{{#Wiki_filter: | {{#Wiki_filter:Volume10Section01PLANTOPERATIONS MANUALREFERENCE USEEMERGENCY PLANPROCEDURE PERSONNEL INJURYSAFETYRELATED10-8-01-19 Revision: | ||
021Date:5-2-16Prepared: | |||
Reviewed:Mag.ergencylaMingListofEffectivePages: | |||
Pages1-9Attachments I-IIListofTCNsIncorporated:RevisionTCN oNone112-021NoneJ:\ADMLSRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEAR STATIONEMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19RPTSFORMRevision: | |||
021Page:iREQUIREDREVIEWPERFORMED oPADo50.59Screen/Eva!.(Checkallthatapply) | |||
(EN-L1-100) | |||
(EN-L1-101)o72.48Screen/Eva!. | |||
o50.54Eva!.TransmitapplicableReviewFormasa (EN-L1-112) | |||
(EN-NS-210)separaterecordalongwith procedure tooPADNotRequired{EN-L1-100 or01-S-02-3) | |||
DocumentControl.oProcessApplicability ExcludedoEditorial ChangeolSI/1STImplementation oTCNIncorporationorAutoRev. | |||
oOtherProcess-Number:PADReviewer: | |||
/(forPADNot Required) | |||
Signature/Date Cross-Disci linereviewreuired?PrearerInitials>>> | |||
(NoteaffectedDepartments Below)Department Cross-Discipline ReviewsNeededSignoff:(signed, electronic, telcon)Industrial Safety(.,..,."..*...c*. | |||
\"""'--.::J | |||
___Doesthisdirective containTechSpecTriggers?()YES(X)NOREQUIREMENTS CROSS-REFERENCE LISTRequirement Implemented byDirective Directive Paragraph NumberNameParagraph NumberThatImplements Requirement GGNSEmergency Plan6.7.3.51,52 | |||
&6.7.4.S56.3(Note)&6.4.110CFR5072.B.3.XII 6.3(Caution) | |||
*Coveredby directiveasawholeorbyvarious paragraphsofthedirective. | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEARSTATION EMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19Revision:021Page:ii TheEquipment Database(EDB)Requeststatement isapplicableonlytoVolume06and07 maintenance directives.EDBChange Requestgeneratedandthebackup documentation available forsetpointand/orcalibrationdataonly DYesDN/AEDBCR#_CurrentRevision StatementRevision021:*Addreference toManagement Standard#20-OperatingHard-Card,ControlRoomActionsforMedicalEmergency. | |||
(Reference CR-GGN-2016-2247CA#2)*Changestoreporting emergenciesandControlRoomactionstobe consistent withManagementStandard#20. | |||
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.DOC I'Page:1EMERGENCY PLANPROCEDURE IReVISion: | |||
021GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 | |||
'--------------- | |||
TABLEOFCONTENTS' Page1.0PURPOSEANDDISCUSSION 22.0RESPONSIBILITIES | |||
==23.0REFERENCES== | ==23.0REFERENCES== | ||
34. | |||
34.0ATTACHMENTS 35.0DEFINITIONS 36.0DETAILS46.1Reporting ofInjuries46.2Immediate Actions56.3Ambulance Transport 66.4OffsiteMedicalFacilities 86.5HospitalPreparation toReceivePatients9J:\ADM_SRVS\TECH_PGB\lO\lOSOl19. | |||
DOC GRANDGULF NUCLEARSTATIONITitle:Personnel Injury1.0PURPOSEANDDISCUSSION 1.1PurposeINo.:1o-s-01-19 EMERGENCY PLANPROCEDURE1.1.1Toprovideguidanceonresponseto,reportingof,andtransferofinjured personnel underthefollowing conditions:a.Injuredperson requiring transporttoanoffsitemedicalcarefacilityb.Anyinjuriesdiscovered duringanemergency classification 1.2Discussion1.2.1Byagreement betweenEntergyOperations,Inc.andthe primaryandbackup.medicalcarefacilities, personnelattheGrand GulfNuclearStationsustaining injuriesfromionizingradiation orinjuriescomplicated byradiation exposureorradioactive contaminationaretobeprovidedcareandtreatment atthosefacilities. | |||
Procedures andequipmentforthiscareand treatment aremaintained atthesefacilities. | |||
Anindividual whoseclothing, skinand/orwoundsarecontaminated withradioactive materialmaypresentaradiation hazardtoattending personnelintheabsenceofadequateprocedures topreventthespreadofthecontaminant, orcontrolthe radiation exposureintheeventofradioactive shrapnelwound.Sinceradiation injuriesarenotimmediately life-threatening, primaryattention shouldalwaysbedirectedtotraumatic life-threatening injuries. | |||
Aftersuchtreatment isrendered, thepatientshouldbedecontaminated. | |||
2.0RESPONSIBILITIES2.1TheManager.Radiation Protection-IsresponsiblefortheimplementationoftheFirstAid ProgramatGGNS.2.2TheRadiation Protection Supervisor-Isresponsiblefortheadministration andmanagementoftheFirstAid Programincluding:2.2.1TheassignmentofaFirstAid qualified individualtoeachRadiation Protection shift.2.2.2Maintenanceoffirstaid suppliesandmedicalemergency responseequipment. | |||
2.2.3Transportation ofinjuredpersonneltothehospitalandcontamination controlmeasuresasnecessary. | |||
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19. | |||
DOC GRANDGULFNUCLEARSTATIONITitle:Personnel InjuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IReVISion: | |||
0212.3AllGGNSpersonnel-Are toimmediately reportobservedseriousinjuriestotheControlRoom.Personnel withintheProtected Arearequiring minorfirstaidaretoreporttoRadiation Protection formedicaltreatment. | |||
2.4TheOSCManager-Isresponsible fororganizing anddispatchingofFirstAid TeamsperEN-EP-611 whentheOSCisoperational. | |||
2.5TheEOFPublicInformation Liaison-Isresponsible fornotifying theCompanySpokesperson regarding workerinjuriesduringadeclaredemergency. | |||
==3.0REFERENCES== | ==3.0REFERENCES== | ||
3. | |||
3.1Corporate Procedure EN-IS-113, Reporting | |||
&Investigating Occupational Injuries/Illnesses AndNearMisses3.2GrandGulfNuclearStationemergency PhoneBookSectionE,Fireand MedicalSupport.3.3Management Standard#20,OperatingHardCard-ControlRoomActionsforMedicalEmergency' | |||
==4.0 ATTACHMENTS== | |||
4.1AttachmentI-Directions toClaiborne CountyHospital4.2AttachmentII-Directions toRiverRegionMedicalCenter5.0DEFINITIONS 5.1OSC-Operations SupportCenter5.2TSC-Technical SupportCenter5.3RPS-Radiation Protection Supervisor5.4REA-Radiation Emergency AreaJ:\ADM_SRVS\TECH_PUB\10\10S0119. | |||
DOC GRANDGULFNUCLEARSTATIONEMERGENCYPLANPROCEDURE ITitle:Personnel Injury6.0DETAILS6.1ReportingofInjuries IReVISion: | |||
021IPage:4MaintaincommunicationswiththeControlRoomuntilallreportedinformationisproperly acknowledged.6.1.1Anyindividualfindinganinjuredpersonwhorequiresmajormedicalassistanceistoimmediately NOTIFYtheControlRoombythe quickestavailablemeans.a.Thefollowing informationshouldbeprovidedtotheControlRoom:(1)Nameand locationoftheinjuredperson (2)Natureoftheemergency,ifknown.(3)IsMedical Help/Ambulance needed?(4)Nameofthecaller6.1.2TheControlRoomistoperformthefollowingactions.Ifavailableuse ManagementStandard#20-OperatingHardCardforMedicalEmergency:a.ImmediatelyNOTIFYthe Radiation Protection(RP)LaborSiteMedicalPersonneltodispatchFirstResponderstothescene.b.Ifrequired, ContactAmbulanceforresponsetoGrandGulfNuclearStation.Givethemthelocationoftheemergency.ProvideaCallBackNumberandsiteaddress;7003BaldHillRoad,PortGibson,MississippiTIME:_c.ContactSecurityIslandof Ambulanceresponseandauthorizeentry,as needed.d.HaveSecurity dispatchedtoscene,asnecessary. | |||
NameTime_e.SOUNDSiteFireAlarm;MAKEPAANNOUNCEMENT: | |||
"MEDICALEMERGENCY ATunnecessarypersonnelstayclearofthearea." | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IRevIsion: | |||
021f.REPEATnotificationevery5minutesuntiltheControlRoomhas confirmationthatthefirstaidteamhasbeenassembledatthescene. | |||
g.DispatchoperatortoscenewithFirstAidTraumaKitandAED.FirstAidTraumaKitandAEDlocationsarelistedon ManagementStandard#20. | |||
h.LContactIndustrialSafety. | |||
NameTime_ContactDutyManager. | |||
NameTime_j.ShiftManagerdeterminereportability,asneeded.6.1.3Ifduringdeclared emergency andemergencyresponsefacilitiesareoperational: | |||
a.NOTIFYtheOSCandprovidethe applicableinformationaboutthelocationoftheworkerandextentofinjuries,ifknown. | |||
b.NOTIFYtheTSCEmergencyPlantManager.6.2ImmediateActions6.2.1Uponreceiving notificationofamedicalemergency:theRPLabshould PERFORMthefollowing NOTE:TheFirstAidTeammaybenotifiedbyGaitronics,plantradioorpagerusingAlphaPagingontheGGNSHomePageunder Processes/Programs (pageFirstAidTeam)a.NotifytheControlRoomifnotalreadynotified. | |||
b.DISPATCHaFirstAidTeamtothesceneofthemedicalemergency.TheFirstAidpersonnelshouldbeequippedwiththefollowing: | |||
(1)FirstAidtraumakit(2)Portableradio(3)Radiological surveyinstruments andpersonnel protective equipment (Le.,respiratoryprotectiondevices,PCs)suitableforthehazardsatthelocationandthenatureoftheeventwhichcausedtheinjury(i.e.,fire,explosion). | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.2.1(continued) | |||
INo.:10-8-01-19EMERGENCYPLANPROCEDURE IRevIsion: | |||
021c.TheFirstAidTeamshouldestablishandmaintaincommunicationswiththeRPLab,ControlRoom,orOSCandprovideperiodicupdates.6.2.2FirstAidpersonnelaretoPERFORMthefollowingactionsatthesceneofthemedicalemergency:a.DETERMINEtheinjuredperson'sphysicalconditionandextentofinjuries.b.ADMINISTERfirstaidnecessarytosustainlifeandtostabilizetheinjured worker.c.MOVEtheinjuredpersontoasafelocationiflife-threateningradiologicalorphysicalhazardsarepresent. | |||
d.lEtheinjuryoccurredinaradiologicallypostedarea,THENperformacontaminationsurveyoftheinjuredworkerandREADtheworker's dosimetry.e.PROVIDEthefollowinginformationtotheRPLaborOSCRadChem Coordinator:RadiationProtection(OSCRadChemCoordinator)mustNotifytheControlRoomandprovidethefollowing information (1)Nameandlocationoftheinjuredperson. | |||
(2)Extentofinjuriesandtreatmentbeingadministered.(3)Personnel contamination surveyanddosimeterresultsfortheinjuredworker.(4)Theneedforanambulanceorotherassistance.f.PREPAREtheinjuredworkerfortransfertothehospital.g.RadiationProtectionpersonnelatthesceneofthemedicalemergencymustPERFORMradiologicalsurveysasnecessarytoprotectteammembersandsupportpersonnel. | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.3Ambulance Transport INo.:10-$-01-19 EMERGENCY PLANPROCEDURE IReVISion: | |||
021The-transportofinjuredpersonsisnormallyprovidedbytheregionalambulanceservice.Iftheregional ambulanceserviceisunavailable,theinjuredpersonshouldbetransportedincompanyownedorprivatevehicle. | |||
CAUTIONIfacontaminated injuredpersonistransported toanoffsitemedicalfacility, theNRCshallbenotifiedwithineighthours,inaccordance with01-5-06-5.6.3.1Ifambulance transportisnecessarythe ControlRoomshouldusethephonenumberslistedinReference3.2 torequestanambulance.a.Informthe ambulanceofthelocationoftheinjured,accesspointor anyotherinformationnecessary.6.3.2TheControlRoommustNOTIFYSecurityifanOnsiteorOffsite ambulance isrequiredtoentertheprotectedareaandmust SPECIFYthepatientpickuppoint.a.TheSecurity Coordinator mustENSUREthatOffsite ambulancecrewsareissueddosimetryattheentrancetotheProtectedArea.b.RadiationProtectionpersonnelatthesceneofthemedical emergency mustENSUREthatOffsiteambulancecrewmembersareproperlywearing theappropriate dosimetryandprotectiveclothingforentryinto radiologicallycontrolledareas.6.3.3TheShiftManagershouldNOTIFYtheEOFEmergency DirectorandINFORMhimofthetransportation ofaninjuredcontaminatedworkertothehospital.Thehospital.mustreceivethisinformationassoonaspossibleinordertomakethenecessary preparationsfortheemergency treatmentoftheworker.ThehospitalphonenumbersarelistedintheEmergencyTelephoneBook. | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCYPLANPROCEDURE IPage:86.3.4TheRPSupervisor/Shift leadHP(OSCRadChern Coordinator) receiving theinitialinformation mustnotifythehospitalandprovidethefollowing information assoonaspossible. | |||
a.Nameofinjuredworker(s) b.Extentofinjuries c.Contaminationlevelsoninjuredworker(s),ifapplicabled.Expected arrivaltimeathospital,ifknown.6.3.5GGNSpersonnelshould PERFORMthefollowingenroutetothehospital:*AfriskerisnormallymaintainedintheOnsiteAmbulance*Surveysmaybelimitedorimpracticalduetotheextentofinjuriesreceivedbytheworker. | |||
a.PERFORMadetailedcontamination surveyoftheinjuredworkeriftheinjuryoccurredina RadiologicallyControlledArea.6.4OffsiteMedicalFacilities6.4.1TheRadiationProtection Supervisor/ShiftLeadHP(OSCRadChem Coordinator) isresponsible fordeterminingwhichmedicalfacilitytouse.Facilitiesavailableforuseinclude:a.ClaiborneCountyHospitalb.RiverRegionMedicalCenter 6.4.2AttachmentIandIIareusedto determine transportationroutestothemedical facilities. | |||
J:\AOM_SRVS\TECH_PUB\lO\lOSOl19:00C GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19EMERGENCYPLANPROCEDURE IPage:96.4.3Processforselectinghospitalfacilitiesduringnon-radiologicalemergenciesis:a.Non-contaminated,non-lifethreatening:RiverRegionMedicalCenter,orClaiborneCountyHospital.StreetClinicinVicksburgisrecommendedwhereapplicable.b.Non-contaminated,lifethreatening-transporttoClaiborneCounty Hospital.c.PlantSafetyandEMTpersonnelmayalsoauthorizehospitallocationsduringnon-radiologicalemergenciesusingtheguidelinesabove.6.4.4Contaminatedpersonnelwithminorormajorinjuriesshouldbetransportedtooneofthemedicalfacilitiesidentifiedin6.4.1.6.4.5Patientsmustbedeliveredtohospitalfacilitiesasfollows:a.AllinjuredworkerswhoarenotcontaminatedshouldbetransporteddirectlytothehospitalEmergencyRoom.b.Contaminatedpersonnelshouldbetransportedtothehospital Radiation Emergency Area.6.4.6Whenacontaminatedinjuredworkeristransportedtothehospital,GGNSpersonnelatthehospitalshouldprovidethefollowingsupport,ifavailable:a.PROVIDEthephysicianwithallavailableinformationconcerningtheaccidentandthecontaminationhazardspresent,uponrequest. | |||
