| issue date = 04/20/1995
| issue date = 04/20/1995
| title = Rev 12 to EOP ECA-3.3, SGTR W/O Pressurizer Pressure Control.
| title = Rev 12 to EOP ECA-3.3, SGTR W/O Pressurizer Pressure Control.
| author name = MARLOW T A
| author name = Marlow T
| author affiliation = ROCHESTER GAS & ELECTRIC CORP.
| author affiliation = ROCHESTER GAS & ELECTRIC CORP.
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:EOP:ECA-).3T1TLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE1of27ROCHESTERGASANDELECTRICCORPORATIONGINNASTATIONCONTROLLEDCOPYNUMBERTECHNICALREVIEWPORCREVIEWDATEW/'7PLANTSPERINTEDENTEFFECTIVEDATECATEGORY1.0REVIEWEDBY:QO'.9504280026950420PDRADOCK05000244IPPDR
{{#Wiki_filter:EOP:           T1TLE:
~Jv'Vh EOP:ECA-3.9IITITLESGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE2of27A.PURPOSE-ThisprocedureprovidesactionsforaSGTRwithcoincidentlossofnormalandauxiliaryPRZRspraysandPORVs.B.ENTRYCONDITIONS/SYMPTOMS1.ENTRYCONDITIONS-Thisprocedureisenteredfrom:a.E-3,STEAMGENERATORTUBERUPTURE,whenPRZRpressurecontrolisnotavailable.
REV: 12 ECA-).3       SGTR WITHOUT PRESSURIZER    PRESSURE CONTROL PAGE 1 of 27 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE    W /'7 PLANT S PERINTE DENT EFFECTIVE DATE CATEGORY  1.0 REVIEWED BY:
V EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE3of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:oFoldoutpageshouldbeopenANDmonitoredperiodically.oAdverseCNMTvaluesshouldbeusedwheneverCNMTpressureisgreaterthan4psigorCNMTradiationisgreaterthan10+5R/hr.1CheckRupturedS/GNarrowRangeLevel-LESSTHAN67%[554adverseCNMT]GotoStep8.2CheckRCPStatus-ATLEASTONERUNNINGTrytostartoneRCP:a.EstablishconditionsforstartingRCP.oBus11AandBusllBenergizedoRefertoAttachmentRCPSTARTb.StartoneRCP.IFnoRCPcanbestarted,THENgotoStep4.3CheckIFNormalPRZRSprayAvailable:a.VerifyIAtoCNMT-AVAILABLEa.Performthefollowing:1)PlacePRZRheatercontrolgrouptoPULLSTOP.2)PlacePRZRheaterbackupgrouptoOFF.3)PlacenormalsprayvalvecontrollerstoMANUALat0%.b.GotoE-3,STEAMGENERATORTUBERUPTURE,Step214)GotoStep4.
QO'.
<</'ll4 EOP:ECA-3.3TITLESGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE4of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED4TryToRestorePRZRPORV:a.Blockvalves-ATLEASTONEOPEN~MOV-516forPCV-430~MOV-515forPCV-431Ca.OpenoneblockvalveunlessitwasclosedtoisolateanopenPORV.IfblockvalvescanNOTbeopened,THENdispatchAOtolocallyensurebreakerstoblockvalvesclosed.b.CheckIAtoCNMT-AVAILABLEc.VerifyatleastonePRZRPORVflowpath-AVAILABLEd.GotoE-3,STEAMGENERATORTUBERUPTURE,Step22~MOV-515,MCCCposition6C~MOV-516,MCCDposition6Cb.RefertoAttachmentN2PORVStooperatePORVs.c.GotoStep5.
9504280026 950420 PDR  ADOCK 05000244 P                 PDR I
~J;r~~I~kf'~~P~'.
EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE5of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:IfauxiliarysprayistheonlymeansofRCSpressurecontrol,THENthe320'FATlimitbetweenthespraylineandPRZRdoesnotapply.5TryToEstablishAuxiliarySpray:a.Chargingpumps-ATLEASTONERUNNINGa.Performthefollowing:1)IFCCWflowislosttoanyRCPthermalbarrierORanyRCP&#xb9;1sealoutlettemperatureoffscalehigh,THENlocallyisolatesealinjectiontoaffectedRCP.~RCPA,V-300A~RCPB,V-300B2)EnsureHCV-142demandat0%.b.Establishauxiliarysprayflow:1)Openauxiliarysprayvalve(AOV-296)3)Startchargingpumpsasnecessary.IFchargingnotavailable,THENgotoStep6.b.IFauxiliaryspraycanNOTbeestablished,THENgotoStep6.2)ClosechargingvalvetoloopBcoldleg(AOV-294)c.GotoE-3,STEANGENERATORTUBERUPTURE,Step21b
/1%hht~WI~tI~J'~:4 EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE6of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED*****************************************CAUTIONIFCSTLEVELDECREASESTOLESSTHAN5FEET,THENALTERNATEWATERSOURCESFORAFWPUMPSWILLBENECESSARY(REFERTOER-AFW.1)ALTERNATEWATERSUPPLYTOAFWPUMPS).NOTE:TDAFWpumpflowcontrolvalvesfailopenonlossofIA.*6MonitorIntactS/GLevel:a.Narrowrangelevel-GREATERTHAN5%[25%adverseCNMT]b.Controlfeedflowtomaintainnarrowrangelevelbetween17%[25%adverseCNMT]and50%a.Maintaintotalfeedflowgreaterthan200gpmuntilnarrowrangelevelgreaterthan5%[25%adverseCNMT)inatleastoneS/G.b.IFnarrowrangelevelinintactS/Gcontinuestoincreaseinanuncontrolledmanner,THENgotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLEDRECOVERYDESIRED,Step1.7CheckPRZRLevel-GREATERTHAN54[304adverseCNMT]ReturntoStepl.
~4A4P EOP:Ec.A-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE7of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED8CheckIfSICanBeTerminated:a.RCSsubcoolingbasedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLINGb.Secondaryheatsink:oTotalfeedflowtoS/GsGREATERTHAN200GPMAVAILABLE-OR-a.DoNOTstopSIpumps.GotoECA-3',SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLEDRECOVERYDESIRED,Step1.b.IFneitherconditionsatisfied,THENdoNOTstopSIpumps.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLEDRECOVERYDESIRED,Step1.oNarrowrangelevelinintactS/G-GREATERTHAN5%[25%adverseCNMT]c.RVLISindicationoLevel(noRCPs)-GREATERTHAN68%[73%adverseCNMT]-OR-c.DoNOTstopSIpumps.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLEDRECOVERYDESIRED,Stepl.oFluidfraction(anyRCPrunning)-GREATERTHAN80%d.AnyrupturedS/Gnarrowrangelevel-INCREASINGINANUNCONTROLLEDMANNEROROFFSCALEHIGHd.DoNOTstopSIpumps.ReturntoStep2.
;rI~ktl+>>E
~'EOP:ECA-3.31T1TLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE8of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED9StopSIPumpsandPlaceInAUTO
~~
EOP:ECA-3.3T!TLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE9of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED10CheckIfChargingFlowHasBeenEstablished:a.Chargingpumps-ANYRUNNINGb.ChargingpumpsuctionalignedtoRWST:oLCV-112B-OPENoLCV-112C-CLOSEDc.Startchargingpumpsasnecessaryandadjustchargingflowtoperformthefollowing:oRestorePRZRleveloMaintainRCSsubcoolingbasedoncoreexitT/Cs-GREATERTHANO'FUSINGFIGUREMINSUBCOOLINGa.Performthefollowing:1)IFCCWflowislosttoanyRCPthermalbarrierORanyRCP&#xb9;1sealoutlettemperatureoffscalehigh,THENdispatchAOwithkeytoRWSTgatetoclosesealinjectionneedlevalve(s)toaffectedRCP:~RCPA,V-300A~RCPB,V-300B2)EnsureHCV-142open,demandat0%.b.Manuallyalignvalvesasnecessary.IFLCV-112BcanNOTbeopened,THENperformthefollowing:1)VerifychargingpumpANOTrunningandplaceinPULLSTOP.2)DispatchAOtolocallyopenmanualchargingpumpsuctionfromRWST(V-358locatedinchargingpumproom).3)WHENV-358open,THENdirectAOtocloseV-268toisolatechargingpumpsBandCfromVCT(V-268locatedinchargingpumproom).
~I'4.I',4*4ge'I ECA-3.3TITLESGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE10of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED*11MonitorRCSInventory:oRCSsubcoolingbasedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLINGoRVLISindicationoLevel(noRCPs)-GREATERTHAN68%[73%adv'erseCNMT]-OR-Performthefollowing:a.ManuallyoperateSIpumpsasnecessary.b.GotoECA-3.1,SGTRWITHLOSSOFREACTORCOOLANT-SUBCOOLEDRECOVERYDESIRED,Step1.oFluidfraction(anyRCPrunning)-GREATERTHAN80%12VerifyAdequateSWFlowToCCWHx:a.VerifyatleasttwoSWpumpsRUNNINGb.VerifyAUXBLDGSWisolationvalves-OPENa.Manuallystartpumpsaspowersupplypermits(258kwperpump).IFlessthantwoSWpumpscanbeoperated,THENgotoStep20.b.EstablishSWtoAUXBLDG(RefertoAttachmentAUXBLDGSW).~MOV-4615andMOV-4734~MOV-4616andMOV-4735c.VerifyCNMTRECIRCfanannunciatorC-2,HIGHTEMPERATUREALARM-EXTINGUISHEDc.DispatchAOtolocallythrottleflowtoCCWHxtobetween5000gpmand6000gpmtotalflow.
~k44t[~,gag EOP:ECA-3.31'ITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE11of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED13CheckIfNormalCVCSOperationCanBeEstablisheda.VerifyIArestored:oIAtoCNMT(AOV-5392)-OPENa.ContinuewithStep17.WHENIArestored,THENdoSteps13through16.oIApressure-GREATERTHAN60PSIGb.VerifyinstrumentbusD-ENERGIZEDc.CCWpumps-ANYRUNNINGb.EnergizeMCCB.IFMCCBNOTavailable,THENperformthefollowing:1)VerifyMCCAenergized.2)PlaceinstrumentbusDonmaintenancesupply.c.Performthefollowing:1)IFanyRCP81sealoutlettemperatureoffscalehigh,THENisolateCCWtothermalbarrierofaffectedRCP(s).~RCPA,MOV-749AandMOV-759A~RCPB,MOV-749BandMOV-759Bd.Chargingpump-ANYRUNNING2)ManuallystartoneCCWpump.d.ContinuewithStep20.WHENanychargingpumprunning,THENdoSteps14through17.
pl'14l)\544,t EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE12of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:IfPRZRlevelislessthan13%,letdownmaybeestablishedbyplacingAOV-427toOPEN.14EstablishNormalLetdown:a.EstablishcharginglineflowtoREGENHx-GREATERTHAN20GPMb.PlacethefollowingswitchestoCLOSE:~Letdownorificevalves(AOV-200A,AOV-200B,andAOV-202)~AOV-371,letdownisolationvalve~AOV-427,loopBcoldlegtoREGENHxc.PlaceletdowncontrollersinMANUALat40%open~TCV-130~PCV-135d.ResetbothtrainsofXYrelaysforAOV-371andAOV-427e.OpenAOV-371andAOV-427f.Openletdownorificevalvesasnecessaryg.PlaceTCV-130inAUTOat105'Fh.PlacePCV-135inAUTOat250psigi.AdjustchargingpumpspeedandHCV-142asnecessaryIFRCPsealreturnhasbeenestablished,THENestablishexcessletdownasfollows:oPlaceexcessletdowndivertvalve,AOV-312,toNORMAL.oEnsureCCWfromexcessletdownopen,(AOV-745).oOpenexcessletdownisolationvalveAOV-310.oSlowlyopenHCV-123tomaintainexcessletdowntemperaturelessthan195'Fandpressurelessthan100psig.oAdjustchargingpumpspeedasnecessary.IFRCPsealreturnNOTestablished,THENconsultTSCtodetermineifexcessletdownshouldbeplacedinservice.
g'sr,lIEF EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE13of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED15CheckVCTMakeupSystem:a.AdjustboricacidflowcontrolvalveinAUTOto9.5gpmb.Verifythefollowing:1)RMWmodeselectorswitchinAUTOb.Adjustcontrolsasnecessary.2)RMWcontrolarmed-REDLIGHTLITc.CheckVCTlevel:oLevel-GREATERTHAN20%-OR-oLevel-STABLEORINCREASINGc.ManuallyincreaseVCTmakeupflowasfollows:1)EnsureBAtransferpumpsandRMWpumpsrunning.IFNOT,THENresetMCCCandMCCDUVlockoutsasnecessary.2)PlaceRMWflowcontrolvalveHCV-111inMANUAL.3)IncreaseRMWflow.'
p%AtdQI'~-1k.ip EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE14of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED16CheckChargingPumpSuctionAlignedToVCT:a.VCTlevel-GREATERTHAN20%a.IFVCTlevelcanNOTbemaintainedgreaterthan5%,THENperformthefollowing:1)EnsurechargingpumpsuctionalignedtoRWSToLCV-112BopenoLCV-112Cclosed.b.VerifychargingpumpsalignedtoVCToLCV-112C-OPENoLCV-112B-CLOSED2)ContinuewithStep17.WHENVCTlevelgreaterthan40%,THENdoStep16b.b.Manuallyalignvalvesasnecessary.
~t/g~l~~e~'Iij4Iq'L,>
4~EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE15of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED17CheckRCPCooling:a.CheckCCWtoRCPs:EstablishnormalcoolingtoRCPs(RefertoAttachmentSEALCOOLING).oAnnunciatorA-7,RCP1ACCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHEDioAnnunciatorA-15,RCP1BCCWRETURNHIGHTEMPORLOWFLOWEXTINGUISHEDb.CheckRCPsealinjection:oLabyrinthsealD/Ps-GREATERTHAN15INCHESOFWATER-OR-oRCPsealinjectionflowtoeachRCP-GREATERTHAN6GPM rp1>~JI
~~EOP:ECA-P.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE16of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED18CheckIfSealReturnFlowShouldBeEstablished:a.VerifyRCP&#xb9;1sealoutlettemperature-LESSTHAN235'Fb.VerifyRCPsealoutletvalvesOPEN~AOV-270A~AOV-270Ba.GotoStep19.b.Manuallyopenvalvesasnecessary.c.ResetbothtrainsofXYrelaysforRCPsealreturnisolationvalveMOV-313d.OpenRCPsealreturnisolationvalveMOV-313d.Performthefollowing:1)PlaceMOV-313switchtoOPEN.e.VerifyRCP&#xb9;1sealleakoffflowLESSTHAN5.5GPM2)DispatchAOwithkeytoRWSTgatetolocallyopenMOV-313.e.Performthefollowing:1)TriptheaffectedRCP2)Allow3minutesforpumpcoastdown,THENclosetheaffectedRCPsealdischargevalve.RCPA,AOV-270A~RCPB,AOV-270BIFbothRCPsealdischargevalvesareshut,THENgotoStep19.f.VerifyRCP&#xb9;1sealleakoffflowGREATERTHAN0.8GPMf.RefertoAP-RCP.1,RCPSEALMALFUNCTION.  
~'1k*Cp
~s~~~EOP:ECA-0.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE17of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED19EqualizeChargingAndLetdownFlows:a.Verifychargingpumpcontrollersinmanualb.Controlchargingandsealinjectionflowstoequalletdownandsealleakoffflows20CheckIfEmergencyD/GsShouldBeStopped:a.VerifyACemergencybussesenergizedbyoffsitepower:oEmergencyD/GoutputbreakersOPENa.Trytorestoreoffsitepower(RefertoER-ELEC.1,RESTORATIONOFOFFSITEPOWER).oACemergencybusvoltage-GREATERTHAN420VOLTSoACemergencybusnormalfeedbreakers-CLOSEDb.StopanyunloadedemergencyD/Gandplaceinstandby(RefertoAttachmentD/GSTOP)21MinimizeSecondarySyst:emContamination:a.IsolaterejectfromhotwelltoCST'Placehotwelllevelcontroller(HC-107)inMANUALat50%a.IFhotwelllevelincreasing,THENdirectRPtosamplehotwellsforactivity.KoVerifyhotwelllevel-STABLEb.VerifylocalactionstocompleteisolationofrupturedS/G(RefertoAttachmentRUPTUREDS/G)
~~Ce90l1 EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE18of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:AdverseCNMTconditionsorlossofforcedaircoolingmayresultinfailureofNISdetectors.22CheckIfSourceRangeDetectorsShouldBeEnergized:a.SourcerangechannelsDEENERGIZEDa.GotoStep22e.b.Checkintermediaterangeflux-EITHERCHANNELLESSTHAN1010AMPSb.Performthefollowing:1)IFneitherintermediaterangechannelisdecreasing,THENinitiateboration.2)ContinuewithStep23.WHENfluxisLESSTHAN10-10~psonanyoperablechannel,THENdoSteps22cthroughe.c..Checkthefollowing:oBothintermediaterangechannels-LESSTHAN1010AMPSc.ContinuewithStep23.WHENeitherconditionmet,THENdoSteps22dande.-OR-oGreaterthan20minutessincereactortripd.VerifysourcerangedetectorsENERGIZEDd.ManuallyenergizesourcerangedetectorsbydepressingP-6permissivedefeatpushbuttons(2of2).e.TransferRk-45recordertoonesourcerangeandoneintermediaterangechannelIFsourcerangescanNOTberestored,THENrefertoER-NIS.1,SRMALFUNCTIONandgotoStep22.
~~
EOP:EGA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE19of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED23EstablishNormalShutdownAlignment:a.Checkcondenser-AVAILABLEa.DispatchAOtoperformAttachmentSD-2.b.Performthefollowing:oOpengeneratordisconnects~1G13A71~9X13A73oPlacevoltageregulatortoOFFoOpenturbinedrainvalvesoRotatereheatersteamsupplycontrollercerntoclosevalves'PlacereheaterdumpvalveswitchestoHANDoStopallbutonecondensatepumpc.VerifyadequateRxheadcooling:1)CheckIAtoCNMT-AVAILABLE1)GotoStep24.2)Verifyatleastonecontrolrodshroudfan-RUNNING3)VerifyoneRxcompartmentcoolingfan-RUNNING2)Manuallystartonefanaspowersupplypermits(45kw)3)Performthefollowing:oDispatchAOtoresetUVrelaysatMCCCandMCCD.oManuallystartonefanaspowersupplypermits(23kw)d.VerifyAttachmentSD-1-COMPLETE
)w'o~rIT EOP:ECA-3.3IT!TLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE20of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:PlantstaffshoulddecidewhethertorepairPRZRpressurecontrolsystemsorcontinuewiththisprocedure.IfPRZRpressurecontrolisestablished,PRZRlevelshouldberestoredtogreaterthan5%[30%adverseCNMT]andthenfurtherrecoveryshouldcontinuewithE-3,STEAMGENERATORTUBERUPTURE,Step37.24CheckIfSIACCUMsShouldBeIsolated:a.Checkthefollowing:oRCSsubcoolingbasedoncoreexitT/Cs-GREATERTHANO'USINGFIGUREMINSUBCOOLINGa.ReturntoStep11.oRVLISindication-GREATERTHAN68%[73%adverseCNMT]b.DispatchAOwithlockedvalvekeytolocallyclosebreakersforSIACCUMdischargevalves~MOV-841,MCCCposition12F~MOV-865,MCCDposition12Cc.CloseSIACCUMdischargevalves~MOV-841~MOV-865c.VentanyunisolatedACCUMs:1)OpenventvalvesforunisolatedSIACCUMs.~ACCUMA,AOV-834A~ACCUMB,AOV-834Bd.LocallyreopenbreakersforMOV-841andMOV-8652)OpenHCV-945.
IgCSItIfti!p EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE21of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:LeakagefromrupturedS/GintoRCSwilldiluteRCSboronconcentration.25VerifyAdequateShutdownMargina.DirectRPtosampleRCSandrupturedS/Gforboronconcentrationb.Verifyboronconcentration-GREATERTHANREQUIREMENTSOFFIGURESDMb.Borateasnecessary.26MaintainRequiredRCPSealInjectionFlowAndLabyrinthSealD/P:oLabyrinthsealD/PtoeachRCP-GREATERTHAN15INCHES,OFWATERoRCPsealinjectionflow-GREATERTHAN6GPMPerformthefollowing:oAdjustchargingflowtoREGENHx,HCV-142asnecessary.-OR-oDispatchAOtoadjustsealinjectionneedlevalvesV-300AandV-300Bifnecessary.27InitiateRCSCooldownto350'FInRCSColdLegs:a.EstablishandmaintaincooldownrateinRCScoldlegs-LESSTHAN100'F/HRb.DumpsteamtocondenserfromintactS/Gb.ManuallyorlocallydumpsteamusingintactS/GARV.IFnointactS/Gavailable,THENusefaultedS/G.
~~
EOP:EGA-).3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE22of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED*****************************************CAUTIONRCSANDRUPTUREDS/GPRESSURESMUSTBEMAINTAINEDLESSTHANTHERUPTUREDS/GARVSETPOINT.28ControlChargingFlowToMaintainRCSSubcooling:a.RCSsubcoolingbasedoncoreexitT/Cs-GREATERTHAN20'FUSINGFIGUREMINSUBCOOLINGb.RupturedS/GnarrowrangelevelLESSTHAN90%[85%adverseCNMT]c.RupturedS/GnarrowrangelevelSTABLEORDECREASINGa.Increasechargingflowtomaintainsubcoolinggreaterthan20'FusingFigureMINSUBCOOLINGandgotoStep29.b.ControlchargingflowtomaintainRCSpressureatrupturedS/GpressureandgotoStep29.c.IFrupturedS/Glevelincreasing,THENdecreasechargingflowtostabilizelevel.MaintainRCSsubcoolinggreaterthan20'FusingFigureMINSUBCOOLING.29CheckIfRCSCooldownShouldBeStopped:a.RCScoldlegtemperatures-LESSTHAN350'Fa.ReturntoStep25.b.StopRCScooldown tgl'IA+
EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE23of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED30CheckRCSPressure-GREATERTHAN400PSIG[300PSIGadverseCNMT]GotoStep33'31MonitorRupturedS/GNarrowRangeLevel-GREATERTHAN17%r25%adverseCNMT]RefillrupturedS/Gto67%[55%adverseCNMT]usingfeedflow.IFeitherofthefollowingconditionsoccurs,THENstopfeedflowtorupturedS/G:oRupturedS/Gpressuredecreasesinanuncontrolledmanner.-OR-oRupturedS/Gpressureincreasesto1020psig.e
~I EOP:ECA-3.3TITLESGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE24of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED*****************************************CAUTIONoSTEAMSHOULDNOTBERELEASEDFROMARUPTUREDS/GIFWATERMAYEXISTINITSSTEAMLINE.oRUPTUREDS/GPRESSUREMAYDECREASERAPIDLYWHENSTEAMISRELEASED.NOTE:TheupperheadregionmayvoidduringRCSdepressurizationifRCPsarenotrunning.ThismayresultinarapidlyincreasingPRZRlevel.32DepressurizeRCSAndRupturedS/GTo400PSIGt'300PSIGadverseCNMT]a.Performthefollowing:oDecreasechargingandincreaseletdowntoinitiatebackfill-OR-oInitiateblowdownfromrupturedS/G-OR-oDumpsteamfromrupturedS/Gb.CheckRCSpressure-LESSTHAN400psig[300psigadverseCNMT]c.StopRCSdepressurizationb.ReturTLtoStep31.
1I'p'bl"g'"I>as0 EOP:ECA-3.3ITITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE25of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED33CheckIfRHRNormalCoolingCanBeEstablished:a.RCScoldlegtemperature-LESSTHAN350'Fa.ReturntoStep27.b.RCSpressure-LESSTHAN400psig[300psigadverseCNMT]c.PlaceRCSoverpressureprotectionsysteminservice(Referto0-7,ALIGNMENTANDOPERATIONOFTHEREACTORVESSELOVERPRESSUREPROTECTIONSYSTEM)d.EstablishRHRnormalcooling(RefertoAttachmentRHRCOOL)b.ReturntoStep31.c.IFRCSoverpressureprotectionsystemcanNOTbeplacedinservice,THENnotifyTSCofpotentialTechSpecviolationifRHRsystemisplacedinservice.NOTE:LeakagefromrupturedS/GintoRCSwilldiluteRCSboronconcentration.34VerifyAdequateShutdownMargina.DirectRPtosampleRCSandrupturedS/Gforboronconcentrationb.Verifyboronconcentration-GREATERTHANREQUIREMENTSOFFIGURESDMb.Borateasnecessary.
14I7' EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE26of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED35InitiateRCSCooldownToColdShutdown:a.EstablishandmaintaincooldownrateinRCScoldlegs-LESSTHAN100'F/HRb.UseRHRsystemifinservicec.DumpsteamtocondenserfromintactS/Gc.ManuallyorlocallydumpsteamfromintactS/GusingARVs.IFnointactS/GavailableandRHRsystemNOTinservice,THENusefaultedS/G.36ControlChargingFlowToMaintainRCSSubcooling:a.RCSsubcoolingbasedoncoreexitT/Cs-GREATERTHAN20'FUSINGFIGUREMINSUBCOOLINGb.RupturedS/GnarrowrangelevelLESSTHAN90%[85%adverseCNMT)c.RupturedS/GnarrowrangelevelSTABLEORDECREASINGa.Increasechargingflowtomaintainsubcoolinggreaterthan20'FusingFigureMINSUBCOOLINGandgotoStep37.b.ControlchargingflowtomaintainRCSpressureatrupturedS/GpressureandgotoStep37.c.IFrupturedS/Glevelincreasing,THENdecreasechargingflowtostabilizelevel.MaintainRCSsubcoolinggreaterthan20'FusingFigureMINSUBCOOLING~
Ig'.I\
EOP:ECA-,3.3IT1TLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE27of27STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED*37MonitorRCPOperation:a.RCPs-ANYRUNNINGb.Checkthefollowing:oRCP&#xb9;1sealD/P-GREATERTHAN220PSIDa.GotoStep39.b.StoptheaffectedRCP(s).oCheckRCPsealleakageWITHINTHENORMALOPERATINGRANGEOFFIGURERCPSEALLEAKOFF38CheckCoreExitT/Cs-LESSTHAN200'FReturntoStep34.39EvaluateLongTermPlantStatus:a.Maintaincoldshutdownconditionsb.ConsultTSC-END-


