ML17263A270: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 24: Line 24:


f; l1 "l      '
f; l1 "l      '
            ,":*
   ,1
   ,1


Line 104: Line 103:
: b. Return to procedure and step in effect 9  Check Core      Exit T/Cs:
: b. Return to procedure and step in effect 9  Check Core      Exit T/Cs:
: a. Temperature    - LESS THAN 700'F        a. IF decreasing, THEN return to Step 1. IF NOT, THEN go to Step 10.
: a. Temperature    - LESS THAN 700'F        a. IF decreasing, THEN return to Step 1. IF NOT, THEN go to Step 10.
: b. Return to procedure and step      in effect
: b. Return to procedure and step      in effect CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SV PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G. MANUAL ACTION VILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
  * * * * * * * * * * * * * * * * * * * * *,* * * * * * * * * * * * * * * * * * *
                  %
CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SV PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G. MANUAL ACTION VILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
10  Reset  SZ
10  Reset  SZ
               ~e
               ~e
Line 124: Line 120:


EOP              TITLE:
EOP              TITLE:
REV' FR-C.1              RESPONSE    TO INADEQUATE CORE COOLING PAGE 9  of 15 STEP      ACTION/EXPECTED RESPONSE              RESPONSE  NOT OBTAINED
REV' FR-C.1              RESPONSE    TO INADEQUATE CORE COOLING PAGE 9  of 15 STEP      ACTION/EXPECTED RESPONSE              RESPONSE  NOT OBTAINED CAUTION o  IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
    *****************************************
CAUTION o  IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
o  A FAULTED OR RUPTURED S/G SHOULD NOT BE USED IN SUBSEQUENT STEPS UNLESS NO INTACT S/G IS AVAILABLE.
o  A FAULTED OR RUPTURED S/G SHOULD NOT BE USED IN SUBSEQUENT STEPS UNLESS NO INTACT S/G IS AVAILABLE.
NOTE:    TDAFP pump  flow control valves  fail open  on loss  of IA.
NOTE:    TDAFP pump  flow control valves  fail open  on loss  of IA.
Line 139: Line 133:


I EOP:                TITLE:
I EOP:                TITLE:
REV: 8 FR-C.1                    RESPONSE TO INADEQUATE CORE COOLING PAGE 10    of 15 STEP      ACTION/EXPECTED RESPONSE                  RESPONSE  NOT OBTAINED
REV: 8 FR-C.1                    RESPONSE TO INADEQUATE CORE COOLING PAGE 10    of 15 STEP      ACTION/EXPECTED RESPONSE                  RESPONSE  NOT OBTAINED CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 14B).
  *****************************************
CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 14B).
14    Check RCS Vent Paths:
14    Check RCS Vent Paths:
: a. Power to      PRZR PORV block valves      a. Restore power    to'lock valves
: a. Power to      PRZR PORV block valves      a. Restore power    to'lock valves

Latest revision as of 10:37, 4 February 2020

Rev 8 to EOP FR-C.1, Response to Inadequate Core Cooling.
ML17263A270
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/21/1993
From: Marlow T
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17263A269 List:
References
FR-C.1, NUDOCS 9305140047
Download: ML17263A270 (32)


Text

EOP; TITLE:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 1 of 15 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE 2'p Pv .

CATEGORY 1'0 REVIEWED BY:

isosziooa7~ ~o~goooz+

t PDR ADO PDR

f; l1 "l '

,1

EOP:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 2 of 15.

A. PURPOSE - This procedure provides actions to restore core cooling.

B. ENTRY CONDITIONS/SYMPTOMS

1. ENTRY CONDITIONS This procedure is entered from:
a. F-0.2, CORE COOLING Critical Safety Function Status Tree, on a RED condition.

EOP:

REV: 8 FR-C. 1 RESPONSE TO INADEQUATE CORE COOLING PAGE 3 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT values should be used whenever CNMT ~ressure is greater than 4 psig or CNMT radiation is greater than 10+ 5 R/hr.

