Final Status Survey Release Record Southwest Site Storage Area Survey Unit 9520-003.
ML063540232
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/26/2006
From: McCarthy J
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
Download: ML063540232 (236)


Text

CYAPCO FINAL STATUS SURVEY RELEASE RECORD SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 Prepared By: Reviewed ByL Approved By: Date: 1/Z/c g Date: Date: 1/ .,A6 Revision 0 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

....................................................

3 2. CLASSIFICATION BASIS .............................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ........................................

5 4. SURVEY DESIGN ...........................................................................

8 5. SURVEY IMPLEMENTATION

....................................................

11 6. SURVEY RESULTS ......................................................................

12 7. QUALITY CONTROL ....................................................................

16 8. INVESTIGATIONS AND RESULTS ............................................

16 9. REMEDIATION AND RESULTS ....................................................

17 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .........

17 11. DATA QUALITY ASSESSMENT (DQA) ....................................

17 12. A N O M A LIE S .................................................................................

18 13. CON CLU SION ...............................................................................

18 14. ATTA CHM EN TS ..........................................................................

19 14.1 Attachment 1 -Figures (6 pages including cover)14.2 Attachment 2 -Scan Results (6 pages including cover)14.3 Attachment 3 -Laboratory Data (190 pages including cover)14.4 Attachment 4 -DQA Results (15 pages including covers)TOTAL 236 Revision 0 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD 1. SURVEY UNIT DESCRIPTION Survey Unit 9520-0003 (Southwest Site Storage Area) is designated as Final Status Survey (FSS) Class 2 and consists of 8,106 m2 (2.0 acres) of uninhabited open land located approximately 1,661 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9520-0002 to the north (called north as oriented with the north to south flow of the Connecticut River), the Discharge Canal to the east, land Survey Unit 9530-0004 to the south, and the Connecticut River to the west. The survey unit is relatively level open space in the middle of the peninsula.

The restoration of the peninsula for FSS has removed most of the surface interference in the survey unit.The reference coordinates associated with this survey unit are E005 through E010 by S086 through S093 (refer to License Termination Plan (LTP) Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification.

" The "Classification Basis Summary" conducted for Survey Unit 9520-0003 consisted of: a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." A review of the 1OCFR50.75(g)(1) database report and historical files shows a documented history of the use of this survey unit as a radioactive materials storage area. Additionally, at least one (1) case of contamination to underlying soil has been recorded (refer to survey performed 3/23/1985).

Examples of some of the major events are provided below.a) Plant Incident Report (PIR) 80-37 reported the discovery of three (3)discrete sources of elevated activity on the Southeast Site Storage area in March 1980, along with other areas around the site. Two (2) of the discrete sources were identified within nearby Survey Unit 9520-0001.

The location of the third discrete source, identified as 3-24-2, was probably in Survey Unit 9520-0002, which is adjacent to Survey Unit 9520-0003, based on a review of the 1980 survey maps.Revision 0 3 Revision 0 3 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD b) Health Physics surveys performed in 1983 and 1985 document the discovery of radioactive material (strainers, bolts, wood pallets, sections of pipe, etc.) on the peninsula.

The 1985 survey documents the discovery of contaminated dirt under a pallet.c) Condition Report (CR) 05-0314: Documents the discovery of excavation spoils, intended for backfill, above the radiological criteria for use as backfill.

These spoils were likely located in Survey Units 9520-0003 and 9520-0004 based on review of the documentation.

According to the CR closure documentation, the affected spoils were removed and packaged for disposal.

Follow-up survey and sampling was performed and the results were below established action levels.A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed.

Survey Unit 9520-0003 was initially designated as Class 2 during the development of the LTP. The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0 (references 2-2 and 2-7 respectively).

The second source document justified a Class 2 designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGLs -refer to Section 2 for definition and description of DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class 2 designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".

Removal of material and restoration of the peninsula for FSS has been ongoing since 2000, starting with the radiological release of the South Access Point and several abandoned trailers.

The collapse of the Radioactive Material(s)

Area (RMA) boundary and the removal of subsurface commodities has produced a large data set that has helped/characterize the radiological contaminants of concern and extent of contamination.

Co-60 has been identified in the past (refer to the "Haddam Neck Plant Historical Site Assessment Supplement"), and has the potential to exceed the screening criteria (refer to Section 3).Characterization was performed in August 2006 to support final classification and FSS planning.

Statistical quantities (mean, median and standard deviation) from the 2006 characterization survey conducted under SSWP 06-07-006 are provided in Table 1.Revision 0 4 Revision 0 4 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD serveu %-oncentraton kpLi/g) : Maximum Observed Concentration (pCi/g): 1.03E-01 1.41E-01 Mean (pCi/g): 6.63E-02 1.96E-02 Median (pCi/g): 6.86E-02 -2.93E-03 Standard Deviation (pCi/g): 3.74E-02 5.96E-02 The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the results of radiological surveys performed over six years of restoration and the 2006 characterization survey, it was concluded that there was a low probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 2 (refer to Section 3).3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.

Therefore, the survey unit does satisfy the primary objective of the FSS plan.The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9520-0003 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).Revision 0 5 Revision 0 5 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation I HTotal =Hsoi +/-+HExistingGW

+HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.Equation 2 19 mrem/yrTotal

= 17 mrem/yrsoil

+ 2 mrem/yrExisting GW+ 0 mrem/yrFutureGw The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Revision 0 6 Revision 0 6 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORDý F -.,;;I H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 0E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-0 1 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-0I Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241,5) 2.58E+O1 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 I ) Bold inuicates Mose radionucliles consiaerea to ne ilara-to-Detect (JI I U)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to 1 mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Soil samples were collected in 2006 to establish the radiological condition of Survey Unit 9520-0003 for FSS. Cs-137 and Co-60 are the only gamma emitting radionuclides reported in concentrations with the potential for exceeding the screening criteria.

The characterization data were used for the survey design and are provided in Table 1.Revision 0 7 Revision 0 7 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans". The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.The DQO process determined that Cs-137 and Co-60 would be the radionuclides of concern in Survey Unit 9520-0003 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.95 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Revision 0 8 Revision 0 8 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and five (5) samples at biased locations.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area. Two of the sample locations, 9520-0003-009F and 9520-0003-01OF, were selected randomly since the systematic locations fell within the boundary of Survey Unit 9520-0004, a Class 1 survey unit contained within Survey Unit 9520-0003.

Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.T'Ible 3>.Sam ple Meaureni i~Locations with Associated GP'S Coordin'ates~

9520-0003-OOIF 235740.79 669643.56 9520-0003-003F 235654.02 669693.65 9520-0003-004F 235654.02 669793.84 9520-0003-005F 235654.02 669894.03 9520-0003-006F 235654.02 669994.22 9520-0003-007F 235654.02 670094.41 9520-0003-008F 235567.26 669643.56 9520-0003-009F 235487.99 669999.66 9520-0003-011OF 235540.74 670070.44 9520-0003-01 IF 235567.26 669944.12 9520-0003-012F 235567.26 670044.31 9520-0003-013F 235480.49 669793.84 Revision 0 9 Revision 0 9 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD Table 3 -Sample Measurement

~Locations w~ith AsoitdGS oriae Desgnation Northingi ahing 9520-0003-014F 235480.49 669894.03 9520-0003-015F 235480.49 669994.22 9520-0003-016F 235575.69 669956.27 9520-0003-017F 235550.58 669950.98 9520-0003-018F 235630.38 669849.11 9520-0003-019F 235707.61 669714.28 9520-0003-020F 235544.37 669657.91 9520-0003-039F (1) 235604.73 669995.37 (1) Sample 9520-0003-039F was added to the FSS plan to replace sample 9520-0003-002F, which was reassigned to adjacent Class I Survey Unit 9520-0005 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis.

Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel"RANDBETWEEN" function.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12,"Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RANDBETWEEN" function.

The number of quality control soil samples was about 10% of fifteen (15) samples.The LTP specifies a required scanning coverage of 10% to 100% for outdoor Class 2 areas. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in six (6)separate areas. The total surface area to be scanned was approximately 20% of the survey unit.Revision 0 10 Revision 0 10 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.Table 4 -~ Synopsis of tlwiSu vey Desion Feature , Design Criteria Basis Survey Unit Land Area 8,106 m2 Based on AutoCAD-LT Type 1 and Type 2 errors were 20 0.05, sigma was 0.029 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 0.95 (5 biased) to maintain Relative Shift in the range of I and 3 Grid Spacing 25.0 m Based on triangular grid 5.38 pCi/g Cs-137 Administratively set to achieve 2.59 pCi/g Co-60 17 mrem/yr TEDE (1)(2)e 5.38 pCi/g Cs-137 The Operational DCGL meets Soil Investigation Level pCi/g Cthe LTP criteria for a Class 2 2.59 pCi/g Co-60 survey unit (2)Scan Survey Area Approximately 20% The LTP requires >10% area eof the area coverage for Class 2 survey units Detectable over Administratively set to achieve background 17 mrem/yr TEDE (1)(1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)(2) In conjunction with the unity rule 5. SURVEY IMPLEMENTATION FSS field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.

The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Six (6) scan areas were established that constituted approximately 20% of the surface area of Survey Unit 9520-0003.

Grid lines, one meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 5,580 counts per minute (cpm) up to 9,920 cpm.The scan areas were established and scanned for elevated readings (see Attachment 2 for all scan results).

Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector.

The E-600 was operated in the rate-Revision 0 I1I Revision 0 11 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD meter mode and used with audio response.

The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 20% of the survey unit was scanned.Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.

At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.Twenty-four (24) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5,"Chain of Custody for Final Status Survey Samples." Two (2) samples (9520-0003-010F and 9520-0003-039F) were randomly selected for HTD radionuclide analysis.

Sample 9520-0003-039F replaced sample 9520-0003-002F, which was reassigned to another survey unit (refer to Section 10 for additional detail).The implementation of survey specific quality control measures included the collection of two (2) samples (9520-0003-004F and 9520-0003-014F) for "split sample" analysis.6. SURVEY RESULTS All field survey activities were conducted between September 25, 2006 and October 4, 2006.The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations.

Scan results are provided in Attachment

2. I IN u 3 5.08 6.10 NO 4 6.57 7.50 NO 5 7.01 7.49 NO 6 7.65 8.19 NO 7 7.70 8.83 NO 8 6.21 7.71 NO Revision 0 12 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD 9 7.28 8.48 NO 10 7.32 8.88 NO 11 6.65 8.62 NO 12 7.56 8.86 NO 13 6.44 7.37 NO 14 7.23 9.01 NO 15 7.88 8.34 NO 16 6.91 9.94 NO 17 7.40 8.74 NO 18 5.82 7.32 NO 19 6.39 8.37 NO 20 6.13 7.68 NO 39 (3) 6.56 7.86 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level (3) Sample location 9520-0003-039F replaced sample location 9520-0003-002F which was reassigned to Survey Unit 9520-0005 The scan areas, that comprised approximately 20% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on September 26, 2006 through October 2, 2006. Several elevated measurement locations were identified during scanning.

One elevated area warranted analysis on-site since it was twice ambient background.

The gamma spectroscopy result reported Co-60 above the Operational DCGL. A new Class 1 survey unit was created around the area of elevated activity (refer to Section 10). Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.Revision 0 13 Revision 0 13 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD I 7.90 9.17 iNone -no elevated areas identified None None -no 2 6.97 8.82 elevated areas None identified None -no 3 6.41 7.56 elevated areas None identified 9520-03-ER 06-1 9520-0003-035F 06-1 9520-03-ER 9520-0003-036F 4 10.5 7.23 08-1 9520-03-ER 9520-0003-037F 10-1 9520-03-ER 9520-0003-038F 12-1 None -no 5 8.68 10.3 elevated areas None identified None -no 6 8.90 9.18 elevated areas None identified (1) Most of scanning performed in scan area 1 and scan area 2 is now relevant to Survey Unit 9520-0005 (refer to Section 10).(2) The action level is based on a measurement above ambient background (3) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the five (5) biased samples, and the four (4) confirmatory samples using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).

However, Cs-137 and Co-60 were the only radionuclides reported in concentrations exceeding the de-selection criteria.Cs-137 was identified in thirteen (13) of the fifteen (15) samples collected for non-parametric statistical testing. Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results Revision 0 14 Revision 0 14 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

Co-60 was identified in three (3) of the fifteen (15) samples collected for non-parametric statistical testing.A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.9520-0003-003F 5.54E-02 1.42E-02 0.016 9520-0003-004F 2.45E-02 1.33E-02 0.010 9520-0003-005F 1.07E-01 1.78E-02 0.027 9520-0003-006F 6.53E-02 1.94E-02 0.020 9520-0003-007F 1.37E-01 -4.29E-03 0.025 9520-0003-008F 1.99E-01 5.69E-03 0.039 9520-0003-009F 1.71E-01 -5.58E-03 0.032 9520-0003-01OF 4.59E-02 2.48E-02 0.018 9520-0003-01IF 5.77E-02 1.5 1E-02 0.017 9520-0003-012F 2.75E-02 6.71 E-03 0.008 9520-0003-013F 2.80E-02 -8.93E-03 0.005 9520-0003-014F 1.14E-01 1.97E-02 0.029 9520-0003-015F 1.55E-01 1.22E-02 0.034 9520-0003-039F 5.30E-02 -2.5 1E-02 0.010 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.

None of the HTDs, which by analysis, met the criteria for detection (i.e., a result greater than two standard deviations uncertainty).

Revision 0 15 Revision 0 15 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD Five (5) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation.

Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.Tabl 8T -Judgmental or Biased Sample Resu Its Cs-137Co-00 raction (of the Saim ple Number pS~13/fC-6 Operational 9520-0003-016F 3.25E-02 6. 31E-03 0.008 9520-0003-017F 4.37E-02 1. 14E-02 0.013 9520-0003-018F 3.26E-02 6.29E-04 0.006 9520-0003-019F 1.78E-01 4.63E-03 0.035 9520-0003-020F 2.05E-01 3.79E-02 0.053 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 used in conjunction with the unity rule to achieve 17 mrem/yr TEDE 7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". Cs-137 was not detected in sufficient quantities in the field split results at location 9520-0003-004 to evaluate in accordance with procedure.

Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split result at this location.

Cs-137 was not detected in one of the field split results at location 9520-0003-0014.

Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split result at this location.The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation.

Refer to Attachment 4 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS Four confirmatory samples were collected from scan area 4 at locations exhibiting elevated scan readings.

The samples are denoted as shown in Table 6, with the sample results shown in Table 9 below.9520-0003-036F 4.99E-02 2.25E-02 0.018 Revision 0 16 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD 9520-0003-038F 1.24E-01 8.88E-03 0.026 (1) Samples 9520-0003-021F through 9520-0003-034F were reassigned to Class I Survey Unit 9520-0005 (refer to Section 10)(2) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 used in conjunction with the unity rule to achieve 17 mrem/yr TEDE 9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN One elevated area warranted analysis on-site since the scan measurement was twice ambient background.

The gamma spectroscopy result reported Co-60 above the Operational DCGL. Additional scanning did not identify other elevated areas indicating that the extent of contamination was localized to an area of about 36 square inches (six inches by six inches). A new Class 1 survey unit, Survey Unit 9520-0005, was created based on the sample result around the area of elevated activity and within the borders of Survey Unit 9520-0003.

The change to the FSS plan included the generation of a new sample location to complete the fifteen (15) samples for non-parametric statistical sampling.

The sample location was determined randomly using VSP. Also, most of scanning performed in scan area 1 and scan area 2 is now relevant to Survey Unit 9520-0005. The scanning that was performed in scan area 1 and scan area 2 did not identify elevated areas of activity; and, along with the other four scan areas, the minimum land area to be scanned (>10%) was satisfied for this survey unit.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.Revision 0 17 Revision 0 17 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2 after the new Class 1 survey unit (9520-0005) was created.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was about 27% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 0.44.Co-60, although included in the FSS plan for compliance purposes, was identified in only three (3) of the fifteen (15) samples collected for non-parametric statistical testing. Data assessment and graphical representation of Co-60 was not considered useful given the limited number of data points to represent the distribution.

All data, assessments, and graphical representations for Cs-137 are provided in Attachment 4.12. ANOMALIES A discrete source of elevated activity was identified during scanning as discussed in Section 10. A new Class 1 survey unit, Survey Unit 9520-0005, was created based on the soil sample result.13. CONCLUSION Survey Unit 9520-0003 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Elevated Measurement Comparison and remediation was not required.Cs-137 and Co-60 were used for statistical testing to determine the adequacy of the survey unit for FSS.The sample data passed the Sign Test. The null hypothesis was rejected.

The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit is properly designated as Class 2.Revision 0 18 Revision 0 18 SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0003 RELEASE RECORD The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE. Therefore, Survey Unit 9520-0003 is acceptable for unrestricted release.14. ATTACHMENTS 14.1 Attachment I -Survey Unit Location Map 14.2 Attachment 2 -Scan Results 14.3 Attachment 3 -Laboratory Results 14.4 Attachment 4 -DQA Results Revision 0 19 Revision 0 19 CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 1 (FIGURES)

.-0/I ROM 0wc COovc"00 Sjet~fi 86"OdNw*NWthh' _ 236;594 3g / Eaetkl9 66836f.14 Y 9_rcommECy~cur prvER-r& Connecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9520-0003

= WatLand Searlei OI-Desda i associte w#5-Azta no Survey Urnk 99504113 0 37.5 75 , IFeet Note, Sawp1alamtin

  1. 39 wa addeddto ffemmny drn~v Connecticut Yankee Atomic Power Company Survey Unit 9520-0003 Final Staus Survey Design

=Wet Las-ma N-wbwwith sovey Unf 9S2a~0 37.5 75 , IFeet 0.17 0.16 0.06 Nofte Repoite GOOncnM&Bonsin PaiVg 0.11 0.20 c~r Connecticut Yankee Atomic Power Company Survey Unit 9520-0003 Final Staus Survey Cs-137 Posting Plot r- = WatLand=Anounot smavavydmt

&"Wow00 37.5 75 , ; I Feet Notes A~M 5.6kqan ID 9.9 kcpn ddw fi by an 2-600 with SPA-3 ReihiOD7*bi6fbr-M MNr&Connecticut Yankee Atomic Power Company Survey Unit 9520-0003 Final Staus Survey Scan Amas Leged-Wet Lad--A a.t&zWy URNt 6 9~-42-0 37.5 75 Fedt Notes Re~flrh Table9ftw RPefo 7Mkble 0 for-ý20 Sawpks 2 1-34 w=i iwsaignedto Owl Survy Unk 952040WN5 Connecticut Yankee Atomic Power Company Dat By Survey Unit 9520-0003 Final Status Survey Biased and Con finnory Samples November 2006 .McCarthy CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9520-0003 Sample Name Background Action Level Results Above Log Date Log Time E600 S/N Probe S/N (cPm) 1cpm) (cDrM) AL 9520-03-SL-00-01-0 7.49E+03 8.73E+03 7.65E+03 9/26/2006 8:44:00 1114 1014 9520-03-SL-00-03-0 5.08E+03 6.10E+03 5.08E+03 9/25/2006 9:54:00 1114 1014 9520-03-SL-00-04-0 6.36E+03 7.50E+03 6.57E+03 9/25/2006 10:06:00 1114 1014 9520-03-SL-00-05-0 6.35E+03 7.49E+03 7.01E+03 9/25/2006 14:50:00 1114 1014 9520-03-SL-00-06-0 7.OOE+03 8.19E+03 7.65E+03 9/25/2006 14:09:00 1114 1014 9520-03-SL-00-07-0 7.59E+03 8.83E+03 7.70E+03 9/25/2006 15:29:00 1114 1014 9520-03-SL-00-08-0 6.55E+03 7.71E+03 6.21E+03 9/25/2006 15:04:00 1114 1014 9520-03-SL-00-09-0 7.26E+03 8.48E+03 7.28E+03 9/25/2006 13:53:00 1114 1014 9520-03-SL-00-10-0 7.63E+03 8.88E+03 7.32E+03 9/25/2006 13:43:00 1114 1014 9520-03-SL-00-11-0 7.39E+03 8.62E+03 6.65E+03 9/25/2006 11:10:00 1114 1014 9520-03-SL-00-12-0 7.61E+03 8.86E+03 7.56E+03 9/25/2006 13:32:00 1114 1014 9520-03-SL-00-13-0 6.24E+03 7.37E+03 6.44E+03 9/26/2006 8:15:00 1114 1014 9520-03-SL-00-14-0 7.75E+03 9.01E+03 7.23E+03 9/26/2006 8:24:00 1114 1014 9520-03-SL-00-15-0 7.13E+03 8.34E+03 7.88E+03 9/25/2006 13:54:00 1114 1014 9520-03-SL-00-16-0 8.61E+03 9.94E+03 6.91E+03 9/25/2006 11:12:00 1114 1014 9520-03-SL-00-17-0 7.50E+03 8.74E+03 7.40E+03 9/25/2006 11:15:00 1114 1014 9520-03-SL-00-18-0 6.20E+03 7.32E+03 5.82E+03 9/25/2006 10:08:00 1114 1014 9520-03-SL-00-19-0 7.16E+03 8.37E+03 6.39E+03 9/25/2006 9:59:00 1114 1014 9520-03-SL-00-20-0 6.53E+03 7.68E+03 6.13E+03 9/25/2006 15:17:00 1114 1014 9520-03-SL-00-39-0 6.69E+03 7.86E+03 6.56E+03 10/4/2006 13:31:00 1105 1012 Sample location 9520-03-SL-00-39-0 replaced sample location 9520-03-SL-00-02-0 which was reassigned to Survey Unit 9520-0005 AL -Action Level Survey Release Record Scan Area Results Survey Unit 9520-0003 9520-0003 SCAN AREA 1 Sample Name 9520-03-SC-02-01

-0 9520-03-SC-02-02-0 9520-03-SC-02-03-0 9520-03-SC-02-04-0 9520-03-SC-02-05-0 9520-03-SC-02-06-0 9520-03-SC-02-07-0 9520-03-SC-02-08-0 9520-03-SC-02-09-0 9520-03-SC-02-1 0-0 9520-03-SC-02-1 1-0 9520-03-SC-02-12-0 9520-03-SC-02-13-0 9520-03-SC-02-14-0 9520-03-SC-02-15-0 9520-03-SC-02-16-0 9520-03-SC-02-17-0 9520-03-SC-02-18-0 9520-03-SC-02-19-0 9520-03-SC-02-20-0 9520-03-SC-02-21