EOP:ECA-3.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE1of1ECA-3.3APPENDIXLISTTITLEPAGES1)REDPATHSUMMARY2)FIGUREMINSUBCOOLING3)FIGURESDM4)FIGURERCPSEALLEAKOFF5)ATTACHMENTRCPSTART6)ATTACHMENTN2PORVS7)ATTACHMENTRUPTUREDS/G8)ATTACHMENTD/GSTOP9)ATTACHMENTSD-110)ATTACHMENTSEALCOOLING11)ATTACHMENTSD-212)ATTACHMENTRHRCOOL13)ATTACHMENTAUXBLDGSW14)FOLDOUT Jf EOP:,ECA-~.3TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE1of1REDPATHSUMMARYa.SUBCRITICALITY-Nuclearpowergreaterthan5tb.CORECOOLING-CoreexitT/Csgreaterthan1200'F-OR-CoreexitT/Csgreaterthan700'FANDRVLISlevel(noRCPs)lessthan434[464adverseCNMT]c.HEATSINK-NarrowrangelevelinallS/Gslessthan54[254adverseCNMT]ANDtotalfeedwaterflowlessthan200gpmd.INTEGRITY-Coldlegtemperaturesdecreasegreaterthan100Finlast60minutesANDRCScoldlegtemperaturelessthan285'Fe.CONTAINMENT-CNMTpressuregreaterthan60psig 0~fr>,(JlOhpl/
      ~ J v
EOP:ECA-3.3~z~~TITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE1of1FIGUREMINSUBCOOLINGNOTE:SubcoolingMargin=SaturationTemperatureFromFigureBelow[-]CoreExitT/CIndicationRC250024002300220021002000190018001700160015001300120011001000900800700'005004003002001000SPRESSURE(PSIG)RCSPRESSUREINCREMENTS20PSIGSUBCOOLEDREGIONADVERSECNMTNORMALCNMTINADEQUATESUBCOOLINGREGIONTEMPERATUREINCREMENTS10'F200250300350400450500550600650700COREEXITSATURATIONTEMPERATURE('F)  
V h
~~qsl.'V4 EOP:EGA,-3~3TITLESGTRWITHOUTPRESSURIZERPRESSURECONTROLREV12PAGE1of1FIGURESDMNOTE:oCurveincludesallowanceforonestuckrod.Add100ppmforeachadditionalstuckrod.oToobtaincoreburnup,usePPCSpointIDBURNUP.BORONCONCENTRATION(PPM)18001600BORONINCREMENTS20PPH140012001000ADEQUATESDH100PPHCONSERVATISHINCLUDED800600400200BURNUPINCREMENTS100MWD/MTU0100020003000400050006000700080009000100001100012000CYCLE25BURNUP(MWD/MTU)
 
