(One intermediate revision by the same user not shown) |
Line 3: |
Line 3: |
| | issue date = 07/25/2018 | | | issue date = 07/25/2018 |
| | title = Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 | | | title = Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 |
| | author name = Brown D P | | | author name = Brown D |
| | author affiliation = Lake Engineering Co | | | author affiliation = Lake Engineering Co |
| | addressee name = | | | addressee name = |
Line 15: |
Line 15: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:U S Nuclear Regulatory Commission Attn: Document Control Room Washington, DC 20555-0001 | | {{#Wiki_filter:LAKE ENGINEERING CO. |
| | P.O. Box296 10 Austin Avenue Greenville, RI 02828 Tel: 401-949-4733 Fax: 401-949-0220 July 25, 2018 U S Nuclear Regulatory Commission Attn: Document Control Room Washington, DC 20555-0001 |
|
| |
|
| ==Subject:== | | ==Subject:== |
| * interim Notification per 10 CFR Part 21 LAKE ENGINEERING CO. P.O. Box296 10 Austin Avenue Greenville, RI 02828 Tel: 401-949-4733 Fax: 401-949-0220 July 25, 2018 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 On May 18, 2012 Lake Engineering Company (LEC) received a 55 gallon drum of SF1154 snubber fluid from Batch No.11 KL VS 146 that was manufactured in 2011. Fluid from this drum was subsequently shipped to various customers in five gallon and one gallon containers. | | * interim Notification per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 On May 18, 2012 Lake Engineering Company (LEC) received a 55 gallon drum of SF1154 snubber fluid from Batch No.11 KLVS 146 that was manufactured in 2011. Fluid from this drum was subsequently shipped to various customers in five gallon and one gallon containers. |
| On June 13, 2018 Lake Engineering Company was notified by Duane Arnold Station that, while filling a snubber in the snubber shop, soft solid material in the form of white flakes was observed in a one gallon container of fluid from the above batch. The material was reported to be similar to that observed by DAEC personnel in 2006 in SF1154 Batch No. AD965. DAEC subsequently reported the Batch AD965 anomaly in accordance with Part 21 requirements (Ref. ML070300154). | | On June 13, 2018 Lake Engineering Company was notified by Duane Arnold Station that, while filling a snubber in the snubber shop, soft solid material in the form of white flakes was observed in a one gallon container of fluid from the above batch. The material was reported to be similar to that observed by DAEC personnel in 2006 in SF1154 Batch No. AD965. DAEC subsequently reported the Batch AD965 anomaly in accordance with Part 21 requirements (Ref. ML070300154). |
| A similar anomaly was identified in March 2017 in SF1154 Batch No 14ELVS145 that was manufactured in 2014. That anomaly was reported to the NRC by Lake Engineering Company on May 1, 2017 (Ref.ML 17128A465) and was subsequently determined to not present a substantial safety hazard at the plants at which the fluid was used. Within 60 days following the date of this notification, Lake Engineering Company shall submit a final report or a second interim report documenting the results to date of our evaluation to determine whether the anomaly associated with Batch 11 KL VS 146 represents a defect which could create a substantial safety hazard at the plants at which the fluid was used. Momentive Performance Materials, the fluid manufacturer, has determined that above described solid material is a cyclic siloxane byproduct that normally exists in solution in SF1154. The apparently high concentration of the byproduct in the above batches resulted in its partial precipitation in solid form. Momentive has since implemented a process that reduces the byproduct to an undetectable level. This process shall hereafter be applied to all SF1154 fluid provided by Momentive. | | A similar anomaly was identified in March 2017 in SF1154 Batch No 14ELVS145 that was manufactured in 2014. That anomaly was reported to the NRC by Lake Engineering Company on May 1, 2017 (Ref.ML17128A465) and was subsequently determined to not present a substantial safety hazard at the plants at which the fluid was used. |
| | Within 60 days following the date of this notification, Lake Engineering Company shall submit a final report or a second interim report documenting the results to date of our evaluation to determine whether the anomaly associated with Batch 11 KLVS 146 represents a defect which could create a substantial safety hazard at the plants at which the fluid was used. |
| | Momentive Performance Materials, the fluid manufacturer, has determined that above described solid material is a cyclic siloxane byproduct that normally exists in solution in SF1154. The apparently high concentration of the byproduct in the above batches resulted in its partial precipitation in solid form. |
| | Momentive has since implemented a process that reduces the byproduct to an undetectable level. This process shall hereafter be applied to all SF1154 fluid provided by Momentive. |
| If there are any questions or if additional information is required, please contact the writer by mail or by phone using the contact information provided above or by email at dbrown@lakeengineeringri.com. | | If there are any questions or if additional information is required, please contact the writer by mail or by phone using the contact information provided above or by email at dbrown@lakeengineeringri.com. |