b.ASSISTthehospitalstaff,ifpossible. | |||
.c,COORDINATEthecollectionanddisposalofcontaminatedwaste materials. | |||
d.COLLECTOffsiteambulancecrewdosimetryandPERFORMcontaminationsurveyofambulance. | |||
ARRANGEfordecontamination,if necessary.6.5HospitalPreparationtoReceivePatients6.5.1ThehospitalroomREA(RadiationEmergencyArea)isnormallysetupby hospitalp.ersonnelbeforethearrivalofthepatient. | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULF NUCLEARSTATIONEMERGENCY PLANPROCEDURE 10-S-01-19 Attachment IRevision:021Page1of1DIRECTIONS TOCLAIBORNE COUNTYHOSPITALG,:G1NSI{GrandGulfRoad DIRECTIONS:TakeHwy61Sto McCombAvenue(StateRoad547).GoEaston547andthehospitalisonyourleft.The entrancetotheRadiation EmergencyAreaisthroughthe Emergency RoomEntranceontheNorthendofthe hospitalJ:\ADM_SRVS\TECH_PUB\10\10S0119.DOC IIIIIII IIIPort:GibsonII IIIIHWY462HWY18III:Claiborne:CountyIHospitalo.llmAve GRANDGULF NUCLEARSTATION.EMERGENCY PLANPROCEDURE 10-S-01-19Revision:021 Attachment IIPage1of1DIRECTIONSTORIVERREGION MEDICALCENTERTakeUS61Northpast CulkinAve.Youwillseethe hospitalonyourright.The Emergency RoomentranceisontheSouthsideofthehospital. | |||
ThedoortotheDecontaminationRoomistothe rightoftheER.entrance. | |||
RiverRegion.A.-f---- | |||
MedicalCenter | |||
---.\DIRECTIONS: | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC ATTACHMENT 9.1SHEET1OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartI.Description ofActivityBeingReviewed(eventoraction,orseriesofactionsthatmayresultinachangetotheemergencyplanoraffecttheimplementationoftheemergencyplan): | |||
Revision021:1.Changestoreporting emergencies andControlRoomactionstobeconsistent withManagement Standard#20.2.AddedMedicalFacility/Site Nursetosection2.3asanoptionforpersonnel requiring minorfirstaid,sincethisfacility/position ismannedduringoutages.3.AddedPlantOccupational HealthNursetosection6.4.3listofpersonnel whomayauthorize hospitalfacilities totransport patientsto.Editorial Changes:4.Addreference toManagement Standard#20-Operating Hard-Card, ControlRoomActionsforMedicalEmergency. | |||
(Reference CR-GGN-2016-2247 CA#2)5.ChangedthetitleRiverRegionHospitaltoMeritHealthRiverRegionduetoachangeinthefacilityname.PartII.ActivityPreviously Reviewed?IsthisactivityfullyboundedbyanNRCapproved10CFR50.90submittal orAlertandNotification SystemDesignReport?IfYES,identifyboundingsourcedocumentnumber/approval reference andensurethebasisforconcluding thesourcedocumentfullyboundstheproposedchangeisdocumented below:Justification: | |||
DBoundingdocumentattached(optional) | |||
DYES50.54(q)(3) | |||
Evaluation isNOTrequired. | |||
Enterjustification belowandcompletePartVI.t81NOContinuetonextpartPartIII.Applicability ofOtherRegulatory ChangeControlProcessesCheckifanyotherregulatorychangeprocessescontroltheproposed activity.(RefertoEN-L1-100)NOTE:Forexample,whenadesignchangeistheproposedactivity,consequentialactionsmayincludechangestootherdocumentswhichhaveadifferentchangecontrolprocessandareNOTtobeincludedinthis50.54(q)(3) | |||
Screening. | |||
APPLICABILITY CONCLUSIONIftherearenocontrollingchangeprocesses,continuethe50.54(q)(3)Screening. | |||
DOneormorecontrollingchangeprocessesareselected,however,someportionoftheactivityinvolvestheemergencyplanoraffectstheimplementationoftheemergencyplan;continuethe50.54(q)(3)Screeningforthatportionoftheactivity.Identifytheapplicablecontrollingchangeprocessesbelow. | |||
oOneormorecontrollingchangeprocessesareselectedandfullyboundsallaspectsoftheactivity. | |||
50.54(q)(3) | |||
Evaluation isNOTrequired.IdentifycontrollingchangeprocessesbelowandcompletePart VI.CONTROLLINGCHANGEPROCESSES EN-EP-305 REV3 ATTACHMENT 9.1SHEET2OF510CFR50.54(q), | |||
SCREENING Procedure/Document Number:10-5-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartIV.Editorial ChangeDYESt8JNO50.54(q)(3)ContinuetonextIsthisactivityaneditorialortypographicalchangesuchasformatting,paragraph Evaluation ispartnumbering,spelling,orpunctuationthatdoesnotchangeintent? | |||
NOTrequired. | |||
Justification: | |||
Changes#4&5arereferencechangesandareconsiderededitorial EnterjustificationandchangesaccordingtoEN-EP-305andEN-AD-101.NoischeckedattherightbecausecompleteParttheremainingchangesarenon-editorial. | |||
VI.PartV.Emergency PlanningElement/Function Screen(Associated10CFR50.47(b)planningstandardfunctionidentifiedinbrackets)Doesthisactivityaffectanyofthefollowing,includingprogramelementsfromNUREG-0654/FEMAREP-1SectionI/? | |||
1.Responsibility foremergency responseisassigned. | |||
[1]D2.Theresponseorganizationhasthestaffto respondandtoaugmentstaffonacontinuingbasis(24/7 Dstaffing) inaccordancewiththeemergencyplan.[1]3.Theprocessensuresthatonshiftemergency responseresponsibilities arestaffedandassigned.[2] | |||
D4.Theprocessfortimelyaugmentation ofonshiftstaffisestablished andmaintained. | |||
[2]D5.Arrangements forrequestingandusingoffsiteassistancehavebeenmade.[3] | |||
D6.StateandlocalstaffcanbeaccommodatedattheEOFin accordancewiththeemergencyplan.[3]DI7.Astandardschemeofemergency classificationandactionlevelsisinuse.[4] | |||
D8.Procedures fornotificationofStateandlocal governmental agenciesarecapableofalertingthemof Dthedeclaredemergency within15minutesafterdeclarationofanemergency andproviding follow-upnotifications. | |||
[5]9.Administrative andphysicalmeanshavebeenestablished foralertingandproviding promptDinstructionstothepublicwithintheplume exposurepathway.[5]10.ThepublicANSmeetsthedesignrequirements ofFEMA-REP-10,GuideforEvaluationofAlertand DNotification SystemsforNuclearPowerPlants,orcomplieswiththelicensee's FEMA-approved ANSdesignreportandsupporting FEMAapprovalletter.[5] | |||
11.Systemsareestablished forpromptcommunication amongprincipal emergency responseDorganizations. | |||
[6],12.Systemsareestablished forpromptcommunication toemergency responsepersonnel. | |||
[6]D13.Emergency preparedness information ismadeavailabletothepubliconaperiodicbasiswithinthe 0plumeexposurepathwayemergency planningzone(EPZ).[7] | |||
14.Coordinated dissemination ofpublicinformation duringemergencies isestablished. | |||
[7]*015.Adequatefacinties aremaintained tosupportemergency response. | |||
[8]D16.Adequateequipment ismaintained tosupportemergency response. | |||
[8]D17.Methods,systems,andequipment forassessment ofradioactive releasesareinuse.[9] | |||
D18.Arangeof publicPARsisavailable forimplementation duringemergencies. | |||
[10]D19.Evacuation timeestimatesforthepopulation locatedintheplume exposurepathwayEPZareDavailable tosupporttheformulationofPARsandhavebeen providedtoStateandlocal governmental authorities. | |||
[10]20.Arangeofprotective actionsisavailable forplantemergency workersduringemergencies, including Dthoseforhostileactionevents.[10] | |||
EN-EP-305 REV3 ATTACHMENT 9.1SHEET3OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel Injury21.Theresources forcontrolling radiological exposures foremergency workersareestablished. | |||
[11]D22.Arrangements aremadeformedicalservicesforcontaminated, injuredindividuals. | |||
[12]D23.Plansfor recoveryandreentryaredeveloped. | |||
[13]D24.Adrilland exerciseprogram(inclUding radiological, medical,healthphysicsandotherprogramDareas)isestablished. | |||
[14]25.Drills, exercises, andtrainingevolutions thatprovideperformance opportunities todevelop,Dmaintain, anddemonstratekeyskillsare assessedviaaformal critiqueprocessinordertoidentifyweaknesses. | |||
[14]26.Identified weaknesses arecorrected. | |||
[14]D27.Trainingisprovidedtoemergency responders. | |||
[15]D28.Responsibility foremergency plandevelopment andreviewisestablished. | |||
[16]D29.Plannersresponsible foremergency plandevelopment andmaintenance areproperlytrained.[16]DAPPLICABILITY CONCLUSION aIfnoPartVcriteriaarechecked,a50.54(q)(3)EvaluationisNOTrequired;documentthebasisforconclusionbelowandcompletePartVI. | |||
aIfanyPartVcriteriaarechecked,completePartVIandperforma50.54(q)(3)Evaluation.BASISFORCONCLUSION Changes#4&5areeditorialchangesanddonotrequireevaluation.1.ChangestoreportingemergenciesandControlRoomactionstobeconsistentwithManagementStandard#20.ThischangerevisestheinformationtheControlRoomshouldrequestfromacallerreportingamedical emergencyandaddsadditionalinformationtothestepstakenbytheControlRoomtorespondtotheemergency.Theplanningstandardsandprogramelementsrequirethatmedicalservicesbearrangedforcontaminated,injuredworkersbuttheydonotdescribetheactionstakenbythelicenseetorespondtomedicalemergencies.Thischangedoesnoteliminateanymedicalresponseequipmentorqualificationsanddoesnotaffectoffsite arrangementsformedicalsupportincludingtransportation.Thischangewillnotaffecttheplanningstandardsorprogramelementsin10CFR50.470(b)[12]anddoesnotneedanevaluation. | |||
EN-EP-305REV3 ATTACHMENT 9.1SHEET4OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryBASISFORCONCLUSION (continued) | |||
*AddedMedicalFacility/SiteNursetosection2.3asanoptionforpersonnelrequiringminorfirstaid,sincethis facility/positionismannedduringoutages. | |||
NormallyfirstaidcasesarehandledbyRPpersonnel.Duringoutages,whenwehaveanincreasein workforce, GrandGulfmaysetupasitemedicalfacility and/orstaffasitenursepositionto facilitatetheexpected increaseinfirstaid and/ormedicalemergencycases.Thisprocedurechangeallows personnelrequiringfirstaidtoreporttothesite medicalfacilityorsitenurse,ifstaffed,ratherthanlimitingthemtoreporttotheRP department. | |||
.*Theplanningstandardsandprogramelementsin 10CFR50.47(b)[10]requirearangeof protective actionsbeavailableforplantworkers,butdoesnotspecifythelocationorstaffingofsitefirstaid stationsormedicalfacilitiessothischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].*Thischangedoesnotreducethe numberoffirstaidqualified personnelanddoesnotreducetheshiftstaffingasrequiredin 10CFRS0.47(b)[2]orNUREG06s4tableB-1.thischangewillnotaffectthesitesabilitytomeetthe requirementsof1OCFRS0.47(b)[2].*Thischangedoesnotreducethe amountorlocationofmedical equipmentandsuppliesandwillnot affectthesitesabilitytomeetthe requirements of10CFR50.47(b)[8].*Thischangedoesnotaffectthe arrangementsinplaceformedicalservicesforcontaminatedand injuredindividualsandwillnotaffectthesitesabilitytomeetthe requirementsof10CFRS0.47(b)[12]. | |||
Thischangewillnotaffectanyoftheplanningstandardsorprogram elementsin1OCFR50.470(b)anddoes notrequireanevaluation. | |||
*AddedPlantOccupationalHealthNursetosectionlistofpersonnelwhomayauthorizewhich hospitalfacilitiestowhichpatientsaretransported. | |||
Section6.1.3of10-S-01-19 describestheprocessforselectinq hospitals duringnon-radiological emergenciesandliststhemedical facilitiespersonnelshouldbe transported tolife-threateningorlife-threateninginjuries.ThissectionstatesthatPlantSafetyandEMT personnel mayalsoauthorize hospitallocations.Thischangeaddstheplant OccupationalHealthNursetothatgroup.Thissection onlyappliestonon-contaminated individuals. | |||
*10CFR50.47(b)[12]requires licenseestoensurearrangements aremadefor.medical servicesforcontaminated, injuredindividuals. | |||
Thesearrangementswouldincludehospitals andotheroffsitemedicalfacilities. | |||
10-S-01-19liststhesefacilitiesinsection6.4.*1.Thechange beingmadeto10-S-01-19willnotaffectthislistortheprocessfor determiningwhichhospital totransport contaminated individualsto.Thischangewillnotaffectthesitesabilityto meettherequirements of10CFR50.47(b)[12].*Theplanningstandardsandprogram elementsin10CFR50.47(b)[10]requirearangeofprotective actionsbeavailableforplantworkers,butdoesnotspecifythepositionthatshoulddeterminewhat medicalfacilitiestouse.Thischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].Thechangesbeingmadeto 10-8-01-19willnotaffectanyof the10CFR50.47(b)planningstandardsorprogramelements.This changemaybemade withoutpriorNRCapprovalanddoesnotneeda 10CFR50.54q evaluation. | |||
EN-EP-305REV3 ATTACHMENT 9.1SHEET5OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartVI.Signatures:PreparerName(Print) | |||
Date:/:/--.7-RichardVanDen Akker<r:4-21-16i....._(Optional) | |||
ReviewerName(Print) | |||
ReviewerSignature Date:ReviewerName(Print) | |||
ReviewerSignature Date:TomSowdon Cf;4-22-2016NuclearEP ProjectManager.<< | |||
,//"e.-/''tttfJ-'tC4'l'..t:-- | |||
ApproverName(Print) | |||
ApproverSignature Date:--:rI£'P'PEPmanagerordesignee6')2./16//7'EN-EP-305REV3 Volume10Section01PLANTOPERATIONS MANUALREFERENCE USEEMERGENCY PLANPROCEDURE PERSONNEL INJURYSAFETYRELATED10-8-01-19 Revision: | |||
021Date:5-2-16Prepared: | |||
Reviewed:Mag.ergencylaMingListofEffectivePages: | |||
Pages1-9Attachments I-IIListofTCNsIncorporated:RevisionTCN oNone112-021NoneJ:\ADMLSRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEAR STATIONEMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19RPTSFORMRevision: | |||
