{{#Wiki_filter:TECHNICAL SPECIFICATIONS TASK FORCEA JOINT OWNERS GROUP ACTIVITYTSTF
{{#Wiki_filter:TECHNICAL SPECIFICATIONS TASK FORCE TSTF                                          A JOINT OWNERS GROUP ACTIVITY DATE                                                          DRAFT TSTF-17-01 REVISION 3 PROJ0753 Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001


change to the, as defined in NEI 06-09-A, Appendix A,
==SUBJECT:==
Response to NRC Questions on TSTF-505-A, "Provide Risk-Informed Extended Completion Times"


or more
==Reference:==
Letter from T. McGinty and A. Boland (NRC) to Technical Specifications Task Force (TSTF), "Issues with Technical Specifications Task Force Traveler TSTF-505, Revision 1, 'Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b'," dated November 15, 2016 In the referenced letter, the NRC raised concerns with approved TSTF traveler, TSTF-505-A, Revision 1, "Provide Risk-Informed Extended Completion Times." The NRC published in the Federal Register a notice of availability for the Model Safety Evaluation (SE) for plant-specific adoption of TSTF traveler TSTF-505, Revision 1, on March 15, 2012. Currently, several licensees have License Amendment Requests (LARs) under NRC review to adopt risk-informed Completion Times.
On December 13, 2016, the TSTF and the Nuclear Energy Institute (NEI) met with the NRC to discuss the NRC's concerns. Most of the NRC concerns were related to proposed Technical Specifications (TS) Actions related to all trains of a TS required system being inoperable. The industry proposed the following short-term and long-term actions to resolve the NRC concerns:
: 1. The industry will pursue development of a companion traveler for TSTF-505-A that addresses the NRC issues with Actions related to inoperability of all trains of a TS required system. Following approval, plants that have adopted TSTF-505-A without these Actions could submit a LAR to adopt the companion traveler. Following NRC approval of the companion traveler, plants that have not adopted TSTF-505-A can adopt TSTF-505-A and the companion traveler in a single LAR.
: 2. TSTF-505-A allows licensees to choose which Action changes are included in their LAR.
The TSTF will recommend to the industry that until the companion traveler is approved by the NRC, licensees submitting LARs to adopt TSTF-505 follow the guidance in the attachments to this letter. Actions related to the inoperability of all trains of a TS required system should not be included in LARs submitted prior to approval of the companion traveler. Omitting these Actions and incorporating the other changes recommended in the 11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Administration by EXCEL Services Corporation


or both
TSTF-17-01 DATE attachments to this letter should allow timely approval of LARs. Attachment 1 contains a list of the Actions revised by TSTF-505-A that should be omitted in LARs submitted prior to approval of the companion traveler. Attachment 1 also includes conforming changes to the TSTF-505-A Section 1.3 TS example and the TS Section 5.5 Administrative Controls program. Attachment 2 contains a list of Actions revised by TSTF-505-A that have conditions on their inclusion in a plant-specific LAR. Attachment 3 contains a revised Mode Application for requesting adoption of TSTF-505-A.
: 3. The proposed actions only apply to future submittals. The licensees with LARs currently under NRC review will decide how to proceed.
The TSTF requests that the NRC rescind the suspension of the approval of TSTF-505-A, Revision 1, and accept LARs to adopt TSTF-505-A that follow the recommendations in the attachments to this letter.
Should you have any questions, please do not hesitate to contact us.
James R. Morris (PWROG/W)                              Lisa L. Williams (BWROG)
Otto W. Gustafson (PWROG/CE)                          Jordan Vaughan (PWROG/B&W)
Jason P. Redd (APOG)
Enclosure cc:    Mirella Gavrilas, Director of the Division of Safety Systems Anne T. Boland, Director of the Division of Operating Reactor Licensing Jennifer Whitman, Acting Chief of the Technical Specifications Branch Michelle Honcharik, Technical Specifications Branch


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification                      Specification Title                      Notes 1.3                      Completion Times                              See attached recommended changes Action 3.3.1.C            RPS Instrumentation                            Do not include Action 3.3.2.A            Reactor Protection System (RPS) Manual Reactor Do not include.
Trip Action 3.3.5.B            ESFAS Instrumentation                          Do not include Action 3.3.6.B            ESFAS Manual Initiation                        Do not include Action 3.3.11.D          EFIC System Instrumentation                    Do not include Action 3.3.13.B          EFIC Logic                                    Do not include Action 3.3.14.B          EFIC-EFW- Vector Valve Logic                  Do not include Action 3.4.10.A          Pressurizer Safety Valves                      Do not include.
Action 3.4.14.C          RCS Pressure Isolation Valve (PIV) Leakage    Do not include.
Action 3.5.1.A            CFTs                                          Do not include Action 3.5.1.B            CFTs                                          Do not include Action 3.5.1.C            CFTs                                          Do not include Action 3.5.2.C            ECCS - Operating                              Do not include Action 3.5.3.B            ECCS - Shutdown                                Do not include.
Action 3.5.4.A            BWST                                          Do not include Action 3.5.4.B            BWST                                          Do not include Action 3.6.3.B            Containment Isolation Valves                  Do not include Action 3.6.3.D            Containment Isolation Valves                  Do not include Action 3.6.6.F            Containment Spray and Cooling Systems          Do not include Action 3.7.2.C            MSIVs                                          Do not include Action 3.7.4.B            AVVs                                          Do not include.
Action 3.7.5.C            EFW System                                    Do not include Action 3.7.6.A            CST                                            Do not include.
Action 3.7.8.B            SWS                                            Do not include Page 1


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification                      Specification Title              Notes Action 3.7.9.C            UHS                                    Do not include Action 3.7.11.B          CREVS                                  Do not include Action 3.8.1.E            AC Sources - Operating                Do not include Action 3.8.1.G            AC Sources - Operating                Do not include Action 3.8.4.A.1          DC Sources - Operating                Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D            DC Sources - Operating                Do not include Action 3.8.7.B            Inverters - Operating                  Do not include Action 3.8.9.D            Distribution Systems - Operating      Do not include 5.5.18                    Risk Informed Completion Time Program  See attached recommended changes Page 2


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                    Specification Title                  Notes 1.3                        Completion Times                      See attached recommended changes Action 3.3.1.C            RTS Instrumentation                    Do not include Action 3.3.1.E            RTS Instrumentation                    Do not include Action 3.3.1.G            RTS Instrumentation                    Do not include Action 3.3.1.I            RTS Instrumentation                    Do not include Action 3.3.1.Q            RTS Instrumentation                    Do not include Action 3.3.1.S            RTS Instrumentation                    Do not include Action 3.3.1.T            RTS Instrumentation                    Do not include Action 3.3.1.V            RTS Instrumentation                    Do not include Action 3.3.1.W            RTS Instrumentation                    Do not include Action 3.3.1.Z            RTS Instrumentation                    Do not include Action 3.3.1.CC            RTS Instrumentation                    Do not include Action 3.3.1.EE            RTS Instrumentation                    Do not include Action 3.3.1.JJ            RTS Instrumentation                    Do not include Action 3.3.2.C            ESFAS Instrumentation                  Do not include Action 3.3.2.E            ESFAS Instrumentation                  Do not include Action 3.3.2.G            ESFAS Instrumentation                  Do not include Action 3.3.2.I            ESFAS Instrumentation                  Do not include Action 3.3.2.K            ESFAS Instrumentation                  Do not include Action 3.3.2.M            ESFAS Instrumentation                  Do not include Action 3.3.2.O            ESFAS Instrumentation                  Do not include Action 3.3.2.Q            ESFAS Instrumentation                  Do not include Action 3.3.2.S            ESFAS Instrumentation                  Do not include Action 3.3.2.U            ESFAS Instrumentation                  Do not include Page 3


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                      Specification Title                    Notes Action 3.3.2.V            ESFAS Instrumentation                      Do not include. Required Action outside the scope of TSTF-505.
Action 3.3.9.B            BDPS                                      Do not include Action 3.4.9.C            Pressurizer                                Do not include.
Action 3.4.10.A            Pressurizer Safety Valves                  Do not include.
Action 3.4.11.E            Pressurizer Power Operated Relief Valves  Do not include.
(PORVs)
Action 3.4.11.F            Pressurizer Power Operated Relief Valves  Do not include.
(PORVs)
Action 3.4.14.C            RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.5.1.A            Accumulators                              Do not include.
Action 3.5.1.B            Accumulators                              Do not include.
Action 3.5.1.C            Accumulators                              Do not include.
Action 3.5.2.B            ECCS - Operating                          Do not include.
Action 3.5.3.B            ECCS - Shutdown                            Do not include.
Action 3.5.4.A            RWST                                      Do not include.
Action 3.5.4.B            RWST                                      Do not include.
Action 3.5.6.A            Boron Injection Tank                      Do not include.
Action 3.6.3.B            Containment Isolation Valves              Do not include.
Action 3.6.3.C            Containment Isolation Valves              Do not include.
Action 3.6.3.D            Containment Isolation Valves              Do not include.
Action 3.6.3.E            Containment Isolation Valves              Do not include.
Action 3.6.6A.E            Containment Spray and Cooling Systems      Do not include.
(Atmospheric and Dual)
Action 3.6.6B.G            Containment Spray and Cooling Systems      Do not include.
(Atmospheric and Dual)
Action 3.6.6C.B            Containment Spray System (Ice Condenser)  Do not include.
Action 3.6.6D.B            QS System (Subatmospheric)                Do not include.
Action 3.6.6E.F            RS System (Subatmospheric)                Do not include.
Page 4


ormore
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                      Specification Title                          Notes Action 3.6.9.B            Hydrogen Mixing System                          Do not include.
Action 3.6.10.C            HIS (Ice Condenser)                              Do not include.
Action 3.6.14.B            ARS (Ice Condenser)                              Do not include.
Action 3.6.15.A            Ice Bed                                          Do not include.
Action 3.6.17.A            Divider Barrier Integrity (Ice Condenser)        Do not include.
Action 3.6.17.B            Divider Barrier Integrity (Ice Condenser)        Do not include.
Action 3.6.18.A            Containment Recirculation Drains (Ice Condenser) Do not include.
Action 3.6.18.B            Containment Recirculation Drains (Ice Condenser) Do not include.
Action 3.7.2.C            MSIVs                                            Do not include.
Action 3.7.5.C            AFW System                                      Do not include.
Action 3.7.6.A            Condensate Storage Tank                          Do not include.
Action 3.7.7.B            CCW System                                      Do not include.
Action 3.7.8.B            SWS                                              Do not include.
Action 3.7.9.C            UHS                                              Do not include.
Action 3.7.11.B            CREATCS                                          Do not include.
Action 3.8.1.E            AC Sources - Operating                          Do not include Action 3.8.1.G            AC Sources - Operating                          Do not include Action 3.8.4.A.1          DC Sources - Operating                          Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D            DC Sources - Operating                          Do not include Action 3.8.7.B            Inverters - Operating                            Do not include Action 3.8.9.D            Distribution Systems - Operating                Do not include 5.5.18                    Risk Informed Completion Time Program            See attached Recommended Changes Page 5


more than two
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification                      Specification Title                  Notes 1.3                      Completion Times                          See attached recommended changes Action 3.3.4.B            ESFAS Instrumentation (Analog)            Do not include.
Action 3.3.5.B            ESFAS Logic and Manual Trip (Analog)      Do not include.
Action 3.3.5.E            ESFAS Logic and Manual Trip (Analog)      Do not include.
Action 3.3.6.A            ESFAS Logic and Manual Trip (Digital)      Do not include.
Action 3.3.6.E            ESFAS Logic and Manual Trip (Digital)      Do not include.
Action 3.4.9.C            Pressurizer                                Do not include.
Action 3.4.10.A          Pressurizer Safety Valves                  Do not include.
Action 3.4.11.E          Pressurizer Power Operated Relief Valves  Do not include.
(PORVs)
Action 3.4.11.F          Pressurizer Power Operated Relief Valves  Do not include.
(PORVs)
Action 3.4.14.C          RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.5.1.A            SITs                                      Do not include.
Action 3.5.1.B            SITs                                      Do not include.
Action 3.5.1.C            SITs                                      Do not include.
Action 3.5.2.C            ECCS - Operating                          Do not include.
Action 3.5.3.A            ECCS - Shutdown                            Do not include.
Action 3.5.4.A            RWT                                        Do not include.
Action 3.5.4.B            RWT                                        Do not include.
Action 3.6.3.C            Containment Isolation Valves              Do not include.
Action 3.6.3.E            Containment Isolation Valves              Do not include.
Action 3.6.3.F            Containment Isolation Valves              Do not include.
Action 3.6.6A.F          Containment Spray and Cooling Systems      Do not include.
(Atmospheric and Dual)
Action 3.6.6B.F          Containment Spray and Cooling Systems      Do not include.
(Atmospheric and Dual)
Action 3.6.9.B            Hydrogen Mixing System                    Do not include.
Action 3.7.2.C            MSIVs                                      Do not include.
Page 6


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification                      Specification Title              Notes Action 3.7.4.B            Atmospheric Dump Valves                Do not include.
Action 3.7.5.C            AFW System                            Do not include.
Action 3.7.6.A            Condensate Storage Tank                Do not include.
Action 3.7.7.B            CCW System                            Do not include.
Action 3.7.8.B            SWS                                    Do not include.
Action 3.7.9.C            UHS                                    Do not include.
Action 3.7.10.B          ECW                                    Do not include.
Action 3.7.12.B          CREATCS                                Do not include.
Action 3.8.1.E            AC Sources - Operating                Do not include.
Action 3.8.1.G            AC Sources - Operating                Do not include Action 3.8.4.A.1          DC Sources - Operating                Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D            DC Sources - Operating                Do not include Action 3.8.7.B            Inverters - Operating                  Do not include Action 3.8.9.D            Distribution Systems - Operating      Do not include 5.5.18                    Risk Informed Completion Time Program  See attached recommended changes Page 7