| DPB/d/let072518.nrc cc: P. Guay-QA Mgr. Very truly yours, LAKE ENGINEERING COMPANY D. P. Brown, P.E. President}}
| | Very truly yours, LAKE ENGINEERING COMPANY D. P. Brown, P.E. |
| | President DPB/d/let072518.nrc cc: P. Guay-QA Mgr.}} |
|
---|
Category:Deficiency Correspondence (per 10CFR50.55e and Part 21)
MONTHYEARML20296A2762020-10-0606 October 2020 Lake Engineering Co. - Third Interim Notification Per 10 CFR Part 21 - Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML19325C0942019-11-0707 November 2019 Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch ZJS1518 Final Report Per 10 CFR Part 21 ML19008A0432019-01-0404 January 2019 Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11KLVS146 ML18211A3022018-07-25025 July 2018 Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13094A1772013-03-18018 March 2013 Notice to the U.S. Nuclear Regulatory Commission of a Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters Manufactured by Aaf ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology ML12283A2462012-09-28028 September 2012 Part 21 - Fairbanks Morse Opposed Piston EDG Oil Pump Leak ML12319A0122012-09-27027 September 2012 Error in Main Steam Line High Flow Calculational Methodology ML12158A4472012-06-0606 June 2012 Part 21 60-Day Interim Report Notification - Closufailure of CRD Collet Retainer Tube/Outer Tube Weld ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML1127000672011-09-26026 September 2011 GE-Hitachi Part 21 Reportable Condition Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1025202192010-09-0303 September 2010 Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1018907392010-07-0101 July 2010 Part 21 Report Concerning Failure of Turbine Overspeed Reset Control Valve Diaphragm ML0810701722008-04-0909 April 2008 Notification of Potential Part 21 Regarding Torus Immersion/Vapor Phase Coatings ML0228102902002-09-30030 September 2002 Main Steam Line Valve Out-of-Service Final Report 2020-10-06
[Table view] Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML21225A0812021-08-0404 August 2021 Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML21014A2342020-12-0707 December 2020 Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML19199A0342019-07-0505 July 2019 Lake Engineering Co., Third Interim Notification Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. ZJS1518 ML19071A1122019-03-0101 March 2019 Lake Engineering Co., Corrected Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 11KLVS146 Final Report, Per 10 CFR Part 21 ML18295A1992018-09-24024 September 2018 Lake Engineering - Second Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11KLVS146 ML18211A3022018-07-25025 July 2018 Interim Notification Per 10 CFR Part 21, Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 ML17243A1362017-08-28028 August 2017 Fisher Information Notice, (FIN) 2017-04 - Erroneous Rotary Seating Torque Calculation in Flowscanner Software ML17212A6282017-07-24024 July 2017 Lake Engineering Co. - Potentially Degraded Snubber SF1154 Hydraulic Fluid Second - Interim Notification Per 10 CFR Part 21 ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities ML14210A0102014-07-23023 July 2014 Part 21 - Unseating of Valve Spring on Scram Solenoid Pilot Valve ML14204A7072014-07-23023 July 2014 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Unseating of Valve Spring on SSPV ML14204A7082014-07-23023 July 2014 Enclosure 2, Description of Closure Evaluation, Non-Proprietary Information - Class I (Public) ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13079A3202013-03-18018 March 2013 Notification of Potential Part 21 Interim Report Re Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air Filters ML13064A0122013-02-25025 February 2013 Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve ML13042A0962013-02-0808 February 2013 Completed Evaluation of Part 21 Potentially Reportable Condition Notification: Error in Main Steam Line High Flow Calculational Methodology ML13044A0752013-02-0808 February 2013 Part 21 - Completed Evaluation for Potential Error in Main Steam Line High Flow Calculational Methodology ML12352A1232012-12-13013 December 2012 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12348A1362012-12-13013 December 2012 Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers ML12347A3082012-12-12012 December 2012 Part 21 60-Day Interim Report Notification: Error in Main Steam Line High Flow Calculational Methodology ML12283A2462012-09-28028 September 2012 Part 21 - Fairbanks Morse Opposed Piston EDG Oil Pump Leak ML12319A0122012-09-27027 September 2012 Error in Main Steam Line High Flow Calculational Methodology ML12163A1302012-06-0606 June 2012 Part 21 Report - Failure of CRD Collet Retainer Tube/Outer Tube Weld ML12158A4472012-06-0606 June 2012 Part 21 60-Day Interim Report Notification - Closufailure of CRD Collet Retainer Tube/Outer Tube Weld ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12058A1412012-02-23023 February 2012 Part 21 Report - Rosemount Nuclear Instruments, Inc., Pressure Transmitter with Nonzero Based Calibrations ML12040A2832012-02-0707 February 2012 Notification of