ML17333A636: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:1~hrCATEGORYj.REGULATCINFORMATION DISTRIBUTIONSTEM (RIDE)ACCESSION NBR:9611150063 DOC.DATE:
{{#Wiki_filter:1~h r CATEGORY j.REGULATC INFORMATION DISTRIBUTIONSTEM (RIDE)ACCESSION NBR:9611150063 DOC.DATE: 96/11/07 NOTARIZED:
96/11/07NOTARIZED:
NO FACIL:50-315 Donald.C.Cook Nuclear Power Plant, Unit 1, indiana M 50-316 Donald C.Cook Nuclear Power Plant, Unit 2, Indiana M AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.E American Electric Power Co., Inc.RECIP.NAME RECIPIENT AFFILIATION Document.Control Branch (Document Control Desk)DOCKET 05000315 05000316
NOFACIL:50-315 Donald.C.CookNuclearPowerPlant,Unit1,indianaM50-316DonaldC.CookNuclearPowerPlant,Unit2,IndianaMAUTH.NAMEAUTHORAFFILIATION FITZPATRICK,E.E AmericanElectricPowerCo.,Inc.RECIP.NAME RECIPIENT AFFILIATION Document.ControlBranch(Document ControlDesk)DOCKET0500031505000316


==SUBJECT:==
==SUBJECT:==
ForwardsRAIrerequestsforrelieftoCodeCasesN-521,N-491,N-509 6N-524.rDISTRIBUTION CODE:A047DCOPIESRECEIVED'LTR LENCLSIZE:IITITLE:ORSubmittal:
Forwards RAI re requests for relief to Code Cases N-521, N-491,N-509 6 N-524.r DISTRIBUTION CODE: A047D COPIES RECEIVED'LTR L ENCL SIZE: II TITLE: OR Submittal:
lnservice/Testing/Relief fromASMCode-GL-9-04NOTES:TERECIPIENT IDCODE/NAME PD3-3LAHICKMANFJ INTERNAL:
lnservice/Testing/Relief from ASM Code-GL-9-04 NOTES: T E RECIPIENT ID CODE/NAME PD3-3 LA HICKMANFJ INTERNAL: AEOD/SPD/RAB NRR/DE/EMEB OGC/HDS2 RES/DSIR/EIB COPIES LTTR ENCL 1 1 1 1-1 1 1 1 1 0 1 1 RECIPIENT ID CODE/NAME PD3-3 PD E CENTER 1 NUDOCS-A TRACT RES/DET/EMMEB COPIES LTTR ENCL 1 1 1 1 1 1 1 1 0 EXTERNAL: LITCO ANDERSON NRC PDR 1 1 NOAC 1 1 1 1 D 0 E N NOTE TO ALL"RIDS" RECIPIENTS:
AEOD/SPD/RAB NRR/DE/EMEB OGC/HDS2RES/DSIR/EIB COPIESLTTRENCL1111-11111011RECIPIENT IDCODE/NAME PD3-3PDECENTER1NUDOCS-ATRACTRES/DET/EMMEB COPIESLTTRENCL111111110EXTERNAL:
PLEASE HELP US TO REDUCE WASTE.TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 13 ENCL 12 American Electric P~er Nuclear Generation+p 500 Circle Drive Buchanan, MI 491071395 November 7, 1996 Docket Nos.: 50-315 50-316 U.S.Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.20555 Gentlemen:
LITCOANDERSONNRCPDR11NOAC1111D0ENNOTETOALL"RIDS"RECIPIENTS:
ANMICIN tFI.KCfRIC POWM AEP:NRC:0969AA Donald C.Cook Nuclear Plant Units 1 and 2 THIRD 10-YEAR INTBRVAL INSERVICE INSPECTION PROGRAM AND ASSOCIATED REQUESTS FOR RELIEF (TAC NOS.M94871 AND M94872)REQUEST FOR ADDITIONAL INFORMATION References Letter AEP:NRC:0969AW, E.E.Fitzpatri,ck to U.S.NRC,"Donald C.Cook Nuclear Plant Units 1 and 2, THIRD 10-YEAR INTERVAL INSERVICB INSPECTION PROGRAM AND ASSOCIATED REQUESTS FOR RELIEF (TAC NOS.M94871 AND M94872), REQUEST FOR ADDITIONAL INFORMATION" dated, September 10, 1996.2.Letter, C.A.Carpenter to E.E.Fitzpatrick,"D.C.COOK, UNITS 1 AND 2, REQUESTING APPROVAL OF CODE CASE N-498-1 AS AN ALTERNATIVE TO THB REQUIRED HYDROSTATIC PRESSURE TEST (TAC NOS.M91783 AND M91784)", dated July 5, 1995.The third 10-year inservice inspection plan for Cook Nuclear Plant utilizes code cases that have not been incorporated into Regulatory Guide 1.147.Because of this, NRC approval of the use of these code cases as alternatives to the ASME Section XI requirements is required, The particular code cases for which approval is required were identified in our September 10, 1996, letter (reference 1).The attachments to this letter provide relief requests that would allow Cook Nuclear Plant to use Code Cases N-521, N-491-1, N-509, and N-524 as alternatives to the requirements of the 1989 edition of ASME Code Section XI.Please note that although Code Case N-498-1 was identified in reference 1, this letter does not contain a relief request for use of this code case because we previously obtained approval for its use (reference 2).Approval of these requests is required by July 1, 1997.E.E.Fitzpatrick Vice President Attachments h 9'6ii150063 961107~i.PDR).ADOCK 050003i5: 6'~PORE li U.S.Nuclear Regulatory Commission Page 2 AEP:NRC:0969AA cc: A.A.Blind A.B.Beach MDEQ-DW&RPD NRC Resident Inspector J.R.Padgett Attachment 1 to AEP:NRC:0969AA BACKGROUND INPORMATION AND JUSTIFICATION TO USE CODE CASE N-521 AS AN ALTERNATIVE POR THE EXAMINATION OP NOZZLE TO VESSEL AND SAFE END WELDS AND INSIDE RADIUS SECTIONS POR THE COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10" YEAR INTERVAL
PLEASEHELPUSTOREDUCEWASTE.TOHAVEYOURNAMEORORGANIZATION REMOVEDFROMDISTRIBUTION LISTSORREDUCETHENUMBEROFCOPIESRECEIVEDBYYOUORYOURORGANIZATION, CONTACTTHEDOCUMENTCONTROLDESK(DCD)ONEXTENSION 415-2083TOTALNUMBEROFCOPIESREQUIRED:
LTTR13ENCL12 AmericanElectricP~erNuclearGeneration+p 500CircleDriveBuchanan, MI491071395 November7,1996DocketNos.:50-31550-316U.S.NuclearRegulatory Commission ATTN:DocumentControlDeskWashington, D.C.20555Gentlemen:
ANMICINtFI.KCfRIC POWMAEP:NRC:0969AA DonaldC.CookNuclearPlantUnits1and2THIRD10-YEARINTBRVALINSERVICE INSPECTION PROGRAMANDASSOCIATED REQUESTSFORRELIEF(TACNOS.M94871ANDM94872)REQUESTFORADDITIONAL INFORMATION References LetterAEP:NRC:0969AW, E.E.Fitzpatri,ck toU.S.NRC,"DonaldC.CookNuclearPlantUnits1and2,THIRD10-YEARINTERVALINSERVICB INSPECTION PROGRAMANDASSOCIATED REQUESTSFORRELIEF(TACNOS.M94871ANDM94872),REQUESTFORADDITIONAL INFORMATION" dated,September 10,1996.2.Letter,C.A.Carpenter toE.E.Fitzpatrick, "D.C.COOK,UNITS1AND2,REQUESTING APPROVALOFCODECASEN-498-1ASANALTERNATIVE TOTHBREQUIREDHYDROSTATIC PRESSURETEST(TACNOS.M91783ANDM91784)",
datedJuly5,1995.Thethird10-yearinservice inspection planforCookNuclearPlantutilizescodecasesthathavenotbeenincorporated intoRegulatory Guide1.147.Becauseofthis,NRCapprovaloftheuseofthesecodecasesasalternatives totheASMESectionXIrequirements isrequired, Theparticular codecasesforwhichapprovalisrequiredwereidentified inourSeptember 10,1996,letter(reference 1).Theattachments tothisletterprovidereliefrequeststhatwouldallowCookNuclearPlanttouseCodeCasesN-521,N-491-1,N-509,andN-524asalternatives totherequirements ofthe1989editionofASMECodeSectionXI.PleasenotethatalthoughCodeCaseN-498-1wasidentified inreference 1,thisletterdoesnotcontainareliefrequestforuseofthiscodecasebecausewepreviously obtainedapprovalforitsuse(reference 2).ApprovaloftheserequestsisrequiredbyJuly1,1997.E.E.Fitzpatrick VicePresident Attachments h9'6ii150063 961107~i.PDR).ADOCK050003i5:
6'~POREli U.S.NuclearRegulatory Commission Page2AEP:NRC:0969AA cc:A.A.BlindA.B.BeachMDEQ-DW&RPDNRCResidentInspector J.R.Padgett Attachment 1toAEP:NRC:0969AA BACKGROUND INPORMATION ANDJUSTIFICATION TOUSECODECASEN-521ASANALTERNATIVE PORTHEEXAMINATION OPNOZZLETOVESSELANDSAFEENDWELDSANDINSIDERADIUSSECTIONSPORTHECOOKNUCLEARPLANTUNITS1and2THIRD10"YEARINTERVAL