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification                      Specification Title                        Notes 1.3                        Completion Times                                See attached recommended changes Action 3.1.7.A            SLC System                                      Do not include.
Action 3.1.7.C            SLC System                                      Do not include.
Action 3.3.1.1.C          Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.4.1.B          End of Cycle Recirculation Pump Trip (EOC-      Do not include.
RPT) Instrumentation Action 3.3.4.2.B          Anticipated Transient Without Scram            Do not include.
Recirculation Pump Trip (ATWS-RPT)
Instrumentation Action 3.3.4.2.C          Anticipated Transient Without Scram            Do not include.
Recirculation Pump Trip (ATWS-RPT)
Action 3.3.5.2.C          Reactor Core Isolation Cooling (RCIC) System    Do not include.
Instrumentation Action 3.3.6.1.B          Primary Containment Isolation Instrumentation  Do not include.
Action 3.3.6.3.C          LLS Instrumentation                            Do not include.
Action 3.3.6.3.D          LLS Instrumentation                            Do not include.
Action 3.4.3.B            S/RVs                                          Do not include.
Action 3.5.1.G            ECCS - Operating                                Do not include.
Action 3.5.1.I            ECCS - Operating                                Do not include.
Action 3.6.1.3.B          PCIVs                                          Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.1.3.C          PCIVs                                          Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.2.3.B          Residual Heat Removal (RHR) Suppression Pool    Do not include.
Cooling Action 3.6.2.4.B          Residual Heat Removal (RHR) Suppression Pool    Do not include.
Spray Action 3.6.3.3.B          Containment Atmosphere Dilution (CAD) System    Do not include.
Action 3.7.1.D            Residual Heat Removal Service Water (RHRSW)    Do not include.
System Action 3.7.2.F            [PSW] System and [UHS]                          Do not include.
Action 3.7.5.B            [Control Room AC] System                        Do not include.
Action 3.8.1.E            AC Sources - Operating                          Do not include Page 8


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification                      Specification Title              Notes Action 3.8.1.G            AC Sources - Operating                Do not include Action 3.8.4.A.1          DC Sources - Operating                Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D            DC Sources - Operating                Do not include Action 3.8.7.B            Inverters - Operating                  Do not include Action 3.8.9.D            Distribution Systems - Operating      Do not include 5.5.15                    Risk Informed Completion Time Program  See attached recommended changes Page 9


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification                      Specification Title                        Notes 1.3                        Completion Times                                See attached recommended changes Action 3.1.7.A            SLC System                                      Do not include.
Action 3.1.7.C            SLC System                                      Do not include.
Action 3.3.1.1.C          Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.4.1.B          End of Cycle Recirculation Pump Trip (EOC-      Do not include.
RPT) Instrumentation Action 3.3.4.2.B          Anticipated Transient Without Scram            Do not include.
Recirculation Pump Trip (ATWS-RPT)
Instrumentation Action 3.3.4.2.C          Anticipated Transient Without Scram            Do not include.
Recirculation Pump Trip (ATWS-RPT)
Instrumentation Action 3.3.5.2.C          Reactor Core Isolation Cooling (RCIC) System    Do not include.
Instrumentation Action 3.3.6.1.B          Primary Containment Isolation Instrumentation  Do not include.
Action 3.3.6.4.B          Suppression Pool Makeup (SPMU) System          Do not include.
Instrumentation Action 3.3.6.4.C          Suppression Pool Makeup (SPMU) System          Do not include.
Instrumentation Action 3.3.6.5.B          Relief and LLS Instrumentation                  Do not include.
Action 3.4.4.B            S/RVs                                          Do not include.
Action 3.5.1.G            ECCS - Operating                                Do not include.
Action 3.5.1.I            ECCS - Operating                                Do not include.
Action 3.5.1.J            ECCS - Operating                                Do not include.
Action 3.5.1.K            ECCS - Operating                                Do not include.
Action 3.5.1.L            ECCS - Operating                                Do not include.
Action 3.6.1.3.B          Primary Containment Isolation Valves (PCIVs)    Do not include.
Action 3.6.1.3.C          Primary Containment Isolation Valves (PCIVs)    Do not include.
Action 3.6.1.3.D          Primary Containment Isolation Valves (PCIVs)    Do not include.
Action 3.6.1.7.B          Residual Heat Removal (RHR) Containment Spray  Do not include.
System Action 3.6.2.3.B          Residual Heat Removal (RHR) Suppression Pool    Do not include.
Cooling Action 3.6.2.4.A          SPMU System                                    Do not include.
Page 10


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification                      Specification Title              Notes Action 3.6.2.4.B          SPMU System                            Do not include.
Action 3.6.2.4.D          SPMU System                            Do not include.
Action 3.6.3.1.B          Drywell Cooling System Fans            Do not include.
Action 3.6.3.2.B          Drywell Purge System                  Do not include.
Action 3.6.5.1.A          Drywell                                Do not include.
Action 3.6.5.3.B          Drywell Isolation Valve[s]            Do not include.
Action 3.6.5.6.D          Drywell Vacuum Relief System          Do not include.
Action 3.6.5.6.E          Drywell Vacuum Relief System          Do not include.
Action 3.6.5.6.F          Drywell Vacuum Relief System          Do not include.
Action 3.7.1.D            [SSW] System and [UHS]                Do not include.
Action 3.7.4.B            [Control Room AC] System              Do not include.
Action 3.8.1.E            AC Sources - Operating                Do not include Action 3.8.1.G            AC Sources - Operating                Do not include Action 3.8.4.A.1          DC Sources - Operating                Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D            DC Sources - Operating                Do not include Action 3.8.7.B            Inverters - Operating                  Do not include Action 3.8.9.D            Distribution Systems - Operating      Do not include 5.5.15                    Risk Informed Completion Time Program  See attached recommended changes Page 11


oneor more two or more lines
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example
  ----------------------------------------- Reviewer's Note ------------------------------------------
Example 1.3-8 is only applicable to plants that have adopted the Risk Informed Completion Time Program.
[ EXAMPLE 1.3-8 ACTIONS CONDITION              REQUIRED ACTION                  COMPLETION TIME A. One subsystem          A.1 Restore subsystem          7 days inoperable.                to OPERABLE status.                    OR In accordance with the Risk Informed Completion Time Program B. --- NOTE ------        B.1 Restore subsystems          1 hour Not applicable              to OPERABLE when second                status.                    OR subsystem intentionally                                          In accordance with the made                                                  Risk Informed inoperable.                                            Completion Time
        -------------------                                    Program Two subsystems inoperable.
BC.Required                BC.1    Be in MODE 3.          6 hours Action and associated            AND Completion Time not met.          BC.2    Be in MODE 5.          36 hours Page 12


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example When a subsystem is declared inoperable, Condition A is entered. The 7 day Completion Time may be applied as discussed in Example 1.3-2. However, the licensee may elect to apply the Risk Informed Completion Time Program which permits calculation of a Risk Informed Completion Time (RICT) that may be used to complete the Required Action beyond the 7 day Completion Time. The RICT cannot exceed 30 days. After the 7 day Completion Time has expired, the subsystem must be restored to OPERABLE status within the RICT or Condition BC must also be entered.
If a second subsystem is declared inoperable, Condition B may also be entered. The Condition is modified by a Note stating it is not applicable if the second subsystem is intentionally made inoperable. The Required Actions of Condition B are not intended for voluntary removal of redundant subsystems from service. The Required Action is only applicable if one subsystem is inoperable for any reason and the second subsystem is found to be inoperable, or if both subsystems are found to be inoperable at the same time. If Condition B is applicable, at least one subsystem must be restored to OPERABLE status within 1 hour or Condition C must also be entered. The licensee may be able to apply a RICT to extend the Completion Time beyond 1 hour if the requirements of the Risk Informed Completion Time Program are met. If two subsystems are inoperable and Condition B is not applicable (i.e., the second subsystem was intentionally made inoperable), LCO 3.0.3 is entered as there is no applicable Condition.
The Risk Informed Completion Time Program requires recalculation of the RICT to reflect changing plant conditions. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
If the 7 day Completion Time clock of Condition A or the 1 hour Completion Time clock of Condition B have has expired and subsequent changes in plant condition result in exiting the applicability of the Risk Informed Completion Time Program without restoring the inoperable subsystem to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start.
If the RICT expires or is recalculated to be less than the elapsed time since the Condition was entered and the inoperable subsystem has not been restored to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start. If the inoperable subsystems are restored to OPERABLE status after Condition BC is entered, Conditions A, B, and BC are exited, and therefore, the Required Actions of Condition BC may be terminated. ]
Page 13


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program
[ 5.5.18  Risk Informed Completion Time Program This program provides controls to calculate a Risk Informed Completion Time (RICT) and must be implemented in accordance with NEI 06-09-A, Revision 0, "Risk-Managed Technical Specifications (RMTS) Guidelines." The program shall include the following:
: a. The RICT may not exceed 30 days;
          --------------------------------- REVIEWER'S NOTE ----------------------------------
The Risk Informed Completion Time is only applicable in MODES supported by the Licensees PRA. Licensee's applying the RICT Program to MODES other than Modes 1 and 2 must demonstrate that they have the capability to calculate a RICT in those MODES or that the risk indicated by their MODE 1 and 2 PRA model is bounding with respect to the lower MODE conditions.
: b.      A RICT may only be utilized in MODE 1, 2 [, and 3, and MODE 4 while relying on steam generators for heat removal];
: c.      When a RICT is being used, any change to the plant configuration, as defined in NEI 06-09-A, Appendix A, change within the scope of the Risk Informed Completion Time Program must be considered for the effect on the RICT.
: 1. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration.
: 2. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
: 3. Revising the RICT is not required If the plant configuration change would lower plant risk and would result in a longer RICT.
: d.      Use of a RICT is not permitted for voluntary entry into a configuration which represents a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE.
: e.      Use of a RICT is permitted for emergent conditions which represent a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE if one or more of the trains are considered "PRA functional" as defined in Section 2.3.1 of NEI 06-09.]
Page 14


or more
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program
: d.      If the extent of condition evaluation for inoperable structures, systems, or components (SSCs) is not complete prior to exceeding the Completion Time, the RICT shall account for the increased possibility of common cause failure (CCF) by either:
: 1. Numerically accounting for the increased possibility of CCF in the RICT calculation; or
: 2. Risk Management Actions (RMAs) not already credited in the RICT calculation shall be implemented that support redundant or diverse SSCs that perform the function(s) of the inoperable SSCs, and, if practicable, reduce the frequency of initiating events that challenge the function(s) performed by the inoperable SSCs.
: e.      [This paragraph will describe when prior NRC approval is needed for changes to the methodology used to calculate a RICT. The wording for this provision is currently under discussion between the NRC and the industry.]
Discussion of Recommended Changes to the Risk Informed Completion Time Program
: 1. The reference to NEI 06-09 is revised to refer to the approved version, NEI 06-09-A, Revision 0.
: 2. Paragraphs d. and e. of TSTF-505 are deleted. These paragraphs discuss determining a RICT when all trains of a system are inoperable and are not applicable to the near-term submittals that are the subject of this letter.
: 3. The NRC questioned the difference between the TSTF-505 Risk Informed Completion Time (RICT) Program in paragraph 5.5.c and the NEI 06-09 Configuration Risk Management Program (CRMP). The traveler justification stated that the TS Section 5.5 RICT Program was the same as the NEI 06-09 CRMP; however, users of the TS may not have TSTF-505 available, which may lead to confusion when applying NEI 06-09 in accordance with the TS 5.5 RICT Program. The program was revised to clarify the application of the requirements.
: 4. A new paragraph d. is added addressing common cause failure considerations.
: 5. A new paragraph e. is added. The NRC's Safety Evaluation for NEI 06-09 stated:
As part of its review and approval of a licensees application requesting to implement the RMTS, the NRC staff intends to impose a license condition that will explicitly address the scope of the PRA and non-PRA methods approved by the NRC staff for use in the plant-specific RMTS program. If a licensee wishes to change its methods, and the change is outside the bounds of the license condition, the licensee will need NRC approval, via a license amendment, of the implementation of the new method in its RMTS program. The focus of the NRC staffs review and approval will be on the Page 15


Code of Federal Regulations
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program technical adequacy of the methodology and analyses relied upon for the RMTS application.
There is no legal difference between a license condition and a Technical Specification and it is less error prone to put all requirements related to calculation of a RICT in the same location.
Therefore, in lieu of a license condition, the restriction is added as paragraph e. of the program.
Page 16


****
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification        LCO Requirements and Condition                  Condition on Use 3.3.8.B      LCO: Three channels of loss of voltage Function      Licensee must justify and three channels of degraded voltage Function      that two or more EDG LOPS instrumentation per EDG shall be            channels per EDG OPERABLE.                                            inoperable is not a Condition: One or more Functions with two or        condition in which all more channels per EDG inoperable.                    required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.3.12.B      LCO: Two manual initiation switches per              Licensee must justify actuation channel for each of the following          that one or both emergency feedwater initiation and control (EFIC) channels inoperable is Functions shall be OPERABLE:                        not a condition in
: a. Steam generator (SG) A Main Feedwater (MFW) which all required Isolation,                                          trains or subsystems of
: b. SG B MFW Isolation,                              a TS required system
: c. SG A Main Steam Line Isolation,                  are inoperable or
: d. SG B Main Steam Line Isolation, and              modify the Action to
: e. Emergency Feedwater Actuation.                    not apply a RICT when Condition: One or more EFIC Function(s) with        all required trains or one or both manual initiation switches inoperable in subsystems are both actuation channels.                            inoperable. See Note 1 at the end of Attachment 2.
Page 17


*
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification        LCO Requirements and Condition            Condition on Use 3.4.9.C      LCO: The pressurizer shall be OPERABLE.        Pressurizer is typically Condition: Capacity of pressurizer heaters      not modeled in the
**
[capable of being powered by emergency power    PRA. Licensee must supply] less than limit.                        justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.5.2.B      LCO: Two ECCS trains shall be OPERABLE.        Licensee must justify Condition: One or more [ECCS] trains inoperable that one or more ECCS for reasons other than one LPI subsystem        trains inoperable is not inoperable.                                    a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable.
Page 18


