expansion Cracking, Loss of None Required III.A6.1-d 3.5.1-22 544, A Bond/Matl Cracking None Required III.A6.1-f 3.5.1-22 547, A 82 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Atmosphere/ Change in Material Structural Monitoring III.A6.1-b 3.5.1-22 A

- Concrete, Support for Weather (Ext) Properties Program Exposed Non-Safety Related (foundations, masonry &

concrete wall, floor/ roof slab,

grout, reinforcements, steel shapes, concrete around expansion &

grouted anchors)

III.A6.1-e 3.5.1-22 A Cracking Structural Monitoring III.A6.3-a 3.5.1-24 A Program III.A6.1-a 3.5.1-22 A III.A6.1-f 3.5.1-22 A Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program 83 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Structural Monitoring III.A6.1-d 3.5.1-22 A Bond/Material Program Loss of Material Structural Monitoring III.A6.1-a 3.5.1-22 A Program III.A6.1-e 3.5.1-22 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Building Framing Structural Concrete Raw Water (Ext) Change in Material Structural Monitoring III.A6.1-b 3.5.1-22 557, A

- Concrete, Raw Support for Properties Program Water Non-Safety Related (wall, footing, foundation, slab,

grout, reinforcements)

III.A6.1-e 3.5.1-22 A Cracking Structural Monitoring III.A6.1-a 3.5.1-22 A Program 84 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A6.1-f 3.5.1-22 A Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program Loss of Material Structural Monitoring III.A6.1-a 3.5.1-22 A Program III.A6.1-e 3.5.1-22 A III.A6.1-h 3.5.1-22 A 85 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 86 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, A

- Carbon Steel, Support for (Ext) Program Protected Regulated Events (column, beam,

bracing, threaded
fastener, concrete expansion bolt, column base plate, welds, etc.)

Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Concrete, Support for Below Grade Regulated Events (pedestal, grade beam, footing, foundation, slab,

grout, reinforcement, trenches, cable pits, etc.)

III.A3.1-g 3.5.1-21 544, A 87 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing Structural Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A

- Concrete, Support for Weather (Ext) Properties Program Exposed Regulated Events (foundations, masonry/

concrete wall,

grout, reinforcement, concrete around expansion &

grouted anchors, etc.)

88 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A3.1-f 3.5.1-20 A Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Program III.A3.1-a 3.5.1-20 A III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 89 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A

- Concrete, Support for (Ext) Program Protected Regulated Events (foundations, masonry/

concrete wall,

column, pedestal, beam, slab, grout, reinforcement, concrete around expansion &

grouted anchors, etc.)

III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Material Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program 90 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 91 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 92 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Carbon Steel Raw Water (Ext) Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 580, A

- Carbon Steel, Support for Program Raw Water Regulated Events (gates, guides, and trash racks) Structural Support for Safety Related Building Framing Structural Cast Iron Raw Water (Ext) Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 580,

- Cast Iron, Raw Support for Program 582, A Water Regulated Events (Sluice Gates)

Structural Support for Safety Related Building Framing Structural Galvanized Raw Water (Ext) Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 581, A

- Galvanized, Support for Program Raw Water Regulated Events (fasteners and anchor bolts) Structural Support for Safety Related 93 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Shelter / Concrete Soil (Ext) Loss of Material None Required III.A6.1-a 3.5.1-22 571, A

- Concrete, Protection Below Grade Structural (wall, foundation, Support for slab, grout, Regulated reinforcement, Events trenches, cable Structural pits, tunnels, Support for etc.)

Safety Related III.A6.1-e 3.5.1-22 544, A Change in Material None Required III.A6.1-b 3.5.1-22 557, A Properties III.A6.1-e 3.5.1-22 544, A Cracking and None Required III.A6.1-c 3.5.1-22 543, A Expansion Cracking, Loss of None Required III.A6.1-d 3.5.1-22 544, A Bond/Matl 94 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking None Required III.A6.1-f 3.5.1-22 547, A Building Framing Fire Barrier Concrete Atmosphere/ Change in Material Structural Monitoring III.A6.1-b 3.5.1-22 A

- Concrete, Weather (Ext) Properties Program Flood Exposed Protection (wall, beam, Missile Barrier floor slab, roof slab, grout, Shelter/

reinforcements, Protection grouted anchors, Structural etc.)