Attachment-1toAEP:NRC:0969AA Page1System/Component forwhichreliefisrequested Nozzletovesselwelds,nozzleinsideradiussections, and'nozzletosafeendweldsforCookNuclearPlant,units1and2.lZ.CodeRequirements Examination categories B-DandB-F,itemsB3.90andB3.100ofASMESectionXIcode,1989editionwithnoaddenda,require100~volumetric examination perIWA-2500-7 ofatleast25~butnotmorethan50%ofreactorvesselnozzletovesselweldsandnozzleinsideradiussectionsbytheendofthefirstperiod.Examination categoryB-F,item5.10requires100%surfaceandvolumetric examination perfigureIWB-2500-8 ofdissimilar metalnozzletosafeendweldsthatmaybeexaminedcoincident withthevesselnozzleexaminations.
Attachment-1 to AEP:NRC:0969AA Page 1 System/Component for which relief is requested Nozzle to vessel welds, nozzle inside radius sections, and'nozzle to safe end welds for Cook Nuclear Plant, units 1 and 2.lZ.Code Requirements Examination categories B-D and B-F, items B3.90 and B3.100 of ASME Section XI code, 1989 edition with no addenda, require 100~volumetric examination per IWA-2500-7 of at least 25~but not more than 50%of reactor vessel nozzle to vessel welds and nozzle inside radius sections by the end of the first period.Examination category B-F, item 5.10 requires 100%surface and volumetric examination per figure IWB-2500-8 of dissimilar metal nozzle to safe end welds that may be examined coincident with the vessel nozzle examinations.
ZZI.BasisforcodereliefTheASMESectionXIcoderequirements fortheexamination ofreactorpressurevesselnozzletovesselwelds,thenozzleinsideradiussections, andnozzletosafeendweldsstipulate adistribution oftheseexaminations inatleasttwoofthethreeperiods.Thesamesequenceestablished inthefirst10-yearintervalmustbeusedforsuccessive 10-yearintervals.
ZZI.Basis for code relief The ASME Section XI code requirements for the examination of reactor pressure vessel nozzle to vessel welds, the nozzle inside radius sections, and nozzle to safe end welds stipulate a distribution of these examinations in at least two of the three periods.The same sequence established in the first 10-year interval must be used for successive 10-year intervals.
Theimplementation ofthesecoderequirements wouldresultinanadditional set-upoftheautomated ultrasonic (UT)equipment usedtoexaminethenozzletovesselwelds,insideradiussections, andnozzletosafeendwelds.Additionally, personnel radiation exposurewouldincreaseduetotheadditional set-upofautomated UTequipment andsupporthoursneededtoperformthisexamination.
The implementation of these code requirements would result in an additional set-up of the automated ultrasonic (UT)equipment used to examine the nozzle to vessel welds, inside radius sections, and nozzle to safe end welds.Additionally, personnel radiation exposure would increase due to the additional set-up of automated UT equipment and support hours needed to perform this examination.
Thispositionisfurthersupported bythefollowing.
This position is further supported by the following.
CodeCaseN-521issuedbytheASMESectionXIorganization providesanacceptable alternative tothecodemethodfortheexamination ofthenozzletovesselandsafeendwelds,andinsideradiussections.
Code Case N-521 issued by the ASME Section XI organization provides an acceptable alternative to the code method for the examination of the nozzle to vessel and safe end welds, and inside radius sections.This code relief was approved for use for the V.C.Summer Nuclear Plant, for the second 10-year interval (reference 1).Alternative Method As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform all the nozzle to vessel, nozzle to safe end welds, and inside radius section examinations in the third period of the third interval.V.Justification for granting code relief Code Case N-521 imposes the following conditions that must be met prior to its use:
ThiscodereliefwasapprovedforusefortheV.C.SummerNuclearPlant,forthesecond10-yearinterval(reference 1).Alternative MethodAsanalternative totherequirements ofthe1989editionoftheASMESectionXIcode,itisproposedtoperformallthenozzletovessel,nozzletosafeendwelds,andinsideradiussectionexaminations inthethirdperiodofthethirdinterval.
Attachment 1 to AEP:NRC:0969AA Page 2 no inservice repairs or replacements by welding have been performed on the nozzle to vessel and safe end welds, or inside radius section;the nozzle to vessel and safe end welds and the inside radius section examination volume shall not contain flaws that require successive examinations in accordance with ZWA-2420(b);
V.Justification forgrantingcodereliefCodeCaseN-521imposesthefollowing conditions thatmustbemetpriortoitsuse:
and the unit is not in the first 10-year interval.Cook Nuclear Plant has not performed inservice repairs or replacements on the nozzle to vessel and safe end welds, and inside radius sections.Flaws have not been identified in the examination volume that require successive examinations and both units 1 and 2 are in the third 10-year interval;therefore, applicability of this code case has been met.The deferral of all examinations to the third period of the third 10-year interval will result in reduced set-up hours and personnel radiation exposure hours due to consolidation of manpower efforts (set-up and support)to the third period of the third 10-year interval.The examination of nozzle to vessel welds from the shell side was performed for units 1 and 2 in the third period of the second 10-year interval during the 1995 and 1996 refueling outages.Examination of nozzle to vessel welds from the bore inside diameter (four for unit 1 and two for unit 2)were performed in the first period to meet code requ'rements.
Attachment 1toAEP:NRC:0969AA Page2noinservice repairsorreplacements byweldinghavebeenperformed onthenozzletovesselandsafeendwelds,orinsideradiussection;thenozzletovesselandsafeendweldsandtheinsideradiussectionexamination volumeshallnotcontainflawsthatrequiresuccessive examinations inaccordance withZWA-2420(b);
The second 10-year interval examination of the inside radius sections and nozzle to safe end welds was performed in accordance with table ZWA-2500-1 of the code (at least 25%but not more than 50%in the first period and the balance of 100%in the third period).Four of the eight inside radius sections and nozzle to safe end welds were performed in the third period (1995)of the second 10-year interval for unit 1.Six of eight inside radius sections and nozzle to safe end weld'or unit 2 were examined in 1996.Because we performed a majority of the examinations in the third period of the second 10-year interval, and there were no flaws detected in any of the examinations conducted in the first or second intervals, it is reasonable to conclude that the deferment of all the examinations to the third period of the third 10-year interval will not compromise the safety of plant personnel or equipment.