******}}
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification          LCO Requirements and Condition              Condition on Use 3.6.2.C      LCO: [Two] containment air lock[s] shall be        Licensee must justify OPERABLE. Condition: One or more                  that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock    not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.6.6        LCO: Containment Spray and Cooling Systems        Licensee must justify Condition A: One containment spray train          the ability to calculate a inoperable                                        RICT for the condition, Condition C: One [required] containment cooling    including how the train inoperable.                                  system is modeled in Condition D: One containment spray train and one the PRA, whether all
[required] containment cooling train inoperable. functions of the system Condition E: Two [required] containment cooling are modeled, and, if a trains inoperable.                                surrogate is used, why that modeling is conservative.
Page 19
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification        LCO Requirements and Condition              Condition on Use 3.3.1.F      LCO: The RTS instrumentation for each Function  Licensee must justify in Table 3.3.1-1 shall be OPERABLE.            that the condition does Condition: One Power Range Neutron Flux - High  not represent the channel inoperable.                            inability to perform the safety function assumed in the FSAR given the loss of spacial distribution of the remaining Power Range detectors. The justification can include that the Actions require periodic monitoring of spacial power distribution and imposition of compensatory limits and reduced power.
3.3.1.DD      LCO: The RTS instrumentation for each Function  The licensee must in Table 3.3.1-1 shall be OPERABLE.            include information Condition: One RTB train inoperable.            regarding how the TSTF-411 conditions and limitations will be implemented (or similar conditions if TSTF-411 has not been adopted), including discussion of ATWS Mitigation System Actuation (AMSAC),
and why those actions are sufficient, including a discussion of defense in depth.
Page 20
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification        LCO Requirements and Condition                  Condition on Use 3.3.5.B      LCO: [Three] channels per bus of the loss of        Licensee must justify voltage Function and [three] channels per bus of the that two or more degraded voltage Function shall be OPERABLE.        channels per bus Condition: One or more Functions with two or        inoperable is not a more channels per bus inoperable.                    condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.3.9.A      LCO: Boron Dilution Protection System (BDPS)        BDPS is typically not Condition: One train inoperable (applicable to      modeled in the PRA.
MODES [2,] 3, 4, and 5.)                            Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.4.9.B      LCO: The pressurizer shall be OPERABLE              Pressurizer is typically Condition: One [required] group of pressurizer      not modeled in the heaters inoperable.                                  PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 21
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification          LCO Requirements and Condition              Condition on Use 3.5.2.A      LCO: Two ECCS trains shall be OPERABLE.            Licensee must justify Condition: One or more [ECCS] trains inoperable. that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
3.6.2.C      LCO: [Two] containment air lock[s] shall be        Licensee must justify OPERABLE. Condition: One or more                  that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock    not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.6.6A        LCO: Containment Spray and Cooling Systems        Licensee must justify (Atmospheric and Dual) (Credit taken for iodine    the ability to calculate a removal by the Containment Spray System)          RICT for the condition, Condition A: One containment spray train          including how the inoperable.                                        system is modeled in Condition C: One [required] containment cooling    the PRA, whether all train inoperable.                                  functions of the system Condition D: Two [required] containment cooling are modeled, and, if a trains inoperable.                                surrogate is used, why that modeling is conservative.
Page 22
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification          LCO Requirements and Condition              Condition on Use 3.6.6B        LCO: Containment Spray and Cooling Systems        Licensee must justify (Atmospheric and Dual (Credit not taken for iodine the ability to calculate a removal by the Containment Spray System)          RICT for the condition, Condition A: One containment spray train          including how the inoperable.                                        system is modeled in Condition B: One [required] containment cooling    the PRA, whether all train inoperable.                                  functions of the system Condition C: Two containment spray trains          are modeled, and, if a inoperable.                                        surrogate is used, why Condition D: One containment spray train and one  that modeling is
[required] containment cooling train inoperable. conservative.
Condition E: Two [required] containment cooling trains inoperable.
3.6.6C.A      LCO: Containment Spray System (Ice Condenser)      Licensee must justify Condition: One containment spray train            the ability to calculate a inoperable.                                        RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.6D.A      LCO: Quench Spray (QS) System                      Licensee must justify (Subatmospheric)                                  the ability to calculate a Condition: One QS train inoperable                RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 23
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification        LCO Requirements and Condition              Condition on Use 3.6.6E        LCO: Recirculation Spray (RS) System            Licensee must justify (Subatmospheric)                                the ability to calculate a Condition A: One RS subsystem inoperable.        RICT for the condition, Condition B: Two RS subsystems inoperable in    including how the one train.                                      system is modeled in Condition C: Two inside RS subsystems            the PRA, whether all inoperable                                      functions of the system Condition D: Two outside RS subsystems          are modeled, and, if a inoperable.                                      surrogate is used, why Condition E: Casing cooling tank inoperable. that modeling is conservative.
3.6.16.A      LCO: The ice condenser inlet doors, intermediate Licensee must justify deck doors, and top deck [doors] shall be        that one or more OPERABLE and closed.                            inoperable doors is not Condition: One or more ice condenser doors      a condition in which all physically restrained from opening              required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.7.4.B      LOC: [Three] Atmospheric Dump Valves (ADV)      Licensee must justify lines shall be OPERABLE.                        that two or more Condition: Two or more required ADV lines        inoperable ADVs is not inoperable                                      a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Page 24
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification        LCO Requirements and Condition              Condition on Use 3.3.6.C        LCO: [Four] channels of Loss of Voltage Function Licensee must justify (analog)      and [four] channels of Degraded Voltage Function that more than two auto-initiation instrumentation per DG shall be  channels per bus OPERABLE.                                        inoperable is not a Condition: One or more Functions with more than condition in which all two channels inoperable.                        required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.4.9.B        LCO: The pressurizer shall be OPERABLE          Pressurizer is typically Condition: One [required] group of pressurizer  not modeled in the heaters inoperable.                              PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.5.2.D        LCO: Two ECCS trains shall be OPERABLE.          Licensee must justify Condition: Less than 100% of the ECCS flow      that one or more ECCS equivalent to a single OPERABLE train available. trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
Page 25
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification        LCO Requirements and Condition                Condition on Use 3.6.2.C      LCO: [Two] containment air lock[s] shall be        Licensee must justify OPERABLE. Condition: One or more                  that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock    not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.6.6A        LCO: Containment Spray and Cooling Systems        Licensee must justify (Atmospheric and Dual) (Credit taken for iodine    the ability to calculate a removal by the Containment Spray System)          RICT for the condition, Condition A: One containment spray train          including how the inoperable.                                        system is modeled in Condition C: One containment cooling train        the PRA, whether all inoperable.                                        functions of the system Condition D: One containment spray and one        are modeled, and, if a containment cooling train inoperable.              surrogate is used, why Condition E: Two containment cooling trains        that modeling is inoperable.                                        conservative.
Page 26
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification        LCO Requirements and Condition              Condition on Use 3.6.6B        LCO: Containment Spray and Cooling Systems      Licensee must justify (Atmospheric and Dual) (Credit not taken for    the ability to calculate a iodine removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train        including how the inoperable.                                      system is modeled in Condition B: One containment cooling train      the PRA, whether all inoperable.                                      functions of the system Condition C: Two containment spray trains        are modeled, and, if a inoperable.                                      surrogate is used, why Condition D: One containment spray train and one that modeling is containment cooling train inoperable.            conservative.
Condition E: Two containment cooling trains inoperable.
Page 27
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification        LCO Requirements and Condition                Condition on Use 3.3.1.2.A    LCO: The SRM instrumentation in Table 3.3.1.2-1    Licensee must justify shall be OPERABLE.                                  that one or more Condition: One or more required SRMs                inoperable SRMs is not inoperable in MODE 2 with intermediate range        a condition in which all monitors (IRMs) on Range 2 or below                required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.2.2.B    LCO: [Three] channels of feedwater and main        Licensee must justify turbine high water level trip instrumentation shall that two or more be OPERABLE.                                        inoperable trip Condition: Two or more feedwater and main          channels is not a turbine high water level trip channels inoperable. condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Page 28
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification        LCO Requirements and Condition            Condition on Use 3.3.4.1.A    LCO: End of Cycle Recirculation Pump Trip      Licensee must justify (EOC-RPT) Instrumentation                      that one or more Condition: One or more required channels      inoperable EOC-RPT inoperable.                                    channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT given that EOC-RPT channels are not typically modeled in the PRA.
3.3.6.3.A    LCO: Low-Low Set (LLS) Instrumentation        Licensee must justify Condition: One LLS valve inoperable due to    the ability to calculate a inoperable channel(s).                        RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 29
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification        LCO Requirements and Condition                Condition on Use 3.3.8.1.A    LCO: The LOP instrumentation for each Function    Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE.              that one or more Condition: One or more channels inoperable.        channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.6.1.2.C    LCO: The primary containment air lock shall be    Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B.                                              not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Page 30
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification        LCO Requirements and Condition              Condition on Use 3.6.1.3.E    LCO: Each PCIV, except reactor building-to-      Licensee must justify suppression chamber vacuum breakers, shall be    that PCIV leakage in OPERABLE.                                        excess of the limits is Condition: One or more penetration flow paths    not a condition in with one or more containment purge valves not    which all required within purge valve leakage limits.              trains or subsystems of a TS required system are inoperable.
Licensee must justify the ability to calculate a RICT for this inoperability.
3.6.1.7.D    LCO: Each reactor building-to-suppression        Licensee must justify chamber vacuum breaker shall be OPERABLE.        that one or more Condition: Two or more lines with one or more    inoperable vacuum reactor building -to-suppression chamber vacuum  breakers on two or breakers inoperable for opening.                more lines is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.7.7.A      LCO: The Main Turbine Bypass System shall be    Licensee must justify OPERABLE.                                        the ability to calculate a OR                                              RICT for the condition, The following limits are made applicable:        including how the
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR          system is modeled in HEAT GENERATION RATE (APLHGR)," limits          the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR]; and ]                  are modeled, and, if a
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER          surrogate is used, why RATIO (MCPR)," limits for an inoperable Main    that modeling is Turbine Bypass System, as specified in the      conservative.
[COLR]. ]
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Page 31
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition            Condition on Use 3.3.1.2.A    LCO: The SRM instrumentation in Table 3.3.1.2-1 Licensee must justify shall be OPERABLE.                              that one or more Condition: One or more required SRMs            inoperable SRMs is not inoperable in MODE 2 with intermediate range    a condition in which all monitors (IRMs) on Range 2 or below.            required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT given that SRMs are not typically modeled in the PRA.
Page 32
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition              Condition on Use 3.3.4.1.A    LCO: End of Cycle Recirculation Pump Trip      Licensee must justify (EOC-RPT) Instrumentation                      that one or more Condition: One or more required channels        inoperable channels is inoperable.                                    not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.6.5.A    LCO: Relief and Low-Low Set (LLS)              Licensee must justify Instrumentation                                the ability to calculate a Condition: One trip system inoperable.          RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 33
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition                Condition on Use 3.3.8.1.A    LCO: The LOP instrumentation for each Function    Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE.              that one or more Condition: One or more channels inoperable.        channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.6.1.2.C    LCO: The primary containment air lock shall be    Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B.                                              not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Page 34
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition            Condition on Use 3.6.1.3.E    LCO: Each PCIV shall be OPERABLE.              Licensee must justify Condition: One or more penetration flow paths  that PCIV leakage in with one or more containment purge valves not  excess of the limits is within purge valve leakage limits.            not a condition in which all required trains or subsystems of a TS required system are inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.1.7.A    LCO: Residual Heat Removal (RHR) Containment  Licensee must justify Spray System                                  the ability to calculate a Condition: One RHR containment spray          RICT for the condition, subsystem inoperable.                          including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.7.4.A      LCO: Two [control room AC] subsystems shall be Licensee must justify OPERABLE.                                      the ability to calculate a Condition: One [control room AC] subsystem    RICT for the condition, inoperable.                                    including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 35
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition              Condition on Use 3.7.6.A      LCO: The Main Turbine Bypass System shall be    Licensee must justify OPERABLE.                                        the ability to calculate a OR                                              RICT for the condition, The following limits are made applicable:        including how the
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR          system is modeled in HEAT GENERATION RATE (APLHGR)," limits          the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR] and ]                    are modeled, and, if a
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER          surrogate is used, why RATIO (MCPR)," limits for an inoperable Main    that modeling is Turbine Bypass System, as specified in the      conservative.
[COLR]. ]
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Page 36
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Note 1 Some Conditions are applicable when an unspecified number of subsystems or instrument channels are inoperable, typically written as "One or more" or "Two or more". These conditions currently apply when all subsystems or channels required to be operable to perform a function are inoperable, and application of a RICT in this situation is prohibited in the near-term TSTF-505 submittals.
To address this, it is recommended that the following modification to TSTF-505 be made to the Required Actions indicated in the Attachment 2 tables for Completion Times potentially applicable when all required subsystems or channels are inoperable.
The typical Completion Time is modified by TSTF-505 to state:
72 hours (i.e., the existing Completion Time)
OR In accordance with the Risk Informed Completion Time Program It is recommended that the second Completion Time be modified with a Note, as shown below:
72 hours (i.e., the existing Completion Time)
OR
        -------------NOTE-------------
Not applicable when
[all/four/both] required channels are inoperable.
In accordance with the Risk Informed Completion Time Program The bracketed number of channels will depend on the specification. This approach retains the existing requirements and limits the use of a RICT to conditions in which the function can still be performed.
The licensee must justify that the required function can still be performed absent an additional failure when a RICT is applied.
Alternatively, the licensee may modify the Condition to only apply when at least one subsystem or channel is operable, but this approach may require creating a new Condition or modifying an existing condition to retain the current requirements, or accepting a more restrictive requirement (such a LCO 3.0.3 entry).
Page 37
 
Attachment 3 TSTF-505 Model Application
 
PROPOSED MODEL APPLICATION FOR PLANT-SPECIFIC ADOPTION OF TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B" U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555
 
==SUBJECT:==
[PLANT]
DOCKET NO. 50-[XXX]
LICENSE AMENDMENT REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT RISK INFORMED COMPLETION TIMES TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B."
 
