ML100740159

From kanterella
Revision as of 21:55, 13 November 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Report of Analysis/Certificate of Conformance, L38101
ML100740159
Person / Time
Site: Oyster Creek
Issue date: 04/28/2009
From: Jeter K
Teledyne Brown Engineering, Teledyne Technologies
To: Vouglitois J
Exelon Nuclear, Office of Information Services
References
FOIA/PA-2009-0214
Download: ML100740159 (8)


Text

A*A 6M, TELEDYNE PPN BROWN ENGINEERING, INC.

A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 James J. Vouglitois Exelon Nuclear (Oyster Creek) ~&7?~,o 32~,c1pc(i £2A~i'vK'4c iA~

P.O. Box 388 US Route 9 Forked River, NJ 08731 Report of Analysis/Certificate of Conformance 04/28/2009 LIMS #: L38101 Project 1D# EX00I-3EREMPOC-05 Received: 03/30/2009 Delivery Date 05/04/2009 P.O.#: 01000298 REL.#00010 Release #

3DG#:

This is to certify that Teledyne Brown Engineering - Environmental Services located at 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested and documented samples, as received by the laboratory, as specified in the applicable purchase order.

This also certifies that requirements of applicable codes, standards and specifications have been fully met and that any quality assurance documentation which verified conformance to the purchase order is on file and may be examined upon request.

I hereby certify that the above statements are true and correct.

Keith Jeter Operations Manager Cross Reference Table Client ID Laboratory'I) Station ID (if applicable) 33 L38101-1 33 94 L38101-2 94 I L38101-3 1 37 L38101-4 37 38 L38101-5 38 39 ~L38101-6 3 QCA L38101-7 QCA Page 1 of 8 4'ý

!- BROWN/EN'iGINEERING, INC.

ATeledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 Method Reference Numbers Matrix Analysis Method Reference WD GAMMA EPA 901.1 WD) H-3 (DIST) f EPA 906.0 WT [ GAMMA EPA 901.1 WT H-3 (DIST) EPA 906.0 This report shall not be reproduced or distributed'except in its entirety.

Page 2 of 8

UI1..OIu v,'J4, ATeledyne Technologies Company L38101 Exelon Nuclear (Oyster Creek)

EX001-3EREMPOC-05 Sample ID: 33 Collect Start: 03/05/2009 10:15 Matrix: Surface Water (WT)

Station: 33 Collect Stop: 03/25/2009 10:25 Volume:

Description:

ReceiveDate: 03/30/2009  % Moisture:

LIMS Number: L38101-1 Count C0n j 1op IRun Aiut lqot Rfrne Cnt Radionuclide SO I Activity Conc jUncertainty 2 Sigma MDC j Units, #1 Volume Units Date Date Time j Units Flag Values 4-3(DIST) 2011 T -2.64E+01 1.19E+02 1.98E+02 I pCi/L 1 1 10 J 2 m1 I _ 03/31/09F 80 T M IU I 3E-7 2007 8 .93E+00 1 2.46E+01 4.06E+01 I pCi/L 11 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 See IU I I No I C-40 F 2007 1 2.84E+02 1 4.62E+0l 1 3.00E+01 3 pCi/L 1-1 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 Sec [+ _ I Yes I IN-54 F 2007 1 2.07E+00 2.32E+00 1 3.94E+00 F pCi/L {V7 3502.26" ml 103/25/09 10:25 1 04/08/091 25665 1 See U I No 1 3502.26 1

ý0-58 E-59

.