andtheunitisnotinthefirst10-yearinterval.
The alternate test using Code Case N-521 eliminates the hardship of performing two automated examinations per inspection interval while providing an acceptable level of quality and safety for Cook Nuclear Plant.VZ.Reference Letter, F.J.Hebdon to G.J.Taylor,"Evaluation of Relief Requests for RR-07 and IWA-5242(a), Virgil C.Summer Nuclear Station (TAC Nos.M94363 and M94364)," dated April 11, 1996.
CookNuclearPlanthasnotperformed inservice repairsorreplacements onthenozzletovesselandsafeendwelds,andinsideradiussections.
Attachment 2 to AEP:NRC:0969AA BACKGROUND INFORMATION AND JUSTIFICATION TO USE CODE CASE N-491-1 AS AN ALTERNATIVE FOR THE ZNSPECTZON OF CLASS 1, 2, 3, AND MC COMPONENT SUPPORTS FOR COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10-YEAR INTERVAL Attachment 2 to AEP:NRC:0969AA Page 1 System/Component for which, relief is requested Class 1, 2, 3, and MC component supports.Code Requirements Table IWF-2500-1, examination category F-A, items F1.10 through F1.70 of the 1989 edition of ASME Section XI code, requires visual and VT-3 examination of class 1, 2, and 3'upports in accordance with the schedule established for components under IWB, IWC, IWD and IWE.III.Basis for code relief The 1989 edition of the ASME Section XI code requires the examination of component supports be based on a frequency in accordance with the IWB, IWC, IWD, and IWE components for each interval.The proposed al"ernative method to be used by Cook Nuclear Plant and outlined in ASME Code Case N-491-1 provides a selection criteria based on applying a reasonable percentage of examinations for each class of component supports.Significant personnel radiation exposure and contamination savings are predicted to result from the implementation of these requirements compared with the requirements stated in the 1989 edition of the ASME Section XI code.IV.Code Case N-491-1 was approved by the ASME Section XI organization in April 1993, and provides an acceptable alternative to the code method for the examination of component supports.Alternative Method V.As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform examination of component supports in accordance with the requirements established in ASME approved Code Case N-491-1.Justification for granting code relief The ASME Section XI code organization has approved the use of Code Case N-491-1 as an acceptable alternative'o the code requirements for the examination of component supports.Piping systems are examined frequently during plant walkdowns with thy units operating or during planned or unplanned outages.If the failure or degradation of a support is observed during these walkdowns, whether they are formal visual/VT-3 examinations or informal observations, prompt action is taken including the evaluation, repair, and/or replacement of"supports.
Flawshavenotbeenidentified intheexamination volumethatrequiresuccessive examinations andbothunits1and2areinthethird10-yearinterval; therefore, applicability ofthiscodecasehasbeenmet.Thedeferralofallexaminations tothethirdperiodofthethird10-yearintervalwillresultinreducedset-uphoursandpersonnel radiation exposurehoursduetoconsolidation ofmanpowerefforts(set-upandsupport)tothethirdperiodofthethird10-yearinterval.
The use of the proposed alternative for the inspection and examination of component supports will result in significant labor and dose savings while providing an acceptable level of quality and safety.
Theexamination ofnozzletovesselweldsfromtheshellsidewasperformed forunits1and2inthethirdperiodofthesecond10-yearintervalduringthe1995and1996refueling outages.Examination ofnozzletovesselweldsfromtheboreinsidediameter(fourforunit1andtwoforunit2)wereperformed inthefirstperiodtomeetcoderequ'rements.
Attachment 3 to AEPsNRCs0969AA BACKGROUND INFORMATION AND JUSTZPICATION TO USE CODE CASE N-509 AS ALTERNATIVE RULES POR THE SELECTZON AND INSPECTION OP CLASS 1, 2, and 3 INTEGRALLY WELDED ATTACHMENTS POR COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10-YEAR INTERVAL r
Thesecond10-yearintervalexamination oftheinsideradiussectionsandnozzletosafeendweldswasperformed inaccordance withtableZWA-2500-1 ofthecode(atleast25%butnotmorethan50%inthefirstperiodandthebalanceof100%inthethirdperiod).Fouroftheeightinsideradiussectionsandnozzletosafeendweldswereperformed inthethirdperiod(1995)ofthesecond10-yearintervalforunit1.Sixofeightinsideradiussectionsandnozzletosafeendweld'orunit2wereexaminedin1996.Becauseweperformed amajorityoftheexaminations inthethirdperiodofthesecond10-yearinterval, andtherewerenoflawsdetectedinanyoftheexaminations conducted inthefirstorsecondintervals, itisreasonable toconcludethatthedeferment ofalltheexaminations tothethirdperiodofthethird10-yearintervalwillnotcompromise thesafetyofplantpersonnel orequipment.
Attachment 3 to AEP:NRC:0969AA Page 1 System/Component for which relief is requested Class 1, 2, and 3 integrally welded attachments.
Thealternate testusingCodeCaseN-521eliminates thehardshipofperforming twoautomated examinations perinspection intervalwhileproviding anacceptable levelofqualityandsafetyforCookNuclearPlant.VZ.Reference Letter,F.J.HebdontoG.J.Taylor,"Evaluation ofReliefRequestsforRR-07andIWA-5242(a),
Code Requirements Table IWB-2500-1, examination categories B-H and B-K-1;table IWC-2500-1, examination category C-C;and table IWD-2500-1, examination'ategories D-A, D-B, and D-C of the 1989 edition of ASME Section XI code require surface or volumetric examination for welded attachments of vessels, piping, pumps, and valves.III.Basis for code relief The 1989 edition of the ASME Section XI code requires the examination of integrally welded attachments to be based on the requirements indicated in tables IWB-2500-1 through IWD-2500-1.Frequency and extent of examination are in accordance with these tables and the inspection program chosen by the owner.The proposed alternative method to be used by Cook Nuclear Plant and outlined in ASME Code Case N-509 provides selection criteria based on identified deformation of the component support members found in the plant either during operation, refueling, maintenance, examination, inservice inspection, or testing.The criteria stated in Code Case N-509 are more reasonable than the random examination of all welded attachments in that they focus the examination and the evaluation on those component supports and welded attachments that are susceptible to early failure.Significant personnel radiation exposure and contamination savings are predicted to result from the implementation of these requirements.