I'i~0~'tCa~'l(Af~<4(j EOP:ECA-3.3~rTITLE:SGTRWITHOUTPRESSURIZERPRESSURECONTROLREV:12PAGE1of1FIGURERCPSEALLEAKOFF&#xb9;1SEALLEAKRATE(GPH)6LEAKRATEINCREHENTS0.2GPHNORHALOPERATINGRANGEDPINCREHENTS50PSI2505007501000125015001750200022502500&#xb9;1SEALDP(RCSPRESS-VCTPRESS)PSI  
EOP:            TITLE REV: 12 ECA-3. 9    SGTR WITHOUT PRESSURIZER PRESSURE    CONTROL I  I PAGE 2  of 27 A. PURPOSE      This  procedure provides actions for a SGTR with coincident loss of normal and auxiliary PRZR sprays and PORVs.
~eW~'  
B. ENTRY CONDITIONS/SYMPTOMS
}}
: 1. ENTRY CONDITIONS  This    procedure  is entered from:
: a. E-3, STEAM GENERATOR TUBE RUPTURE, when  PRZR pressure control is not available.
 
V EOP:            TITLE:
REV    12 ECA-3.3        SGTR WITHOUT PRESSURIZER PRESSURE              CONTROL PAGE 3    of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED NOTE:  o  Foldout page should be open    AND monitored periodically.
o  Adverse    CNMT  values should be used whenever CNMT pressure is greater    than  4 psig or CNMT radiation is greater than 10+ 5 R/hr.
1 Check Ruptured S/G Narrow                    Go  to Step 8.
Range Level  LESS THAN 67%
[554 adverse      CNMT]
2 Check RCP Status  AT LEAST                  Try to  start  one RCP:
ONE RUNNING
: a. Establish conditions    for starting  RCP.
o  Bus 11A and Bus    llB energized o  Refer to Attachment    RCP START
: b. Start one    RCP. IF no RCP can be started,  THEN go to Step 4.
3 Check IF Normal        PRZR  Spray Available:
: a. Verify IA to    CNMT - AVAILABLE        a. Perform the    following:
: 1) Place PRZR heater control group to PULL STOP.
: 2) Place PRZR heater backup group to OFF.
: 3) Place normal spray valve controllers to  MANUAL at 0%.
: 4) Go  to Step 4.
: b. Go to E-3,    STEAM GENERATOR TUBE RUPTURE,  Step 21
 
    <</ '
ll 4
 
EOP:              TITLE REV    12 ECA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE      CONTROL PAGE 4    of 27 STEP      ACTION/EXPECTED RESPONSE          RESPONSE  NOT OBTAINED 4  Try To Restore        PRZR PORV:
: a. Block valves - AT LEAST    ONE OPEN a. Open one block valve unless      it was  closed to isolate an open
            ~  MOV-516  for PCV-430                PORV.
            ~  MOV-515  for PCV-431C If block valves    can NOT be opened,  THEN dispatch AO to locally ensure breakers to block valves closed.
                                                    ~  MOV-515,  MCC C  position  6C
                                                    ~  MOV-516,  MCC D  position  6C
: b. Check IA to    CNMT - AVAILABLE    b. Refer to Attachment    N2 PORVS  to operate PORVs.
: c. Verify at least one PRZR    PORV    c. Go  to Step 5.
flow path - AVAILABLE
: d. Go  to E-3,  STEAM GENERATOR TUBE RUPTURE,    Step 22
 
J
                    ;r ~
I ~
            ~
              ~
  ~  ~
kf      P~'.
 