F 2007 2007 T1 -2.84E+00I

-148E+00I 2.64E+00 I 4.11E+00 I 5:65E+00 1 9.13E+00'E pCi/L pCi/L 1 1 3502.26 1 ml ml 103/25/09 10:25 1 04/08/091 103/25/09 10:25 1 04/081091 25665 25665 1

1 See Sec

[U U r I

_

No No 20-60 F 2007 1 8.76E-0l I 2.34E+000 3.92E+00 r pCi/L 1 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 See I U __ I NoF

,FN-65 1 2007 1 -l.55E+00 5.20E+00 1 8.39E+00 F pCi/L 11 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 Sec IU I I No I B-95 1 2007 1 -6.91E-01 I 2.61E+O0 1 4.22E+00 F pCi/L I I 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 Sec I U I_ I No ER-95 1 2007 1 -2.64E+00.I 4.52E+00 1 7.19E+00 F pCi/L 11 3502.26 1 ml 103/25/09 10:25 1.04/08/091 25665 1 See U FNoF_

I

-131 11 2007 -I-1.22E+00 8.77E+00 1 4.26E+00 1.39E+01 F pCi/L I " 3502.26 11 ml 103/25/09 10:25 1 04/08/091 25665 1 See 25665 1 See IU I FFU I No I S-134 2007 1 4.10E+00 5.57E+000 I pCi/b I I 3502.26 ml 103/25/09 10:25 604/08/09[ No

ýS-137 1 2007 1 2.38E+00 I 2.58E+00 1 4.37E+00 I pCi/L 1.1 3502.26 1 ml 103/25/09 10:25 1 04/08/091 25665 1 See FU __ IN 3A-140 1 2007 1 -3.21E+00 1.83E+01 I 2.97E+01 I pCi/L J 3502.26 1 ml 103/25/09 10:25 1 04/08/091. 25665 1 See [F I No_

LA-140, 2007 4.83E-01 F 5.08E+00 I 8.39E+00 pCi/L I I 3502.26 1 ml 103/25/09 10:25 1 04/08/09 25665 1 See [U __ No_

PA-226 1 2007 5.53E+00 I 7.53E+01 I 1.07E+02 V pCi/L I 3502.26 i ml 103/25/09 10:25 1 04/08/091 25665.1 See FU __ Yes_

TI-232 1 2007 -1.88E+00 9.04E+00 I 1.44E+01 V pCi/L I I 3502.26 I ml 03/25/09 10:25 1 04/08/091 25665 1 See U I_____

Flag Values No =Peak not identifiedin gamma spectrum U = Compound/Analyte not detected or less than 2 sigma

+ = Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum U* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 2 sigma *** Results are reported on an as received basis High = Activity concentration exceeds customer reporting value unless otherwise noted Spec = MDC exceeds customer technical specification L Low recovery MDC - Minimum Detectable Concentration H = High recovery Bolded text indicates reportable value.. PAe I of R

U4LnI. JY  :

.. V)1"j .A Teledyne Technologies Company L38101 Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3EREMPOC-05 Sample ID: 94 Collect Start: 03/05/2009'09:35 Matrix: Surfice Water (WT)

Station: 94 Collect Stop: 03/26/2009 10:15 / Volume:

Description:

Receive Date: 03/30/2009  % Moisture:

LIMS Number: L38101-2 Alqo Alqo Rernc Cut Cut Cut So# Activity UncertaintyRu Volume Units Date

  • Date Time Units Flag Values Radionuclide SOP# Cone 2 Sigma MDC Units #

H-3 (DIST) 1 2011 1-7.66E+01 1.13E+02 I 1.92E+021 pCi/L F F 10 1 ml 1 103/31/091 80 1 M I 1 1 3E-7 1 2007 1 -8.45E+00 F 8.45E-E+00 1.36E+01 1 pCi/L 1F 3547.87 1 , ml 103/26/09 10:15 1 04/08/091 47007 1 See U I NI N o

-40 1 2007 1 2.76E+02.1 2.69E+01 I 1.32E+01 I pCi/L f7F 3547.87 ml" 03/26/09 10:15 1 041081091 47007 1 Sec 1 + __ TYesl MN-54 1 2007 1 4.90E-01 I 9.61E-0I I 1.59E+00 pCi/L T1 3547.87 *. ml [03/26/09.10:15 1 04/08/091 47007 1 Sec I U I_ NoTI 30-58 1 2007 1 -2.69E-02I1.1.9.84E-01 I 1.59E+00 1 pCi/L II 3547.87 1 ml [03/26/09 10:15 1 04/08/091 47007 1 Sec I.U I No I FE-59 1 2007 1 -2.19E+00 2.08E+00 I 3.25E+00 1 pCi/L . I 3547.87 1 ml 103/26/09 10:15 1 04/08/091 47007 1 Sec IU I NoI "0-60 1 2007 -6.70E-01 I 9.71E-01 I 1.51E+00 I pCi/L T 3547.87 -1 ml [03/26/09 10:15 F04/08/091 47007 1 See I ____ I No I