-0 9520-03-SC-02-22-0 Background (cpm)8.1OE+03 7.51 E+03 7.85E+03 8.26E+03 7.90E+03 8.39E+03 8.02E+03 7.90E+03 8.70E+03 9.33E+03 9.05E+03 5.95E+03 6.60E+03 6.91 E+03 7.57E+03 6.86E+03 7.43E+03 6.77E+03 6.52E+03 6.55E+03 6.55E+03 6.35E+03 Action Level (cpm)9.39E+03 8.75E+03 9.12E+03 9.56E+03 9.17E+03 9.70E+03 9.30E+03 9.17E+03 1.OOE+04 1.07E+04 1.04E+04 7.05E+03 7.76E+03 8.10E+03 8.81 E+03 8.04E+03 8.66E+03 7.94E+03 7.67E+03 7.71 E+03 7.71 E+03 7.49E+03 Results Above Loq Date Log Time E600 S/N Probe S/N (cpm 7.27E+03 7.20E+03 7.68E+03 7.27E+03 7.72E+03 7.62E+03 7.87E+03 7.90E+03 7.1OE+03 7.13E+03 7.36E+03 5.81 E+03 6.98E+03 6.89E+03 7.15E+03 6.81 E+03 7.21 E+03 6.38E+03 7.05E+03 7.1OE+03 6.60E+03 6.71 E+03 AL 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 9/27/2006 11:20:00 11:15:00 11:07:00 10:58:00 10:51:00 10:26:00 10:21:00 10:16:00 10:10:00 10:03:00 9:57:00 13:35:00 13:43:00 13:51:00 13:58:00 14:03:00 14:09:00 14:17:00 14:22:00 14:28:00 14:35:00 14:40:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 AL -Action Level Survey Release Record Scan Area Results Survey Unit 9520-0003 9520-0003 SCAN AREA 2 Sample Name 9520-03-SC-01-01-0 9520-03-SC-01-02-0 9520-03-SC-01-03-0 9520-03-SC-01-04-0 9520-03-SC-01-05-0 9520-03-SC-01-06-0 9520-03-SC-01-07-0 9520-03-SC-01-08-0 9520-03-SC-01-09-0 Background (CPM)5.86E+03 6.11E+03 6.37E+03 6.01E+03 7.04E+03 6.03E+03 7.41 E+03 7.58E+03 7.89E+03 Action Level (CPM)6.95E+03 7.23E+03 7.51 E+03 7.12E+03 8.24E+03 7.14E+03 8.64E+03 8.82E+03 9.16E+03 Results Above Log Date Log Time E600 SIN Probe SIN 5.98E+03 6.26E+03 5.66E+03 6.48E+03 6.38E+03 6.57E+03 5.42E+03 6.97E+03 6.35E+03 AL 9/26/2006 9/26/2006 9/26/2006 9/26/2006 9/26/2006 9/26/2006 9/26/2006 9/26/2006 9/26/2006 10:16:00 10:22:00 10:32:00 10:40:00 10:48:00 11:04:00 11:11:00 11:16:00 11:20:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 9520-0003 SCAN.AREA 3 Sample Name 9520-03-SC-03-01

-0 9520-03-SC-03-02-0 9520-03-SC-03-03-0 9520-03-SC-03-04-0 9520-03-SC-03-05-0 9520-03-SC-03-06-0 9520-03-SC-03-07-0 9520-03-SC-03-08-0 9520-03-SC-03-09-0 9520-03-SC-03-1 0-0 Background (CPM)6.52E+03 5.58E+03 6.73E+03 5.71 E+03 5.66E+03 6.42E+03 6.41 E+03 6.54E+03 6.33E+03 6.41 E+03 Action Level (CPM)7.67E+03 6.65E+03 7.90E+03 6.79E+03 6.73E+03 7.56E+03 7.55E+03 7.69E+03 7.47E+03 7.55E+03 Results Above Log Date Log Time E600 SIN Probe S/N IcPMJ AL 5.86E+03 5.66E+03 5.55E+03 5.73E+03 5.86E+03 6.41 E+03 5.68E+03 5.44E+03 5.80E+03 6.11E+03 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 8:02:00 8:06:00 8:11:00 8:19:00 8:27:00 8:31:00 8:35:00 8:39:00 8:43:00 8:46:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 AL -Action Level Survey Release Record Scan Area Results Survey Unit 9520-0003 9520-0003 SCAN AREA 4 Sample Name 9520-03-SC-04-01

-0 9520-03-SC-04-02-0 9520-03-SC-04-03-0 9520-03-SC-04-04-0 9520-03-SC-04-05-0 9520-03-SC-04-06-0 9520-03-ER-04-06-1 9520-03-SC-04-07-0 9520-03-SC-04-08-0 9520-03-ER-04-08-1 9520-03-SC-04-09-0 9520-03-SC-04-1 0-0 9520-03-ER-04-1 0-1 9520-03-SC-04-1 1-0 9520-03-SC-04-12-0 9520-03-ER-04-12-1 9520-03-SC-04-13-0 9520-03-SC-04-14-0 9520-03-SC-04-15-0 9520-03-SC-04-16-0

Background

fCPM)7.64E+03 7.76E+03 7.40E+03 7.20E+03 7.38E+03 6.82E+03 6.82E+03 7.70E+03 6.97E+03 6.97E+03 7.16E+03 6.11 E+03 6.11 E+03 6.69E+03 7.71 E+03 7.71 E+03 6.68E+03 6.99E+03 6.62E+03 6.91 E+03 Action Level (C m)8.89E+03 9.02E+03 8.63E+03 8.41 E+03 8.61 E+03 8.OOE+03 8.OOE+03 8.95E+03 8.16E+03 8.16E+03 8.37E+03 7.23E+03 7.23E+03 7.86E+03 8.96E+03 8.96E+03 7.85E+03 8.18E+03 7.78E+03 8.1OE+03 Results Above Log Date Log Time E600 S/N Probe S/N 6.67E+03 7.27E+03 7.48E+03 7.40E+03 7.69E+03 7.34E+03 9.19E+03 6.65E+03 7.79E+03 1.OOE+04 6.80E+03 5.98E+03 1.05E+04 6.94E+03 6.89E+03 1.03E+04 6.88E+03 6.66E+03 6.45E+03 7.15E+03 AL 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006+ 9/29/2006 9/28/2006 9/28/2006+ 9/29/2006 9/28/2006 9/28/2006+ 9/29/2006 9/28/2006 9/28/2006+ 9/29/2006 9/28/2006 9/28/2006 9/28/2006 9/28/2006 14:42:00 14:40:00 14:37:00 14:34:00 14:31:00 14:27:00 7:22:00 14:22:00 14:18:00 7:27:00 14:12:00 15:00:00 7:33:00 15:03:00 15:05:00 7:35:00 15:08:00 15:11:00 15:14:00 15:16:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 AL -Action Level Survey Release Record Scan Area Results Survey Unit 9520-0003 9520-0003 SCAN AREA 5 Background Action Level Results Above Log Date Log Time E600 SIN Probe SIN Sample Name (cm (cpM) (cpm AL 9520-03-SC-05-01-0 8.32E+03 9.62E+03 7.80E+03 9/27/2006 7:58:00 1114 1014 9520-03-SC-05-02-0 8.39E+03 9.70E+03 8.58E+03 9/27/2006 8:02:00 1114 1014 9520-03-SC-05-03-0 8.43E+03 9.74E+03 8.27E+03 9/27/2006 8:04:00 1114 1014 9520-03-SC-05-04-0 8.93E+03 1.03E+04 8.44E+03 9/27/2006 8:08:00 1114 1014 9520-03-SC-05-05-0 8.48E+03 9.80E+03 8.1OE+03 9/27/2006 8:10:00 1114 1014 9520-03-SC-05-06-0 8.98E+03 1.03E+04 8.68E+03 9/27/2006 8:13:00 1114 1014 9520-03-SC-05-07-0 8.18E+03 9.47E+03 7.69E+03 9/27/2006 8:15:00 1114 1014 9520-03-SC-05-08-0 8.42E+03 9.73E+03 8.60E+03 9/27/2006 8:18:00 1114 1014 9520-0003 SCAN AREA 6 Background Action Level Results Above Log Date Log Time E600 SIN Probe SIN Sample Name (cpm) (cpm) (cpm) AL 9520-03-SC-06-01-0 7.81E+03 9.07E+03 8.21E+03 9/28/2006 10:09:00 1114 1014 9520-03-SC-06-02-0 7.91 E+03 9.18E+03 8.90E+03 9/28/2006 10:24:00 1114 1014 9520-03-SC-06-03-0 8.12E+03 9.41E+03 8.02E+03 9/28/2006 10:33:00 1114 1014 9520-03-SC-06-04-0 8.61 E+03 9.94E+03 7.95E+03 9/28/2006 10:46:00 1114 1014 9520-03-SC-06-05-0 9.92E+03 1.13E+04 7.63E+03 9/28/2006 10:52:00 1114 1014 9520-03-SC-06-06-0 8.77E+03 1.01E+04 8.80E+03 9/28/2006 10:57:00 1114 1014 9520-03-SC-06-07-0 8.14E+03 9.43E+03 8.14E+03 9/28/2006 11:04:00 1114 1014 9520-03-SC-06-08-0 8.04E+03 9.32E+03 7.88E+03 9/28/2006 11:08:00 1114 1014 AL -Action Level CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative 1 General Narrative for Connecticut Yankee Atomic Power Co.Work Order: 172875 SDG: MSR#06-1312 October 12, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on September 29, 2006 for analysis.

Shipping container temperatures were checked, documented, and within specifications.

The samples were delivered with proper chain of custody documentation and signatures.

All sample containers arrived without any visible signs of tampering or breakage.Sample Identification The laboratory received the following samples: Laboratory Identification 172875001 172875002 172875003 172875004 172875005 172875006 172875007 172875008 172875009 172875010 172875011 172875012 172875013 172875014 172875015 172875016 172875017 172875018 172875019 172875020 172875021 172875022 Sample Description 9520-0003-002F 9520-0003-003F 9520-0003-019F 9520-0003-004F 9520-0003-004FS 9520-0003-01 8F 9520-0003-01 IF 9520-0003-016F 9520-0003-017F 9520-0003-012F 9520-0003-OIOF 9520-0003-009F 9520-0003-015F 9520-0003-006F 9520-0003-005F 9520-0003-008F 9520-0003-020F 9520-0003-007F 9520-0003-013F 9520-0003-014F 9520-0003-014FS 9520-0003-00IF GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417 , 2040 Savage Road (29407)Phone (843) 556-8171 -Fa,,43) 766-1178 www.gel.com Items of Note There are no items to note.Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.Analytical Request Twen'ty soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.Data Package The enclosed data package contains the following sections:

General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions:

Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Chey MJones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171 -768-1178 www.gel.com List of current GEL Certifications as of 12 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FIJNELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4, Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00585 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab UseOnly w; -Contact Name & Phone: C,,.Omens:.

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 <843 556 8171. Attn. Cheryl Jones c/)Priority:

[] 30 D. Z 14 D. [II 7 D. [1 3 D. -Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample II)Code Code Code______- ______3__ ,r O TS G BP -ix*___ ___ __ ___ __ __ _ _ _ _ _ TS G BP _ _ _ _ _IU4 -_ _ b 3 -__ _ q r_ J6/a C.> TS G BP _________ _ __ _ __ _ _ -0 1 3 hLýý 410 J0 Is- TS G BP _ _-F'IS),' UUý3> ut.-/r5 92t/ /o/r TS G BP )(I_____750 -o0t)- oI0 1 Y- /0-h lo TS G BP L -____ --_______.___________

1s o -L .olj1 r -1/0? TY __ 1 5P V,ý 4 -OU) -0 11 P- I Ibr/16 Ii );o -t r, /9 r -g <<

: 01~-o-Ji Si' JL .& ________ ____v~-r~&-~rnI 6r1! IdGI I., Tf ____ _____ ________NOTES: PO #: 002332 009~v, MSR #: 06 i 3- SSWP# NA LTP QA El Radwaste QA [ Non QA o4o-t3 1) Relin hed7B Date/Time -deived By Date/Time 3) Relinquished By Date/Time
4) Received By Date/Time Samples Shipped Via: E Fed Ex L] ups[] Hand E] Other Bill of Lading #InternalContai ner:TemP.lO Deg<JCstody Sealed?Cu t y Sealt.Intact?y NL,"

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-00I F "gure I Sample Check-in List Date/Time Received:

q C )1.,.SDG#: .-Work Order Number -' * -Shipping Cdntainer lD :2-.-7 .J3O .. 2 i in of Custody# .. Q(P OO Q S 1. Custody Seals orf shipping container intact?:..

Yes No []2. Custody Seals dated and signed? Yes [ No 3. Chain-of-Custody record present? Yes No I 5. Vermiculite/packing materials is: Wet [ ] Dry 6' Number of samples in shipping container:

___;7. Sample holding times exceeded?.

Yes [ ] No 8. Samples have:-K -tape hazard labels_ custody seals -appropriate sample labels 9. Samples are: 4Iýin good condition -leaking-khave air bubbles 10. Were any anomalies.identified in sample receipt? Yes [ ] No 11. Description ofanomalies (include sample numbers): Sample Custodian/Laboratory:

' ..T p eB Date.Telephoned to: O B Il ------ --------7.

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00586 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Contact Name & Phone: Jack McCarthy 860-267-3924 Analyses Requested LA) tfse (on IS'CommnentsX:

Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

[] 30 D. E 14 D. [I 7 D. D] 3 D.0 CA CA<A Sample Designation Date Time Media Code Sample Type Code Container Size-&Type Code Comment, Preservation Wh 000-3 -0ISJ I /)'lo L f39a? TS G BP 7y>00ot- ~-a 0L-' / I9/Ii0k3)-

TS G BP I qý -TS G BP_ __ _IOyOO~~ Iy~o TS G BP 7S ý ~ou'3 -~ </./.t rJO TS G BP -_ __-~~~ S3i~rooJ 0I~j is$ r -__NOTES: PO #: 002332 MSR #: 0603 I SSWP# NA M LTP QA E] Radwaste QA ED Non QA 1) Rel] " 13 Date/Time

2) civedBDate/Time
3) Relinquished By Date/Time
4) eceivedBy Date/Time Samples Shipped Via:[ Fed Ex[] UPS El Hand ED Other Bill of Lading #Internal Coitainer' Temp.: ___Deg., Custody Sealed?4 Custody Sea[Intact?WY __ NE Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custodytorm No. 2006-00587 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Contact Name & Phone: Comnment s: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 , 843 556 8171. Attn. Cheryl Jones P rio rity : F] 3 0 D .E 14 D .[ _ 7 D .[ _ 3 D .C ontain r: Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Sample IDF Code Code Code 1l. o ',i/ TS G BP __ _ ___ ___ ______ .___Qu- 4t -/ -JIt/o. 0 ,")- TS G BP ___ 5:._ _ "_ _ _ _6 L/ FS' ,-AL 0o? -Ir TS G BP ____,__......_,___

,___Fv'oo- o003-0o1J[

q/ ,L 0-Y 1_/_ TS G BP X___ _......._ _._T__ _ _ Sh .' " Ts:...NOTES: PO #: 002332 MSR#:06- 3tZ SSWP#NA Z LTPQA E] RadwasteQA Li Non QA l) Re .q d y Date/Time

2) dDBy0 ate/Time Samples Shipped Via: 0 Fed Ex EL UPS Li Hand Li Other Bill of Lading #Internal Contai ner Temp.: __Deg~NC Custody Sealed Intact?Y C 3) Rýelinquishe'd By Date/Time 4) Aceived By Date/Time Connecticut Yankee "CY."ISC..SOW...O"1 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List Dateime Received:

3 SDG#:i Work Order Number: '"+2-. , , Shipping Cdntainer ID:,_ ýOO, 30 4'q J Chain of Custody# "x'7 LX.,S 3 ,2O. 1. Cus6djy Seals oti shipping container intact?:..

  • Yes tA No [")2. Custody Seals dated and signed? Yes[4 No ( ]3. Chain-of-Custody record present? Yes No ]4. Cooler temperature 2 -..5. Vermiculite/packing materials is:' Wet (] Dry 6.' Number of samples in shipping container:

i 3 .7. Sample holding times exceeded?

Yes [ No

  • 8. Smples have:.ltapehazard labels_.. custody seals -appropriate sample labels 9. Samples are: Y.-ngood condition -leaking broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes ( ] No U i 11. :,Description of anomalies (include sample numbers): Samrple. Custodian/Lab~oratory:

/ e Date- 7! oe?Telephoned to:ý______________

_______ ____________

____________________On B

SAMPLE RECEIPT & REVIEW FORM PM U.e e-y Clieat: Y A k, SDGIARCOC/Work OrdenaI~-3 I2 7 Date Received:

7/0 6 QPM(A) Review ( fure'uen-confirims itens are reolved prior to signing): Received By: W ons Sample Receipt Criteria Comnients/Qualllers (Required for Non-Conformlngit Ws)1Shipping containers received intact Cird Applicable:

seals broken damampd leaking r o0dr (describe) a1 Sealed?Sam s requiring cold Circle Cwoolar n ice bags bhue ice ic nom ofter describe)preserv 'on within -(4 +/- 2 CY?Record r ation method.Chain of custo documents included with shi' " .t?mlued with sient and CircleApplicable.

damaged container ainkt cominer otkc (describe)

~ apecontainers in Crl sealed?Samples requiring chemical sampic *omimn afected obsere pH.preservation at ro r H?VOA vials free of headspace Sample I'sand comiars affectd: (defined as < 6nrit bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laborato )Samples received within hold is aftewd: 8time?Sample ID's on COC h iD's Sample -' cominrs a on boules?Date & time on CC match date mple U's affectw: 10& time on bott s?2 Number o ontainers received Sample ID's affected match mber indicated on COC?12 C form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, & -7i00" <3 .9Lt } '.Additional Comments T2g RSO RAD Receipt#___________

S -*If> x2 area background is observed ousamples identified as 'non-Suspected Hazard Information i -i regulatedinon-radjoacwtve, contact the Radiation Safety group for further.cc___ __ EE investigation.

A jRadiological Classification? " _ Maximum Counts Observed*:

go _..MB Regulated?

-. , Comments:-.'Shlpped as lxIi Hazardous Class Shipp C iMaterial?

If yes, contact Waste NiNazCas Shipped:-]Manager or ESH Manager. AU I PM (or PMA) review of Hazard classification:

.1 iials Date: IS Data Review Qualifier Definitions 12 Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound c Result is less than value reported> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171 , FaLj33) 766-1178 www.gel.com RADIOLOGICAL ANALYSIS 14 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 172875 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578044 574186 574174 Sample ID 172875001 172875011 1201204515 1201204516 1201204517 1201204518 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172879001(9805-0000-008F)

Sample Duplicate (DUP)172879001(9805-0000-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

15 Guality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172879001 (9805-0000-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were reprepped due to high relative percent difference/relative error ratio.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 16 Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 574558 574186 574174 Sample ID 172875001 172875011 1201197066 1201197067 1201197068 1201197069 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172879001(9805-0000-008F)

Sample Duplicate (DUP)172879001(9805-0000-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.Designated QC The following sample was used for QC: 172879001 (9805-0000-008F).

QC Information All of the QC samples met the required acceptance limits.17 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I 1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 578046 Prep Batch Number: 574186 Dry Soil Prep GL-RAD-A-021 Batch Number: 574174 18 Sample ID Client ID 172875001 9520-0003-002F 172875011 9520-0003-OIOF 1201204519 Method Blank (MB)1201204520 172879001 (9805-0000-008F)

Sample Duplicate (DUP)1201204521 172879001(9805-0000-008F)

Matrix Spike (MS)1201204522 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172879001 (9805-0000-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 172875001 (9520-0003-002F) and 172875011 (9520-0003-010F) were reprepped due to high relative percent difference/relative error ratio.Miscellaneous Information:

NCR Documentation 19 Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 172875021 172875022 1201196539 1201196540 1201196541 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574336 574180 Client ID 9520-0003-014FS 9520-0003-00IF Method Blank (MB)172275028(9807-0000-025F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry 20 All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172275028 (9807-0000-025F).

QC Information Refer to Non-Conformance Report.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 368031 was generated due to Failed RPD for DUP. 1. Failed RPD for DUP: The relative percent difference (172275028 and 120119654) for K-40 and Pb-212 did not meet the duplication criteria.

1.K-40 and Pb-212 are naturally occurring nuclides.

All other nuclides meet within the duplication criteria.

Reporting results.Additional Comments Additional comments were not required for this sample set.Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance.

Cesium- 134 172875021 1201196540 Method/Analysis Information 21 Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 172875001 172875002 172875003 172875004 172875005 172875006 172875007 172875008 172875009 172875010 172875011 172875012 172875013 172875014 172875015 172875016 172875017 172875018 172875019 172875020 1201196545 1201196546 1201196547 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574338 574174 Client ID 9520-0003-002F 9520-0003-003F 9520-0003-019F 9520-0003-004F 9520-0003-004FS 9520-0003-018F 9520-0003-01IF 9520-0003-016F 9520-0003-017F 9520-0003-012F 9520-0003-01OF 9520-0003-009F 9520-0003-015F 9520-0003-006F 9520-0003-005F 9520-0003-008F 9520-0003-020F 9520-0003-007F 9520-0003-013F 9520-0003-014F Method Blank (MB)172875001 (9520-0003-002F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).22 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172875001 (9520-0003-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 371401 was generated due to Failed RPD for DUP. 1. Failed RPD for DUP: The Ac-228 relative percent difference (172875001 and 1201196546) did not meet within the duplication criteria.

1.Ac-228 is a naturally occurring nuclide. All other nuclides meet the duplication criteria.

Reporting results.Additional Comments Additional comments were not required for this sample set.Qualifier information 23 Qualifier UI UI Reason Data rejected due to high peak-width.

Data rejected due to interference.

Data rejected due to low abundance.

UI Analyte Cesium- 134 Europium-155 Manganese-54 Cesium- 134 Europium-154 Sample 172875002 172875009 172875006 172875011 172875014 172875003 172875004 172875006 172875007 172875009 172875014 172875018 172875008 Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr9O, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 574221 574186 574174 Sample ID 172875001 172875011 1201196231 1201196232 1201196233 1201196234 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172875011(9520-0003-01 OF) Sample Duplicate (DUP)172875011(9520-0003-01OF)

Matrix Spike (MS)Laboratory Control Sample (LCS)24 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172875011 (9520-0003-01OF).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.25 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: Analytical Batch Number: Sample ID 172875001 172875011 1201195648 1201195649 1201195650 1201195651 DOE EML HASL-300, Tc-02-RC Modified 574010 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172879001 (9805-0000-008F)

Sample Duplicate (DUP)172879001 (9805-0000-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172879001 (9805-0000-008F).