021Page:iREQUIREDREVIEWPERFORMED oPADo50.59Screen/Eva!.(Checkallthatapply) | |||
(EN-L1-100) | |||
(EN-L1-101)o72.48Screen/Eva!. | |||
o50.54Eva!.TransmitapplicableReviewFormasa (EN-L1-112) | |||
(EN-NS-210)separaterecordalongwith procedure tooPADNotRequired{EN-L1-100 or01-S-02-3) | |||
DocumentControl.oProcessApplicability ExcludedoEditorial ChangeolSI/1STImplementation oTCNIncorporationorAutoRev. | |||
oOtherProcess-Number:PADReviewer: | |||
/(forPADNot Required) | |||
Signature/Date Cross-Disci linereviewreuired?PrearerInitials>>> | |||
(NoteaffectedDepartments Below)Department Cross-Discipline ReviewsNeededSignoff:(signed, electronic, telcon)Industrial Safety(.,..,."..*...c*. | |||
\"""'--.::J | |||
___Doesthisdirective containTechSpecTriggers?()YES(X)NOREQUIREMENTS CROSS-REFERENCE LISTRequirement Implemented byDirective Directive Paragraph NumberNameParagraph NumberThatImplements Requirement GGNSEmergency Plan6.7.3.51,52 | |||
&6.7.4.S56.3(Note)&6.4.110CFR5072.B.3.XII 6.3(Caution) | |||
*Coveredby directiveasawholeorbyvarious paragraphsofthedirective. | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEARSTATION EMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19Revision:021Page:ii TheEquipment Database(EDB)Requeststatement isapplicableonlytoVolume06and07 maintenance directives.EDBChange Requestgeneratedandthebackup documentation available forsetpointand/orcalibrationdataonly DYesDN/AEDBCR#_CurrentRevision StatementRevision021:*Addreference toManagement Standard#20-OperatingHard-Card,ControlRoomActionsforMedicalEmergency. | |||
(Reference CR-GGN-2016-2247CA#2)*Changestoreporting emergenciesandControlRoomactionstobe consistent withManagementStandard#20. | |||
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.DOC I'Page:1EMERGENCY PLANPROCEDURE IReVISion: | |||
021GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 | |||
'--------------- | |||
TABLEOFCONTENTS' Page1.0PURPOSEANDDISCUSSION 22.0RESPONSIBILITIES | |||
==23.0REFERENCES== | ==23.0REFERENCES== | ||
34. | |||
34.0ATTACHMENTS 35.0DEFINITIONS 36.0DETAILS46.1Reporting ofInjuries46.2Immediate Actions56.3Ambulance Transport 66.4OffsiteMedicalFacilities 86.5HospitalPreparation toReceivePatients9J:\ADM_SRVS\TECH_PGB\lO\lOSOl19. | |||
DOC GRANDGULF NUCLEARSTATIONITitle:Personnel Injury1.0PURPOSEANDDISCUSSION 1.1PurposeINo.:1o-s-01-19 EMERGENCY PLANPROCEDURE1.1.1Toprovideguidanceonresponseto,reportingof,andtransferofinjured personnel underthefollowing conditions:a.Injuredperson requiring transporttoanoffsitemedicalcarefacilityb.Anyinjuriesdiscovered duringanemergency classification 1.2Discussion1.2.1Byagreement betweenEntergyOperations,Inc.andthe primaryandbackup.medicalcarefacilities, personnelattheGrand GulfNuclearStationsustaining injuriesfromionizingradiation orinjuriescomplicated byradiation exposureorradioactive contaminationaretobeprovidedcareandtreatment atthosefacilities. | |||
Procedures andequipmentforthiscareand treatment aremaintained atthesefacilities. | |||
Anindividual whoseclothing, skinand/orwoundsarecontaminated withradioactive materialmaypresentaradiation hazardtoattending personnelintheabsenceofadequateprocedures topreventthespreadofthecontaminant, orcontrolthe radiation exposureintheeventofradioactive shrapnelwound.Sinceradiation injuriesarenotimmediately life-threatening, primaryattention shouldalwaysbedirectedtotraumatic life-threatening injuries. | |||
Aftersuchtreatment isrendered, thepatientshouldbedecontaminated. | |||
2.0RESPONSIBILITIES2.1TheManager.Radiation Protection-IsresponsiblefortheimplementationoftheFirstAid ProgramatGGNS.2.2TheRadiation Protection Supervisor-Isresponsiblefortheadministration andmanagementoftheFirstAid Programincluding:2.2.1TheassignmentofaFirstAid qualified individualtoeachRadiation Protection shift.2.2.2Maintenanceoffirstaid suppliesandmedicalemergency responseequipment. | |||
2.2.3Transportation ofinjuredpersonneltothehospitalandcontamination controlmeasuresasnecessary. | |||
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19. | |||
DOC GRANDGULFNUCLEARSTATIONITitle:Personnel InjuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IReVISion: | |||
0212.3AllGGNSpersonnel-Are toimmediately reportobservedseriousinjuriestotheControlRoom.Personnel withintheProtected Arearequiring minorfirstaidaretoreporttoRadiation Protection formedicaltreatment. | |||
2.4TheOSCManager-Isresponsible fororganizing anddispatchingofFirstAid TeamsperEN-EP-611 whentheOSCisoperational. | |||
2.5TheEOFPublicInformation Liaison-Isresponsible fornotifying theCompanySpokesperson regarding workerinjuriesduringadeclaredemergency. | |||
==3.0REFERENCES== | ==3.0REFERENCES== | ||
3. | |||
3.1Corporate Procedure EN-IS-113, Reporting | |||
&Investigating Occupational Injuries/Illnesses AndNearMisses3.2GrandGulfNuclearStationemergency PhoneBookSectionE,Fireand MedicalSupport.3.3Management Standard#20,OperatingHardCard-ControlRoomActionsforMedicalEmergency' | |||
==4.0 ATTACHMENTS== | |||
4.1AttachmentI-Directions toClaiborne CountyHospital4.2AttachmentII-Directions toRiverRegionMedicalCenter5.0DEFINITIONS 5.1OSC-Operations SupportCenter5.2TSC-Technical SupportCenter5.3RPS-Radiation Protection Supervisor5.4REA-Radiation Emergency AreaJ:\ADM_SRVS\TECH_PUB\10\10S0119. | |||
DOC GRANDGULFNUCLEARSTATIONEMERGENCYPLANPROCEDURE ITitle:Personnel Injury6.0DETAILS6.1ReportingofInjuries IReVISion: | |||
021IPage:4MaintaincommunicationswiththeControlRoomuntilallreportedinformationisproperly acknowledged.6.1.1Anyindividualfindinganinjuredpersonwhorequiresmajormedicalassistanceistoimmediately NOTIFYtheControlRoombythe quickestavailablemeans.a.Thefollowing informationshouldbeprovidedtotheControlRoom:(1)Nameand locationoftheinjuredperson (2)Natureoftheemergency,ifknown.(3)IsMedical Help/Ambulance needed?(4)Nameofthecaller6.1.2TheControlRoomistoperformthefollowingactions.Ifavailableuse ManagementStandard#20-OperatingHardCardforMedicalEmergency:a.ImmediatelyNOTIFYthe Radiation Protection(RP)LaborSiteMedicalPersonneltodispatchFirstResponderstothescene.b.Ifrequired, ContactAmbulanceforresponsetoGrandGulfNuclearStation.Givethemthelocationoftheemergency.ProvideaCallBackNumberandsiteaddress;7003BaldHillRoad,PortGibson,MississippiTIME:_c.ContactSecurityIslandof Ambulanceresponseandauthorizeentry,as needed.d.HaveSecurity dispatchedtoscene,asnecessary. | |||
NameTime_e.SOUNDSiteFireAlarm;MAKEPAANNOUNCEMENT: | |||
"MEDICALEMERGENCY ATunnecessarypersonnelstayclearofthearea." | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IRevIsion: | |||
021f.REPEATnotificationevery5minutesuntiltheControlRoomhas confirmationthatthefirstaidteamhasbeenassembledatthescene. | |||
g.DispatchoperatortoscenewithFirstAidTraumaKitandAED.FirstAidTraumaKitandAEDlocationsarelistedon ManagementStandard#20. | |||
h.LContactIndustrialSafety. | |||
NameTime_ContactDutyManager. | |||
NameTime_j.ShiftManagerdeterminereportability,asneeded.6.1.3Ifduringdeclared emergency andemergencyresponsefacilitiesareoperational: | |||
a.NOTIFYtheOSCandprovidethe applicableinformationaboutthelocationoftheworkerandextentofinjuries,ifknown. | |||
b.NOTIFYtheTSCEmergencyPlantManager.6.2ImmediateActions6.2.1Uponreceiving notificationofamedicalemergency:theRPLabshould PERFORMthefollowing NOTE:TheFirstAidTeammaybenotifiedbyGaitronics,plantradioorpagerusingAlphaPagingontheGGNSHomePageunder Processes/Programs (pageFirstAidTeam)a.NotifytheControlRoomifnotalreadynotified. | |||
b.DISPATCHaFirstAidTeamtothesceneofthemedicalemergency.TheFirstAidpersonnelshouldbeequippedwiththefollowing: | |||
(1)FirstAidtraumakit(2)Portableradio(3)Radiological surveyinstruments andpersonnel protective equipment (Le.,respiratoryprotectiondevices,PCs)suitableforthehazardsatthelocationandthenatureoftheeventwhichcausedtheinjury(i.e.,fire,explosion). | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.2.1(continued) | |||
INo.:10-8-01-19EMERGENCYPLANPROCEDURE IRevIsion: | |||
021c.TheFirstAidTeamshouldestablishandmaintaincommunicationswiththeRPLab,ControlRoom,orOSCandprovideperiodicupdates.6.2.2FirstAidpersonnelaretoPERFORMthefollowingactionsatthesceneofthemedicalemergency:a.DETERMINEtheinjuredperson'sphysicalconditionandextentofinjuries.b.ADMINISTERfirstaidnecessarytosustainlifeandtostabilizetheinjured worker.c.MOVEtheinjuredpersontoasafelocationiflife-threateningradiologicalorphysicalhazardsarepresent. | |||
d.lEtheinjuryoccurredinaradiologicallypostedarea,THENperformacontaminationsurveyoftheinjuredworkerandREADtheworker's dosimetry.e.PROVIDEthefollowinginformationtotheRPLaborOSCRadChem Coordinator:RadiationProtection(OSCRadChemCoordinator)mustNotifytheControlRoomandprovidethefollowing information (1)Nameandlocationoftheinjuredperson. | |||
(2)Extentofinjuriesandtreatmentbeingadministered.(3)Personnel contamination surveyanddosimeterresultsfortheinjuredworker.(4)Theneedforanambulanceorotherassistance.f.PREPAREtheinjuredworkerfortransfertothehospital.g.RadiationProtectionpersonnelatthesceneofthemedicalemergencymustPERFORMradiologicalsurveysasnecessarytoprotectteammembersandsupportpersonnel. | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.3Ambulance Transport INo.:10-$-01-19 EMERGENCY PLANPROCEDURE IReVISion: | |||
021The-transportofinjuredpersonsisnormallyprovidedbytheregionalambulanceservice.Iftheregional ambulanceserviceisunavailable,theinjuredpersonshouldbetransportedincompanyownedorprivatevehicle. | |||
CAUTIONIfacontaminated injuredpersonistransported toanoffsitemedicalfacility, theNRCshallbenotifiedwithineighthours,inaccordance with01-5-06-5.6.3.1Ifambulance transportisnecessarythe ControlRoomshouldusethephonenumberslistedinReference3.2 torequestanambulance.a.Informthe ambulanceofthelocationoftheinjured,accesspointor anyotherinformationnecessary.6.3.2TheControlRoommustNOTIFYSecurityifanOnsiteorOffsite ambulance isrequiredtoentertheprotectedareaandmust SPECIFYthepatientpickuppoint.a.TheSecurity Coordinator mustENSUREthatOffsite ambulancecrewsareissueddosimetryattheentrancetotheProtectedArea.b.RadiationProtectionpersonnelatthesceneofthemedical emergency mustENSUREthatOffsiteambulancecrewmembersareproperlywearing theappropriate dosimetryandprotectiveclothingforentryinto radiologicallycontrolledareas.6.3.3TheShiftManagershouldNOTIFYtheEOFEmergency DirectorandINFORMhimofthetransportation ofaninjuredcontaminatedworkertothehospital.Thehospital.mustreceivethisinformationassoonaspossibleinordertomakethenecessary preparationsfortheemergency treatmentoftheworker.ThehospitalphonenumbersarelistedintheEmergencyTelephoneBook. | |||
J:\ADMSRVS\TECH PUB\10\10S0119.DOC | |||
-- | |||
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCYPLANPROCEDURE IPage:86.3.4TheRPSupervisor/Shift leadHP(OSCRadChern Coordinator) receiving theinitialinformation mustnotifythehospitalandprovidethefollowing information assoonaspossible. | |||
a.Nameofinjuredworker(s) b.Extentofinjuries c.Contaminationlevelsoninjuredworker(s),ifapplicabled.Expected arrivaltimeathospital,ifknown.6.3.5GGNSpersonnelshould PERFORMthefollowingenroutetothehospital:*AfriskerisnormallymaintainedintheOnsiteAmbulance*Surveysmaybelimitedorimpracticalduetotheextentofinjuriesreceivedbytheworker. | |||
a.PERFORMadetailedcontamination surveyoftheinjuredworkeriftheinjuryoccurredina RadiologicallyControlledArea.6.4OffsiteMedicalFacilities6.4.1TheRadiationProtection Supervisor/ShiftLeadHP(OSCRadChem Coordinator) isresponsible fordeterminingwhichmedicalfacilitytouse.Facilitiesavailableforuseinclude:a.ClaiborneCountyHospitalb.RiverRegionMedicalCenter 6.4.2AttachmentIandIIareusedto determine transportationroutestothemedical facilities. | |||
J:\AOM_SRVS\TECH_PUB\lO\lOSOl19:00C GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19EMERGENCYPLANPROCEDURE IPage:96.4.3Processforselectinghospitalfacilitiesduringnon-radiologicalemergenciesis:a.Non-contaminated,non-lifethreatening:RiverRegionMedicalCenter,orClaiborneCountyHospital.StreetClinicinVicksburgisrecommendedwhereapplicable.b.Non-contaminated,lifethreatening-transporttoClaiborneCounty Hospital.c.PlantSafetyandEMTpersonnelmayalsoauthorizehospitallocationsduringnon-radiologicalemergenciesusingtheguidelinesabove.6.4.4Contaminatedpersonnelwithminorormajorinjuriesshouldbetransportedtooneofthemedicalfacilitiesidentifiedin6.4.1.6.4.5Patientsmustbedeliveredtohospitalfacilitiesasfollows:a.AllinjuredworkerswhoarenotcontaminatedshouldbetransporteddirectlytothehospitalEmergencyRoom.b.Contaminatedpersonnelshouldbetransportedtothehospital Radiation Emergency Area.6.4.6Whenacontaminatedinjuredworkeristransportedtothehospital,GGNSpersonnelatthehospitalshouldprovidethefollowingsupport,ifavailable:a.PROVIDEthephysicianwithallavailableinformationconcerningtheaccidentandthecontaminationhazardspresent,uponrequest. | |||
b.ASSISTthehospitalstaff,ifpossible. | |||
.c,COORDINATEthecollectionanddisposalofcontaminatedwaste materials. | |||
d.COLLECTOffsiteambulancecrewdosimetryandPERFORMcontaminationsurveyofambulance. | |||