==REFERENCE:==
Letter from the TSTF to U.S. NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'," dated DATE In accordance with the provisions of Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), [LICENSEE] is submitting a request for an amendment to the Technical Specifications (TS) for [PLANT.]
The proposed amendment would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the [DATE] letter from the TSTF to the NRC (Reference). The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399).
* Attachment 1 provides a description and assessment of the proposed change, the requested confirmation of applicability, and plant-specific verifications.
* Attachment 2 provides the existing TS pages marked up to show the proposed changes.
* Attachment 3 provides revised (clean) TS pages.
* Attachment 4 provides existing TS Bases pages marked up to show the proposed changes.
[LICENSEE] requests approval of the proposed license amendment by [DATE], with the amendment being implemented [BY DATE OR WITHIN X DAYS].
Page In accordance with 10 CFR 50.91(a)(1), "Notice for Public Comment," the analysis about the issue of no significant hazards consideration using the standards in 10 CFR 50.92 is being provided to the Commission.
In accordance with 10 CFR 50.91(b)(1), "Notice for Public Comment; State Consultation," a copy of this application, with attachments, is being provided to the designated [STATE] Official.
I declare [or certify, verify, state] under penalty of perjury that the foregoing is true and correct.
Executed on [date][Signature]
If you should have any questions regarding this submittal, please contact [NAME, TELEPHONE NUMBER].
Sincerely,
[Name, Title]
Attachments: 1. Description and Assessment
: 2. Proposed Technical Specification Changes (Mark-Up)
: 3. Revised Technical Specification Pages
: 4. Proposed Technical Specification Bases Changes (Mark-Up)
 
==Enclosures:==
: 1. List of Revised Required Actions to Corresponding PRA Functions
: 2. Information Supporting Consistency with Regulatory Guide 1.200, Revision 2.
: 3. Information Supporting Technical Adequacy of PRA Models Without PRA Standards Endorsed by Regulatory Guide 1.200, Revision 2.
: 4. Information Supporting Justification of Excluding Sources of Risk Not Addressed by the PRA Models.
: 5. Baseline CDF and LERF.
: 6. Justification of Application Of At-Power PRA Models to Shutdown Modes.
: 7. PRA Model Update Process.
: 8. Attributes of the CRMP Model.
: 9. Key Assumptions and Sources of Uncertainty.
: 10. Program Implementation
: 11. Monitoring Program
: 12. Risk Management Action Examples cc:    NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact Page ATTACHMENT 1 DESCRIPTION AND ASSESSMENT OF THE PROPOSED CHANGE License Amendment Request for Adoption of TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b"
 
==1.0    DESCRIPTION==
 
The proposed amendment would modify the Technical Specification (TS) requirements related to Completion Times (CTs) for Required Actions to provide the option to calculate a longer, risk-informed CT (RICT). A new program, the Risk-Informed Completion Time Program, is added to TS Section 5 Administrative Controls.
The methodology for using the RICT Program is described in NEI 06-09-A, "Risk-Informed Technical Specifications Initiative 4b, Risk-Managed Technical Specifications (RMTS)
Guidelines," Revision 0, which was approved by the NRC on May 17, 2007. Adherence to NEI 06-09-A is required by the RICT Program.
The proposed amendment is consistent with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the TSTF's [DATE] letter to the NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'." However, only those Required Actions described in Enclosure 1 are proposed to be changed, [which does not include all of the modified Required Actions in TSTF-505 and which includes some plant-specific Required Actions not included in TSTF-505].
2.0    ASSESSMENT 2.1    Applicability of Published Safety Evaluation
[LICENSEE] has reviewed the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. This review included a review of the NRC staffs evaluation, as well as the supporting information provided to support TSTF-505 and the safety evaluation for NEI 06-09, as well as the TSTF's [DATE] letter on TSTF-505. [As described in the subsequent paragraphs,][LICENSEE] has concluded that the technical basis presented in the TSTF-505 proposal, the associated model safety evaluation prepared by the NRC staff, as modified by the TSTF letter on TSTF-505 are applicable to [PLANT, UNIT NOS.] and support incorporation of this amendment in the [PLANT] TS. ]
2.2    Verifications and Regulatory Commitments In accordance with Section 4.0, Limitations and Conditions, of the safety evaluation for NEI 06-09-A, the following is provided:
: 1. Enclosure 1 identifies each of the TS Required Actions to which the RICT Program will apply, with a comparison of the TS functions to the functions modeled in the probabilistic risk assessment (PRA) of the structures, systems and components (SSCs) subject to those actions.
: 2. Enclosure 2 provides a discussion of the results of peer reviews and self-assessments conducted for the plant-specific PRA models which support the RICT Program, as required by Regulatory Guide (RG) 1.200 Section 4.2.
: 3. [Enclosure 3 provides a description of all PRA models used to support the RICT Program for which Nuclear Regulatory Commission endorsed standards are not available.]
[Enclosure 3 is not applicable since each PRA model used for the RICT Program is addressed using a standard endorsed by the Nuclear Regulatory Commission.]
: 4. Enclosure 4 provides appropriate justification for excluding sources of risk not addressed by the PRA models.
: 5. Enclosure 5 provides the plant-specific baseline CDF and LERF to confirm that the potential risk increases allowed under the RICT Program are acceptable.
: 6. [Enclosure 6 provides appropriate plant-specific justification for using at power PRA models in shutdown modes to which the RICT Program applies (modes 3 [and 4]).]
[Enclosure 6 is not applicable since the RICT Program is not being applied to shutdown modes.]
: 7. Enclosure 7 provides a discussion of the licensees programs and procedures that assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant.
: 8. Enclosure 8 provides a description of how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP
: 9. Enclosure 9 provides a discussion of how the key assumptions and sources of uncertainty in the PRA models were identified, and how their impact on the RICT Program was assessed and dispositioned.
: 10. Enclosure 10 provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation, including risk management action (RMA) implementation.
Page
: 11. Enclosure 11 provides a description of the implementation and monitoring program as described in NEI 06-09, Section 2.3.2, Step 7.
: 12. Enclosure 12 provides a description of the process to identify and provide RMAs.
2.3      Optional Changes and Variations
[LICENSEE is not proposing any changes, variations, or deviations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE], except as described in the TSTF letter dated [DATE].] [LICENSEE is proposing the following changes or variations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE].
These options were recognized as acceptable changes or variations in TSTF-505 and the NRC staff's model safety evaluation.]
{NOTE: If a change or variation is not identified in TSTF-505, the NRC staff's model safety evaluation, or NEI 06-09 then provide the description and justification.}
[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-505 was based. Specifically, [describe differences between the plant-specific TS numbering and/or titles (including Required Actions and programs) and the TSTF-505 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-505 to the [PLANT] TS.]
3.0      REGULATORY SAFETY ANALYSIS 3.1      No Significant Hazards Consideration Determination
[LICENSEE] has evaluated the proposed change to the TS using the criteria in 10 CFR 50.92 and has determined that the proposed change does not involve a significant hazards consideration.
[PLANT, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) and plant-specific technical specifications (TS), to modify the TS requirements related to Completion Times for Required Actions to provide the option to calculate a longer, risk-informed Completion Time. The allowance is described in a new program in Chapter 5, "Administrative Controls," entitled the "Risk-Informed Completion Time Program."
As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazards consideration is presented below:
: 1.      Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?
Page Response: No.
The proposed change permits the extension of Completion Times provided the associated risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change does not involve a significant increase in the probability of an accident previously evaluated because the change involves no change to the plant or its modes of operation. The proposed change does not increase the consequences of an accident because the design-basis mitigation function of the affected systems is not changed and the consequences of an accident during the extended Completion Time are no different from those during the existing Completion Time.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
: 2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
The proposed change does not change the design, configuration, or method of operation of the plant. The proposed change does not involve a physical alteration of the plant (no new or different kind of equipment will be installed).
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
: 3. Does the proposed change involve a significant reduction in a margin of safety?
Response: No.
The proposed change permit the extension of Completion Times provided risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change implements a risk-informed configuration management program to assure that adequate margins of safety are maintained. Application of these new specifications and the configuration management program considers cumulative effects of multiple systems or components being out of service and does so more effectively than the current TS.
Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Page Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.
 
==4.0    ENVIRONMENTAL CONSIDERATION==
 
[LICENSEE] has reviewed the environmental evaluation included in the model safety evaluation published on [DATE] ([ ] FR [ ]) as part of the Notice of Availability. [LICENSEE] has concluded that the NRC staff findings presented in that evaluation are applicable to [PLANT, NO.].
The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.
Page ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)
{provided by the licensee}
 
ATTACHMENT 3 REVISED TECHNICAL SPECIFICATION PAGES
{provided by the licensee}
 
ATTACHMENT 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES CHANGES (MARK-UP) PAGES
{provided by the licensee}
 
ENCLOSURE 1 LIST OF REVISED REQUIRED ACTIONS TO CORRESPONDING PRA FUNCTIONS
{NOTE: This enclosure provides confirmation that the PRA models include the necessary scope of structures, systems, and components (SSCs) and their functions to address each proposed application of the RICT Program to the TS Required Actions.
TS conditions with insufficient TS operable equipment to meet the specified safety function of the system, are not to be included in the application.
List each TS Required Action to which the RICT Program may be applied and, for each Required Action, describe the following:
* The TS Required Action;
* The corresponding SSC;
* Each design basis function of the SSC;
* How each design basis function is modeled in the PRA. If one of the design basis functions of an SSC or the SSC is not modeled in the PRA, describe any proposed surrogates and why the proposed surrogate adequately captures the configuration risk; and
* The success criteria used in the PRA model compared to the licensing basis criteria. The success criteria should include both train-level and component/parameter level.
Note that the above description should be at the level of the TS condition/TS Required Action (not at the LCO level only). If the TS condition/ TS Required action covers multiple SSCs or multiple design basis functions, such as in the case ESFAS Instrumentation or Containment Sprays, describe each one individually.
The enclosure should also include clear definitions of any used terms, such as train, division, loop, "subsystem," etc.
The enclosure should provide a detailed system description of TS 3.8, "Electrical Power Systems," Required Actions if the loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs.) Also, provide a description in Enclosure 12 of representative RMAs for non-uniform trains to demonstrate that the systems safety function is maintained with either train or subsystem operable.}
 
ENCLOSURE 2 INFORMATION SUPPORTING CONSISTENCY WITH REGULATORY GUIDE 1.200, REVISION 2
{NOTE: This enclosure provides information supporting the licensee evaluation of the technical adequacy of the PRA models supporting the RICT Program based on peer reviews and self-assessments against the relevant PRA standards as endorsed in the current applicable revision of RG 1.200, including consideration of staff clarifications of the standards.
Per NEI 06-09 Rev. 0, capability category II of the standards is applicable; therefore, the licensee identifies those parts of the PRAs that conform to capability categories lower than II, and provides a disposition for the RICT Program. Consistent with RG 1.200 Section 4.2, the licensee identifies and provides a discussion of the resolution of any findings and observations from the peer reviews or self-assessments.
The licensee assessment must also address the clarifications and qualifications found in RG 1.200, either by a separate discussion provided by the licensee, or by confirmation that the peer reviews or self-assessments included consideration of the clarifications and qualifications of the current applicable RG 1.200 revision.
Licensees are strongly encouraged to apply the guidance in Appendix X, "Close out of Facts and Observations," of NEI 05-04, "Process for Performing Internal Events PRA Peer Reviews Using the ASME/ANS PRA Standard, Rev 3, November 2009," NEI 07-12, "Fire Probabilistic Risk Assessment Peer Review Process Guidelines, Rev 1, June 2010," and NEI 12-13, "External Hazards PRA Peer Review Process Guidelines, Rev 0, August 2012," to close PRA peer review findings, as this will make more efficient use of the NRC and industry resources needed to develop and review of the application. }
 
ENCLOSURE 3 INFORMATION SUPPORTING TECHNICAL ADEQUACY OF PRA MODELS WITHOUT PRA STANDARDS ENDORSED BY REGULATORY GUIDE 1.200, REVISION 2
{NOTE: This enclosure provides information supporting the licensee evaluation of the PRA models supporting the RICT Program for which the relevant PRA standards are not yet endorsed in the current applicable revision of RG 1.200.
RG 1.200 Rev. 2 endorses standards for internal and external events including internal floods and fires, seismic events, and other external hazards for full power conditions.
This scope includes the relevant hazard groups applicable to a RICT Program unless the program is to apply to lower modes of operation. In this case, shutdown and transition risk PRA models may apply but are not be covered by an endorsed standard.
If applicable, the licensee should provide a detailed description of these PRA models and the basis for its determination of their technical adequacy to support the RICT Program.}
 
ENCLOSURE 4 INFORMATION SUPPORTING JUSTIFICATION OF EXCLUDING SOURCES OF RISK NOT ADDRESSED BY THE PRA MODELS
{NOTE: This enclosure identifies and provides a justification for excluding sources of risk which are not in the scope of the PRA models applied to the RICT Program.
Exclusion of risk sources determined to be insignificant to the calculation of configuration specific risk, or the use of conservative or bounding analyses for the calculation of RICTs in lieu of realistic PRA models, are described. A qualitative treatment may be sufficient if the licensee demonstrates that those risk contributions would not affect decisions in a RICT Program. The use of conservative bounding calculations in a RICT Program may also be acceptable. However, when the risk associated with a particular hazard group would affect decisions, it is the Commissions policy that risk be assessed using a PRA that meets the staff-endorsed PRA standard.
External hazards screened out from inclusion in RICT calculations should be clearly identified as such, and should be done in a manner consistent with Part 6 of the ASME ANS PRA Standard. The justification should address baseline and configuration-specific considerations.
For external hazards that are not screened out from inclusion in RICT calculations, the licensee may propose a bounding approach to address the hazard. If the bounding approach involves assuming a uniform increase in baseline risk to address the hazard, the licensee will need to address potential RICT-specific impacts by doing one of the following:
* Demonstrate in the LAR that this approach is bounding for all TS actions included in the LAR, or
* Establish a procedure to evaluate the validity of the bounding approach when calculating an RICT that is not demonstrated to be bounded in the LAR, or
* For RICTs not demonstrated to be bounded in the LAR, establish a procedure to qualitatively evaluate the impact of the specific external hazard for each RICT when calculated and apply risk management actions as appropriate. }
 
ENCLOSURE 5 BASELINE CDF AND LERF
{NOTE: This enclosure provides the plant-specific total CDF and total LERF to confirm that these are less than 10-4/year and 10-5/year, respectively. This assures that the potential risk increases allowed under the RICT Program are consistent with RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.
The licensee should provide the totals and the contributions from each hazard group (internal events, fires, floods, seismic, other external). }
 
