From:

Mahoney, Michael Sent:

Wednesday, January 6, 2021 12:21 PM To:

Cox, Lee

Subject:

State Notification of Amendment to Shearon Harris Nuclear Power Plant, Unit 1 - Revise TS 3/4.4.9, Pressure/Temperature Limits - Reactor Coolant System Attachments:

2020-18120 (FR Notice).pdf Hello Mr. Cox, We are near completion of an amendment for the Shearon Harris Nuclear Power Plant, Unit 1, to revise Technical Specification (TS) 3/4.4.9, Pressure/Temperature Limits - Reactor Coolant System, to reflect an update to the pressure and temperature limit curves in TS Figures 3.4-2, Reactor Coolant System Cooldown Limitations and 3.4-3, Reactor Coolant System Heatup Limitations. The amendment also reflects that the revised pressure and temperature limit curves in TS Figures 3.4-2 and 3.4-3 will be applicable until 55 effective full power years (EFPY) and revises TS Figure 3.4-4, Maximum Allowed PORV Setpoint for the Low Temperature Overpressure Protection System, to reflect that the setpoint values are based on 55 EFPY reactor vessel data.

The application is dated May 12, 2020 as supplemented by letter dated October 1, 2020, (ADAMS Accession Nos. ML20134H888 and ML20275A241, respectively).

The no significant hazards consideration determination was noticed in the Federal Register on August 25, 2020 (85 FR 52380), attached.

Please respond if you have any or no comments.

Thanks Mike Mahoney Project Manager, LPL2-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Desk: (301)-415-3867 Mobile: (301)-250-0450 Email: Michael.Mahoney@nrc.gov

Hearing Identifier:

NRR_DRMA Email Number:

955 Mail Envelope Properties (MN2PR09MB55316EEBEEC2FCAC79BF3E0FE5D00)

Subject:

State Notification of Amendment to Shearon Harris Nuclear Power Plant, Unit 1 -

Revise TS 3/4.4.9, Pressure/Temperature Limits - Reactor Coolant System Sent Date:

1/6/2021 12:21:17 PM Received Date:

1/6/2021 12:21:21 PM From:

Mahoney, Michael Created By:

Michael.Mahoney@nrc.gov Recipients:

"Cox, Lee" <lee.cox@dhhs.nc.gov>

Tracking Status: None Post Office:

MN2PR09MB5531.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1350 1/6/2021 12:21:21 PM 2020-18120 (FR Notice).pdf 91406 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

52370 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices NUCLEAR REGULATORY COMMISSION

[NRC-2020-0187]

Biweekly Notice; Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations AGENCY: Nuclear Regulatory Commission.

ACTION: Biweekly notice.

SUMMARY

Pursuant to section 189.a.(2) of the Atomic Energy Act of 1954, as amended (the Act), the U.S. Nuclear Regulatory Commission (NRC) is publishing this regular biweekly notice.

The Act requires the Commission to publish notice of any amendments issued, or proposed to be issued, and grants the Commission the authority to issue and make immediately effective any amendment to an operating license or combined license, as applicable, upon a determination by the Commission that such amendment involves no significant hazards consideration (NSHC), notwithstanding the pendency before the Commission of a request for a hearing from any person.

This biweekly notice includes all amendments issued, or proposed to be issued, from July 28, 2020, to August 10, 2020. The last biweekly notice was published on August 11, 2020.

DATES: Comments must be filed by September 24, 2020. A request for a hearing or petitions for leave to intervene must be filed by October 26, 2020.

ADDRESSES: You may submit comments by any of the following methods:

  • Federal Rulemaking website: Go to https://www.regulations.gov and search for Docket ID NRC-2020-187. Address questions about NRC Docket IDs in Regulations.gov to Jennifer Borges; telephone: 301-287-9127; email:

Jennifer.Borges@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document.

  • Mail comments to: Office of Administration, Mail Stop: TWFN A60M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, ATTN: Program Management, Announcements and Editing Staff.

For additional direction on obtaining information and submitting comments, see Obtaining Information and Submitting Comments in the SUPPLEMENTARY INFORMATION section of this document.

FOR FURTHER INFORMATION CONTACT:

Janet Burkhardt, Office of Nuclear Reactor Regulation, telephone: 301-415-1384, email: Janet.Burkhardt@

nrc.gov, U.S. Nuclear Regulatory Commission, Washington DC 20555-0001.

SUPPLEMENTARY INFORMATION:

I. Obtaining Information and Submitting Comments A. Obtaining Information Please refer to Docket ID NRC-2020-0187, facility name, unit number(s),

docket number(s), application date, and subject when contacting the NRC about the availability of information for this action. You may obtain publicly-available information related to this action by any of the following methods:

adams.html. To begin the search, select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room reference staff at 1-800-397-4209, 301-415-4737, or by email to pdr.resource@

nrc.gov. The ADAMS accession number for each document referenced (if it is available in ADAMS) is provided the first time that it is mentioned in this document.

B. Submitting Comments Please include Docket ID NRC-2020-0187, facility name, unit number(s),

docket number(s), application date, and subject, in your comment submission.

The NRC cautions you not to include identifying or contact information that you do not want to be publicly disclosed in your comment submission.

The NRC will post all comment submissions at https://

www.regulations.gov as well as enter the comment submissions into ADAMS.

The NRC does not routinely edit comment submissions to remove identifying or contact information.

If you are requesting or aggregating comments from other persons for submission to the NRC, then you should inform those persons not to include identifying or contact information that they do not want to be publicly disclosed in their comment submission.

Your request should state that the NRC does not routinely edit comment submissions to remove such information before making the comment submissions available to the public or entering the comment into ADAMS.

II. Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Combined Licenses and Proposed No Significant Hazards Consideration Determination For the facility-specific amendment requests shown below, the Commission finds that the licensees analyses provided, consistent with title 10 of the Code of Federal Regulations (10 CFR) section 50.91, is sufficient to support the proposed determination that these amendment requests involve NSHC.

Under the Commissions regulations in 10 CFR 50.92, operation of the facility in accordance with the proposed amendment would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety.

The Commission is seeking public comments on this proposed determination. Any comments received within 30 days after the date of publication of this notice will be considered in making any final determination.

Normally, the Commission will not issue the amendment until the expiration of 60 days after the date of publication of this notice. The Commission may issue the license amendment before expiration of the 60-day period provided that its final determination is that the amendment involves NSHC. In addition, the Commission may issue the amendment prior to the expiration of the 30-day comment period if circumstances change during the 30-day comment period such that failure to act in a timely way would result, for example in derating or shutdown of the facility. If the Commission takes action prior to the expiration of either the comment period or the notice period, it will publish in the Federal Register a notice of issuance. If the Commission makes a final NSHC determination, any hearing will take place after issuance. The Commission expects that the need to take action on an amendment before 60 days have elapsed will occur very infrequently.

A. Opportunity To Request a Hearing and Petition for Leave To Intervene Within 60 days after the date of publication of this notice, any persons (petitioner) whose interest may be affected by this action may file a request for a hearing and petition for leave to intervene (petition) with respect to the action. Petitions shall be filed in VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00071 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52371 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices accordance with the Commissions Agency Rules of Practice and Procedure in 10 CFR part 2. Interested persons should consult a current copy of 10 CFR 2.309. The NRCs regulations are accessible electronically from the NRC Library on the NRCs website at https://www.nrc.gov/reading-rm/doc-collections/cfr/. If a petition is filed, the Commission or a presiding officer will rule on the petition and, if appropriate, a notice of a hearing will be issued.

As required by 10 CFR 2.309(d) the petition should specifically explain the reasons why intervention should be permitted with particular reference to the following general requirements for standing: (1) The name, address, and telephone number of the petitioner; (2) the nature of the petitioners right to be made a party to the proceeding; (3) the nature and extent of the petitioners property, financial, or other interest in the proceeding; and (4) the possible effect of any decision or order which may be entered in the proceeding on the petitioners interest.

In accordance with 10 CFR 2.309(f),

the petition must also set forth the specific contentions which the petitioner seeks to have litigated in the proceeding. Each contention must consist of a specific statement of the issue of law or fact to be raised or controverted. In addition, the petitioner must provide a brief explanation of the bases for the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing. The petitioner must also provide references to the specific sources and documents on which the petitioner intends to rely to support its position on the issue. The petition must include sufficient information to show that a genuine dispute exists with the applicant or licensee on a material issue of law or fact. Contentions must be limited to matters within the scope of the proceeding. The contention must be one which, if proven, would entitle the petitioner to relief. A petitioner who fails to satisfy the requirements at 10 CFR 2.309(f) with respect to at least one contention will not be permitted to participate as a party.

Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene. Parties have the opportunity to participate fully in the conduct of the hearing with respect to resolution of that partys admitted contentions, including the opportunity to present evidence, consistent with the NRCs regulations, policies, and procedures.

Petitions must be filed no later than 60 days from the date of publication of this notice. Petitions and motions for leave to file new or amended contentions that are filed after the deadline will not be entertained absent a determination by the presiding officer that the filing demonstrates good cause by satisfying the three factors in 10 CFR 2.309(c)(1)(i) through (iii). The petition must be filed in accordance with the filing instructions in the Electronic Submissions (E-Filing) section of this document.

If a hearing is requested, and the Commission has not made a final determination on the issue of no significant hazards consideration, the Commission will make a final determination on the issue of no significant hazards consideration. The final determination will serve to establish when the hearing is held. If the final determination is that the amendment request involves no significant hazards consideration, the Commission may issue the amendment and make it immediately effective, notwithstanding the request for a hearing. Any hearing would take place after issuance of the amendment. If the final determination is that the amendment request involves a significant hazards consideration, then any hearing held would take place before the issuance of the amendment unless the Commission finds an imminent danger to the health or safety of the public, in which case it will issue an appropriate order or rule under 10 CFR part 2.

A State, local governmental body, Federally-recognized Indian Tribe, or agency thereof, may submit a petition to the Commission to participate as a party under 10 CFR 2.309(h)(1). The petition should state the nature and extent of the petitioners interest in the proceeding.

The petition should be submitted to the Commission no later than 60 days from the date of publication of this notice.

The petition must be filed in accordance with the filing instructions in the Electronic Submissions (E-Filing) section of this document, and should meet the requirements for petitions set forth in this section, except that under 10 CFR 2.309(h)(2) a State, local governmental body, or Federally-recognized Indian Tribe, or agency thereof does not need to address the standing requirements in 10 CFR 2.309(d) if the facility is located within its boundaries. Alternatively, a State, local governmental body, Federally-recognized Indian Tribe, or agency thereof may participate as a non-party under 10 CFR 2.315(c).

If a hearing is granted, any person who is not a party to the proceeding and is not affiliated with or represented by a party may, at the discretion of the presiding officer, be permitted to make a limited appearance pursuant to the provisions of 10 CFR 2.315(a). A person making a limited appearance may make an oral or written statement of his or her position on the issues but may not otherwise participate in the proceeding.

A limited appearance may be made at any session of the hearing or at any prehearing conference, subject to the limits and conditions as may be imposed by the presiding officer. Details regarding the opportunity to make a limited appearance will be provided by the presiding officer if such sessions are scheduled.