VirgilC.SummerNuclearStation(TACNos.M94363andM94364),"
Code Case N-509 was approved in November 1992 by the ASME Section XI organization and provides an acceptable alternative to the code method for the examination of welded attachments for vessels, piping, pumps, and valves.IV.'lternative Method As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform examination of welded attachments for vessels, piping, pumps, and valves in accordance with Code Case N-509.V.Justification for granting code relief The ASME Section XI code organization has approved the use of Code Case N-509 as an acceptable alternative,to the code requirements for the examination of welded attachments for vessels, piping, pumps, and valves.Component supports are examined frequently during plant walkdowns, both with the units operating or during planned or unplanned outages.If a failure or deformation of a component support is observed during these walkdowns, a surface examination of the appropriate boundary of the welded Attachment 3 to AEP:NRC:0969AA Page 2 attachment shall be performed in accordance with Code Case N-509.This examination strategy is more reasonable than the code method of random examination of welded attachments due to its focus on higher stressed component supports that would be more susceptible to failure in the attachment weld.The use of the proposed alternative for the inspection and examination of welded attachments will result in significant labor and dose savings while providing an acceptable level of quality and safety.
datedApril11,1996.
Attachment 4 to AEP:NRC:0969AA BACKGROUND INFORMATION AND KJSTIFICATZON FOR THE USE OF CODE CASE N-524 AS AN ALTERNATIVE FOR THE EXAMZHATION REQUIREMENTS FOR LONGITUDINAL WELDS ZN CLASS 1 AND 2 PIPING FOR COOK NUCLEAR PLANT UNITS 1 AND 2 THIRD 10-YEAR INTERVAL Attachment 4 to AEP:NRC:0969AA Page 1 IZ.System/Component for which relief is requested Class 1 and 2 longitudinal welds in piping.Code Requirements Table IWB-2500-1, examination category B-J, items B9.12 and B9.22, and table IWC-2500-1, examination categories C-F-1 and C-F-2 of ASME Section XI code, 1989 edition with no addenda, require volumetric and/or surface examination from the intersection of longitudinal and circumferential welds for a distance of one pipe diameter in length but no greater than one foot maximum for class 1 welds and two and one-half times the pipe wall thickness for class 2 welds.IIZ.Basis for code relief ZV.The 1989 edition of ASME Section XI code requires the examination of longitudinal class 1 and 2 piping welds be in accordance with the requirements of tables IWB-2500-1 and IWC-2500-1.
Attachment 2toAEP:NRC:0969AA BACKGROUND INFORMATION ANDJUSTIFICATION TOUSECODECASEN-491-1ASANALTERNATIVE FORTHEZNSPECTZON OFCLASS1,2,3,ANDMCCOMPONENT SUPPORTSFORCOOKNUCLEARPLANTUNITS1and2THIRD10-YEARINTERVAL Attachment 2toAEP:NRC:0969AA Page1System/Component forwhich,reliefisrequested Class1,2,3,andMCcomponent supports.
The length of weld examined shall be one pipe diameter but no greater than one foot maximum for class 1 welds and two and one-half times the wall thickness for class 2 welds.Class 1 and 2 longitudinal piping welds do exist in~arious Cook Nuclear Plant systems.Code Case N-524 provides an acceptable alternative that examines the intersectional area of circumferential and longitudinal welds, which is the area most prone to failure.This position is further supported by the approval of Code Case N-524 by the ASME Section XI organization as an acceptable alternative to the code examination of class 1 and 2 longitudinal piping welds.Alternative Method V.As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to examine class 1 and 2 longitudinal piping welds in accordance with the requirements stated in ASME Code Case N-524.Justification for granting code relief Code Case N-524 was approved by the ASME Section XI code organization for the examination of class 1 and 2 longitudinal pipe welds as an alternate method to the code examination.
CodeRequirements TableIWF-2500-1, examination categoryF-A,itemsF1.10throughF1.70ofthe1989editionofASMESectionXIcode,requiresvisualandVT-3examination ofclass1,2,and3'upports inaccordance withthescheduleestablished forcomponents underIWB,IWC,IWDandIWE.III.BasisforcodereliefThe1989editionoftheASMESectionXIcoderequirestheexamination ofcomponent supportsbebasedonafrequency inaccordance withtheIWB,IWC,IWD,andIWEcomponents foreachinterval.
This code case accepts the code examination of the circumferential weld volume as sufficient in determining the integrity of the intersection of circumferential and longitudinal welds.The intersection of the longitudinal and circumferential welds is expected to possess the highest residual stresses of the collective weld due to the manufacturing process and therefore, a thorough code examination of the circumferential weld volume would be adequate in determining the integrity of this area.Additionally, there have been no reported failures in the industry, where the failure was initiated outside the intersection area that would be examined during the ultrasonic testing of the circumferential weld.
Theproposedal"ernative methodtobeusedbyCookNuclearPlantandoutlinedinASMECodeCaseN-491-1providesaselection criteriabasedonapplyingareasonable percentage ofexaminations foreachclassofcomponent supports.
Attachment 4 to AEP:NRC:0969AA Page 2 The implementation of this code case will significantly reduce labor and radiation exposure due to decreased scaffolding installation and insulation removal for visual access to the longitudinal welds,.The use of this code case provides an acceptable alternative to the current code method of examining class 1 and 2 longitudinal piping welds while providing an acceptable level of quality and safety.
Significant personnel radiation exposureandcontamination savingsarepredicted toresultfromtheimplementation oftheserequirements comparedwiththerequirements statedinthe1989editionoftheASMESectionXIcode.IV.CodeCaseN-491-1wasapprovedbytheASMESectionXIorganization inApril1993,andprovidesanacceptable alternative tothecodemethodfortheexamination ofcomponent supports.