Potential Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML12038A0282012-02-0202 February 2012 Failure of CRD Collet Retainer Tube/Outer Tube Weld ML12032A2402012-02-0101 February 2012 Notification of Potential Part 21 - 60-Day Interim Report Notification: Failure of CRD Collet Retainer Tube/Outer Tube Weld ML11228A0842011-08-12012 August 2011 Notification of Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1122401422011-08-11011 August 2011 Part 21 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML11140A0872011-05-13013 May 2011 Sor Event 46821 Evaluation of Deviation for Defect ML11126A0152011-05-0404 May 2011 Sor, Inc., Pressure Switch with Possible Sub-Standard Electrical Lead Terminations ML1104800542011-02-15015 February 2011 Notification of Potential Part 21 Reportable Condition: Crack Indications in Marathon Control Rod Blades ML1104604872011-02-15015 February 2011 Notification of Potential Part 21 Reportable Condition Re Design Life of D and s Lattice Marathon Control Blades ML1035100312010-12-15015 December 2010 Notification of Potential Part 21 Report Concerning Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1035001742010-12-15015 December 2010 Notification of Potential Part 21 Re 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1030601022010-10-29029 October 2010 Notification of Potential Part 21 Transfer of Information Concerning Control Components Inc. (CCI) Drag Valves ML1029305052010-10-20020 October 2010 GE Hitachi Nuclear Energy - Notification of Potential Part 21 60-Day Interim Report: Crack Indications in Marathon Control Rod Blades ML1029502812010-10-20020 October 2010 Part 21 Notification - Crack Indications in Marathon Control Rod Blades ML1027300632010-09-27027 September 2010 Notification of Potential Part 21 Report Concerning Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1027006142010-09-27027 September 2010 Part 21 60-Day Interim Report Notification: Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance ML1025202192010-09-0303 September 2010 Part 21 - Failure to Include Seismic Input in Reactor Control Blade Customer Guidance ML1018907392010-07-0101 July 2010 Part 21 Report Concerning Failure of Turbine Overspeed Reset Control Valve Diaphragm ML1018201602010-07-0101 July 2010 Notification of Potential Part 21 Reportable Condition Re Failure of HPCI Turbine Overspeed Reset Control Valve Diaphragm ML1008200592010-03-22022 March 2010 GE Hitachi Nuclear Energy, Part 21 60-Day Interim Report Notification: Failure of HPCI Turbine Overspeed Reset Control Valve Diaphragm NG-09-0608, Notification of Potential Part 21 Re Duane Arnold Energy Center Identification of Defect2009-07-30030 July 2009 Notification of Potential Part 21 Re Duane Arnold Energy Center Identification of Defect 2021-08-04
[Table view] |
Text
LAKE ENGINEERING CO.
P.O. Box296 10 Austin Avenue Greenville, RI 02828 Tel: 401-949-4733 Fax: 401-949-0220 July 25, 2018 U S Nuclear Regulatory Commission Attn: Document Control Room Washington, DC 20555-0001
Subject:
- interim Notification per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 11 KLVS146 On May 18, 2012 Lake Engineering Company (LEC) received a 55 gallon drum of SF1154 snubber fluid from Batch No.11 KLVS 146 that was manufactured in 2011. Fluid from this drum was subsequently shipped to various customers in five gallon and one gallon containers.
On June 13, 2018 Lake Engineering Company was notified by Duane Arnold Station that, while filling a snubber in the snubber shop, soft solid material in the form of white flakes was observed in a one gallon container of fluid from the above batch. The material was reported to be similar to that observed by DAEC personnel in 2006 in SF1154 Batch No. AD965. DAEC subsequently reported the Batch AD965 anomaly in accordance with Part 21 requirements (Ref. ML070300154).
A similar anomaly was identified in March 2017 in SF1154 Batch No 14ELVS145 that was manufactured in 2014. That anomaly was reported to the NRC by Lake Engineering Company on May 1, 2017 (Ref.ML17128A465) and was subsequently determined to not present a substantial safety hazard at the plants at which the fluid was used.
Within 60 days following the date of this notification, Lake Engineering Company shall submit a final report or a second interim report documenting the results to date of our evaluation to determine whether the anomaly associated with Batch 11 KLVS 146 represents a defect which could create a substantial safety hazard at the plants at which the fluid was used.
Momentive Performance Materials, the fluid manufacturer, has determined that above described solid material is a cyclic siloxane byproduct that normally exists in solution in SF1154. The apparently high concentration of the byproduct in the above batches resulted in its partial precipitation in solid form.
Momentive has since implemented a process that reduces the byproduct to an undetectable level. This process shall hereafter be applied to all SF1154 fluid provided by Momentive.
If there are any questions or if additional information is required, please contact the writer by mail or by phone using the contact information provided above or by email at dbrown@lakeengineeringri.com.
Very truly yours, LAKE ENGINEERING COMPANY D. P. Brown, P.E.
President DPB/d/let072518.nrc cc: P. Guay-QA Mgr.