QC Information All of the QC samples met the required acceptance limits.26 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 172875001 (9520-0003-002F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe- 1, Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 574527 574186 574174 Sample ID 172875001 172875011 1201196975 1201196976 1201196977 1201196978 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172875001 (9520-0003-002F)

Sample Duplicate (DUP)172875001 (9520-0003-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)27 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172875001 (9520-0003-002F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.28 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni- 1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 574530 574186 574174 Sample ID 172875001 172875011 1201196983 1201196984 1201196985 1201196986 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172879007(9805-0000-013F)

Sample Duplicate (DUP)172879007(9805-0000-013F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.29 Designated QC The following sample was used for QC: 172879007 (9805-0000-013F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 172875001 172875011 1201206809 1201206810 1201206811 1201206812 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 579033 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172879001 (9805-0000-008F)

Sample Duplicate (DUP)172879001(9805-0000-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)30 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172879001 (9805-0000-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.31 Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 172875001 172875011 1201195657 1201195658 1201195659 1201195660 Liquid Scint C14, Solid AII,FSS EPA EERF C-0l Modified 574014 Client ID 9520-0003-002F 9520-0003-01 OF Method Blank (MB)172875001 (9520-0003-002F)

Sample Duplicate (DUP)172875001(9520-0003-002F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 172875001 (9520-0003-002F).

QC Information All of the QC samples met the required acceptance limits.32 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Oualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

33 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 368031 Revision No.: 1 COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 05-OCT-06 Radiochemistry Specifications Process Instrument Type: Test / Method: Matrix Type: Client Code: GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID: Sample Numbers: 574336 See Below Potentially affected work order(s)(SDG):

172275(MSR#06-1282),172873(MSR#06-1313),172875(MSR#06-1312),172879(MSR#06-1311)

Application Issues: Failed RPD for DUP Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. Failed RPD for DUP: The relative percent difference (172275028
1. K-40 and Pb-212 are naturally occurring nuclides.

All other nuclides and 120119654) for K-40 and Pb-212 did not meet the duplication meet within the duplication criteria.

Reporting results.criteria.Originator's Name: Jimmy Hartley Quality Review: Data Validator/Group Leader: Lesley Anderson 09-OCT-06 05-OCT-06 Director: Page 1 34 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 371401 Revision No.: 1 COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 13-OCT-06 Radiochemistry SOP Process Instrument Type: Test / Method: Matrix Type: Client Code: GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID: Sample Numbers: 574338 172875001, 1201196546 Potentially affected work order(s)(SDG):

172875(MSR#06-1312)

Application Issues: Failed RPD for DUP Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. Failed RPD for DUP: The Ac-228 relative percent difference
1. Ac-228 is a naturally occurring nuclide. All other nuclides meet the (172875001 and 1201196546) did not meet within the duplication criteria, duplication criteria.

Reporting results.Originator's Name: Jimmy Hartley Quality Review: Data Validator/Group Leader: Heather Anderson 18-OCT-06 13-OCT-06 Director: Page 1 35 SAMPLE DATA

SUMMARY

36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1312 GEL Work Order: 172875 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: 9520-0003-002F Proiect: YANKO 1204 Sample ID: 172875001 ClientID:

YANK001 Matrix: TS Vol. Recv.: Collect Date: 25-SEP-06 Receive Date: 29-SEP-06 Collector:

Client Moisture:

8.18%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0174 d Curium-242 U 0.0367 d Curium-243/244 U 0.0218 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0481 Plutonium-239/240 U -0.0518 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 3.31 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.439 Americium-241 U -0.0205 Bismuth-212 0.430 Bismuth-214 0.551 +Cesium- 134 U 0.0212 Cesium-137 U 0.0306 +Cobalt-60 U 0.00322 -+Europium-152 U -0.0167 -+Europium-154 U -0.0206 -+Europium-155 U 0.0578 4 Lead-212 0.727 4 Lead-214 0.591 4 Manganese-54 U 0.022 4 Niobium-94 U 0.012 +Potassium-40 12.0 Radium-226 0.551 +Silver-108m U 0.00876 +Thallium-208 0.211 +Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00739 +Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.567-/-0.0837-/-0.0719+/-0.146 0.0808 0.00 0.114+/-0.0837+/-0.0721+/-0.147 0.254 0.0995 0.321 0.219 0.230 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.111 0.0678 +/-0.111-/-0.0384 0.0732 +/-0.0387+/-8.25 6.78 +/-8.26 14.2 pCi/g+/-0.182+/-0.107+/-0.282 1-0.0772+/-0.024 1-0.0362-/-0.0221-/-0.0527-/-0.0573-/-0.0545/-0.0603/-0.0923-/-0.0369-/-0.0191+/-0.921/-0.0772-/-0.0166/-0.0451 0.065 0.0854 0.134 0.0304 0.0218 0.0184 0.019 0.0438 0.0463 0.053 0.0242 0.0296 0.0177 0.0172 0.172 0.0304 0.0154 0.0165+/-0.182+/-0.107+/-0.282+/-0.0772+/-0.024+/-0.0362+/-0.0221+/-0.0527+/-0.0573+/-0.0545+/-0.0603+/-0.0923+/-0.0369+/-0.0191+/-0.921+/-0.0772+/-0.0166+/-0.0451 0.140 0.177 0.287 0.0652 0.0467 0.0394 0.0421 0.0926 0.104 0.110 0.0507 0.0627 0.0381 0.0367 0.385 0.0652 0.0326 0.0354 0.0254 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g JASI 10/12/06 1617 578044 1 JAS1 10/12/06 1204 578046 3 JASI 10/10/06 1615 574558 5 MJHI 10/11/06 1645 574338 7 KSDI 10/04/06 2326 574221 8 MXPI 10/16/06 1818 579033 9/-0.0146 0.0117 +/-0.0146+/-7.07 5.89 +/-7.07 12.7 pCi/g 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9520-0003-002F 172875001 Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AlI,FSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd-0.018 +/-0.0708 0.0602 +/-0.0708 0.126 1.82 +/-42.6 30.8 +/-42.6 64.5 pCi/g pCi/g pCi/g pCi/g AXD2 10/03/06 1902 574014 12 MXPI 10/04/06 1949 574527 13 MXPI 10/06/06 0928 574530 14 KXRI 10/10/06 1023 574010 16 3.44 +/-4.86 3.93 +/-4.86 8.24 0.173 +/-0.229 0.188 +/-0.229 0.387 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 DOE EML HASL-300, Pu-1i -RC Modified 5 DOE EML HASL-300, Pu-I I-RC Modified 6 DOE EML HASL-300, Pu-l1-RC Modified 7 EML HASL 300, 4.5.2.3 8 EPA 905.0 Modified 9 EPA 906.0 Modified 10 EPA 906.0 Modified II EPA 906.0 Modified 12 EPA EERF C-01 Modified 13 DOE RESL Fe-1, Modified 14 DOE RESL Ni-l, Modified 15 DOE RESL Ni-l, Modified 16 DOE EML HASL-300, Tc-02-RC Modified 17 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9520-0003-002F 172875001 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Alphaspec Am24 1, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 83 91 88 84 55 84 72 (151/6-125%)

(15°,-125%)

(25%-125%)

(25%-/125%)

(15%-125%)

(25%-/125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-003F 172875002 TS 25-SEP-06 29-SEP-06 Client 3.97%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.658 +/-0.138 Americium-241 U 0.102 +/-0.0924 Bismuth-212 0.582 +/-0.240 Bismuth-214 0.526 +/-0.0735 Cesium-134 UI 0.00 +/-0.0364 Cesium-137 0.0554 +/-0.0272 Cobalt-60 U 0.0142 +/-0.0225 Europium-152 U -0.0164 +/-0.0522 Europium-154 U 0.0532 +/-0.0619 Europium-155 U 0.0222 +/-0.0524 Lead-212 0.650 +/-0.0589 Lead-214 0.512 +/-0.0832 Manganese-54 U 0.00982 +/-0.0177 Niobium-94 U 0.012 +/-0.0178 Potassium-40 9.49 +/-0.807 Radium-226 0.526 +/-0.0735 Silver-108m U -0.00728 +/-0.0165 Thallium-208 0.158 +/-0.037 0.0527 0.0679 0.117 0.0291 0.0161 0.0174 0.0204 0.0393 0.0575 0.0482 0.0255 0.0302 0.0159 0.0162 0.150 0.0291 0.0138 0.0172+/-0.138+/-0.0924+/-0.240+/-0.0735+/-0.0364+/-0.0272+/-0.0225+/-0.0522+/-0.0619+/-0.0524+/-0.0589+/-0.0832+/-0.0177+/-0.0178+/-0.807+/-0.0735+/-0.0165+/-0.037 0.114 0.140 0.251 0.062 0.0348 0.0371 0.0443 0.0828 0.124 0.0997 0.0529 0.0634 0.0342 0.0344 0.334 0.062 0.0293 0.0364 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1645 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-003F Proiect: YANKO1204 Sample ID: 172875002 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-019F 172875003 TS 25-SEP-06 29-SEP-06 Client 6.79%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.702 +/-0.154 Americium-241 U -0.0596 +/-0.106 Bismuth-212 0.408 +/-0.217 Bismuth-214 0.570 +/-0.0854 Cesium-134 UI 0.00 +/-0.033 Cesium- 137 0.178 +/-0.0403 Cobalt-60 U 0.00463 +/-0.018 Europium-152 U 0.00359 +/-0.047 Europium-154 U 0.0118 +/-0.0585 Europium-155 U 0.0378 +/-0.0497 Lead-212 0.777 +/-0.0554 Lead-214 0.606 +/-0.0779 Manganese-54 U 0.0026 +/-0.0211 Niobium-94 U 0.000837 +/-0.0158 Potassium-40 11.3 +/-0.782 Radium-226 0.570 +/-0.0854 Silver-108m U -0.00243 +/-0.016 Thallium-208 0.239 +/-0.0397 0.0521 0.0828 0.116 0.0275 0.0181 0.017 0.0153 0.0382 0.0496 0.0443 0.0248 0.0278 0.0152 0.0131 0.125 0.0275 0.0136 0.0133+/-0.154+/-0.106+/-0.217+/-0.0854+/-0.033+/-0.0403+/-0.018+/-0.047+/-0.0585+/-0.0497+/-0.0554+/-0.0779+/-0.0211+/-0.0158+/-0.782+/-0.0854+/-0.016+/-0.0397 0.111 0.171 0.245 0.0578 0.0383 0.0357 0.0334 0.0797 0.107 0.0912 0.0511 0.058 0.0322 0.0278 0.277 0.0578 0.0285 0.0282 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1646 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-019F Project: YANK0 1204 Sample ID: 172875003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-004F 172875004 TS 25-SEP-06 29-SEP-06 Client 5.58%Proeect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.760 +/-0.142 Americium-241 U 0.0261 +/-0.0287 Bismuth-212 0.448 +/-0.358 Bismuth-214 0.577 +/-0.0856 Cesium-134 UI 0.00 +/-0.0273 Cesium-137 U 0.0245 +/-0.0272 Cobalt-60 U 0.0133 +/-0.0192 Europium-152 U 0.0284 +/-0.0494 Europium-154 U -0.0176 +/-0.058 Europium-155 U 0.0249 +/-0.0459 Lead-212 0.681 +/-0.0575 Lead-214 0.558 +/-0.0905 Manganese-54 U -0.0119 +/-0.0198 Niobium-94 U 0.0174 +/-0.0214 Potassium-40 10.7 +/-0.907 Radium-226 0.577 +/-0.0856 Silver-108m U 0.00125 +/-0.0154 Thallium-208 0.255 +/-0.0413 0.0565 0.0258 0.130 0.0322 0.023 0.0195 0.0179 0.0419 0.0479 0.0435 0.0246 0.0304 0.0157 0.0176 0.157 0.0322 0.0139 0.0183+/-0.142+/-0.0287+/-0.358+/-0.0856+/-0.0273+/-0.0272+/-0.0192+/-0.0494+/-0.058+/-0.0459+/-0.0575+/-0.0905+/-0.0198+/-0.0214+/-0.907+/-0.0856+/-0.0154+/-0.0413 0.123 0.053 0.280 0.0686 0.0489 0.0414 0.0397 0.0883 0.106 0.0897 0.0512 0.0641 0.0341 0.0375 0.353 0.0686 0.0296 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/11/06 1646 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-004F Proiect: YANK01204 Sample ID: 172875004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-004FS 172875005 TS 25-SEP-06 29-SEP-06 Client 5.6%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.687 +/-0.159 Americium-241 U -0.0904 +/-0.0881 Bismuth-212 U 0.157 +/-0.144 Bismuth-214 0.531 +/-0.0763 Cesium-134 U 0.0129 +/-0.0235 Cesium-137 0.0433 +/-0.0207 Cobalt-60 U 0.0132 +/-0.0212 Europium-152 U -0.0203 +/-0.0465 Europium-154 U -0.0241 +/-0.0612 Europium-155 U 0.0814 +/-0.0498 Lead-212 0.654 +/-0.0542 Lead-214 0.570 +/-0.0845 Manganese-54 U -0.00247 +/-0.0192 Niobium-94 U 0.0235 +/-0.0249 Potassium-40 10.6 +/-0.830 Radium-226 0.531 +/-0.0763 Silver-108m U -0.00796 +/-0.0151 Thallium-208 0.215 +/-0.0382 0.0507 0.0664 0.130 0.0302 0.0187 0.0153 0.0194 0.0386 0.0501 0.0499 0.0238 0.0313 0.0161 0.0176 0.152 0.0302 0.0131 0.0157+/-0.159+/-0.0881+/-0.144+/-0.0763+/-0.0235+/-0.0207+/-0.0212+/-0.0465+/-0.0612+/-0.0498+/-0.0542+/-0.0845+/-0.0192+/-0.0249+/-0.830+/-0.0763+/-0.0151+/-0.0382 0.111 0.138 0.277 0.0644 0.0402 0.0329 0.0423 0.0815 0.110 0.103 0.0497 0.0658 0.0347 0.0374 0.340 0.0644 0.028 0.0335 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1646 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-004FS Project: YANK01204 Sample ID: 172875005 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-018F 172875006 TS 25-SEP-06 29-SEP-06 Client 4.05%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.722 +/-0.153 Americium-241 U -0.0346 +/-0.0861 Bismuth-212 0.326 +/-0.213 Bismuth-214 0.641 +/-0.0863 Cesium-134 UI 0.00 +/-0.0253 Cesium-137 U 0.0326 +/-0.0204 Cobalt-60 U 0.000629 +/-0.0188 Europium-152 U -0.0152 +/-0.0456 Europium-154 U -0.0641 +/-0.0591 Europium-155 U 0.0737 +/-0.0544 Lead-212 0.799 +/-0.0578 Lead-214 0.701 +/-0.0849 Manganese-54 UI 0.00 +/-0.032 Niobium-94 U 0.00886 +/-0.0178 Potassium-40 11.5 +/-0.844 Radium-226 0.641 +/-0.0863 Silver-108m U-0.000698

+/-0.0168 Thallium-208 0.244 +/-0.0429 0.0484 0.072 0.126 0.0283 0.0196 0.0175 0.0159 0.0404 0.0434 0.0524 0.0228 0.0258 0.0159 0.0157 0.151 0.0283 0.0148 0.0155+/-0.153+/-0.0861+/-0.213+/-0.0863+/-0.0253+/-0.0204+/-0.0188+/-0.0456+/-0.0591+/-0.0544+/-0.0578+/-0.0849+/-0.032+/-0.0178+/-0.844+/-0.0863+/-0.0168+/-0.0429 0.106 0.149 0.269 0.0604 0.0417 0.0372 0.0351 0.085 0.096 0.108 0.0476 0.0547 0.0341 0.0333 0.335 0.0604 0.0313 0.033 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1647 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-018F Proiect: YANK01204 Sample ID: 172875006 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-01F 172875007 TS 25-SEP-06 29-SEP-06 Client 6.05%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.789 +/-0.189 Americium-241 U -0.0329 +/-0.0774 Bismuth-212 0.761 +/-0.316 Bismuth-214 0.551 +/-0.108 Cesium- 134 UI 0.00 +/-0.0429 Cesium-137 0.0577 +/-0.049 Cobalt-60 U 0.0151 +/-0.0225 Europium-152 U 0.0262 +/-0.0605 Europium-154 U 0.0687 +/-0.0733 Europium-155 U 0.0147 +/-0.0603 Lead-212 0.758 +/-0.0859 Lead-214 0.637 +/-0.104 Manganese-54 U 0.0408 +/-0.0421 Niobium-94 U 0.00463 +/-0.021 Potassium-40 11.1 +/-1.12 Radium-226 0.551 +/-0.108 Silver-108m U -0.0137 +/-0.0204 Thallium-208 0.214 +/-0.0417 0.0531 0.0668 0.131 0.038 0.0238 0.0197 0.0206 0.0537 0.0676 0.0524 0.0323 0.0364 0.0204 0.0179 0.152 0.038 0.0167 0.0179+/-0.189+/-0.0774+/-0.316+/-0.108+/-0.0429+/-0.049+/-0.0225+/-0.0605+/-0.0733+/-0.0603+/-0.0859+/-0.104+/-0.0421+/-0.021+/-1.12+/-0.108+/-0.0204+/-0.0417 0.117 0.137 0.282 0.0803 0.0507 0.042 0.0452 0.112 0.146 0.108 0.0669 0.0763 0.0436 0.0381 0.345 0.0803 0.0354 0.0381 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1647 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-01F Project: YANK01204 Sample ID: 172875007 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-016F 172875008 TS 25-SEP-06 29-SEP-06 Client 8%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.677 +/-0.137 Americium-241 U -0.192 +/-0.0975 Bismuth-212 U 0.252 +/-0.310 Bismuth-214 0.595 +/-0.085 Cesium-134 U 0.0322 +/-0.0386 Cesium-137 U 0.0325 +/-0.0285 Cobalt-60 U 0.00631 +/-0.0213 Europium-152 U -0.0166 +/-0.0515 Europium-154 UI 0.00 +/-0.0623 Europium-155 U -0.00423 +/-0.0543 Lead-212 0.755 +/-0.0564 Lead-214 0.610 +/-0.0848 Manganese-54 U 0.00966 +/-0.0222 Niobium-94 U -0.00145 +/-0.0175 Potassium-40 10.5 +/-0.762 Radium-226 0.595 +/-0.085 Silver-108m U 0.00607 +/-0.0185 Thallium-208 0.258 +/-0.0424 0.0644 0.0761 0.134 0.0289 0.0206 0.0175 0.0183 0.0442 0.0497 0.0509 0.0274 0.0318 0.0175 0.0153 0.126 0.0289 0.0144 0.0173+/-0.137+/-0.0975+/-0.310+/-0.085+/-0.0386+/-0.0285+/-0.0213+/-0.0515+/-0.0623+/-0.0543+/-0.0564+/-0.0848+/-0.0222+/-0.0175+/-0.762+/-0.085+/-0.0185+/-0.0424 0.137 0.157 0.284 0.0614 0.0437 0.037 0.0399 0.0925 0.108 0.105 0.0568 0.0666 0.0372 0.0325 0.285 0.0614 0.0303 0.0366 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/11/06 1647 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-016F Project: YANK01204 Sample ID: 172875008 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-017F 172875009 TS 25-SEP-06 29-SEP-06 Client 9.26%Proiect: Client ID: Vol. Recv.: YANK01204 YANK00l Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.739 +/-0.175 Americium-241 U 0.0177 +/-0.0394 Bismuth-212 U 0.251 +/-0.306 Bismuth-214 0.536 +/-0.106 Cesium-134 UI 0.00 +/-0.0307 Cesium-137 U 0.0437 +/-0.0381 Cobalt-60 U 0.0114 +/-0.0252 Europium-152 U 0.0107 +/-0.0555 Europium-154 U 0.00269 +/-0.0741 Europium-155 UL 0.00 +/-0.0718 Lead-212 0.663 +/-0.065 Lead-214 0.654 +/-0.0852 Manganese-54 U 0.0141 +/-0.0265 Niobium-94 U -0.00139 +/-0.0225 Potassium-40 10.1 +/-0.799 Radium-226 0.536 +/-0.106 Silver-108m U-0.000385

+/-0.0185 Thallium-208 0.225 +/-0.0482 0.0725 0.0287 0.155 0.0395 0.0258 0.022 0.0222 0.0489 0.0631 0.0437 0.0358 0.0338 0.0233 0.0194 0.198 0.0395 0.0168 0.0199+/-0.175+/-0.0394+/-0.306+/-0.106+/-0.0307+/-0.0381+/-0.0252+/-0.0555+/-0.0741+/-0.0718+/-0.065+/-0.0852+/-0.0265+/-0.0225+/-0.799+/-0.106+/-0.0185+/-0.0482 0.155 0.059 0.328 0.083 0.0544 0.0464 0.0481 0.102 0.136 0.0903 0.0737 0.0708 0.0491 0.0409 0.432 0.083 0.0354 0.042 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1648 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/29/06 1610 574174 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-017F Project: YANK01204 Sample ID: 172875009 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-012F 172875010 TS 25-SEP-06 29-SEP-06 Client 5.86%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.740 Americium-241 U 0.000773 -Bismuth-212 0.509 Bismuth-214 0.544 -Cesium-134 U 0.00754 -Cesium-137 U 0.0275 -Cobalt-60 U 0.00671 -Europium-152 U -0.0293 -Europium-154 U 0.00364 -Europium-155 U 0.0648 -Lead-212 0.729 -+/-0. 151+l-0.0261I

+/-0.216+/-0.0716+/-0.0217+I-0.0288+I-0.0233+I-0.0427+I-0.0666+I-0.0376+/-0.0518+I-0.0879+I-0.0234+/-0.0 179+/-0.770+/-0.07 16+/-0.0147+/-0.0423 0.0586 0.0217 0.126 0.0282 0.0189 0.0179 0.0178 0.0348 0.0566 0.038 0.022 0.029 0.0157 0.0156 0.126 0.0282 0.0136 0.0162+/-0.151+/-0.0261+/-0.216+/-0.0716+/-0.0217+/-0.0288+/-0.0233+/-0.0427+/-0.0666+/-0.0376+/-0.0518+/-0.0879+/-0.0234+/-0.0179+/-0.770+/-0.0716+/-0.0147+/-0.0423 0.126 0.0447 0.268 0.0601 0.0404 0.0381 0.039 0.0736 0.123 0.0785 0.0458 0.0608 0.0339 0.0332 0.287 0.0601 0.0287 0.0344 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/11/06 1648 574338 1 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.598 U 0.0257 U 0.00374 11.1 0.544 U 0.00507 0.240 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-012F Proiect: YANK01204 Sample ID: 172875010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: 9520-0003-01017 Project: YANK01204 Sample ID: 172875011 Client ID: YANK001 Matrix: TS Vol. Recv.: Collect Date: 25-SEP-06 Receive Date: 29-SEP-06 Collector:

Client Moisture:

4.97%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00369 Curium-242 U -0.0119 Curium-243/244 U 0.0874+/-0.0863+/-0.0936+/-0.153 0.0743 0.0845 0.0992+/-0.0863+/-0.0936+/-0.153 Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0198 Plutonium-239/240 U 0.0259 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 3.96 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.796 Americium-241 U -0.0141 Bismuth-212 0.627 Bismuth-214 0.508 Cesium-134 U 0.0257 Cesium-137 0.0459 Cobalt-60 U 0.0248 Europium-152 U 0.0668 Europium-154 U -0.00831 Europium-155 U 0.0314 Lead-212 0.764 Lead-214 0.637 Manganese-54 UI 0.00 Niobium-94 U 0.00106 Potassium-40 11.5 Radium-226 0.508 Silver-108m U-0.000216 Thallium-208 0.262 Rad Gas Flow Proportional Counting+/-0.0982 0.0919 +/-0.0982+/-0.113 0.0831 +/-0.114+/-7.88 6.44 +/-7.90+/-0.164 F/-0.0609+/-0.202 F/-0.0846 F/-0.0248+/-0.0227 F/-0.0231 F/-0.0362 F/-0.0527 F/-0.0467 F/-0.0753+/-0.075+/-0.0188+/-0.018+/-0.962 F/-0.0846+/-0.0149 F/-0.0434 0.0461 0.046 0.108 0.0247 0.0181 0.0155 0.0154 0.0361 0.044 0.0406 0.0227 0.026 0.0127 0.0131 0.119 0.0247 0.0127 0.0131+/-0.164+/-0.0609+/-0.202+/-0.0846+/-0.0248+/-0.0227+/-0.0231+/-0.0362+/-0.0527+/-0.0467+/-0.0753+/-0.075+/-0.0188+/-0.018+/-0.962+/-0.0846+/-0.0149+/-0.0434 0.224 0.250 0.273 0.268 0.250 13.5 0.0976 0.0939 0.225 0.0516 0.0378 0.0324 0.0328 0.0748 0.0937 0.0829 0.0466 0.0539 0.0269 0.0273 0.258 0.0516 0.0265 0.0275 0.0262 14.5 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g JAS1 10/12/06 1617 578044 1 JAS1 10/12/06 1204 578046 3 JASI 10/10/06 1631 574558 5 MJH1 10/11/062007 574338 7 KSD1 10/04/06 2326 574221 8 MXP1 10/16/06 1834 579033 9 GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.0251 +/-0.0121 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.65 +/-8.18 0.0121 +/-0.0121 6.76 +/-8.18 59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9520-0003-01OF 172875011 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AlI,FSS Carbon- 14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.00604 +/-0.0774 0.0647 +/-0.0774 0.135 pCi/g 1.20 +/-37.8 26.9 +/-37.8 56.1 pCi/g 10.4 +/-6.43 4.97 +/-6.44 10.4 pCi/g AXD2 10/03/06 2004 574014 12 MXP1 10/04/06 2005 574527 13 MXP1 10/06/06 1000 574530 14 KXR1 10/09/06 0806 574010 16 0.164 +/-0.288 0.237 +/-0.288 0.489 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1610 574174 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 DOE EML HASL-300, Pu- I1-RC Modified 5 DOE EML HASL-300, Pu- I1-RC Modified 6 DOE EML HASL-300, Pu-11 -RC Modified 7 EML HASL 300,4.5.2.3 8 EPA 905.0 Modified 9 EPA 906.0 Modified 10 EPA 906.0 Modified 11 EPA 906.0 Modified 12 EPA EERF C-01 Modified 13 DOE RESL Fe-1, Modified 14 DOE RESL Ni-1, Modified 15 DOE RESL Ni-1, Modified 16 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 94 (15%-125%)

60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-OIOF Project: YANK01204 Sample ID: 172875011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Plutonium-242 Alphaspec Pu, Solid-ALL FSS 84 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 92 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 88 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 68 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 77 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-009F 172875012 TS 25-SEP-06 29-SEP-06 Client 9.79%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.682 U 0.0296 0.708 0.569 U 0.0335 0.171 U -0.00558 U 0.00569 U 0.0155 U 0.0428 0.737 0.663 U 0.000384 U -0.0228 11.4 0.569 U 0.0142 0.322+/-0.226+/-0.0355+/-0.366+/-0.109+/-0.0365+/-0.067+/-0.033+/-0.0618+/-0.0747+/-0.0819+/-0.065+/-0.102+/-0.0284+/-0.026+/-1.04+/-0.109+/-0.0232+/-0.0507 0.0827 0.0337 0.176 0.0469 0.0277 0.0246 0.0272 0.0555 0.0649 0.0512 0.0298 0.0379 0.0236 0.0202 0.184 0.0469 0.0211 0.021+/-0.226+/-0.0355+/-0.366+/-0.109+/-0.0365+/-0.067+/-0.033+/-0.0618+/-0.0747+/-0.0819+/-0.065+/-0.102+/-0.0284+/-0.026+/-1.04+/-0.109+/-0.0232+/-0.0507 0.179 0.0693 0.379 0.0996 0.0594 0.0525 0.0598 0.117 0.144 0.106 0.0622 0.080 0.0509 0.0435 0.422 0.0996 0.0447 0.0452 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1650 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-009F Proiect: YANK01204 Sample ID: 172875012 Client ID: YANK00l Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-015F 172875013 TS 25-SEP-06 29-SEP-06 Client 10.1%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 0.803 U 0.0138 0.567 0.568 U 0.0221 0.155 U 0.0122 U 0.0151 U -0.00537 U 0.0396 0.782 0.607 U -0.00484 U -0.0114 11.4 0.568 U-0.000441 0.221+/-0.120+/-0.0213+/-0.237+/-0.0676+/-0.0181+/-0.0259+/-0.0155+/-0.0381+/-0.0436+/-0.0347+/-0.0461+/-0.0666+/-0.0164+/-0.0138+/-0.620+/-0.0676+/-0.013+/-0.0355 0.0446 0.0183 0.101 0.0245 0.0164 0.0114 0.0141 0.0349 0.0368 0.0325 0.0183 0.024 0.0135 0.0112 0.0944 0.0245 0.0115 0.0133+/-0.120+/-0.0213+/-0.237+/-0.0676+/-0.0181+/-0.0259+/-0.0155+/-0.0381+/-0.0436+/-0.0347+/-0.0461+/-0.0666+/-0.0164+/-0.0138+/-0.620+/-0.0676+/-0.013+/-0.0355 0.0948 0.0374 0.212 0.0513 0.0344 0.0242 0.0303 0.0722 0.0793 0.0665 0.0377 0.0497 0.0284 0.0235 0.210 0.0513 0.0239 0.0278 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/062007 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-015F Project: YANK01204 Sample ID: 172875013 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-006F 172875014 TS 25-SEP-06 29-SEP-06 Client 9.44%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.773 U 0.0294 0.382 0.585 UI 0.00 0.0653 U 0.0194 U -0.00837 U -0.0331 U 0.0736 0.786 0.743 UL 0.00 U 0.0114 12.9 0.585 U 0.00368 0.275+/-0.163+/-0.0601+/-0.210+/-0.0732+/-0.0197+/-0.0253+/-0.0173+/-0.0405+/-0.0503+/-0.0494+/-0.0521+/-0.0707+/-0.0165+/-0.0137+/-0.672+/-0.0732+/-0.0133+/-0.0396 0.0497 0.0568 0.100 0.0243 0.0161 0.0139 0.0138 0.0357 0.0395 0.0468 0.0206 0.0256 0.0122 0.0127 0.111 0.0243 0.0118 0.0133+/-0.163+/-0.0601+/-0.210+/-0.0732+/-0.0197+/-0.0253+/-0.0173+/-0.0405+/-0.0503+/-0.0494+/-0.0521+/-0.0707+/-0.0165+/-0.0137+/-0.672+/-0.0732+/-0.0133+/-0.0396 0.105 0.117 0.212 0.0512 0.0339 0.0293 0.0297 0.0743 0.0847 0.0961 0.0427 0.0533 0.026 0.0266 0.244 0.0512 0.0247 0.0279 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1650 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-006F Project: YANK01204 Sample ID: 172875014 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-005F 172875015 TS 25-SEP-06 29-SEP-06 Client 14.5%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.682 +/-0.198 Americium-241 U -0.0659 +/-0.106 Bismuth-212 0.740 +/-0.403 Bismuth-214 0.519 +/-0.110 Cesium-134 U 0.0364 +/-0.0299 Cesium-137 0.107 +/-0.0466 Cobalt-60 U 0.0178 +/-0.0265 Europium-152 U 0.000438 +/-0.0751 Europium-154 U -0.00468 +/-0.0814 Europium-155 U 0.122 +/-0.0704 Lead-212 0.806 +/-0.0974 Lead-214 0.594 +/-0.112 Manganese-54 U 0.0278 +/-0.0284 Niobium-94 U -0.00909 +/-0.0236 Potassium-40 12.7 +/-1.21 Radium-226 0.519 +/-0.110 Silver-108m U -0.00725 +/-0.0215 Thallium-208 0.218 +/-0.0516 0.0662 0.0789 0.146 0.0415 0.0271 0.0199 0.0239 0.059 0.0677 0.064 0.030 0.0412 0.0234 0.0189 0.182 0.0415 0.018 0.0222+/-0.198+/-0.106+/-0.403+/-0.110+/-0.0299+/-0.0466+/-0.0265+/-0.0751+/-0.0814+/-0.0704+/-0.0974+/-0.112+/-0.0284+/-0.0236+/-1.21+/-0.110+/-0.0215+/-0.0516 0.132 0.158 0.291 0.083 0.0541 0.0397 0.0477 0.118 0.135 0.128 0.060 0.0824 0.0468 0.0378 0.365 0.083 0.0359 0.0444 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1705 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.corn Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-005F Proiect: YANK01204 Sample ID: 172875015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-008F 172875016 TS 25-SEP-06 29-SEP-06 Client 9.55%Project: YANK01204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.679 +/-0.204 Americium-241 U 0.0491 +/-0.0357 Bismuth-212 U 0.331 +/-0.302 Bismuth-214 0.576 +/-0.119 Cesium-134 U 0.0397 +/-0.0364 Cesium- 137 0.199 +/-0.0558 Cobalt-60 U 0.00569 +/-0.0275 Europium-152 U -0.0747 +/-0.076 Europium-154 U 0.0702 +/-0.0924 Europium-155 U 0.0435 +/-0.0691 Lead-212 0.620 +/-0.0827 Lead-214 0.461 +/-0.102 Manganese-54 U 0.0163 +/-0.0231 Niobium-94 U -0.0111 +/-0.024 Potassium-40 11.0 +/-1.02 Radium-226 0.576 +/-0.119 Silver-108m U -0.00143 +/-0.0206 Thallium-208 0.173 +/-0.0516 0.0817 0.0303 0.177 0.0424 0.0315 0.0273 0.0237 0.0495 0.0842 0.046 0.0281 0.0386 0.0214 0.0203 0.187 0.0424 0.0178 0.0194+/-0.204+/-0.0357+/-0.302+/-0.119+/-0.0364+/-0.0558+/-0.0275+/-0.076+/-0.0924+/-0.0691+/-0.0827+/-0.102+/-0.0231+/-0.024+/-1.02+/-0.119+/-0.0206+/-0.0516 0.163 0.0606 0.354 0.0847 0.063 0.0546 0.0474 0.0989 0.168 0.092 0.0561 0.0771 0.0429 0.0406 0.373 0.0847 0.0356 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/11/06 1706 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-008F Project: YANK01204 Sample ID: 172875016 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-020F 172875017 TS 25-SEP-06 29-SEP-06 Client 6.44%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.699 +/-0.208 Americium-241 U -0.00562 +/-0.0339 Bismuth-212 0.731 +/-0.365 Bismuth-214 0.485 +/-0.120 Cesium- 134 U 0.0406 +/-0.0463 Cesium- 137 0.205 +/-0.053 Cobalt-60 U 0.0379 +/-0.0291 Europium-152 U -0.0152 +/-0.0658 Europium-154 U -0.0312 +/-0.0821 Europium-155 U 0.0626 +/-0.0752 Lead-212 0.658 +/-0.0731 Lead-214 0.588 +/-0.109 Manganese-54 U -0.0308 +/-0.0278 Niobium-94 U 0.0278 +/-0.0253 Potassium-40 10.3 +/-0.932 Radium-226 0.485 +/-0.120 Silver-108m U 0.0131 +/-0.0214 Thallium-208 0.260 +/-0.0574 0.0771 0.0299 0.168 0.039 0.0297 0.027 0.0275 0.0553 0.0665 0.0515 0.0398 0.0416 0.021 0.0231 0.238 0.039 0.0198 0.0227+/-0.208+/-0.0339+/-0.365+/-0.120+/-0.0463+/-0.053+/-0.0291+/-0.0658+/-0.0821+/-0.0752+/-0.0731+/-0.109+/-0.0278+/-0.0253+/-0.932+/-0.120+/-0.0214+/-0.0574 0.165 0.0616 0.357 0.0827 0.0626 0.0566 0.0592 0.116 0.144 0.106 0.0818 0.0868 0.0449 0.0487 0.516 0.0827 0.0416 0.0479 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/12/06 1202 574338 I The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 72 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-020F Proeect: YANK01204 Sample ID: 172875017 ClientID:

YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.73 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-007F 172875018 TS 25-SEP-06 29-SEP-06 Client 16.5%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.904 +/-0.146 Americium-241 U 0.0203 +/-0.067 Bismuth-212 0.477 +/-0.206 Bismuth-214 0.629 +/-0.0815 Cesium- 134 UI 0.00 +/-0.0315 Cesium-137 0.137 +/-0.0417 Cobalt-60 U -0.00429 +/-0.0182 Europium-152 U -0.00502 +/-0.0449 Europium-154 U 0.021 +/-0.0489 Europium-155 U 0.0831 +/-0.0561 Lead-212 0.870 +/-0.0594 Lead-214 0.715 +/-0.0849 Manganese-54 U 0.0225 +/-0.0191 Niobium-94 U 0.017 +/-0.0171 Potassium-40 15.1 +/-0.827 Radium-226 0.629 +/-0.0815 Silver-108m U -0.0051 +/-0.015 Thallium-208 0.317 +/-0.0425 0.0498 0.061 0.105 0.0277 0.018 0.0155 0.0146 0.039 0.0422 0.0516 0.0233 0.0279 0.0159 0.0157 0.141 0.0277 0.0126 0.0134+/-0.146+/-0.067+/-0.206+/-0.0815+/-0.0315+/-0.0417+/-0.0182+/-0.0449+/-0.0489+/-0.0561+/-0.0594+/-0.0849+/-0.0191+/-0.0171+/-0.827+/-0.0815+/-0.015+/-0.0425 0.106 0.126 0.223 0.0583 0.0379 0.0327 0.0316 0.0813 0.091 0.106 0.0482 0.0582 0.0335 0.0329 0.305 0.0583 0.0265 0.0283 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/12/06 1202 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 74 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9520-0003-007F 172875018 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.75 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analvsis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-013F 172875019 TS 26-SEP-06 29-SEP-06 Client 11%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.603 +/-0.141 Americium-241 U 0.00973 +/-0.023 Bismuth-212 0.345 +/-0.216 Bismuth-214 0.469 +/-0.0805 Cesium-134 U 0.0325 +/-0.0348 Cesium-137 U 0.028 +/-0.0243 Cobalt-60 U -0.00893 +/-0.0187 Europium-152 U -0.0115 +/-0.040 Europium-154 U 0.000379 +/-0.0568 Europium-155 U 0.0425 +/-0.0645 Lead-212 0.513 +/-0.0494 Lead-214 0.558 +/-0.0756 Manganese-54 U -0.0059 +/-0.0174 Niobium-94 U -0.0164 +/-0.0166 Potassium-40 8.50 +/-0.766 Radium-226 0.469 +/-0.0805 Silver-108m U 0.000482 +/-0.0143 Thallium-208 0.167 +/-0.0346 0.0499 0.0228 0.132 0.0281 0.019 0.0149 0.015 0.0363 0.049 0.038 0.0229 0.0241 0.0142 0.0131 0.173 0.0281 0.013 0.0174+/-0.141+/-0.023+/-0.216+/-0.0805+/-0.0348+/-0.0243+/-0.0187+/-0.040+/-0.0568+/-0.0645+/-0.0494+/-0.0756+/-0.0174+/-0.0166+/-0.766+/-0.0805+/-0.0143+/-0.0346 0.109 0.047 0.282 0.0602 0.0407 0.0321 0.0336 0.0768 0.108 0.0786 0.0477 0.0513 0.031 0.0282 0.383 0.0602 0.0276 0.0369 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/12/06 1328 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 76 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-013F Project: YANK01204 Sample ID: 172875019 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.0I Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.77 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-014F 172875020 TS 26-SEP-06 29-SEP-06 Client 6.86%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 B ismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.596 U 0.034 0.405 0.431 U 0.0279 0.114 U 0.0197 U 0.0246 U 0.00746 U 0.0342 0.627 0.492 U -0.00486 U 0.00327 11.8 0.431 U -0.0108 0.238+/-0.195+/-0.0893+/-0.255+/-0.097+/-0.0243+/-0.0421+/-0.020+/-0.0634+/-0.0719+/-0.0586+/-0.0674+/-0.0753+/-0.0229+/-0.0183+/-0.935+1-0.097+/-0.0204+/-0.0588 0.0675 0.079 0.120 0.0344 0.023 0.0184 0.0195 0.0555 0.0625 0.0557 0.0311 0.0345 0.019 0.0161 0.164 0.0344 0.0163 0.0185+/-0.195+/-0.0893+/-0.255+/-0.097+/-0.0243+/-0.0421+/-0.020+/-0.0634+/-0.0719+/-0.0586+/-0.0674+/-0.0753+/-0.0229+/-0.0183+/-0.935+/-0.097+/-0.0204+/-0.0588 0.147 0.164 0.263 0.0737 0.0494 0.0397 0.0437 0.117 0.138 0.115 0.0647 0.073 0.0412 0.0348 0.374 0.0737 0.0348 0.0398 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/12/06 1329 574338 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 78 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-014F Project: YANK01204 Sample ID: 172875020 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.79 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Report Date: October 18, 2006 Project: Soils PO# 002332 Client Sample ID: 9520-0003-014FS Project: YANK01204 Sample ID: 172875021 Client ID: YANK001 Matrix: TS Vol. Recv.: Collect Date: 26-SEP-06 Receive Date: 29-SEP-06 Collector:

Client Moisture:

6.55%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.933 +/-0.230 Americium-241 U 0.025 +/-0.0421 Bismuth-212 0.829 +/-0.494 Bismuth-214 0.707 +/-0.137 Cesium-134 UI 0.00 +/-0.0481 Cesium-137 U 0.0127 +/-0.032 Cobalt-60 U 0.00321 +/-0.0343 Europium-152 U 0.012 +/-0.0899 Europium-154 U -0.063 +/-0.112 Europium-155 U 0.0403 +/-0.0642 Lead-212 0.898 +/-0.104 Lead-214 0.633 +/-0.120 Manganese-54 U -0.00428 +/-0.0286 Niobium-94 U -0.011 +/-0.0275 Potassium-40 13.9 +/-1.30 Radium-226 0.707 +/-0.137 Silver-108m U -0.0106 +/-0.0242 Thallium-208 0.306 +/-0.0668 0.092 0.0338 0.180 0.0411 0.0323 0.0287 0.0289 0.0601 0.0872 0.0571 0.0308 0.0432 0.0243 0.0232 0.257 0.0411 0.0201 0.0228+/-0.230+/-0.0421+/-0.494+/-0.137+/-0.0481+/-0.032+/-0.0343+/-0.0899+/-0.112+/-0.0642+/-0.104+/-0.120+/-0.0286+/-6.0275+/-1.30+/-0.137+/-0.0242+/-0.0668 0.184 0.0676 0.359 0.0821 0.0646 0.0574 0.0578 0.120 0.174 0.114 0.0617 0.0863 0.0486 0.0463 0.514 0.0821 0.0402 0.0456 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/02/06 1518 574336 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 80 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-014FS Project: YANK01204 Sample ID: 172875021 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.81 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-001F 172875022 TS 26-SEP-06 29-SEP-06 Client 12.5%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.592 +/-0.107 Americium-241 U 0.0138 +/-0.089 Bismuth-212 0.386 +/-0.261 Bismuth-214 0.542 +/-0.0677 Cesium-134 U 0.0314 +/-0.0202 Cesium-137 0.158 +/-0.0254 Cobalt-60 0.214 +/-0.0344 Europium-152 U -0.00552 +/-0.0376 Europium-154 U 0.0287 +/-0.0474 Europium-155 U 0.0327 +/-0.0528 Lead-212 0.707 +/-0.0477 Lead-214 0.639 +/-0.0656 Manganese-54 U -0.00202 +/-0.0163 Niobium-94 U -0.00393 +/-0.013 Potassium-40 11.6 +/-0.692 Radium-226 0.542 +/-0.0677 Silver-108m U -0.00514 +/-0.0155 Thallium-208 0.201 +/-0.0344 0.0424 0.0786 0.0877 0.025 0.0176 0.014 0.0128 0.0337 0.0431 0.0439 0.0202 0.0264 0.0122 0.0113 0.123 0.025 0.0117 0.0128+/-0.107+/-0.089+/-0.261+/-0.0677+/-0.0202+/-0.0254+/-0.0344+1-0.0376+/-0.0474+/-0.0528+/-0.0477+/-0.0656+/-0.0163+/-0.013+/-0.692+/-0.0677+/-0.0155+/-0.0344 0.0905 0.162 0.187 0.0524 0.0369 0.0294 0.0278 0.0704 0.092 0.0908 0.0419 0.055 0.0259 0.0239 0.268 0.0524 0.0245 0.0268 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/03/06 0520 574336 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 09/29/06 1615 574180 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 82 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of -Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9520-0003-00IF 172875022 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.83 QUALITY CONTROL DATA 84 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: October 18, 2006 Page 1 of 12 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

172875 Parmname NOM Sample Oual OC Units RPD %REC% Range Anist Date Time Rad Alpha Spec Batch 574558 QC1201197067 172879001 DUP Plutonium-241 QC1201197069 LCS Plutonium-241 QC1201197066 MB Plutonium-241 QC1201197068 172879001 MS Plutonium-241 U 2.68 Uncert: +/-7.20 TPU: +/-7.20 U 3.67+/-9.16+/-9.17 pCi/g 0 (0% -100%) JASI 123 Uncert: TPU: Uncert: TPU: 144 U Uncert: TPU: 107+/-12.0+/-18.6 U 3.56+/-7.43+/-7.44 pCi/g pCi/g pCi/g 87 (75%-125%)

89 (75%-125%)

