MONTHYEARML24289A0342024-08-0808 August 2024 Discussion of NRC Staff Comments on Draft TSTF-585, Revision 3, Revise LCO 3.0.3 to Require Managing Risk ML24129A0662024-05-0808 May 2024 5_8_24 Meeting Handouts - History of Traveler Adoption ML24129A0652024-05-0808 May 2024 5_8_24 Meeting Handouts - Active Traveler Summary Report and Priorities ML24129A0672024-05-0808 May 2024 5_8_24 Meeting Handouts - Proposed Change to the PWR ECCS Mode 4 Requirements ML24044A1402024-02-0808 February 2024 TSTF Handout for 02/08/2024 Quarterly Meeting ML24038A3492024-02-0707 February 2024 NRC Comments for Pre-submittal Meeting TSTF-600, Revise the Reactor Coolant System (RCS) Pressure Isolation Valve (PIV) Leakage Testing Frequency ML23257A1582023-09-18018 September 2023 NRC Staff Feedback Draft TSTF-601, Extend Shield Building Completion Time After Refueling for Pre-submittal Meeting on 9/18/23 ML23033A3842023-02-0202 February 2023 February 9, 2023, Meeting Handout: NRC Staff Comments on TSTF-576 Revision 2 (Draft), SRV Requirements ML22298A2162022-10-25025 October 2022 TSTF Meeting Handout TSTF-585 and the Maintenance Rule ML22298A2172022-10-24024 October 2022 TSTF Meeting Handout Strategic Improvements to TS and TS-Related Processes ML22298A2152022-10-20020 October 2022 TSTF Meeting Handout Natural Phenomena and Operability Workshop ML22056A2932022-02-24024 February 2022 2/24/2022 Meeting Handout - Active Traveler Summary Report ML22056A2942022-02-24024 February 2022 2/24/2022 Meeting Handout - TSTF 2021 in Review ML22038A6032022-02-10010 February 2022 Summary of January 10, 2022, Meeting with the Technical Specifications Task Force Draft Traveler TSTF-589 Eliminate Automatic Diesel Generator Start During Shutdown ML22013B1422022-02-0101 February 2022 TSTF-576 Workshop February 2022 - NRC Presentation ML21217A0692021-08-0505 August 2021 Meeting Handout - Active Traveler Summary Report ML21158A0902021-06-0707 June 2021 Technical Specifications Branch Feedback/Comments on Draft TSTF-585, Revise LCO 3.0.3 ML21126A0712021-05-0606 May 2021 5/6/2021 Meeting Handout - Interaction of Technical Specification Surveillances and 10 CFR 50.69 ML21126A0732021-05-0606 May 2021 5/6/2021 Meeting Handout - Active Traveler Summary Report ML21126A0722021-05-0606 May 2021 5/6/2021 Meeting Handout - Expected TSTF-577 Submittals ML21029A3082021-01-29029 January 2021 Trio Public Meeting Slides (Thursday, February 4, 2021) ML21007A1112021-01-0707 January 2021 TSTF-577, NRC Staff Slides from Public Meeting on 1_7_2021 ML20329A3412020-11-24024 November 2020 TSTF-576 Example Scenarios for 12/7/2020 Meeting ML20287A2632020-10-13013 October 2020 TSTF Presentation Proposal to Improve the Core Operating Limits Report (COLR) ML20125A0922020-05-0404 May 2020 May 4, 2020, Pre-submittal Meeting Handout Staff Comments Draft TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML20065J9322020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item VA - Proposal to Revise LCO 3.0.3 ML20069F2882020-03-0505 March 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Iia - 2019 in Review ML20065J9902020-03-0505 March 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Iiib - Generic RAIs for LARs to Adopt TSTF-505 Rict ML20065J9332020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item IV - Active Traveler Summary Report and Priorities ML20065J9342020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item Iia - 2019 in Review ML20069F2852020-01-0101 January 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Via - TSTF Charter Statement 2020 ML19267A1592019-09-24024 September 2019 TSTF Handout for October 16, 2019, Meeting: TSTF-493 Questions ML19259A2082019-09-12012 September 2019 TSTF Presentation from TSTF-576, S/Rv Requirements Pre-submittal Meeting on September 12, 2019 TSTF-19-07, TSTF Handout for October 16, 2019, Meeting: Elimination of Commitment to Adopt TSTF-4932019-06-18018 June 2019 TSTF Handout for October 16, 2019, Meeting: Elimination of Commitment to Adopt TSTF-493 ML19056A4232019-02-21021 February 2019 Meeting Attendees 02/21/2019 ML19056A4242019-02-21021 February 2019 TSTF-568 Proposed Path Forward from 2/21/2019 Meeting ML19056A4262019-02-21021 February 2019 Rewording of TSTF Revision to TSTF-541, Add Exceptions to Surveillance Requirements When the Safety Function Is Being Performed ML18312A3662018-11-0808 November 2018 Handout from 11/8/2018 TSTF Meeting for Agenda Items V.A and V.B Active Traveler Summary Report and Traveler Review Priorities ML18312A3672018-11-0808 November 2018 Handout from 11/08/2018 TSTF Meeting for Agenda Item Ii.B.C November 2018 Traveler Review Schedule Changes ML18221A5712018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 4.A TSTF Response TSTF-51 -286 -471 ML18221A5722018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 3.A - DNP LAR Analysis ML18221A5742018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A.6 - TSTF-565R1 ML18221A5752018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A Active Traveler Summary Report ML18221A5772018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 4.C - TSTF-542 Adoption Status ML18221A5812018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A.6 NRC Feedback Re TSTF-568 Evaluation of STS 3.6.3.2 ML18221A5732018-08-0606 August 2018 August 9, 2018, Meeting Agenda Item 7.A - Is the Table of Contents Part of the Technical Specifications? ML18142B0372018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 2.A - TSTF-563 Coordinated Submittal Pilot ML18142B0352018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 4.B - TSTF-547 Issue ML18142B0312018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 8.A - T Traveler Candidates ML18142B0332018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 8.A - Approved Unincorporated Travelers 2024-08-08
[Table view] |
Text
Active Travelers Summary Report (See Topics Report for More Information)
TSTF Number Applicability Description TSTF-554, Rev. 1 All Revise Reactor Coolant Leakage Requirements Topic Number: 1391 Draft Provided to NRC: Not applicabl Date of Presubmittal Meeting: Not applicable Originally Submitted: 5/7/2019 Age: 10 Months PWROG PA: LSC-1623 PWROG RISD: RS-2018-001 Originally Scheduled for Approval: 12/18/2020 Number of Times Approval Date has been Rescheduled: 0 Review Hour Estimate N/A NRC Review Fees Waived Actions and Schedule Responsibility Date Revision 0 and fee wavier request submitted on 5/7/2019. NRC 7/9/2019 7/9/2019 - NRC approved fee waiver.
NRC provided an acceptance and schedule letter on August 20, 2019. NRC 9/6/2019 RAIs by 11/6/2019 Draft SE by 7/17/2020 Final SE by 12/18/2020 NRC provided RAIs and revised schedule on November 26, 2019. TSTF to TSTF 2/24/2020 respond.
Revised schedule:
Issue Draft SE - July 17, 2020 Issue Final SE - December 18, 2020.
TSTF responded to RAI and provided a revision of TSTF-554 on NRC 7/17/2020 1/16/2020. NRC to provide the draft Safety Evaluation.
TSTF-576, Rev. 0 BWROG Revise Safety/Relief Valve Requirements Topic Number: 1465 Draft Provided to NRC: 8/26/2019 Date of Presubmittal Meeting: 12/2/2019 Originally Submitted: 12/13/2019 Age: 3 Months PWROG PA: N/A PWROG RISD: N/A Originally Scheduled for Approval: 6/5/2021 Number of Times Approval Date has been Rescheduled: 0 Review Hour Estimate 576 No NRC Review Fees Received Actions and Schedule Responsibility Date TSTF submitted TSTF-576 to NRC for review on December 13, 2019. TSTF 12/13/2019 NRC provided the acceptance and schedule letter on February 13, 2020. NRC 2/14/2020 Issue RAIs: 5/11/2020 Issue Draft SE: 2/18/2021 Issue Final SE: 6/5/2021 NRC to provide RAIs. NRC 5/11/2020 Page 1 of 2 02-Mar-20
Active Travelers Summary Report (See Topics Report for More Information)
TSTF Number Applicability Description TSTF-577, Rev. 0 PWROG Performance Based Frequencies for Steam Generator Tube Inspections Topic Number: 1463 Draft Provided to NRC: 9/10/2019 Date of Presubmittal Meeting: 10/16/2019 Originally Submitted: Age: N/A PWROG PA: PA-LSC-1649 PWROG RISD: RS-2018-023 Originally Scheduled for Approval: Not applicable Number of Times Approval Date has been Rescheduled: 0 Review Hour Estimate 0 No NRC Review Fees Received Actions and Schedule Responsibility Date The EPRI SGMP and NRC met on Feburary 24, 2020 to discuss the NRC 3/9/2020 justification for a revised traveler. NRC to provide recommended 180-day EPRI SGMP report items and EPRI to provide summary of technical justification within 2 weeks to support traveler development.
TSTF-582, Rev. 0 BWROG RPV WIC Enhancements Topic Number: 1480 Draft Provided to NRC: 7/3/2019 Date of Presubmittal Meeting: 7/30/2019 Originally Submitted: 8/28/2019 Age: 7 Months PWROG PA: Unassigned PWROG RISD: N/A Originally Scheduled for Approval: 8/28/2020 Number of Times Approval Date has been Rescheduled: 0 Review Hour Estimate 570 NRC Review Fees To Date: $137,056.50 (BWROG)
Actions and Schedule Responsibility Date NRC provided RAIs on December 17, 2019. TSTF 2/17/2020 2/12/2020 - RAI response submitted.
NRC to provide draft Safety Evaluations for comment. NRC 5/15/2020 Active Travelers: 4 Page 2 of 2 02-Mar-20
Traveler Relative Priorities Traveler Priority TSTF-554, Rev. 0, "Revise Reactor Coolant Leakage Requirements" Low TSTF-576, Rev. 0, "Revise Safety/Relief Valve Requirements" High TSTF-577, Rev. 0, "Performance Based Frequencies for Steam Generator Tube High Inspections" TSTF-582, Rev. 0, "RPV WIC Enhancements" High Page 1 EXCEL Services Corporation