,N-65 1 2007 F-2.42E+001 2.17E+00 I 3.39E+00 I pCi/L 11 3547.87 1 ml F03/26/09 10:15 1.04/08/091 47007 1 Sec I UJI --- No 414-95 1 2007 F 7.95E-01 1 1.04E+00 F 1.74E+00 I pCi/L 11 3547.87 F ml F03/26/09 10:15 1 04108/091 47007 1 Sec I U.l I No I

  • R 1 2007 F 5.20E-01 1 1.76E+00 F 2.90E+00 I pCi/L 1 ) 3547.87 F ml F03/26/09 10:15 1 04/08/091 47007 1 See IU I __ NoT

-131 1 2007 F 1.25E+00 1. 3.06E+00 F 4.98E+00 I pCi/L 11 3547.87 F ml " 03/26/09 10:15 1 04/08/091 47007 1 Sec IU I No I-

,S-134- 1 2007 F 1.81E-01 I 9.65E-01 I 1-39E+00 I pCi/L I I 3547.87 F ml 03/26/09 10:15 I 04/08/091 47007 1 See IuI I No I "S-137 I 2007 F.-4.55E-01 I .9.67E-01 I 1.55E+00 I pCi/L 11 3547.87 1 ml 103/26/09 10:15 1 04/08/091 47007 1 Sec IU I NoF 3A-140 1 2007 I--2.1IE-01 I 6.10E+00 I 1.01E+01 I pCi/L 11 3547.87 F ml 103/26/09 10:15 1 04/08/091 47007 1 Sec IU I l&N A-140 I 2007 -1.10E+00 2.20E+00 I 3.56E,+00 ppCi/L 1 3547.87 U ml 103/26/09 10:15 1 04/08/091 47007 1 See I U I- TNoI

-226 I 2007 I -4.56E+01 I 2.82E+01 I 4.28E+01 I pCi/L I 1 3547.87 F ml 103/26/09 10:15 1 04/08/091 47007 1 Sec JU I I_-No F

-232 I 2007 . 1.28E+00 3.76E+00 I 6.71E+00 I pCi/L I ' 3547.87 I ml 103/26/09 10:15 1 04/081091 47007 1 See -IUI YesF UFlag Values

= Compound/Analyte not detected or less than 2 sigma No = Peak not identified in gamma spectrum

-+. = Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum U. = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 2 sigma *** Results are reported on an as received basis High = Activity concentration exceeds customerreporting value unless otherwise noted Spec = MDC exceeds customer technical specification * "

L Low recovery MDC - Minimum Detectable Concentration H = High recovery Bolded text indicates reportable value.

Paize 4 of 8

U4ILO/UY U*J ."-t A lefedyno IeCnnologles Lompany L38101 Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX0O1-3EREMPOC-05 Sample ID: I Collect Start: 03/06/2009 15:30 Matrix: Drinking Water (WD)

Station: 1 Collect Stop: 03/24/2009 10:54 Volume:

Description:

Receive Date: 03/30/2009  % Moisture:

LIMS Number: L38101-3 I Conc 2S Volume units Date Date Time Units Fla

-3 (DIST) 2011 1 -6.50E+001 1.18E+02 I 1.95E+02 r pCi/L 11 10 1 ml 1 1 04/01/091 80 f M YU E-7 I 2007 1 -4.44E+00 I 1.19E+01 I 1.93E+01 pCi/L 1 1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 T See IU I 1 No

-40 I 2007 1 1.35E+01 2.24E+0l I 4.15E+01 I pCi/b 1.1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec I U I_ No 1