ENCLOSURE 6 JUSTIFICATION OF APPLICATION OF AT-POWER PRA MODELS TO SHUTDOWN MODES
{NOTE: This enclosure provides a justification for the use of existing PRA models during shutdown conditions if the RICT Program is applicable in these shutdown conditions.
The at-power PRA models may potentially be applied to lower modes of operation (hot standby for PWRs, and hot shutdown for PWRs and BWRs) for some Required Actions.
If the licensee is not proposing to use the RICT Program in these modes, then this information is not required and this Enclosure should be marked "Not applicable."
Otherwise, the licensee provides a detailed justification for those Required Actions proposed to apply the RICT Program in lower modes of operation using the at-power PRA models.}
 
ENCLOSURE 7 PRA MODEL UPDATE PROCESS
{NOTE: This enclosure describes how the PRA models used in the calculation of completion times is maintained consistent with the as-built, as-operated plant.
The licensee provides a discussion of its programs and procedures to assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant. This should include a discussion of the timing of significant PRA model changes as described in NEI 06-09, Section 2.3.4, Step 7.}
 
ENCLOSURE 8 ATTRIBUTES OF THE CRMP MODEL
{NOTE: This enclosure describes how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP.
The licensee provides a description of the PRA models and CRMP used to support the RICT Program. The following specific attributes must also be addressed:
* The baseline PRA models assess the average annual risk. However, some risk is not consistent throughout the year or the operating cycle, and the PRA models used for the CRMP need to properly assess the change in risk for the existing plant conditions. For example, success criteria may be different at core beginning of life compared to end of life, or at different times of the year for room cooling systems. The licensee describes these issues and how they are addressed in the CRMP.
* The baseline PRA models may assume some configurations are not allowable, but these assumptions may not be applicable to a CRMP. The licensee describes these issues and how they are addressed in the CRMP.
* The scope of SSCs within the CRMP is provided, along with confirmation that the CRMP tools can be readily applied for each TS Required Action within the scope of the Risk-Informed Completion Time Program. The licensee should also identify and justify SSCs that are not included in the CRMP that could provide accident mitigation functions.
* The licensee describes how consistency of calculated results from the baseline PRA model and the CRMP are verified to assure the CRMP PRA models are consistent with the baseline model and updated when the baseline PRA model is updated.
* The licensee describes the quality requirements applied to the CRMP PRA models.
* The licensee describes the training and qualification programs applicable to personnel responsible for development and use of the CRMP.}
 
ENCLOSURE 9 KEY ASSUMPTIONS AND SOURCES OF UNCERTAINTY
{NOTE: This enclosure describes the key assumptions and sources of uncertainty in the PRA models, and how their impact on the RICT Program was assessed and dispositioned. Sensitivity analyses for various plant configuration cases under different assumptions should be provided to justify conclusions.}
 
ENCLOSURE 10 PROGRAM IMPLEMENTATION
{NOTE: This enclosure provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation including training of plant personnel, and specifically discusses the decision process for risk management action (RMA) implementation during extended CTs.}
 
ENCLOSURE 11 MONITORING PROGRAM
{NOTE: This enclosure describes the monitoring program for cumulative risk impacts as described in NEI 06-09, Revision 0, Section 2.3.2, Step 7. This should include a description of how the calculations are made and what actions and thresholds are applied when corrective measures are necessary due to excessive risk increases.}
 
ENCLOSURE 12 RISK MANAGEMENT ACTION EXAMPLES
{NOTE: This enclosure describes the process for identification of RMAs applicable during extended CTs, and provides examples of RMAs.
Provide example RMAs for TS 3.8 Required Actions. These should be representative examples, such as a long and short RICTs. See the Plant Vogtle April 14, 2017 RAI response (ADAMS Accession No. ML17108A253) for an example.
If the TS-required electrical power loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs,) provide a description of representative RMAs for non-uniform trains to ensure that the systems safety function is maintained with either train or subsystem inoperable. }}}

Latest revision as of 10:16, 4 February 2020

TSTF-505 Near Term Revised Draft - Clean Copy for 09/12/2017 Teleconference
ML17258A127
Person / Time
Site: Technical Specifications Task Force
Issue date: 09/12/2017
From:
Technical Specifications Task Force
To:
Office of Nuclear Reactor Regulation
Honcharik M, 301-415-1774, DSS/STSB
Shared Package
ML17258A124 List:
References
Download: ML17258A127 (62)


Text

TECHNICAL SPECIFICATIONS TASK FORCE TSTF A JOINT OWNERS GROUP ACTIVITY DATE DRAFT TSTF-17-01 REVISION 3 PROJ0753 Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Response to NRC Questions on TSTF-505-A, "Provide Risk-Informed Extended Completion Times"

Reference:

Letter from T. McGinty and A. Boland (NRC) to Technical Specifications Task Force (TSTF), "Issues with Technical Specifications Task Force Traveler TSTF-505, Revision 1, 'Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b'," dated November 15, 2016 In the referenced letter, the NRC raised concerns with approved TSTF traveler, TSTF-505-A, Revision 1, "Provide Risk-Informed Extended Completion Times." The NRC published in the Federal Register a notice of availability for the Model Safety Evaluation (SE) for plant-specific adoption of TSTF traveler TSTF-505, Revision 1, on March 15, 2012. Currently, several licensees have License Amendment Requests (LARs) under NRC review to adopt risk-informed Completion Times.

On December 13, 2016, the TSTF and the Nuclear Energy Institute (NEI) met with the NRC to discuss the NRC's concerns. Most of the NRC concerns were related to proposed Technical Specifications (TS) Actions related to all trains of a TS required system being inoperable. The industry proposed the following short-term and long-term actions to resolve the NRC concerns:

1. The industry will pursue development of a companion traveler for TSTF-505-A that addresses the NRC issues with Actions related to inoperability of all trains of a TS required system. Following approval, plants that have adopted TSTF-505-A without these Actions could submit a LAR to adopt the companion traveler. Following NRC approval of the companion traveler, plants that have not adopted TSTF-505-A can adopt TSTF-505-A and the companion traveler in a single LAR.
2. TSTF-505-A allows licensees to choose which Action changes are included in their LAR.

The TSTF will recommend to the industry that until the companion traveler is approved by the NRC, licensees submitting LARs to adopt TSTF-505 follow the guidance in the attachments to this letter. Actions related to the inoperability of all trains of a TS required system should not be included in LARs submitted prior to approval of the companion traveler. Omitting these Actions and incorporating the other changes recommended in the 11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Administration by EXCEL Services Corporation

TSTF-17-01 DATE attachments to this letter should allow timely approval of LARs. Attachment 1 contains a list of the Actions revised by TSTF-505-A that should be omitted in LARs submitted prior to approval of the companion traveler. Attachment 1 also includes conforming changes to the TSTF-505-A Section 1.3 TS example and the TS Section 5.5 Administrative Controls program. Attachment 2 contains a list of Actions revised by TSTF-505-A that have conditions on their inclusion in a plant-specific LAR. Attachment 3 contains a revised Mode Application for requesting adoption of TSTF-505-A.

3. The proposed actions only apply to future submittals. The licensees with LARs currently under NRC review will decide how to proceed.

The TSTF requests that the NRC rescind the suspension of the approval of TSTF-505-A, Revision 1, and accept LARs to adopt TSTF-505-A that follow the recommendations in the attachments to this letter.

Should you have any questions, please do not hesitate to contact us.

James R. Morris (PWROG/W) Lisa L. Williams (BWROG)

Otto W. Gustafson (PWROG/CE) Jordan Vaughan (PWROG/B&W)

Jason P. Redd (APOG)

Enclosure cc: Mirella Gavrilas, Director of the Division of Safety Systems Anne T. Boland, Director of the Division of Operating Reactor Licensing Jennifer Whitman, Acting Chief of the Technical Specifications Branch Michelle Honcharik, Technical Specifications Branch

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RPS Instrumentation Do not include Action 3.3.2.A Reactor Protection System (RPS) Manual Reactor Do not include.

Trip Action 3.3.5.B ESFAS Instrumentation Do not include Action 3.3.6.B ESFAS Manual Initiation Do not include Action 3.3.11.D EFIC System Instrumentation Do not include Action 3.3.13.B EFIC Logic Do not include Action 3.3.14.B EFIC-EFW- Vector Valve Logic Do not include Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A CFTs Do not include Action 3.5.1.B CFTs Do not include Action 3.5.1.C CFTs Do not include Action 3.5.2.C ECCS - Operating Do not include Action 3.5.3.B ECCS - Shutdown Do not include.

Action 3.5.4.A BWST Do not include Action 3.5.4.B BWST Do not include Action 3.6.3.B Containment Isolation Valves Do not include Action 3.6.3.D Containment Isolation Valves Do not include Action 3.6.6.F Containment Spray and Cooling Systems Do not include Action 3.7.2.C MSIVs Do not include Action 3.7.4.B AVVs Do not include.

Action 3.7.5.C EFW System Do not include Action 3.7.6.A CST Do not include.

Action 3.7.8.B SWS Do not include Page 1

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification Specification Title Notes Action 3.7.9.C UHS Do not include Action 3.7.11.B CREVS Do not include Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Page 2

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RTS Instrumentation Do not include Action 3.3.1.E RTS Instrumentation Do not include Action 3.3.1.G RTS Instrumentation Do not include Action 3.3.1.I RTS Instrumentation Do not include Action 3.3.1.Q RTS Instrumentation Do not include Action 3.3.1.S RTS Instrumentation Do not include Action 3.3.1.T RTS Instrumentation Do not include Action 3.3.1.V RTS Instrumentation Do not include Action 3.3.1.W RTS Instrumentation Do not include Action 3.3.1.Z RTS Instrumentation Do not include Action 3.3.1.CC RTS Instrumentation Do not include Action 3.3.1.EE RTS Instrumentation Do not include Action 3.3.1.JJ RTS Instrumentation Do not include Action 3.3.2.C ESFAS Instrumentation Do not include Action 3.3.2.E ESFAS Instrumentation Do not include Action 3.3.2.G ESFAS Instrumentation Do not include Action 3.3.2.I ESFAS Instrumentation Do not include Action 3.3.2.K ESFAS Instrumentation Do not include Action 3.3.2.M ESFAS Instrumentation Do not include Action 3.3.2.O ESFAS Instrumentation Do not include Action 3.3.2.Q ESFAS Instrumentation Do not include Action 3.3.2.S ESFAS Instrumentation Do not include Action 3.3.2.U ESFAS Instrumentation Do not include Page 3

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification Specification Title Notes Action 3.3.2.V ESFAS Instrumentation Do not include. Required Action outside the scope of TSTF-505.

Action 3.3.9.B BDPS Do not include Action 3.4.9.C Pressurizer Do not include.

Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.11.E Pressurizer Power Operated Relief Valves Do not include.

(PORVs)

Action 3.4.11.F Pressurizer Power Operated Relief Valves Do not include.

(PORVs)

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A Accumulators Do not include.

Action 3.5.1.B Accumulators Do not include.

Action 3.5.1.C Accumulators Do not include.

Action 3.5.2.B ECCS - Operating Do not include.

Action 3.5.3.B ECCS - Shutdown Do not include.

Action 3.5.4.A RWST Do not include.

Action 3.5.4.B RWST Do not include.

Action 3.5.6.A Boron Injection Tank Do not include.

Action 3.6.3.B Containment Isolation Valves Do not include.

Action 3.6.3.C Containment Isolation Valves Do not include.

Action 3.6.3.D Containment Isolation Valves Do not include.

Action 3.6.3.E Containment Isolation Valves Do not include.

Action 3.6.6A.E Containment Spray and Cooling Systems Do not include.

(Atmospheric and Dual)

Action 3.6.6B.G Containment Spray and Cooling Systems Do not include.

(Atmospheric and Dual)

Action 3.6.6C.B Containment Spray System (Ice Condenser) Do not include.

Action 3.6.6D.B QS System (Subatmospheric) Do not include.

Action 3.6.6E.F RS System (Subatmospheric) Do not include.

Page 4

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification Specification Title Notes Action 3.6.9.B Hydrogen Mixing System Do not include.

Action 3.6.10.C HIS (Ice Condenser) Do not include.

Action 3.6.14.B ARS (Ice Condenser) Do not include.

Action 3.6.15.A Ice Bed Do not include.

Action 3.6.17.A Divider Barrier Integrity (Ice Condenser) Do not include.

Action 3.6.17.B Divider Barrier Integrity (Ice Condenser) Do not include.

Action 3.6.18.A Containment Recirculation Drains (Ice Condenser) Do not include.

Action 3.6.18.B Containment Recirculation Drains (Ice Condenser) Do not include.

Action 3.7.2.C MSIVs Do not include.

Action 3.7.5.C AFW System Do not include.

Action 3.7.6.A Condensate Storage Tank Do not include.

Action 3.7.7.B CCW System Do not include.

Action 3.7.8.B SWS Do not include.

Action 3.7.9.C UHS Do not include.

Action 3.7.11.B CREATCS Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached Recommended Changes Page 5

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.4.B ESFAS Instrumentation (Analog) Do not include.

Action 3.3.5.B ESFAS Logic and Manual Trip (Analog) Do not include.

Action 3.3.5.E ESFAS Logic and Manual Trip (Analog) Do not include.

Action 3.3.6.A ESFAS Logic and Manual Trip (Digital) Do not include.

Action 3.3.6.E ESFAS Logic and Manual Trip (Digital) Do not include.

Action 3.4.9.C Pressurizer Do not include.

Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.11.E Pressurizer Power Operated Relief Valves Do not include.

(PORVs)

Action 3.4.11.F Pressurizer Power Operated Relief Valves Do not include.

(PORVs)

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A SITs Do not include.

Action 3.5.1.B SITs Do not include.

Action 3.5.1.C SITs Do not include.

Action 3.5.2.C ECCS - Operating Do not include.

Action 3.5.3.A ECCS - Shutdown Do not include.

Action 3.5.4.A RWT Do not include.

Action 3.5.4.B RWT Do not include.

Action 3.6.3.C Containment Isolation Valves Do not include.

Action 3.6.3.E Containment Isolation Valves Do not include.

Action 3.6.3.F Containment Isolation Valves Do not include.

Action 3.6.6A.F Containment Spray and Cooling Systems Do not include.

(Atmospheric and Dual)

Action 3.6.6B.F Containment Spray and Cooling Systems Do not include.

