{{#Wiki_filter:EOP: P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV'PAGE 1 of 11 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC, REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY: 94iOi80209 940930 PDR ADDCK 05000244 P 4I EOP: P-PRZR.l TITLE: ABNORMAL PRESSURIZER PRESSURE REV 7 PAGE 2 of 11 A.PURPOSE-This procedure provides the actions necessary to mitigate the consequences of abnormal PRZR pressure.B.ENTRY CONDITIONS/SYMPTOMS l.ENTRY CONDITIONS
{{#Wiki_filter:EOP:           TITLE:
-This procedure is entered from: a.AP-CVCS.1, CVCS LEAK, or b~AP FW 1 i PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER, or c.AP-IA.1, LOSS OF INSTRUMENT AIR, or d.AP-RCC.1, CONTINUOUS CONTROL ROD WITHDRAWAL OR INSERTION, or e.AP-RCS.1, REACTOR COOLANT LEAK, or f AP TURB~1 g TURBINE TRI P WITHOUT RX TRI P REQUIRED g or g.AP-TURB.2, TURBINE LOAD REJECTION, when PRZR pressure can NOT be controlled.
REV' P-PRZR.1             ABNORMAL PRESSURIZER PRESSURE PAGE 1 of 11 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC, REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY   1.0 REVIEWED BY:
2.SYMPTOMS-The symptoms of ABNORMAL PRZR PRESSURE are;a.Annunciator F-19, PRZR PORV OUTLET HI TEMP 145'F, lit, or b.Annunciator F-18, PRZR SAFETY VLV OUTLET HI TEMP 145'F, lit, or c.Annunciator AA-13, PRESSURIZER SAFETY VALVE POSITION, lit, or d.Annunciator F-l, PRT LIQUID HI TEMP 220'F, lit, or e.Annunciator F-9, PRT HI PRESS 5 PSI, lit, or f.Annunciator F-17, PRT LEVEL 60.8 4 84.5, lit, or g.Annunciator F-2, PRESSURIZER HI PRESS 2310 PSI, lit, or h.Annunciator F-10, PRESSURIZER LO PRESS 2185 PSI, lit, or i.Annunciator F-6, PRESSURIZER HEATER BREAKER TRIP, lit.j.Annunciator F-26, PRESSURIZER HI PRESS CHANNEL ALERT 2377 PSI.
94iOi80209 940930 PDR   ADDCK 05000244 P
EOP: P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV: 7 PAGE 3 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED*****************
 
