| title = LER 80-014/03L-0: on 800324,W/Reactor Shutdown for Refueling,6B2 Heater for Sbvs Discovered to Be Inoperable. Caused by Defective Thermocouple Amplifier (Fenwal Model 543) in 6B2 Heater Control Circuitry.Amplifier Replaced
| title = LER 80-014/03L-0: on 800324,w/reactor Shutdown for refueling,6B2 Heater for Sbvs Discovered to Be Inoperable. Caused by Defective Thermocouple Amplifier (Fenwal Model 543) in 6B2 Heater Control Circuitry.Amplifier Replaced
| author name = SHOPPMAN M
| author name = SHOPPMAN M
| author affiliation = FLORIDA POWER & LIGHT CO.
| author affiliation = FLORIDA POWER & LIGHT CO.

Revision as of 01:43, 27 February 2018

LER 80-014/03L-0: on 800324,w/reactor Shutdown for refueling,6B2 Heater for Sbvs Discovered to Be Inoperable. Caused by Defective Thermocouple Amplifier (Fenwal Model 543) in 6B2 Heater Control Circuitry.Amplifier Replaced
ML17266A199
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 04/23/1980
From: SHOPPMAN M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17208A556 List:
References
LER-80-014-03L, LER-80-14-3L, NUDOCS 8005080467