-54 I 2007 1 -3.0713-01 1.35E+00 I 2.23E+00 [ pCi/L i 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec I U I No I 0-58 I 2007 1 4.95E-01 1.32E+00 1 2.25E+00 pCi/L 1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec I U I_ No E-59 I 2007 1 1.85E+00 3.20E+00 1 5.40E+00 I pCi/L 11 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec [ U _I No 0-60 I 2007 1 3.73E-01 1 1.32E+00 1 2.17E+000 pCi/L 1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec I U IF No_

N-65 I 2007 I -5.70E+00 3.18E+00 1 4.66E+00 1 pCi/L 1.1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec I U I No_ I B-95 2007 [ 8.25E-01 I 1.39E+00 1 2.39E+00 1 pCi/L I I 3503.38 1 ml 103/24/09 10:54 1 04/081091 46995 1 Sec I U I No I R-95 I 2007 I 2.21 E-02 1 2.43E+00 I 4.09E+00 1 pCi/L 11 3503.38 1 ml 103/24/09 10:54 1 04/08/09I 46995 1 Sec I U I __ No 1

-131 1 2007 1 2.67E+00 I 4.3113+00 1 7.37E+00 pCi/L 11 3503.38 . ml 103/24/09 10:54 1 04/08/091 46995 1 Sec [OIU1 No S-134 . 2007 [ 4.06E-01 1 1.36E+00 1 1.95E+001 pCi/L IT 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec [ U I No S-137 1 2007 1 3.63E-01 1 1.3213+00 1 2.17E+00 -pCi/L 11 3503.38 1 ml 103/24/09.10:54 1 04/08/091 46995,1 Sec I U I No I A-140 1 2007 I -3.59E+00I 9.59E+00 I 1.55E+01 pCi/L 1 3503.38 1 ml 103/24/09 10:54 1 04/08/091 46995 1 Sec IU I .__No I A-140 1 2007' -1.28E-01 I 3.27E+00 5.39E+00 pCi/L [ 3503.38 1 ml [03/24/09 10:54. 1 04/08/091 46995 1 Sec U 1_ [No 1

-226 1 2007 1 -3.69E+01I 3.35E+01. F 5.04E+01 1 pCi/L [ 3503.38 1 ml [03/24/09 10:54 1 04/08/091 46995 j Sec IU I I No 1

-232 1 2007 F 2.51 E+00 5.53E+00 F 8.84E+00 I pCi/L I 3503.38 1 ml [03/24/09 10:54 1 04/08/091 46995 1 Sec I U I __No_

Flag Values N No Peak not ident-ified in gamma spectrum U = Compound/AMalyte not detected or less than 2 sigma

+ = Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only) Yes =Peak identified in gamma spectrum U* = Compound/Analyte not detected. Peak not-identified, but forced activity concentration exceeds MDC and 2 sigma **** Results are reported on an as received basis High = Activity concentration exceeds customer reporting value unless otherwise noted Spec = x MDC exceeds customer technical specification L = Low recovery MDC - Minimim Detectable Concentration H -High recovery Bolded text indicates reportable value. Page 5 of 8

VtI,.OIU7 U7.jt ATeledyne Technologies Company L38101 Exelon Nuclear (Oyster Creek)

T-cp* Vn1icrl tnie F.XO01-I APRR.MPOC-05 Sample ID: 37 Collect Start: 03/05/2009 10:45 Matrix: Drinking Water (WD)

Station: 37 Collect Stop: 03/25/2009 11:35 Volume:

Description:

Receive Date: 03130/2009  % Moisture:

LIMS Number: L38101-4 Ru~n A Aliquot Reference Count Count Count IS . Activity Uncertainty .