Support for Regulated Events Structural Support for Safety Related III.A6.1-e 3.5.1-22 A Cracking Structural Monitoring III.A6.3-a 3.5.1-24 A Program III.A6.1-a 3.5.1-22 A 95 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A6.1-f 3.5.1-22 A Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program Cracking, Loss of Structural Monitoring III.A6.1-d 3.5.1-22 A Bond/Material Program Loss of Material Structural Monitoring III.A6.1-a 3.5.1-22 A Program III.A6.1-e 3.5.1-22 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A concrete Anchor Program Capacity 96 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Direct Flow Concrete Plant Indoor Air Cracking Structural Monitoring III.A6.3-a 3.5.1-24 A

- Concrete, (Ext) Program Flood Protected Protection (wall, beam, Shelter/

floor slab, grout, Protection reinforcements, grouted anchors, Structural etc.) Support for Regulated Events Structural Support for Safety Related III.A6.1-f 3.5.1-22 A Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program Cracking, Loss of Structural Monitoring III.A6.1-d 3.5.1-22 A Bond/Material Program Loss of Material Structural Monitoring III.A6.1-a 3.5.1-22 A Program 97 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A6.1-e 3.5.1-22 A Loss of Strength Structural Monitoring III.A6.1-b 3.5.1-22 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Building Framing Structural Concrete Raw Water (Ext) Change in Material Structural Monitoring III.A6.1-b 3.5.1-22 A

- Concrete, Raw Support for Properties Program Water Regulated Events (wall, column, beam, footing, Structural foundation slab, Support for floor slab, grout, Safety reinforcements, Related etc.)

III.A6.1-e 3.5.1-22 A Cracking Structural Monitoring III.A6.1-a 3.5.1-22 A Program III.A6.1-f 3.5.1-22 A 98 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program Loss of Material Structural Monitoring III.A6.1-a 3.5.1-22 A Program III.A6.1-e 3.5.1-22 A III.A6.1-h 3.5.1-22 A Flood Barrier - Flood Concrete Plant Indoor Air Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Concrete, Protection (Ext) Expansion Program Protected (concrete interior wall in southeast corner)

Cracking, Loss of Structural Monitoring III.A6.1-d 3.5.1-22 A Bond/Material Program Loss of Material Structural Monitoring III.A6.1-e 3.5.1-22 A Program Loss of Strength Structural Monitoring III.A6.1-b 3.5.1-22 A Program 99 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HELB/MELB Direct Flow Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 580, C Component - (Ext) Program Flood Carbon Steel, Protection Protected Structural (steel curbs, Support for floor drains, Safety shields, etc.)

Related HELB/MELB Direct Flow Concrete Plant Indoor Air Cracking Structural Monitoring III.A6.3-a 3.5.1-24 A Component - (Ext) Program Flood

Concrete, Protection Protected (concrete /

masonry wall, curbs, etc.)

Cracking and Structural Monitoring III.A6.1-c 3.5.1-22 A Expansion Program (XI.S6)

Cracking, Loss of Structural Monitoring III.A6.1-d 3.5.1-22 A Bond/Material Program (XI.S6)

Loss of Material Structural Monitoring III.A6.1-e 3.5.1-22 A Program (XI.S6) 100 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program (XI.S6) 101 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 102 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Built-Up Roofing Shelter/ Built-up Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5000

- Auxiliary Bldg - Protection Roofing Weather (Ext) Properties Program Tarred, Exposed Loss of Form Structural Monitoring J N/A N/A A, 5000 Program Loss of Material Structural Monitoring J N/A N/A A, 5000 Program Built-Up Roofing Structural Built-up Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5000

- Discharge Support for Roofing Weather (Ext) Properties Program Structure - Non-Safety Tarred, Exposed Related Loss of Form Structural Monitoring J N/A N/A A, 5000 Program Loss of Material Structural Monitoring J N/A N/A A, 5000 Program Built-Up Roofing Shelter/ Built-up Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5000

- Intake Protection Roofing Weather (Ext) Properties Program Structure Bldg -

Tarred, Exposed 103 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Form Structural Monitoring J N/A N/A A, 5000 Program Loss of Material Structural Monitoring J N/A N/A A, 5000 Program Built-Up Roofing Structural Built-up Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5000

- Switch Yard Support for Roofing Weather (Ext) Properties Program Relay House Regulated Bldg - Tarred, Events Exposed Loss of Form Structural Monitoring J N/A N/A A, 5000 Program Loss of Material Structural Monitoring J N/A N/A A, 5000 Program Built-Up Roofing Structural Built-up Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5000

