ML20062G718: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 2: Line 2:
| number = ML20062G718
| number = ML20062G718
| issue date = 11/20/1990
| issue date = 11/20/1990
| title = Forwards Inservice Insp Rept Unit 2 Catawba 1990 Refueling Outage 3 & Eddy Current Exam Rept Catawba Unit 2 June 1990 Refueling Outage 3.
| title = Forwards Inservice Insp Rept Unit 2 Catawba 1990 Refueling Outage 3 & Eddy Current Exam Rept Catawba Unit 2 June 1990 Refueling Outage 3
| author name = Tuckman M
| author name = Tuckman M
| author affiliation = DUKE POWER CO.
| author affiliation = DUKE POWER CO.

Latest revision as of 19:49, 6 January 2021

Forwards Inservice Insp Rept Unit 2 Catawba 1990 Refueling Outage 3 & Eddy Current Exam Rept Catawba Unit 2 June 1990 Refueling Outage 3
ML20062G718
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 11/20/1990
From: Tuckman M
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20062G720 List:
References
NUDOCS 9011300161
Download: ML20062G718 (1)


Text

..

+. Il I i

Duke heer Company (704)373 4 01)

' Nuclearl'roduction Department l'n Itm 1007 Charlotte, NC 28201 1007 DUKE POWER November 20, 1990 U. S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Subj ect: Catawba Nuclear Station Unit 2 Docket No. 50-414 End of Cycle.3 Inservice Inspection Report Gentlement Pursuant to 10 CFR 50.55a and Catawba Nuclear Station Technical Specification 4.0.5, find attached the Catawba Unit 2 End of Cycle 3 Inservice Inspection Report. The Catawba Unit 2 End of Cyclo 3 Inservice Inspection was completed on September 8, 1990. This Inservice Inspection was performed in accordance with Section XI of the ASME b Boiler and Pressuro Vessel Code and applicable addenda. Also attached is tt'a Catawba Unit 2 End of Cycle 3 Eddy Current Examination Report.

Very truly yours, TA -3 Sk M. S. Tuckman, Vice President Nuclear Operations

-CRL4/lcs Attachments xct. (W/0 Attachments)

Mr. S. D. Ebneter, Regional Administrator-U. S. Nuclear Regulatory Commission Region II 101 Marietta St...NW, Suite 2900

-Atlanta, Georgia 30323 Mr. W. T. Orders NRC Resident Inspector Catawba Nuclear Station Dh 901120 ~

{f011300161 ADOCK 05000434 PDC l

\\

.