Alternative MethodV.Asanalternative totherequirements ofthe1989editionoftheASMESectionXIcode,itisproposedtoperformexamination ofcomponent supportsinaccordance withtherequirements established inASMEapprovedCodeCaseN-491-1.Justification forgrantingcodereliefTheASMESectionXIcodeorganization hasapprovedtheuseofCodeCaseN-491-1asanacceptable alternative'o thecoderequirements fortheexamination ofcomponent supports.
Pipingsystemsareexaminedfrequently duringplantwalkdowns withthyunitsoperating orduringplannedorunplanned outages.Ifthefailureordegradation ofasupportisobservedduringthesewalkdowns, whethertheyareformalvisual/VT-3 examinations orinformalobservations, promptactionistakenincluding theevaluation, repair,and/orreplacement of"supports.
Theuseoftheproposedalternative fortheinspection andexamination ofcomponent supportswillresultinsignificant laboranddosesavingswhileproviding anacceptable levelofqualityandsafety.
Attachment 3toAEPsNRCs0969AA BACKGROUND INFORMATION ANDJUSTZPICATION TOUSECODECASEN-509ASALTERNATIVE RULESPORTHESELECTZON ANDINSPECTION OPCLASS1,2,and3INTEGRALLY WELDEDATTACHMENTS PORCOOKNUCLEARPLANTUNITS1and2THIRD10-YEARINTERVAL r
Attachment 3toAEP:NRC:0969AA Page1System/Component forwhichreliefisrequested Class1,2,and3integrally weldedattachments.
CodeRequirements TableIWB-2500-1, examination categories B-HandB-K-1;tableIWC-2500-1, examination categoryC-C;andtableIWD-2500-1, examination'ategories D-A,D-B,andD-Cofthe1989editionofASMESectionXIcoderequiresurfaceorvolumetric examination forweldedattachments ofvessels,piping,pumps,andvalves.III.BasisforcodereliefThe1989editionoftheASMESectionXIcoderequirestheexamination ofintegrally weldedattachments tobebasedontherequirements indicated intablesIWB-2500-1 throughIWD-2500-1.Frequency andextentofexamination areinaccordance withthesetablesandtheinspection programchosenbytheowner.Theproposedalternative methodtobeusedbyCookNuclearPlantandoutlinedinASMECodeCaseN-509providesselection criteriabasedonidentified deformation ofthecomponent supportmembersfoundintheplanteitherduringoperation, refueling, maintenance, examination, inservice inspection, ortesting.ThecriteriastatedinCodeCaseN-509aremorereasonable thantherandomexamination ofallweldedattachments inthattheyfocustheexamination andtheevaluation onthosecomponent supportsandweldedattachments thataresusceptible toearlyfailure.Significant personnel radiation exposureandcontamination savingsarepredicted toresultfromtheimplementation oftheserequirements.
CodeCaseN-509wasapprovedinNovember1992bytheASMESectionXIorganization andprovidesanacceptable alternative tothecodemethodfortheexamination ofweldedattachments forvessels,piping,pumps,andvalves.IV.'lternative MethodAsanalternative totherequirements ofthe1989editionoftheASMESectionXIcode,itisproposedtoperformexamination ofweldedattachments forvessels,piping,pumps,andvalvesinaccordance withCodeCaseN-509.V.Justification forgrantingcodereliefTheASMESectionXIcodeorganization hasapprovedtheuseofCodeCaseN-509asanacceptable alternative,to thecoderequirements fortheexamination ofweldedattachments forvessels,piping,pumps,andvalves.Component supportsareexaminedfrequently duringplantwalkdowns, bothwiththeunitsoperating orduringplannedorunplanned outages.Ifafailureordeformation ofacomponent supportisobservedduringthesewalkdowns, asurfaceexamination oftheappropriate boundaryofthewelded Attachment 3toAEP:NRC:0969AA Page2attachment shallbeperformed inaccordance withCodeCaseN-509.Thisexamination strategyismorereasonable thanthecodemethodofrandomexamination ofweldedattachments duetoitsfocusonhigherstressedcomponent supportsthatwouldbemoresusceptible tofailureintheattachment weld.Theuseoftheproposedalternative fortheinspection andexamination ofweldedattachments willresultinsignificant laboranddosesavingswhileproviding anacceptable levelofqualityandsafety.
Attachment 4toAEP:NRC:0969AA BACKGROUND INFORMATION ANDKJSTIFICATZON FORTHEUSEOFCODECASEN-524ASANALTERNATIVE FORTHEEXAMZHATION REQUIREMENTS FORLONGITUDINAL WELDSZNCLASS1AND2PIPINGFORCOOKNUCLEARPLANTUNITS1AND2THIRD10-YEARINTERVAL Attachment 4toAEP:NRC:0969AA Page1IZ.System/Component forwhichreliefisrequested Class1and2longitudinal weldsinpiping.CodeRequirements TableIWB-2500-1, examination categoryB-J,itemsB9.12andB9.22,andtableIWC-2500-1, examination categories C-F-1andC-F-2ofASMESectionXIcode,1989editionwithnoaddenda,requirevolumetric and/orsurfaceexamination fromtheintersection oflongitudinal andcircumferential weldsforadistanceofonepipediameterinlengthbutnogreaterthanonefootmaximumforclass1weldsandtwoandone-halftimesthepipewallthickness forclass2welds.IIZ.BasisforcodereliefZV.The1989editionofASMESectionXIcoderequirestheexamination oflongitudinal class1and2pipingweldsbeinaccordance withtherequirements oftablesIWB-2500-1 andIWC-2500-1.
Thelengthofweldexaminedshallbeonepipediameterbutnogreaterthanonefootmaximumforclass1weldsandtwoandone-halftimesthewallthickness forclass2welds.Class1and2longitudinal pipingweldsdoexistin~ariousCookNuclearPlantsystems.CodeCaseN-524providesanacceptable alternative thatexaminestheintersectional areaofcircumferential andlongitudinal welds,whichistheareamostpronetofailure.Thispositionisfurthersupported bytheapprovalofCodeCaseN-524bytheASMESectionXIorganization asanacceptable alternative tothecodeexamination ofclass1and2longitudinal pipingwelds.Alternative MethodV.Asanalternative totherequirements ofthe1989editionoftheASMESectionXIcode,itisproposedtoexamineclass1and2longitudinal pipingweldsinaccordance withtherequirements statedinASMECodeCaseN-524.Justification forgrantingcodereliefCodeCaseN-524wasapprovedbytheASMESectionXIcodeorganization fortheexamination ofclass1and2longitudinal pipeweldsasanalternate methodtothecodeexamination.
Thiscodecaseacceptsthecodeexamination ofthecircumferential weldvolumeassufficient indetermining theintegrity oftheintersection ofcircumferential andlongitudinal welds.Theintersection ofthelongitudinal andcircumferential weldsisexpectedtopossessthehighestresidualstressesofthecollective weldduetothemanufacturing processandtherefore, athoroughcodeexamination ofthecircumferential weldvolumewouldbeadequateindetermining theintegrity ofthisarea.Additionally, therehavebeennoreportedfailuresintheindustry, wherethefailurewasinitiated outsidetheintersection areathatwouldbeexaminedduringtheultrasonic testingofthecircumferential weld.
Attachment 4toAEP:NRC:0969AA Page2Theimplementation ofthiscodecasewillsignificantly reducelaborandradiation exposureduetodecreased scaffolding installation andinsulation removalforvisualaccesstothelongitudinal welds,.Theuseofthiscodecaseprovidesanacceptable alternative tothecurrentcodemethodofexamining class1and2longitudinal pipingweldswhileproviding anacceptable levelofqualityandsafety.
e'd}}
e'd}}