(Atmospheric and Dual)

Action 3.6.9.B Hydrogen Mixing System Do not include.

Action 3.7.2.C MSIVs Do not include.

Page 6

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification Specification Title Notes Action 3.7.4.B Atmospheric Dump Valves Do not include.

Action 3.7.5.C AFW System Do not include.

Action 3.7.6.A Condensate Storage Tank Do not include.

Action 3.7.7.B CCW System Do not include.

Action 3.7.8.B SWS Do not include.

Action 3.7.9.C UHS Do not include.

Action 3.7.10.B ECW Do not include.

Action 3.7.12.B CREATCS Do not include.

Action 3.8.1.E AC Sources - Operating Do not include.

Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Page 7

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.

Action 3.1.7.C SLC System Do not include.

Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.

Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC- Do not include.

RPT) Instrumentation Action 3.3.4.2.B Anticipated Transient Without Scram Do not include.

Recirculation Pump Trip (ATWS-RPT)

Instrumentation Action 3.3.4.2.C Anticipated Transient Without Scram Do not include.

Recirculation Pump Trip (ATWS-RPT)

Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Do not include.

Instrumentation Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.

Action 3.3.6.3.C LLS Instrumentation Do not include.

Action 3.3.6.3.D LLS Instrumentation Do not include.

Action 3.4.3.B S/RVs Do not include.

Action 3.5.1.G ECCS - Operating Do not include.

Action 3.5.1.I ECCS - Operating Do not include.

Action 3.6.1.3.B PCIVs Do not include. Required Action outside the scope of TSTF-505.

Action 3.6.1.3.C PCIVs Do not include. Required Action outside the scope of TSTF-505.

Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Do not include.

Cooling Action 3.6.2.4.B Residual Heat Removal (RHR) Suppression Pool Do not include.

Spray Action 3.6.3.3.B Containment Atmosphere Dilution (CAD) System Do not include.

Action 3.7.1.D Residual Heat Removal Service Water (RHRSW) Do not include.

System Action 3.7.2.F [PSW] System and [UHS] Do not include.

Action 3.7.5.B [Control Room AC] System Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Page 8

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification Specification Title Notes Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Page 9

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.

Action 3.1.7.C SLC System Do not include.

Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.

Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC- Do not include.

RPT) Instrumentation Action 3.3.4.2.B Anticipated Transient Without Scram Do not include.

Recirculation Pump Trip (ATWS-RPT)

Instrumentation Action 3.3.4.2.C Anticipated Transient Without Scram Do not include.

Recirculation Pump Trip (ATWS-RPT)

Instrumentation Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Do not include.

Instrumentation Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.

Action 3.3.6.4.B Suppression Pool Makeup (SPMU) System Do not include.

Instrumentation Action 3.3.6.4.C Suppression Pool Makeup (SPMU) System Do not include.

Instrumentation Action 3.3.6.5.B Relief and LLS Instrumentation Do not include.

Action 3.4.4.B S/RVs Do not include.

Action 3.5.1.G ECCS - Operating Do not include.

Action 3.5.1.I ECCS - Operating Do not include.

Action 3.5.1.J ECCS - Operating Do not include.

Action 3.5.1.K ECCS - Operating Do not include.

Action 3.5.1.L ECCS - Operating Do not include.

Action 3.6.1.3.B Primary Containment Isolation Valves (PCIVs) Do not include.

Action 3.6.1.3.C Primary Containment Isolation Valves (PCIVs) Do not include.

Action 3.6.1.3.D Primary Containment Isolation Valves (PCIVs) Do not include.

Action 3.6.1.7.B Residual Heat Removal (RHR) Containment Spray Do not include.

System Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Do not include.

Cooling Action 3.6.2.4.A SPMU System Do not include.

Page 10

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification Specification Title Notes Action 3.6.2.4.B SPMU System Do not include.

Action 3.6.2.4.D SPMU System Do not include.

Action 3.6.3.1.B Drywell Cooling System Fans Do not include.

Action 3.6.3.2.B Drywell Purge System Do not include.

Action 3.6.5.1.A Drywell Do not include.

Action 3.6.5.3.B Drywell Isolation Valve[s] Do not include.

Action 3.6.5.6.D Drywell Vacuum Relief System Do not include.

Action 3.6.5.6.E Drywell Vacuum Relief System Do not include.

Action 3.6.5.6.F Drywell Vacuum Relief System Do not include.

Action 3.7.1.D [SSW] System and [UHS] Do not include.

Action 3.7.4.B [Control Room AC] System Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Page 11

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example


Reviewer's Note ------------------------------------------

Example 1.3-8 is only applicable to plants that have adopted the Risk Informed Completion Time Program.

[ EXAMPLE 1.3-8 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One subsystem A.1 Restore subsystem 7 days inoperable. to OPERABLE status. OR In accordance with the Risk Informed Completion Time Program B. --- NOTE ------ B.1 Restore subsystems 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Not applicable to OPERABLE when second status. OR subsystem intentionally In accordance with the made Risk Informed inoperable. Completion Time


Program Two subsystems inoperable.

BC.Required BC.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Action and associated AND Completion Time not met. BC.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> Page 12

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example When a subsystem is declared inoperable, Condition A is entered. The 7 day Completion Time may be applied as discussed in Example 1.3-2. However, the licensee may elect to apply the Risk Informed Completion Time Program which permits calculation of a Risk Informed Completion Time (RICT) that may be used to complete the Required Action beyond the 7 day Completion Time. The RICT cannot exceed 30 days. After the 7 day Completion Time has expired, the subsystem must be restored to OPERABLE status within the RICT or Condition BC must also be entered.

If a second subsystem is declared inoperable, Condition B may also be entered. The Condition is modified by a Note stating it is not applicable if the second subsystem is intentionally made inoperable. The Required Actions of Condition B are not intended for voluntary removal of redundant subsystems from service. The Required Action is only applicable if one subsystem is inoperable for any reason and the second subsystem is found to be inoperable, or if both subsystems are found to be inoperable at the same time. If Condition B is applicable, at least one subsystem must be restored to OPERABLE status within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or Condition C must also be entered. The licensee may be able to apply a RICT to extend the Completion Time beyond 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> if the requirements of the Risk Informed Completion Time Program are met. If two subsystems are inoperable and Condition B is not applicable (i.e., the second subsystem was intentionally made inoperable), LCO 3.0.3 is entered as there is no applicable Condition.

The Risk Informed Completion Time Program requires recalculation of the RICT to reflect changing plant conditions. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the plant configuration change, whichever is less.

If the 7 day Completion Time clock of Condition A or the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time clock of Condition B have has expired and subsequent changes in plant condition result in exiting the applicability of the Risk Informed Completion Time Program without restoring the inoperable subsystem to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start.

If the RICT expires or is recalculated to be less than the elapsed time since the Condition was entered and the inoperable subsystem has not been restored to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start. If the inoperable subsystems are restored to OPERABLE status after Condition BC is entered, Conditions A, B, and BC are exited, and therefore, the Required Actions of Condition BC may be terminated. ]

Page 13

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program

[ 5.5.18 Risk Informed Completion Time Program This program provides controls to calculate a Risk Informed Completion Time (RICT) and must be implemented in accordance with NEI 06-09-A, Revision 0, "Risk-Managed Technical Specifications (RMTS) Guidelines." The program shall include the following:

a. The RICT may not exceed 30 days;

REVIEWER'S NOTE ----------------------------------

The Risk Informed Completion Time is only applicable in MODES supported by the Licensees PRA. Licensee's applying the RICT Program to MODES other than Modes 1 and 2 must demonstrate that they have the capability to calculate a RICT in those MODES or that the risk indicated by their MODE 1 and 2 PRA model is bounding with respect to the lower MODE conditions.

b. A RICT may only be utilized in MODE 1, 2 [, and 3, and MODE 4 while relying on steam generators for heat removal];
c. When a RICT is being used, any change to the plant configuration, as defined in NEI 06-09-A, Appendix A, change within the scope of the Risk Informed Completion Time Program must be considered for the effect on the RICT.
1. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration.
2. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the plant configuration change, whichever is less.
3. Revising the RICT is not required If the plant configuration change would lower plant risk and would result in a longer RICT.
d. Use of a RICT is not permitted for voluntary entry into a configuration which represents a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE.
e. Use of a RICT is permitted for emergent conditions which represent a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE if one or more of the trains are considered "PRA functional" as defined in Section 2.3.1 of NEI 06-09.]

Page 14

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program

d. If the extent of condition evaluation for inoperable structures, systems, or components (SSCs) is not complete prior to exceeding the Completion Time, the RICT shall account for the increased possibility of common cause failure (CCF) by either:
1. Numerically accounting for the increased possibility of CCF in the RICT calculation; or
2. Risk Management Actions (RMAs) not already credited in the RICT calculation shall be implemented that support redundant or diverse SSCs that perform the function(s) of the inoperable SSCs, and, if practicable, reduce the frequency of initiating events that challenge the function(s) performed by the inoperable SSCs.
e. [This paragraph will describe when prior NRC approval is needed for changes to the methodology used to calculate a RICT. The wording for this provision is currently under discussion between the NRC and the industry.]

Discussion of Recommended Changes to the Risk Informed Completion Time Program

1. The reference to NEI 06-09 is revised to refer to the approved version, NEI 06-09-A, Revision 0.
2. Paragraphs d. and e. of TSTF-505 are deleted. These paragraphs discuss determining a RICT when all trains of a system are inoperable and are not applicable to the near-term submittals that are the subject of this letter.
3. The NRC questioned the difference between the TSTF-505 Risk Informed Completion Time (RICT) Program in paragraph 5.5.c and the NEI 06-09 Configuration Risk Management Program (CRMP). The traveler justification stated that the TS Section 5.5 RICT Program was the same as the NEI 06-09 CRMP; however, users of the TS may not have TSTF-505 available, which may lead to confusion when applying NEI 06-09 in accordance with the TS 5.5 RICT Program. The program was revised to clarify the application of the requirements.
4. A new paragraph d. is added addressing common cause failure considerations.
5. A new paragraph e. is added. The NRC's Safety Evaluation for NEI 06-09 stated:

As part of its review and approval of a licensees application requesting to implement the RMTS, the NRC staff intends to impose a license condition that will explicitly address the scope of the PRA and non-PRA methods approved by the NRC staff for use in the plant-specific RMTS program. If a licensee wishes to change its methods, and the change is outside the bounds of the license condition, the licensee will need NRC approval, via a license amendment, of the implementation of the new method in its RMTS program. The focus of the NRC staffs review and approval will be on the Page 15

Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program technical adequacy of the methodology and analyses relied upon for the RMTS application.

There is no legal difference between a license condition and a Technical Specification and it is less error prone to put all requirements related to calculation of a RICT in the same location.

Therefore, in lieu of a license condition, the restriction is added as paragraph e. of the program.

Page 16

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification LCO Requirements and Condition Condition on Use 3.3.8.B LCO: Three channels of loss of voltage Function Licensee must justify and three channels of degraded voltage Function that two or more EDG LOPS instrumentation per EDG shall be channels per EDG OPERABLE. inoperable is not a Condition: One or more Functions with two or condition in which all more channels per EDG inoperable. required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.3.12.B LCO: Two manual initiation switches per Licensee must justify actuation channel for each of the following that one or both emergency feedwater initiation and control (EFIC) channels inoperable is Functions shall be OPERABLE: not a condition in

a. Steam generator (SG) A Main Feedwater (MFW) which all required Isolation, trains or subsystems of
b. SG B MFW Isolation, a TS required system
c. SG A Main Steam Line Isolation, are inoperable or
d. SG B Main Steam Line Isolation, and modify the Action to
e. Emergency Feedwater Actuation. not apply a RICT when Condition: One or more EFIC Function(s) with all required trains or one or both manual initiation switches inoperable in subsystems are both actuation channels. inoperable. See Note 1 at the end of Attachment 2.

Page 17

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification LCO Requirements and Condition Condition on Use 3.4.9.C LCO: The pressurizer shall be OPERABLE. Pressurizer is typically Condition: Capacity of pressurizer heaters not modeled in the

[capable of being powered by emergency power PRA. Licensee must supply] less than limit. justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.5.2.B LCO: Two ECCS trains shall be OPERABLE. Licensee must justify Condition: One or more [ECCS] trains inoperable that one or more ECCS for reasons other than one LPI subsystem trains inoperable is not inoperable. a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable.

Page 18

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be Licensee must justify OPERABLE. Condition: One or more that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock not a condition in mechanism. which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6 LCO: Containment Spray and Cooling Systems Licensee must justify Condition A: One containment spray train the ability to calculate a inoperable RICT for the condition, Condition C: One [required] containment cooling including how the train inoperable. system is modeled in Condition D: One containment spray train and one the PRA, whether all

[required] containment cooling train inoperable. functions of the system Condition E: Two [required] containment cooling are modeled, and, if a trains inoperable. surrogate is used, why that modeling is conservative.

Page 19

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification LCO Requirements and Condition Condition on Use 3.3.1.F LCO: The RTS instrumentation for each Function Licensee must justify in Table 3.3.1-1 shall be OPERABLE. that the condition does Condition: One Power Range Neutron Flux - High not represent the channel inoperable. inability to perform the safety function assumed in the FSAR given the loss of spacial distribution of the remaining Power Range detectors. The justification can include that the Actions require periodic monitoring of spacial power distribution and imposition of compensatory limits and reduced power.

3.3.1.DD LCO: The RTS instrumentation for each Function The licensee must in Table 3.3.1-1 shall be OPERABLE. include information Condition: One RTB train inoperable. regarding how the TSTF-411 conditions and limitations will be implemented (or similar conditions if TSTF-411 has not been adopted), including discussion of ATWS Mitigation System Actuation (AMSAC),

and why those actions are sufficient, including a discussion of defense in depth.

Page 20

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification LCO Requirements and Condition Condition on Use 3.3.5.B LCO: [Three] channels per bus of the loss of Licensee must justify voltage Function and [three] channels per bus of the that two or more degraded voltage Function shall be OPERABLE. channels per bus Condition: One or more Functions with two or inoperable is not a more channels per bus inoperable. condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.3.9.A LCO: Boron Dilution Protection System (BDPS) BDPS is typically not Condition: One train inoperable (applicable to modeled in the PRA.