4**%**%*****************
4I EOP:         TITLE:
CAUTION IF, AT ANY TIME DURING THIS PROCEDURE, A REACTOR TRIP OR SI OCCURS, E-O, REACTOR TRIP OR SAFETY INJECTION, SHALL BE PERFORMED.
REV    7 P-PRZR.l               ABNORMAL PRESSURIZER     PRESSURE PAGE 2   of 11 A. PURPOSE     This procedure provides the actions necessary to mitigate the consequences       of abnormal PRZR pressure.
**xx***xxx*x*x*xx%%'ex xxk*xxxxx**%x**x%'*xx NOTE: Actual PRZR pressure should be verified by more than 1 indicator.
B. ENTRY CONDITIONS/SYMPTOMS
1 Check PRZR Pressure: o All 4 narrow range channels APPROXIMATELY EQUAL o All 4 narrow range channels TRENDING TOGETHER IF one pressure channel deviates significantly from the other 3, THEN perform the following:
: l. ENTRY CONDITIONS This       procedure   is entered from:
a.IF the controlling PRZR pressure channel has failed, THEN place controller, 431K, in MANUAL and adjust output to restore PRZR pressure.b.Refer to ER-INST.l, REACTOR PROTECTION BISTABLE DEFEAT AFTER INSTRUMENTATION LOOP FAILURE.2 Check Reactor Power-STABLE IF the abnormal, PRZR pressure is a result of a power transient, THEN evaluate conditions and go to the appropriate plant procedure.
: a. AP-CVCS.1,   CVCS LEAK,   or b ~   AP FW 1 i PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER, or
3 Check PRZR Pressure: a.Pressure-LESS THAN 2235 PSIG b.Pressure-GREATER THAN 2000 PSIG a.Go to Step 12 b.IF pressure decreasing uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP OR SAFETY INJECTION.
: c. AP-IA.1,   LOSS OF INSTRUMENT     AIR, or
EOP: P-PRZR.1 TITLE ABNORMAL PRESSURIZER PRESSURE REV: 7 PAGE 4 of ll STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**x***x x x~x**x x x x 4*x x x x x w~*x x x x**x*******
: d. AP-RCC.1, CONTINUOUS CONTROL       ROD WITHDRAWAL OR INSERTION,   or
CAUTION OBSERVE D/G LOADING LIMITS OF 2300 KW FOR 1/2 HOUR, 2250 KW FOR 2 HOURS, AND 1950 KW FOR CONTINUOUS SERVICE.*******xx*xx*xxxxxxxxxx>x****xx**xx**x***
: e. AP-RCS.1, REACTOR COOLANT LEAK,         or f     AP TURB ~ 1 g TURBINE TRI P WITHOUT   RX TRI P REQUIRED g   or
4 Check PRZR Heater Status: a.PRZR heater control group BREAKER CLOSED a.Place PRZR heater control group switch to TRIP to reset, then place switch to CLOSE and let return to AUTO.b.PRZR heater backup group-ON b.IF PRZR pressure less than 2220 psig, THEN energize PRZR backup heaters.IF PRZR backup heater breaker has tripped, THEN perform the following:
: g. AP-TURB.2, TURBINE LOAD REJECTION, when PRZR pressure can NOT be controlled.
1)Place the breaker switch to OFF to reset breaker.2)Place the breaker switch to ON to energize heaters.3)Verify load increase on Bus 16.
: 2. SYMPTOMS       The symptoms   of ABNORMAL PRZR PRESSURE     are;
1 EOP: P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV'PAGE 5 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 5 Verify Normal PRZR Spray Valve Controllers
: a. Annunciator F-19, or PRZR PORV OUTLET     HI TEMP 145'F,   lit,
-DEMAND AT 0~o Place controllers in MANUAL at 0%demand.IF valves can NOT be closed, THEN perform the following:
: b. Annunciator F-18,   PRZR SAFETY VLV OUTLET       HI TEMP   145'F, lit, or
a.Trip the reactor.b.Trip the associated RCP.c.Go to E-O, REACTOR TRIP OR SAFETY INJECTION.
: c. Annunciator   AA-13, PRESSURIZER SAFETY VALVE POSITION, lit, or
NOTE: With PRZR pressure controller 431K in manual, PORV-431C will not be operable in the automatic mode.6 Check PRZR Pressure Controller, 431K, Demand-LESS THAN 504 Place 431K in MANUAL and decrease output t:o energize PRZR heaters.
: d. Annunciator F-l,   PRT LIQUID HI TEMP 220'F,       lit, or
I ll 0 ts EOP: P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE REV: 7 PAGE 6 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Check PRZR PORVs: a.PORVs-CLOSED a.Manually close PORVs.IF any valve can NOT be closed, THEN manually close the associated block valve.~MOV-516 for PCV-430~MOV-515 for PCV-431C b.Annunciator F-19, PRZR PORV OUTLET HI TEMP 145'F EXTINGUISHED b.IF PORV leakage is indicated, THEN perform the following:
: e. Annunciator F-9,   PRT HI   PRESS 5 PSI, lit, or
1)Close PORV block valves one at a time AND check if pressure stabilizes.
: f. Annunciator F-17,     PRT LEVEL   60.8 4 84.5, lit, or
~MOV-515~MOV-516 c.Go to Step 9 2)IF a leaking PRZR PORV is identified, THEN restore any nonleaking PORV to operable AND go to Step 8.
: g. Annunciator F-2,   PRESSURIZER HI PRESS       2310 PSI,   lit, or
I EOP: P-PRZR.1 TITLE ABNORMAL PRESSURIZER PRESSURE REV: 7 PAGE 7 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 8 Attempt To Reseat Any Leaking PORV: a.Verify affected PORV block valve CLOSED a.Close the affected PORV block valve.b.Cycle the leaking PORV open then closed c.Open affected PORV block valve d.Verify leakage has stopped d.IF leakage continues, THEN perform the following:
: h. Annunciator   F-10, PRESSURIZER LO PRESS 2185 PSI, lit, or
1)Reclose leaking PORV block valve.e.Go to Step 11 2)Refer to Tech Spec section 3.1.1.4 for required actions.
: i. Annunciator   F-6, PRESSURIZER HEATER BREAKER TRIP, lit.
(~q I 4~'
: j. Annunciator F-26, 2377 PSI.
EOP: P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV 7 PAGE 8 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED**x**x*xx*x**xxx%xx%***x*x*****xx**x*****
PRESSURIZER    HI PRESS CHANNEL ALERT
CAUTION o IF PRZR PRESSURE IS TO BE REDUCED WHILE AT POWER, IT SHOULD BE DONE SLOWLY SINCE THE PRZR LOW PRESSURE TRIP IS RATE SENSITIVE.
 