B. Electronic Submissions (E-Filing)

All documents filed in NRC adjudicatory proceedings, including a request for hearing and petition for leave to intervene (petition), any motion or other document filed in the proceeding prior to the submission of a request for hearing or petition to intervene, and documents filed by interested governmental entities that request to participate under 10 CFR 2.315(c), must be filed in accordance with the NRCs E-Filing rule (72 FR 49139; August 28, 2007, as amended at 77 FR 46562; August 3, 2012). The E-Filing process requires participants to submit and serve all adjudicatory documents over the internet, or in some cases to mail copies on electronic storage media. Detailed guidance on making electronic submissions may be found in the Guidance for Electronic Submissions to the NRC and on the NRC website at https://www.nrc.gov/site-help/e-submittals.html. Participants may not submit paper copies of their filings unless they seek an exemption in accordance with the procedures described below.

To comply with the procedural requirements of E-Filing, at least 10 days prior to the filing deadline, the participant should contact the Office of the Secretary by email at hearing.docket@nrc.gov, or by telephone at 301-415-1677, to (1) request a digital identification (ID) certificate, which allows the participant (or its counsel or representative) to digitally sign submissions and access the E-Filing system for any proceeding in which it is participating; and (2) advise the Secretary that the participant will be submitting a petition or other adjudicatory document (even in instances in which the participant, or its counsel or representative, already holds an NRC-issued digital ID certificate).

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00072 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52372 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices Based upon this information, the Secretary will establish an electronic docket for the hearing in this proceeding if the Secretary has not already established an electronic docket.

Information about applying for a digital ID certificate is available on the NRCs public website at https://

www.nrc.gov/site-help/e-submittals/

getting-started.html. Once a participant has obtained a digital ID certificate and a docket has been created, the participant can then submit adjudicatory documents. Submissions must be in Portable Document Format (PDF). Additional guidance on PDF submissions is available on the NRCs public website at https://www.nrc.gov/

site-help/electronic-sub-ref-mat.html. A filing is considered complete at the time the document is submitted through the NRCs E-Filing system. To be timely, an electronic filing must be submitted to the E-Filing system no later than 11:59 p.m. Eastern Time on the due date.

Upon receipt of a transmission, the E-Filing system time-stamps the document and sends the submitter an email notice confirming receipt of the document. The E-Filing system also distributes an email notice that provides access to the document to the NRCs Office of the General Counsel and any others who have advised the Office of the Secretary that they wish to participate in the proceeding, so that the filer need not serve the document on those participants separately. Therefore, applicants and other participants (or their counsel or representative) must apply for and receive a digital ID certificate before adjudicatory documents are filed so that they can obtain access to the documents via the E-Filing system.

A person filing electronically using the NRCs adjudicatory E-Filing system may seek assistance by contacting the NRCs Electronic Filing Help Desk through the Contact Us link located on the NRCs public website at https://

www.nrc.gov/site-help/e-submittals.html, by email to MSHD.Resource@nrc.gov, or by a toll-free call at 1-866-672-7640. The NRC Electronic Filing Help Desk is available between 9 a.m. and 6 p.m., Eastern Time, Monday through Friday, excluding government holidays.

Participants who believe that they have a good cause for not submitting documents electronically must file an exemption request, in accordance with 10 CFR 2.302(g), with their initial paper filing stating why there is good cause for not filing electronically and requesting authorization to continue to submit documents in paper format. Such filings must be submitted by: (1) First class mail addressed to the Office of the Secretary of the Commission, U.S.

Nuclear Regulatory Commission, Washington, DC 20555-0001, Attention:

Rulemaking and Adjudications Staff; or (2) courier, express mail, or expedited delivery service to the Office of the Secretary, 11555 Rockville Pike, Rockville, Maryland 20852, Attention:

Rulemaking and Adjudications Staff.

Participants filing adjudicatory documents in this manner are responsible for serving the document on all other participants. Filing is considered complete by first-class mail as of the time of deposit in the mail, or by courier, express mail, or expedited delivery service upon depositing the document with the provider of the service. A presiding officer, having granted an exemption request from using E-Filing, may require a participant or party to use E-Filing if the presiding officer subsequently determines that the reason for granting the exemption from use of E-Filing no longer exists.

Documents submitted in adjudicatory proceedings will appear in the NRCs electronic hearing docket which is available to the public at https://

adams.nrc.gov/ehd, unless excluded pursuant to an order of the Commission or the presiding officer. If you do not have an NRC-issued digital ID certificate as described above, click cancel when the link requests certificates and you will be automatically directed to the NRCs electronic hearing dockets where you will be able to access any publicly available documents in a particular hearing docket. Participants are requested not to include personal privacy information, such as social security numbers, home addresses, or personal phone numbers in their filings, unless an NRC regulation or other law requires submission of such information. For example, in some instances, individuals provide home addresses in order to demonstrate proximity to a facility or site. With respect to copyrighted works, except for limited excerpts that serve the purpose of the adjudicatory filings and would constitute a Fair Use application, participants are requested not to include copyrighted materials in their submission.

The table below provides the plant name, docket number, date of application, ADAMS accession number, and location in the application of the licensees proposed NSHC determination. For further details with respect to these license amendment applications, see the application for amendment which is available for public inspection in ADAMS. For additional direction on accessing information related to this document, see the Obtaining Information and Submitting Comments section of this document.

Arizona Public Service Company, et al; Palo Verde Nuclear Generating Station,Units 1, 2, and 3; Maricopa County, AZ Docket Nos...............................................................................................