ARRANGEfordecontamination,if necessary.6.5HospitalPreparationtoReceivePatients6.5.1ThehospitalroomREA(RadiationEmergencyArea)isnormallysetupby hospitalp.ersonnelbeforethearrivalofthepatient. | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULF NUCLEARSTATIONEMERGENCY PLANPROCEDURE 10-S-01-19 Attachment IRevision:021Page1of1DIRECTIONS TOCLAIBORNE COUNTYHOSPITALG,:G1NSI{GrandGulfRoad DIRECTIONS:TakeHwy61Sto McCombAvenue(StateRoad547).GoEaston547andthehospitalisonyourleft.The entrancetotheRadiation EmergencyAreaisthroughthe Emergency RoomEntranceontheNorthendofthe hospitalJ:\ADM_SRVS\TECH_PUB\10\10S0119.DOC IIIIIII IIIPort:GibsonII IIIIHWY462HWY18III:Claiborne:CountyIHospitalo.llmAve GRANDGULF NUCLEARSTATION.EMERGENCY PLANPROCEDURE 10-S-01-19Revision:021 Attachment IIPage1of1DIRECTIONSTORIVERREGION MEDICALCENTERTakeUS61Northpast CulkinAve.Youwillseethe hospitalonyourright.The Emergency RoomentranceisontheSouthsideofthehospital. | |||
ThedoortotheDecontaminationRoomistothe rightoftheER.entrance. | |||
RiverRegion.A.-f---- | |||
MedicalCenter | |||
---.\DIRECTIONS: | |||
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC ATTACHMENT 9.1SHEET1OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartI.Description ofActivityBeingReviewed(eventoraction,orseriesofactionsthatmayresultinachangetotheemergencyplanoraffecttheimplementationoftheemergencyplan): | |||
Revision021:1.Changestoreporting emergencies andControlRoomactionstobeconsistent withManagement Standard#20.2.AddedMedicalFacility/Site Nursetosection2.3asanoptionforpersonnel requiring minorfirstaid,sincethisfacility/position ismannedduringoutages.3.AddedPlantOccupational HealthNursetosection6.4.3listofpersonnel whomayauthorize hospitalfacilities totransport patientsto.Editorial Changes:4.Addreference toManagement Standard#20-Operating Hard-Card, ControlRoomActionsforMedicalEmergency. | |||
(Reference CR-GGN-2016-2247 CA#2)5.ChangedthetitleRiverRegionHospitaltoMeritHealthRiverRegionduetoachangeinthefacilityname.PartII.ActivityPreviously Reviewed?IsthisactivityfullyboundedbyanNRCapproved10CFR50.90submittal orAlertandNotification SystemDesignReport?IfYES,identifyboundingsourcedocumentnumber/approval reference andensurethebasisforconcluding thesourcedocumentfullyboundstheproposedchangeisdocumented below:Justification: | |||
DBoundingdocumentattached(optional) | |||
DYES50.54(q)(3) | |||
Evaluation isNOTrequired. | |||
Enterjustification belowandcompletePartVI.t81NOContinuetonextpartPartIII.Applicability ofOtherRegulatory ChangeControlProcessesCheckifanyotherregulatorychangeprocessescontroltheproposed activity.(RefertoEN-L1-100)NOTE:Forexample,whenadesignchangeistheproposedactivity,consequentialactionsmayincludechangestootherdocumentswhichhaveadifferentchangecontrolprocessandareNOTtobeincludedinthis50.54(q)(3) | |||
Screening. | |||
APPLICABILITY CONCLUSIONIftherearenocontrollingchangeprocesses,continuethe50.54(q)(3)Screening. | |||
DOneormorecontrollingchangeprocessesareselected,however,someportionoftheactivityinvolvestheemergencyplanoraffectstheimplementationoftheemergencyplan;continuethe50.54(q)(3)Screeningforthatportionoftheactivity.Identifytheapplicablecontrollingchangeprocessesbelow. | |||
oOneormorecontrollingchangeprocessesareselectedandfullyboundsallaspectsoftheactivity. | |||
50.54(q)(3) | |||
Evaluation isNOTrequired.IdentifycontrollingchangeprocessesbelowandcompletePart VI.CONTROLLINGCHANGEPROCESSES EN-EP-305 REV3 ATTACHMENT 9.1SHEET2OF510CFR50.54(q), | |||
SCREENING Procedure/Document Number:10-5-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartIV.Editorial ChangeDYESt8JNO50.54(q)(3)ContinuetonextIsthisactivityaneditorialortypographicalchangesuchasformatting,paragraph Evaluation ispartnumbering,spelling,orpunctuationthatdoesnotchangeintent? | |||
NOTrequired. | |||
Justification: | |||
Changes#4&5arereferencechangesandareconsiderededitorial EnterjustificationandchangesaccordingtoEN-EP-305andEN-AD-101.NoischeckedattherightbecausecompleteParttheremainingchangesarenon-editorial. | |||
VI.PartV.Emergency PlanningElement/Function Screen(Associated10CFR50.47(b)planningstandardfunctionidentifiedinbrackets)Doesthisactivityaffectanyofthefollowing,includingprogramelementsfromNUREG-0654/FEMAREP-1SectionI/? | |||
1.Responsibility foremergency responseisassigned. | |||
[1]D2.Theresponseorganizationhasthestaffto respondandtoaugmentstaffonacontinuingbasis(24/7 Dstaffing) inaccordancewiththeemergencyplan.[1]3.Theprocessensuresthatonshiftemergency responseresponsibilities arestaffedandassigned.[2] | |||
D4.Theprocessfortimelyaugmentation ofonshiftstaffisestablished andmaintained. | |||
[2]D5.Arrangements forrequestingandusingoffsiteassistancehavebeenmade.[3] | |||
D6.StateandlocalstaffcanbeaccommodatedattheEOFin accordancewiththeemergencyplan.[3]DI7.Astandardschemeofemergency classificationandactionlevelsisinuse.[4] | |||
D8.Procedures fornotificationofStateandlocal governmental agenciesarecapableofalertingthemof Dthedeclaredemergency within15minutesafterdeclarationofanemergency andproviding follow-upnotifications. | |||
[5]9.Administrative andphysicalmeanshavebeenestablished foralertingandproviding promptDinstructionstothepublicwithintheplume exposurepathway.[5]10.ThepublicANSmeetsthedesignrequirements ofFEMA-REP-10,GuideforEvaluationofAlertand DNotification SystemsforNuclearPowerPlants,orcomplieswiththelicensee's FEMA-approved ANSdesignreportandsupporting FEMAapprovalletter.[5] | |||
11.Systemsareestablished forpromptcommunication amongprincipal emergency responseDorganizations. | |||
[6],12.Systemsareestablished forpromptcommunication toemergency responsepersonnel. | |||
[6]D13.Emergency preparedness information ismadeavailabletothepubliconaperiodicbasiswithinthe 0plumeexposurepathwayemergency planningzone(EPZ).[7] | |||
14.Coordinated dissemination ofpublicinformation duringemergencies isestablished. | |||
[7]*015.Adequatefacinties aremaintained tosupportemergency response. | |||
[8]D16.Adequateequipment ismaintained tosupportemergency response. | |||
[8]D17.Methods,systems,andequipment forassessment ofradioactive releasesareinuse.[9] | |||
D18.Arangeof publicPARsisavailable forimplementation duringemergencies. | |||
[10]D19.Evacuation timeestimatesforthepopulation locatedintheplume exposurepathwayEPZareDavailable tosupporttheformulationofPARsandhavebeen providedtoStateandlocal governmental authorities. | |||
[10]20.Arangeofprotective actionsisavailable forplantemergency workersduringemergencies, including Dthoseforhostileactionevents.[10] | |||
EN-EP-305 REV3 ATTACHMENT 9.1SHEET3OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel Injury21.Theresources forcontrolling radiological exposures foremergency workersareestablished. | |||
[11]D22.Arrangements aremadeformedicalservicesforcontaminated, injuredindividuals. | |||
[12]D23.Plansfor recoveryandreentryaredeveloped. | |||
[13]D24.Adrilland exerciseprogram(inclUding radiological, medical,healthphysicsandotherprogramDareas)isestablished. | |||
[14]25.Drills, exercises, andtrainingevolutions thatprovideperformance opportunities todevelop,Dmaintain, anddemonstratekeyskillsare assessedviaaformal critiqueprocessinordertoidentifyweaknesses. | |||
[14]26.Identified weaknesses arecorrected. | |||
[14]D27.Trainingisprovidedtoemergency responders. | |||
[15]D28.Responsibility foremergency plandevelopment andreviewisestablished. | |||
[16]D29.Plannersresponsible foremergency plandevelopment andmaintenance areproperlytrained.[16]DAPPLICABILITY CONCLUSION aIfnoPartVcriteriaarechecked,a50.54(q)(3)EvaluationisNOTrequired;documentthebasisforconclusionbelowandcompletePartVI. | |||
aIfanyPartVcriteriaarechecked,completePartVIandperforma50.54(q)(3)Evaluation.BASISFORCONCLUSION Changes#4&5areeditorialchangesanddonotrequireevaluation.1.ChangestoreportingemergenciesandControlRoomactionstobeconsistentwithManagementStandard#20.ThischangerevisestheinformationtheControlRoomshouldrequestfromacallerreportingamedical emergencyandaddsadditionalinformationtothestepstakenbytheControlRoomtorespondtotheemergency.Theplanningstandardsandprogramelementsrequirethatmedicalservicesbearrangedforcontaminated,injuredworkersbuttheydonotdescribetheactionstakenbythelicenseetorespondtomedicalemergencies.Thischangedoesnoteliminateanymedicalresponseequipmentorqualificationsanddoesnotaffectoffsite arrangementsformedicalsupportincludingtransportation.Thischangewillnotaffecttheplanningstandardsorprogramelementsin10CFR50.470(b)[12]anddoesnotneedanevaluation. | |||
EN-EP-305REV3 ATTACHMENT 9.1SHEET4OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryBASISFORCONCLUSION (continued) | |||
*AddedMedicalFacility/SiteNursetosection2.3asanoptionforpersonnelrequiringminorfirstaid,sincethis facility/positionismannedduringoutages. | |||
NormallyfirstaidcasesarehandledbyRPpersonnel.Duringoutages,whenwehaveanincreasein workforce, GrandGulfmaysetupasitemedicalfacility and/orstaffasitenursepositionto facilitatetheexpected increaseinfirstaid and/ormedicalemergencycases.Thisprocedurechangeallows personnelrequiringfirstaidtoreporttothesite medicalfacilityorsitenurse,ifstaffed,ratherthanlimitingthemtoreporttotheRP department. | |||
.*Theplanningstandardsandprogramelementsin 10CFR50.47(b)[10]requirearangeof protective actionsbeavailableforplantworkers,butdoesnotspecifythelocationorstaffingofsitefirstaid stationsormedicalfacilitiessothischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].*Thischangedoesnotreducethe numberoffirstaidqualified personnelanddoesnotreducetheshiftstaffingasrequiredin 10CFRS0.47(b)[2]orNUREG06s4tableB-1.thischangewillnotaffectthesitesabilitytomeetthe requirementsof1OCFRS0.47(b)[2].*Thischangedoesnotreducethe amountorlocationofmedical equipmentandsuppliesandwillnot affectthesitesabilitytomeetthe requirements of10CFR50.47(b)[8].*Thischangedoesnotaffectthe arrangementsinplaceformedicalservicesforcontaminatedand injuredindividualsandwillnotaffectthesitesabilitytomeetthe requirementsof10CFRS0.47(b)[12]. | |||
Thischangewillnotaffectanyoftheplanningstandardsorprogram elementsin1OCFR50.470(b)anddoes notrequireanevaluation. | |||
*AddedPlantOccupationalHealthNursetosectionlistofpersonnelwhomayauthorizewhich hospitalfacilitiestowhichpatientsaretransported. | |||
Section6.1.3of10-S-01-19 describestheprocessforselectinq hospitals duringnon-radiological emergenciesandliststhemedical facilitiespersonnelshouldbe transported tolife-threateningorlife-threateninginjuries.ThissectionstatesthatPlantSafetyandEMT personnel mayalsoauthorize hospitallocations.Thischangeaddstheplant OccupationalHealthNursetothatgroup.Thissection onlyappliestonon-contaminated individuals. | |||
*10CFR50.47(b)[12]requires licenseestoensurearrangements aremadefor.medical servicesforcontaminated, injuredindividuals. | |||
Thesearrangementswouldincludehospitals andotheroffsitemedicalfacilities. | |||
10-S-01-19liststhesefacilitiesinsection6.4.*1.Thechange beingmadeto10-S-01-19willnotaffectthislistortheprocessfor determiningwhichhospital totransport contaminated individualsto.Thischangewillnotaffectthesitesabilityto meettherequirements of10CFR50.47(b)[12].*Theplanningstandardsandprogram elementsin10CFR50.47(b)[10]requirearangeofprotective actionsbeavailableforplantworkers,butdoesnotspecifythepositionthatshoulddeterminewhat medicalfacilitiestouse.Thischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].Thechangesbeingmadeto 10-8-01-19willnotaffectanyof the10CFR50.47(b)planningstandardsorprogramelements.This changemaybemade withoutpriorNRCapprovalanddoesnotneeda 10CFR50.54q evaluation. | |||
EN-EP-305REV3 ATTACHMENT 9.1SHEET5OF510CFR50.54(q) | |||
SCREENING Procedure/Document Number:10-S-01-19 IRevision: | |||
21Equipment/Facility/Other: | |||
GrandGulfNuclearStationTitle:Personnel InjuryPartVI.Signatures:PreparerName(Print) | |||
Date:/:/--.7-RichardVanDen Akker<r:4-21-16i....._(Optional) | |||
ReviewerName(Print) | |||
ReviewerSignature Date:ReviewerName(Print) | |||
ReviewerSignature Date:TomSowdon Cf;4-22-2016NuclearEP ProjectManager.<< | |||
,//"e.-/''tttfJ-'tC4'l'..t:-- | |||
ApproverName(Print) | |||
ApproverSignature Date:--:rI£'P'PEPmanagerordesignee6')2./16//7'EN-EP-305REV3}} |
Revision as of 09:11, 30 June 2018
ML16123A346 | |
Person / Time | |
---|---|
Site: | Grand Gulf |
Issue date: | 05/02/2016 |
From: | Entergy Operations |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
10-S-01-19, Rev. 021 | |
Download: ML16123A346 (19) | |
Text
Volume10Section01PLANTOPERATIONS MANUALREFERENCE USEEMERGENCY PLANPROCEDURE PERSONNEL INJURYSAFETYRELATED10-8-01-19 Revision:
021Date:5-2-16Prepared:
Reviewed:Mag.ergencylaMingListofEffectivePages:
Pages1-9Attachments I-IIListofTCNsIncorporated:RevisionTCN oNone112-021NoneJ:\ADMLSRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEAR STATIONEMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19RPTSFORMRevision:
021Page:iREQUIREDREVIEWPERFORMED oPADo50.59Screen/Eva!.(Checkallthatapply)
(EN-L1-100)
(EN-L1-101)o72.48Screen/Eva!.