Radionuclide SOP# Conc 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values H-3 (DIST) ' 2011 T-6.47E+01 1.15E+02 1.94E+02 pCi/L T 10 11 ml I T04/01/091 80 1 M I uI IU I 1No BE-7 F 2007. 9.26E+001 1.01E+01 1.75E+01 F pCi/L T 3501.82 ml 103/25/09.11:35 1 04/08/091 47008 1 Sec K-40. 2007 T 3.01E+00 1.96E+01 I 3.46E+01 F pCi/L 1 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 I Sec JU _ 1 No M-54 r 2007 T -5.53E-01 1 1.13E+00 1.84E+00 I pCi/L 1 1 3501.82 1 ml [03/25/09 11:35 1 04/08/091 47008 1 Sec JU _ INoTF CO-58 F 2007 1 4.41E-01 I I.19E+00 1 2.03E+00 F pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I _ No 1,

_E-59 i 2007 1 6.27E-01 1 2.80E+000 4.59E+00 r pCi/L 1T 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I _ NoFi

,0-60 r 2007 1 9.48E-01 1.62E+00 1 2.17E+00 F pCi/L J f 3501.82 T ml 103/25/09 11:35 1 04/08/091 47008 1 Sec J U I IYesF

?ýN-65 F 2007 1 -1.35E+00[ 2.64E+00 1 4.15E+00 r pCi/L 1 3501.82 1 ml 103/25/0911:35 1 04/08/091 47008 I Sec I U I Nor qB,95 r 2007 1 4.23E-01 1 1.20E+00 1 2.04E+00 F pCi/L 1 3501.82 T ml 03/25/09 11:35 1 04/08/091 47008. 1 Sec -I U I I NoI

_R-95 _ 2007 1 1.08E+00 1 2.13E+00 1 3.51E+000 pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/09§ 47008 1 Sec I U I I No I

-131 r 2007 1 -2.3 1E+001 3.53E+00 1 5.58E+00 r pCi/L 1*1 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I_ NoF "S-134 F 2007 -1.13E+001 1.29E+00 1 1.74E+000 pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I I No__

ýS-137 I 2007 1 1.37E-01 1.21E+00 1 1.98E+00 pCi/L 1 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I I No I 3A-140 i 2007 1 -1.20E+001 8.01E+00 1 1.32E+01 i pCi/L iT 3501.82 1 ml 103/25/09 11:35 1.04/08/091 47008 1 Sec I U I 1No

,A-140 2007 1 2.85E-01 I 2.87E+00 1 4.69E+000 pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec I U I No I RA-226 1 2007 1 3.55E+01 I 3.65E+01 1 3.64E+01 I pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec U __ IYes TH-228 1 2007 1 4.37E+00 1 2.62E3+00 3.12E+00 I pCi/L 11 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 1 Sec +[

+ _I__ Y*

TH-232 I 2007 1 2.89E+00 4.00E+00 1 6.30E+000 pCi/L 1 3501.82 1 ml 103/25/09 11:35 1 04/08/091 47008 I Sec I U _I YesJ Flag Values No = Peak not identified in gamma spectrum U = Compound/Analyte not detected or less than 2 sigma Yes. = Peak identified in gamma spectrum

+ Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only)

  • Results are reported on an as received basis U* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 2 sigma unless otherwise noted High = Activity concentration exceeds customer reporting value Spec = MDC exceeds customer technical specification MDC - Minimum Detectable Concentration L = Low recovery H = High recovery Bolded text indicates reportable value.

-Page6 of 8

ATeledyne Technologies Company L38101 Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3EREMPOC-05.

Sample ID: 38 Collect Start: 03/05/2009 10:00 Matrix: Drinking Water (WD)

-Station: 38 Collect Stop: 03/26/2009 13:45 Volume:

Description:

Receive Date: 03/30/2009  % Moisture:

LIMS Number: L38101-5 Activity Uncertainty Run Aliquot Aliquot Reference Count Count nt Radionuclide SOP# Conc 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values 11 11.03/26/09 13:45 I104/08/09[ 11 Sec IU lJ No 11-1.51E+01 1.66E+01 11 T [1

[I-3 (DIST) I 2011 1.17E+02 pCi/L 1 10 ml 04/01/09 47003 80 M U BE-7 .I 2007 6.50E+00 I l.00E+0 1 I 1.95E+02 pCi/L 3500.36 ml

-40 2007 F 2.65E+00 I 1.77E+01 [13.17E+01 1 pCi/L F _ 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IUI I No 1