1 THAN 284'erform Check RNST LeVel GREATER the following:

a. Ensure SI system aligned for cold leg recirculation using Steps 1 through 11 of ES-1.3, TRANSFER TO COLD LEG RECIRCULATION.
b. WHEN the SI system is aligned for sump recirculation, THEN go to Step 4.

EOP T1TLE0 REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 4 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

                                                                  • 4' CAUTION RHR PUMPS SHOULD NOT BE RUN LONGER THAN 1 HOUR WITHOUT CCW TO THE RHR HEAT EXCHANGERS.

2 Verify SI Pump And RHR Pump Emergency Alignment:

a. RHR pump discharge to Rx vessel a. Ensure at'east one valve open.

deluge - OPEN

~ MOV-852A

~ MOV-852B

b. Verify SI pump C - RUNNING b, Manually start pump on available bus.
c. Verify SI pump A - RUNNING c, Perform the following.
1) Ensure SI pumps B and C running.
2) Ensure SI pump C aligned to discharge line A:

o MOV-871B closed o MOV-871A open

3) Go to Step 3.
d. Verify SI pump B - RUNNING d. Perform the following:,
1) Ensure SI pumps A and C running.
2) Ensure SI pump C aligned to discharge line B:

<m r, WP

( %pl o MOV-871B open o MOV-871A closed

3) Go to Step 3.
e. Verify both SI pump C discharge e ~ Manually open valves as valves - OPEN necessary.

~ MOV-871A

~ MOV-871B

EOP I TITLE:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 5 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 3 Verify SI Pump Suction Alignment:

a. Check BAST level: a. Perform the following:

o Level - GREATER RQQl 10$ 1) Ensure at least one SI pump suction valve from RWST open.

o Annunciator B-23, BORIC ACID TANK LO LO LEVEL- ~ MOV-825A EXTINGUISHED ~ MOV-825B

2) Ensure at least one valve in each SI pump suction line from BAST closed.

~ MOV-826A or MOV-826B

~ MOV-826C or MOV-826D

3) Go to Step 4.
b. Verify SI pump suction valves b. Ensure both valves in either from BAST - OPEN flow path open.

~ MOV-826A o MOV-826A and MOV-826B

~ MOV-826B

~ MOV-826C -OR-

~ MOV-826D o MOV-826C and MOV-826D

c. Verify SI pump suction from RWST c. Manually align valves as CLOSED necessary.

~ MOV-825A

~ MOV=825B

EOP:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 6 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Verify SI Flow In Both Trains: Perform the following:

o SI line loop A and B flow a. Manually start pumps and align indicators - CHECK FOR FLOW valves as necessary.

o RHR loop flow indicator - CHECK b. Establish maximum charging flow.

FOR FLOW 5 Check RCP Support Conditions: Continue attempts to establish RCP support conditions.

a. Verify Bus 11A or 11B - ENERGIZED
b. Check other RCP support conditions (Refer to Attachment RCP START) 6 Check SI ACCUM Discharge IF SI ACCUM discharge valves closed Valves OPEN after ACCUM discharge, THEN go to Step 7. IF NOT, THEN perfone the

~ MOV-841 following:

~ MOV-865

a. Dispatch AO 'with locked valve key to locally close breakers for SI ACCUM discharge valves.

~ MOV-841, MCC C position 12F

~ MOV-865, MCC D position 12C

b. Open SI ACCUM discharge valves.

~ ACCUM A, MOV-841

~ ACCUM B, MOV-865

'efrw

'g

KOP REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 7 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Check Core Exit T/Cs LESS Go to Step 10.

THAN 1200'F 8 Check RVLIS Indication:

a. RVLIS level (no RCPs) - GREATER a. IF RVLIS increasing, THEN return THAN 438 t46% adverse CNMT) to Step 1. IF NOT, THEN go to Step 9.
b. Return to procedure and step in effect 9 Check Core Exit T/Cs:
a. Temperature - LESS THAN 700'F a. IF decreasing, THEN return to Step 1. IF NOT, THEN go to Step 10.
b. Return to procedure and step in effect CAUTION IF OFFSITE POWER IS LOST AFTER SI RESET, THEN SELECTED SV PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G. MANUAL ACTION VILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

10 Reset SZ

~e

0 EOP:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 8 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 11 Reset CI:

a. Depress CI reset pushbutton
b. Verify annunciator A-26, CNMT b. Perform the following:

ISOLATION - EXTINGUISHED

1) Reset SI.
2) Depress DI reset pushbutteu.