MODES [2,] 3, 4, and 5.) Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.4.9.B LCO: The pressurizer shall be OPERABLE Pressurizer is typically Condition: One [required] group of pressurizer not modeled in the heaters inoperable. PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Page 21

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification LCO Requirements and Condition Condition on Use 3.5.2.A LCO: Two ECCS trains shall be OPERABLE. Licensee must justify Condition: One or more [ECCS] trains inoperable. that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.

3.6.2.C LCO: [Two] containment air lock[s] shall be Licensee must justify OPERABLE. Condition: One or more that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock not a condition in mechanism. which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6A LCO: Containment Spray and Cooling Systems Licensee must justify (Atmospheric and Dual) (Credit taken for iodine the ability to calculate a removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train including how the inoperable. system is modeled in Condition C: One [required] containment cooling the PRA, whether all train inoperable. functions of the system Condition D: Two [required] containment cooling are modeled, and, if a trains inoperable. surrogate is used, why that modeling is conservative.

Page 22

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems Licensee must justify (Atmospheric and Dual (Credit not taken for iodine the ability to calculate a removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train including how the inoperable. system is modeled in Condition B: One [required] containment cooling the PRA, whether all train inoperable. functions of the system Condition C: Two containment spray trains are modeled, and, if a inoperable. surrogate is used, why Condition D: One containment spray train and one that modeling is

[required] containment cooling train inoperable. conservative.

Condition E: Two [required] containment cooling trains inoperable.

3.6.6C.A LCO: Containment Spray System (Ice Condenser) Licensee must justify Condition: One containment spray train the ability to calculate a inoperable. RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.6D.A LCO: Quench Spray (QS) System Licensee must justify (Subatmospheric) the ability to calculate a Condition: One QS train inoperable RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Page 23

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification LCO Requirements and Condition Condition on Use 3.6.6E LCO: Recirculation Spray (RS) System Licensee must justify (Subatmospheric) the ability to calculate a Condition A: One RS subsystem inoperable. RICT for the condition, Condition B: Two RS subsystems inoperable in including how the one train. system is modeled in Condition C: Two inside RS subsystems the PRA, whether all inoperable functions of the system Condition D: Two outside RS subsystems are modeled, and, if a inoperable. surrogate is used, why Condition E: Casing cooling tank inoperable. that modeling is conservative.

3.6.16.A LCO: The ice condenser inlet doors, intermediate Licensee must justify deck doors, and top deck [doors] shall be that one or more OPERABLE and closed. inoperable doors is not Condition: One or more ice condenser doors a condition in which all physically restrained from opening required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.7.4.B LOC: [Three] Atmospheric Dump Valves (ADV) Licensee must justify lines shall be OPERABLE. that two or more Condition: Two or more required ADV lines inoperable ADVs is not inoperable a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Page 24

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification LCO Requirements and Condition Condition on Use 3.3.6.C LCO: [Four] channels of Loss of Voltage Function Licensee must justify (analog) and [four] channels of Degraded Voltage Function that more than two auto-initiation instrumentation per DG shall be channels per bus OPERABLE. inoperable is not a Condition: One or more Functions with more than condition in which all two channels inoperable. required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.4.9.B LCO: The pressurizer shall be OPERABLE Pressurizer is typically Condition: One [required] group of pressurizer not modeled in the heaters inoperable. PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.5.2.D LCO: Two ECCS trains shall be OPERABLE. Licensee must justify Condition: Less than 100% of the ECCS flow that one or more ECCS equivalent to a single OPERABLE train available. trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.

Page 25

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be Licensee must justify OPERABLE. Condition: One or more that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock not a condition in mechanism. which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6A LCO: Containment Spray and Cooling Systems Licensee must justify (Atmospheric and Dual) (Credit taken for iodine the ability to calculate a removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train including how the inoperable. system is modeled in Condition C: One containment cooling train the PRA, whether all inoperable. functions of the system Condition D: One containment spray and one are modeled, and, if a containment cooling train inoperable. surrogate is used, why Condition E: Two containment cooling trains that modeling is inoperable. conservative.

Page 26

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems Licensee must justify (Atmospheric and Dual) (Credit not taken for the ability to calculate a iodine removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train including how the inoperable. system is modeled in Condition B: One containment cooling train the PRA, whether all inoperable. functions of the system Condition C: Two containment spray trains are modeled, and, if a inoperable. surrogate is used, why Condition D: One containment spray train and one that modeling is containment cooling train inoperable. conservative.

Condition E: Two containment cooling trains inoperable.

Page 27

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 Licensee must justify shall be OPERABLE. that one or more Condition: One or more required SRMs inoperable SRMs is not inoperable in MODE 2 with intermediate range a condition in which all monitors (IRMs) on Range 2 or below required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.3.2.2.B LCO: [Three] channels of feedwater and main Licensee must justify turbine high water level trip instrumentation shall that two or more be OPERABLE. inoperable trip Condition: Two or more feedwater and main channels is not a turbine high water level trip channels inoperable. condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Page 28

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip Licensee must justify (EOC-RPT) Instrumentation that one or more Condition: One or more required channels inoperable EOC-RPT inoperable. channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Licensee must justify the ability to calculate a RICT given that EOC-RPT channels are not typically modeled in the PRA.

3.3.6.3.A LCO: Low-Low Set (LLS) Instrumentation Licensee must justify Condition: One LLS valve inoperable due to the ability to calculate a inoperable channel(s). RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Page 29

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE. that one or more Condition: One or more channels inoperable. channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.6.1.2.C LCO: The primary containment air lock shall be Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B. not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.

Page 30

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV, except reactor building-to- Licensee must justify suppression chamber vacuum breakers, shall be that PCIV leakage in OPERABLE. excess of the limits is Condition: One or more penetration flow paths not a condition in with one or more containment purge valves not which all required within purge valve leakage limits. trains or subsystems of a TS required system are inoperable.

Licensee must justify the ability to calculate a RICT for this inoperability.

3.6.1.7.D LCO: Each reactor building-to-suppression Licensee must justify chamber vacuum breaker shall be OPERABLE. that one or more Condition: Two or more lines with one or more inoperable vacuum reactor building -to-suppression chamber vacuum breakers on two or breakers inoperable for opening. more lines is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.7.7.A LCO: The Main Turbine Bypass System shall be Licensee must justify OPERABLE. the ability to calculate a OR RICT for the condition, The following limits are made applicable: including how the

[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR system is modeled in HEAT GENERATION RATE (APLHGR)," limits the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR]; and ] are modeled, and, if a

[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER surrogate is used, why RATIO (MCPR)," limits for an inoperable Main that modeling is Turbine Bypass System, as specified in the conservative.

[COLR]. ]

Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].

Page 31

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 Licensee must justify shall be OPERABLE. that one or more Condition: One or more required SRMs inoperable SRMs is not inoperable in MODE 2 with intermediate range a condition in which all monitors (IRMs) on Range 2 or below. required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Licensee must justify the ability to calculate a RICT given that SRMs are not typically modeled in the PRA.

Page 32

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip Licensee must justify (EOC-RPT) Instrumentation that one or more Condition: One or more required channels inoperable channels is inoperable. not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.3.6.5.A LCO: Relief and Low-Low Set (LLS) Licensee must justify Instrumentation the ability to calculate a Condition: One trip system inoperable. RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Page 33

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE. that one or more Condition: One or more channels inoperable. channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.

3.6.1.2.C LCO: The primary containment air lock shall be Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B. not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.

Page 34

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV shall be OPERABLE. Licensee must justify Condition: One or more penetration flow paths that PCIV leakage in with one or more containment purge valves not excess of the limits is within purge valve leakage limits. not a condition in which all required trains or subsystems of a TS required system are inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.1.7.A LCO: Residual Heat Removal (RHR) Containment Licensee must justify Spray System the ability to calculate a Condition: One RHR containment spray RICT for the condition, subsystem inoperable. including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.7.4.A LCO: Two [control room AC] subsystems shall be Licensee must justify OPERABLE. the ability to calculate a Condition: One [control room AC] subsystem RICT for the condition, inoperable. including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Page 35

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification LCO Requirements and Condition Condition on Use 3.7.6.A LCO: The Main Turbine Bypass System shall be Licensee must justify OPERABLE. the ability to calculate a OR RICT for the condition, The following limits are made applicable: including how the

[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR system is modeled in HEAT GENERATION RATE (APLHGR)," limits the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR] and ] are modeled, and, if a

[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER surrogate is used, why RATIO (MCPR)," limits for an inoperable Main that modeling is Turbine Bypass System, as specified in the conservative.

[COLR]. ]

Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].

Page 36

Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Note 1 Some Conditions are applicable when an unspecified number of subsystems or instrument channels are inoperable, typically written as "One or more" or "Two or more". These conditions currently apply when all subsystems or channels required to be operable to perform a function are inoperable, and application of a RICT in this situation is prohibited in the near-term TSTF-505 submittals.

To address this, it is recommended that the following modification to TSTF-505 be made to the Required Actions indicated in the Attachment 2 tables for Completion Times potentially applicable when all required subsystems or channels are inoperable.

The typical Completion Time is modified by TSTF-505 to state:

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (i.e., the existing Completion Time)

OR In accordance with the Risk Informed Completion Time Program It is recommended that the second Completion Time be modified with a Note, as shown below:

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (i.e., the existing Completion Time)

OR


NOTE-------------

Not applicable when

[all/four/both] required channels are inoperable.

In accordance with the Risk Informed Completion Time Program The bracketed number of channels will depend on the specification. This approach retains the existing requirements and limits the use of a RICT to conditions in which the function can still be performed.

The licensee must justify that the required function can still be performed absent an additional failure when a RICT is applied.

Alternatively, the licensee may modify the Condition to only apply when at least one subsystem or channel is operable, but this approach may require creating a new Condition or modifying an existing condition to retain the current requirements, or accepting a more restrictive requirement (such a LCO 3.0.3 entry).

Page 37

Attachment 3 TSTF-505 Model Application

PROPOSED MODEL APPLICATION FOR PLANT-SPECIFIC ADOPTION OF TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B" U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

SUBJECT:

[PLANT]

DOCKET NO. 50-[XXX]

LICENSE AMENDMENT REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT RISK INFORMED COMPLETION TIMES TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B."

REFERENCE:

Letter from the TSTF to U.S. NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'," dated DATE In accordance with the provisions of Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), [LICENSEE] is submitting a request for an amendment to the Technical Specifications (TS) for [PLANT.]

The proposed amendment would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the [DATE] letter from the TSTF to the NRC (Reference). The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399).

  • Attachment 1 provides a description and assessment of the proposed change, the requested confirmation of applicability, and plant-specific verifications.
  • Attachment 2 provides the existing TS pages marked up to show the proposed changes.
  • Attachment 3 provides revised (clean) TS pages.
  • Attachment 4 provides existing TS Bases pages marked up to show the proposed changes.

[LICENSEE] requests approval of the proposed license amendment by [DATE], with the amendment being implemented [BY DATE OR WITHIN X DAYS].

Page In accordance with 10 CFR 50.91(a)(1), "Notice for Public Comment," the analysis about the issue of no significant hazards consideration using the standards in 10 CFR 50.92 is being provided to the Commission.

In accordance with 10 CFR 50.91(b)(1), "Notice for Public Comment; State Consultation," a copy of this application, with attachments, is being provided to the designated [STATE] Official.

I declare [or certify, verify, state] under penalty of perjury that the foregoing is true and correct.

Executed on [date][Signature]

If you should have any questions regarding this submittal, please contact [NAME, TELEPHONE NUMBER].

Sincerely,

[Name, Title]

Attachments: 1. Description and Assessment

2. Proposed Technical Specification Changes (Mark-Up)
3. Revised Technical Specification Pages
4. Proposed Technical Specification Bases Changes (Mark-Up)

Enclosures:

1. List of Revised Required Actions to Corresponding PRA Functions
2. Information Supporting Consistency with Regulatory Guide 1.200, Revision 2.
3. Information Supporting Technical Adequacy of PRA Models Without PRA Standards Endorsed by Regulatory Guide 1.200, Revision 2.
4. Information Supporting Justification of Excluding Sources of Risk Not Addressed by the PRA Models.
5. Baseline CDF and LERF.
6. Justification of Application Of At-Power PRA Models to Shutdown Modes.
7. PRA Model Update Process.
8. Attributes of the CRMP Model.
9. Key Assumptions and Sources of Uncertainty.
10. Program Implementation
11. Monitoring Program
12. Risk Management Action Examples cc: NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact Page ATTACHMENT 1 DESCRIPTION AND ASSESSMENT OF THE PROPOSED CHANGE License Amendment Request for Adoption of TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b"

1.0 DESCRIPTION

The proposed amendment would modify the Technical Specification (TS) requirements related to Completion Times (CTs) for Required Actions to provide the option to calculate a longer, risk-informed CT (RICT). A new program, the Risk-Informed Completion Time Program, is added to TS Section 5 Administrative Controls.

The methodology for using the RICT Program is described in NEI 06-09-A, "Risk-Informed Technical Specifications Initiative 4b, Risk-Managed Technical Specifications (RMTS)

Guidelines," Revision 0, which was approved by the NRC on May 17, 2007. Adherence to NEI 06-09-A is required by the RICT Program.

The proposed amendment is consistent with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the TSTF's [DATE] letter to the NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'." However, only those Required Actions described in Enclosure 1 are proposed to be changed, [which does not include all of the modified Required Actions in TSTF-505 and which includes some plant-specific Required Actions not included in TSTF-505].

2.0 ASSESSMENT 2.1 Applicability of Published Safety Evaluation

[LICENSEE] has reviewed the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. This review included a review of the NRC staffs evaluation, as well as the supporting information provided to support TSTF-505 and the safety evaluation for NEI 06-09, as well as the TSTF's [DATE] letter on TSTF-505. [As described in the subsequent paragraphs,][LICENSEE] has concluded that the technical basis presented in the TSTF-505 proposal, the associated model safety evaluation prepared by the NRC staff, as modified by the TSTF letter on TSTF-505 are applicable to [PLANT, UNIT NOS.] and support incorporation of this amendment in the [PLANT] TS. ]

2.2 Verifications and Regulatory Commitments In accordance with Section 4.0, Limitations and Conditions, of the safety evaluation for NEI 06-09-A, the following is provided:

1. Enclosure 1 identifies each of the TS Required Actions to which the RICT Program will apply, with a comparison of the TS functions to the functions modeled in the probabilistic risk assessment (PRA) of the structures, systems and components (SSCs) subject to those actions.
2. Enclosure 2 provides a discussion of the results of peer reviews and self-assessments conducted for the plant-specific PRA models which support the RICT Program, as required by Regulatory Guide (RG) 1.200 Section 4.2.
3. [Enclosure 3 provides a description of all PRA models used to support the RICT Program for which Nuclear Regulatory Commission endorsed standards are not available.]