10/10/06 17:36 10/10/06 18:09 10/10/06 17:20 10/10/06 17:53 2.68+/-7.20+/-7.20 127+/-16.3+/-23.9 Batch 578044 QC1201204516 Americium-241 Curium-242 Curium-243/244 QC1201204518 Americium-241 Curium-242 Curium-243/244 QC1201204515 Americium-241 172879001 DUP U -0.0902 Uncert: +/-0.120 TPU: +/-0.121 U -0.143 Uncert: +/-0.0702 TPU: +/-0.0724 U -0.0746 Uncert: +/-0.172 TPU: +/-0.173 LCS 12.3 Uncert: TPU: Uncert: TPU: 14.8 Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0331+/-0.101+/-0.101 U -0.00812+/-0.0159+/-0.0159 U -0.163+/-0.178+/-0.179 13.0+/- 1.24+/-2.01 U 0.00+/-0.0599+/-0.0599 16.6+/-1.40+/-2.46 U 0.00339+/-0.118+/-0.118 U 0.00+/-0.0711+/-0.0711 pCi/g 93 pCi/g 179 pCi/g 74 pCi/g (0% -100%) JASI (0%- 100%)(0% -100%)106 (75%-125%)

10/12/06 16:17 pCi/g pCi/g pCi/g pCi/g 112 (75%-125%)

MB Curium-242 85 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 2 of 12 REC% Ranee AnIst Date Time Parmname NOM Samnle Oual OC Units RPD%Rad Alpha Spec Batch 57804-4 Curium-243/244 Uncert: TPU: U -0.164+/-0.0739+/-0.0767 QC1201204517 172879001 MS Americium-241 Curium-242 Curium-243/244 Batch 578046 QC1201204520 172879001 DUP Plutonium-238 Plutonium-239/240 QC1201204522 LCS Plutonium-238 Plutonium-239/240 13.5 U -0.0902 Uncert: +/-0.120 TPU: +/-0.121 U -0.143 Uncert: +/-0.0702 TPU: +/-0.0724 16.3 U -0.0746 Uncert: +/-0.172 TPU: +/-0.173 U -0.0161 Uncert: +/-0.127 TPU: +/-0.127 U 0.047 Uncert: +/-0.135 TPU: +/-0.135 Uncert: TPU: 11.4 Uncert: TPU: U 12.8+/-1.31+/-2.05-0.0368+/-0.0361+/-0.0364 17.7+/-1.55+/-2.68 pCi/g pCi/g pCi/g pCi/g 109 (75%-125%)

95 (75%-125%)

U 0.0223+/-0.150+/-0.150 U 0.00278+/-0.107+/-0.107 U 0.0311+/-0.128+/-0.128 10.3+/-1.03+/-1.46 U -0.0384+/-0.0799+/-0.080 U -0.0317+/-0.0719+/-0.0719 pCi/g 1240 pCi/g 178 pCi/g pCi/g (0% -100%) JASI 10/12/06 12:04 (0%- 100%)(75%- 125%)90 (75%-125%)

QC1201204519 MB Plutonium-238 Plutoniumr-239/240 QC1201204521 172879001 MS Plutonium-238 Plutonium-239/240 Rad Gamma Spec Batch 574336 QC1201196540 172275028 DUP Actinium-228 Uncert: TPU: Uncert: TPU: pCi/g pCilg pCilg pCigg U -0.0161 Uncert: +/-0.127 TPU: +/-0.127 12.5 U 0.047 Uncert: +/-0.135 TPU: +/-0.135 U-0.0462+/-0.0811+/-0.0813 11.6+/-1.21+/-1.71 (75%-125%)

93 (75%-125%)

0.575 Uncert: +/-0.137 TPU: +/-0.137 0.630+/-0.144+/-0.144 pCi/g 9 (0% -100%) MJHI 10/03/06 06:14 86 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 3 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574336 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 U -0.000377 Uncert: +/-0.0553 TPU: +/-0.0553 0.487 Uncert: +/-0.229 TPU: +/-0.229 0.606 Uncert: +/-0.0922 TPU: +/-0.0922 u 0.027 Uncert: +/-0.0188 TPU: +/-0.0188 3.50 Uncert: +/-0.317 TPU: +/-0.317 0.089 Uncert: +/-0.0294 TPU: +/-0.0294 u -0.0197 Uncert: +/-0.049 TPU: +/-0.049 u -0.0211 Uncert: +/-0.0462 TPU: +/-0.0462 u 0.0382 Uncert: +/-0.0686 TPU: +/-0.0686 0.583 Uncert: +/-0.066 TPU: +/-0.066 0.695 Uncert: +/-0.107 TPU: +/-0.107 U 0.0169 Uncert: +/-0.0161 TPU: +/-0.0161 U -0.00138 Uncert: +/-0.0123 TPU: +/-0.0123 9.02 Uncert: +/-0.922 TPU: +/-0.922 0.606 Uncert: +/-0.0922 TPU: +/-0.0922 U -0.0159 Uncert: +/-0.0205 TPU: +/-0.0205 U -0.000296+/-0.0229+/-0.0229 0.548+/-0.181+/-0.181 0.535+/-0.0773+/-0.0773 UI 0.00+/-0.0445+/-0.0445 U 0.0209+/-0.0312+/-0.0312 U 0.00347+/-0.0186+/-0.0186 U -0.00689+/-0.0417+/-0.0417 U 0.081+/-0.109+/-0.109 U 0.0429+/-0.047+/-0.047 0.738+/-0.0492+/-0.0492 0.589+/-0.0747+/-0.0747 U 0.0287+/-0.0174+/-0.0174 U 0.0073+/-0.0179+/-0.0179 12.2+/-0.876+/-0.876 0.535+/-0.0773+/-0.0773 U 0.0066+/-0.014+/-0.014 pCi/g 24 pCi/g 12 pCi/g 12 pCi/g 72 pCi/g 198*pCi/g 185 pCi/g 96 pCi/g 341 pCi/g 12 pCi/g 23*pCi/g 17 pCi/g 52 pCi/g 293 pCi/g 30*pCi/g 12 pCi/g 483 (0%- 100%)(0% -100%)(0% -100%)(0%- 100%)(0%-20%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0%- 100%)(0% -100%)(0% -20%)(0% -100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m 87 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 4 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574336 Thallium-208 QCI201196541 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 0.186 Uncert: +/-0.0436 TPU: +/-0.0436 0.254+/-0.0405+/-0.0405 pCi/g 31 (0%- 100%)LCS Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.56 Uncert: TPU: 14.3 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.000391+/-0.575+/-0.575 25.5+/-2.52+/-2.52 U -0.528+/-0.989+/-0.989 U 0.0129+/-0.236+/-0.236 U -0.0169+/-0.145+/-0.145 10.1+/-0.768+/-0.768 14.6+/-1.01+/-1.01 U -0.00861+/-0.305+/-0.305 U 0.382+/-0.275+/-0.275 U -0.0392+/-0.332+/-0.332 U -0.11+/-0.163+/-0.163 U 0.185+/-0.234+/-0.234 U -0.00693+/-0.128+/-0.128 U -0.0972+/-0.118+/-0.118 U 0.676+/-1.06 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 10/03/06 07:26 109 (75%-125%)

106 (75%-125%)

102 (75%-125%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Uncert: 88 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 5 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574336 TPU: Radium-226 Silver- 108m Thallium-208 QC1201196539 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.06 U 0.0129+/-0.236+/-0.236 U -0.0142+/-0.119+/-0.119 U 0.100+/-0.123+/-0.123 U 0.0435+/-0.091+/-0.091 U -0.0204+/-0.055+/-0.055 U -0.00499+/-0.109+/-0.109 U 0.0577+/-0.031+/-0.031 U 0.00937+/-0.0158+/-0.0158 U -0.00291+/-0.0137+/-0.0137 U 0.000491+/-0.0155+/-0.0155 U -0.00472+/-0.0376+/-0.0376 U 0.00671+/-0.0299+/-0.0299 U 0.0139+/-0.0336+/-0.0336 U 0.0167+/-0.0287+/-0.0287 U 0.0536+/-0.0433+/-0.0433 U -0.00217 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 10/03/06 06:13 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 89 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 6 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574336 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Batch 574338 QCI1201196546 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 172875001 DUP 0.439 Uncert: +/-0.182 TPU: +/-0.182 u -0.0205 Uncert: +/-0.107 TPU: +/-0.107 0.430 Uncert: +/-0.282 TPU: +/-0.282 0.551 Uncert: +/-0.0772 TPU: +/-0.0772 U 0.0212 Uncert: +/-0.024 TPU: +/-0.024 U 0.0306 Uncert: +/-0.0362 TPU: +/-0.0362 U 0.00322 Uncert: +/-0.0221 TPU: +/-0.0221 U -0.0167 Uncert: +/-0.0527 TPU: +/-0.0527 U -0.0206 Uncert: +/-0.0573 TPU: +/-0.0573 U 0.0578 Uncert: +/-0.0545+/-0.0116+/-0.0116 U 0.0106+/-0.0136+/-0.0136 U 0.0767+/-0.436+/-0.436 U 0.0577+/-0.031+/-0.031 U 0.0117+/-0.0122+/-0.0122 U 0.0111+/-0.0142+/-0.0142 0.852+/-0.172+/-0.172 U -0.11+/-0.0944+/-0.0944 0.541+/-0.235+/-0.235 0.480+/-0.109+/-0.109 U 0.0282+/-0.0241+/-0.0241 0.0415+/-0.0205+/-0.0205 U 0.0195+/-0.0229+/-0.0229 U -0.0493+/-0.0516+/-0.0516 U 0.0241+/-0.0648+/-0.0648 U 0.0573+/-0.0581 pCilg pCi/g pci/g pci/g pci/g pCi/g 64 pCi/g 137 pCi/g 23 pCi/g 14 pCi/g 28 pCi/g 30 pCi/g 143 pCi/g 99 pCi/g 2540 pCi/g 1 (0% -100%) MJHI 10/12/06 13:31 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -100%)(0% -100%)(0% -100%)(0%- 100%)90 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 7 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574338 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC1201196547 Actinium-228 Americium-241 TPU: +/-0.0545 0.727 Uncert: +/-0.0603 TPU: +/-0.0603 0.591 Uncert: +/-0.0923 TPU: +/-0.0923 U 0.022 Uncert: +/-0.0369 TPU: +/-0.0369 u 0.012 Uncert: +/-0.0191 TPU: +/-0.0191 12.0 Uncert: +/-0.921 TPU: +/-0.921 0.551 Uncert: +/-0.0772 TPU: +/-0.0772 U 0.00876 Uncert: +/-0.0166 TPU: +/-0.0166 0.211 Uncert: +/-0.0451 TPU: +/-0.0451+/-0.0581 0.666+/-0.0618+/-0.0618 0.606+/-0.0817+/-0.0817 U -0.00234+/-0.0224+/-0.0224 U 9.630E-05+/-0.0186+/-0.0186 11.8+/-0.937+/-0.937 0.480+/-0.109+/-0.109 U 0.00663+/-0.0254+/-0.0254 0.225+/-0.0394+/-0.0394 U 0.0546+/-0.413+/-0.413 26.1+/-1.51+1-1.51 U -0.00138+/-0.683+/-0.683 U 0.168+/-0.165+/-0.165 U 0.0431+/-0.104+/-0.104 10.7+/-0.394+/-0.394 15.7+/-0.536+/-0.536 U 0.00889 pCi/g 9 pCi/g 2 pCi/g 248 pCi/g 197 pCi/g 2 pCi/g 14 pCi/g 28 pCi/g .7 (0% -20%)(0% -20%)(0% -100%)(0%- 100%)(0% -20%)(0%- 100%)(0% -100%)(0%- 100%)LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.56 Uncert: TPU: 14.3 Uncert: TPU: pCi/g pCi/g pCi/g pCi/g pci/g pci/g 111 (75%-125%)

10/12/06 13:31 112 (75%-125%)

109 (75%-125%)

Cobalt-60 Europium-152 91 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 8 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574338 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC 1201196545 Actinium-228 Americium-241 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.210+/-0.210 U 0.0265+/-0.208+/-0.208 U -0.103+/-0.255+/-0.255 U 0.0523+/-0.133+/-0.133 U 0.0178+/-0.164+/-0.164 U -0.0545+/-0.0953+/-0.0953 U -0.00841+/-0.0849+/-0.0849 U -0.238+/-0.763+/-0.763 U 0.168+/-0.165+/-0.165 U 0.0372+/-0.0841+/-0.0841 U 0.0104+/-0.0874+/-0.0874 U 0.00146+/-0.0566+/-0.0566 U -0.0603+/-0.0328+/-0.0328 U -0.0159+/-0.0908+/-0.0908 U 0.0195+/-0.0237+/-0.0237 U -0.00834+/-0.0106+/-0.0106 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

MB 10/12/06 13:30 Bismuth-212 Bismuth-214 Cesium- 134 92 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 9 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 574338 Cesium- 137 U 0.00238 pCi/g Uncert: +/-0.0107 TPU: +/-0.0107 Cobalt-60 U 0.00992 pCi/g Uncert: +/-0.0105 TPU: +/-0.0105 Europium-152 U -0.00483 pCi/g Uncert: +/-0.0303 TPU: +/-0.0303 Europium-154 U -0.0113 pCi/g Uncert: +/-0.0308 TPU: +/-0.0308 Europium-155 U -0.00238 pCi/g Uncert: +/-0.0277 TPU: +/-0.0277 Lead-212 U 0.025 pCi/g Uncert: +/-0.0186 TPU: +/-0.0186 Lead-214 U 0.000345 pCi/g Uncert: +/-0.0225 TPU: +/-0.0225 Manganese-54 U 0.00744 pCi/g Uncert: +/-0.0114 TPU: +/-0.0114 Niobium-94 U 0.00162 pCi/g Uncert: +/-0.0116 TPU: +/-0.0116 Potassium-40 U 0.160 pCi/g Uncert: +/-0.129 TPU: +/-0.129 Radium-226 U 0.0195 pCi/g Uncert: +/-0.0237 TPU: +/-0.0237 Silyer- 108m U -0.00271 pCi/g Uncert: +/-0.0105 TPU: +/-0.0105 Thallium-208 U 0.00702 pCi/g Uncert: +/-0.0114 TPU: +/-0.0114 Rad Gas Flow Batch 574221 QC1201196232 172875011 DUP Strontium-90 U -0.0251 U 0.0221 pCi/g 0 (0% -100%) KSDI 10/04/06 23:26 Uncert: +/-0.0121

+/-0.0157 TPU: +/-0.0121

+/-0.0157 QCI201196234 LCS Strontium-90 1.74 1.83 pCi/g 105 (75%-125%)

10/04/06 23:26 Uncert: +/-0.121 93 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 10 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gas Flow Batch 574221 TPU:+/-0.133 QCI1201196231 MB Strontium-90 QC1201196233 172875011 MS Strontium-90 Rad Liquid Scintillation Batch 574010 QC1201195649 172879001 DUP Technetium-99 QC1201195651 LCS Technetium-99 QC1201195648 MB Technetium-99 QC1201195650 172879001 MS Technetium-99 Uncert: TPU: U 0.0207+/-0.0142+/-0.0142 pCi/g pCi/g 10/04/06 23:26 10/04/06 23:26 3.72 U Uncert: TPU:-0.0251+/-0.0121+/-0.0121 3.25+/-0.225+/-0.244 87 (75%-125%)

-0.0681 Uncert: +/-0.263 TPU: +/-0.263 13.0 Uncert: TPU: U 0.099+/-0.279+/-0.279 12.2+/-0.488+/-0.562 U 0.0765+/-0.239+/-0.239 pCi/g 0 (0% -100%) KXR1 pCi/g pCi/g pCi/g 94 (75%-125%)

10/09/06 09:12 10/09/06 09:44 10/09/06 08:55 10/09/06 09:28 Uncert: TPU: 13.0 U Uncert: TPU:-0.0681+/-0.263+/-0.263 Batch 574014 QC1201195658 172875001 DUP Carbon- 14 QC1201195660 LCS Carbon- 14 QC1201195657 MB Carbon- 14 QC1201195659 172875001 MS Carbon- 14 U -0.018 Uncert: +/-0.0708 TPU: +/-0.0708 U 12.3+/-0.562+/-0.629-0.0777+/-0.0723+/-0.0723 7.75+/-0.496+/-0.510 95 (75%-125%)

pCi/g 0 (0% -100%) AXD2 6.74 Uncert: TPU: Uncert: TPU: 7.18 U Uncert: TPU: U -0.0593+/-0.067+/-0.067 pCi/g pCi/g pCi/g 115 (75%-125%)

10/04/06 00:15 10/04/06 01:35 10/03/06 23:12 10/04/06 01:17-0.018+/-0.0708+/-0.0708 B atch 574527 7.99+/-0.510+/-0.525-0.127+/-39.5+/-39.5 111 (75%-125%)

QC1201196976 172875001 DUP Iron-55 U 1.82 Uncert: +/-42.6 TPU: +/-42.6 U pCi/g 0 (0% -100%) \IXPi 10/04/06 21:11 94 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

172875 Parmname Rad Liquid Scintillation Batch 574527 QC1201196978 LCS Iron-55 QC1201196975 MB Iron-55 QC1201196977 172875001 MS Iron-55 Batch 574530 QC1201196984 172879007 DUP Nickel-63 QC1201196986 LCS Nickel-63 QC1201196983 MB Nickel-63 QC1201196985 172879007 MS Nickel-63 Batch 579033 QC1201206810 172879001 DUP Tritium QC 1201206812 LCS Tritium QC1201206809 MB Tritium QC1201.206811 172879001 MS Tritium QC Summary Sample Qual QC Page 11 of 12 Units RPD% REC% Range Anist NOM Date Time 631 Uncert: TPU: Uncert: TPU: 663 U 1.82 Uncert: +/-42.6 TPU: +/-42.6 U 9.42 Uncert: +/-6.03 TPU: +/-6.04 500 Uncert: TPU: Uncert: TPU: 556 U 9.42 Uncert: +/-6.03 TPU: +/-6.04 U -3.35 Uncert: +/-6.99 TPU: +/-6.99 67.6 Uncert: TPU: Uncert: TPU: 58.5 U -3.35 Uncert: +/-6.99 TPU: +/-6.99 629+/-58.3+/-76.2 U 20.6+/-32.0+/-32.0 636+/-59.5+/-74.9 10.2+/-6.13+/-6.14 469+/-15.9+/-21.7 U 6.26+/-7.08+/-7.08 528+/-17.4+/-24.7 U 0.248+/-6.67+/-6.67 72.3+/-12.3+/-12.3 U 1.63+/-8.10+/-8.10 51.6+/-10.2+/-10.3 pCi/g pCi/g pCi/g 100 (75%-125%)

96 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 8 (0% -100%) qIXP1 94 (75%-125%)

10/04/06 21:43 10/04/06 20:54 10/04/06 21:27 10/06/06 12:07 10/06/06 13:10 10/06/06 11:35 10/06/06 12:38 10/16/06 19:40 10/16/06 20:12 10/16/06 19:23 10/16/06 19:56 95 (75%-125%)

0 (0% -100%) \4XP1 107 (75%-125%)

88 (75%-125%)

95 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

172875 Page 12 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time e Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.96 General Narrative 1 General Narrative for Connecticut Yankee Atomic Power Co.Work Order: 173429 SDG: MSR#06-1334 October 12, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on October 06, 2006 and October 09, 2006 for analysis.

Shipping container temperatures were checked, documented, and within specifications.

The samples were delivered with proper chain of custody documentation and signatures.

All sample containers arrived without any visible signs of tampering or breakage.

The incorrect MSR was listed on COC 2006-00560, please see attached email for clarification.

Sample Identification The laboratory received the following samples: Laboratory Identification 173429001 173429002 173429003 173429004 173429005 173429006 173429007 173429008 173429009 173429010 173429011 173429012 173429013 173429014 173429015 Sample Description 9520-0003-021F 9520-0003-022F 9520-0003-023F 9520-0003-024F 9520-0003-025F 9520-0003-026F 9520-0003-027F 9520-0003-028F 9520-0003-029F 9520-0003-030F 9520-0003-031F 9520-0003-035F 9520-0003-036F 9520-0003-037F 9520-0003-038F Items of Note There are no items to note.2.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.Analytical Request Fifteen soil samples were analyzed for FSSGAM.Data Package The enclosed data package contains the following sections:

General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions:

Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

CheryJojnes Project Manager 3 List of current GEL Certifications as of 12 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FI/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C 1641 4 Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 No. 2006-00560 Project Name: Haddam Neck Decommissioning Contact Name & Phone: Jack McCarthy 860-267-3924 Analyses Requested Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones 0 Priority:

[] 30 D. [] 14 D. Z 7 D. D] 3 D.Sample Designation Date Time Media Code Sample Type Code Container Size-&Type Code 9520-0003-021F 9/26/06 1341 TS G BP X 9520-0003-022F 9/26/06 1345 TS G BP X 9520-0003-023F 9/26/06 1348 TS G BP X 9520-0003-024F 9/26/06 1353 TS G BP X 9520-0003-025F 9/26/06 1400 TS G BP X 9520-0003-026F 9/26/06 1410 TS G BP X 9520-0003-027F 9/26/06 1411 TS G BP X 9520-0003-028F 9/26/06 1421 TS G BP X 9520-0003-029F 9/26/06 1423 TS G BP X 9520-0003-030F 9/26/06 1432 TS G BP X 9520-0003-03 IF 9/26/06 1434 TS G BP X NOTES: PO #: 002332 5-ýW? 66-04-0(MSR #: 06-135 SSWP# NA Z LTP QA El Radwaste QA M] Non QA_ýVt~ ZQ -1) Reli=nq d Date/Time

2) Re eived By Date/Time 3) lmquished By Date/Time
4) R eived By late/Time Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form N.20-09 Connecticut Yankee Atomic Power Company No. 2006-00595 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lalb Use .Contact Name & Phone: c.. ." ...ts... .. .Jack McCarthy 860-267-3924 , , ', ...Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <. ý ..843 556 8171. Attn. Cheryl Jones Priority:

J30OD.D 14D.Z7D.LI3D.

Samnple Size-- -- :, ,,,:: ..:!Sample Designation Date Time Media Type &Type Comment Preservation Lab Sample ID Code Code Code ::'!,"I:z

": :; " :: 9520-0003-035F 9/29/06 0724 TS G BP X -----9520-0003-036F 9/29/06 0727 TS G BP X -' .9520-0003-037F 9/29/06 0735 TS G BP X 9520-0003-038F 9/29/06 0740 TS G BP X -"-NOTES: PO #: 002332 MSR #: 06-13 ý Y SSWP# NA Z LTP QA El Radwaste QA E] Non QA Samples Shipped Via: Z Fed Ex F-1 ups LI Hand E] Other Bill of Lading #lIittemal r~ainer T'emp.: TLEDeg.~Custo~dySealed?.