50-528, 50-529, 50-530.

Application Date.......................................................................................

July 1, 2020.

ADAMS Accession No. of Application......................................................

ML20183A460.

Location in Application of NSHC..............................................................

Pages 2 and 3 of the Enclosure.

Brief Description of Amendments.............................................................

The proposed amendment would revise Technical Specifications (TSs) in accordance with Technical Specifications Task Force (TSTF) Trav-eler TSTF-563, Revision 0, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program, dated May 10, 2017 (ADAMS Accession No. ML17130A819). TSTF-563 revises the TS definitions of Channel Calibration and Channel Func-tional Test, which currently permit performance by any series of se-quential, overlapping, or total channel steps, to allow the required frequency for testing the components or devices in each step to be determined in accordance with the TS Surveillance Frequency Con-trol Program. The NRC issued a final safety evaluation approving TSTF-563, Revision 0, on December 4, 2018 (ADAMS Accession No. ML18333A144).

Proposed Determination...........................................................................

NSHC.

VerDate Sep<11>2014 20:00 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00073 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52373 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices Name of Attorney for Licensee, Mailing Address....................................

Michael G. Green, Associate General Counsel, Nuclear and Environ-mental Pinnacle West Capital Corporation, P.O. Box 52034, MS 7602, Phoenix, AZ 85072-2034.

NRC Project Manager, Telephone Number.............................................

Siva Lingam, 301-415-1564.

DTE Electric Company; Fermi, Unit 2; Monroe County, MI Docket No.................................................................................................

50-341.

Application Date.......................................................................................

June 5, 2020.

ADAMS Accession No. of Application......................................................

ML20157A169.

Location in Application of NSHC..............................................................

Pages 2 and 3 of Enclosure 1.

Brief Description of Amendments.............................................................

The proposed amendment would revise the Technical Specifications to adopt Technical Specifications Task Force (TSTF) Traveler TSTF-563, Revise Instrument Testing Definitions to Incorporate the Sur-veillance Frequency Control Program.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Jon P. Christinidis, DTE Energy, Expert AttorneyRegulatory, 688 WCB, One Energy Plaza, Detroit, MI 48226.

NRC Project Manager, Telephone Number.............................................

Surinder Arora, 301-415-1421.

Duke Energy Progress, LLC; Shearon Harris Nuclear Power Plant, Unit 1; Brunswick County, NC Docket No.................................................................................................

50-400.

Application Date.......................................................................................

March 12, 2020.

ADAMS Accession No. of Application......................................................

ML20072M618.

Location in Application of NSHC..............................................................

Pages 12-15 of Enclosure 1.

Brief Description of Amendments.............................................................

The proposed amendment would revise Technical Specification (TS) 3.3.3.6, Accident Monitoring Instrumentation, to revise the allowed outage times for inoperable post-accident monitoring (PAM) instru-mentation, eliminate the shutdown requirement for inoperable PAM instruments when the minimum required channels are operable, and add a provision that allows a separate action entry for each instru-ment function. The proposed amendment would also revise TS 3.9.2, Instrumentation, to remove the audible indication requirement in Mode 6, as well as relocate the requirements for electrical equipment protective devices in TS 3.8.4.1, Containment Penetration Con-ductor Overcurrent Protective Devices, and TS 3.8.4.2, Motor-Op-erated Valves Thermal Overload Protection, from the TSs to a li-censee-controlled procedure.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

David Cummings, Associate General Counsel, Mail Code DEC45, 550 South Tryon Street, Charlotte NC 28202.

NRC Project Manager, Telephone Number.............................................

Michael Mahoney, 301-415-3867.

Duke Energy Progress, LLC; Shearon Harris Nuclear Power Plant, Unit 1; Brunswick County, NC Docket No.................................................................................................

50-400.

Application Date.......................................................................................

May 12, 2020 ADAMS Accession No. of Application......................................................

ML20134H888.

Location in Application of NSHC..............................................................

Pages 14-16 of Enclosure 1.

Brief Description of Amendments.............................................................

The proposed amendment would revise Technical Specification (TS) 3/

4.4.9, Pressure/Temperature LimitsReactor Coolant System, to reflect an update to the pressure and temperature limit curves in Fig-ures 3.4-2 (Reactor Coolant System Cooldown Limitations) and 3.4-3 (Reactor Coolant System Heatup Limitations). The proposed amendment would also reflect that TS Figures 3.4-2 and 3.4-3 will be applicable until 55 effective full power years (EFPY) and would revise TS Figure 3.4-4 (Maximum Allowed Power Operated Relief Valve Setpoint for the Low Temperature Overpressure Protection System) to reflect that the setpoint values are based on 55 EFPY re-actor vessel data.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

David Cummings, Associate General Counsel, Mail Code DEC45, 550 South Tryon Street, Charlotte NC 28202.

NRC Project Manager, Telephone Number.............................................

Michael Mahoney, 301-415-3867.

Energy Harbor Nuclear Corp. and Energy Harbor Nuclear Generation LLC; Beaver Valley Power Station, Units 1 and 2; Beaver County, PA Docket Nos...............................................................................................

50-334, 50-412.

Application Date.......................................................................................

July 10, 2020.

ADAMS Accession No. of Application......................................................

ML20192A210.

Location in Application of NSHC..............................................................

Pages 3-5 of the Enclosure.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00074 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52374 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices Brief Description of Amendments.............................................................

The proposed amendments would add a new Technical Specification 3.6.9, Containment Sump, and add an action to address the condi-tion of the containment sump made inoperable due to containment accident generated and transported debris exceeding the analyzed limits. The action would provide time to correct or evaluate the condi-tion in lieu of an immediate plant shutdown.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Rick Giannantonio, General Counsel, Energy Harbor Corp., 168 E.