EOP:              TITLE:
REV    12 ECA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE            CONTROL PAGE 5    of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED NOTE:    If auxiliary    spray is the only means of RCS pressure control, THEN the  320'F    AT limit between the spray line and PRZR does not apply.
5 Try To Establish Auxiliary Spray:
: a. Charging pumps - AT LEAST    ONE        a. Perform the following:
RUNNING
: 1) IF  CCW  flow is lost to any RCP  thermal barrier OR any RCP  &#xb9;1 seal outlet temperature offscale high, THEN locally isolate seal injection to affected RCP.
                                                            ~ RCP  A, V-300A
                                                            ~ RCP  B, V-300B
: 2) Ensure HCV-142 demand    at  0%.
: 3) Start charging pumps as necessary.
IF charging not available, THEN go    to Step 6.
: b. Establish      auxiliary spray flow:      b. IF  auxiliary spray    can  NOT  be established,    THEN go  to Step 6.
: 1) Open auxiliary spray valve (AOV-296)
: 2) Close charging valve to loop B cold leg (AOV-294)
: c. Go  to E-3,    STEAN GENERATOR TUBE RUPTURE,    Step 21b
 
            / 1
%h      h t
~W    I
~ t  I
~ J'
  ~
:4
 
EOP:             TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER          PRESSURE    CONTROL PAGE 6  of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS  WILL BE NECESSARY (REFER TO ER-AFW.1) ALTERNATE WATER SUPPLY TO AFW PUMPS).
NOTE:   TDAFW pump    flow control valves    fail open  on  loss of IA.
* 6  Monitor Intact        S/G  Level:
: a. Narrow range    level  - GREATER          a. Maintain    total  feed flow greater THAN 5% [25%    adverse  CNMT]                than 200  gpm  until narrow range level greater than 5% [25%
adverse CNMT) in at least one S/G.
: b. Control feed flow to maintain            b. IF narrow range level in intact narrow range level between 17%                S/G continues to increase in an
[25%  adverse  CNMT] and  50%                uncontrolled manner, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.
7  Check PRZR Level  GREATER                    Return to Step    l.
THAN 54    [304 adverse      CNMT]
 
~ 4  A 4
P
 
EOP:            TITLE:
REV: 12 Ec.A-3. 3      SGTR WITHOUT PRESSURIZER  PRESSURE    CONTROL PAGE 7    of 27 STEP      ACTION/EXPECTED RESPONSE          RESPONSE  NOT OBTAINED 8  Check  If SI  Can Be  Terminated:
subcooling based on core                                    Go to
: a. RCS exit  T/Cs - GREATER THAN O' USING FIGURE MIN SUBCOOLING
: a. Do NOT ECA-3 ',stop SI pumps.
SGTR WITH LOSS OF REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.
: b. Secondary heat sink:                b. IF neither condition satisfied, THEN do NOT stop SI pumps. Go o  Total feed flow to  S/Gs          to ECA-3.1, SGTR WITH LOSS OF GREATER THAN 200 GPM AVAILABLE      REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.
                        -OR-o  Narrow range  level in intact S/G - GREATER THAN  5%  [25%
adverse  CNMT]
: c. RVLIS indication                    c. Do NOT  stop SI pumps. Go to ECA-3.1,  SGTR WITH LOSS OF o  Level (no  RCPs) - GREATER          REACTOR COOLANT - SUBCOOLED THAN 68%  [73% adverse CNMT]        RECOVERY DESIRED, Step  l.
                        -OR-o  Fluid fraction (any  RCP running)  - GREATER THAN 80%
: d. Any ruptured S/G narrow range      d. Do NOT  stop SI pumps. Return to level - INCREASING IN AN                Step 2.
UNCONTROLLED MANNER OR OFFSCALE HIGH
 
      ;r I ~ kt l
+>> E
 
~
EOP:            T1TLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER PRESSURE  CONTROL 1
PAGE 8  of 27 STEP    ACTION/EXPECTED RESPONSE      RESPONSE NOT OBTAINED 9  Stop SI Pumps and Place In AUTO
 
~ ~
EOP:            T!TLE:
REV    12 ECA-3.3        SGTR WITHOUT PRESSURIZER    PRESSURE    CONTROL PAGE 9    of 27 STEP      ACTION/EXPECTED RESPONSE            RESPONSE  NOT OBTAINED 10  Check Been If Charging Established:
Flow Has
: a. Charging pumps -    ANY RUNNING      a. Perform the following:
: 1) IF  CCW  flow is lost to any RCP  thermal barrier OR any RCP  &#xb9;1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal injection needle valve(s) to affected  RCP:
                                                        ~ RCP A,  V-300A
                                                        ~ RCP B,  V-300B
: 2) Ensure HCV-142 open, demand at  0%.
: b. Charging    pump suction aligned to  b. Manually align valves as RWST:                                    necessary. IF LCV-112B can  NOT be opened, THEN perform the o  LCV-112B - OPEN                      following:
o  LCV-112C - CLOSED                    1) Verify charging    pump A NOT running and place in  PULL STOP.
: 2) Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging  pump room).
: 3) WHEN  V-358 open,  THEN direct AO  to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).
: c. Start charging pumps as necessary and adjust charging flow to perform the following:
o  Restore    PRZR level o  Maintain    RCS subcooling based on core exit T/Cs - GREATER THAN O'F USING FIGURE MIN SUBCOOLING
 
      ~ I
'4.
I',
4*
4ge I
 
TITLE REV: 12 ECA-3. 3        SGTR WITHOUT PRESSURIZER PRESSURE        CONTROL PAGE 10    of 27 STEP      ACTION/EXPECTED RESPONSE            RESPONSE  NOT OBTAINED
*11 Monitor      RCS  Inventory:              Perform the following:
o  RCS  subcooling based on core        a. Manually operate SI pumps as exit  T/Cs -  GREATER THAN O'            necessary.
USING FIGURE MIN SUBCOOLING
: b. Go to ECA-3.1, SGTR WITH LOSS OF o  RVLIS  indication                      REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.
o  Level (no  RCPs) - GREATER THAN 68%  [73% adv'erse CNMT]
                      -OR-o  Fluid fraction (any    RCP running)  - GREATER THAN 80%
12 Verify Adequate        SW  Flow To CCW  Hx:
: a. Verify at least    two  SW pumps    a. Manually    start pumps as power RUNNING                                  supply permits (258 kw per pump). IF less than two SW pumps can be operated, THEN go to Step 20.
: b. Verify AUX BLDG    SW  isolation    b. Establish SW to AUX BLDG (Refer valves - OPEN                            to Attachment AUX BLDG SW).
        ~ MOV-4615 and MOV-4734
        ~ MOV-4616 and MOV-4735
: c. Verify CNMT RECIRC fan              c. Dispatch AO to locally throttle annunciator C-2, HIGH                    flow to CCW Hx to between TEMPERATURE ALARM    - EXTINGUISHED    5000 gpm and 6000 gpm    total flow.
 
~k 4 4 t[
      ~, gag
 
EOP:            1'I TLE:
REV: 12 ECA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE      CONTROL PAGE 11    of 27 STEP      ACTION/EXPECTED RESPONSE            RESPONSE  NOT OBTAINED 13  Check Operation If Normal        CVCS Can Be Established
: a. Verify IA restored:                  a. Continue with Step 17. WHEN IA restored, THEN do Steps 13 o  IA to      CNMT (AOV-5392) - OPEN    through 16.
o  IA pressure      - GREATER THAN 60 PSIG
: b. Verify instrument bus      D-        b. Energize    MCC  B. IF MCC B NOT ENERGIZED                                available,  THEN  perform the following:
: 1) Verify MCC  A energized.
: 2) Place instrument bus      D on maintenance supply.
: c. CCW  pumps - ANY RUNNING              c. Perform the following:
: 1) IF any  RCP 81 seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected    RCP(s).
                                                        ~ RCP A, MOV-749A    and MOV-759A
                                                        ~ RCP B, MOV-749B    and MOV-759B
: 2) Manually    start  one  CCW pump.
: d. Charging pump -       ANY RUNNING    d. Continue with Step 20.        WHEN  any charging  pump  running,  THEN do Steps 14  through 17.
 
pl 14 l
)\5 4
4,t
 
EOP:            TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER            PRESSURE      CONTROL PAGE 12  of 27 STEP      ACTION/EXPECTED RESPONSE                  RESPONSE  NOT OBTAINED NOTE:  If PRZR  level is less than    13%,  letdown  may be  established by placing AOV-427  to  OPEN.
14  Establish Normal Letdown:                        IF RCP seal return has been established, THEN establish excess
: a. Establish charging    line flow to          letdown as follows:
REGEN Hx - GREATER THAN 20 GPM o  Place excess letdown    divert
: b. Place the following switches to                  valve, AOV-312, to    NORMAL.
CLOSE:
o  Ensure CCW from excess      letdown
          ~ Letdown    orifice valves                      open, (AOV-745).
(AOV-200A, AOV-200B, and AOV-202)                                   o  Open excess    letdown  isolation
          ~ AOV-371, letdown isolation                    valve AOV-310.
valve
          ~ AOV-427, loop    B cold leg to            o  Slowly open HCV-123 to maintain REGEN Hx                                      excess letdown temperature less than 195'F and pressure less
: c. Place letdown controllers in                    than 100 psig.
MANUAL at 40%    open o  Adjust charging    pump speed  as
          ~ TCV-130                                        necessary.
          ~ PCV-135 IF RCP seal return NOT established,
: d. Reset both    trains of  XY  relays          THEN consult TSC to determine        if for  AOV-371 and AOV-427                    excess  letdown should be placed in service.
: e. Open AOV-371 and AOV-427
: f. Open  letdown  orifice valves    as necessary
: g. Place TCV-130    in AUTO at  105  'F
: h. Place PCV-135    in AUTO at  250  psig
: i. Adjust charging    pump speed  and HCV-142 as necessary
 
g' sr, l I F E
 
EOP:             TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER PRESSURE        CONTROL PAGE 13  of 27 STEP      ACTION/EXPECTED RESPONSE          RESPONSE  NOT OBTAINED 15    Check VCT Makeup System:
: a. Adjust boric acid flow control valve in AUTO to 9.5 gpm
: b. Verify the following:                b. Adjust controls as necessary.
: 1) RMW  mode  selector switch in AUTO
: 2) RMW  control    armed - RED LIGHT LIT
: c. Check  VCT  level:                  c. Manually increase    VCT makeup flow as  follows:
o  Level    - GREATER THAN 20%
: 1) Ensure BA  transfer    pumps and
                          -OR-                        RMW  pumps  running. IF NOT, THEN  reset MCC C and MCC D UV o  Level -    STABLE OR INCREASING        lockouts as necessary.
: 2) Place  RMW  flow control valve HCV-111  in  MANUAL.
: 3) Increase  RMW  flow.'
 
p%
A td  ~ -1 k.
Q I' ip
 
EOP:              TITLE:
REV    12 ECA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE      CONTROL PAGE 14  of 27 STEP      ACTION/EXPECTED RESPONSE        RESPONSE NOT OBTAINED 16    Check Charging Pump Suction Aligned  To VCT:
: a. VCT level  - GREATER THAN 20%  a. IF  VCT  level  can NOT  be maintained greater than    5%, THEN perform the following:
: 1) Ensure charging pump suction aligned to  RWST o  LCV-112B open o  LCV-112C  closed
: 2) Continue    with Step 17. WHEN VCT level greater    than 40%,
THEN do Step 16b.
        . b. Verify charging pumps aligned to b. Manually align valves as VCT                                  necessary.
o  LCV-112C - OPEN o  LCV-112B - CLOSED
 