Cusf d'y Seal Intat 1)R R 'shed y Date/Time

2) Received By Date/Time 3) ed By Date/Time
4) Received By Date/Time RE: Please confirm MSR designation

Subject:

RE: Please confirm MSR designation From: "Arthur L. Hammnond" <Hammond@CYAPCO.com>

Date: Tue, 10 Oct 2006 15:22:42 -0400 To: "Cheryl Jones" <cj@gel.com>

CC: "John McCarthy" <McCarthy@

CYA.PCO.com>

Cheryl, All information, per your c-mail, is correct.Sample 9506-0-6C is for CHALL.MSR#06 1334: includes COCs 2006-00595, 00560, 00561, and 00603 MSRf06-1335:

sample 9506-0-6C on CDC 2006 0059!Thank you, Arthur... Original Message-----

From: Cheryl Jones [mailto:cj@gel.coml Sent: Tuesday, October 10, 2006 3:07 PM To: Arthur L. Hammond Cc: John McCarthy; Amanda Rasco

Subject:

Please confirm MSR designation Arthur.Please confirm the following MSR "es hiqnatjon for samples we roccived 10/6 and 10/9: MSR*06.-1334; 9520 series on COCs 2006-00595, 00560, 003561, 00603 MSR406-1335:

only sample 9506-0-6C on CCC 2006-00597 Please also cunfirm that sample 9506.0-6C is for CHALL, as the X was not on the COC tader that request coliumn.Thanks, Cheryl Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LAO 2040 Savage Road Charleston, SC (USA) 29407 Direct: 843.769.7383 Main: 843.556.8171 x 4243 Fax: 243.766.1178 E mail: -. cor Web: ,..,, " .co _The information contained in this message is confidential and is intended only for the use of the individual or firm of record. If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the paqes that follow. Please notify the sender irrnedi a tely by telephone or email if you have received this comMUnication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.I of I 8 10/10/2006 3:36 PM Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received:

..i SDG#: CUw D Work Order Number: _2-9. [_jL3"2 3t,-ý I? PLQA .Shipping Cdntainer 16_D.____

_ _ _hainofCustody#

-.-,_o_ _h_ _1. Custody Seals oif shipping container intact?- -Yes No 2. Custody Seals dated and signed? Ye", .No t '3. Chain-of-Custody record present? Yes o o ]-Ci*.4. Cooler temperature

-5. Vermiculite/packing materials is: , Wet [Dry..6:' Number of samples in shipping container:

'7 ; , 7. Sample holding times exceeded?

Yes [ ] No 8. Samples have.etape -hazard labels custody seals .appropriate sample labels 9. Samples are:'* in good condition

.leaking* ,_broken _have air bubbles 10. Were any anomalies identified in sample receipt? Yes []No Description of anomalies(include sample numbers): Sample Custodian/Laboratory:

Q.., 7 , Date: "" .Telephoned to: On By .'~~~_ _R .-- *' .* .. .--.- -

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OQI Figure 1. Sample Check-in List.Date/Time Received:

_ O/9ro '>3 ., SDG#: (go ,o,.Work Order Number: TI S3UA75 Shipping Ccfntainer ID:" 7"'fS 139t4 7 , c7 Chain of Custody # t0 04 .-? O 1. Custody Seals oxi shipping container intact? .Yest- No [ ]2. Custody Seals dated and. signed? Yes'M No [I]3. Chain-of-Custody record present? Yes No [ I 4. Cooler temperature

5. Vermiculite/packing materials is: Wet [ ] Dry [ ] AA-6,
  • Number of samples in shipping container:

1 " 7. Sample holding times exceeded?

Yes [ No 8. Samples have:_.. tape _ hazard labels* ,_custody seals " 9-_.appropriate sample labels 9. Samples are'--_in good condition leaking-broken -" have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No frJ 11. Description of anomalies (include sample numbers): Date {0/ S//2i Telephoned to: On By n.,- B Data Review Qualifier Definitions 11 Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound c Result is less than value reported* Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fa",f3) 766-1178 www.gel.com RADIOLOGICAL ANALYSIS 13 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 173429 Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 173429001 173429002 173429003 173429004 173429005 173429006 173429007 173429008 173429009 173429010 173429011 173429012 173429013 173429014 173429015 1201201884 1201201885 1201201886 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300,4.5.2.3 Dry Soil Prep 576803 576541 Client ID 9520-0003-021F 9520-0003-022F 9520-0003-023F 9520-0003-024F 9520-0003-025F 9520-0003-026F 9520-0003-027F 9520-0003-028F 9520-0003-029F 9520-0003-030F 9520-0003-031F 9520-0003-035F 9520-0003-036F 9520-0003-037F 9520-0003-038F Method Blank (MB)173429001(9520-0003-021F)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.Calibration Information:

Calibration Information 14 All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173429001 (9520-0003-021F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201201885 (9520-0003-021F) and 173429001 (9520-0003-021F) were recounted due to high relative percent difference/relative error ratio.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 15 Qualifier Reason Analyte Sample UI UI U'UI Data rejected due to high counting uncertainty.

Data rejected due to high peak-width.

Data rejected due to interference.

Data rejected due to low abundance.

Bismuth-212 Europium-155 Bismuth-214 Cesium- 134 173429009 173429015 173429010 173429011 173429009 173429001 173429002 173429007 173429011 173429013 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

YASX& 11Z6 Reviewer/Date:

16 SAMPLE DATA

SUMMARY

17 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1334 GEL Work Order: 173429 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: 9520-0003-021F Project: YANKO 1204 Sample ID: 173429001 ClientID:

YANK001 Matrix: TS Vol. Recv.: Collect Date: 26-SEP-06 Receive Date: 09-OCT-06 Collector:

Client Moisture:

9.25%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.669 U 0.0158 0.636 0.524 UI 0.00 0.0868 U 0.0098 U 0.016 U 0.0853 U 0.0625 0.665 0.609 U 0.0081 U 0.00664 11.2 0.524 U 0.0278 0.204+/-0.167+/-0.0993+/-0.338+/-0.103+/-0.0401+/-0.0408+/-0.0245+/-0.0604+/-0.0845+/-0.0553+/-0.0653+/-0.0981+/-0.0243+/-0.021+/-0.949+/-0.103+/-0.0208+/-0.053 0.0571 0.0804 0.132 0.0304 0.0269 0.0203 0.0221 0.0526 0.0639 0.0539 0.0283 0.0361 0.0213 0.0186 0.161 0.0304 0.0192 0.0176+/-0.167+/-0.0993+/-0.338+/-0.103+/-0.0401+/-0.0408+/-0.0245+/-0.0604+/-0.0845+/-0.0553+/-0.0653+/-0.0981+/-0.0243+/-0.021+/-0.949+/-0.103+/-0.0208+/-0.053 0.126 0.167 0.287 0.0657 0.0572 0.0434 0.0486 0.111 0.140 0.112 0.059 0.0762 0.0456 0.0397 0.367 0.0657 0.0406 0.0378 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/12/06 1015 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB 1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 19 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-0211F Project: YANK01204 Sample ID: 173429001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-022F 173429002 TS 26-SEP-06 09-OCT-06 Client 13.3%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.686 +/-0.175 Americium-241 U 0.0752 +/-0.139 Bismuth-212 U 0.275 +/-0.317 Bismuth-214 0.540 +/-0.0998 Cesium- 134 UI 0.00 +/-0.0316 Cesium-137 0.0752 +/-0.0338 Cobalt-60 U -0.00209 +/-0.0246 Europium-152 U -0.0237 +/-0.0607 Europium-154 U 0.0393 +/-0.0827 Europium-155 U -0.0528 +/-0.0639 Lead-212 0.752 +/-0.0629 Lead-214 0.549 +/-0.0959 Manganese-54 U 0.0209 +/-0.0216 Niobium-94 U -0.00183 +/-0.022 Potassium-40 11.6 +/-0.943 Radium-226 0.540 +/-0.0998 Silver-108m U -0.00164 +/-0.0207 Thallium-208 0.233 +/-0.0423 0.0602 0.0852 0.150 0.0334 0.024 0.020 0.020 0.050 0.0635 0.0552 0.0302 0.0408 0.020 0.0187 0.149 0.0334 0.0172 0.0188+/-0.175+/-0.139+/-0.317+/-0.0998+/-0.0316+/-0.0338+/-0.0246+/-0.0607+/-0.0827+/-0.0639+/-0.0629+/-0.0959+/-0.0216+/-0.022+/-0.943+/-0.0998+/-0.0207+/-0.0423 0.131 0.176 0.322 0.0713 0.051 0.0426 0.0442 0.105 0.138 0.114 0.0627 0.0853 0.0427 0.0398 0.340 0.0713 0.0363 0.040 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1409 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 10/09/06 1211 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 21 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-022F Proiect: YANK01204 Sample ID: 173429002 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-023F 173429003 TS 26-SEP-06 09-OCT-06 Client 4.43%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.950 +/-0.235 Americium-241 U -0.0193 +/-0.0372 Bismuth-212 0.533 +/-0.331 Bismuth-214 0.618 +/-0.119 Cesium- 134 U 0.0678 +/-0.0427 Cesium- 137 0.194 +/-0.0686 Cobalt-60 U 0.0118 +/-0.0335 Europium-152 U -0.00811 +/-0.0711 Europium-154 U -0.00214 +/-0.0919 Europium-155 U 0.0958 +/-0.0892 Lead-212 0.784 +/-0.0871 Lead-214 0.753 +/-0.110 Manganese-54 U 0.00839 +/-0.048 Niobium-94 U 0.012 +/-0.0263 Potassium-40 13.1 +/-1.03 Radium-226 0.618 +/-0.119 Silver-108m U 0.000128 +/-0.0231 Thallium-208 0.312 +/-0.0526 0.093 0.0318 0.200 0.0476 0.0329 0.0241 0.0289 0.0595 0.0769 0.0503 0.0466 0.0396 0.0257 0.023 0.168 0.0476 0.0205 0.0228+/-0.235+/-0.0372+/-0.331+/-0.119+/-0.0427+/-0.0686+/-0.0335+/-0.0711+/-0.0919+/-0.0892+/-0.0871+/-0.110+/-0.048+/-0.0263+/-1.03+/-0.119+/-0.0231+/-0.0526 0.198 0.0656 0.424 0.100 0.0692 0.0511 0.0623 0.124 0.166 0.104 0.0955 0.0832 0.0545 0.0486 0.381 0.100 0.0431 0.0482 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1409 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-023F Proiect: YANKO 1204 Sample ID: 173429003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-024F 173429004 TS 26-SEP-06 09-OCT-06 Client 10.5%Project: YANK01204 Client ID: YANK00I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.749 +/-0.186 Americium-241 U -0.002 +/-0.0554 Bismuth-212 0.413 +/-0.237 Bismuth-214 0.422 +/-0.0859 Cesium-134 U 0.0255 +/-0.0217 Cesium-137 0.0393 +/-0.0359 Cobalt-60 U 0.00672 +/-0.0174 Europium-152 U -0.0479 +/-0.0541 Europium-154 U -0.0375 +/-0.0602 Europium-155 U 0.0474 +/-0.0486 Lead-212 0.655 +/-0.0743 Lead-214 0.502 +/-0.0823 Manganese-54 U -0.00789 +/-0.0172 Niobium-94 U -0.00708 +/-0.0176 Potassium-40 12.2 +/-1.16 Radium-226 0.422 +/-0.0859 Silver-108m U 0.00837 +/-0.015 Thallium-208 0.185 +/-0.0363 0.0629 0.0477 0.109 0.0362 0.0202 0.0169 0.0157 0.0375 0.0479 0.0427 0.0205 0.0286 0.0138 0.0146 0.155 0.0362 0.0131 0.0168+/-0.186+/-0.0554+/-0.237+/-0.0859+/-0.0217+/-0.0359+/-0.0174+/-0.0541+/-0.0602+/-0.0486+/-0.0743+/-0.0823+/-0.0172+/-0.0176+/-1.16+/-0.0859+/-0.015+/-0.0363 0.135 0.0991 0.236 0.0763 0.0431 0.0361 0.0349 0.0794 0.106 0.0886 0.0431 0.0605 0.0301 0.0314 0.346 0.0763 0.028 0.0357 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/10/06 1410 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-024F Project: YANK01204 Sample ID: 173429004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected'U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-025F 173429005 TS 26-SEP-06 09-OCT-06 Client 8.44%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.706 +/-0.223 Americium-241 U 0.0159 +/-0.0368 Bismuth-212 0.523 +/-0.287 Bismuth-214 0.606 +/-0.114 Cesium-134 U 0.0408 +/-0.0408 Cesium-137 0.0568 +/-0.0427 Cobalt-60 U -0.0014 +/-0.0307 Europium-152 U 0.0749 +/-0.066 Europium-154 U 0.0757 +/-0.0972 Europium-155 U 0.0796 +/-0.0578 Lead-212 0.750 +/-0.0696 Lead-214 0.539 +/-0.102 Manganese-54 U 0.00981 +/-0.0321 Niobium-94 U -0.0335 +/-0.0284 Potassium-40 13.3 +/-1.12 Radium-226 0.606 +/-0.114 Silver-108m U 0.00702 +/-0.0236 Thallium-208 0.288 +/-0.0638 0.0754 0.0341 0.193 0.041 0.0331 0.0248 0.0256 0.0622 0.0888 0.0542 0.0321 0.0398 0.0273 0.0213 0.206 0.041 0.021 0.0219+/-0.223+/-0.0368+/-0.287+/-0.114+/-0.0408+/-0.0427+/-0.0307+/-0.066+/-0.0972+/-0.0578+/-0.0696+/-0.102+/-0.0321+/-0.0284+/-1.12+/-0.114+/-0.0236+/-0.0638 0.166 0.0703 0.413 0.0882 0.0704 0.0531 0.0569 0.131 0.193 0.112 0.0669 0.0841 0.0585 0.0458 0.469 0.0882 0.0445 0.047 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1410 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB 1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-025F Project: YANK01204 Sample ID: 173429005 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-026F 173429006 TS 26-SEP-06 09-OCT-06 Client 10.9%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 B ismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.764 U -0.0873 0.633 0.507 U 0.033 0.0654 U -0.008 U -0.0195 U -0.01 U 0.0341 0.735 0.523 U 0.0185 U 0.00577 13.5 0.507 U -0.0156 0.247+/-0.135+/-0.105+/-0.243+/-0.0821+/-0.0219+/-0.0289+/-0.0178+/-0.0439+/-0.0605+/-0.0556+/-0.0563+/-0.063+/-0.0178+/-0.0165+/-0.789+/-0.0821+/-0.0155+/-0.0363 0.0458 0.0843 0.108 0.0292 0.0188 0.014 0.0145 0.0377 0.0438 0.051 0.0256 0.0266 0.0163 0.0147 0.128 0.0292 0.0125 0.0147+/-0.135+/-0.105+/-0.243+/-0.0821+/-0.0219+/-0.0289+/-0.0178+/-0.0439+/-0.0605+/-0.0556+/-0.0563+/-0.063+/-0.0178+/-0.0165+/-0.789+/-0.0821+/-0.0155+/-0.0363 0.0985 0.175 0.230 0.0615 0.0396 0.0298 0.0317 0.079 0.0947 0.106 0.053 0.0557 0.0344 0.031 0.282 0.0615 0.0264 0.031 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/10/06 1411 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 10/09/06 1211 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-026F Proiect: YANK01204 Sample ID: 173429006 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-027F 173429007 TS 26-SEP-06 09-OCT-06 Client 12.4%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.732 +/-0.132 Americium-241 U -0.00442 +/-0.0642 Bismuth-212 0.476 +/-0.237 Bismuth-214 0.502 +/-0.0823 Cesium-134 UI 0.00 +/-0.026 Cesium-137 0.0772 +/-0.0253 Cobalt-60 U 0.00256 +/-0.0168 Europium-152 U -0.0364 +/-0.0448 Europium-154 U 0.035 +/-0.0576 Europium-155 U 0.00602 +/-0.0573 Lead-212 0.748 +/-0.0555 Lead-214 0.595 +/-0.0701 Manganese-54 U -0.0121 +/-0.0183 Niobium-94 U 0.00366 +/-0.0163 Potassium-40 13.5 +/-0.799 Radium-226 0.502 +/-0.0823 Silver-108m U 0.000168 +/-0.0154 Thallium-208 0.252 +/-0.0377 0.0418 0.0571 0.111 0.028 0.0185 0.0152 0.014 0.0372 0.0501 0.0499 0.0227 0.0273 0.015 0.0144 0.103 0.028 0.0131 0.0139+/-0.132+/-0.0642+/-0.237+/-0.0823+/-0.026+/-0.0253+/-0.0168+/-0.0448+/-0.0576+/-0.0573+/-0.0555+/-0.0701+/-0.0183+/-0.0163+/-0.799+/-0.0823+/-0.0154+/-0.0377 0.0905 0.118 0.235 0.0589 0.039 0.0321 0.0306 0.0779 0.107 0.103 0.047 0.0571 0.0317 0.0303 0.231 0.0589 0.0276 0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1411 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 10/09/06 1211 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-027F Project: YANK01204 Sample ID: 173429007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-028F 173429008 TS 26-SEP-06 09-OCT-06 Client 6.72%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.864 +/-0.178 Americium-241 U -0.0233 +/-0.0765 Bismuth-212 0.445 +/-0.333 Bismuth-214 0.436 +/-0.0953 Cesium-134 U 0.0341 +/-0.0377 Cesium- 137 0.0596 +/-0.0297 Cobalt-60 U 0.00503 +/-0.0226 Europium-152 U -0.0127 +/-0.0635 Europium-154 U -0.0266 +/-0.0666 Europium-155 U 0.0468 +/-0.0594 Lead-212 0.703 +/-0.0826 Lead-214 0.584 +/-0.0986 Manganese-54 U 0.0109 +/-0.0212 Niobium-94 U -0.00114 +/-0.0202 Potassium-40 12.4 +/-1.14 Radium-226 0.436 +/-0.0953 Silver-108m U 0.00362 +/-0.0194 Thallium-208 0.205 +/-0.0495 0.0627 0.0585 0.148 0.033 0.0239 0.0151 0.0193 0.0492 0.0529 0.053 0.0281 0.0308 0.0189 0.0175 0.129 0.033 0.0168 0.0179+/-0.178+/-0.0765+/-0.333+/-0.0953+/-0.0377+/-0.0297+/-0.0226+/-0.0635+/-0.0666+/-0.0594+/-0.0826+/-0.0986+/-0.0212+/-0.0202+/-1.14+/-0.0953+/-0.0194+/-0.0495 0.125 0.117 0.295 0.066 0.0477 0.0302 0.0385 0.0984 0.106 0.106 0.0562 0.0616 0.0379 0.035 0.258 0.066 0.0336 0.0357 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1426 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB 1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-028F Project: YANK01204 Sample ID: 173429008 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-029F 173429009 TS 26-SEP-06 09-OCT-06 Client 12%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.689 +/-0.205 Americium-241 U 0.00775 +/-0.0963 Bismuth-212 UI 0.00 +/-0.395 Bismuth-214 UI 0.00 +/-0.110 Cesium-134 U 0.0388 +/-0.0318 Cesium- 137 0.0804 +/-0.0483 Cobalt-60 U 0.0103 +/-0.0264 Europium-152 U 0.0389 +/-0.101 Europium-154 U 0.0532 +/-0.0833 Europium-155 U 0.0361 +/-0.0685 Lead-212 0.701 +/-0.0886 Lead-214 0.633 +/-0.110 Manganese-54 U 0.00795 +/-0.026 Niobium-94 U -0.0143 +/-0.0431 Potassium-40 11.8 +/-1.12 Radium-226 0.457 +/-0.110 Silver-108m U -0.00296 +/-0.021 Thallium-208 0.261 +/-0.0556 0.0745 0.0742 0.157 0.0803 0.0286 0.0184 0.023 0.0542 0.0661 0.060 0.0299 0.0373 0.020 0.0189 0.140 0.0383 0.0177 0.0204+/-0.205+/-0.0963+/-0.395+/-0.110+/-0.0318+/-0.0483+/-0.0264+/-0.101+/-0.0833+/-0.0685+/-0.0886+/-0.110+/-0.026+/-0.0431+/-1.12+/-0.110+/-0.021+/-0.0556 0.149 0.148 0.313 0.161 0.0571 0.0367 0.046 0.108 0.132 0.120 0.0597 0.0745 0.040 0.0377 0.280 0.0766 0.0354 0.0408 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/10/06 1426 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMBI 10/09/06 1211 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:*g A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-029F Proiect: YANK01204 Sample ID: 173429009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-030F 173429010 TS 26-SEP-06 09-OCT-06 Client 8.37%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.906 U 0.067 U 0.386 0.586 U -0.0184 U 0.0458 U 0.00348 U -0.00247 U 0.0564 UI 0.00 0.667 0.667 U 0.00647 U 0.00262 11.5 0.586 U 0.00473 0.271+/-0.239+/-0.0425+/-0.254+/-0.127+/-0.0378+/-0.0342+/-0.0376+/-0.105+/-0.112+/-0.0802+/-0.0919+/-0.119+/-0.0324+/-0.0295+/-1.35+/-0.127+/-0.0235+/-0.0574 0.0933 0.0346 0.242 0.0531 0.0309 0.0322 0.0271 0.0609 0.0986 0.0538 0.0321 0.0439 0.0282 0.0256 0.248 0.0531 0.0202 0.0264+/-0.239+/-0.0425+/-0.254+/-0.127+/-0.0378+/-0.0342+/-0.0376+/-0.105+/-0.112+/-0.0802+/-0.0919+/-0.119+/-0.0324+/-0.0295+/-1.35+/-0.127+/-0.0235+/-0.0574 0.187 0.0692 0.484 0.106 0.0618 0.0644 0.0543 0.122 0.197 0.108 0.0642 0.0878 0.0563 0.0512 0.495 0.106 0.0404 0.0528 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1427 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-030F Proiect: YANK01204 Sample ID: 173429010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification*

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Report Date: October 12, 2006 Project: Soils PO# 002332 Client Sample ID: 9520-0003-031F Project: YANK01204 Sample ID: 173429011 Client ID: YANKO0I Matrix: TS Vol. Recv.: Collect Date: 26-SEP-06 Receive Date: 09-OCT-06 Collector:

Client Moisture:

10.4%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.771 +/-0.161 Americium-241 U -0.00729 +/-0.0882 Bismuth-212 0.434 +/-0.195 Bismuth-214 0.477 +/-0.078 Cesium- 134 UI 0.00 +/-0.0263 Cesium-137 0.0461 +/-0.0276 Cobalt-60 U -0.00186 +/-0.0157 Europium-152 U -0.0437 +/-0.0398 Europium-154 U -0.00674 +/-0.0498 Europium-155 UI 0.00 +/-0.0609 Lead-212 0.764 +/-0.0761 Lead-214 0.539 +/-0.0777 Manganese-54 U 0.00846 +/-0.0159 Niobium-94 U 0.00588 +/-0.0143 Potassium-40 12.4 +/-1.06 Radium-226 0.477 +/-0.078 Silver-108m U-0.000156