[Enclosure 3 is not applicable since each PRA model used for the RICT Program is addressed using a standard endorsed by the Nuclear Regulatory Commission.]

4. Enclosure 4 provides appropriate justification for excluding sources of risk not addressed by the PRA models.
5. Enclosure 5 provides the plant-specific baseline CDF and LERF to confirm that the potential risk increases allowed under the RICT Program are acceptable.
6. [Enclosure 6 provides appropriate plant-specific justification for using at power PRA models in shutdown modes to which the RICT Program applies (modes 3 [and 4]).]

[Enclosure 6 is not applicable since the RICT Program is not being applied to shutdown modes.]

7. Enclosure 7 provides a discussion of the licensees programs and procedures that assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant.
8. Enclosure 8 provides a description of how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP
9. Enclosure 9 provides a discussion of how the key assumptions and sources of uncertainty in the PRA models were identified, and how their impact on the RICT Program was assessed and dispositioned.
10. Enclosure 10 provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation, including risk management action (RMA) implementation.

Page

11. Enclosure 11 provides a description of the implementation and monitoring program as described in NEI 06-09, Section 2.3.2, Step 7.
12. Enclosure 12 provides a description of the process to identify and provide RMAs.

2.3 Optional Changes and Variations

[LICENSEE is not proposing any changes, variations, or deviations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE], except as described in the TSTF letter dated [DATE].] [LICENSEE is proposing the following changes or variations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE].

These options were recognized as acceptable changes or variations in TSTF-505 and the NRC staff's model safety evaluation.]

{NOTE: If a change or variation is not identified in TSTF-505, the NRC staff's model safety evaluation, or NEI 06-09 then provide the description and justification.}

[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-505 was based. Specifically, [describe differences between the plant-specific TS numbering and/or titles (including Required Actions and programs) and the TSTF-505 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-505 to the [PLANT] TS.]

3.0 REGULATORY SAFETY ANALYSIS 3.1 No Significant Hazards Consideration Determination

[LICENSEE] has evaluated the proposed change to the TS using the criteria in 10 CFR 50.92 and has determined that the proposed change does not involve a significant hazards consideration.

[PLANT, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) and plant-specific technical specifications (TS), to modify the TS requirements related to Completion Times for Required Actions to provide the option to calculate a longer, risk-informed Completion Time. The allowance is described in a new program in Chapter 5, "Administrative Controls," entitled the "Risk-Informed Completion Time Program."

As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazards consideration is presented below:

1. Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Page Response: No.

The proposed change permits the extension of Completion Times provided the associated risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change does not involve a significant increase in the probability of an accident previously evaluated because the change involves no change to the plant or its modes of operation. The proposed change does not increase the consequences of an accident because the design-basis mitigation function of the affected systems is not changed and the consequences of an accident during the extended Completion Time are no different from those during the existing Completion Time.

Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No.

The proposed change does not change the design, configuration, or method of operation of the plant. The proposed change does not involve a physical alteration of the plant (no new or different kind of equipment will be installed).

Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.

3. Does the proposed change involve a significant reduction in a margin of safety?

Response: No.

The proposed change permit the extension of Completion Times provided risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change implements a risk-informed configuration management program to assure that adequate margins of safety are maintained. Application of these new specifications and the configuration management program considers cumulative effects of multiple systems or components being out of service and does so more effectively than the current TS.

Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Page Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

4.0 ENVIRONMENTAL CONSIDERATION

[LICENSEE] has reviewed the environmental evaluation included in the model safety evaluation published on [DATE] ([ ] FR [ ]) as part of the Notice of Availability. [LICENSEE] has concluded that the NRC staff findings presented in that evaluation are applicable to [PLANT, NO.].

The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

Page ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)

{provided by the licensee}

ATTACHMENT 3 REVISED TECHNICAL SPECIFICATION PAGES

{provided by the licensee}

ATTACHMENT 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES CHANGES (MARK-UP) PAGES

{provided by the licensee}

ENCLOSURE 1 LIST OF REVISED REQUIRED ACTIONS TO CORRESPONDING PRA FUNCTIONS

{NOTE: This enclosure provides confirmation that the PRA models include the necessary scope of structures, systems, and components (SSCs) and their functions to address each proposed application of the RICT Program to the TS Required Actions.

TS conditions with insufficient TS operable equipment to meet the specified safety function of the system, are not to be included in the application.

List each TS Required Action to which the RICT Program may be applied and, for each Required Action, describe the following:

  • The TS Required Action;
  • The corresponding SSC;
  • Each design basis function of the SSC;
  • How each design basis function is modeled in the PRA. If one of the design basis functions of an SSC or the SSC is not modeled in the PRA, describe any proposed surrogates and why the proposed surrogate adequately captures the configuration risk; and
  • The success criteria used in the PRA model compared to the licensing basis criteria. The success criteria should include both train-level and component/parameter level.

Note that the above description should be at the level of the TS condition/TS Required Action (not at the LCO level only). If the TS condition/ TS Required action covers multiple SSCs or multiple design basis functions, such as in the case ESFAS Instrumentation or Containment Sprays, describe each one individually.

The enclosure should also include clear definitions of any used terms, such as train, division, loop, "subsystem," etc.

The enclosure should provide a detailed system description of TS 3.8, "Electrical Power Systems," Required Actions if the loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs.) Also, provide a description in Enclosure 12 of representative RMAs for non-uniform trains to demonstrate that the systems safety function is maintained with either train or subsystem operable.}

ENCLOSURE 2 INFORMATION SUPPORTING CONSISTENCY WITH REGULATORY GUIDE 1.200, REVISION 2

{NOTE: This enclosure provides information supporting the licensee evaluation of the technical adequacy of the PRA models supporting the RICT Program based on peer reviews and self-assessments against the relevant PRA standards as endorsed in the current applicable revision of RG 1.200, including consideration of staff clarifications of the standards.

Per NEI 06-09 Rev. 0, capability category II of the standards is applicable; therefore, the licensee identifies those parts of the PRAs that conform to capability categories lower than II, and provides a disposition for the RICT Program. Consistent with RG 1.200 Section 4.2, the licensee identifies and provides a discussion of the resolution of any findings and observations from the peer reviews or self-assessments.

The licensee assessment must also address the clarifications and qualifications found in RG 1.200, either by a separate discussion provided by the licensee, or by confirmation that the peer reviews or self-assessments included consideration of the clarifications and qualifications of the current applicable RG 1.200 revision.

Licensees are strongly encouraged to apply the guidance in Appendix X, "Close out of Facts and Observations," of NEI 05-04, "Process for Performing Internal Events PRA Peer Reviews Using the ASME/ANS PRA Standard, Rev 3, November 2009," NEI 07-12, "Fire Probabilistic Risk Assessment Peer Review Process Guidelines, Rev 1, June 2010," and NEI 12-13, "External Hazards PRA Peer Review Process Guidelines, Rev 0, August 2012," to close PRA peer review findings, as this will make more efficient use of the NRC and industry resources needed to develop and review of the application. }

ENCLOSURE 3 INFORMATION SUPPORTING TECHNICAL ADEQUACY OF PRA MODELS WITHOUT PRA STANDARDS ENDORSED BY REGULATORY GUIDE 1.200, REVISION 2

{NOTE: This enclosure provides information supporting the licensee evaluation of the PRA models supporting the RICT Program for which the relevant PRA standards are not yet endorsed in the current applicable revision of RG 1.200.

RG 1.200 Rev. 2 endorses standards for internal and external events including internal floods and fires, seismic events, and other external hazards for full power conditions.

This scope includes the relevant hazard groups applicable to a RICT Program unless the program is to apply to lower modes of operation. In this case, shutdown and transition risk PRA models may apply but are not be covered by an endorsed standard.

If applicable, the licensee should provide a detailed description of these PRA models and the basis for its determination of their technical adequacy to support the RICT Program.}

ENCLOSURE 4 INFORMATION SUPPORTING JUSTIFICATION OF EXCLUDING SOURCES OF RISK NOT ADDRESSED BY THE PRA MODELS

{NOTE: This enclosure identifies and provides a justification for excluding sources of risk which are not in the scope of the PRA models applied to the RICT Program.

Exclusion of risk sources determined to be insignificant to the calculation of configuration specific risk, or the use of conservative or bounding analyses for the calculation of RICTs in lieu of realistic PRA models, are described. A qualitative treatment may be sufficient if the licensee demonstrates that those risk contributions would not affect decisions in a RICT Program. The use of conservative bounding calculations in a RICT Program may also be acceptable. However, when the risk associated with a particular hazard group would affect decisions, it is the Commissions policy that risk be assessed using a PRA that meets the staff-endorsed PRA standard.

External hazards screened out from inclusion in RICT calculations should be clearly identified as such, and should be done in a manner consistent with Part 6 of the ASME ANS PRA Standard. The justification should address baseline and configuration-specific considerations.

For external hazards that are not screened out from inclusion in RICT calculations, the licensee may propose a bounding approach to address the hazard. If the bounding approach involves assuming a uniform increase in baseline risk to address the hazard, the licensee will need to address potential RICT-specific impacts by doing one of the following:

  • Demonstrate in the LAR that this approach is bounding for all TS actions included in the LAR, or
  • Establish a procedure to evaluate the validity of the bounding approach when calculating an RICT that is not demonstrated to be bounded in the LAR, or
  • For RICTs not demonstrated to be bounded in the LAR, establish a procedure to qualitatively evaluate the impact of the specific external hazard for each RICT when calculated and apply risk management actions as appropriate. }

ENCLOSURE 5 BASELINE CDF AND LERF

{NOTE: This enclosure provides the plant-specific total CDF and total LERF to confirm that these are less than 10-4/year and 10-5/year, respectively. This assures that the potential risk increases allowed under the RICT Program are consistent with RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.

The licensee should provide the totals and the contributions from each hazard group (internal events, fires, floods, seismic, other external). }

ENCLOSURE 6 JUSTIFICATION OF APPLICATION OF AT-POWER PRA MODELS TO SHUTDOWN MODES

{NOTE: This enclosure provides a justification for the use of existing PRA models during shutdown conditions if the RICT Program is applicable in these shutdown conditions.

The at-power PRA models may potentially be applied to lower modes of operation (hot standby for PWRs, and hot shutdown for PWRs and BWRs) for some Required Actions.

If the licensee is not proposing to use the RICT Program in these modes, then this information is not required and this Enclosure should be marked "Not applicable."

Otherwise, the licensee provides a detailed justification for those Required Actions proposed to apply the RICT Program in lower modes of operation using the at-power PRA models.}

ENCLOSURE 7 PRA MODEL UPDATE PROCESS

{NOTE: This enclosure describes how the PRA models used in the calculation of completion times is maintained consistent with the as-built, as-operated plant.

The licensee provides a discussion of its programs and procedures to assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant. This should include a discussion of the timing of significant PRA model changes as described in NEI 06-09, Section 2.3.4, Step 7.}

ENCLOSURE 8 ATTRIBUTES OF THE CRMP MODEL

{NOTE: This enclosure describes how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP.

The licensee provides a description of the PRA models and CRMP used to support the RICT Program. The following specific attributes must also be addressed:

  • The baseline PRA models assess the average annual risk. However, some risk is not consistent throughout the year or the operating cycle, and the PRA models used for the CRMP need to properly assess the change in risk for the existing plant conditions. For example, success criteria may be different at core beginning of life compared to end of life, or at different times of the year for room cooling systems. The licensee describes these issues and how they are addressed in the CRMP.
  • The baseline PRA models may assume some configurations are not allowable, but these assumptions may not be applicable to a CRMP. The licensee describes these issues and how they are addressed in the CRMP.
  • The scope of SSCs within the CRMP is provided, along with confirmation that the CRMP tools can be readily applied for each TS Required Action within the scope of the Risk-Informed Completion Time Program. The licensee should also identify and justify SSCs that are not included in the CRMP that could provide accident mitigation functions.
  • The licensee describes how consistency of calculated results from the baseline PRA model and the CRMP are verified to assure the CRMP PRA models are consistent with the baseline model and updated when the baseline PRA model is updated.
  • The licensee describes the quality requirements applied to the CRMP PRA models.
  • The licensee describes the training and qualification programs applicable to personnel responsible for development and use of the CRMP.}

ENCLOSURE 9 KEY ASSUMPTIONS AND SOURCES OF UNCERTAINTY

{NOTE: This enclosure describes the key assumptions and sources of uncertainty in the PRA models, and how their impact on the RICT Program was assessed and dispositioned. Sensitivity analyses for various plant configuration cases under different assumptions should be provided to justify conclusions.}

ENCLOSURE 10 PROGRAM IMPLEMENTATION

{NOTE: This enclosure provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation including training of plant personnel, and specifically discusses the decision process for risk management action (RMA) implementation during extended CTs.}

ENCLOSURE 11 MONITORING PROGRAM

{NOTE: This enclosure describes the monitoring program for cumulative risk impacts as described in NEI 06-09, Revision 0, Section 2.3.2, Step 7. This should include a description of how the calculations are made and what actions and thresholds are applied when corrective measures are necessary due to excessive risk increases.}

ENCLOSURE 12 RISK MANAGEMENT ACTION EXAMPLES

{NOTE: This enclosure describes the process for identification of RMAs applicable during extended CTs, and provides examples of RMAs.

Provide example RMAs for TS 3.8 Required Actions. These should be representative examples, such as a long and short RICTs. See the Plant Vogtle April 14, 2017 RAI response (ADAMS Accession No. ML17108A253) for an example.

If the TS-required electrical power loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs,) provide a description of representative RMAs for non-uniform trains to ensure that the systems safety function is maintained with either train or subsystem inoperable.}