                  ~l ~
~ t/g                  ~ e
          ~ 'I ij4 I
q 'L,>
 
4 ~
EOP:            TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER PRESSURE    CONTROL PAGE 15  of 27 STEP      ACTION/EXPECTED RESPONSE          RESPONSE NOT OBTAINED 17  Check RCP Cooling:                    Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).
: a. Check  CCW to  RCPs:
o  Annunciator A-7,    RCP 1A CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED i
o  Annunciator A-15,    RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED
: b. Check  RCP seal injection:
o  Labyrinth seal D/Ps    - GREATER THAN 15 INCHES OF WATER
                            -OR-o  RCP  seal injection flow to each  RCP  - GREATER THAN 6 GPM
 
r 1
p
        > ~
J I
 
~ ~
EOP:              TITLE:
REV: 12 ECA-P.3          SGTR WITHOUT PRESSURIZER    PRESSURE    CONTROL PAGE 16 of 27 STEP      ACTION/EXPECTED RESPONSE            RESPONSE  NOT OBTAINED 18    Check  If  Seal Return Flow Should Be Established:
: a. Verify RCP &#xb9;1 seal outlet            a. Go to Step 19.
temperature      - LESS THAN 235'F
: b. Verify  RCP  seal outlet valves    b. Manually open valves as OPEN                                    necessary.
                ~ AOV-270A
                ~ AOV-270B
: c. Reset both trains of XY relays for RCP seal return isolation valve  MOV-313
: d. Open  RCP    seal return isolation  d. Perform the    following:
valve  MOV-313
: 1) Place MOV-313 switch to OPEN.
: 2) Dispatch AO with key to RWST gate to locally open MOV-313.
: e. Verify RCP &#xb9;1 seal leakoff flow      e. Perform the following:
LESS THAN    5.5  GPM
: 1) Trip the affected  RCP
: 2) Allow  3 minutes for pump coast down, THEN close the affected RCP seal discharge valve
                                                            . RCP A, AOV-270A
                                                            ~ RCP B, AOV-270B IF both RCP seal discharge valves are shut, THEN go to Step 19.
: f. Verify RCP    &#xb9;1 seal leakoff flow  f. Refer to AP-RCP.1,  RCP SEAL GREATER THAN      0.8  GPM            MALFUNCTION.
 
    ~'1 k
Cp
 
      ~ ~
~ s ~
EOP:              TITLE:
REV: 12 ECA-0.3          SGTR WITHOUT PRESSURIZER      PRESSURE    CONTROL PAGE 17  of 27 STEP      ACTION/EXPECTED RESPONSE              RESPONSE  NOT OBTAINED 19  Equalize Charging And Letdown Flows:
: a. Verify charging      pump controllers in manual
: b. Control charging and seal injection flows to equal letdown and seal    leakoff flows 20    Check    If Emergency Should Be Stopped:
D/Gs
: a. Verify AC    emergency busses          a. Try to restore    offsite power energized by    offsite power:            (Refer to ER-ELEC.1,  RESTORATION OF OFFSITE POWER).
o  Emergency D/G      output breakers OPEN o  AC emergency      bus voltage-GREATER THAN      420 VOLTS o  AC  emergency bus normal feed breakers -    CLOSED
: b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP) 21  Minimize Secondary Syst: em Contamination:
: a. Isolate reject from hotwell to          a. IF hotwell    level increasing, CST'                                        THEN  direct RP to sample hotwells for activity.
Place hotwell level                                K controller    (HC-107) in  MANUAL at  50%
o  Verify hotwell level      - STABLE
: b. Verify local actions to complete isolation of ruptured S/G (Refer to Attachment RUPTURED S/G)
 
        ~ ~
C e9 0
l 1
 
EOP:              TITLE:
REV: 12 ECA-3.3          SGTR WITHOUT PRESSURIZER      PRESSURE    CONTROL PAGE 18    of 27 STEP      ACTION/EXPECTED RESPONSE              RESPONSE NOT OBTAINED NOTE:    Adverse  CNMT conditions or loss of forced air cooling  may  result in failure of  NIS  detectors.
22  Check    If Source Detectors Should Range Be Energized:
: a. Source range channels                  a. Go  to Step 22e.
DEENERGIZED
: b. Check intermediate range      flux-    b. Perform the following:
EITHER CHANNEL LESS THAN 10 10 AMPS                                1) IF  neither intermediate range channel  is decreasing,  THEN initiate boration.
: 2) Continue  with Step 23. WHEN flux is LESS THAN 10-10  ~ps on any operable channel,  THEN do Steps 22c through e.
c..Check the following:                    c. Continue with Step 23.      WHEN either condition met,  THEN do o  Both intermediate range                Steps 22d and e.
channels - LESS THAN 10 10 AMPS
                        -OR-o  Greater than  20  minutes since reactor  trip
: d. Verify source    range detectors      d. Manually energize source range ENERGIZED                                  detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).
IF source ranges can NOT be restored, THEN refer to ER-NIS.1, SR MALFUNCTION and go to Step 22.
: e. Transfer Rk-45 recorder to one source range and one intermediate range channel
 
~ ~
EOP:              TITLE:
REV: 12 EGA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 19  of 27 STEP      ACTION/EXPECTED RESPONSE              RESPONSE  NOT OBTAINED 23    Establish Normal Shutdown Alignment:
: a. Check condenser      - AVAILABLE        a. Dispatch  AO to perform Attachment SD-2.
: b. Perform the following:
o  Open  generator disconnects
                ~  1G13A71
                ~  9X13A73 o  Place voltage regulator to      OFF o  Open    turbine drain valves o  Rotate reheater steam supply controller cern to close valves' Place reheater dump valve switches to HAND o  Stop  all  but  one condensate pump
: c. Verify adequate Rx head cooling:
: 1) Check IA to    CNMT  - AVAILABLE        1)  Go to Step 24.
: 2) Verify at least      one control        2) Manually start one fan as rod shroud fan      - RUNNING                power supply permits (45 kw)
: 3) Verify one    Rx compartment            3) Perform the  following:
cooling    fan - RUNNING o  Dispatch  AO to reset UV relays at  MCC C and MCC D.
o  Manually start one fan as power supply permits (23 kw)
: d. Verify Attachment    SD COMPLETE
 
          )w
        'o
    ~ r I
T
 
EOP:              T!TLE:
REV    12 ECA-3.3          SGTR WITHOUT PRESSURIZER PRESSURE              CONTROL I                                                                      PAGE 20  of 27 STEP      ACTION/EXPECTED RESPONSE                  RESPONSE  NOT OBTAINED NOTE:    Plant staff should decide whether to repair PRZR pressure control systems or continue with this procedure.          If PRZR pressure control is established, PRZR level should be restored to greater than 5% [30%
adverse CNMT] and then further recovery should continue with E-3, STEAM GENERATOR TUBE RUPTURE,        Step 37.
24    Check Isolated:
If SI    ACCUMs  Should Be
: a. Check the following:                        a. Return to Step 11.
o  RCS  subcooling based on core exit  T/Cs -  GREATER THAN O' USING FIGURE MIN SUBCOOLING o  RVLIS    indication  - GREATER THAN 68%    [73%  adverse  CNMT]
: b. Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves
            ~ MOV-841,    MCC C position  12F
            ~ MOV-865,    MCC D  position  12C
: c. Close SI    ACCUM discharge valves          c. Vent any unisolated  ACCUMs:
            ~ MOV-841                                      1) Open vent valves  for
            ~ MOV-865                                          unisolated SI  ACCUMs.
                                                                ~ ACCUM A, AOV-834A
                                                                ~ ACCUM B, AOV-834B
: 2) Open HCV-945.
: d. Locally reopen breakers for MOV-841 and MOV-865
 
Ig CS It Ifti
!p
 
EOP:            TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER        PRESSURE    CONTROL PAGE 21  of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED NOTE:  Leakage from ruptured S/G      into RCS will dilute  RCS  boron concentration.
25  Verify Adequate        Shutdown Margin
: a. Direct  RP to sample RCS and ruptured S/G for boron concentration
: b. Verify boron concentration-              b. Borate as necessary.
GREATER THAN REQUIREMENTS OF FIGURE SDM 26  Maintain Required        RCP Seal            Perform the following:
Injection      Flow And Labyrinth Seal D/P:                                    o  Adjust charging flow to    REGEN Hx, HCV-142 as necessary.
o  Labyrinth seal    D/P to each RCP-GREATER THAN 15 INCHES, OF WATER                        -OR-o  RCP seal    injection flow-              o  Dispatch  AO  to adjust seal GREATER THAN 6 GPM                            injection needle valves    V-300A and V-300B  if necessary.
27  Initiate    RCS  Cooldown  to 350'F In    RCS  Cold Legs:
: a. Establish and maintain cooldown rate in  RCS  cold legs - LESS THAN  100'F/HR
: b. Dump  steam to condenser    from          b. Manually or locally dump steam intact  S/G                                  using intact S/G ARV.
IF  no intact  S/G available, THEN use  faulted  S/G.
 
~ ~
EOP:              TITLE:
REV: 12 EGA-).3          SGTR WITHOUT PRESSURIZER      PRESSURE    CONTROL PAGE 22 of 27 STEP      ACTION/EXPECTED RESPONSE              RESPONSE  NOT OBTAINED CAUTION RCS AND RUPTURED S/G PRESSURES  MUST BE MAINTAINED LESS THAN THE RUPTURED S/G ARV SETPOINT.
28    Control Charging Flow To Maintain RCS Subcooling:
: a. RCS  subcooling based on core          a. Increase charging flow to exit T/Cs - GREATER THAN 20'F              maintain subcooling greater than USING FIGURE MIN SUBCOOLING                20'F using Figure MIN SUBCOOLING and go to Step 29.
: b. Ruptured S/G narrow range level        b. Control charging flow to LESS THAN 90% [85% adverse                maintain RCS pressure at CNMT]                                       ruptured S/G pressure and go to Step 29.
: c. Ruptured S/G narrow range level        c. IF ruptured S/G level STABLE OR DECREASING                      increasing,  THEN decrease charging flow to stabilize level. Maintain RCS subcooling greater than 20'F using Figure MIN SUBCOOLING.
29    Check Be If RCS Stopped:
Cooldown Should
: a. RCS  cold leg temperatures  - LESS    a. Return to Step 25.
THAN  350'F
: b. Stop  RCS    cooldown
 
'I tgl A+
 
EOP:            TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER PRESSURE      CONTROL PAGE 23    of 27 STEP      ACTION/EXPECTED RESPONSE        RESPONSE NOT OBTAINED 30    Check  RCS  Pressure    GREATER  Go  to Step  33 THAN 400 PSIG      [300 PSIG adverse CNMT]
                                                              '31 Monitor Ruptured S/G Narrow          Refill ruptured        S/G to 67% [55%
Range Level  GREATER THAN          adverse    CNMT]    using feed flow.
17%  r25%  adverse  CNMT]
IF either of the following conditions occurs, THEN stop feed flow to ruptured S/G:
o  Ruptured S/G pressure decreases in an  uncontrolled manner.
                                                            -OR-o  Ruptured S/G pressure        increases to 1020 psig.
e
 