+/-0.0134 Thallium-208 0.217 +/-0.0382 0.0437 0.0759 0.103 0.0239 0.0166 0.0137 0.0133 0.0322 0.0422 0.0356 0.0191 0.0241 0.0138 0.0125 0.110 0.0239 0.0112 0.0122+/-0.161+/-0.0882+/-0.195+/-0.078+/-0.0263+/-0.0276+/-0.0157+/-0.0398+/-0.0498+/-0.0609+/-0.0761+/-0.0777+/-0.0159+/-0.0143+/-1.06+/-0.078+/-0.0134+/-0.0382 0.0922 0.155 0.216 0.0499 0.0347 0.0286 0.0285 0.0666 0.0895 0.0729 0.0393 0.0498 0.0289 0.026 0.239 0.0499 0.0232 0.0254 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/10/06 1413 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 TMB1 10/09/06 1211 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-03 IF Project: YANK01204 Sample ID: 173429011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-035F 173429012 TS 29-SEP-06 06-OCT-06 Client 6.38%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.671 +/-0.197 Americium-241 U -0.129 +/-0.0787 Bismuth-212 0.320 +/-0.383 Bismuth-214 0.512 +/-0.0883 Cesium-134 U 0.033 +/-0.0329 Cesium-137 0.0519 +/-0.034 Cobalt-60 U 0.0269 +/-0.0229 Europium-152 U -0.0438 +/-0.0676 Europium-154 U -0.0156 +/-0.0718 Europium-155 U -0.0284 +/-0.0608 Lead-212 0.677 +/-0.0782 Lead-214 0.584 +/-0.108 Manganese-54 U 0.0157 +/-0.0269 Niobium-94 U -0.00582 +/-0.0216 Potassium-40 11.8 +/-1.18 Radium-226 0.512 +/-0.0883 Silver-108m U -0.00466 +/-0.020 Thallium-208 0.212 +/-0.0467 0.0615 0.0646 0.148 0.0341 0.0237 0.0178 0.0219 0.0483 0.0594 0.0515 0.0279 0.0347 0.0206 0.0177 0.179 0.0341 0.0169 0.0175+/-0.197+/-0.0787+/-0.383+/-0.0883+/-0.0329+/-0.034+/-0.0229+/-0.0676+/-0.0718+/-0.0608+/-0.0782+/-0.108+/-0.0269+/-0.0216+/-1.18+/-0.0883+/-0.020+/-0.0467 0.133 0.133 0.317 0.0725 0.0503 0.0382 0.0478 0.102 0.130 0.106 0.0581 0.0729 0.0439 0.0377 0.397 0.0725 0.0357 0.0373 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1413 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/08/06 1251 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defmed as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-035F Project: YANK01204 Sample ID: 173429012 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-036F 173429013 TS 29-SEP-06 06-OCT-06 Client 8.02%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.678 +/-0.205 Americium-241 U 0.00563 +/-0.124 Bismuth-212 0.762 +/-0.314 Bismuth-214 0.621 +/-0.0932 Cesium- 134 UI 0.00 +/-0.0281 Cesium- 137 U 0.0499 +/-0.035 Cobalt-60 U 0.0225 +/-0.0241 Europium-152 U -0.0084 +/-0.0585 Europium-154 U 0.0111 +/-0.0645 Europium-155 U 0.0121 +/-0.059 Lead-212 0.741 +/-0.0681 Lead-214 0.697 +/-0.0948 Manganese-54 U 0.0234 +/-0.0302 Niobium-94 U 0.000568 +/-0.0208 Potassium-40 12.8 +/-1.04 Radium-226 0.621 +/-0.0932 Silver-108m U -0.00405 +/-0.019 Thallium-208 0.243 +/-0.0539 0.0563 0.0806 0.133 0.0298 0.0285 0.0237 0.0214 0.0478 0.0564 0.0525 0.0311 0.0341 0.0173 0.0177 0.147 0.0298 0.0164 0.0184+/-0.205+/-0.124+/-0.314+/-0.0932+/-0.0281+/-0.035+/-0.0241+/-0.0585+/-0.0645+/-0.059+/-0.0681+/-0.0948+/-0.0302+/-0.0208+/-1.04+/-0.0932+/-0.019+/-0.0539 0.125 0.167 0.291 0.0648 0.0606 0.0505 0.0477 0.101 0.126 0.109 0.0649 0.0724 0.0379 0.0381 0.345 0.0648 0.035 0.0395 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1740 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 10/08/06 1251 576541 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-036F Project: YANK01204 Sample ID: 173429013 ClientID:

YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-037F 173429014 TS 29-SEP-06 06-OCT-06 Client 10.1%Project: Client ID: Vol. Recv.: YANKO01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 B ismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.872 U -0.08 0.496 0.646 U 0.0427 0.125 U 0.0369 U -0.0142 U 0.048 U 0.0285 0.726 0.621 U -0.00503 U-0.000164 11.4 0.646 U 0.000684 0.191+/-0.210+/-0.125+/-0.327+/-0.101+/-0.0431+/-0.0497+/-0.0315+/-0.063+/-0.079+/-0.062+/-0.0686+/-0.0991+/-0.0232+/-0.0222+/-0.986+/-0.101+/-0.0194+/-0.0524 0.0673 0.0919 0.153 0.0311 0.0269 0.021 0.0227 0.0512 0.0711 0.0566 0.0278 0.0371 0.0187 0.0186 0.205 0.0311 0.017 0.0183+/-0.210+/-0.125+/-0.327+/-0.101+/-0.0431+/-0.0497+/-0.0315+/-0.063+/-0.079+/-0.062+/-0.0686+/-0.0991+/-0.0232+/-0.0222+/-0.986+/-0.101+/-0.0194+/-0.0524 0.148 0.192 0.331 0.0675 0.0575 0.0451 0.0504 0.108 0.156 0.118 0.0583 0.0785 0.0407 0.0401 0.461 0.0675 0.0363 0.0394 p(i/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1740 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/08/06 1251 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-037F Project: YANK01204 Sample ID: 173429014 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 12, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9520-0003-038F 173429015 TS 29-SEP-06 06-OCT-06 Client 7.52%Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.734 +/-0.155 Americium-241 U -0.119 +/-0.108 Bismuth-212 UT 0.00 +/-0.577 Bismuth-214 0.565 +/-0.105 Cesium-134 U 0.0465 +/-0.0297 Cesium-137 0.124 +/-0.0474 Cobalt-60 U 0.00888 +/-0.0243 Europium-152 U 0.0475 +/-0.067 Europium-154 U -0.0332 +/-0.0783 Europium-155 U 0.0289 +/-0.0645 Lead-212 0.716 +/-0.0773 Lead-214 0.538 +/-0.0987 Manganese-54 U -0.0138 +/-0.0249 Niobium-94 U -0.00995 +/-0.0225 Potassium-40 10.1 +/-0.944 Radium-226 0.565 +/-0.105 Silver-108m U 0.00639 +/-0.0219 Thallium-208 0.198 +/-0.0509 0.070 0.0809 0.137 0.0391 0.0258 0.0226 0.0213 0.0533 0.0629 0.0565 0.0296 0.0366 0.0198 0.0185 0.155 0.0391 0.0187 0.0174+/-0.155+/-0.108+/-0.577+/-0.105+/-0.0297+/-0.0474+/-0.0243+/-0.067+/-0.0783+/-0.0645+/-0.0773+/-0.0987+/-0.0249+/-0.0225+/-0.944+/-0.105+/-0.0219+/-0.0509 0.152 0.167 0.296 0.0831 0.0549 0.0479 0.0472 0.112 0.138 0.117 0.0617 0.0772 0.0427 0.0394 0.356 0.0831 0.0395 0.0374 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/10/06 1741 576803 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/08/06 1251 576541 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 12, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-038F Project: YANK01204 Sample ID: 173429015 ClientID:

YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.48 QUALITY CONTROL DATA 49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: October 12, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

173429 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 576803 QC1201201885 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 173429001 DUP 0.669 Uncert: +/-0.167 TPU: +/-0.167 U 0.0158 Uncert: +/-0.0993 TPU: +/-0.0993 0.636 Uncert: +/-0.338 TPU: +/-0.338 0.524 Uncert: +/-0.103 TPU: +/-0.103 UI 0.00 Uncert: +/-0.0401 TPU: +/-0.0401 0.0868 Uncert: +/-0.0408 TPU: +/-0.0408 U 0.0098 Uncert: +/-0.0245 TPU: +/-0.0245 U 0.016 Uncert: +/-0.0604 TPU: +/-0.0604 U 0.0853 Uncert: +/-0.0845 TPU: +/-0.0845 U 0.0625 Uncert: +/-0.0553 TPU: +/-0.0553 0.665 Uncert: +/-0.0653 TPU: +/-0.0653 0.609 Uncert: +/-0.0981 TPU: +/-0.0981 U 0.0081 Uncert: +/-0.0243 TPU: +/-0.0243 U 0.00664 Uncert: +/-0.021 TPU: +/-0.021 0.684+/-0.171+/-0.171 U -0.0698+/-0.0944+/-0.0944 0.398+/-0.249+/-0.249 0.557+/-0.109+/-0.109 U 0.0301+/-0.0326+/-0.0326 0.0709+/-0.0374+/-0.0374 U -0.01+/-0.0223+/-0.0223 U 0.029+/-0.0523+/-0.0523 U 0.0471+/-0.0679+/-0.0679 U 0.0477+/-0.055+/-0.055 0.731+/-0.0652+/-0.0652 0.693+/-0.099+/-0.099 U 0.000224+/-0.0218+/-0.0218 U -0.00917+/-0.0191+/-0.0191 pCi/g 2 pCi/g 317 pCi/g 46 pCi/g 6 pCi/g 70 pCi/g 20 pCi/g 17900 pCi/g 58 pCi/g 58 pCi/g 27 pCi/g 9 pCi/g 13 pCi/g 189 pCi/g 1250 (0%- 100%) MJHI 10/12/06 10:16 (0%- 100%)(0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -100%)(0%- 100%)(0%- 20%)(0%-20%)(0%- 100%)(0%- 100%)50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173429 Page 2 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 576803 Potassium-40 Radium-226 Silver- 108m Thallium-208 11.2 Uncert: +/-0.949 TPU: +/-0.949 0.524 Uncert: +/-0.103 TPU: +/-0.103 u 0.0278 Uncert: +/-0.0208 TPU: +/-0.0208 0.204 Uncert: +/-0.053 TPU: +/-0.053 10.9+/-0.876+/-0.876 0.557+/-0.109+/-0.109-0.0087+/-0.0167+/-0.0167 0.236+/-0.0418+/-0.0418 pCug 3 pCi/g 6 pCi/g 382 pCi/g 14 (0% -20%)(0%- 100%)(0%- 100%)(0% -100%)U QC1201201886 Actinium-228 Americium-241 LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.55 Uncert: TPU: 14.3 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.0901+/-0.586+/-0.586 23.8+/-0.543+/-0.543 U 0.891+/-1.14+/-1.14 U -0.087+/-0.223+/-0.223 U 0.103+/-0.148+/-0.148 10.6+/-0.517+/-0.517 14.9+/-0.677+/-0.677 U 0.0502+/-0.259+/-0.259 U -0.0216+/-0.295+/-0.295 U 0.111+1-0.244+/-0.244 U -0.0772+/-0.155+/-0.155 U 0.103+/-0.193 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 102 (75%-125%)

10/10/06 16:25 111 (75%-125%)

105 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Uncert: 51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173429 Page 3 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 576803 TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC1201201884 Actinium-228 Americium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.193 U -0.0122+/-0.140+/-0.140 U -0.0052+/-0.120+/-0.120 U 0.806+/-0.822+/-0.822 U -0.087+/-0.223+/-0.223 U 0.0776+/-0.110+/-0.110 U 0.0912+/-0.117+/-0.117 U 0.066+/-0.0443+/-0.0443 U -0.0193+/-0.0707+/-0.0707 U -0.0381+/-0.0917+/-0.0917 U 0.029+/-0.0461+/-0.0461 U -1.530E-05

+/-0.0129+/-0.0129 U -0.00234+/-0.0115+/-0.0115 U 0.00601+/-0.0136+/-0.0136 U 0.00342+/-0.0355+/-0.0355 U 0.0343+/-0.040+/-0.040 U 0.0333 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

10/10/06 17:41 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173429 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 576803 Uncert: +/-0.0335 TPU: +/-0.0335 Lead-212 U 0.00562 pCi/g Uncert: +/-0.0281 TPU: +/-0.0281 Lead-214 U 0.00442 pCi/g Uncert: +/-0.0399 TPU: +/-0.0399 Manganese-54 U -0.0059 pCi/g Uncert: +/-0.0133 TPU: +/-0.0133 Niobium-94 U -0.00189 pCi/g Uncert: +/-0.0107 TPU: +/-0.0107 Potassium-40 U 0.282 pCi/g Uncert: +/-0.123 TPU: +/-0.123 Radium-226 U 0.029 pCi/g Uncert: +/-0.0461 TPU: +/-0.0461 Silver-108m U -0.00109 pCi/g Uncert: +/-0.00954 TPU: +/-0.00954 Thallium-208 U 0.0137 pCi/g Uncert: +/-0.0159 TPU: +/-0.0159 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173429 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.54 General Narrative 1 General Narrative for Connecticut Yankee Atomic Power Co.Work Order: 173435 SDG: MSR#06-1334 October 12, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The sample arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on October 06, 2006 for analysis.

Shipping container temperature was checked, documented, and within specifications.

The sample was delivered with proper chain of custody documentation and signatures.

All sample containers arrived without any visible signs of tampering or breakage.Sample Identification The laboratory received the following sample: Laboratory Sample Identification Description 173435001 9520-0003-039F Items of Note There are no items to note.Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.Analytical Request One soil sample was analyzed for FSSALL.Data Package The enclosed data package contains the following sections:

General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions:

Radiochemistry.

2 I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager 3 List of current GEL Certifications as of 12 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 0115ICA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4 Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00603 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested "Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 : 843 556 8171. Attn. Cheryl Jones COO Priority:

F-1 30 D. I- 14 D. Z 7 D. 1-3 D. Container

-; <Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Sample ID Code Code Code : 9520-0003-039F 10/4/06 1334 TS G BP X NOTES: PO #: 002332 MSR #: 06- 1334 SSWP# NA E LTP QA El Radwaste QA L] Non QA 1) (A Ri h )- 0 (. 0 Da(t 1) Re in hed Date/Time eceived By Date/Time 3) binquished By Dte/Time 4) Received By Date/Time Samples Shipped Via: E Fed Ex[I ups[0 Hand LI Other 7B900 L n Bill of Lading #~Internal Container Ternp.: 1,q Dg-- __Dg C~ustody Sealed?Custod Seal I.~ ntact?4-'N Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List.Date/Time Received:

IO .h SD ;# NI ..t ;:ýWork Order Number: 1T1- Li , -41 11iA- .. .-Shipping Container ID ,Chain of Custody# oncot c 1. Custody Seals orishipping container intact? Yes No.2. Custody Seals dated and signed? Yes No [I.3. Chain-of-Custody record present? Yes o[No C, y* 4. Cooler temperature " t *5. Vermiculite/packing materials is: Wet [ ] Dry..6.' Number of samples in shipping container:

.7. Sample holding times exceeded?

Yes [ ] No 8. Samples have:'_\tape hazard labels custody seals -appropriate sample labels 9. Samples are., in good condition leaking L broken ... .have air bubbles 10. Were any anomalies identified in sample receipt? Yes [1 No 11. ..Description of anomalies (include sample numbers): Sample Custodian/Lab ratory: .' D / 1 T e l e p h o n e d to : O n D a t e -""D"a t Telephoned to:O"_B "".-7 Data Review Qualifier Definitions 8

Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound* Result is less than value reported* Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171
  • Fax9343) 766-1178 www.gel.com RADIOLOGICAL ANALYSIS 10 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 173435 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 577050 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201202528 Method Blank (MB)1201202529 173435001(9520-0003-039F)

Sample Duplicate (DUP)1201202530 173435001(9520-0003-039F)

Matrix Spike (MS)1201202531 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time 11 All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201202529 (9520-0003-039F) was recounted due to a negative result greater than three times the error.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: AIphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 577051 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201202532 Method Blank (MB)1201202533 173435001(9520-0003-039F)

Sample Duplicate (DUP)1201202534 173435001(9520-0003-039F)

Matrix Spike (MS)1201202535 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.12 Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 577052 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 13 Sample ID Client ID 173435001 9520-0003-039F 1201202536 Method Blank (MB)1201202537 173435001(9520-0003-039F)

Sample Duplicate (DUP)1201202538 173435001(9520-0003-039F)

Matrix Spike (MS)1201202539 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.14 Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 576804 Prep Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201201887 Method Blank (MB)1201201888 173432001(9520-0003-032F)

Sample Duplicate (DUP)1201201889 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173432001 (9520-0003-032F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.15 Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201201887 (MB) was recounted due to count room error.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The sample and duplicate 1201201888 (9520-0003-032F) for Bi-214 and T1-208 did not meet the relative percent difference requirement, however when the relative error ratio was calculated, precision was shown at 2.26279 for Bi-214 and 1.66238 for TI-208.Qualifier information Qualifier Reason Analyte Sample UT Data rejected due to high peak-width.

Bismuth-212 173435001 UI Data rejected due to low abundance.

Actinium-228 173435001 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 577080 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201202607 Method Blank (MB)1201202608 173435001(9520-0003-039F)

Sample Duplicate (DUP)1201202609 173435001(9520-0003-039F)

Matrix Spike (MS)1201202610 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.16 Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 576582 Sample ID Client ID 173435001 9520-0003-039F 1201201414 Method Blank (MB)1201201415 173434001(9506-0-6C)

Sample Duplicate (DUP)17 1201201416 173434001(9506-0-6C)

Matrix Spike (MS)1201201417 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173434001 (9506-0-6C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 18 Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 576967 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201202288 Method Blank (MB)1201202289 173329001(9312-0002-01-SUB08)

Sample Duplicate (DUP)1201202290 173329001(9312-0002-01-SUB08)

Matrix Spike (MS)1201202291 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173329001 (9312-0002-01-SUB08).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.19 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 576968 Prep Batch Number: 576639 Dry Soil Prep GL-RAD-A-021 Batch Number: 576546 Sample ID Client ID 173435001 9520-0003-039F 1201202292 Method Blank (MB)1201202293 173329001(9312-0002-01-SUB08)

Sample Duplicate (DUP)1201202294 173329001(9312-0002-01-SUB08)

Matrix Spike (MS)1201202295 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

20 Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173329001 (9312-0002-01-SUB08).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 576969 Sample ID Client ID 173435001 9520-0003-039F 1201202296 Method Blank (MB)1201202297 173435001(9520-0003-039F)

Sample Duplicate (DUP)1201202298 173435001(9520-0003-039F)

Matrix Spike (MS)1201202299 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

21 Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s): Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201202299 (LCS) was recounted due to the quench number being outside the calibration range.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 578362 Sample ID Client ID 173435001 9520-0003-039F 1201205173 Method Blank (MB)1201205174 173435001(9520-0003-039F)

Sample Duplicate (DUP)22 1201205175 173435001(9520-0003-039F)

Matrix Spike (MS)1201205176 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 173435001 (9520-0003-039F) were reprepped due to high MDAs. The background was recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.23 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified theinformation presented in this case narrative:

Reviewer/Date:

P 6&"wti 24 SAMPLE DATA

SUMMARY

25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1334 GEL Work Order: 173435 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 16, 2006 Client Sample ID: 9520-0003-039F Proiect: YANK01204 Sample ID: 173435001 Client ID: YANK001 Matrix: TS Vol. Recv.: Collect Date: 04-OCT-06 Receive Date: 06-OCT-06 Collector:

Client Moisture:

11.2%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0368+/-0.114 0.0738 +/-0.114 Curium-242 U -0.0273 +/-0.0309 0.059 +/-0.0312 Curium-243/244 U -0.0589 +/-0.122 0.128 +/-0.122 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00643 +/-0.054 0.0241 +/-0.0541 Plutonium-239/240 U 0.075 +/-0.109 0.0538 +/-0.109 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -5.64 +/-8.51 7.39 +/-8.51 0.247 0.221 0.355 0.121 0.180 pCi/g pCi/g pCi/g pCi/g pCi/g MXA M MXA I MXA I 10/11/06 0915 577050 1 10/11/06 0721 577051 2 10/12/06 1549 577052 3 15.5 pCi/g Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 UI Americium-241 U Bismuth-212 U1 Bismuth-214 Cesium-134 U Cesium-137 U Cobalt-60 U Europium-152 U Europium-154 U C Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00 0.0285 0.00 0.543 0.0137 0.053-0.0251 0.00593).000552 0.0599 0.680 0.608 0.0136 0.0208 11.8 0.543 0.00276 0.231+/-0.248+/-0.0414+/-0.528+/-0.117+/-0.0319+/-0.0334+/-0.0394+/-0.0774+/-0.0963+/-0.0822+/-0.0906+/-0.111+/-0.0325+/-0.0279+/- 1.22+/-0.117+/-0.0254+/-0.0664 0.198 0.0328 0.193 0.050 0.0285 0.032 0.0299 0.0549 0.0801 0.0494 0.0312 0.0397 0.0288 0.0255 0.287 0.050 0.0215 0.0258+/-0.248+/-0.0414+/-0.528+/-0.117+/-0.0319+/-0.0334+/-0.0394+/-0.0774+/-0.0963+/-0.0822+/-0.0906+/-0.111+/-0.0325+/-0.0279+/-1.22+/-0.117+/-0.0254+/-0.0664 0.396 0.0656 0.385 0.100 0.057 0.0639 0.0598 0.110 0.160 0.0987 0.0623 0.0794 0.0575 0.051 0.574 0.100 0.0429 0.0517 0.013 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/12/06 1718 576804 4 KSD1 10/11/06 2226 577080 5 0.00169 +/-0.00745 0.00617 +/-0.00745 27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 16, 2006 Client Sample ID: Sample ID: 9520-0003-039F 173435001 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.10 Liquid Scint C14, Solid AllFSS Carbon-14 U 0.0477 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.3 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.00 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0885 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-5.93 4.81 +/-5.93 10.2+/-0.111 0.0916 +/-0.111 0.188+/-26.9 18.4 +/-26.9 38.4+/-11.5 9.62 +/-11.5 20.1+/-0.226 0.192 +/-0.226 0.396 pCi/g pCi/g pCi/g pCi/g pCi/g DFAI 10/10/06 0801 576969 6 AXD2 10/13/06 1830 578362 7 MXPI 10/10/06 2311 576967 9 MXP1 10/11/06 1605 576968 10 EGDI 10/11/06 1502 576582 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 10/07/06 1057 576546 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1 1-RC Modified 3 DOE EML HASL-300, Pu- I1-RC Modified 4 EML HASL 300,4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-i, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS 83 92 74 84 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 16, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9520-0003-039F Project: YANK01204 Sample ID: 173435001 Client ID: YANK00I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 80 (15%-1 25%)Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 61 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.29 I QUALITY CONTROL DATA 30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: October 16, 2006 Page 1 of 9 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