NOTE: This procedure should be continued while obtaining CNMT hydrogen sample in Step 12.

12 Check CNMT Hydrogen Concentration:

a. Direct HP to start CNMT hydrogen monitors as necessary
b. Hydrogen concentration - LESS b. Consult TSC to determine if THAN 0.5% hydrogen recombiners should be placed in service.

EOP TITLE:

REV' FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 9 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION o IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).

o A FAULTED OR RUPTURED S/G SHOULD NOT BE USED IN SUBSEQUENT STEPS UNLESS NO INTACT S/G IS AVAILABLE.

NOTE: TDAFP pump flow control valves fail open on loss of IA.

  • 13 Monitor Intact S/G Levels:

a.'arrow range level - GREATER a. Maintain total feed flow greater THAN 5% [25% adverse CNMT] than 200 gpm until narrow range level greater than 5% [25%

adverse CNMT] in at least one S/G.

IF total feed flow greater than 200 gpm can NOT be established, THEN perform the following:

1) Continue attempts to establish a heat sink in at least one S/G (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
2) Go to Step 23.

b, Control feed flow to maintain narrow range level between 17%

[25%'-adverse CNMT] and 50%

I EOP: TITLE:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 10 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR PRESSURE, IT SHOULD BE CLOSED AFTER PRESSURE DECREASES TO LESS THAN 2335 PSIG (REFER TO STEP 14B).

14 Check RCS Vent Paths:

a. Power to PRZR PORV block valves a. Restore power to'lock valves

- AVAILABLE unless block valve was closed to isolate an open PORV:

~ MOV-515, MCC C position 6C

~ MOV-516, MCC D position 6C

b. PORVs - CLOSED b. IF PRZR pressure less than 2335 psig, THEN manually close PORVs.

IF any PORV can NOT be closed, THEN manually close its block valve.

c. Block valves - AT LEAST ONE OPEN c. Open one block valve unless it was closed to isolate an open PORV.
d. Rx vessel head vent valves 'd. Manually close valves.

CLOSED

~ SOV-590

~ SOV=591

~ SOV 592

~ SOV<<"593

~ r

EOP: TITLE0 REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 11 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 15 Establish Condenser Steam Dump Pressure Control:

a. Verify condenser available: a. Place intact S/G ARV controller in MANUAL and go to Step 16.

o Intact S/G MSIV - OPEN o Annunciator G-15, STEAM DUMP ARMED - LIT

b. Place steam dump mode selector switch in MANUAL
c. Place steam dump controller in MANUAL NOTE: Partial'ncovering of S/G tubes is acceptable in the following steps.

16 Depressurize All Intact S/Gs To 200 PSIG:

a. Dump steam to condenser at a. Manually or locally dump steam maximum rate at maximum rate using S/G ARVs.
b. Check S/G pressure - LESS THAN b. IF S/G pressure decreasing, THEN 200 PSIG return to Step 13.

IF NOT, THEN go to Step 23.

c. Check RCS hot leg temperatures- c. IF RCS hot leg temperatures BOTH LESS THAN 400'F . decreasing, THEN return to Step 13.

P IF NOT, THEN go to Step 23.

Wa vk

d. Stop- S/G depressurization

EOP:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 12 of 1S STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check Isolated:

If SI ACCUMs Should Be

a. RCS hot leg temperatures - BOTH a. Go to Step 23.

LESS THAN 400'F

b. Verify SI reset b. Manually reset SI.
c. Close SI ACCUM discharge valves c. Vent any unisolated ACCUMs:

~ ACCUM A, MOV-841 1) Open vent valves for

~ ACCUM B, MOV-865 unisolated SI ACCUMs.

~ ACCUM A, AOV-834A

~ ACCUM B, AOV-834B

2) Open HCV-945.
d. Locally reopen breakers for MOV-841 and MOV-865 18 Stop Both RCPs 19 Dump Steam to Condenser At Manually or locally dump steam at Maximum Rate To Depressurize maximum rate using S/G ARVs.