~ I EOP:            TITLE REV    12 ECA-3.3        SGTR WITHOUT PRESSURIZER          PRESSURE    CONTROL PAGE 24    of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE  NOT OBTAINED CAUTION o  STEAM SHOULD NOT BE RELEASED FROM A RUPTURED S/G        IF WATER MAY  EXIST IN ITS STEAMLINE.
o  RUPTURED S/G PRESSURE      MAY DECREASE RAPIDLY WHEN STEAM  IS RELEASED.
NOTE:  The upper head      region may void during RCS depressurization    if  RCPs level.
are not running.      This may result in a rapidly increasing    PRZR 32  Depressurize RCS And Ruptured S/G To 400 PSIG t'300 PSIG adverse    CNMT]
: a. Perform the following:
o  Decrease    charging and increase letdown to initiate backfill
                          -OR-o  Initiate    blowdown from ruptured    S/G
                          -OR-o  Dump  steam from ruptured S/G
: b. Check  RCS  pressure  - LESS THAN      b. ReturTL to Step 31.
400  psig [300 psig adverse      CNMT]
: c. Stop  RCS  depressurization
 
1 I 'p
'bl"g I
        >as 0
 
EOP:            TITLE:
REV: 12 ECA-3.3        SGTR WITHOUT PRESSURIZER          PRESSURE      CONTROL I
PAGE 25  of 27 STEP      ACTION/EXPECTED RESPONSE                RESPONSE NOT OBTAINED 33  Check Can Be IfEstablished:
RHR Normal    Cooling
: a. RCS  cold leg temperature    - LESS      a. Return to Step 27.
THAN  350'F
: b. RCS  pressure    - LESS THAN              b. Return to Step 31.
400  psig [300 psig adverse    CNMT]
: c. Place  RCS  overpressure                  c. IF  RCS  overpressure  protection protection system in service                  system can    NOT be placed in (Refer to 0-7, ALIGNMENT AND                  service,  THEN  notify TSC of OPERATION OF THE REACTOR VESSEL                potential    Tech Spec violation if OVERPRESSURE PROTECTION SYSTEM)                RHR  system  is placed in service.
: d. Establish    RHR  normal cooling (Refer to Attachment      RHR COOL)
NOTE:  Leakage from ruptured S/G      into  RCS will dilute    RCS  boron concentration.
34  Verify Adequate        Shutdown Margin
: a. Direct  RP to sample RCS and ruptured S/G for boron concentration
: b. Verify boron concentration-                b. Borate as necessary.
GREATER THAN REQUIREMENTS OF FIGURE SDM
 
1 4
I 7'
 
EOP:             TITLE:
REV: 12 ECA-3.3         SGTR WITHOUT PRESSURIZER  PRESSURE      CONTROL PAGE 26  of 27 STEP      ACTION/EXPECTED RESPONSE        RESPONSE  NOT OBTAINED 35  Initiate    RCS  Cooldown To Cold Shutdown:
: a. Establish and maintain cooldown rate in    RCS  cold legs  - LESS THAN  100'F/HR
: b. Use  RHR  system  if in service
: c. Dump  steam to condenser    from  c. Manually or locally dump steam intact  S/G                          from intact S/G using ARVs.
IF  no intact  S/G  available and RHR  system  NOT  in service, THEN use  faulted  S/G.
36  Control Charging Flow To Maintain RCS Subcooling:
: a. RCS  subcooling based on core      a. Increase charging flow to exit  T/Cs - GREATER THAN 20'F        maintain subcooling greater than USING FIGURE MIN SUBCOOLING            20'F using Figure MIN SUBCOOLING and go to Step 37.
: b. Ruptured S/G narrow range level    b. Control charging flow to LESS THAN 90%    [85%  adverse      maintain RCS pressure at CNMT)                                  ruptured S/G pressure and go to Step 37.
: c. Ruptured S/G narrow range level    c. IF ruptured S/G level STABLE OR DECREASING                increasing, THEN decrease charging flow to stabilize level. Maintain RCS subcooling greater than 20'F using Figure MIN SUBCOOLING  ~
 
Ig '.
      \ I
 
EOP:            T1TLE:
REV: 12 ECA-,3. 3      SGTR WITHOUT PRESSURIZER PRESSURE          CONTROL I
PAGE 27 of 27 STEP      ACTION/EXPECTED RESPONSE              RESPONSE NOT OBTAINED
  *37  Monitor    RCP  Operation:
: a. RCPs  - ANY RUNNING                    a. Go to Step 39.
: b. Check the following:                  b. Stop the affected RCP(s).
o  RCP &#xb9;1 seal D/P - GREATER THAN 220 PSID o  Check RCP seal leakage WITHIN THE NORMAL OPERATING RANGE OF FIGURE RCP SEAL LEAKOFF 38  Check Core      Exit T/Cs  LESS          Return to Step 34.
THAN  200'F 39  Evaluate Long Term Plant Status:
: a. Maintain cold shutdown conditions
: b. Consult  TSC
                                            -END-
 
EOP:        TITLE:
REV: 12 ECA-3. 3    SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 1  of 1 ECA-3.3 APPENDIX LIST TITLE                                PAGES
: 1) RED PATH
 
==SUMMARY==
: 2) FIGURE MIN SUBCOOLING
: 3) FIGURE SDM
: 4) FIGURE RCP SEAL LEAKOFF
: 5) ATTACHMENT RCP START
: 6) ATTACHMENT N2 PORVS
: 7) ATTACHMENT RUPTURED S/G
: 8) ATTACHMENT D/G STOP
: 9) ATTACHMENT SD-1
: 10)  ATTACHMENT SEAL COOLING
: 11)  ATTACHMENT SD-2
: 12)  ATTACHMENT RHR COOL
: 13)  ATTACHMENT AUX BLDG SW
: 14)  FOLDOUT
 
J f
 
EOP:        TITLE:
REV  12
  ,ECA-~.3    SGTR WITHOUT PRESSURIZER PRESSURE    CONTROL PAGE 1  of 1 RED PATH
 
==SUMMARY==
: a. SUBCRITICALITY  Nuclear power    greater than 5t
: b. CORE COOLING  Core exit T/Cs greater than 1200'F
                                          -OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs) less than 434 [464 adverse  CNMT]
: c. HEAT SINK  Narrow  range  level in all  S/Gs  less than 54
[254 adverse  CNMT] AND  total  feedwater flow less than  200 gpm
: d. INTEGRITY  Cold leg temperatures decrease greater        than 100 F in last 60 minutes AND RCS cold      leg temperature less than 285'F
: e. CONTAINMENT  CNMT pressure greater than      60  psig
 
0 ~
f r>,(
J lO pl/
h
 
EOP:                TITLE:
REV: 12 ECA-3.3            SGTR WITHOUT PRESSURIZER      PRESSURE  CONTROL
          ~z  ~ ~
PAGE 1  of  1 FIGURE MIN SUBCOOLING NOTE:       Subcooling Margin = Saturation Temperature From Figure Below  [-] Core Exit  T/C  Indication RC S    PRESSURE  (PSIG) 2500 2400 RCS PRESSURE 2300 INCREMENTS 20 PSIG 2200 2100 2000 1900 1800 1700 1600 1500 SUBCOOLED 1300                              REGION 1200 1100 1000 900 800 INADEQUATE 700                                                                  SUBCOOLING
'00          ADVERSE CNMT REGION 500 400 300 200                                            NORMAL CNMT                  TEMPERATURE INCREMENTS 10'F 100 0
200          250      300    350    400    450    500    550      600    650    700 CORE EXIT SATURATION TEMPERATURE ('F)
 
    ~ ~ qs l.'
V 4
 
EOP:             TITLE REV  12 EGA,-3 ~ 3      SGTR WITHOUT PRESSURIZER    PRESSURE    CONTROL PAGE 1  of  1 FIGURE SDM NOTE:     o Curve includes allowance for one stuck rod. Add 100 ppm for each additional stuck rod.
o To obtain core burnup, use PPCS point ID BURNUP.
BORON CONCENTRATION (PPM) 1800 BORON INCREMENTS 20 PPH 1600 1400 ADEQUATE SDH 1200                                                      100 PPH CONSERVATISH INCLUDED 1000 800 600 400 200                                                                      BURNUP INCREMENTS 100 MWD/MTU 0  1000    2000  3000 4000  5000  6000  7000  8000  9000 10000 11000  12000 CYCLE 25 BURNUP (MWD/MTU)
 
I'         i 0
        ~
  ~ 't C
a~ 'l (A
f~<
4( j
 
EOP:             TITLE:
REV: 12 ECA-3.3         SGTR WITHOUT PRESSURIZER      PRESSURE  CONTROL
    ~ r PAGE 1    of  1 FIGURE RCP SEAL LEAKOFF
&#xb9;1 SEAL LEAK    RATE (GPH) 6 LEAK RATE INCREHENTS 0.2 GPH NORHAL OPERATING RANGE DP INCREHENTS 50  PSI 250      500    750    1000  1250    1500    1750    2000    2250      2500
                          &#xb9;1  SEAL DP (RCS PRESS - VCT PRESS) PSI
 
    ~e W~'}}

Latest revision as of 04:27, 4 February 2020

Rev 12 to EOP ECA-3.3, SGTR W/O Pressurizer Pressure Control.
ML17309A576
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/20/1995
From: Marlow T
ROCHESTER GAS & ELECTRIC CORP.
To:
References
ECA-3.3, NUDOCS 9504280026
Download: ML17309A576 (64)


Text

EOP: T1TLE:

REV: 12 ECA-).3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 1 of 27 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE W /'7 PLANT S PERINTE DENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

QO'.

9504280026 950420 PDR ADOCK 05000244 P PDR I

~ J v

V h

EOP: TITLE REV: 12 ECA-3. 9 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL I I PAGE 2 of 27 A. PURPOSE This procedure provides actions for a SGTR with coincident loss of normal and auxiliary PRZR sprays and PORVs.

B. ENTRY CONDITIONS/SYMPTOMS

1. ENTRY CONDITIONS This procedure is entered from:
a. E-3, STEAM GENERATOR TUBE RUPTURE, when PRZR pressure control is not available.

V EOP: TITLE:

REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 3 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: o Foldout page should be open AND monitored periodically.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+ 5 R/hr.

1 Check Ruptured S/G Narrow Go to Step 8.

Range Level LESS THAN 67%

[554 adverse CNMT]

2 Check RCP Status AT LEAST Try to start one RCP:

ONE RUNNING

a. Establish conditions for starting RCP.

o Bus 11A and Bus llB energized o Refer to Attachment RCP START

b. Start one RCP. IF no RCP can be started, THEN go to Step 4.

3 Check IF Normal PRZR Spray Available:

a. Verify IA to CNMT - AVAILABLE a. Perform the following:
1) Place PRZR heater control group to PULL STOP.
2) Place PRZR heater backup group to OFF.
3) Place normal spray valve controllers to MANUAL at 0%.
4) Go to Step 4.
b. Go to E-3, STEAM GENERATOR TUBE RUPTURE, Step 21

<</ '

ll 4

EOP: TITLE REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 4 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 4 Try To Restore PRZR PORV:

a. Block valves - AT LEAST ONE OPEN a. Open one block valve unless it was closed to isolate an open

~ MOV-516 for PCV-430 PORV.