o WHEN REDUCING PRZR PRESSURE, OT4T SETPOINT WILL DECREASE.******%**x'****%x*x x x*x***x******%'***x***
EOP:             TITLE:
9 Check PRZR Safety Valves: o Position indicator-LESS THAN 0.1 INCH.o Annunciator F-18, PRZR SAFETY VLV OUTLET HI TEMP 145'F EXTINGUISHED o Annunciator AA-13, PRESSURIZER SAFETY VALVE POSITION EXTINGUISHED IF safety valve leakage indicated, THEN perform the following to attempt to reseat the leaking valve: a.SLOWLY reduce PRZR pressure (remain above 2000 psig).b.IF symptoms indicate leakage has stopped, THEN restore pressure to normal.c.IF leakage recurs or can NOT be stopped, THEN perform the following:
REV: 7 P-PRZR.1                     ABNORMAL PRESSURIZER     PRESSURE PAGE 3   of 11 STEP       ACTION/EXPECTED RESPONSE               RESPONSE   NOT OBTAINED
1)Verify leakage within limits of Tech Spec section 3.1.5.2)Go to Step 17.10 Check AUX Spray'alve, AOV-296-CLOSED Manually close valve.IF valve can NOT be closed, THEN consider isolating letdown and closing cha'rging flow control valve, HCV-142.
  *****************                       4 **% **% ****************
I' EOP: P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV: 7 PAGE 9 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 11 Check PRZR Pressure Control Restored: a.Pressure-TRENDING TO 2235 PSIG b.Go to Step 17 a.IF pressure continues to decrease, THEN return to Step 1.12 Check PRZR Backup Heaters-OFF Verify PRZR backup heater switch in AUTO, AND ensure proper operation.
CAUTION IF, AT ANY TIME DURING THIS PROCEDURE, A REACTOR TRIP OR         SI   OCCURS,   E-O, REACTOR TRIP OR SAFETY INJECTION, SHALL BE PERFORMED.
NOTE: With PRZR pressure controller 431K in manual, PORV-431C will not be operable in the automatic mode.13 Check PRZR Pressure Controller, 431K, Demand-INCREASING Place 431K in MANUAL at 50%demand.NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.o The bT between the REGEN Hx charging outlet and the PRZR shall NOT exceed 320'F.14 Check RCPs-ANY RUNNING IF letdown in service, THEN perform the following:
  **xx***xxx*x*x*xx%%'ex                         xxk*xxxxx**%x**x%'*xx NOTE:     Actual   PRZR pressure should be verified by more than     1 indicator.
a.Open AUX spray valve, AOV-296, as necessary to control PRZR pressure.b.Go to Step 16.
1 Check PRZR Pressure:                         IF one pressure    channel deviates significantly    from the other 3, o All 4 narrow range channels           THEN   perform the following:
EOP: P-PRZR.1'f!TLE: ABNORMAL PRESSURIZER PRESSURE REV 7 PAGE 10 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If either RCP is off, then the associated PRZR spray valve controller should be placed in MANUAL with demand at 0%.15 Check PRZR Spray Valve Controllers Demand-GREATER THAN 0%~PCV-431A~PCV-431B Place PRZR spray valve controllers in MANUAL and open as required to control pressure.16 Check PRZR Pressure-TRENDING TO 2235 PSIG IF PRZR pressure continues to increase uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP or SAFETY INJECTION.
APPROXIMATELY EQUAL
17 Check PRT Indications:
: a. IF the controlling PRZR pressure o  All 4  narrow range channels                channel has failed, THEN place TRENDING TOGETHER                          controller,   431K,   in MANUAL and adjust output to restore         PRZR pressure.
a.Level-BETWEEN 61%AND 84%a.Drain PRT to RCDT using PRT drain valve, AOV-526.b.Pressure-APPROXIMATELY 1.5 PSIG AND STABLE c.Temperature
: b. Refer to ER-INST.l,       REACTOR PROTECTION BISTABLE DEFEAT AFTER INSTRUMENTATION LOOP FAILURE.
-AT CNMT AMBIENT TEMPERATURE AND STABLE b.Open PRT vent, AOV-527.IF PRT pressure will NOT decrease, THEN open PRT drain valve, AOV-526, to reduce pressure.c.To feed and bleed the PRT, perform the following:
2 Check Reactor Power STABLE                 IF the abnormal,   PRZR   pressure is   a result of   a power   transient,   THEN evaluate conditions and go to the appropriate plant procedure.
1)Start a RMW pump.2)Verify RMW to CNMT isolation valve, AOV-508, open.3)Feed and bleed the PRT using PRT fill valve from'RMW, AOV-548, and PRT drain valve, AOV-526.
3 Check PRZR Pressure:
EOP:~W P-PRZR.1 TITLE: ABNORMAL PRESSURIZER PRESSURE REV'PAGE ll of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Refer to 0-9.3, NRC IMMEDIATE NOTIFICATION, for reporting requirements.
: a. Pressure   - LESS THAN 2235 PSIG       a. Go  to Step  12
18 Notify Higher Supervision-END-}}
: b. Pressure   - GREATER THAN 2000 PSIG     b. IF pressure decreasing uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP   OR SAFETY   INJECTION.
 