Market Street, Akron, OH 44308-2014.

NRC Project Manager, Telephone Number.............................................

Jennifer Tobin, 301-415-2328.

Energy Harbor Nuclear Corp. and Energy Harbor Nuclear Generation LLC; Beaver Valley Power Station, Units 1 and 2; Beaver County, PA Docket Nos...............................................................................................

50-334, 50-412.

Application Date.......................................................................................

July 13, 2020.

ADAMS Accession No. of Application......................................................

ML20195A845.

Location in Application of NSHC..............................................................

Pages 5 and 6 of the Enclosure.

Brief Description of Amendments.............................................................

The proposed amendments would delete Conditions B and C of the Beaver Valley, Units 1 and 2, Renewed Facility Operating Licenses related to irradiated fuel management plan funding.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Rick Giannantonio, General Counsel, Energy Harbor Corp., 168 E.

Market Street, Akron, OH 44308-2014.

NRC Project Manager, Telephone Number.............................................

Jennifer Tobin, 301-415-2328.

Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Station, Unit 1; Westchester County, NY Docket No.................................................................................................50-003.

Application Date.......................................................................................

June 30, 2020.

ADAMS Accession No. of Application......................................................

ML20182A679.

Location in Application of NSHC..............................................................

Pages 24-26 of the Enclosure.

Brief Description of Amendments.............................................................

The proposed amendment would revise the Indian Point (IP) Unit 1 Provisional Operating License and Technical Specifications in Ap-pendix A to reflect the current conditions at IP Unit 1 and the perma-nent cessation of power operations at IP Unit 2 and to denote that certain IP Unit 1 systems also support IP Unit 3.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Bill Glew, Associate General Counsel, Entergy Services, Inc., 639 Loy-ola Avenue, 22nd Floor, New Orleans, LA 70113.

NRC Project Manager, Telephone Number.............................................

Richard Guzman, 301-415-1030.

Exelon FitzPatrick, LLC and Exelon Generation Company, LLC; James A FitzPatrick Nuclear Power Plant; LLC; Oswego County, NY Docket No.................................................................................................

50-333.

Application Date.......................................................................................

June 30, 2020.

ADAMS Accession No. of Application......................................................

ML20182A198.

Location in Application of NSHC..............................................................

Pages 9 and 10 of Attachment 1.

Brief Description of Amendments.............................................................

The proposed amendment would modify the containment venting flow path in Surveillance Requirement 3.6.1.3.1 of Technical Specification 3.6.1.3, Primary Containment Isolation Valves (PCIVs).

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Donald P. Ferraro, Assistant General Counsel, Exelon Generation Company, LLC, 200 Exelon Way, Suite 305, Kennett Square, PA 19348.

NRC Project Manager, Telephone Number.............................................

Justin Poole, 301-415-2048.

Tennessee Valley Authority; Sequoyah Nuclear Plant, Units 1 and 2; Hamilton County, TN, Tennessee Valley Authority; Watts Bar Nuclear Plant, Units 1 and 2; Rhea County, TN Docket Nos...............................................................................................

50-327, 50-328, 50-390, 50-391.

Application Date.......................................................................................

June 16, 2020.

ADAMS Accession No. of Application......................................................

ML20169A503.

Location in Application of NSHC..............................................................

Pages E2-E4 of the Enclosure.

Brief Description of Amendments.............................................................

The proposed amendments would revise the Technical Specifications (TSs) to adopt Technical Specification Task Force (TSTF) Traveler TSTF-569, Revision 2, Revise Response Time Testing Definition (ADAMS Accession No. ML19176A034).

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Sherry Quirk, Executive VP and General Counsel, Tennessee Valley Authority, 400 West Summit Hill Drive, WT 6A, Knoxville, TN 37902.

NRC Project Manager, Telephone Number.............................................

Michael Wentzel, 301-415-6459.

Tennessee Valley Authority; Watts Bar Nuclear Plant, Unit 1; Rhea County, TN Docket No.................................................................................................

50-390.

Application Date.......................................................................................

June 22, 2020.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00075 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52375 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices ADAMS Accession No. of Application......................................................

ML20174A546.

Location in Application of NSHC..............................................................

Pages E5-E7 of the Enclosure.

Brief Description of Amendments.............................................................

The proposed amendment would revise Watts Bar Nuclear Plant, Unit 1 Technical Specification 3.3.3, Post Accident Monitoring (PAM) In-strumentation, Table 3.3.3-1, to delete the term plasma from the footnotes in the PAM instrumentation table.

Proposed Determination...........................................................................

NSHC.

Name of Attorney for Licensee, Mailing Address....................................

Sherry Quirk, Executive VP and General Counsel, Tennessee Valley Authority, 400 West Summit Hill Drive, WT 6A, Knoxville, TN 37902.

NRC Project Manager, Telephone Number.............................................

Kimberly Green, 301-415-1627.

III. Notice of Issuance of Amendments to Facility Operating Licenses and Combined Licenses During the period since publication of the last biweekly notice, the Commission has issued the following amendments. The Commission has determined for each of these amendments that the application complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commissions rules and regulations.

The Commission has made appropriate findings as required by the Act and the Commissions rules and regulations in 10 CFR chapter I, which are set forth in the license amendment.

A notice of consideration of issuance of amendment to facility operating license or combined license, as applicable, proposed NSHC determination, and opportunity for a hearing in connection with these actions, was published in the Federal Register as indicated.