o50.54Eva!.TransmitapplicableReviewFormasa (EN-L1-112)
(EN-NS-210)separaterecordalongwith procedure tooPADNotRequired{EN-L1-100 or01-S-02-3)
DocumentControl.oProcessApplicability ExcludedoEditorial ChangeolSI/1STImplementation oTCNIncorporationorAutoRev.
oOtherProcess-Number:PADReviewer:
/(forPADNot Required)
Signature/Date Cross-Disci linereviewreuired?PrearerInitials>>>
(NoteaffectedDepartments Below)Department Cross-Discipline ReviewsNeededSignoff:(signed, electronic, telcon)Industrial Safety(.,..,."..*...c*.
\"""'--.::J
___Doesthisdirective containTechSpecTriggers?()YES(X)NOREQUIREMENTS CROSS-REFERENCE LISTRequirement Implemented byDirective Directive Paragraph NumberNameParagraph NumberThatImplements Requirement GGNSEmergency Plan6.7.3.51,52
&6.7.4.S56.3(Note)&6.4.110CFR5072.B.3.XII 6.3(Caution)
- Coveredby directiveasawholeorbyvarious paragraphsofthedirective.
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEARSTATION EMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19Revision:021Page:ii TheEquipment Database(EDB)Requeststatement isapplicableonlytoVolume06and07 maintenance directives.EDBChange Requestgeneratedandthebackup documentation available forsetpointand/orcalibrationdataonly DYesDN/AEDBCR#_CurrentRevision StatementRevision021:*Addreference toManagement Standard#20-OperatingHard-Card,ControlRoomActionsforMedicalEmergency.
(Reference CR-GGN-2016-2247CA#2)*Changestoreporting emergenciesandControlRoomactionstobe consistent withManagementStandard#20.
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.DOC I'Page:1EMERGENCY PLANPROCEDURE IReVISion:
021GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19
'---------------
TABLEOFCONTENTS' Page1.0PURPOSEANDDISCUSSION 22.0RESPONSIBILITIES
23.0REFERENCES
34.0ATTACHMENTS 35.0DEFINITIONS 36.0DETAILS46.1Reporting ofInjuries46.2Immediate Actions56.3Ambulance Transport 66.4OffsiteMedicalFacilities 86.5HospitalPreparation toReceivePatients9J:\ADM_SRVS\TECH_PGB\lO\lOSOl19.
DOC GRANDGULF NUCLEARSTATIONITitle:Personnel Injury1.0PURPOSEANDDISCUSSION 1.1PurposeINo.:1o-s-01-19 EMERGENCY PLANPROCEDURE1.1.1Toprovideguidanceonresponseto,reportingof,andtransferofinjured personnel underthefollowing conditions:a.Injuredperson requiring transporttoanoffsitemedicalcarefacilityb.Anyinjuriesdiscovered duringanemergency classification 1.2Discussion1.2.1Byagreement betweenEntergyOperations,Inc.andthe primaryandbackup.medicalcarefacilities, personnelattheGrand GulfNuclearStationsustaining injuriesfromionizingradiation orinjuriescomplicated byradiation exposureorradioactive contaminationaretobeprovidedcareandtreatment atthosefacilities.
Procedures andequipmentforthiscareand treatment aremaintained atthesefacilities.
Anindividual whoseclothing, skinand/orwoundsarecontaminated withradioactive materialmaypresentaradiation hazardtoattending personnelintheabsenceofadequateprocedures topreventthespreadofthecontaminant, orcontrolthe radiation exposureintheeventofradioactive shrapnelwound.Sinceradiation injuriesarenotimmediately life-threatening, primaryattention shouldalwaysbedirectedtotraumatic life-threatening injuries.
Aftersuchtreatment isrendered, thepatientshouldbedecontaminated.
2.0RESPONSIBILITIES2.1TheManager.Radiation Protection-IsresponsiblefortheimplementationoftheFirstAid ProgramatGGNS.2.2TheRadiation Protection Supervisor-Isresponsiblefortheadministration andmanagementoftheFirstAid Programincluding:2.2.1TheassignmentofaFirstAid qualified individualtoeachRadiation Protection shift.2.2.2Maintenanceoffirstaid suppliesandmedicalemergency responseequipment.
2.2.3Transportation ofinjuredpersonneltothehospitalandcontamination controlmeasuresasnecessary.
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.
DOC GRANDGULFNUCLEARSTATIONITitle:Personnel InjuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IReVISion:
0212.3AllGGNSpersonnel-Are toimmediately reportobservedseriousinjuriestotheControlRoom.Personnel withintheProtected Arearequiring minorfirstaidaretoreporttoRadiation Protection formedicaltreatment.
2.4TheOSCManager-Isresponsible fororganizing anddispatchingofFirstAid TeamsperEN-EP-611 whentheOSCisoperational.
2.5TheEOFPublicInformation Liaison-Isresponsible fornotifying theCompanySpokesperson regarding workerinjuriesduringadeclaredemergency.
3.0REFERENCES
3.1Corporate Procedure EN-IS-113, Reporting
&Investigating Occupational Injuries/Illnesses AndNearMisses3.2GrandGulfNuclearStationemergency PhoneBookSectionE,Fireand MedicalSupport.3.3Management Standard#20,OperatingHardCard-ControlRoomActionsforMedicalEmergency'
4.0 ATTACHMENTS
4.1AttachmentI-Directions toClaiborne CountyHospital4.2AttachmentII-Directions toRiverRegionMedicalCenter5.0DEFINITIONS 5.1OSC-Operations SupportCenter5.2TSC-Technical SupportCenter5.3RPS-Radiation Protection Supervisor5.4REA-Radiation Emergency AreaJ:\ADM_SRVS\TECH_PUB\10\10S0119.
DOC GRANDGULFNUCLEARSTATIONEMERGENCYPLANPROCEDURE ITitle:Personnel Injury6.0DETAILS6.1ReportingofInjuries IReVISion:
021IPage:4MaintaincommunicationswiththeControlRoomuntilallreportedinformationisproperly acknowledged.6.1.1Anyindividualfindinganinjuredpersonwhorequiresmajormedicalassistanceistoimmediately NOTIFYtheControlRoombythe quickestavailablemeans.a.Thefollowing informationshouldbeprovidedtotheControlRoom:(1)Nameand locationoftheinjuredperson (2)Natureoftheemergency,ifknown.(3)IsMedical Help/Ambulance needed?(4)Nameofthecaller6.1.2TheControlRoomistoperformthefollowingactions.Ifavailableuse ManagementStandard#20-OperatingHardCardforMedicalEmergency:a.ImmediatelyNOTIFYthe Radiation Protection(RP)LaborSiteMedicalPersonneltodispatchFirstResponderstothescene.b.Ifrequired, ContactAmbulanceforresponsetoGrandGulfNuclearStation.Givethemthelocationoftheemergency.ProvideaCallBackNumberandsiteaddress;7003BaldHillRoad,PortGibson,MississippiTIME:_c.ContactSecurityIslandof Ambulanceresponseandauthorizeentry,as needed.d.HaveSecurity dispatchedtoscene,asnecessary.
NameTime_e.SOUNDSiteFireAlarm;MAKEPAANNOUNCEMENT:
"MEDICALEMERGENCY ATunnecessarypersonnelstayclearofthearea."
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IRevIsion:
021f.REPEATnotificationevery5minutesuntiltheControlRoomhas confirmationthatthefirstaidteamhasbeenassembledatthescene.
g.DispatchoperatortoscenewithFirstAidTraumaKitandAED.FirstAidTraumaKitandAEDlocationsarelistedon ManagementStandard#20.
h.LContactIndustrialSafety.
NameTime_ContactDutyManager.
NameTime_j.ShiftManagerdeterminereportability,asneeded.6.1.3Ifduringdeclared emergency andemergencyresponsefacilitiesareoperational:
a.NOTIFYtheOSCandprovidethe applicableinformationaboutthelocationoftheworkerandextentofinjuries,ifknown.
b.NOTIFYtheTSCEmergencyPlantManager.6.2ImmediateActions6.2.1Uponreceiving notificationofamedicalemergency:theRPLabshould PERFORMthefollowing NOTE:TheFirstAidTeammaybenotifiedbyGaitronics,plantradioorpagerusingAlphaPagingontheGGNSHomePageunder Processes/Programs (pageFirstAidTeam)a.NotifytheControlRoomifnotalreadynotified.
b.DISPATCHaFirstAidTeamtothesceneofthemedicalemergency.TheFirstAidpersonnelshouldbeequippedwiththefollowing:
(1)FirstAidtraumakit(2)Portableradio(3)Radiological surveyinstruments andpersonnel protective equipment (Le.,respiratoryprotectiondevices,PCs)suitableforthehazardsatthelocationandthenatureoftheeventwhichcausedtheinjury(i.e.,fire,explosion).
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.2.1(continued)
INo.:10-8-01-19EMERGENCYPLANPROCEDURE IRevIsion:
021c.TheFirstAidTeamshouldestablishandmaintaincommunicationswiththeRPLab,ControlRoom,orOSCandprovideperiodicupdates.6.2.2FirstAidpersonnelaretoPERFORMthefollowingactionsatthesceneofthemedicalemergency:a.DETERMINEtheinjuredperson'sphysicalconditionandextentofinjuries.b.ADMINISTERfirstaidnecessarytosustainlifeandtostabilizetheinjured worker.c.MOVEtheinjuredpersontoasafelocationiflife-threateningradiologicalorphysicalhazardsarepresent.
d.lEtheinjuryoccurredinaradiologicallypostedarea,THENperformacontaminationsurveyoftheinjuredworkerandREADtheworker's dosimetry.e.PROVIDEthefollowinginformationtotheRPLaborOSCRadChem Coordinator:RadiationProtection(OSCRadChemCoordinator)mustNotifytheControlRoomandprovidethefollowing information (1)Nameandlocationoftheinjuredperson.
(2)Extentofinjuriesandtreatmentbeingadministered.(3)Personnel contamination surveyanddosimeterresultsfortheinjuredworker.(4)Theneedforanambulanceorotherassistance.f.PREPAREtheinjuredworkerfortransfertothehospital.g.RadiationProtectionpersonnelatthesceneofthemedicalemergencymustPERFORMradiologicalsurveysasnecessarytoprotectteammembersandsupportpersonnel.
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.3Ambulance Transport INo.:10-$-01-19 EMERGENCY PLANPROCEDURE IReVISion:
021The-transportofinjuredpersonsisnormallyprovidedbytheregionalambulanceservice.Iftheregional ambulanceserviceisunavailable,theinjuredpersonshouldbetransportedincompanyownedorprivatevehicle.
CAUTIONIfacontaminated injuredpersonistransported toanoffsitemedicalfacility, theNRCshallbenotifiedwithineighthours,inaccordance with01-5-06-5.6.3.1Ifambulance transportisnecessarythe ControlRoomshouldusethephonenumberslistedinReference3.2 torequestanambulance.a.Informthe ambulanceofthelocationoftheinjured,accesspointor anyotherinformationnecessary.6.3.2TheControlRoommustNOTIFYSecurityifanOnsiteorOffsite ambulance isrequiredtoentertheprotectedareaandmust SPECIFYthepatientpickuppoint.a.TheSecurity Coordinator mustENSUREthatOffsite ambulancecrewsareissueddosimetryattheentrancetotheProtectedArea.b.RadiationProtectionpersonnelatthesceneofthemedical emergency mustENSUREthatOffsiteambulancecrewmembersareproperlywearing theappropriate dosimetryandprotectiveclothingforentryinto radiologicallycontrolledareas.6.3.3TheShiftManagershouldNOTIFYtheEOFEmergency DirectorandINFORMhimofthetransportation ofaninjuredcontaminatedworkertothehospital.Thehospital.mustreceivethisinformationassoonaspossibleinordertomakethenecessary preparationsfortheemergency treatmentoftheworker.ThehospitalphonenumbersarelistedintheEmergencyTelephoneBook.
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCYPLANPROCEDURE IPage:86.3.4TheRPSupervisor/Shift leadHP(OSCRadChern Coordinator) receiving theinitialinformation mustnotifythehospitalandprovidethefollowing information assoonaspossible.
a.Nameofinjuredworker(s) b.Extentofinjuries c.Contaminationlevelsoninjuredworker(s),ifapplicabled.Expected arrivaltimeathospital,ifknown.6.3.5GGNSpersonnelshould PERFORMthefollowingenroutetothehospital:*AfriskerisnormallymaintainedintheOnsiteAmbulance*Surveysmaybelimitedorimpracticalduetotheextentofinjuriesreceivedbytheworker.
a.PERFORMadetailedcontamination surveyoftheinjuredworkeriftheinjuryoccurredina RadiologicallyControlledArea.6.4OffsiteMedicalFacilities6.4.1TheRadiationProtection Supervisor/ShiftLeadHP(OSCRadChem Coordinator) isresponsible fordeterminingwhichmedicalfacilitytouse.Facilitiesavailableforuseinclude:a.ClaiborneCountyHospitalb.RiverRegionMedicalCenter 6.4.2AttachmentIandIIareusedto determine transportationroutestothemedical facilities.