EOP:           TITLE REV: 7 P-PRZR.1                 ABNORMAL PRESSURIZER PRESSURE PAGE 4 of ll STEP     ACTION/EXPECTED RESPONSE             RESPONSE   NOT OBTAINED
  **x***xx x x**xx x x 4*x x x x x
                      ~
CAUTION w ~ *x x   x x**x*******
OBSERVE D/G LOADING LIMITS OF 2300 KW FOR 1/2 HOUR, 2250 KW FOR 2 HOURS, AND 1950 KW FOR CONTINUOUS SERVICE.
  *******xx*xx*xxxxxxxxxx>x****xx**xx**x*
4 Check PRZR Heater     Status:
: a. PRZR heater control group             a. Place   PRZR heater control group BREAKER CLOSED                            switch to TRIP to reset, then place switch to CLOSE and let return to AUTO.
: b. PRZR heater backup group - ON       b. IF   PRZR pressure less than 2220 psig, THEN energize PRZR backup heaters.
IF PRZR backup heater breaker has tripped,   THEN perform the following:
: 1) Place the breaker switch to OFF to reset breaker.
: 2) Place the breaker switch to ON to energize heaters.
: 3) Verify load increase   on Bus 16.
 
1 EOP:             TITLE:
REV' P-PRZR.1                   ABNORMAL PRESSURIZER PRESSURE PAGE 5   of 11 STEP     ACTION/EXPECTED RESPONSE             RESPONSE   NOT OBTAINED 5 Verify Normal PRZR Spray               Place   controllers in   MANUAL at 0%
Valve Controllers        DEMAND AT      demand.     IF valves can NOT be 0~o                                      closed, THEN perform the following:
: a. Trip the reactor.
: b. Trip the associated     RCP.
: c. Go to E-O,   REACTOR TRIP OR SAFETY INJECTION.
NOTE:     With PRZR pressure controller 431K in manual,     PORV-431C will not be operable in the automatic mode.
6 Check PRZR Pressure                     Place 431K    in MANUAL and decrease Controller, 431K, Demand               output   t:o energize PRZR heaters.
LESS THAN 504
 
