ML17266A144: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 2: Line 2:
| number = ML17266A144
| number = ML17266A144
| issue date = 02/01/1980
| issue date = 02/01/1980
| title = LER 80-001/03L-0:on 800102,During Surveillance Testing of IA Diesel Generator,Fuel Transfer Pump Failed to Start. Failure Caused by Dirty Starter Contactor.Pump Cleaned & Returned to Svc
| title = LER 80-001/03L-0:on 800102,during Surveillance Testing of IA Diesel Generator,Fuel Transfer Pump Failed to Start. Failure Caused by Dirty Starter Contactor.Pump Cleaned & Returned to Svc
| author name = SCHOPPMAN M A
| author name = SCHOPPMAN M A
| author affiliation = FLORIDA POWER & LIGHT CO.
| author affiliation = FLORIDA POWER & LIGHT CO.

Revision as of 01:44, 27 February 2018

LER 80-001/03L-0:on 800102,during Surveillance Testing of IA Diesel Generator,Fuel Transfer Pump Failed to Start. Failure Caused by Dirty Starter Contactor.Pump Cleaned & Returned to Svc
ML17266A144
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 02/01/1980
From: SCHOPPMAN M A
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17207A838 List:
References
LER-80-001-03L-02, LER-80-1-3L-2, NUDOCS 8002220168
Download: ML17266A144 (2)