J:\AOM_SRVS\TECH_PUB\lO\lOSOl19:00C GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19EMERGENCYPLANPROCEDURE IPage:96.4.3Processforselectinghospitalfacilitiesduringnon-radiologicalemergenciesis:a.Non-contaminated,non-lifethreatening:RiverRegionMedicalCenter,orClaiborneCountyHospital.StreetClinicinVicksburgisrecommendedwhereapplicable.b.Non-contaminated,lifethreatening-transporttoClaiborneCounty Hospital.c.PlantSafetyandEMTpersonnelmayalsoauthorizehospitallocationsduringnon-radiologicalemergenciesusingtheguidelinesabove.6.4.4Contaminatedpersonnelwithminorormajorinjuriesshouldbetransportedtooneofthemedicalfacilitiesidentifiedin6.4.1.6.4.5Patientsmustbedeliveredtohospitalfacilitiesasfollows:a.AllinjuredworkerswhoarenotcontaminatedshouldbetransporteddirectlytothehospitalEmergencyRoom.b.Contaminatedpersonnelshouldbetransportedtothehospital Radiation Emergency Area.6.4.6Whenacontaminatedinjuredworkeristransportedtothehospital,GGNSpersonnelatthehospitalshouldprovidethefollowingsupport,ifavailable:a.PROVIDEthephysicianwithallavailableinformationconcerningtheaccidentandthecontaminationhazardspresent,uponrequest.
b.ASSISTthehospitalstaff,ifpossible.
.c,COORDINATEthecollectionanddisposalofcontaminatedwaste materials.
d.COLLECTOffsiteambulancecrewdosimetryandPERFORMcontaminationsurveyofambulance.
ARRANGEfordecontamination,if necessary.6.5HospitalPreparationtoReceivePatients6.5.1ThehospitalroomREA(RadiationEmergencyArea)isnormallysetupby hospitalp.ersonnelbeforethearrivalofthepatient.
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULF NUCLEARSTATIONEMERGENCY PLANPROCEDURE 10-S-01-19 Attachment IRevision:021Page1of1DIRECTIONS TOCLAIBORNE COUNTYHOSPITALG,:G1NSI{GrandGulfRoad DIRECTIONS:TakeHwy61Sto McCombAvenue(StateRoad547).GoEaston547andthehospitalisonyourleft.The entrancetotheRadiation EmergencyAreaisthroughthe Emergency RoomEntranceontheNorthendofthe hospitalJ:\ADM_SRVS\TECH_PUB\10\10S0119.DOC IIIIIII IIIPort:GibsonII IIIIHWY462HWY18III:Claiborne:CountyIHospitalo.llmAve GRANDGULF NUCLEARSTATION.EMERGENCY PLANPROCEDURE 10-S-01-19Revision:021 Attachment IIPage1of1DIRECTIONSTORIVERREGION MEDICALCENTERTakeUS61Northpast CulkinAve.Youwillseethe hospitalonyourright.The Emergency RoomentranceisontheSouthsideofthehospital.
ThedoortotheDecontaminationRoomistothe rightoftheER.entrance.
RiverRegion.A.-f----
MedicalCenter
---.\DIRECTIONS:
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC ATTACHMENT 9.1SHEET1OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartI.Description ofActivityBeingReviewed(eventoraction,orseriesofactionsthatmayresultinachangetotheemergencyplanoraffecttheimplementationoftheemergencyplan):
Revision021:1.Changestoreporting emergencies andControlRoomactionstobeconsistent withManagement Standard#20.2.AddedMedicalFacility/Site Nursetosection2.3asanoptionforpersonnel requiring minorfirstaid,sincethisfacility/position ismannedduringoutages.3.AddedPlantOccupational HealthNursetosection6.4.3listofpersonnel whomayauthorize hospitalfacilities totransport patientsto.Editorial Changes:4.Addreference toManagement Standard#20-Operating Hard-Card, ControlRoomActionsforMedicalEmergency.
(Reference CR-GGN-2016-2247 CA#2)5.ChangedthetitleRiverRegionHospitaltoMeritHealthRiverRegionduetoachangeinthefacilityname.PartII.ActivityPreviously Reviewed?IsthisactivityfullyboundedbyanNRCapproved10CFR50.90submittal orAlertandNotification SystemDesignReport?IfYES,identifyboundingsourcedocumentnumber/approval reference andensurethebasisforconcluding thesourcedocumentfullyboundstheproposedchangeisdocumented below:Justification:
DBoundingdocumentattached(optional)
DYES50.54(q)(3)
Evaluation isNOTrequired.
Enterjustification belowandcompletePartVI.t81NOContinuetonextpartPartIII.Applicability ofOtherRegulatory ChangeControlProcessesCheckifanyotherregulatorychangeprocessescontroltheproposed activity.(RefertoEN-L1-100)NOTE:Forexample,whenadesignchangeistheproposedactivity,consequentialactionsmayincludechangestootherdocumentswhichhaveadifferentchangecontrolprocessandareNOTtobeincludedinthis50.54(q)(3)
Screening.
APPLICABILITY CONCLUSIONIftherearenocontrollingchangeprocesses,continuethe50.54(q)(3)Screening.
DOneormorecontrollingchangeprocessesareselected,however,someportionoftheactivityinvolvestheemergencyplanoraffectstheimplementationoftheemergencyplan;continuethe50.54(q)(3)Screeningforthatportionoftheactivity.Identifytheapplicablecontrollingchangeprocessesbelow.
oOneormorecontrollingchangeprocessesareselectedandfullyboundsallaspectsoftheactivity.
50.54(q)(3)
Evaluation isNOTrequired.IdentifycontrollingchangeprocessesbelowandcompletePart VI.CONTROLLINGCHANGEPROCESSES EN-EP-305 REV3 ATTACHMENT 9.1SHEET2OF510CFR50.54(q),
SCREENING Procedure/Document Number:10-5-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartIV.Editorial ChangeDYESt8JNO50.54(q)(3)ContinuetonextIsthisactivityaneditorialortypographicalchangesuchasformatting,paragraph Evaluation ispartnumbering,spelling,orpunctuationthatdoesnotchangeintent?
NOTrequired.
Justification:
Changes#4&5arereferencechangesandareconsiderededitorial EnterjustificationandchangesaccordingtoEN-EP-305andEN-AD-101.NoischeckedattherightbecausecompleteParttheremainingchangesarenon-editorial.
VI.PartV.Emergency PlanningElement/Function Screen(Associated10CFR50.47(b)planningstandardfunctionidentifiedinbrackets)Doesthisactivityaffectanyofthefollowing,includingprogramelementsfromNUREG-0654/FEMAREP-1SectionI/?
1.Responsibility foremergency responseisassigned.
[1]D2.Theresponseorganizationhasthestaffto respondandtoaugmentstaffonacontinuingbasis(24/7 Dstaffing) inaccordancewiththeemergencyplan.[1]3.Theprocessensuresthatonshiftemergency responseresponsibilities arestaffedandassigned.[2]
D4.Theprocessfortimelyaugmentation ofonshiftstaffisestablished andmaintained.
[2]D5.Arrangements forrequestingandusingoffsiteassistancehavebeenmade.[3]
D6.StateandlocalstaffcanbeaccommodatedattheEOFin accordancewiththeemergencyplan.[3]DI7.Astandardschemeofemergency classificationandactionlevelsisinuse.[4]
D8.Procedures fornotificationofStateandlocal governmental agenciesarecapableofalertingthemof Dthedeclaredemergency within15minutesafterdeclarationofanemergency andproviding follow-upnotifications.
[5]9.Administrative andphysicalmeanshavebeenestablished foralertingandproviding promptDinstructionstothepublicwithintheplume exposurepathway.[5]10.ThepublicANSmeetsthedesignrequirements ofFEMA-REP-10,GuideforEvaluationofAlertand DNotification SystemsforNuclearPowerPlants,orcomplieswiththelicensee's FEMA-approved ANSdesignreportandsupporting FEMAapprovalletter.[5]
11.Systemsareestablished forpromptcommunication amongprincipal emergency responseDorganizations.
[6],12.Systemsareestablished forpromptcommunication toemergency responsepersonnel.
[6]D13.Emergency preparedness information ismadeavailabletothepubliconaperiodicbasiswithinthe 0plumeexposurepathwayemergency planningzone(EPZ).[7]
14.Coordinated dissemination ofpublicinformation duringemergencies isestablished.
[7]*015.Adequatefacinties aremaintained tosupportemergency response.
[8]D16.Adequateequipment ismaintained tosupportemergency response.
[8]D17.Methods,systems,andequipment forassessment ofradioactive releasesareinuse.[9]
D18.Arangeof publicPARsisavailable forimplementation duringemergencies.
[10]D19.Evacuation timeestimatesforthepopulation locatedintheplume exposurepathwayEPZareDavailable tosupporttheformulationofPARsandhavebeen providedtoStateandlocal governmental authorities.
[10]20.Arangeofprotective actionsisavailable forplantemergency workersduringemergencies, including Dthoseforhostileactionevents.[10]
EN-EP-305 REV3 ATTACHMENT 9.1SHEET3OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel Injury21.Theresources forcontrolling radiological exposures foremergency workersareestablished.
[11]D22.Arrangements aremadeformedicalservicesforcontaminated, injuredindividuals.
[12]D23.Plansfor recoveryandreentryaredeveloped.
[13]D24.Adrilland exerciseprogram(inclUding radiological, medical,healthphysicsandotherprogramDareas)isestablished.
[14]25.Drills, exercises, andtrainingevolutions thatprovideperformance opportunities todevelop,Dmaintain, anddemonstratekeyskillsare assessedviaaformal critiqueprocessinordertoidentifyweaknesses.
[14]26.Identified weaknesses arecorrected.
[14]D27.Trainingisprovidedtoemergency responders.
[15]D28.Responsibility foremergency plandevelopment andreviewisestablished.
[16]D29.Plannersresponsible foremergency plandevelopment andmaintenance areproperlytrained.[16]DAPPLICABILITY CONCLUSION aIfnoPartVcriteriaarechecked,a50.54(q)(3)EvaluationisNOTrequired;documentthebasisforconclusionbelowandcompletePartVI.
aIfanyPartVcriteriaarechecked,completePartVIandperforma50.54(q)(3)Evaluation.BASISFORCONCLUSION Changes#4&5areeditorialchangesanddonotrequireevaluation.1.ChangestoreportingemergenciesandControlRoomactionstobeconsistentwithManagementStandard#20.ThischangerevisestheinformationtheControlRoomshouldrequestfromacallerreportingamedical emergencyandaddsadditionalinformationtothestepstakenbytheControlRoomtorespondtotheemergency.Theplanningstandardsandprogramelementsrequirethatmedicalservicesbearrangedforcontaminated,injuredworkersbuttheydonotdescribetheactionstakenbythelicenseetorespondtomedicalemergencies.Thischangedoesnoteliminateanymedicalresponseequipmentorqualificationsanddoesnotaffectoffsite arrangementsformedicalsupportincludingtransportation.Thischangewillnotaffecttheplanningstandardsorprogramelementsin10CFR50.470(b)[12]anddoesnotneedanevaluation.
EN-EP-305REV3 ATTACHMENT 9.1SHEET4OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryBASISFORCONCLUSION (continued)
- AddedMedicalFacility/SiteNursetosection2.3asanoptionforpersonnelrequiringminorfirstaid,sincethis facility/positionismannedduringoutages.
NormallyfirstaidcasesarehandledbyRPpersonnel.Duringoutages,whenwehaveanincreasein workforce, GrandGulfmaysetupasitemedicalfacility and/orstaffasitenursepositionto facilitatetheexpected increaseinfirstaid and/ormedicalemergencycases.Thisprocedurechangeallows personnelrequiringfirstaidtoreporttothesite medicalfacilityorsitenurse,ifstaffed,ratherthanlimitingthemtoreporttotheRP department.
.*Theplanningstandardsandprogramelementsin 10CFR50.47(b)[10]requirearangeof protective actionsbeavailableforplantworkers,butdoesnotspecifythelocationorstaffingofsitefirstaid stationsormedicalfacilitiessothischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].*Thischangedoesnotreducethe numberoffirstaidqualified personnelanddoesnotreducetheshiftstaffingasrequiredin 10CFRS0.47(b)[2]orNUREG06s4tableB-1.thischangewillnotaffectthesitesabilitytomeetthe requirementsof1OCFRS0.47(b)[2].*Thischangedoesnotreducethe amountorlocationofmedical equipmentandsuppliesandwillnot affectthesitesabilitytomeetthe requirements of10CFR50.47(b)[8].*Thischangedoesnotaffectthe arrangementsinplaceformedicalservicesforcontaminatedand injuredindividualsandwillnotaffectthesitesabilitytomeetthe requirementsof10CFRS0.47(b)[12].
Thischangewillnotaffectanyoftheplanningstandardsorprogram elementsin1OCFR50.470(b)anddoes notrequireanevaluation.
- AddedPlantOccupationalHealthNursetosectionlistofpersonnelwhomayauthorizewhich hospitalfacilitiestowhichpatientsaretransported.
Section6.1.3of10-S-01-19 describestheprocessforselectinq hospitals duringnon-radiological emergenciesandliststhemedical facilitiespersonnelshouldbe transported tolife-threateningorlife-threateninginjuries.ThissectionstatesthatPlantSafetyandEMT personnel mayalsoauthorize hospitallocations.Thischangeaddstheplant OccupationalHealthNursetothatgroup.Thissection onlyappliestonon-contaminated individuals.
- 10CFR50.47(b)[12]requires licenseestoensurearrangements aremadefor.medical servicesforcontaminated, injuredindividuals.
Thesearrangementswouldincludehospitals andotheroffsitemedicalfacilities.
10-S-01-19liststhesefacilitiesinsection6.4.*1.Thechange beingmadeto10-S-01-19willnotaffectthislistortheprocessfor determiningwhichhospital totransport contaminated individualsto.Thischangewillnotaffectthesitesabilityto meettherequirements of10CFR50.47(b)[12].*Theplanningstandardsandprogram elementsin10CFR50.47(b)[10]requirearangeofprotective actionsbeavailableforplantworkers,butdoesnotspecifythepositionthatshoulddeterminewhat medicalfacilitiestouse.Thischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].Thechangesbeingmadeto 10-8-01-19willnotaffectanyof the10CFR50.47(b)planningstandardsorprogramelements.This changemaybemade withoutpriorNRCapprovalanddoesnotneeda 10CFR50.54q evaluation.