I ll 0
ts
 
EOP:
REV: 7 P-PRZR. 1                 ABNORMAL PRESSURIZER   PRESSURE PAGE 6 of 11 STEP       ACTION/EXPECTED RESPONSE         RESPONSE   NOT OBTAINED 7 Check PRZR PORVs:
: a. PORVs - CLOSED                   a. Manually close PORVs.
IF any valve can NOT be closed, THEN   manually close the associated block valve.
                                                    ~ MOV-516   for PCV-430
                                                    ~ MOV-515   for PCV-431C
: b. Annunciator F-19, PRZR   PORV       b. IF   PORV   leakage is indicated, OUTLET HI TEMP 145'F                  THEN   perform the following:
EXTINGUISHED
: 1) Close     PORV block valves one at a time AND check   if pressure stabilizes.
                                                      ~ MOV-515
                                                      ~ MOV-516
: 2) IF a leaking     PRZR PORV is identified,   THEN restore any nonleaking PORV to operable AND go to Step 8.
: c. Go to Step  9
 
I EOP:              TITLE REV: 7 P-PRZR.1                   ABNORMAL PRESSURIZER   PRESSURE PAGE 7   of 11 STEP       ACTION/EXPECTED RESPONSE         RESPONSE NOT OBTAINED 8 Attempt To Reseat Any Leaking PORV:
: a. Verify affected   PORV block valve a. Close the   affected PORV block CLOSED                              valve.
: b. Cycle the leaking     PORV open then closed
: c. Open affected   PORV block valve
: d. Verify leakage   has stopped       d. IF leakage continues,   THEN perform the following:
: 1) Reclose leaking PORV block valve.
: 2) Refer to Tech Spec section 3.1.1.4 for required actions.
: e. Go  to Step  11
 
(
    ~q I
4~ '
 
EOP:             TITLE:
REV    7 P-PRZR.1                   ABNORMAL PRESSURIZER       PRESSURE PAGE 8   of 11 STEP       ACTION/EXPECTED RESPONSE             RESPONSE   NOT OBTAINED
  **x**x*xx*x**xxx%xx%***x*x*****xx**x** CAUTION o   IF PRZR PRESSURE IS TO BE REDUCED WHILE AT POWER, IT SHOULD BE DONE SLOWLY SINCE THE PRZR LOW PRESSURE TRIP IS RATE SENSITIVE.
o WHEN REDUCING PRZR PRESSURE,   OT4T SETPOINT WILL DECREASE.
  ******%**x'****%                   x*x x x*x ***x******%'***x***
9 Check PRZR Safety Valves:                 IF safety valve leakage indicated, THEN    perform the following to o Position indicator - LESS THAN       attempt to reseat the leaking valve:
0.1 INCH.
: a. SLOWLY    reduce PRZR pressure o Annunciator F-18, PRZR SAFETY             (remain above 2000 psig).
VLV OUTLET HI TEMP 145'F EXTINGUISHED                         b. IF symptoms indicate leakage has stopped, THEN restore pressure o Annunciator AA-13, PRESSURIZER           to normal.
SAFETY VALVE POSITION EXTINGUISHED                           c. IF leakage recurs or can NOT be stopped, THEN perform the following:
: 1)  Verify leakage within limits of Tech Spec section 3.1.5.
: 2)  Go  to Step 17.
10  Check AUX Spray'alve,                      Manually close valve. IF valve can AOV-296  CLOSED                          NOT be closed, THEN consider isolating letdown and closing cha'rging flow control valve, HCV-142.
 
I' EOP:              TITLE:
REV: 7 P-PRZR.1                    ABNORMAL PRESSURIZER PRESSURE PAGE 9    of 11 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED 11    Check PRZR Pressure        Control Restored:
: a. Pressure    - TRENDING TO 2235 PSIG      a. IF pressure    continues to decrease,   THEN return to Step 1.
: b. Go to Step    17 12    Check PRZR Backup        Heaters-           Verify  PRZR   backup heater switch in OFF                                          AUTO, AND    ensure proper operation.
NOTE:     With PRZR pressure controller 431K in manual, PORV-431C          will not  be operable in the automatic mode.
13    Check PRZR Pressure                           Place 431K    in MANUAL at 50% demand.
Controller, 431K, Demand INCREASING NOTE:    o  If auxiliary spray  is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.
o  The bT between the REGEN Hx    charging outlet and the     PRZR shall  NOT exceed 320'F.
14  Check RCPs        ANY RUNNING                IF letdown in service,     THEN  perform the following:
: a. Open AUX spray valve, AOV-296, as necessary to control PRZR pressure.
: b. Go to Step 16.
 