-54 1

[ 2007 1 -6.94E-01 F -8.63E-01 I 1.04E+00 I 1.65E+00 F 1.72E+00 1

1 pCi/L rf7[1 3500.36 3500.36 1 1

ml 103/26/09 13:45 1 04/08/091 F1 04/08/09 47003 1 Sec 1F IU I lU I No 1 II No 1 0-58 FE-59 2007 2007 r 2.63E+00F I 1.09E+00 2.31E+00 F 4.04E+00 1 pCi/L pCi/L I

  • F 3500.36 1 ml ml 103/26/09

[03/26/09 13:45 13:45 04/08/091 47003 47003 Sec Sec IU I No I 0-60 1 2007 [-7.56E-02 I 1.02E+00 F 1.66E+00 I pCi/L 1. 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IU I No I

-65 F 2007 1 24.16E+00 2.24E+00 1 3.40E+00 I pCi/l I 1 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IU I 1 No I

_B-95 2007 . 6.51E-02 I 1.14E+000 1.88E+00 F pCi/L I 1 3500.36 F ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IU I 1No F ER-95 F 2007

  • 8.18E-01 1.99E+00 I 3.34E+00 F pCi/L 1 1 3500.36 T ml 103/26/09 13:45 1 04/08/091 47003 1 Sec I U I I NoI R-131 1 2007 1 -7.I1E701 3.11E+00 1 5.10E+00 F pCi/L 1 T 3500.36 1 ml 103/26/09 13:45 I 04/08/091 47003 1 Sec I U [F I No I PS-134 1 2007 1 -3.87E-0l 1 1.49E+00 1 1.56E+00 r pCi/L 1 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec I U I _ No F CS-137 1 2007 1 6.24E-01 1 1.04E1+00 00 F pCi/L 1 _ 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec, I U I I No I BA-140 1 2007 1 7.07E-01 I 7.13E+00 1 1.15E+01 F pCi/L I 1 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec I U I I No I LA-140 . 2007 I -1.1OE+00 I 2.33E+000 3.64E+000 pCi/L 11 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec U No RA-226 1 2007 1 -2.94E+0 I 2.91E+01 I 4.30E+01 I pCi/L [,1 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IU I I No I TH-232 1 2007 I 4.1OE-0l I 4.53E+00 I 7.15E+00 I pCi/L F 1 3500.36 1 ml 103/26/09 13:45 1 04/08/091 47003 1 Sec IU F I No I Sample ID: 39 Collect Start: Matrix: Drinking Water (WD)

Station: 39 Collect Stop: Volume:

Description:

Receive Date: 03/30/2009  % Moisture:

LIMS Number: L38101-6 1Aliquot Reference Count Count Count Radionuclide JSOPone S1op I Activity jUncertaintyI 2 Sigma.

Ait MDC Units R Aliquot Volume Units Date Date Time Units Flag Values SAMPLE FNA I F I F F F F F I IUI I I Comment: I NO SAMPLE!! Station down for repairsl!

Flag Values U = ,Compound/Analyte not detected or less than 2 sigma No Peak not identified in gamma spectrum

+ = Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum U* = Compound/Analyte not detected. Peak not identified, but4forced activity concentration exceeds MDC and 2 sigma

  • Results are reported on an as received basis High = Activity concentration exceeds customer reporting value . unless otherwise noted Spec = MDC exceeds customer technical specification L Low recov-ery. MDC - Minimum Detectable Concentration H = High recovery Bolded text indicates reportable value.

Page 7 of 8

4

  • J A Teledyne Technologies Lompany" L38101 Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3EREMPOC-05 Sample ID: QCA Collect Start: 03/06/2009 15:30 Matrix: Drinking Water (WD)

Station: QCA Collect Stop: 03/24/2009 10:54 Volume:

Description:

Receive Date: 03/30/2009  % Moisture:

LIMS Number: L38101-7 Radionuclide SCon So# Activity Uncertainty 2 Sigma Un t 1DRun

Aliquot Volume Aliquot.