- Water Support for Roofing Weather (Ext) Properties Program Treatment Bldg - Non-Safety Tarred, Exposed Related Loss of Form Structural Monitoring J N/A N/A A, 5000 Program 104 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Structural Monitoring J N/A N/A A, 5000 Program Crane - Auxiliary Structural Carbon Steel Plant Indoor Air Loss of Material Overhead Load Handling VII.B.1-b 3.3.1-16 B Bldg - Carbon Support for (Ext) Systems Inspection Steel, Protected Safety Program Related VII.B.2-a 3.3.1-16 B Crane - Structural Carbon Steel Containment Air Loss of Material Overhead Load Handling VII.B.1-b 3.3.1-16 B Containment Support for (Ext) Systems Inspection Bldg - Carbon Safety Program Steel, Protected Related VII.B.2-a 3.3.1-16 B Crane Lift Structural Carbon Steel Containment Air Loss of Material Overhead Load Handling VII.B.1-b 3.3.1-16 D Device - Support for (Ext) Systems Inspection Containment Non-Safety Program Bldg - Carbon Related Steel, Protected 105 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Crane Support - Structural Carbon Steel Plant Indoor Air Loss of Material Overhead Load Handling VII.B.1-b 3.3.1-16 B Auxiliary Bldg - Support for (Ext) Systems Inspection Carbon Steel, Non-Safety Program Protected Related Structural Support for Safety Related Crane Support - Structural Carbon Steel Containment Air Loss of Material Overhead Load Handling VII.B.1-b 3.3.1-16 B Containment Support for (Ext) Systems Inspection Bldg - Carbon Non-Safety Program Steel, Protected Related Structural Support for Safety Related Fire Barrier - Fire Barrier Carbon Steel Plant Indoor Air Loss of Material Fire Protection Program VII.G.3-d 3.3.1-20 591, B Auxiliary Bldg - (Ext)

Carbon Steel, Protected 106 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Fire Barrier - Fire Barrier Concrete Atmosphere/ Change in Material Fire Protection Program VII.G.3-b 3.3.1-30 B Auxiliary Bldg - Weather (Ext) Properties

Concrete, Exposed Structural Monitoring VII.G.3-b 3.3.1-30 A Program Cracking Fire Protection Program VII.G.3-b 3.3.1-30 B Structural Monitoring VII.G.3-b 3.3.1-30 A Program Cracking and Fire Protection Program VII.G.3-b 3.3.1-30 B Expansion Structural Monitoring VII.G.3-b 3.3.1-30 A Program Cracking, Loss of Fire Protection Program VII.G.3-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.3-c 3.3.1-30 A Program 107 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Fire Protection Program VII.G.3-b 3.3.1-30 B Structural Monitoring VII.G.3-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Concrete Plant Indoor Air Cracking Fire Protection Program VII.G.3-b 3.3.1-30 B Auxiliary Bldg - (Ext)

Concrete, Protected Structural Monitoring VII.G.3-b 3.3.1-30 A Program Cracking and Fire Protection Program VII.G.3-b 3.3.1-30 B Expansion Structural Monitoring VII.G.3-b 3.3.1-30 A Program Cracking, Loss of Fire Protection Program VII.G.3-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.3-c 3.3.1-30 A Program 108 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Fire Protection Program VII.G.3-b 3.3.1-30 H III.A3-9 5-21 E Structural Monitoring VII.G.3-b 3.3.1-30 H III.A3-9 5-21 E Program Fire Barrier - Fire Barrier Fire Stops Plant Indoor Air Cracking / Fire Protection Program VII.G.3-a 3.3.1-20 592, B Auxiliary Bldg - [Sealant / (Ext) Delamination Fire Stop, Maranite]

Protected VII.G.4-a 3.3.1-20 592, B Loss of Material Fire Protection Program VII.G.3-a 3.3.1-20 H VII.G-1 3-46 B, 5001 VII.G.4-a 3.3.1-20 H VII.G-1 3-46 B, 5001 Separation Fire Protection Program VII.G.3-a 3.3.1-20 592, B VII.G.4-a 3.3.1-20 592, B Fire Barrier - Fire Barrier Fire Wraps Plant Indoor Air Cracking Fire Protection Program J N/A N/A B, 5002 Auxiliary Bldg - [Mineral-Wool (Ext)

Fire Wrap, Batts]

Protected 109 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Fire Protection Program J N/A N/A B, 5002 Fire Barrier - Fire Barrier Carbon Steel Plant Indoor Air Loss of Material Fire Protection Program VII.G.5-c 3.3.1-20 B Containment (Ext)

Bldg - Carbon Steel, Protected Fire Barrier - Fire Barrier Concrete Atmosphere/ Change in Material Containment Inservice II.A1.1-b 3.5.1-07 A Containment Weather (Ext) Properties Inspection Program Bldg - Concrete, Exposed II.A1.1-c 3.5.1-07 A Cracking Containment Inservice II.A1.1-a 3.5.1-16 A Inspection Program Structural Monitoring II.A1.1-f 3.5.1-08 A Program Cracking and Containment Inservice II.A1.1-d 3.5.1-16 A Expansion Inspection Program Cracking, Loss of Containment Inservice II.A1.1-e 3.5.1-07 A Bond/Material Inspection Program 110 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Containment Inservice II.A1.1-a 3.5.1-16 A Inspection Program II.A1.1-c 3.5.1-07 A Fire Barrier - Fire Barrier Carbon Steel Plant Indoor Air Loss of Material Fire Protection Program VII.G.1-d 3.3.1-20 591, B Intake Structure (Ext)