173435 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 577050 QC 1201202529 Americium-241 Curium-242 Curium-243/244 QC1201202531 Americium-241 Curium-242 Curium-243/244 QCI1201202528 Americium-241 173435001 DUP U 0.0368 Uncert: +/-0.114 TPU: +/-0.114 U -0.0273 Uncert: +/-0.0309 TPU: +/-0.0312 U -0.0589 Uncert: +/-0.122 TPU: +/-0.122 LCS MB 13.2 Uncert: TPU: Uncert: TPU: 15.9 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0696+/-0.0529+/-0.0536 U -0.0324+/-0.0835+/-0.0836 U 0.125+/-0.200+/-0.201 12.7+/-1.28+/-2.16 U 0.0597+/-0.0953+/-0.0957 14.8+/-1.39+/-2.47 U -0.0869+/-0.200+/-0.200 U 0.0299+/-0.131+/-0.131 U 0.116+/-0.237+/-0.237 pCi/g 649 pCi/g 17 pCi/g 556 (0% -100%) vAXA1 (0%- 100%)(0%- 100%)Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g PCi/g pCi/g 96 (75%-125%)

93 (75%-125%)

10/12/06 12:04 10/11/06 09:15 Curium-243/244 QC1201202530 Americium-241 173435001 MS Curium-242 13.7 Uncert: TPU: Uncert: TPU: 16.6 Uncert: TPU: U 0.0368+/-0.114+/-0.114 U -0.0273+/-0.0309+/-0.0312 U -0.0589+/-0.122+/-0.122 U 12.1+/- 1.26+/-2.07-0.0497+/-0.0398+/-0.0404 16.0+/-1.44+/-2.61 88 (75%-125%)

Curium-243/244 96 (75%-125%)

Batch 577051 QC1201202533 173435001 DUP Plutonium-238 U -0.00643 U 0.0489 pCi/g 261 (0% -100%) 4XA1 10/11/06 08:16 31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Alpha Spec Batch 577051 Plutonium-239/240 Uncert: +/-0.054 TPU: +/-0.0541 U 0.075 Uncert: +/-0.109 TPU: +/-0.109 QC1201202535 LCS Plutonium-238 Plutonium-239/240 QC1201202532 MB Plutonium-238 Plutonium-239/240 QC1201202534 173435001 MS Plutonium-238 Plutonium-239/240 Uncert: TPU: 12.2 Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0781+/-0.0783 U -0.00555+/-0.0618+/-0.0618 U 0.0826+/-0.120+/-0.120 10.4+/-1.09+/-1.62 U -0.0848+/-0.0873+/-0.0877 U 0.0926+/-0.150+/-0.150 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 232 (0%- 100%)(75%-125%)

10/11/06 08:16 85 (75%-125%)

10/11/06 07:22 U -0.00643 Uncert: +/-0.054 TPU: +/-0.0541 12.7 U 0.075 Uncert: +/-0.109 TPU: +/-0.109 U 0.0362+/-0.0817+/-0.0818 10.8+/-1.09+/-1.64 (75%-125%)

10/11/06 08:16 84 (75%-125%)

Batch 577052 QC1201202537 Plutonium-241 173435001 DUP QC1201202539 LCS Plutonium-241 QC1201202536 MB Plutonium-241 QC1201202538 173435001 MS Plutonium-241 Rad Gamma Spec Batch 576804 QC1201201888 173432001 DUP Actinium-228 U Uncert: TPU: Uncert: TPU: Uncert: TPU: 144 U Uncert: TPU:-5.64+/-8.51+/-8.51 U -3.09+/-7.05+/-7.05 124+/-12.9+/-17.9 U -3.41+/-8.36+/-8.36 pCi/g 0 (0% -100%) VIXA1 pCi/g pCi/g pCi/g 87 (75%-125%)

10/12/06 16:22 10/12/06 16:54 10/12/06 16:06 10/12/06 16:38-5.64+/-8.51+/-8.51 115+/-11.2+/-15.7 80 (75%-125%)

0.807+/-0.151 Uncert: 0.990+/-0.252+/-0.252 pCi/g 20 (0% -100%) MJH1 10/12/06 17:42 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 576804 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.151 u 0.0208 Uncert: +/-0.116 TPU: +/-0.116 0.720 Uncert: +/-0.249 TPU: +/-0.249 0.554 Uncert: +/-0.0875 TPU: +/-0.0875 UI 0.00 Uncert: +/-0.0361 TPU: +/-0.0361 0.0461 Uncert: +/-0.0279 TPU: +/-0.0279 u -0.0122 Uncert: +/-0.0193 TPU: +/-0.0193 u -0.0204 Uncert: +/-0.0484 TPU: +/-0.0484 u 0.0428 Uncert: +/-0.0569 TPU: +/-0.0569 u 0.00564 Uncert: +/-0.0696 TPU: +/-0.0696 0.798 Uncert: +/-0.0616 TPU: +/-0.0616 0.638 Uncert: +/-0.0749 TPU: +/-0.0749 U -0.0022 Uncert: +/-0.0198 TPU: +/-0.0198 U 0.0143 Uncert: +/-0.0181 TPU: +/-0.0181 13.8 Uncert: +/-0.824 TPU: +/-0.824 0.554 Uncert: +/-0.0875 TPU: +/-0.0875 U 0.000225 Uncert: +/-0.0161 U 0.0313+/-0.0519+/-0.0519 0.872+/-0.536+/-0.536 0.781+/-0.176+/-0.176 U 0.0223+/-0.0481+/-0.0481 U 0.0664+/-0.0774+/-0.0774 U 0.0212+/-0.0343+/-0.0343 U -0.0365+/-0.0833+/-0.0833 U 0.062+/-0.109+/-0.109 U 0.0466+/-0.082+/-0.082 0.788+/-0.0889+/-0.0889 0.645+/-0.122+/-0.122 U 0.0124+/-0.040+/-0.040 U 0.0259+/-0.035+/-0.035 12.2+/-1.36+/-1.36 0.781+/-0.176+/-0.176 U 0.0115+/-0.0281 pCi/g 40 pCi/g 19 (0%- 100%)(0% -100%)pCi/g 34* (0%- 100%)Lead-212 Lead-214 pCi/g 92 pCi/g 36 pCi/g 742 pCi/g 57 pCi/g 37 pCi/g 157 pCi/g I pCi/g 1 pCi/g 286 pCi/g 58 pCi/g 13 pCi/g 34 pCi/g 192 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0% -100%)(0% -100%)(0% -20%)(0% -100%)(0%- 100%)Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m 33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Parmname Rad Gamma Spec Batch 576804 Thallium-208 QC1201201889 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Page 4 of 9 NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time TPU: Uncert: TPU: Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.55 Uncert: TPU: 14.3 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0161 0.231+/-0.0401+/-0.0401+/-0.0281 0.300+/-0.0703+/-0.0703 U 0.0685+/-0.531+/-0.531 24.7+/-2.62+/-2.62 U 0.235+/-0.989+/-0.989 U -0.0375+/-0.233+/-0.233 U -0.00479+/-0.147+/-0.147 9.73+/-0.768+/-0.768 15.1+/-1.04+/-1.04 U -0.287+/-0.311+/-0.311 U 0.112+/-0.276+/-0.276 U -0.0442-4-0.328+/-0.328 U -0.125+/-0.159+/-0.159 U -0.193+/-0.224+/-0.224 U 0.0482+/-0.133+/-0.133 U 0.0277+/-0.116+/-0.116 U 0.581 pCi/g 26 (0% -100%)pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 10/12/06 19:15 106 (75%-125%)

102 (75%-125%)

106 (75%-125%)

34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 576804 Radium-226 Silver- 108m Thallium-208 QC1201201887 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.04+/-1.04 U -0.0375+/-0.233+/-0.233 U -0.0727+/-0.114+/-0.114 U -0.0423+/-0.118+/-0.118 U -0.00601+/-0.0434+/-0.0434 U -0.0137+/-0.0533+/-0.0533 U 0.0252+/-0.0887+/-0.0887 U 0.0258+/-0.0337+/-0.0337 U 0.000666+/-0.0118+/-0.0118 U -0.00269+/-0.0111+/-0.0111 U -0.000359+/-0.0142+/-0.0142 U -0.00823+/-0.0289+/-0.0289 U 0.0206+/-0.0308+/-0.0308 U 0.0121+/-0.0283+/-0.0283 U 0.000673+/-0.0259+/-0.0259 U 0.0286+/-0.045+1-0.045 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 10/13/06 12:27 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-2 14 35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel corn QC Summary Workorder:

173435 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD %REC% Range AnIst Date Time Rad Gamma Spec Batch 576804 Manganese-54 Niobium-94 Potassium-40 Radium-226 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.00755+/-0.00957

+/-0.00957 U -0.000868+/-0.0108+/-0.0108 U 0.150+/-0.137+/-0.137 U 0.0258+/-0.0337+/-0.0337 U 0.00351+/-0.0101+/-0.0101 U 0.00714+/-0.0164+/-0.0164 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Silver- 108m Thallium-208 Rad Gas Flow Batch 577080 QC1201202608 173435001 DUP Strontium-90 QC1201202610 LCS Strontium-90 QC 1201202607 MB Strontium-90 QC1201202609 173435001 MS Strontium-90 Rad Liquid Scintillation Batch 576582 QC1201201415 173434001 DUP Technetium-99 QC1201201417 LCS Technetium-99 QC1201201414 MB Technetium-99 U 0.00169 Uncert: +/-0.00745 TPU: +/-0.00745 U 0.0107+/-0.0071+/-0.00711 1.28+/-0.0853+/-0.0898 pCi/g 0 (0% -100%) KSDI 1.54 Uncert: TPU: Uncert: TPU: 2.90 U Uncert: TPU: U 0.00602+/-0.00554

+/-0.00554 pCilg pCilg pCilg 83 (75%-125%)

10/11/06 22:26 10/12/06 10:14 10/11/06 22:26 10/12/06 10:10 0.00169+/-0.00745

+/-0.00745 2.46+/-0.162+/-0.172 85 (75%-125%)

U 0.349 Uncert: +/-0.252 TPU: +/-0.253 U 0.255+/-0.241+/-0.242 11.6+/-0.477+/-0.554 pCi/g 0 (0% -100%) EGDI 12.7 Uncert: TPU: pCi/g 91 (75%-125%)

10/11/06 15:44 10/11/06 16:23 10/11/06 15:23 U -0.0189 pCi/g 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 576582 Uncert: TPU: QC1201201416 173434001 MS Technetium-99 13.0 U Uncert: TPU: 0.349+/-0.252+/-0.253 Batch 576967 QC1201202289 173329001 DUP Iron-55 QC1201202291 LCS Iron-55 QC1201202288 MB lron-55 QC1201202290 173329001 MS Iron-55+/-0.187+/-0.187 12.2+/-0.529+/-0.606 37.8+/-25.9+/-26.1 607+/-42.6+/-61.1 pCi/g 94 (75%-125%)

10/11/06 16:05 U 25.4 Uncert: +/-27.4 TPU: +/-27.4 pCi/g 39 (0% -100%) \4XP1 603 Uncert: TPU: Uncert: TPU: 619 U Uncert: TPU: U 7.46+-/-24.7+/-24.8 pCi/g pCi/g 101 (75%-125%)

10/10/06 23:44 10/11/06 00:17 10/10/06 23:28 10/11/06 00:00 Batch 576968 25.4+/-27.4+/-27.4 64.1+/-13.3+/-13.5 QC1201202293 173329001 DUP Nickel-63 QC1201202295 LCS Nickel-63 QC1201202292 MB Nickel-63 QC1201202294 173329001 MS Nickel-63 549+/-41.6+/-57.4 53.1+/-12.0+/-12.2 462+/-18.0+/-24.0 89 (75%-125%)

pCi/g 0 (0% -100%) \4XPI Uncert: TPU: 503 Uncert: TPU: Uncert: TPU: 503 Uncert: TPU: U 1.69+/-10.1+/-10.1 pCi/g pCi/g pCi/g 92 (75%-125%)

10/11/06 16:48 10/11/06 17:31 10/11/06 16:27 10/11/06 17:10 64.1+/-13.3+/-13.5 523+/-23.1+/-29.2 91 (75%-125%)

Batch 576969 QC1201202297 173435001 DUP Tritium U 3.10 Uncert: +/-5.93 TPU: +/-5.93 U 4.37+/-6.75+/-6.75 pCi/g 0 (0% -100%) DFA I 10/10/06 08:45 10/12/06 02:55 QC1201202299 LCS Tritium 67.6 Uncert: TPU: 56.2+/-9.27+/-9.32 pCi/g 83 (75%-125%)

37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Liquid Scintillation Batch 576969 QC1201202296 MB Tritium Uncert: TPU: U 0.850+/-6.34+/-6.34 pCi/g pCi/g 10/10/06 08:23 10/10/06 09:07 QC1201202298 173435001 MS Tritium 58.4 U Uncert: TPU: 3.10+/-5.93+/-5.93 Batch 578362 QC1201205174 173435001 DUP Carbon- 14 QC1201205176 LCS Carbon- 14 QC1201205173 MB Carbon- 14 QC1201205175 173435001 MS Carbon- 14 U 0.0477 Uncert: +/-0.111 TPU: +/-0.111 U 63.3+/-8.68+/-8.74-0.118+/-0.110+/-0.110 8.66+/-0.265+/-0.297 pCi/g 0 (0% -100%) ALXD2 10/13/06 22:26 108 (75%-125%)

7.27 Uncert: TPU: Uncert: TPU: 7.10 U Uncert: TPU: U -0.0701+/-0.113+/-0.113 pCi/g pCi/g pCi/g 119 (75%-125%)

116 (75%-125%)

10/14/06 00:00 10/13/06 21:38 10/13/06 23:13 0.0477+/-0.111+/-0.111 8.27+/-0.257+/-0.287 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173435 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.39 CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

PRELIMINARY DATA REVIEW FORM Survey Unit: 9520-0003 Survey Unit Name: Southwest Site Storage area Classification

2 Survey Media: Soil Type of Survey : Final Status Survey Type of Measurement:

Radionuclide Specific[umber of Measurements

15 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Target Level (pCi/g): 5.38E+00 2.59E+00 Minimum Value : 2.45E-02 -2.5 1E-02 Maximum Value: 1.99E-01 2.14E-01 Mean : 9.32E-02 2.13E-02 Median: 6.53E-02 1.33E-02 Standard Deviation
5.88E-02 5.50E-02 Sample Identification (1)9520-0003-001F 9520-0003-003F 9520-0003-004F 9520-0003-005F 9520-0003-006F 9520-0003-007F 9520-0003-008F 9520-0003-009F 9520-0003-01OF 9520-0003-01IF 9520-0003-012F 9520-0003-013F 9520-0003-014F 9520-0003-015F 9520-0003-039F Reported Results Cs-137 Concentration (pCi/g)1.58E-01 5.54E-02 2.45E-02 1.07E-01 6.53E-02 1.37E-01 1.99E-01 1.71E-01 4.59E-02 5.77E-02 2.75E-02 2.80E-02 1.14E-01 1.55E-01 5.30E-02 Detect?+++++++++++++Co-60 Concentration (pCi/g)2.14E-01 1.42E-02 1.33E-02 1.78E-02 1.94E-02-4.29E-03 5.69E-03-5.58E-03 2.48E-02 1.51 E-02 6.71E-03-8.93E-03 1.97E-02 1.22E-02-2.51E-02 Fraction of Detect? Target Level+ 0.112 0.016 0.010 0.027+ 0.020 0.025 0.039 0.032+ 0.018 0.017 0.008 0.005 0.029 0.034 0.010 (1) Sample 9520-0003-039F replaced 9520-0003-002F under an addendum to the FSS plan Submitted by/Date)1o1 1 of 1 CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: Survey Unit Name: Mean: 9520-0003 Southwest Site Storage Area 9.32E-02 pCi/g Frequency Plot For Cs-137 10 8 U-2 2.45E-02 7.43E-02 1.24E-01 1.74E-01 2.24E-01 Upper End Value (pCilg)Upper End Observation Observation Value Frequency Frequency 2.45E-02 1 7%7.43E-02 7 47%1.24E-01 2 13%1.74E-01 4 27%2.24E-01 1 7%Total: 15 100%I;;ki~t Submitted by/Date'Review by/Dat 11/17,16o I 1 1 of 1 QUANTILE PLOT FOR CESIUM-137 Survey Unit: 9520-0003 Survey Unit Name: Southwest Site Storage Area Mean: 9.32E-02 pCi/g Quantile Plot For Cs-137 2.50E-01 2.00E-01 ---CL 1.50E-01 ] [1.00E-01 []4)0 S5.O0E-02 I _.OO0E+00 0 20 40 60 80 100 Percentage Cs-137 Rank Percentage 2.45E-02 1 3%2.75E-02 2 10%2.80E-02 3 17%4.59E-02 4 23%5.30E-02 5 30%5.54E-02 6 37%5.77E-02 7 43%6.53E-02 8 50%1.07E-01 9 57%1.14E-01 10 63%1.37E-01 11 70%1.55E-01 12 77%1.58E-01 13 83%1.71E-01 14 90%1.99E-01 15 97%61Lýr,0(k- -,6,f 1"4 Submitted by/Date' .0 CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001, Rev. CY-001 MAJOR Attachment B Sign Test Calculation Sheet For Multiple Radionuclides Survey Area Number: 9520 Survey Unit Number: 0003 Survey Area Name: Southwest Site Storage area WPIR#: 2006-008 Classification:

2 TYPE I (cc error): 0.05 (N): 15 Radionuclides:

Cs-137 Co-60 DCGL: 5.38 pCi/g 2.59 pCi/g Results 1st Results 2"d Weighted Sum 1 -W, Sign Radionuclide Radionuclide (WS)(pCi/g) (pCi/g)1.58E-01 2.14E-01 1.12E-01 8.88E-01 I 5.54E-02 1.42E-02 1.58E-02 9.84E-01 I 2.45E-02 1.33E-02 9.69E-03 9.90E-01 I 1.07E-01 I .78E-02 2.68E-02 9.73E-01 I 6.53E-02 1.94E-02 1.96E-02 9.80E-01 1 1.37E-01 -4.29E-03 2.38E-02 9.76E-01 1 1.99E-01 5.69E-03 3.92E-02 9.61E-01 I 1.71E-01 -5.58E-03 2.96E-02 9.70E-01 I 4.59E-02 2.48E-02 1.81 E-02 9.82E-01 I 5.77E-02 1.51E-02 1.66E-02 9.83E-01 1 2.75E-02 6.71 E-03 7.70E-03 9.92E-01 1 2.80E-02 -8.93E-03 1.76E-03 9.98E-01 I 1.14E-0I 1.97E-02 2.88E-02 9.71E-01 1 1.55E-01 1.22E-02 3.35E-02 9.66E-0I I 5.30E-02 -2.51 E-02 1.60E-04 1.00E+00 I Number of positive differences (S+): 15 Critical Value: 11 Performed by: 37ce We,4e1 (5 ,h Independent Review b Survey Unit Meets Acceptance Criterion Date: /,/"'?/o(, Date: I' CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 1 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9520 Survey Unit #: 0003 Survey Unit name: Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 SML#: 9520-0003-004 Sample

Description:

Comparison of split samples collected from sample measurement location #4 and analyzed using gamma spectroscopy by off-site Vendor Laboratory.

The standard sample was 9520-0003-004F, the comparison sample was 9520-0003-004FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)K-40 10.7 4.5E-1 24 0.75 -1.33 10.6 4.2E-1 0.99 Y 4 4 4- F F 4 4 4 + + F F -F 4- 4+ i + F F + + 4 F +/- ________________________

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.Resolution 4-7 8-15 16 -50 51 -200>200 Agreement Range 0.5 -2.0 0.6 -1.66 0.75 -1.33 0.80 -1.25 0.85- 1.18 (5ý7 Page 1 of 1 Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPyisPoeue22500GPGG-512-0-e.YO0Atcmn Split Sample Assessment Form Survey Area#: 9520 Survey Unit #: 0003 Survey Unit name: Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 SML#: 9520-0003-014 Sample

Description:

Comparison of split samples collected from sample measurement location #14 and analyzed using gamma spectroscopy by off-site Vendor Laboratory.

The standard sample was 9520-0003-014F, the comparison sample was 9520-0003-014FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y6N)K-40 11.8 4.68E-1 25 0.75- 1.33 13.9 6.5E-1 1.12 Y Comments/Corrective Actions: Cs-137 was not detected in one of the field split results Table is provided to show acceptance criteria used to assess split samples.Resolution 4-7 8-15 16-50 51 -200>200 Agreement Range 0.5 -2.0 0.6 -1.66 0.75 -1.33 0.80 -1.25 0.85 -1.18 61--Page 1 of 1 CENTRAL PENINSULA SURVEY UNIT 9520-0003 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9520-0003 FSS McCarthy )Southwest Site rage 1 15 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve--. 1 0.9 ,0.70.6 i 0.5 S0.4 0.3: 0.2 0.1-0._________

___________

I __________

_______ _________

.1*_________

________ -I ________0.0 0.2 04 0.6 0.8 1.0 Unity Rule Sum-of-Ratios, uicluding backgrluxd

--Prospective Power U 1-beta ....Actual Power-LBGR --Estimated Power , DCGL -- -Retrospective Power 1.2 COMPASS v0.0.0 11/I14/2006 Page 1 DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9520-0003-001 F 9520-0003-003F 9520-0003-004F 9520-0003-005F 9520-0003-006F 9520-0003-007F 9520-0003-008F 9520-0003-009F 9520-0003-01 OF 9520-0003-011 F 9520-0003-012F 9520-0003-013F 9520-0003-014F 9520-0003-015F 9520-0003-039F Type S S S S S S S S S S S S S S S Co-60 (pCi/g)0.21 0.01 0.01 0.02 0.02 0 0.01-0.01 0.02 0.02 0.01-0.01 0.02 0.01-0.03 Cs-1 37 (pCi/g)0.16 0.06 0.02 0.11 0.07 0.14 0.2 0.17 0.05 0.06 0.03 0.03 0.11 0.16 0.05 Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9520-0003-001 F 9520-0003-003F 9520-0003-004F 9520-0003-005F 9520-0003-006F 9520-0003-007F 9520-0003-008F 9520-0003-009F 9520-0003-01OF 9520-0003-011 F 9520-0003-012F 9520-0003-013F 9520-0003-014F 9520-0003-015F 9520-0003-039F Type S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0.11 0.02 0.01 0.03 0.02 0.02 0.04 0.03 0.02 0.02 0.01 0 0.03 0.03 0 COMPASS vl.0.0 11/14/2006 Page 2 VU DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=15 Mean (SOR) 0.03 N/A 0.02 Median (SOR) 0.02 N/A N/A Std Dev (SOR) 0.03 N/A 0.02 High Value (SOR) 0.11 N/A N/A Low Value (SOR) 0.00 N/A N/A COMPASS vl.0.0 11114/2006 Page 3