EOP:              'f!TLE:
REV    7 P-PRZR.1                        ABNORMAL PRESSURIZER      PRESSURE PAGE 10      of 11 STEP      ACTION/EXPECTED RESPONSE                RESPONSE    NOT OBTAINED NOTE:     If either    RCP  is off, then the associated  PRZR  spray valve controller should be    placed in MANUAL with demand at    0%.
15    Check PRZR Spray Valve                        Place  PRZR spray valve    controllers Controllers        Demand    GREATER          in  MANUAL and open as required        to THAN 0%                                        control pressure.
          ~ PCV-431A
          ~ PCV-431B 16    Check PRZR        Pressure                    IF PRZR pressure continues to TRENDING TO 2235 PSIG                          increase uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP or SAFETY INJECTION.
17    Check PRT      Indications:
: a. Level -   BETWEEN 61% AND 84%            a. Drain    PRT to  RCDT  using  PRT drain valve,    AOV-526.
: b. Pressure     - APPROXIMATELY              b. Open PRT vent, AOV-527. IF          PRT 1.5 PSIG     AND STABLE                        pressure will NOT decrease,       THEN open PRT    drain valve, AOV-526, to reduce pressure.
: c. Temperature      - AT CNMT AMBIENT        c. To feed and bleed the PRT, TEMPERATURE AND STABLE                        perform the following:
: 1)  Start  a RMW pump.
: 2)  Verify RMW to    CNMT  isolation valve, AOV-508, open.
: 3) Feed and bleed the PRT using PRT  fill valve from'RMW, AOV-548, and PRT drain valve, AOV-526.
 
EOP:            TITLE:
~    W REV' P-PRZR.1                  ABNORMAL PRESSURIZER    PRESSURE PAGE ll of 11 STEP    ACTION/EXPECTED RESPONSE            RESPONSE NOT OBTAINED NOTE:  Refer to 0-9.3,  NRC IMMEDIATE NOTIFICATION, for reporting requirements.
18    Notify Higher Supervision
                                            -END-}}

Latest revision as of 17:18, 29 October 2019

Rev 7 to EOP AP-PRZR.1, Abnormal Pressurizer Pressure.
ML17263A810
Person / Time
Site: Ginna Constellation icon.png
Issue date: 09/21/1994
From: Marlow T
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17263A809 List:
References
AP-PRZR.1, NUDOCS 9410180209
Download: ML17263A810 (17)


Text

EOP: TITLE:

REV' P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 1 of 11 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC, REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

94iOi80209 940930 PDR ADDCK 05000244 P

4I EOP: TITLE:

REV 7 P-PRZR.l ABNORMAL PRESSURIZER PRESSURE PAGE 2 of 11 A. PURPOSE This procedure provides the actions necessary to mitigate the consequences of abnormal PRZR pressure.

B. ENTRY CONDITIONS/SYMPTOMS

l. ENTRY CONDITIONS This procedure is entered from:
a. AP-CVCS.1, CVCS LEAK, or b ~ AP FW 1 i PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER, or
c. AP-IA.1, LOSS OF INSTRUMENT AIR, or
d. AP-RCC.1, CONTINUOUS CONTROL ROD WITHDRAWAL OR INSERTION, or
e. AP-RCS.1, REACTOR COOLANT LEAK, or f AP TURB ~ 1 g TURBINE TRI P WITHOUT RX TRI P REQUIRED g or
g. AP-TURB.2, TURBINE LOAD REJECTION, when PRZR pressure can NOT be controlled.
2. SYMPTOMS The symptoms of ABNORMAL PRZR PRESSURE are;
a. Annunciator F-19, or PRZR PORV OUTLET HI TEMP 145'F, lit,
b. Annunciator F-18, PRZR SAFETY VLV OUTLET HI TEMP 145'F, lit, or
c. Annunciator AA-13, PRESSURIZER SAFETY VALVE POSITION, lit, or
d. Annunciator F-l, PRT LIQUID HI TEMP 220'F, lit, or
e. Annunciator F-9, PRT HI PRESS 5 PSI, lit, or
f. Annunciator F-17, PRT LEVEL 60.8 4 84.5, lit, or
g. Annunciator F-2, PRESSURIZER HI PRESS 2310 PSI, lit, or
h. Annunciator F-10, PRESSURIZER LO PRESS 2185 PSI, lit, or
i. Annunciator F-6, PRESSURIZER HEATER BREAKER TRIP, lit.
j. Annunciator F-26, 2377 PSI.