Bldg - Carbon Steel, Protected Fire Barrier - Fire Barrier Concrete Atmosphere/ Change in Material Fire Protection Program VII.G.1-b 3.3.1-30 B Intake Structure Weather (Ext) Properties Bldg - Concrete, Exposed Structural Monitoring VII.G.1-b 3.3.1-30 A Program Cracking Fire Protection Program VII.G.1-b 3.3.1-30 B Structural Monitoring VII.G.1-b 3.3.1-30 A Program Cracking and Fire Protection Program VII.G.1-b 3.3.1-30 B Expansion 111 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Structural Monitoring VII.G.1-b 3.3.1-30 A Program Cracking, Loss of Fire Protection Program VII.G.1-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.1-c 3.3.1-30 A Program Loss of Material Fire Protection Program VII.G.1-b 3.3.1-30 B Structural Monitoring VII.G.1-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Fire Stops Plant Indoor Air Cracking / Fire Protection Program VII.G.1-a 3.3.1-20 592, B Intake Structure [Sealant / (Ext) Delamination Bldg - Fire Stop, Maranite]

Protected Loss of Material Fire Protection Program VII.G.1-a 3.3.1-20 H VII.G-1 3-46 B, 5001 Separation Fire Protection Program VII.G.1-a 3.3.1-20 592, B 112 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Fire Barrier - Fire Barrier Fire Wraps Plant Indoor Air Cracking Fire Protection Program J N/A N/A B, 5002 Intake Structure [Mineral-Wool (Ext)

Bldg - Fire Wrap, Batts]

Protected Loss of Material Fire Protection Program J N/A N/A B, 5002 Fire Barrier - Fire Barrier Carbon Steel Plant Indoor Air Loss of Material Fire Protection Program VII.G.2-d 3.3.1-20 B Turbine Bldg - (Ext)

Carbon Steel, Protected Fire Barrier - Fire Barrier Concrete Atmosphere/ Change in Material Fire Protection Program VII.G.2-b 3.3.1-30 B Turbine Bldg - Weather (Ext) Properties

Concrete, Exposed Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program 113 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Fire Protection Program VII.G.2-b 3.3.1-30 B Expansion Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking, Loss of Fire Protection Program VII.G.2-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.2-c 3.3.1-30 A Program Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Concrete Plant Indoor Air Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B Turbine Bldg - (Ext)

Concrete, Protected Structural Monitoring VII.G.2-b 3.3.1-30 A Program 114 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Fire Protection Program VII.G.2-b 3.3.1-30 B Expansion Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking, Loss of Fire Protection Program VII.G.2-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.2-c 3.3.1-30 A Program Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Fire Stops Plant Indoor Air Cracking / Fire Protection Program VII.G.2-a 3.3.1-20 592, B Turbine Bldg - [Sealant / (Ext) Delamination Fire Stop, Maranite]

Protected Loss of Material Fire Protection Program VII.G.2-a 3.3.1-20 H VII.G-1 3-46 B, 5001 Separation Fire Protection Program VII.G.2-a 3.3.1-20 592, B 115 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Fire Barrier - Fire Barrier Fire Wraps Plant Indoor Air Cracking Fire Protection Program J N/A N/A B, 5002 Turbine Bldg - [Mineral-Wool (Ext)

Fire Wrap, Batts]

Protected Loss of Material Fire Protection Program J N/A N/A B, 5002 Fire Barrier - Fire Barrier Concrete Atmosphere/ Change in Material Fire Protection Program VII.G.2-b 3.3.1-30 B Water Treatment Weather (Ext) Properties Bldg - Concrete, Exposed Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking and Fire Protection Program VII.G.2-b 3.3.1-30 B Expansion Structural Monitoring VII.G.2-b 3.3.1-30 A Program 116 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Fire Protection Program VII.G.2-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.2-c 3.3.1-30 A Program Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Concrete Plant Indoor Air Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B Water Treatment (Ext)

Bldg - Concrete, Protected Structural Monitoring VII.G.2-b 3.3.1-30 A Program Cracking and Fire Protection Program VII.G.2-b 3.3.1-30 B Expansion Structural Monitoring VII.G.2-b 3.3.1-30 A Program 117 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Fire Protection Program VII.G.2-c 3.3.1-30 B Bond/Material Structural Monitoring VII.G.2-c 3.3.1-30 A Program Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B Structural Monitoring VII.G.2-b 3.3.1-30 A Program Fire Barrier - Fire Barrier Fire Stops Plant Indoor Air Cracking / Fire Protection Program VII.G.2-a 3.3.1-20 592, B Water Treatment [Sealant / (Ext) Delamination Bldg - Fire Stop, Maranite]

