TSTF 2021 in Review
- 2021 marks the 19th year (2003) of the TSTF as a jointly sponsored Owners Group activity (27 years as an organization in 1995)
- One change in TSTF membership: David Gullott (Constellation) replaced Dwi Murray (Constellation)
- Travelers:
o Two travelers were approved:
TSTF-577, Rev. 1, Rev. 0, "Revised Frequencies for Steam Generator Tube Inspections" (PWRs) 416/2021.
- 673 review hours.
- Approved or submitted by 16 sites to date.
TSTF-580, Rev. 1, "Provide Exception from Entering Mode 4 With No Operable RHR Shutdown Cooling" (BWRs) 7/11/2021.
- 267 review hours.
o Five new travelers were submitted:
TSTF-584, Rev. 0 (Draft), Eliminate Automatic RWCU System Isolation on SLC Initiation," (BWR) 9/24/2021 TSTF-585, Rev. 1 (Draft), "Provide an Alternative to the LCO 3.0.3 One-Hour Preparation Time," (All) 11/30/2021 TSTF-588, Rev. 0 (Draft), "Remove List of COLR Methods," (All) 4/26/2021 TSTF-589, Rev. 0, "Eliminate Automatic Diesel Generator Start During Shutdown," (PWR) 10/26/21 (submitted 2/3/2022)
TSTF-591, Rev. 0 (Draft), "Revise Risk Informed Completion Time (RICT)
Program," (All) 11/11/2021 o One revised traveler was submitted:
TSTF-576, Rev. 1, "Revise Safety/Relief Valve Requirements," (BWR) 6/23/21 o The NRC expended 1,075 fee-billable hours reviewing travelers in 2021.
- The TSTF exchanged 11 letters with the NRC:
o 5 from the NRC (excludes meeting notices and summaries) o 6 from the TSTF
TSTF 2021 in Review o This is down from 20 letters in 2020 illustrating how more business is being conducted by email and teleconferences.
- The TSTF held 30 teleconferences with NRC.
- Other TSTF/NRC Activities:
o The NRC published Revision 5 of the Standard Technical Specifications (NUREG-1430 through NUREG-1434), completing an 18-month cooperative project between the TSTF and the NRC to update the STS.
o The TSTF published TSTF-GG-21-01, "Technical Requirements Manual and Operational References (TRM) Format and Content Guideline," (April 2021).
- License Amendments to Adopt Travelers There were 90 license amendments to adopt TSTF travelers submitted in 2021.
There were 88 license amendments to adopt TSTF travelers approved in 2021.
0 20 40 60 80 100 120 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 Approved Amendments to Adopt Travelers by Year 2010-2021