Unless otherwise indicated, the Commission has determined that these amendments satisfy the criteria for categorical exclusion in accordance with 10 CFR 51.22. Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared for these amendments. If the Commission has prepared an environmental assessment under the special circumstances provision in 10 CFR 51.22(b) and has made a determination based on that assessment, it is so indicated.

For further details with respect to the action, see (1) the application for amendment; (2) the amendment; and (3) the Commissions related letter, Safety Evaluation, and/or Environmental Assessment as indicated. All of these items can be accessed as described in the Obtaining Information and Submitting Comments section of this document.

Arizona Public Service Company, et al; Palo Verde Nuclear Generating Station, Units 1, 2, and 3; Maricopa County, AZ Date Issued..............................................................................................

July 31, 2020.

ADAMS Accession No..............................................................................

ML20163A037.

Amendment Nos.......................................................................................

213 (Unit 1), 213 (Unit 2), and 213 (Unit 3).

Brief Description of Amendments.............................................................

The amendments revised certain emergency response organization (ERO) positions in the Palo Verde Nuclear Generating Station (Palo Verde) Emergency Plan. Specifically, the amendments revised cer-tain ERO positions in accordance with the guidance specified in the Alternative Guidance for Licensee Emergency Response Organiza-tions, finalized in a letter from the NRC to the Nuclear Energy Insti-tute, dated June 12, 2018 (ADAMS Accession No. ML18022A352).

The amendments also relocated the non-minimum staff ERO per-sonnel from the Palo Verde Emergency Plan to emergency pre-paredness implementing procedures. The amendments were re-viewed considering the requirements of 10 CFR 50.47, Emergency plans, paragraph (b) and Appendix E to 10 CFR Part 50, Emer-gency Planning and Preparedness for Production and Utilization Fa-cilities, and the applicable emergency preparedness NRC guidance documents. These requirements and guidance documents establish emergency planning standards that require (1) adequate staffing; (2) satisfactory performance of key functional areas and critical tasks; and (3) timely augmentation of the response capability.

Docket Nos...............................................................................................

50-528, 50-529, 50-530.

Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit 2; New London County, WI Date Issued..............................................................................................

August 7, 2020.

ADAMS Accession No..............................................................................

ML20191A004.

Amendment No.........................................................................................

340.

Brief Description of Amendments.............................................................

The amendment revised the technical specifications by reducing the re-actor coolant system and secondary side specific activity by 50 per-cent.

Docket No.................................................................................................

50-336.

Exelon Generation Company, LLC; Braidwood Station, Units 1 and 2; Will County, IL; Exelon Generation Company, LLC; Byron Sta-tion, Units 1 and 2, Ogle County, IL; Exelon Generation Company, LLC, Clinton Power Station, Unit 1, DeWitt County, IL; Exelon Generation Company, LLC; Dresden Nuclear Power Station, Units 1, 2, and 3; Grundy County, IL; Exelon Generation Company, LLC, LaSalle County Station, Units 1 and 2; LaSalle County, IL; Exelon Generation Company, LLC; Quad Cities Nuclear Power Station, Units 1 and 2; Rock Island County, IL Date Issued..............................................................................................

July 31, 2020.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00076 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52376 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices ADAMS Accession No..............................................................................

ML20153A804.

Amendment Nos.......................................................................................

Braidwood Unit 1 (213), Unit 2 (213); Byron Unit 1 (217), Unit 2 (217);

Clinton Unit 1 (234); Dresden Unit 1 (49), Unit 2 (271), Unit 3 (264);

LaSalle Unit 1 (246), Unit 2 (232); and Quad Cities Unit 1 (284), Unit 2 (280).

Brief Description of Amendments.............................................................

The amendments revised the emergency plan for each site by chang-ing emergency action level RA3 to remove specific references to ra-diation monitoring instrumentation.

Docket Nos...............................................................................................

50-456, 50-457, 72-73, 50-454, 50-455, 72-68, 50-461, 72-1046,50-010, 50-237, 50-249, 72-37, 50-373, 50-374, 72-70, 50-254, 50-265, and 72-53.

Exelon Generation Company, LLC; Limerick Generating Station, Units 1 and 2; Montgomery County, PA Date Issued..............................................................................................

August 7, 2020.

ADAMS Accession No..............................................................................

ML20160A459.

Amendment Nos.......................................................................................

248 (Unit 1) and 210 (Unit 2).

Brief Description of Amendments.............................................................

The amendments revised Technical Specification Surveillance Require-ment 4.0.5, Inservice Inspection and Inservice Testing Program, in accordance with the implementation of a previously approved amendment dated July 31, 2018 (ADAMS Accession No.

ML18165A162), to adopt 10 CFR 50.69, Risk-Informed Categoriza-tion and Treatment of Structures, Systems and Components for Nu-clear Power Reactors.

Docket Nos...............................................................................................

50-352, 50-353 Indiana Michigan Power Company; Donald C. Cook Nuclear Plant, Units 1 and 2; Berrien County, MI Date Issued..............................................................................................

August 7, 2020.

ADAMS Accession No..............................................................................

ML20037A656.

Amendment Nos.......................................................................................

352 (Unit 1) and 333 (Unit 2).

Brief Description of Amendments.............................................................

The amendments revised the Donald C. Cook Nuclear Plant, Unit 1 and 2, technical specifications to adopt Technical Specifications Task Force (TSTF) Traveler TSTF-569, Revise Response Time Testing.

Docket Nos...............................................................................................

50-315, 50-316.

NextEra Energy Duane Arnold, LLC; Duane Arnold Energy Center; Linn County, IA Date Issued..............................................................................................

July 30, 2020.

ADAMS Accession No..............................................................................

ML20184A003.

Amendment No.........................................................................................