Revision as of 06:54, 6 July 2018

Forwards RAI Re Requests for Relief from Code Cases N-521, N-491,N-509 & N-524
ML17333A636
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 11/07/1996
From: FITZPATRICK E
AMERICAN ELECTRIC POWER CO., INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
AEP:NRC:0969AA, AEP:NRC:969AA, TAC-M94871, TAC-M94872, NUDOCS 9611150063
Download: ML17333A636 (17)


Text

1~h r CATEGORY j.REGULATC INFORMATION DISTRIBUTIONSTEM (RIDE)ACCESSION NBR:9611150063 DOC.DATE: 96/11/07 NOTARIZED:

NO FACIL:50-315 Donald.C.Cook Nuclear Power Plant, Unit 1, indiana M 50-316 Donald C.Cook Nuclear Power Plant, Unit 2, Indiana M AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.E American Electric Power Co., Inc.RECIP.NAME RECIPIENT AFFILIATION Document.Control Branch (Document Control Desk)DOCKET 05000315 05000316

SUBJECT:

Forwards RAI re requests for relief to Code Cases N-521, N-491,N-509 6 N-524.r DISTRIBUTION CODE: A047D COPIES RECEIVED'LTR L ENCL SIZE: II TITLE: OR Submittal:

lnservice/Testing/Relief from ASM Code-GL-9-04 NOTES: T E RECIPIENT ID CODE/NAME PD3-3 LA HICKMANFJ INTERNAL: AEOD/SPD/RAB NRR/DE/EMEB OGC/HDS2 RES/DSIR/EIB COPIES LTTR ENCL 1 1 1 1-1 1 1 1 1 0 1 1 RECIPIENT ID CODE/NAME PD3-3 PD E CENTER 1 NUDOCS-A TRACT RES/DET/EMMEB COPIES LTTR ENCL 1 1 1 1 1 1 1 1 0 EXTERNAL: LITCO ANDERSON NRC PDR 1 1 NOAC 1 1 1 1 D 0 E N NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE.TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 13 ENCL 12 American Electric P~er Nuclear Generation+p 500 Circle Drive Buchanan, MI 491071395 November 7, 1996 Docket Nos.: 50-315 50-316 U.S.Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.20555 Gentlemen:

ANMICIN tFI.KCfRIC POWM AEP:NRC:0969AA Donald C.Cook Nuclear Plant Units 1 and 2 THIRD 10-YEAR INTBRVAL INSERVICE INSPECTION PROGRAM AND ASSOCIATED REQUESTS FOR RELIEF (TAC NOS.M94871 AND M94872)REQUEST FOR ADDITIONAL INFORMATION References Letter AEP:NRC:0969AW, E.E.Fitzpatri,ck to U.S.NRC,"Donald C.Cook Nuclear Plant Units 1 and 2, THIRD 10-YEAR INTERVAL INSERVICB INSPECTION PROGRAM AND ASSOCIATED REQUESTS FOR RELIEF (TAC NOS.M94871 AND M94872), REQUEST FOR ADDITIONAL INFORMATION" dated, September 10, 1996.2.Letter, C.A.Carpenter to E.E.Fitzpatrick,"D.C.COOK, UNITS 1 AND 2, REQUESTING APPROVAL OF CODE CASE N-498-1 AS AN ALTERNATIVE TO THB REQUIRED HYDROSTATIC PRESSURE TEST (TAC NOS.M91783 AND M91784)", dated July 5, 1995.The third 10-year inservice inspection plan for Cook Nuclear Plant utilizes code cases that have not been incorporated into Regulatory Guide 1.147.Because of this, NRC approval of the use of these code cases as alternatives to the ASME Section XI requirements is required, The particular code cases for which approval is required were identified in our September 10, 1996, letter (reference 1).The attachments to this letter provide relief requests that would allow Cook Nuclear Plant to use Code Cases N-521, N-491-1, N-509, and N-524 as alternatives to the requirements of the 1989 edition of ASME Code Section XI.Please note that although Code Case N-498-1 was identified in reference 1, this letter does not contain a relief request for use of this code case because we previously obtained approval for its use (reference 2).Approval of these requests is required by July 1, 1997.E.E.Fitzpatrick Vice President Attachments h 9'6ii150063 961107~i.PDR).ADOCK 050003i5: 6'~PORE li U.S.Nuclear Regulatory Commission Page 2 AEP:NRC:0969AA cc: A.A.Blind A.B.Beach MDEQ-DW&RPD NRC Resident Inspector J.R.Padgett Attachment 1 to AEP:NRC:0969AA BACKGROUND INPORMATION AND JUSTIFICATION TO USE CODE CASE N-521 AS AN ALTERNATIVE POR THE EXAMINATION OP NOZZLE TO VESSEL AND SAFE END WELDS AND INSIDE RADIUS SECTIONS POR THE COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10" YEAR INTERVAL