~ MOV-515 for PCV-431C If block valves can NOT be opened, THEN dispatch AO to locally ensure breakers to block valves closed.

~ MOV-515, MCC C position 6C

~ MOV-516, MCC D position 6C

b. Check IA to CNMT - AVAILABLE b. Refer to Attachment N2 PORVS to operate PORVs.
c. Verify at least one PRZR PORV c. Go to Step 5.

flow path - AVAILABLE

d. Go to E-3, STEAM GENERATOR TUBE RUPTURE, Step 22

J

r ~

I ~

~

~

~ ~

kf P~'.

EOP: TITLE:

REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 5 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If auxiliary spray is the only means of RCS pressure control, THEN the 320'F AT limit between the spray line and PRZR does not apply.

5 Try To Establish Auxiliary Spray:

a. Charging pumps - AT LEAST ONE a. Perform the following:

RUNNING

1) IF CCW flow is lost to any RCP thermal barrier OR any RCP ¹1 seal outlet temperature offscale high, THEN locally isolate seal injection to affected RCP.

~ RCP A, V-300A

~ RCP B, V-300B

2) Ensure HCV-142 demand at 0%.
3) Start charging pumps as necessary.

IF charging not available, THEN go to Step 6.

b. Establish auxiliary spray flow: b. IF auxiliary spray can NOT be established, THEN go to Step 6.
1) Open auxiliary spray valve (AOV-296)
2) Close charging valve to loop B cold leg (AOV-294)
c. Go to E-3, STEAN GENERATOR TUBE RUPTURE, Step 21b

/ 1

%h h t

~W I

~ t I

~ J'

~

4

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 6 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1) ALTERNATE WATER SUPPLY TO AFW PUMPS).

NOTE: TDAFW pump flow control valves fail open on loss of IA.

  • 6 Monitor Intact S/G Level:
a. Narrow range level - GREATER a. Maintain total feed flow greater THAN 5% [25% adverse CNMT] than 200 gpm until narrow range level greater than 5% [25%

adverse CNMT) in at least one S/G.

b. Control feed flow to maintain b. IF narrow range level in intact narrow range level between 17% S/G continues to increase in an

[25% adverse CNMT] and 50% uncontrolled manner, THEN go to ECA-3.1, SGTR WITH LOSS OF REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.

7 Check PRZR Level GREATER Return to Step l.

THAN 54 [304 adverse CNMT]

~ 4 A 4

P

EOP: TITLE:

REV: 12 Ec.A-3. 3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 7 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 8 Check If SI Can Be Terminated:

subcooling based on core Go to

a. RCS exit T/Cs - GREATER THAN O' USING FIGURE MIN SUBCOOLING
a. Do NOT ECA-3 ',stop SI pumps.

SGTR WITH LOSS OF REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.

b. Secondary heat sink: b. IF neither condition satisfied, THEN do NOT stop SI pumps. Go o Total feed flow to S/Gs to ECA-3.1, SGTR WITH LOSS OF GREATER THAN 200 GPM AVAILABLE REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.

-OR-o Narrow range level in intact S/G - GREATER THAN 5% [25%

adverse CNMT]

c. RVLIS indication c. Do NOT stop SI pumps. Go to ECA-3.1, SGTR WITH LOSS OF o Level (no RCPs) - GREATER REACTOR COOLANT - SUBCOOLED THAN 68% [73% adverse CNMT] RECOVERY DESIRED, Step l.

-OR-o Fluid fraction (any RCP running) - GREATER THAN 80%

d. Any ruptured S/G narrow range d. Do NOT stop SI pumps. Return to level - INCREASING IN AN Step 2.

UNCONTROLLED MANNER OR OFFSCALE HIGH

r I ~ kt l

+>> E

~

EOP: T1TLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL 1

PAGE 8 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 9 Stop SI Pumps and Place In AUTO

~ ~

EOP: T!TLE:

REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 9 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 10 Check Been If Charging Established:

Flow Has

a. Charging pumps - ANY RUNNING a. Perform the following:
1) IF CCW flow is lost to any RCP thermal barrier OR any RCP ¹1 seal outlet temperature offscale high, THEN dispatch AO with key to RWST gate to close seal injection needle valve(s) to affected RCP:

~ RCP A, V-300A

~ RCP B, V-300B

2) Ensure HCV-142 open, demand at 0%.
b. Charging pump suction aligned to b. Manually align valves as RWST: necessary. IF LCV-112B can NOT be opened, THEN perform the o LCV-112B - OPEN following:

o LCV-112C - CLOSED 1) Verify charging pump A NOT running and place in PULL STOP.

2) Dispatch AO to locally open manual charging pump suction from RWST (V-358 located in charging pump room).
3) WHEN V-358 open, THEN direct AO to close V-268 to isolate charging pumps B and C from VCT (V-268 located in charging pump room).
c. Start charging pumps as necessary and adjust charging flow to perform the following:

o Restore PRZR level o Maintain RCS subcooling based on core exit T/Cs - GREATER THAN O'F USING FIGURE MIN SUBCOOLING

~ I

'4.

I',

4*

4ge I

TITLE REV: 12 ECA-3. 3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 10 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

  • 11 Monitor RCS Inventory: Perform the following:

o RCS subcooling based on core a. Manually operate SI pumps as exit T/Cs - GREATER THAN O' necessary.

USING FIGURE MIN SUBCOOLING

b. Go to ECA-3.1, SGTR WITH LOSS OF o RVLIS indication REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED, Step 1.

o Level (no RCPs) - GREATER THAN 68% [73% adv'erse CNMT]

-OR-o Fluid fraction (any RCP running) - GREATER THAN 80%

12 Verify Adequate SW Flow To CCW Hx:

a. Verify at least two SW pumps a. Manually start pumps as power RUNNING supply permits (258 kw per pump). IF less than two SW pumps can be operated, THEN go to Step 20.
b. Verify AUX BLDG SW isolation b. Establish SW to AUX BLDG (Refer valves - OPEN to Attachment AUX BLDG SW).

~ MOV-4615 and MOV-4734

~ MOV-4616 and MOV-4735

c. Verify CNMT RECIRC fan c. Dispatch AO to locally throttle annunciator C-2, HIGH flow to CCW Hx to between TEMPERATURE ALARM - EXTINGUISHED 5000 gpm and 6000 gpm total flow.

~k 4 4 t[

~, gag

EOP: 1'I TLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 11 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 13 Check Operation If Normal CVCS Can Be Established

a. Verify IA restored: a. Continue with Step 17. WHEN IA restored, THEN do Steps 13 o IA to CNMT (AOV-5392) - OPEN through 16.

o IA pressure - GREATER THAN 60 PSIG

b. Verify instrument bus D- b. Energize MCC B. IF MCC B NOT ENERGIZED available, THEN perform the following:
1) Verify MCC A energized.
2) Place instrument bus D on maintenance supply.
c. CCW pumps - ANY RUNNING c. Perform the following:
1) IF any RCP 81 seal outlet temperature offscale high, THEN isolate CCW to thermal barrier of affected RCP(s).

~ RCP A, MOV-749A and MOV-759A

~ RCP B, MOV-749B and MOV-759B

2) Manually start one CCW pump.
d. Charging pump - ANY RUNNING d. Continue with Step 20. WHEN any charging pump running, THEN do Steps 14 through 17.

pl 14 l

)\5 4

4,t

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 12 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: If PRZR level is less than 13%, letdown may be established by placing AOV-427 to OPEN.

14 Establish Normal Letdown: IF RCP seal return has been established, THEN establish excess

a. Establish charging line flow to letdown as follows:

REGEN Hx - GREATER THAN 20 GPM o Place excess letdown divert

b. Place the following switches to valve, AOV-312, to NORMAL.

CLOSE:

o Ensure CCW from excess letdown

~ Letdown orifice valves open, (AOV-745).

(AOV-200A, AOV-200B, and AOV-202) o Open excess letdown isolation

~ AOV-371, letdown isolation valve AOV-310.

valve

~ AOV-427, loop B cold leg to o Slowly open HCV-123 to maintain REGEN Hx excess letdown temperature less than 195'F and pressure less

c. Place letdown controllers in than 100 psig.

MANUAL at 40% open o Adjust charging pump speed as

~ TCV-130 necessary.

~ PCV-135 IF RCP seal return NOT established,

d. Reset both trains of XY relays THEN consult TSC to determine if for AOV-371 and AOV-427 excess letdown should be placed in service.
e. Open AOV-371 and AOV-427
f. Open letdown orifice valves as necessary
g. Place TCV-130 in AUTO at 105 'F
h. Place PCV-135 in AUTO at 250 psig
i. Adjust charging pump speed and HCV-142 as necessary

g' sr, l I F E

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 13 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 15 Check VCT Makeup System:

a. Adjust boric acid flow control valve in AUTO to 9.5 gpm
b. Verify the following: b. Adjust controls as necessary.
1) RMW mode selector switch in AUTO
2) RMW control armed - RED LIGHT LIT
c. Check VCT level: c. Manually increase VCT makeup flow as follows:

o Level - GREATER THAN 20%

1) Ensure BA transfer pumps and

-OR- RMW pumps running. IF NOT, THEN reset MCC C and MCC D UV o Level - STABLE OR INCREASING lockouts as necessary.

2) Place RMW flow control valve HCV-111 in MANUAL.
3) Increase RMW flow.'

p%

A td ~ -1 k.

Q I' ip

EOP: TITLE:

REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 14 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 16 Check Charging Pump Suction Aligned To VCT:

a. VCT level - GREATER THAN 20% a. IF VCT level can NOT be maintained greater than 5%, THEN perform the following:
1) Ensure charging pump suction aligned to RWST o LCV-112B open o LCV-112C closed
2) Continue with Step 17. WHEN VCT level greater than 40%,

THEN do Step 16b.

. b. Verify charging pumps aligned to b. Manually align valves as VCT necessary.

o LCV-112C - OPEN o LCV-112B - CLOSED

~l ~

~ t/g ~ e

~ 'I ij4 I

q 'L,>

4 ~

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 15 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check RCP Cooling: Establish normal cooling to RCPs (Refer to Attachment SEAL COOLING).

a. Check CCW to RCPs:

o Annunciator A-7, RCP 1A CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED i

o Annunciator A-15, RCP 1B CCW RETURN HIGH TEMP OR LOW FLOW EXTINGUISHED

b. Check RCP seal injection:

o Labyrinth seal D/Ps - GREATER THAN 15 INCHES OF WATER

-OR-o RCP seal injection flow to each RCP - GREATER THAN 6 GPM

r 1

p

> ~

J I

~ ~

EOP: TITLE:

REV: 12 ECA-P.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 16 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Check If Seal Return Flow Should Be Established:

a. Verify RCP ¹1 seal outlet a. Go to Step 19.

temperature - LESS THAN 235'F

b. Verify RCP seal outlet valves b. Manually open valves as OPEN necessary.