EN-EP-305REV3 ATTACHMENT 9.1SHEET5OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartVI.Signatures:PreparerName(Print)
Date:/:/--.7-RichardVanDen Akker<r:4-21-16i....._(Optional)
ReviewerName(Print)
ReviewerSignature Date:ReviewerName(Print)
ReviewerSignature Date:TomSowdon Cf;4-22-2016NuclearEP ProjectManager.<<
,//"e.-/tttfJ-'tC4'l'..t:--
ApproverName(Print)
ApproverSignature Date:--:rI£'P'PEPmanagerordesignee6')2./16//7'EN-EP-305REV3 Volume10Section01PLANTOPERATIONS MANUALREFERENCE USEEMERGENCY PLANPROCEDURE PERSONNEL INJURYSAFETYRELATED10-8-01-19 Revision:
021Date:5-2-16Prepared:
Reviewed:Mag.ergencylaMingListofEffectivePages:
Pages1-9Attachments I-IIListofTCNsIncorporated:RevisionTCN oNone112-021NoneJ:\ADMLSRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEAR STATIONEMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19RPTSFORMRevision:
021Page:iREQUIREDREVIEWPERFORMED oPADo50.59Screen/Eva!.(Checkallthatapply)
(EN-L1-100)
(EN-L1-101)o72.48Screen/Eva!.
o50.54Eva!.TransmitapplicableReviewFormasa (EN-L1-112)
(EN-NS-210)separaterecordalongwith procedure tooPADNotRequired{EN-L1-100 or01-S-02-3)
DocumentControl.oProcessApplicability ExcludedoEditorial ChangeolSI/1STImplementation oTCNIncorporationorAutoRev.
oOtherProcess-Number:PADReviewer:
/(forPADNot Required)
Signature/Date Cross-Disci linereviewreuired?PrearerInitials>>>
(NoteaffectedDepartments Below)Department Cross-Discipline ReviewsNeededSignoff:(signed, electronic, telcon)Industrial Safety(.,..,."..*...c*.
\"""'--.::J
___Doesthisdirective containTechSpecTriggers?()YES(X)NOREQUIREMENTS CROSS-REFERENCE LISTRequirement Implemented byDirective Directive Paragraph NumberNameParagraph NumberThatImplements Requirement GGNSEmergency Plan6.7.3.51,52
&6.7.4.S56.3(Note)&6.4.110CFR5072.B.3.XII 6.3(Caution)
- Coveredby directiveasawholeorbyvarious paragraphsofthedirective.
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULFNUCLEARSTATION EMERGENCY PLANPROCEDURETitle:PersonnelInjury No.:10-S-01-19Revision:021Page:ii TheEquipment Database(EDB)Requeststatement isapplicableonlytoVolume06and07 maintenance directives.EDBChange Requestgeneratedandthebackup documentation available forsetpointand/orcalibrationdataonly DYesDN/AEDBCR#_CurrentRevision StatementRevision021:*Addreference toManagement Standard#20-OperatingHard-Card,ControlRoomActionsforMedicalEmergency.
(Reference CR-GGN-2016-2247CA#2)*Changestoreporting emergenciesandControlRoomactionstobe consistent withManagementStandard#20.
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.DOC I'Page:1EMERGENCY PLANPROCEDURE IReVISion:
021GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19
'---------------
TABLEOFCONTENTS' Page1.0PURPOSEANDDISCUSSION 22.0RESPONSIBILITIES
23.0REFERENCES
34.0ATTACHMENTS 35.0DEFINITIONS 36.0DETAILS46.1Reporting ofInjuries46.2Immediate Actions56.3Ambulance Transport 66.4OffsiteMedicalFacilities 86.5HospitalPreparation toReceivePatients9J:\ADM_SRVS\TECH_PGB\lO\lOSOl19.
DOC GRANDGULF NUCLEARSTATIONITitle:Personnel Injury1.0PURPOSEANDDISCUSSION 1.1PurposeINo.:1o-s-01-19 EMERGENCY PLANPROCEDURE1.1.1Toprovideguidanceonresponseto,reportingof,andtransferofinjured personnel underthefollowing conditions:a.Injuredperson requiring transporttoanoffsitemedicalcarefacilityb.Anyinjuriesdiscovered duringanemergency classification 1.2Discussion1.2.1Byagreement betweenEntergyOperations,Inc.andthe primaryandbackup.medicalcarefacilities, personnelattheGrand GulfNuclearStationsustaining injuriesfromionizingradiation orinjuriescomplicated byradiation exposureorradioactive contaminationaretobeprovidedcareandtreatment atthosefacilities.
Procedures andequipmentforthiscareand treatment aremaintained atthesefacilities.
Anindividual whoseclothing, skinand/orwoundsarecontaminated withradioactive materialmaypresentaradiation hazardtoattending personnelintheabsenceofadequateprocedures topreventthespreadofthecontaminant, orcontrolthe radiation exposureintheeventofradioactive shrapnelwound.Sinceradiation injuriesarenotimmediately life-threatening, primaryattention shouldalwaysbedirectedtotraumatic life-threatening injuries.
Aftersuchtreatment isrendered, thepatientshouldbedecontaminated.
2.0RESPONSIBILITIES2.1TheManager.Radiation Protection-IsresponsiblefortheimplementationoftheFirstAid ProgramatGGNS.2.2TheRadiation Protection Supervisor-Isresponsiblefortheadministration andmanagementoftheFirstAid Programincluding:2.2.1TheassignmentofaFirstAid qualified individualtoeachRadiation Protection shift.2.2.2Maintenanceoffirstaid suppliesandmedicalemergency responseequipment.
2.2.3Transportation ofinjuredpersonneltothehospitalandcontamination controlmeasuresasnecessary.
J:\ADM_SRVS\TECH_PUB\lO\lOSOl19.
DOC GRANDGULFNUCLEARSTATIONITitle:Personnel InjuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IReVISion:
0212.3AllGGNSpersonnel-Are toimmediately reportobservedseriousinjuriestotheControlRoom.Personnel withintheProtected Arearequiring minorfirstaidaretoreporttoRadiation Protection formedicaltreatment.
2.4TheOSCManager-Isresponsible fororganizing anddispatchingofFirstAid TeamsperEN-EP-611 whentheOSCisoperational.
2.5TheEOFPublicInformation Liaison-Isresponsible fornotifying theCompanySpokesperson regarding workerinjuriesduringadeclaredemergency.
3.0REFERENCES
3.1Corporate Procedure EN-IS-113, Reporting
&Investigating Occupational Injuries/Illnesses AndNearMisses3.2GrandGulfNuclearStationemergency PhoneBookSectionE,Fireand MedicalSupport.3.3Management Standard#20,OperatingHardCard-ControlRoomActionsforMedicalEmergency'
4.0 ATTACHMENTS
4.1AttachmentI-Directions toClaiborne CountyHospital4.2AttachmentII-Directions toRiverRegionMedicalCenter5.0DEFINITIONS 5.1OSC-Operations SupportCenter5.2TSC-Technical SupportCenter5.3RPS-Radiation Protection Supervisor5.4REA-Radiation Emergency AreaJ:\ADM_SRVS\TECH_PUB\10\10S0119.
DOC GRANDGULFNUCLEARSTATIONEMERGENCYPLANPROCEDURE ITitle:Personnel Injury6.0DETAILS6.1ReportingofInjuries IReVISion:
021IPage:4MaintaincommunicationswiththeControlRoomuntilallreportedinformationisproperly acknowledged.6.1.1Anyindividualfindinganinjuredpersonwhorequiresmajormedicalassistanceistoimmediately NOTIFYtheControlRoombythe quickestavailablemeans.a.Thefollowing informationshouldbeprovidedtotheControlRoom:(1)Nameand locationoftheinjuredperson (2)Natureoftheemergency,ifknown.(3)IsMedical Help/Ambulance needed?(4)Nameofthecaller6.1.2TheControlRoomistoperformthefollowingactions.Ifavailableuse ManagementStandard#20-OperatingHardCardforMedicalEmergency:a.ImmediatelyNOTIFYthe Radiation Protection(RP)LaborSiteMedicalPersonneltodispatchFirstResponderstothescene.b.Ifrequired, ContactAmbulanceforresponsetoGrandGulfNuclearStation.Givethemthelocationoftheemergency.ProvideaCallBackNumberandsiteaddress;7003BaldHillRoad,PortGibson,MississippiTIME:_c.ContactSecurityIslandof Ambulanceresponseandauthorizeentry,as needed.d.HaveSecurity dispatchedtoscene,asnecessary.
NameTime_e.SOUNDSiteFireAlarm;MAKEPAANNOUNCEMENT:
"MEDICALEMERGENCY ATunnecessarypersonnelstayclearofthearea."
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCY PLANPROCEDURE IRevIsion:
021f.REPEATnotificationevery5minutesuntiltheControlRoomhas confirmationthatthefirstaidteamhasbeenassembledatthescene.
g.DispatchoperatortoscenewithFirstAidTraumaKitandAED.FirstAidTraumaKitandAEDlocationsarelistedon ManagementStandard#20.
h.LContactIndustrialSafety.
NameTime_ContactDutyManager.
NameTime_j.ShiftManagerdeterminereportability,asneeded.6.1.3Ifduringdeclared emergency andemergencyresponsefacilitiesareoperational:
a.NOTIFYtheOSCandprovidethe applicableinformationaboutthelocationoftheworkerandextentofinjuries,ifknown.
b.NOTIFYtheTSCEmergencyPlantManager.6.2ImmediateActions6.2.1Uponreceiving notificationofamedicalemergency:theRPLabshould PERFORMthefollowing NOTE:TheFirstAidTeammaybenotifiedbyGaitronics,plantradioorpagerusingAlphaPagingontheGGNSHomePageunder Processes/Programs (pageFirstAidTeam)a.NotifytheControlRoomifnotalreadynotified.
b.DISPATCHaFirstAidTeamtothesceneofthemedicalemergency.TheFirstAidpersonnelshouldbeequippedwiththefollowing:
(1)FirstAidtraumakit(2)Portableradio(3)Radiological surveyinstruments andpersonnel protective equipment (Le.,respiratoryprotectiondevices,PCs)suitableforthehazardsatthelocationandthenatureoftheeventwhichcausedtheinjury(i.e.,fire,explosion).
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.2.1(continued)
INo.:10-8-01-19EMERGENCYPLANPROCEDURE IRevIsion:
021c.TheFirstAidTeamshouldestablishandmaintaincommunicationswiththeRPLab,ControlRoom,orOSCandprovideperiodicupdates.6.2.2FirstAidpersonnelaretoPERFORMthefollowingactionsatthesceneofthemedicalemergency:a.DETERMINEtheinjuredperson'sphysicalconditionandextentofinjuries.b.ADMINISTERfirstaidnecessarytosustainlifeandtostabilizetheinjured worker.c.MOVEtheinjuredpersontoasafelocationiflife-threateningradiologicalorphysicalhazardsarepresent.
d.lEtheinjuryoccurredinaradiologicallypostedarea,THENperformacontaminationsurveyoftheinjuredworkerandREADtheworker's dosimetry.e.PROVIDEthefollowinginformationtotheRPLaborOSCRadChem Coordinator:RadiationProtection(OSCRadChemCoordinator)mustNotifytheControlRoomandprovidethefollowing information (1)Nameandlocationoftheinjuredperson.
(2)Extentofinjuriesandtreatmentbeingadministered.(3)Personnel contamination surveyanddosimeterresultsfortheinjuredworker.(4)Theneedforanambulanceorotherassistance.f.PREPAREtheinjuredworkerfortransfertothehospital.g.RadiationProtectionpersonnelatthesceneofthemedicalemergencymustPERFORMradiologicalsurveysasnecessarytoprotectteammembersandsupportpersonnel.
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJury6.3Ambulance Transport INo.:10-$-01-19 EMERGENCY PLANPROCEDURE IReVISion:
021The-transportofinjuredpersonsisnormallyprovidedbytheregionalambulanceservice.Iftheregional ambulanceserviceisunavailable,theinjuredpersonshouldbetransportedincompanyownedorprivatevehicle.
CAUTIONIfacontaminated injuredpersonistransported toanoffsitemedicalfacility, theNRCshallbenotifiedwithineighthours,inaccordance with01-5-06-5.6.3.1Ifambulance transportisnecessarythe ControlRoomshouldusethephonenumberslistedinReference3.2 torequestanambulance.a.Informthe ambulanceofthelocationoftheinjured,accesspointor anyotherinformationnecessary.6.3.2TheControlRoommustNOTIFYSecurityifanOnsiteorOffsite ambulance isrequiredtoentertheprotectedareaandmust SPECIFYthepatientpickuppoint.a.TheSecurity Coordinator mustENSUREthatOffsite ambulancecrewsareissueddosimetryattheentrancetotheProtectedArea.b.RadiationProtectionpersonnelatthesceneofthemedical emergency mustENSUREthatOffsiteambulancecrewmembersareproperlywearing theappropriate dosimetryandprotectiveclothingforentryinto radiologicallycontrolledareas.6.3.3TheShiftManagershouldNOTIFYtheEOFEmergency DirectorandINFORMhimofthetransportation ofaninjuredcontaminatedworkertothehospital.Thehospital.mustreceivethisinformationassoonaspossibleinordertomakethenecessary preparationsfortheemergency treatmentoftheworker.ThehospitalphonenumbersarelistedintheEmergencyTelephoneBook.
J:\ADMSRVS\TECH PUB\10\10S0119.DOC
--
GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19 EMERGENCYPLANPROCEDURE IPage:86.3.4TheRPSupervisor/Shift leadHP(OSCRadChern Coordinator) receiving theinitialinformation mustnotifythehospitalandprovidethefollowing information assoonaspossible.
a.Nameofinjuredworker(s) b.Extentofinjuries c.Contaminationlevelsoninjuredworker(s),ifapplicabled.Expected arrivaltimeathospital,ifknown.6.3.5GGNSpersonnelshould PERFORMthefollowingenroutetothehospital:*AfriskerisnormallymaintainedintheOnsiteAmbulance*Surveysmaybelimitedorimpracticalduetotheextentofinjuriesreceivedbytheworker.
a.PERFORMadetailedcontamination surveyoftheinjuredworkeriftheinjuryoccurredina RadiologicallyControlledArea.6.4OffsiteMedicalFacilities6.4.1TheRadiationProtection Supervisor/ShiftLeadHP(OSCRadChem Coordinator) isresponsible fordeterminingwhichmedicalfacilitytouse.Facilitiesavailableforuseinclude:a.ClaiborneCountyHospitalb.RiverRegionMedicalCenter 6.4.2AttachmentIandIIareusedto determine transportationroutestothemedical facilities.