All Intact S/Gs To Atmospheric Pressure 20 Verify SI Flow: Perform the following:

o SI liztb loop A and B flow a. Continue efforts to establish SI indicators - CHECK FOR FLOW flow.

-OR- b. Try to establish charging flow.

o RHR loop flow indicator - CHECK c. IF core exit T/Cs less than FOR FLOW 1200'F, THEN return to Step 19.

IF NOT, THEN go to Step 23.

EOP: T1TLE:

REV' FR-C. 1 RESPONSE TO INADEQUATE CORE COOLING PAGE 13 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 21 Check Core Cooling:

a. Core exit T/Cs - LESS THAN 1200'F a. Go to Step 23.
b. RCS hot leg temperatures - BOTH b. Return to Step 19.

LESS THAN 320'F

c. RVLIS level (no RCPs) - GREATER c. Return to Step 19.

THAN 68% [73% adverse CNMT]

22 Go to Appropriate Plant Procedure

a. Check RWST level - GREATER THAN a. Go to ES-1.3, TRANSFER TO COLD 28'.

LEG RECIRCULATION, Step l.

Go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step 17 NOTE: Normal conditions are desired but not required for starting the RCPs.

23 Check Core Exit T/Cs LESS Start RCPs as necessary until core THAN 1200'F exit T/Cs less than 1200'F.

IF core exit T/Cs greater than 1200'F and all available RCPs running, THEN open all PRZR PORVs and block valves. IF IA NOT available, THEN refer to Attachment .

N2 PORVS.

IF core exit T/Cs greater than 1200'F and all PRZR PORVs and block valves open, THEN open Rx vessel head vent valves.

~ SOV-590

~ SOV-591

~ SOV-592

~ SOV-593

4 I EOP:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 14 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 24 Try To Locally Depressurize Use faulted or ruptured S/G.

All Intact S/Gs To Atmospheric Pressure:

o Use intact S/G(s) ARVs

-OR-o Open TDAFW pump steam supply valve from intact S/G(s)

~ S/G A, MOV-3505A

~ S/G B, MOV-3504A

-OR-o Perform the following:

a, Open intact S/G MSIV bypass valves

b. Open both priming air ejector steam inlet valves

~ V-.3580

~ V-3581 25 Check Isolated:

If SI ACCUMs Should Be

a. RHR loop flow indicator - AT a. Return .to Step 23.

LEAST INTERMITTENT FLOW

b. Close: SI ACCUM discharge valves b. Vent any unisolated ACCUMs:

~ ACCUM A, MOV-841 1) Open vent valves for

~ ACCUM B, MOV-&65 unisolated SI ACCUMs.

~ ACCUM A, AOV-834A

~ ACCUM B, AOV-834B

2) Open HCV-945.
c. Locally reopen breakers for MOV-841 and MOV-865

EOP: TLTLE:

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 15 of 15 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Check Stopped:

If RCPs Should Be

a. Both RCS hot leg temperatures- a. Go to Step 27.

LESS THAN 320'F

b. Stop all RCPs 27 Verify SI Flow: Perform the following:

o SI line loop A and B flow a. Continue efforts to establish SI indicators - CHECK FOR FLOW flow.

-OR- b. Try to establish charging flow.

o RHR loop flow indicator - CHECK c. Return to Step 23.

FOR FLOW 28 Check Core Cooling: Return to Step 23.

o RVLIS indication - GREATER THAN 68$ f73% adverse CNMT) o RCS hot leg temperatures - LESS THAN 320'F 29 Go to Appropriate Plant Procedure I

a. Check RWST level - GREATER THAN a. Go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.

28'.

Go to,.;E;-1, LOSS OF REACTOR OR SECONDARY COOLANT, Step 17

-END-

REV: 8 FR-C.1 RESPONSE TO INADEQUATE CORE COOLING PAGE 1 of 1 FR-C.1 APPENDIX LIST TITLE PAGES

1) ATTACHMENT RCP START
2) ATTACHMENT N2 PORVS