Attachment-1 to AEP:NRC:0969AA Page 1 System/Component for which relief is requested Nozzle to vessel welds, nozzle inside radius sections, and'nozzle to safe end welds for Cook Nuclear Plant, units 1 and 2.lZ.Code Requirements Examination categories B-D and B-F, items B3.90 and B3.100 of ASME Section XI code, 1989 edition with no addenda, require 100~volumetric examination per IWA-2500-7 of at least 25~but not more than 50%of reactor vessel nozzle to vessel welds and nozzle inside radius sections by the end of the first period.Examination category B-F, item 5.10 requires 100%surface and volumetric examination per figure IWB-2500-8 of dissimilar metal nozzle to safe end welds that may be examined coincident with the vessel nozzle examinations.

ZZI.Basis for code relief The ASME Section XI code requirements for the examination of reactor pressure vessel nozzle to vessel welds, the nozzle inside radius sections, and nozzle to safe end welds stipulate a distribution of these examinations in at least two of the three periods.The same sequence established in the first 10-year interval must be used for successive 10-year intervals.

The implementation of these code requirements would result in an additional set-up of the automated ultrasonic (UT)equipment used to examine the nozzle to vessel welds, inside radius sections, and nozzle to safe end welds.Additionally, personnel radiation exposure would increase due to the additional set-up of automated UT equipment and support hours needed to perform this examination.

This position is further supported by the following.

Code Case N-521 issued by the ASME Section XI organization provides an acceptable alternative to the code method for the examination of the nozzle to vessel and safe end welds, and inside radius sections.This code relief was approved for use for the V.C.Summer Nuclear Plant, for the second 10-year interval (reference 1).Alternative Method As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform all the nozzle to vessel, nozzle to safe end welds, and inside radius section examinations in the third period of the third interval.V.Justification for granting code relief Code Case N-521 imposes the following conditions that must be met prior to its use:

Attachment 1 to AEP:NRC:0969AA Page 2 no inservice repairs or replacements by welding have been performed on the nozzle to vessel and safe end welds, or inside radius section;the nozzle to vessel and safe end welds and the inside radius section examination volume shall not contain flaws that require successive examinations in accordance with ZWA-2420(b);

and the unit is not in the first 10-year interval.Cook Nuclear Plant has not performed inservice repairs or replacements on the nozzle to vessel and safe end welds, and inside radius sections.Flaws have not been identified in the examination volume that require successive examinations and both units 1 and 2 are in the third 10-year interval;therefore, applicability of this code case has been met.The deferral of all examinations to the third period of the third 10-year interval will result in reduced set-up hours and personnel radiation exposure hours due to consolidation of manpower efforts (set-up and support)to the third period of the third 10-year interval.The examination of nozzle to vessel welds from the shell side was performed for units 1 and 2 in the third period of the second 10-year interval during the 1995 and 1996 refueling outages.Examination of nozzle to vessel welds from the bore inside diameter (four for unit 1 and two for unit 2)were performed in the first period to meet code requ'rements.

The second 10-year interval examination of the inside radius sections and nozzle to safe end welds was performed in accordance with table ZWA-2500-1 of the code (at least 25%but not more than 50%in the first period and the balance of 100%in the third period).Four of the eight inside radius sections and nozzle to safe end welds were performed in the third period (1995)of the second 10-year interval for unit 1.Six of eight inside radius sections and nozzle to safe end weld'or unit 2 were examined in 1996.Because we performed a majority of the examinations in the third period of the second 10-year interval, and there were no flaws detected in any of the examinations conducted in the first or second intervals, it is reasonable to conclude that the deferment of all the examinations to the third period of the third 10-year interval will not compromise the safety of plant personnel or equipment.

The alternate test using Code Case N-521 eliminates the hardship of performing two automated examinations per inspection interval while providing an acceptable level of quality and safety for Cook Nuclear Plant.VZ.Reference Letter, F.J.Hebdon to G.J.Taylor,"Evaluation of Relief Requests for RR-07 and IWA-5242(a), Virgil C.Summer Nuclear Station (TAC Nos.M94363 and M94364)," dated April 11, 1996.

Attachment 2 to AEP:NRC:0969AA BACKGROUND INFORMATION AND JUSTIFICATION TO USE CODE CASE N-491-1 AS AN ALTERNATIVE FOR THE ZNSPECTZON OF CLASS 1, 2, 3, AND MC COMPONENT SUPPORTS FOR COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10-YEAR INTERVAL Attachment 2 to AEP:NRC:0969AA Page 1 System/Component for which, relief is requested Class 1, 2, 3, and MC component supports.Code Requirements Table IWF-2500-1, examination category F-A, items F1.10 through F1.70 of the 1989 edition of ASME Section XI code, requires visual and VT-3 examination of class 1, 2, and 3'upports in accordance with the schedule established for components under IWB, IWC, IWD and IWE.III.Basis for code relief The 1989 edition of the ASME Section XI code requires the examination of component supports be based on a frequency in accordance with the IWB, IWC, IWD, and IWE components for each interval.The proposed al"ernative method to be used by Cook Nuclear Plant and outlined in ASME Code Case N-491-1 provides a selection criteria based on applying a reasonable percentage of examinations for each class of component supports.Significant personnel radiation exposure and contamination savings are predicted to result from the implementation of these requirements compared with the requirements stated in the 1989 edition of the ASME Section XI code.IV.Code Case N-491-1 was approved by the ASME Section XI organization in April 1993, and provides an acceptable alternative to the code method for the examination of component supports.Alternative Method V.As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform examination of component supports in accordance with the requirements established in ASME approved Code Case N-491-1.Justification for granting code relief The ASME Section XI code organization has approved the use of Code Case N-491-1 as an acceptable alternative'o the code requirements for the examination of component supports.Piping systems are examined frequently during plant walkdowns with thy units operating or during planned or unplanned outages.If the failure or degradation of a support is observed during these walkdowns, whether they are formal visual/VT-3 examinations or informal observations, prompt action is taken including the evaluation, repair, and/or replacement of"supports.