PRESSURIZER HI PRESS CHANNEL ALERT

EOP: TITLE:

REV: 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 3 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

                                  • 4 **% **% ****************

CAUTION IF, AT ANY TIME DURING THIS PROCEDURE, A REACTOR TRIP OR SI OCCURS, E-O, REACTOR TRIP OR SAFETY INJECTION, SHALL BE PERFORMED.

    • xx***xxx*x*x*xx%%'ex xxk*xxxxx**%x**x%'*xx NOTE: Actual PRZR pressure should be verified by more than 1 indicator.

1 Check PRZR Pressure: IF one pressure channel deviates significantly from the other 3, o All 4 narrow range channels THEN perform the following:

APPROXIMATELY EQUAL

a. IF the controlling PRZR pressure o All 4 narrow range channels channel has failed, THEN place TRENDING TOGETHER controller, 431K, in MANUAL and adjust output to restore PRZR pressure.
b. Refer to ER-INST.l, REACTOR PROTECTION BISTABLE DEFEAT AFTER INSTRUMENTATION LOOP FAILURE.

2 Check Reactor Power STABLE IF the abnormal, PRZR pressure is a result of a power transient, THEN evaluate conditions and go to the appropriate plant procedure.

3 Check PRZR Pressure:

a. Pressure - LESS THAN 2235 PSIG a. Go to Step 12
b. Pressure - GREATER THAN 2000 PSIG b. IF pressure decreasing uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP OR SAFETY INJECTION.

EOP: TITLE REV: 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 4 of ll STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

    • x***xx x x**xx x x 4*x x x x x

~

CAUTION w ~ *x x x x**x*******

OBSERVE D/G LOADING LIMITS OF 2300 KW FOR 1/2 HOUR, 2250 KW FOR 2 HOURS, AND 1950 KW FOR CONTINUOUS SERVICE.

              • xx*xx*xxxxxxxxxx>x****xx**xx**x*

4 Check PRZR Heater Status:

a. PRZR heater control group a. Place PRZR heater control group BREAKER CLOSED switch to TRIP to reset, then place switch to CLOSE and let return to AUTO.
b. PRZR heater backup group - ON b. IF PRZR pressure less than 2220 psig, THEN energize PRZR backup heaters.

IF PRZR backup heater breaker has tripped, THEN perform the following:

1) Place the breaker switch to OFF to reset breaker.
2) Place the breaker switch to ON to energize heaters.
3) Verify load increase on Bus 16.

1 EOP: TITLE:

REV' P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 5 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 5 Verify Normal PRZR Spray Place controllers in MANUAL at 0%

Valve Controllers DEMAND AT demand. IF valves can NOT be 0~o closed, THEN perform the following:

a. Trip the reactor.
b. Trip the associated RCP.
c. Go to E-O, REACTOR TRIP OR SAFETY INJECTION.

NOTE: With PRZR pressure controller 431K in manual, PORV-431C will not be operable in the automatic mode.

6 Check PRZR Pressure Place 431K in MANUAL and decrease Controller, 431K, Demand output t:o energize PRZR heaters.

LESS THAN 504

I ll 0

ts

EOP:

REV: 7 P-PRZR. 1 ABNORMAL PRESSURIZER PRESSURE PAGE 6 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Check PRZR PORVs:

a. PORVs - CLOSED a. Manually close PORVs.

IF any valve can NOT be closed, THEN manually close the associated block valve.

~ MOV-516 for PCV-430

~ MOV-515 for PCV-431C

b. Annunciator F-19, PRZR PORV b. IF PORV leakage is indicated, OUTLET HI TEMP 145'F THEN perform the following:

EXTINGUISHED

1) Close PORV block valves one at a time AND check if pressure stabilizes.