Protected Loss of Material Fire Protection Program VII.G.2-a 3.3.1-20 H VII.G-1 3-46 B, 5001 Separation Fire Protection Program VII.G.2-a 3.3.1-20 592, B Fire Barrier - Fire Barrier Fire Wraps Plant Indoor Air Cracking Fire Protection Program J N/A N/A B, 5002 Water Treatment [Mineral-Wool (Ext)

Bldg - Fire Wrap, Batts]

Protected 118 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Fire Protection Program J N/A N/A B, 5002 Flood Barrier - Flood Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 Auxiliary Bldg - Protection (Ext) Properties Program Elastomer, Protected Cracking Structural Monitoring J N/A N/A A, 5003 Program Flood Barrier - Flood Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 Turbine Building Protection (Ext) Properties Program

- Elastomer, Protected Cracking Structural Monitoring J N/A N/A A, 5003 Program HELB/MELB & Direct Flow Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 EQ Civil/ (Ext) Properties Program Flood Structural Protection Component -

Auxiliary Bldg -

Elastomer, Protected 119 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking Structural Monitoring J N/A N/A A, 5003 Program HELB/MELB & Direct Flow Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 EQ Civil/ (Ext) Properties Program Flood Structural Protection Component -

Intake Structure Bldg -

Elastomer, Protected Cracking Structural Monitoring J N/A N/A A, 5003 Program Mech General Structural Elastomers Containment Air Change in Material Structural Monitoring J N/A N/A A, 5003 Component Support for (Ext) Properties Program Support - Safety Containment Related Bldg -

Elastomer, Protected Cracking Structural Monitoring J N/A N/A A, 5003 Program 120 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Riprap - Yard - Structural Soil Raw Water (Ext) Loss of Structural Monitoring III.A6.4-a 3.5.1-22 A Soil, Submerged Support for Material/Form Program Non-Safety Related Roof Flashing - Shelter/ Galvanized Atmosphere/ Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 A Auxiliary Bldg - Protection Weather (Ext) Program Galvanized, Exposed Roof Flashing - Shelter/ Galvanized Atmosphere/ Loss of Material Structural Monitoring III.A6.2-a 3.5.1-22 A Intake Structure Protection Weather (Ext) Program Bldg -

Galvanized, Exposed Roof Flashing - Structural Galvanized Atmosphere/ Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 A Switchyard Support for Weather (Ext) Program Relay House - Regulated Galvanized, Events Exposed Seal, Gasket or Shelter/ Elastomers Atmosphere/ Cracking Structural Monitoring J N/A N/A A, 5003 Filler - Auxiliary Protection Weather (Ext) Program Bldg -

Elastomer, Exposed 121 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Seal, Gasket or Direct Flow Elastomers Plant Indoor Air Change in Material Structural Monitoring III.B4.2-a 3.5.1-29 593, A Filler - Auxiliary (Ext) Properties Program Expansion /

Bldg -

Separation Elastomer, Protected Flood Protection Shelter/

Protection Cracking Structural Monitoring III.B4.2-a 3.5.1-29 593, A Program Seal, Gasket or Expansion / Elastomers Containment Air Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Separation (Ext) Properties Program Containment Flood Bldg -

Protection Elastomer, Protected Shelter/

Protection Cracking Structural Monitoring J N/A N/A A, 5003 Program 122 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Seal, Gasket or Structural Elastomers Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Discharge Support for Weather (Ext) Properties Program Structure - Non-Safety Elastomer, Related Exposed Cracking Structural Monitoring J N/A N/A A, 5003 Program Seal, Gasket or Structural Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Discharge Support for (Ext) Properties Program Structure - Non-Safety Elastomer, Related Protected Cracking Structural Monitoring J N/A N/A A, 5003 Program Seal, Gasket or Shelter/ Elastomers Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Intake Protection Weather (Ext) Properties Program Structure Bldg -

Elastomer, Exposed Cracking Structural Monitoring J N/A N/A A, 5003 Program 123 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Seal, Gasket or Shelter / Elastomers Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Protection Weather (Ext) Properties Program Switchyard Structural Relay House/

Support for Switchgear/

Regulated Safeguard Bldg -

Events Elastomer, Exposed Cracking Structural Monitoring J N/A N/A A, 5003 Program Seal, Gasket or Structural Elastomers Atmosphere/ Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Turbine Support for Weather (Ext) Properties Program Bldg - Non-Safety Elastomer, Related Exposed Cracking Structural Monitoring J N/A N/A A, 5003 Program Seal, Gasket or Flood Elastomers Plant Indoor Air Change in Material Structural Monitoring J N/A N/A A, 5003 Filler - Turbine Protection (Ext) Properties Program Bldg -

Shelter/

Elastomer, Protection Protected 124 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking Structural Monitoring J N/A N/A A, 5003 Program 125 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 126 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, A

- Safeguard Support for (Ext) Program Bus/Switchgear - Regulated Carbon Steel, Events Protected (floor beam, panels, welds, threaded fasteners, concrete expansion bolt, etc.)

Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Switchyard - Support for Concrete, Below Regulated Grade Events (grade beam,

footing, foundation, slab,
grout, reinforcement, trenches, cable pits, tunnels, etc.)

127 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A3.1-g 3.5.1-21 544, A Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl Cracking None Required III.A3.1-h 3.5.1-25 547, A 128 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A

- Switchyard - Support for Weather (Ext) Properties Program Concrete, Regulated Exposed Events (masonry/

concrete wall,

grout, reinforcements, foundations, concrete around expansion &

grouted anchors, bus supports, etc.)

III.A3.1-f 3.5.1-20 544, A Cracking Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.3-a 3.5.1-24 A III.A3.1-h 3.5.1-25 A 129 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Building Framing Structural Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.1-h 3.5.1-25 A

- Switchyard - Support for (Ext) Program Concrete, Regulated Protected Events (masonry roof bearing walls, reinforcements, concrete around expansion &

grouted anchors, etc.)

130 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A3.3-a 3.5.1-24 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Metal Roofing & Structural Galvanized Atmosphere/ Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 581, C Siding - Support for Weather (Ext) Program Switchgear & Regulated Safeguard Bus - Events Carbon Steel, Exposed (flashing) 131 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Missile Shield - Missile Barrier Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A Yard - Concrete, Weather (Ext) Properties Program Exposed (Tank vault roof, pavement over buried piping)

III.A3.1-f 3.5.1-20 A Cracking Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program Structural Monitoring III.A3.1-f 3.5.1-20 A Program 132 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Tank Structural Concrete Soil (Ext) Loss of Material None Required III.A8.1-a 3.5.1-20 571, A Foundations - Support for Building & Yard - Regulated Concrete, Below Events Grade Structure (concrete Functional foundation) Support III.A8.1-e 3.5.1-21 544, A Change in Material None Required III.A8.1-b 3.5.1-20 557, A Properties III.A8.1-e 3.5.1-21 544, A Cracking and None Required III.A8.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A8.1-d 3.5.1-21 544, A Bond/Matl 133 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking None Required III.A8.1-f 3.5.1-25 547, A Tank Structural Concrete Atmosphere / Cracking Structural Monitoring III.A8.1-a 3.5.1-20 A Foundations - Support for Weather Program Building & Yard - Regulated Concrete, Events Exposed Structural (concrete Support for foundation) Safety Related Loss of Material Structural Monitoring III.A8.1-a 3.5.1-20 A Program Change in Material Structural Monitoring III.A8.1-b 3.5.1-20 A Properties Program Cracking and Structural Monitoring III.A8.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A8.1-d 3.5.1-21 A Bond/Matl Program 134 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 135 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Carbon Steel Plant Indoor air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 A

- Boiler Buildings Support for (Ext) Program Area - Carbon Non-Safety Steel, Protected Related (column, hanger, beam, truss,

decking, platform, floor grating or plate,
catwalk, threaded
fastener, concrete expansion bolt, column base plate, welds, etc.)

136 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Boiler Buildings Support for Area - Concrete, Non-Safety Below Grade Related (wall, pedestal, grade beam,

footing, foundation, slab,
grout, reinforcement, cable pits, tunnels, etc.)

III.A3.1-g 3.5.1-21 544, A Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl 137 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing Structural Concrete Atmosphere / Cracking Structural Monitoring III.A3.1-a 3.5.1-20 A

- Boiler Buildings Support for Weather (Ext) Program Area - Concrete, Non-Safety Exposed Related (foundations, masonry/

concrete wall,

grout, reinforcements, concrete around expansion &

grouted anchors, etc.)

III.A3.1-h 3.5.1-25 A III.A3.3-a 3.5.1-24 A Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A 138 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A Properties Program III.A3.1-f 3.5.1-20 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 139 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Plant Indoor Air Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A

- Boiler Buildings Support for (Ext) Program Area - Concrete, Non-Safety Protected Related (foundations, concrete &

masonry wall, column, beam, floor/roof slab,

grout, reinforcements, concrete around expansion &

grouted anchors, etc.)

Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program 140 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking Structural Monitoring III.A3.1-h 3.5.1-25 A Program III.A3.3-a 3.5.1-24 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 141 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Flood Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, A

- Carbon Steel, Protection (Ext) Program Protected HELB (column, beam, Shielding truss, decking, Pipe Whip platform, floor Restraint grating or plate, catwalk, bracing, Shelter/

threaded Protection

fastener, Structural concrete expansion bolt, Support for column base Non-Safety Related plate, welds, etc.) Structural Support for Regulated Events Structural Support for Safety Related 142 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Concrete, Support for Below Grade Non-Safety Related (wall, pedestal, grade beam, Structural footing, Support for foundation, slab, Regulated grout, Events reinforcement, Structural cable pits, Support for tunnels, etc.)