The use of the proposed alternative for the inspection and examination of component supports will result in significant labor and dose savings while providing an acceptable level of quality and safety.

Attachment 3 to AEPsNRCs0969AA BACKGROUND INFORMATION AND JUSTZPICATION TO USE CODE CASE N-509 AS ALTERNATIVE RULES POR THE SELECTZON AND INSPECTION OP CLASS 1, 2, and 3 INTEGRALLY WELDED ATTACHMENTS POR COOK NUCLEAR PLANT UNITS 1 and 2 THIRD 10-YEAR INTERVAL r

Attachment 3 to AEP:NRC:0969AA Page 1 System/Component for which relief is requested Class 1, 2, and 3 integrally welded attachments.

Code Requirements Table IWB-2500-1, examination categories B-H and B-K-1;table IWC-2500-1, examination category C-C;and table IWD-2500-1, examination'ategories D-A, D-B, and D-C of the 1989 edition of ASME Section XI code require surface or volumetric examination for welded attachments of vessels, piping, pumps, and valves.III.Basis for code relief The 1989 edition of the ASME Section XI code requires the examination of integrally welded attachments to be based on the requirements indicated in tables IWB-2500-1 through IWD-2500-1.Frequency and extent of examination are in accordance with these tables and the inspection program chosen by the owner.The proposed alternative method to be used by Cook Nuclear Plant and outlined in ASME Code Case N-509 provides selection criteria based on identified deformation of the component support members found in the plant either during operation, refueling, maintenance, examination, inservice inspection, or testing.The criteria stated in Code Case N-509 are more reasonable than the random examination of all welded attachments in that they focus the examination and the evaluation on those component supports and welded attachments that are susceptible to early failure.Significant personnel radiation exposure and contamination savings are predicted to result from the implementation of these requirements.

Code Case N-509 was approved in November 1992 by the ASME Section XI organization and provides an acceptable alternative to the code method for the examination of welded attachments for vessels, piping, pumps, and valves.IV.'lternative Method As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to perform examination of welded attachments for vessels, piping, pumps, and valves in accordance with Code Case N-509.V.Justification for granting code relief The ASME Section XI code organization has approved the use of Code Case N-509 as an acceptable alternative,to the code requirements for the examination of welded attachments for vessels, piping, pumps, and valves.Component supports are examined frequently during plant walkdowns, both with the units operating or during planned or unplanned outages.If a failure or deformation of a component support is observed during these walkdowns, a surface examination of the appropriate boundary of the welded Attachment 3 to AEP:NRC:0969AA Page 2 attachment shall be performed in accordance with Code Case N-509.This examination strategy is more reasonable than the code method of random examination of welded attachments due to its focus on higher stressed component supports that would be more susceptible to failure in the attachment weld.The use of the proposed alternative for the inspection and examination of welded attachments will result in significant labor and dose savings while providing an acceptable level of quality and safety.

Attachment 4 to AEP:NRC:0969AA BACKGROUND INFORMATION AND KJSTIFICATZON FOR THE USE OF CODE CASE N-524 AS AN ALTERNATIVE FOR THE EXAMZHATION REQUIREMENTS FOR LONGITUDINAL WELDS ZN CLASS 1 AND 2 PIPING FOR COOK NUCLEAR PLANT UNITS 1 AND 2 THIRD 10-YEAR INTERVAL Attachment 4 to AEP:NRC:0969AA Page 1 IZ.System/Component for which relief is requested Class 1 and 2 longitudinal welds in piping.Code Requirements Table IWB-2500-1, examination category B-J, items B9.12 and B9.22, and table IWC-2500-1, examination categories C-F-1 and C-F-2 of ASME Section XI code, 1989 edition with no addenda, require volumetric and/or surface examination from the intersection of longitudinal and circumferential welds for a distance of one pipe diameter in length but no greater than one foot maximum for class 1 welds and two and one-half times the pipe wall thickness for class 2 welds.IIZ.Basis for code relief ZV.The 1989 edition of ASME Section XI code requires the examination of longitudinal class 1 and 2 piping welds be in accordance with the requirements of tables IWB-2500-1 and IWC-2500-1.

The length of weld examined shall be one pipe diameter but no greater than one foot maximum for class 1 welds and two and one-half times the wall thickness for class 2 welds.Class 1 and 2 longitudinal piping welds do exist in~arious Cook Nuclear Plant systems.Code Case N-524 provides an acceptable alternative that examines the intersectional area of circumferential and longitudinal welds, which is the area most prone to failure.This position is further supported by the approval of Code Case N-524 by the ASME Section XI organization as an acceptable alternative to the code examination of class 1 and 2 longitudinal piping welds.Alternative Method V.As an alternative to the requirements of the 1989 edition of the ASME Section XI code, it is proposed to examine class 1 and 2 longitudinal piping welds in accordance with the requirements stated in ASME Code Case N-524.Justification for granting code relief Code Case N-524 was approved by the ASME Section XI code organization for the examination of class 1 and 2 longitudinal pipe welds as an alternate method to the code examination.

This code case accepts the code examination of the circumferential weld volume as sufficient in determining the integrity of the intersection of circumferential and longitudinal welds.The intersection of the longitudinal and circumferential welds is expected to possess the highest residual stresses of the collective weld due to the manufacturing process and therefore, a thorough code examination of the circumferential weld volume would be adequate in determining the integrity of this area.Additionally, there have been no reported failures in the industry, where the failure was initiated outside the intersection area that would be examined during the ultrasonic testing of the circumferential weld.

Attachment 4 to AEP:NRC:0969AA Page 2 The implementation of this code case will significantly reduce labor and radiation exposure due to decreased scaffolding installation and insulation removal for visual access to the longitudinal welds,.The use of this code case provides an acceptable alternative to the current code method of examining class 1 and 2 longitudinal piping welds while providing an acceptable level of quality and safety.

e'd