~ MOV-515

~ MOV-516

2) IF a leaking PRZR PORV is identified, THEN restore any nonleaking PORV to operable AND go to Step 8.
c. Go to Step 9

I EOP: TITLE REV: 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 7 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 8 Attempt To Reseat Any Leaking PORV:

a. Verify affected PORV block valve a. Close the affected PORV block CLOSED valve.
b. Cycle the leaking PORV open then closed
c. Open affected PORV block valve
d. Verify leakage has stopped d. IF leakage continues, THEN perform the following:
1) Reclose leaking PORV block valve.
2) Refer to Tech Spec section 3.1.1.4 for required actions.
e. Go to Step 11

(

~q I

4~ '

EOP: TITLE:

REV 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 8 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

    • x**x*xx*x**xxx%xx%***x*x*****xx**x** CAUTION o IF PRZR PRESSURE IS TO BE REDUCED WHILE AT POWER, IT SHOULD BE DONE SLOWLY SINCE THE PRZR LOW PRESSURE TRIP IS RATE SENSITIVE.

o WHEN REDUCING PRZR PRESSURE, OT4T SETPOINT WILL DECREASE.

            • %**x'****% x*x x x*x ***x******%'***x***

9 Check PRZR Safety Valves: IF safety valve leakage indicated, THEN perform the following to o Position indicator - LESS THAN attempt to reseat the leaking valve:

0.1 INCH.

a. SLOWLY reduce PRZR pressure o Annunciator F-18, PRZR SAFETY (remain above 2000 psig).

VLV OUTLET HI TEMP 145'F EXTINGUISHED b. IF symptoms indicate leakage has stopped, THEN restore pressure o Annunciator AA-13, PRESSURIZER to normal.

SAFETY VALVE POSITION EXTINGUISHED c. IF leakage recurs or can NOT be stopped, THEN perform the following:

1) Verify leakage within limits of Tech Spec section 3.1.5.
2) Go to Step 17.

10 Check AUX Spray'alve, Manually close valve. IF valve can AOV-296 CLOSED NOT be closed, THEN consider isolating letdown and closing cha'rging flow control valve, HCV-142.

I' EOP: TITLE:

REV: 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 9 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 11 Check PRZR Pressure Control Restored:

a. Pressure - TRENDING TO 2235 PSIG a. IF pressure continues to decrease, THEN return to Step 1.
b. Go to Step 17 12 Check PRZR Backup Heaters- Verify PRZR backup heater switch in OFF AUTO, AND ensure proper operation.

NOTE: With PRZR pressure controller 431K in manual, PORV-431C will not be operable in the automatic mode.

13 Check PRZR Pressure Place 431K in MANUAL at 50% demand.

Controller, 431K, Demand INCREASING NOTE: o If auxiliary spray is in use, spray flow may be increased by closing normal charging valve AOV-294 and normal PRZR spray valves.

o The bT between the REGEN Hx charging outlet and the PRZR shall NOT exceed 320'F.

14 Check RCPs ANY RUNNING IF letdown in service, THEN perform the following:

a. Open AUX spray valve, AOV-296, as necessary to control PRZR pressure.
b. Go to Step 16.

EOP: 'f!TLE:

REV 7 P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE 10 of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If either RCP is off, then the associated PRZR spray valve controller should be placed in MANUAL with demand at 0%.

15 Check PRZR Spray Valve Place PRZR spray valve controllers Controllers Demand GREATER in MANUAL and open as required to THAN 0% control pressure.

~ PCV-431A

~ PCV-431B 16 Check PRZR Pressure IF PRZR pressure continues to TRENDING TO 2235 PSIG increase uncontrollably, THEN trip the reactor and go to E-O, REACTOR TRIP or SAFETY INJECTION.

17 Check PRT Indications:

a. Level - BETWEEN 61% AND 84% a. Drain PRT to RCDT using PRT drain valve, AOV-526.
b. Pressure - APPROXIMATELY b. Open PRT vent, AOV-527. IF PRT 1.5 PSIG AND STABLE pressure will NOT decrease, THEN open PRT drain valve, AOV-526, to reduce pressure.
c. Temperature - AT CNMT AMBIENT c. To feed and bleed the PRT, TEMPERATURE AND STABLE perform the following:
1) Start a RMW pump.
2) Verify RMW to CNMT isolation valve, AOV-508, open.
3) Feed and bleed the PRT using PRT fill valve from'RMW, AOV-548, and PRT drain valve, AOV-526.

EOP: TITLE:

~ W REV' P-PRZR.1 ABNORMAL PRESSURIZER PRESSURE PAGE ll of 11 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Refer to 0-9.3, NRC IMMEDIATE NOTIFICATION, for reporting requirements.

18 Notify Higher Supervision

-END-