ML13072A036

From kanterella
Revision as of 20:17, 22 March 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search

Nine Mile Point Unit 2, MF0587 - E-mail to Licensee Submission of Analyses Using Prime Code in LAR Regarding Mella+, Reference: Category 1, Pre-Submission Public Meeting - License Amendment Request Regarding Mella
ML13072A036
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 03/12/2013
From: Bhalchandra Vaidya
Plant Licensing Branch 1
To: Darling T H, Dosa J J, Vandeputte D E
Nine Mile Point
References
TAC MF0587
Download: ML13072A036 (1)


Text

Vaidya, BhalchandraFrom: Vaidya, BhalchandraSent: Tuesday, March 12, 2013 1:42 PMTo: 'Dosa, John J'; 'Darling, Theresa H'; 'Vandeputte, Dennis E'; 'Kristensen, Kenneth J'Cc: Jackson, Christopher; Miranda, Samuel; Woodyatt, Diana; Guzzetta, Ashley; Huang, Tai;Panicker, Mathew; Karipineni, Nageswara; Wen, Peter; Meighan, SeanSubject: February 27, 2013, Pre-submittal Category 1, Public Meeting Re: License AmendmentRequest on MELLLA+John, Theresa, Dennis, and Ken,Although not specifically discussed in detail, during the Pre-submittal Category 1, Public Meeting Re: License Amendment Request(LAR) on MELLLA+ on February 27, 2013, US. Nuclear Regulatory Commission (NRC) staff has noted the following:During the pre-application presentation on February 27, 2013, the licensee indicated that their ECCS analyses would be submittedwithout adequately accounting for nuclear fuel thermal conductivity degradation (Slide 9 from the presentation). Specifically, theECCS evaluation would use the GESTR-M fuel thermal performance code. The NRC staff determined that this is a significant,obvious problem for two reasons:1. Condition/Limitation 12 of NEDC-33173(P)(A), "Applicability of General Electric Methods to Expanded Operating Domain,"July 21, 2009, states that,In MFN 06-481, GE committed to submit plenum fission gas and fuel exposure gamma scans as part of therevision to the T-M licensing process. The conclusions of the plenum fission gas and fuel exposure gammascans of GE 10x10 fuel designs as operated will be submitted for NRC staff review and approval. This revisionwill be accomplished through Amendment to GESTAR II or in a T-M licensing LTR. PRIME (a newly developedT-M code) has been submitted to the NRC staff for review (Reference 58). Once the PRIME LTR and itsapplication are approved, future license applications for EPU and MELLLA+ referencing LTR NEDC-33173Pmust utilize the PRIME T-M methods.The PRIME LTR was approved on January 22, 2010.2. NRC Information Notice (IN) 2009-23, "Nuclear Fuel Thermal Conductivity Degradation," notified licensee that analysesperformed using pre-1999 methods may be less conservative than previously understood. In addition, NRC IN 2011-21,"Realistic Emergency Core Cooling System Evaluation Model Effects Resulting from Nuclear Fuel Thermal ConductivityDegradation," notifies addresses that the impact of irradiation on fuel thermal conductivity has the potential to cause errorsin ECCS evaluation models, specifically a higher peak cladding temperature.The information provided by the licensee would contain a significant, obvious problem with the ECCS analyses and it is the staffspolicy that this application would contain insufficient information and would therefore, be considered unacceptable for review.Please address this issue while preparing the LAR.Please let me know immediately, if the licensee would like to have another Category 1, Public Tele-Conference or Meeting to discussthis issue with the NRC staff.This e-mail will be added to ADAMS as a "Publicly Available, Non Sensitive document.Bhalchandra K. VaidyaLicensing Project ManagerNRC/NRR/DORL/LPL1-1(301)-415-3308 (0)bhalchandra.vaidya(anrc.povI