312.

Brief Description of Amendments.............................................................

The amendment deleted License Condition 2.C.(3), Fire Protection Program, which requires that the licensee implement and maintain a fire protection program that complies with the requirements of 10 CFR 50.48, paragraphs (a) and (c).

Docket No.................................................................................................

50-331.

PSEG Nuclear LLC; Salem Nuclear Generating Station, Units 1 and 2; Salem County, NJ Date Issued..............................................................................................

August 6, 2020.

ADAMS Accession No..............................................................................

ML20191A203.

Amendment Nos.......................................................................................

335 (Unit 1) and 316 (Unit 2).

Brief Description of Amendments.............................................................

The amendments revised Technical Specification (TS) 34.3.1, Reactor Trip System Instrumentation, Limiting Condition for Operation 3.3.1.1, by modifying the applicable modes and required actions, and TS Table 4.3-1, Reactor Trip System Instrumentation Surveillance Requirements, to align the surveillance requirements.

Docket Nos...............................................................................................

50-272, 50-311.

Virginia Electric and Power Company, Dominion Nuclear Company; North Anna Power Station, Units 1 and 2; Louisa County, VA Date Issued..............................................................................................

January 17, 2020.

ADAMS Accession No..............................................................................

ML19319A583.

Amendment Nos.......................................................................................

285 (Unit 1) and 268 (Unit 2).

Brief Description of Amendments.............................................................

The amendments revised the emergency diesel generator maximum voltage Surveillance Requirement.

Docket Nos...............................................................................................

50-338, 50-339.

Virginia Electric and Power Company; Surry Power Station, Units 1 and 2; Surry County, VA Date Issued..............................................................................................

May 19, 2020.

ADAMS Accession No..............................................................................

ML20085G964.

Amendment Nos.......................................................................................

298 (Unit 1) and 298 (Unit 2).

Brief Description of Amendments.............................................................

The amendments revised the Surry, Units 1 and 2, Technical Speci-fication Table 3.7-1, Reactor Trip Instrument Operating Conditions, to provide a completion time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to restore an inoperable re-actor trip breaker to operable status.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00077 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52377 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices Docket Nos...............................................................................................

50-280, 50-281.

Notice of Issuance of Amendments to Facility Operating Licenses and Combined Licenses and Final Determination of No Significant Hazards Consideration and Opportunity for a Hearing (Exigent Public Announcement or Emergency Circumstances)

During the period since publication of the last biweekly notice, the Commission has issued the following amendments. The Commission has determined for each of these amendments that the application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commissions rules and regulations. The Commission has made appropriate findings as required by the Act and the Commissions rules and regulations in 10 CFR chapter I, which are set forth in the license amendment.

Because of exigent or emergency circumstances associated with the date the amendment was needed, there was not time for the Commission to publish, for public comment before issuance, its usual notice of consideration of issuance of amendment, proposed NSHC determination, and opportunity for a hearing.

For exigent circumstances, the Commission has either issued a Federal Register notice providing opportunity for public comment or has used local media to provide notice to the public in the area surrounding a licensees facility of the licensees application and of the Commissions proposed determination of NSHC. The Commission has provided a reasonable opportunity for the public to comment, using its best efforts to make available to the public means of communication for the public to respond quickly, and in the case of telephone comments, the comments have been recorded or transcribed as appropriate and the licensee has been informed of the public comments.

In circumstances where failure to act in a timely way would have resulted, for example, in derating or shutdown of a nuclear power plant or in prevention of either resumption of operation or of increase in power output up to the plants licensed power level, the Commission may not have had an opportunity to provide for public comment on its NSHC determination. In such case, the license amendment has been issued without opportunity for comment. If there has been some time for public comment but less than 30 days, the Commission may provide an opportunity for public comment. If comments have been requested, it is so stated. In either event, the State has been consulted by telephone whenever possible.

Under its regulations, the Commission may issue and make an amendment immediately effective, notwithstanding the pendency before it of a request for a hearing from any person, in advance of the holding and completion of any required hearing, where it has determined that NSHC is involved.

The Commission has applied the standards of 10 CFR 50.92 and has made a final determination that the amendment involves NSHC. The basis for this determination is contained in the documents related to this action.

Accordingly, the amendments have been issued and made effective as indicated.

Unless otherwise indicated, the Commission has determined that these amendments satisfy the criteria for categorical exclusion in accordance with 10 CFR 51.22. Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared for these amendments. If the Commission has prepared an environmental assessment under the special circumstances provision in 10 CFR 51.12(b) and has made a determination based on that assessment, it is so indicated.

For further details with respect to the action see (1) the application for amendment, (2) the amendment to Facility Operating License or Combined License, as applicable, and (3) the Commissions related letter, Safety Evaluation and/or Environmental Assessment, as indicated. All of these items can be accessed as described in the Obtaining Information and Submitting Comments section of this document.

Virginia Electric and Power Company; Surry Power Station, Units 1 and 2; Surry County, VA Date of Amendment.................................................................................

May 7, 2020.

Brief Description of Amendment..............................................................

The amendments revised the Surry, Units 1 and 2, Technical Speci-fication 6.4.Q.4.b to add a note to permit a one-time deferral of the Surry, Unit 2 Steam Generator B inspection from the spring 2020 refueling outage (RFO) (2R29) to the fall 2021 RFO (2R30).

ADAMS Accession No..............................................................................

ML20115E237.

Amendment Nos.......................................................................................

299 (Unit 1) and 299 (Unit 2).

Public Comments Requested as to Proposed NSHC (Yes/No)..............

Yes.

Docket Nos...............................................................................................

50-280, 50-281.