Units Reference Date Count Date CouniTCount Time Units Flag Values 4-3 (DIST) 1 2011 1 1.08E+01 1 1.19E+02 1.95E+02 I pCi/L F 10 1 ml 1 04/01/091 80 1 M U I BE-7 1 2007 1 5.97E+00 1.22E+01 I 2.02E+01 I pCi/L F 3505.52 1 ml 103/24/09 10:54 1 04/08/091 46992 1 See IU I I No I

-40 1 2007 1 3.14E+01 2.91E+01 I 1.75E+01 1 pCi/L F 3505.52 1 ml 03/24/09 10:54 1 04/08/091 46992 1 See 1+ _ I Yes 1, 11 1.18E+00 1 1.87E+00 1 1 10:54 F 04/08/091 MN-54

,0-58 E-59 1 2007 2007 2007 1 -1.22E+00 1 -7.70E-01 1 -8.62E-01 I r 1.25E+00 I 2.02E+0I 2.79E+00 F 4.52E+00 1 pCi/L pCi/L pCi/b IF 3505.52 F 3505.52 3505.52 1

i i

ml ml ml 03124109 103/24/09

[03/24/09 10:54 I 04/08/091 10:54 1 04/08/091 46992 I See 46992 1 Sec 46992 1 See U I 11UU 1_

iNo I INol I No T-'

0-60 . 1 2007 F -7.05E-021 1.14E+00 F 1.85E+00 1 pCi/L TF [3505.52 i ml [03/24/09 10:54 . 04/08/091 46992 1 See JU _ 1No.1 T-65 2007 F-3.55E+001 2.55E+00 43.82E+00 1 pCi/L T - 3505.52 1 ml F03/24/09 10:54 F 04/08/09 46992 1 Sec 1U 1 1 No I N-95 2007 F 7.37E-02 I 1.35E+00 F 2.32E+00 I pCi/L IF 3505.52 1 ml 103/24/09 10:54 1 04/08/091 46992 F Sec U l __ iNol R-95 , 1 2007 F 2.14E+00 I 2.38E+00 I 4.17E+00 I pCi/L 1 F 3505.52 F ml [03/24/09 10:54 1 04108/091 46992 1 See I U _I No

[-131 2007 6.18E-01 7 4.48E+00 1 27.39E+00 I pCi/L i 3505.52 1 ml 103/24/09 10:54 1 04/08/091 46992 1 See I U I I Nol S-134 1 2007 F-2.53E+001 1.28E+00 F 1.87E+00 I pCi/b 1_* 3505.52 [ ml 103/24/09 10:54 1 04/08/09 46992 F Sec l U __ INol S-137 1 2007 F-6.16E-02 41.28E+00 .9E+00 1 pCi/L I_ 3505.52 F ml 103/24/09 10:54 1 04/08/091 46992 F Sec IU I Nol PA-140 F 2007 F-1.02E+00I 9.78E+00 F 1.57E+01 F pCi/L I 3505.52 I ml F03/24/09 10:54 1 04/08/091 46992 1 See IU I No JA-140 I 2007 I 1.82E-01 I 3.15E+00 I 5.11E+000 pCi/L 1 3505.52 F ml 1.03/24/09 10:54 1 04/08/091 46992 1 Sec IU I I No

-226 . 2007 I 1.19E+01 I 4.25E+01 I 4.62E+01 I pCi/L 1 1 3505.52 1 ml 103/24/09 10:54 1 04/08/091 .46992 1 See IU I I Yes F

-232 J 2007, I -5.76E-01 I 5.51E+00 I 8.73E+00 I pCi/L I . 3505.52 1 ml 103/24/09 10:54 1 04/08/091 46992 F See IU I No H Flag Values U = Compound/Analyte not detected or less than 2 sigma No = Peak not identified in gamma spectrum

+ = Activity concentration exceeds MDC and 2 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum U* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 2 sigma **** Results are reported on an as received basis High = Activity concentration exceeds customer reporting value unless otherwise noted Spec = MDC exceeds customer technical specification L Low recovery MDC - Minimum Detectable Concentration H = High recovery Bolded text indicates reportable value.

Page 8 of 8