ML20064J820: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
| number = ML20064J820
| number = ML20064J820
| issue date = 03/16/1994
| issue date = 03/16/1994
| title = Refueling Outage 16,Outage Dates 931029-1216,ISI Interval 2,Period 3.
| title = Refueling Outage 16,Outage Dates 931029-1216,ISI Interval 2,Period 3
| author name = Anderson R
| author name = Anderson R
| author affiliation = NORTHERN STATES POWER CO.
| author affiliation = NORTHERN STATES POWER CO.

Latest revision as of 13:33, 6 January 2021

Refueling Outage 16,Outage Dates 931029-1216,ISI Interval 2,Period 3
ML20064J820
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 03/16/1994
From: Richard Anderson
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20064J824 List:
References
NUDOCS 9403220093
Download: ML20064J820 (1)


Text

p ,- -

^4 Morttem States Power Company 414 Nicollet Mall Minneapolis, Minnesota 55401 1927 Telephone (612) 330-5500 March 16, 1994 U S Nuclear Regulatory Commission Attn Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-306 License No. DPR-60 Unit 2 Inservice Inspection Summary Report Refuelino Outace No. 16 During the 1993 Prairie Island Unit 2 refueling outage (Refueling Outage No.

16), the inservice inspection (ISI) examination for period three of the second 10 year interval was conducted. Attached for your information are four copies of the ISI examination Summary Report for this period.

The report identifies components examined, the examination methods used, the examination number, and summarizes the results. All anomalies were either corrected or an engineering evaluation was performed to accept "as is" conditions. A description of the corrective work and the corresponding work request numbers are provided in the ASME Section XI Repair \ Replacement portion of the report.

This Summary Report is being submnt cd in accordance with the Prairie Island ASME Code Section XI Inservice Inspsetion and Testing Program and is intended to satisfy the inspection reporting requirements contained in IWA-6220 of the ASME Boiler and Pressure Vessel Code.

Sincerely, MC Ro or O Anderson Director Licensing and Management Issues c Regional Administrator III, NRC (2 copies of attachment)

NRR Project Manager, NRC (1 copy of attachment)

Senior Resident Inspector, NRC (w\o attachment)

J E Silberg (w\o attachment)

Chief Boiler In9pector, State of MN (1 copy of attachment)

Paul Fisher, Hartford Ins. (1 copy of attachment)

Attachment u. nos m s

hkOA 4 -

9403220093 940316 ,

PDR ADOCK0500g6 s g

\\

w L: .

/