Safety Related III.A3.1-g 3.5.1-21 544, A Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl 143 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing Flood Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A

- Concrete, Protection Weather (Ext) Properties Program Exposed Shelter/

(foundations, Protection masonry/

Structural concrete wall, Support for

grout, Non-Safety reinforcements, Related concrete around expansion & Structural grouted anchors, Support for etc.) Regulated Events Structural Support for Safety Related III.A3.1-f 3.5.1-20 A 144 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Program III.A3.1-a 3.5.1-20 A III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 145 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Flood Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A

- Concrete, Protection (Ext) Program Protected HELB (foundations, Shielding concrete &

Missile Barrier masonry wall, column, beam, Shelter/

floor/roof slab, Protection

grout, Structural reinforcements, Support for concrete around expansion & Non-Safety grouted anchors, Related etc.) Structural Support for Regulated Events Structural Support for Safety Related III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program 146 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Building Framing Expansion / Bronze Plant Indoor Air Loss of Material None Required III.A4.2-b 3.5.1-20 586, I N/A N/A A, 586,

- Sliding Separation (Ext) 5004

Material, Protected (vertical supports with sliding surfaces) 147 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, A

- Water Support for (Ext) Program Treatment Area - Non-Safety Carbon Steel, Related Protected Structural (column, beam, Support for bracing, Regulated threaded Events fastener, weld, etc.)

Building Framing Structural Concrete Soil (Ext) Loss of Material None Required III.A3.1-a 3.5.1-20 571, A

- Water Support for Treatment Area - Non-Safety Concrete, Below Related Grade Structural (wall, pedestal, Support for grade beam, Regulated footing, Events foundation, slab,

grout, reinforcement, trenches, cable pits, tunnels, etc.)

148 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A3.1-g 3.5.1-21 544, A Change in Material None Required III.A3.1-b 3.5.1-20 557, A Properties III.A3.1-g 3.5.1-21 544, A Cracking and None Required III.A3.1-c 3.5.1-20 543, A Expansion Cracking, Loss of None Required III.A3.1-e 3.5.1-21 544, A Bond/Matl Cracking None Required III.A3.1-h 3.5.1-25 547, A 149 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A

- Water Support for Weather (Ext) Properties Program Treatment Area - Non-Safety Concrete, Related Exposed Structural (foundations, Support for wall, grout, Regulated reinforcements, Events concrete around expansion &

grouted anchors, etc.)

III.A3.1-f 3.5.1-20 A Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Program III.A3.1-a 3.5.1-20 A III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program 150 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity 151 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Building Framing Structural Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A

- Water Support for (Ext) Program Treatment Area - Regulated Concrete, Events Protected Structural (foundations, Support for concrete/ Non-Safety masonry wall, Related beam, floor slab,

grout, reinforcements, concrete around expansion &

grouted anchors, etc.)

III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program 152 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Structural Monitoring III.B5.2-a 3.5.1-29 A Concrete Anchor Program Capacity Flood Barrier - Flood Carbon Steel Plant Indoor Air Loss of Leak Structural Monitoring III.A3.2-a 3.5.1-20 531, H N/A N/A N/A Carbon Steel, Protection (Ext) Tightness Program Protected Structural (flood doors, Support for hatch, Safety standpipe) Related Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program 153 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HELB/MELB Flood Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, C Component - Protection (Ext) Program Carbon Steel, HELB Protected Shielding (curbs, floor Pipe Whip drains, pipe whip Restraint restraints, spray shields, etc.) Structural Support for Safety Related HELB/MELB Flood Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Protection (Ext) Program

Concrete, HELB Protected Shielding (concrete/

Pipe Whip masonry wall, Restraint whip restraint grout, concrete around expansion &

grouted anchors, etc.)

Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program 154 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program HVAC Fluid Carbon Steel Plant Indoor Air Loss of Leak Structural Monitoring III.A3.2-a 3.5.1-20 533, H N/A N/A N/A Component - Pressure (Ext) Tightness Program Carbon Steel, Boundary Protected Structural (Control Room Support for vestibule door) Non-Safety Related Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 580, C Program 155 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes HVAC Fluid Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Pressure (Ext) Program Concrete, Boundary Protected Structural (Control Room Support for vestibules, Non-Safety concrete & Related masonry walls, floors, ceilings)

III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program 156 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Missile Shield - Missile Barrier Concrete Atmosphere/ Change in Material Structural Monitoring III.A3.1-b 3.5.1-20 A concrete, Weather (Ext) Properties Program Exposed (concrete and/or masonry walls protecting CCW room door and containment escape hatch III.A3.1-f 3.5.1-20 A Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Program III.A3.1-a 3.5.1-20 A III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program 157 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Structural Monitoring III.A3.1-a 3.5.1-20 A Program III.A3.1-f 3.5.1-20 A Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program Missile Shield - Missile Barrier Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.1-h 3.5.1-25 A Concrete, (Ext) Program Protected (concrete/

masonry walls, floor, & roof protecting Control Room Door)

Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program 158 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program Operator Access Structural Carbon Steel Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 A Component - Support for (Ext) Program Carbon Steel, Non-Safety Protected Related (stairs, floors, Structural platforms) Support for Regulated Events Operator Access Structural Concrete Plant Indoor Air Cracking Structural Monitoring III.A3.3-a 3.5.1-24 A Component - Support for (Ext) Program Concrete, Non-Safety Protected Related (stairs, floors, Structural platforms, Support for concrete at Regulated locations of Events expansion &

grouted anchors, etc.)

159 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Rev 1 NUREG -

Rev 1 1801 NUREG - NUREG - Volume 1 Rev 1 Aging Effect 1801 1801 Table Row NUREG Component Intended Requiring Aging Management Volume 2 Table 1 Volume 2 (Table # - - 1801 Type Function Material Environment Management Programs Line Item Item Notes Line Item Row #) Notes III.A3.1-h 3.5.1-25 A Cracking and Structural Monitoring III.A3.1-c 3.5.1-20 A Expansion Program Cracking, Loss of Structural Monitoring III.A3.1-d 3.5.1-20 A Bond/Matl Program Loss of Material Structural Monitoring III.A3.1-f 3.5.1-20 A Program Loss of Strength Structural Monitoring III.A3.1-b 3.5.1-20 A Program Reduction in Conc Structural Monitoring III.B5.2-a 3.5.1-29 A Anchor Capacity Program Operator Access Structural Galvanized Plant Indoor Air Loss of Material Structural Monitoring III.A3.2-a 3.5.1-20 581, A Component - Support for (Ext) Program Galvanized, Non-Safety Protected Related (stairs, floors, Structural platforms) Support for Regulated Events 160 of 161

Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports Civil /Structural Precedent Review Plant Specific Notes:

NOTE: See Notes for Tables 3.5.2-1 through 3.5.2-10 (immediately following Table 3.5.2-10) of the Palisades License Renewal Application for list of Standard (A through J) and Plant Specific Notes (5XX series). Below are plant specific notes related to the Precedent Review of Tables 3.5.2-1 through 3.5.2-10.

N/A No precedent found. In cases where another plant's SER is cited in the Note column as a precedent using notes 5000 through 5004, a standard letter note is provided to facilitate NRC review assignments. In these cases, the letter note should be interpreted as an indicator of Palisades' consistency with the cited precedent (and, therefore, still subject to audit team review), and not to indicate consistency with Revision 1 of NUREG 1801.

5000. Precedents for built up roofing exist in the following Safety Evaluation Reports:

  • Dresden/Quad Cities, NUREG 1796, Section 3.5.2.4.2
  • McGuire/Catawba, NUREG 1772, Section 3.5.2.1 5001. Loss of Material due to abrasion is the aging effect and mechanism evaluated and being managed by Palisades. It is considered sufficiently similar to GALL aging effect/mechanism of Increased hardness, shrinkage and loss of strength / weathering since separation from the protected component is the end result of both. The Fire Protection Program is consistent with GALL with exceptions, resulting in a standard note B.

5002. The Safety Evaluation Report (SER) for Dresden/Quad Cities, NUREG 1796, provides a precedent in Section 3.3.2.4.5 for fire wraps. Dresden/Quad Cities fire wraps are ceramic fiber with an aging effect/mechanism of separation/deterioration of metal. Palisades fire wrap components consist of rigid cementitious or fibrous material as well as cable tray insulation covers. Palisades aging effects/mechanisms of cracking due to vibration and loss of material due to abrasion results in the same aging effect of separation from the protected component. The Fire Protection Program is consistent with GALL with exceptions, resulting in a standard note B.

5003. The Safety Evaluation Report (SER) for Dresden/Quad Cities, NUREG 1796, provides a precedent in Section 3.5.2.4.2 for elastomers/roofing. Dresden Quad Cities aging effects/mechanisms of hardening cracking/elastomers degradation and change in material properties/loss of resiliency, loss of strength, loss of elasticity match well with Palisades cracking/thermal exposure and change in material properties/thermal exposure.

5004. The Safety Evaluation Report (SER) for H. B. Robinson, NUREG 1785, provides a precedent in Section 3.5.2.4.1.2 for no aging effects for bronze/Lubrite.

Similar to H. B. Robinson, Palisades' past ISI inspections of the Steam Generator and Primary Coolant Pump supports have identified no recordable degradation of Lubrite sliding plates.

161 of 161