Previously Published Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Combined Licenses, Proposed No Significant Hazards Consideration Determination, and Opportunity for a Hearing The following notices were previously published as separate individual notices. The notice content was the same as above. They were published as individual notices either because time did not allow the Commission to wait for this biweekly notice or because the action involved exigent circumstances.

They are repeated here because the biweekly notice lists all amendments issued or proposed to be issued involving no significant hazards consideration.

For details, including the applicable notice period, see the individual notice in the Federal Register on the day and page cited.

Union Electric Company; Callaway Plant, Unit 1; Callaway County, MO Application Date.......................................................................................

June 26, 2020.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00078 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES

52378 Federal Register / Vol. 85, No. 165 / Tuesday, August 25, 2020 / Notices ADAMS Accession No..............................................................................

ML20178A668.

Brief Description of Amendment..............................................................

Due to the COVID-19 public health emergency, the proposed one-time amendment would revise Technical Specification 5.5.9, Steam Gen-erator (SG) Program, to defer the SG tube inspection currently scheduled during Refueling Outage (RFO) 24, in the fall of 2020, to RFO 25, scheduled for the spring of 2022.

Date & Cite of Federal Register Individual Notice.................................

July 24, 2020 (85 FR 44936).

Expiration Dates for Public Comments & Hearing Requests..................

August 24, 2020 (public comments); September 22, 2020 (hearing re-quests).

Docket No.................................................................................................

50-483.

Dated: August 13, 2020.

For the Nuclear Regulatory Commission.

Gregory F. Suber, Deputy Director, Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation.

[FR Doc. 2020-18120 Filed 8-24-20; 8:45 am]

BILLING CODE 7590-01-P NUCLEAR REGULATORY COMMISSION

[NRC-2019-0234]

Information Collection: NRC Form 536, Operator Licensing Examination Data AGENCY: Nuclear Regulatory Commission.

ACTION: Notice of submission to the Office of Management and Budget; request for comment.

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) has recently submitted a request for renewal of an existing collection of information to the Office of Management and Budget (OMB) for review. The information collection is entitled, NRC Form 536, Operator Licensing Examination Data.

DATES: Submit comments by September 24, 2020. Comments received after this date will be considered if it is practical to do so, but the Commission is able to ensure consideration only for comments received on or before this date.

ADDRESSES: Written comments and recommendations for the proposed information collection should be sent within 30 days of publication of this notice to https://www.reginfo.gov/

public/do/PRAMain. Find this particular information collection by selecting Currently under Review Open for Public Comments or by using the search function.

FOR FURTHER INFORMATION CONTACT:

David Cullison, NRC Clearance Officer, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone:

301-415-2084; email:

Infocollects.Resource@nrc.gov.

SUPPLEMENTARY INFORMATION:

I. Obtaining Information and Submitting Comments A. Obtaining Information Please refer to Docket ID NRC-2019-0234 when contacting the NRC about the availability of information for this action. You may obtain publicly-available information related to this action by any of the following methods:

adams.html. To begin the search, select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room reference staff at 1-800-397-4209, 301-415-4737, or by email to pdr.resource@

nrc.gov. The supporting statement and NRC Form 536, Operator Licensing Examination Data, are available in ADAMS under Accession Nos.

ML20140A316 and ML20008D415, respectively.

  • NRCs Clearance Officer: A copy of the collection of information and related instructions may be obtained without charge by contacting the NRCs Clearance Officer, David Cullison, Office of the Chief Information Officer, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone:

301-415-2084; email:

Infocollects.Resource@nrc.gov.

B. Submitting Comments The NRC cautions you not to include identifying or contact information in comment submissions that you do not want to be publicly disclosed in your comment submission. All comment submissions are posted at https://

www.regulations.gov and entered into ADAMS. Comment submissions are not routinely edited to remove identifying or contact information.

If you are requesting or aggregating comments from other persons for submission to the OMB, then you should inform those persons not to include identifying or contact information that they do not want to be publicly disclosed in their comment submission. Your request should state that comment submissions are not routinely edited to remove such information before making the comment submissions available to the public or entering the comment into ADAMS.

II. Background Under the provisions of the Paperwork Reduction Act of 1995 (44 U.S.C. Chapter 35), the NRC recently submitted a request for renewal of an existing collection of information to OMB for review entitled, NRC Form 536, Operator Licensing Examination Data. The NRC hereby informs potential respondents that an agency may not conduct or sponsor, and that a person is not required to respond to, a collection of information unless it displays a currently valid OMB control number.

The NRC published a Federal Register notice with a 60-day comment period on this information collection on April 9, 2020 (85 FR 19965).

1. The title of the information collection: NRC Form 536, Operator Licensing Examination Data.
2. OMB approval number: 3150-0131.
3. Type of submission: Extension.
4. The form number if applicable:

536.

5. How often the collection is required or requested: Annually.
6. Who will be required or asked to respond: (a) All holders of operating licenses for nuclear power reactors under the provision of title 10 of the Code of Federal Regulations (10 CFR) part 50, Domestic Licensing of Production and Utilization Facilities, except those that have permanently ceased operations and have certified that fuel has been permanently removed from the reactor vessel, (b) All holders of, or applicants for, a limited work authorization, early site permit, or combined licenses issued under 10 CFR part 52, Licenses, Certifications and Approval for Nuclear Power Plants.

VerDate Sep<11>2014 19:55 Aug 24, 2020 Jkt 250001 PO 00000 Frm 00079 Fmt 4703 Sfmt 4703 E:\\FR\\FM\\25AUN1.SGM 25AUN1 khammond on DSKJM1Z7X2PROD with NOTICES