J:\AOM_SRVS\TECH_PUB\lO\lOSOl19:00C GRANDGULFNUCLEARSTATION ITitle:Personnel InJuryINo.:10-8-01-19EMERGENCYPLANPROCEDURE IPage:96.4.3Processforselectinghospitalfacilitiesduringnon-radiologicalemergenciesis:a.Non-contaminated,non-lifethreatening:RiverRegionMedicalCenter,orClaiborneCountyHospital.StreetClinicinVicksburgisrecommendedwhereapplicable.b.Non-contaminated,lifethreatening-transporttoClaiborneCounty Hospital.c.PlantSafetyandEMTpersonnelmayalsoauthorizehospitallocationsduringnon-radiologicalemergenciesusingtheguidelinesabove.6.4.4Contaminatedpersonnelwithminorormajorinjuriesshouldbetransportedtooneofthemedicalfacilitiesidentifiedin6.4.1.6.4.5Patientsmustbedeliveredtohospitalfacilitiesasfollows:a.AllinjuredworkerswhoarenotcontaminatedshouldbetransporteddirectlytothehospitalEmergencyRoom.b.Contaminatedpersonnelshouldbetransportedtothehospital Radiation Emergency Area.6.4.6Whenacontaminatedinjuredworkeristransportedtothehospital,GGNSpersonnelatthehospitalshouldprovidethefollowingsupport,ifavailable:a.PROVIDEthephysicianwithallavailableinformationconcerningtheaccidentandthecontaminationhazardspresent,uponrequest.
b.ASSISTthehospitalstaff,ifpossible.
.c,COORDINATEthecollectionanddisposalofcontaminatedwaste materials.
d.COLLECTOffsiteambulancecrewdosimetryandPERFORMcontaminationsurveyofambulance.
ARRANGEfordecontamination,if necessary.6.5HospitalPreparationtoReceivePatients6.5.1ThehospitalroomREA(RadiationEmergencyArea)isnormallysetupby hospitalp.ersonnelbeforethearrivalofthepatient.
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC GRANDGULF NUCLEARSTATIONEMERGENCY PLANPROCEDURE 10-S-01-19 Attachment IRevision:021Page1of1DIRECTIONS TOCLAIBORNE COUNTYHOSPITALG,:G1NSI{GrandGulfRoad DIRECTIONS:TakeHwy61Sto McCombAvenue(StateRoad547).GoEaston547andthehospitalisonyourleft.The entrancetotheRadiation EmergencyAreaisthroughthe Emergency RoomEntranceontheNorthendofthe hospitalJ:\ADM_SRVS\TECH_PUB\10\10S0119.DOC IIIIIII IIIPort:GibsonII IIIIHWY462HWY18III:Claiborne:CountyIHospitalo.llmAve GRANDGULF NUCLEARSTATION.EMERGENCY PLANPROCEDURE 10-S-01-19Revision:021 Attachment IIPage1of1DIRECTIONSTORIVERREGION MEDICALCENTERTakeUS61Northpast CulkinAve.Youwillseethe hospitalonyourright.The Emergency RoomentranceisontheSouthsideofthehospital.
ThedoortotheDecontaminationRoomistothe rightoftheER.entrance.
RiverRegion.A.-f----
MedicalCenter
---.\DIRECTIONS:
J:\ADM_SRVS\TECH_PUB\10\10S0119.DOC ATTACHMENT 9.1SHEET1OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartI.Description ofActivityBeingReviewed(eventoraction,orseriesofactionsthatmayresultinachangetotheemergencyplanoraffecttheimplementationoftheemergencyplan):
Revision021:1.Changestoreporting emergencies andControlRoomactionstobeconsistent withManagement Standard#20.2.AddedMedicalFacility/Site Nursetosection2.3asanoptionforpersonnel requiring minorfirstaid,sincethisfacility/position ismannedduringoutages.3.AddedPlantOccupational HealthNursetosection6.4.3listofpersonnel whomayauthorize hospitalfacilities totransport patientsto.Editorial Changes:4.Addreference toManagement Standard#20-Operating Hard-Card, ControlRoomActionsforMedicalEmergency.
(Reference CR-GGN-2016-2247 CA#2)5.ChangedthetitleRiverRegionHospitaltoMeritHealthRiverRegionduetoachangeinthefacilityname.PartII.ActivityPreviously Reviewed?IsthisactivityfullyboundedbyanNRCapproved10CFR50.90submittal orAlertandNotification SystemDesignReport?IfYES,identifyboundingsourcedocumentnumber/approval reference andensurethebasisforconcluding thesourcedocumentfullyboundstheproposedchangeisdocumented below:Justification:
DBoundingdocumentattached(optional)
DYES50.54(q)(3)
Evaluation isNOTrequired.
Enterjustification belowandcompletePartVI.t81NOContinuetonextpartPartIII.Applicability ofOtherRegulatory ChangeControlProcessesCheckifanyotherregulatorychangeprocessescontroltheproposed activity.(RefertoEN-L1-100)NOTE:Forexample,whenadesignchangeistheproposedactivity,consequentialactionsmayincludechangestootherdocumentswhichhaveadifferentchangecontrolprocessandareNOTtobeincludedinthis50.54(q)(3)
Screening.
APPLICABILITY CONCLUSIONIftherearenocontrollingchangeprocesses,continuethe50.54(q)(3)Screening.
DOneormorecontrollingchangeprocessesareselected,however,someportionoftheactivityinvolvestheemergencyplanoraffectstheimplementationoftheemergencyplan;continuethe50.54(q)(3)Screeningforthatportionoftheactivity.Identifytheapplicablecontrollingchangeprocessesbelow.
oOneormorecontrollingchangeprocessesareselectedandfullyboundsallaspectsoftheactivity.
50.54(q)(3)
Evaluation isNOTrequired.IdentifycontrollingchangeprocessesbelowandcompletePart VI.CONTROLLINGCHANGEPROCESSES EN-EP-305 REV3 ATTACHMENT 9.1SHEET2OF510CFR50.54(q),
SCREENING Procedure/Document Number:10-5-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartIV.Editorial ChangeDYESt8JNO50.54(q)(3)ContinuetonextIsthisactivityaneditorialortypographicalchangesuchasformatting,paragraph Evaluation ispartnumbering,spelling,orpunctuationthatdoesnotchangeintent?
NOTrequired.
Justification:
Changes#4&5arereferencechangesandareconsiderededitorial EnterjustificationandchangesaccordingtoEN-EP-305andEN-AD-101.NoischeckedattherightbecausecompleteParttheremainingchangesarenon-editorial.
VI.PartV.Emergency PlanningElement/Function Screen(Associated10CFR50.47(b)planningstandardfunctionidentifiedinbrackets)Doesthisactivityaffectanyofthefollowing,includingprogramelementsfromNUREG-0654/FEMAREP-1SectionI/?
1.Responsibility foremergency responseisassigned.
[1]D2.Theresponseorganizationhasthestaffto respondandtoaugmentstaffonacontinuingbasis(24/7 Dstaffing) inaccordancewiththeemergencyplan.[1]3.Theprocessensuresthatonshiftemergency responseresponsibilities arestaffedandassigned.[2]
D4.Theprocessfortimelyaugmentation ofonshiftstaffisestablished andmaintained.
[2]D5.Arrangements forrequestingandusingoffsiteassistancehavebeenmade.[3]
D6.StateandlocalstaffcanbeaccommodatedattheEOFin accordancewiththeemergencyplan.[3]DI7.Astandardschemeofemergency classificationandactionlevelsisinuse.[4]
D8.Procedures fornotificationofStateandlocal governmental agenciesarecapableofalertingthemof Dthedeclaredemergency within15minutesafterdeclarationofanemergency andproviding follow-upnotifications.
[5]9.Administrative andphysicalmeanshavebeenestablished foralertingandproviding promptDinstructionstothepublicwithintheplume exposurepathway.[5]10.ThepublicANSmeetsthedesignrequirements ofFEMA-REP-10,GuideforEvaluationofAlertand DNotification SystemsforNuclearPowerPlants,orcomplieswiththelicensee's FEMA-approved ANSdesignreportandsupporting FEMAapprovalletter.[5]
11.Systemsareestablished forpromptcommunication amongprincipal emergency responseDorganizations.
[6],12.Systemsareestablished forpromptcommunication toemergency responsepersonnel.
[6]D13.Emergency preparedness information ismadeavailabletothepubliconaperiodicbasiswithinthe 0plumeexposurepathwayemergency planningzone(EPZ).[7]
14.Coordinated dissemination ofpublicinformation duringemergencies isestablished.
[7]*015.Adequatefacinties aremaintained tosupportemergency response.
[8]D16.Adequateequipment ismaintained tosupportemergency response.
[8]D17.Methods,systems,andequipment forassessment ofradioactive releasesareinuse.[9]
D18.Arangeof publicPARsisavailable forimplementation duringemergencies.
[10]D19.Evacuation timeestimatesforthepopulation locatedintheplume exposurepathwayEPZareDavailable tosupporttheformulationofPARsandhavebeen providedtoStateandlocal governmental authorities.
[10]20.Arangeofprotective actionsisavailable forplantemergency workersduringemergencies, including Dthoseforhostileactionevents.[10]
EN-EP-305 REV3 ATTACHMENT 9.1SHEET3OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel Injury21.Theresources forcontrolling radiological exposures foremergency workersareestablished.
[11]D22.Arrangements aremadeformedicalservicesforcontaminated, injuredindividuals.
[12]D23.Plansfor recoveryandreentryaredeveloped.
[13]D24.Adrilland exerciseprogram(inclUding radiological, medical,healthphysicsandotherprogramDareas)isestablished.
[14]25.Drills, exercises, andtrainingevolutions thatprovideperformance opportunities todevelop,Dmaintain, anddemonstratekeyskillsare assessedviaaformal critiqueprocessinordertoidentifyweaknesses.
[14]26.Identified weaknesses arecorrected.
[14]D27.Trainingisprovidedtoemergency responders.
[15]D28.Responsibility foremergency plandevelopment andreviewisestablished.
[16]D29.Plannersresponsible foremergency plandevelopment andmaintenance areproperlytrained.[16]DAPPLICABILITY CONCLUSION aIfnoPartVcriteriaarechecked,a50.54(q)(3)EvaluationisNOTrequired;documentthebasisforconclusionbelowandcompletePartVI.
aIfanyPartVcriteriaarechecked,completePartVIandperforma50.54(q)(3)Evaluation.BASISFORCONCLUSION Changes#4&5areeditorialchangesanddonotrequireevaluation.1.ChangestoreportingemergenciesandControlRoomactionstobeconsistentwithManagementStandard#20.ThischangerevisestheinformationtheControlRoomshouldrequestfromacallerreportingamedical emergencyandaddsadditionalinformationtothestepstakenbytheControlRoomtorespondtotheemergency.Theplanningstandardsandprogramelementsrequirethatmedicalservicesbearrangedforcontaminated,injuredworkersbuttheydonotdescribetheactionstakenbythelicenseetorespondtomedicalemergencies.Thischangedoesnoteliminateanymedicalresponseequipmentorqualificationsanddoesnotaffectoffsite arrangementsformedicalsupportincludingtransportation.Thischangewillnotaffecttheplanningstandardsorprogramelementsin10CFR50.470(b)[12]anddoesnotneedanevaluation.
EN-EP-305REV3 ATTACHMENT 9.1SHEET4OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryBASISFORCONCLUSION (continued)
- AddedMedicalFacility/SiteNursetosection2.3asanoptionforpersonnelrequiringminorfirstaid,sincethis facility/positionismannedduringoutages.
NormallyfirstaidcasesarehandledbyRPpersonnel.Duringoutages,whenwehaveanincreasein workforce, GrandGulfmaysetupasitemedicalfacility and/orstaffasitenursepositionto facilitatetheexpected increaseinfirstaid and/ormedicalemergencycases.Thisprocedurechangeallows personnelrequiringfirstaidtoreporttothesite medicalfacilityorsitenurse,ifstaffed,ratherthanlimitingthemtoreporttotheRP department.
.*Theplanningstandardsandprogramelementsin 10CFR50.47(b)[10]requirearangeof protective actionsbeavailableforplantworkers,butdoesnotspecifythelocationorstaffingofsitefirstaid stationsormedicalfacilitiessothischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].*Thischangedoesnotreducethe numberoffirstaidqualified personnelanddoesnotreducetheshiftstaffingasrequiredin 10CFRS0.47(b)[2]orNUREG06s4tableB-1.thischangewillnotaffectthesitesabilitytomeetthe requirementsof1OCFRS0.47(b)[2].*Thischangedoesnotreducethe amountorlocationofmedical equipmentandsuppliesandwillnot affectthesitesabilitytomeetthe requirements of10CFR50.47(b)[8].*Thischangedoesnotaffectthe arrangementsinplaceformedicalservicesforcontaminatedand injuredindividualsandwillnotaffectthesitesabilitytomeetthe requirementsof10CFRS0.47(b)[12].
Thischangewillnotaffectanyoftheplanningstandardsorprogram elementsin1OCFR50.470(b)anddoes notrequireanevaluation.
- AddedPlantOccupationalHealthNursetosectionlistofpersonnelwhomayauthorizewhich hospitalfacilitiestowhichpatientsaretransported.
Section6.1.3of10-S-01-19 describestheprocessforselectinq hospitals duringnon-radiological emergenciesandliststhemedical facilitiespersonnelshouldbe transported tolife-threateningorlife-threateninginjuries.ThissectionstatesthatPlantSafetyandEMT personnel mayalsoauthorize hospitallocations.Thischangeaddstheplant OccupationalHealthNursetothatgroup.Thissection onlyappliestonon-contaminated individuals.
- 10CFR50.47(b)[12]requires licenseestoensurearrangements aremadefor.medical servicesforcontaminated, injuredindividuals.
Thesearrangementswouldincludehospitals andotheroffsitemedicalfacilities.
10-S-01-19liststhesefacilitiesinsection6.4.*1.Thechange beingmadeto10-S-01-19willnotaffectthislistortheprocessfor determiningwhichhospital totransport contaminated individualsto.Thischangewillnotaffectthesitesabilityto meettherequirements of10CFR50.47(b)[12].*Theplanningstandardsandprogram elementsin10CFR50.47(b)[10]requirearangeofprotective actionsbeavailableforplantworkers,butdoesnotspecifythepositionthatshoulddeterminewhat medicalfacilitiestouse.Thischangewillnotaffectthesitesabilitytomeettherequirementsof 10CFR50.47(b)[10].Thechangesbeingmadeto 10-8-01-19willnotaffectanyof the10CFR50.47(b)planningstandardsorprogramelements.This changemaybemade withoutpriorNRCapprovalanddoesnotneeda 10CFR50.54q evaluation.
EN-EP-305REV3 ATTACHMENT 9.1SHEET5OF510CFR50.54(q)
SCREENING Procedure/Document Number:10-S-01-19 IRevision:
21Equipment/Facility/Other:
GrandGulfNuclearStationTitle:Personnel InjuryPartVI.Signatures:PreparerName(Print)
Date:/:/--.7-RichardVanDen Akker<r:4-21-16i....._(Optional)
ReviewerName(Print)
ReviewerSignature Date:ReviewerName(Print)
ReviewerSignature Date:TomSowdon Cf;4-22-2016NuclearEP ProjectManager.<<
,//"e.-/tttfJ-'tC4'l'..t:--
ApproverName(Print)
ApproverSignature Date:--:rI£'P'PEPmanagerordesignee6')2./16//7'EN-EP-305REV3