~ AOV-270A

~ AOV-270B

c. Reset both trains of XY relays for RCP seal return isolation valve MOV-313
d. Open RCP seal return isolation d. Perform the following:

valve MOV-313

1) Place MOV-313 switch to OPEN.
2) Dispatch AO with key to RWST gate to locally open MOV-313.
e. Verify RCP ¹1 seal leakoff flow e. Perform the following:

LESS THAN 5.5 GPM

1) Trip the affected RCP
2) Allow 3 minutes for pump coast down, THEN close the affected RCP seal discharge valve

. RCP A, AOV-270A

~ RCP B, AOV-270B IF both RCP seal discharge valves are shut, THEN go to Step 19.

f. Verify RCP ¹1 seal leakoff flow f. Refer to AP-RCP.1, RCP SEAL GREATER THAN 0.8 GPM MALFUNCTION.

~'1 k

Cp

~ ~

~ s ~

EOP: TITLE:

REV: 12 ECA-0.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 17 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 19 Equalize Charging And Letdown Flows:

a. Verify charging pump controllers in manual
b. Control charging and seal injection flows to equal letdown and seal leakoff flows 20 Check If Emergency Should Be Stopped:

D/Gs

a. Verify AC emergency busses a. Try to restore offsite power energized by offsite power: (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).

o Emergency D/G output breakers OPEN o AC emergency bus voltage-GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers - CLOSED

b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP) 21 Minimize Secondary Syst: em Contamination:
a. Isolate reject from hotwell to a. IF hotwell level increasing, CST' THEN direct RP to sample hotwells for activity.

Place hotwell level K controller (HC-107) in MANUAL at 50%

o Verify hotwell level - STABLE

b. Verify local actions to complete isolation of ruptured S/G (Refer to Attachment RUPTURED S/G)

~ ~

C e9 0

l 1

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 18 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Adverse CNMT conditions or loss of forced air cooling may result in failure of NIS detectors.

22 Check If Source Detectors Should Range Be Energized:

a. Source range channels a. Go to Step 22e.

DEENERGIZED

b. Check intermediate range flux- b. Perform the following:

EITHER CHANNEL LESS THAN 10 10 AMPS 1) IF neither intermediate range channel is decreasing, THEN initiate boration.

2) Continue with Step 23. WHEN flux is LESS THAN 10-10 ~ps on any operable channel, THEN do Steps 22c through e.

c..Check the following: c. Continue with Step 23. WHEN either condition met, THEN do o Both intermediate range Steps 22d and e.

channels - LESS THAN 10 10 AMPS

-OR-o Greater than 20 minutes since reactor trip

d. Verify source range detectors d. Manually energize source range ENERGIZED detectors by depressing P-6 permissive defeat pushbuttons (2 of 2).

IF source ranges can NOT be restored, THEN refer to ER-NIS.1, SR MALFUNCTION and go to Step 22.

e. Transfer Rk-45 recorder to one source range and one intermediate range channel

~ ~

EOP: TITLE:

REV: 12 EGA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 19 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 23 Establish Normal Shutdown Alignment:

a. Check condenser - AVAILABLE a. Dispatch AO to perform Attachment SD-2.
b. Perform the following:

o Open generator disconnects

~ 1G13A71

~ 9X13A73 o Place voltage regulator to OFF o Open turbine drain valves o Rotate reheater steam supply controller cern to close valves' Place reheater dump valve switches to HAND o Stop all but one condensate pump

c. Verify adequate Rx head cooling:
1) Check IA to CNMT - AVAILABLE 1) Go to Step 24.
2) Verify at least one control 2) Manually start one fan as rod shroud fan - RUNNING power supply permits (45 kw)
3) Verify one Rx compartment 3) Perform the following:

cooling fan - RUNNING o Dispatch AO to reset UV relays at MCC C and MCC D.

o Manually start one fan as power supply permits (23 kw)

d. Verify Attachment SD COMPLETE

)w

'o

~ r I

T

EOP: T!TLE:

REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL I PAGE 20 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Plant staff should decide whether to repair PRZR pressure control systems or continue with this procedure. If PRZR pressure control is established, PRZR level should be restored to greater than 5% [30%

adverse CNMT] and then further recovery should continue with E-3, STEAM GENERATOR TUBE RUPTURE, Step 37.

24 Check Isolated:

If SI ACCUMs Should Be

a. Check the following: a. Return to Step 11.

o RCS subcooling based on core exit T/Cs - GREATER THAN O' USING FIGURE MIN SUBCOOLING o RVLIS indication - GREATER THAN 68% [73% adverse CNMT]

b. Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves

~ MOV-841, MCC C position 12F

~ MOV-865, MCC D position 12C

c. Close SI ACCUM discharge valves c. Vent any unisolated ACCUMs:

~ MOV-841 1) Open vent valves for

~ MOV-865 unisolated SI ACCUMs.

~ ACCUM A, AOV-834A

~ ACCUM B, AOV-834B

2) Open HCV-945.
d. Locally reopen breakers for MOV-841 and MOV-865

Ig CS It Ifti

!p

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 21 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE: Leakage from ruptured S/G into RCS will dilute RCS boron concentration.

25 Verify Adequate Shutdown Margin

a. Direct RP to sample RCS and ruptured S/G for boron concentration
b. Verify boron concentration- b. Borate as necessary.

GREATER THAN REQUIREMENTS OF FIGURE SDM 26 Maintain Required RCP Seal Perform the following:

Injection Flow And Labyrinth Seal D/P: o Adjust charging flow to REGEN Hx, HCV-142 as necessary.

o Labyrinth seal D/P to each RCP-GREATER THAN 15 INCHES, OF WATER -OR-o RCP seal injection flow- o Dispatch AO to adjust seal GREATER THAN 6 GPM injection needle valves V-300A and V-300B if necessary.

27 Initiate RCS Cooldown to 350'F In RCS Cold Legs:

a. Establish and maintain cooldown rate in RCS cold legs - LESS THAN 100'F/HR
b. Dump steam to condenser from b. Manually or locally dump steam intact S/G using intact S/G ARV.

IF no intact S/G available, THEN use faulted S/G.

~ ~

EOP: TITLE:

REV: 12 EGA-).3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 22 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION RCS AND RUPTURED S/G PRESSURES MUST BE MAINTAINED LESS THAN THE RUPTURED S/G ARV SETPOINT.

28 Control Charging Flow To Maintain RCS Subcooling:

a. RCS subcooling based on core a. Increase charging flow to exit T/Cs - GREATER THAN 20'F maintain subcooling greater than USING FIGURE MIN SUBCOOLING 20'F using Figure MIN SUBCOOLING and go to Step 29.
b. Ruptured S/G narrow range level b. Control charging flow to LESS THAN 90% [85% adverse maintain RCS pressure at CNMT] ruptured S/G pressure and go to Step 29.
c. Ruptured S/G narrow range level c. IF ruptured S/G level STABLE OR DECREASING increasing, THEN decrease charging flow to stabilize level. Maintain RCS subcooling greater than 20'F using Figure MIN SUBCOOLING.

29 Check Be If RCS Stopped:

Cooldown Should

a. RCS cold leg temperatures - LESS a. Return to Step 25.

THAN 350'F

b. Stop RCS cooldown

'I tgl A+

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 23 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 30 Check RCS Pressure GREATER Go to Step 33 THAN 400 PSIG [300 PSIG adverse CNMT]

'31 Monitor Ruptured S/G Narrow Refill ruptured S/G to 67% [55%

Range Level GREATER THAN adverse CNMT] using feed flow.

17% r25% adverse CNMT]

IF either of the following conditions occurs, THEN stop feed flow to ruptured S/G:

o Ruptured S/G pressure decreases in an uncontrolled manner.

-OR-o Ruptured S/G pressure increases to 1020 psig.

e

~ I EOP: TITLE REV 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 24 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION o STEAM SHOULD NOT BE RELEASED FROM A RUPTURED S/G IF WATER MAY EXIST IN ITS STEAMLINE.

o RUPTURED S/G PRESSURE MAY DECREASE RAPIDLY WHEN STEAM IS RELEASED.

NOTE: The upper head region may void during RCS depressurization if RCPs level.

are not running. This may result in a rapidly increasing PRZR 32 Depressurize RCS And Ruptured S/G To 400 PSIG t'300 PSIG adverse CNMT]

a. Perform the following:

o Decrease charging and increase letdown to initiate backfill

-OR-o Initiate blowdown from ruptured S/G

-OR-o Dump steam from ruptured S/G

b. Check RCS pressure - LESS THAN b. ReturTL to Step 31.

400 psig [300 psig adverse CNMT]

c. Stop RCS depressurization

1 I 'p

'bl"g I

>as 0

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL I

PAGE 25 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 33 Check Can Be IfEstablished:

RHR Normal Cooling

a. RCS cold leg temperature - LESS a. Return to Step 27.

THAN 350'F

b. RCS pressure - LESS THAN b. Return to Step 31.

400 psig [300 psig adverse CNMT]

c. Place RCS overpressure c. IF RCS overpressure protection protection system in service system can NOT be placed in (Refer to 0-7, ALIGNMENT AND service, THEN notify TSC of OPERATION OF THE REACTOR VESSEL potential Tech Spec violation if OVERPRESSURE PROTECTION SYSTEM) RHR system is placed in service.
d. Establish RHR normal cooling (Refer to Attachment RHR COOL)

NOTE: Leakage from ruptured S/G into RCS will dilute RCS boron concentration.

34 Verify Adequate Shutdown Margin

a. Direct RP to sample RCS and ruptured S/G for boron concentration
b. Verify boron concentration- b. Borate as necessary.

GREATER THAN REQUIREMENTS OF FIGURE SDM

1 4

I 7'

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 26 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 35 Initiate RCS Cooldown To Cold Shutdown:

a. Establish and maintain cooldown rate in RCS cold legs - LESS THAN 100'F/HR
b. Use RHR system if in service
c. Dump steam to condenser from c. Manually or locally dump steam intact S/G from intact S/G using ARVs.

IF no intact S/G available and RHR system NOT in service, THEN use faulted S/G.

36 Control Charging Flow To Maintain RCS Subcooling:

a. RCS subcooling based on core a. Increase charging flow to exit T/Cs - GREATER THAN 20'F maintain subcooling greater than USING FIGURE MIN SUBCOOLING 20'F using Figure MIN SUBCOOLING and go to Step 37.
b. Ruptured S/G narrow range level b. Control charging flow to LESS THAN 90% [85% adverse maintain RCS pressure at CNMT) ruptured S/G pressure and go to Step 37.
c. Ruptured S/G narrow range level c. IF ruptured S/G level STABLE OR DECREASING increasing, THEN decrease charging flow to stabilize level. Maintain RCS subcooling greater than 20'F using Figure MIN SUBCOOLING ~

Ig '.

\ I

EOP: T1TLE:

REV: 12 ECA-,3. 3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL I

PAGE 27 of 27 STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED

  • 37 Monitor RCP Operation:
a. RCPs - ANY RUNNING a. Go to Step 39.
b. Check the following: b. Stop the affected RCP(s).

o RCP ¹1 seal D/P - GREATER THAN 220 PSID o Check RCP seal leakage WITHIN THE NORMAL OPERATING RANGE OF FIGURE RCP SEAL LEAKOFF 38 Check Core Exit T/Cs LESS Return to Step 34.

THAN 200'F 39 Evaluate Long Term Plant Status:

a. Maintain cold shutdown conditions
b. Consult TSC

-END-

EOP: TITLE:

REV: 12 ECA-3. 3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 1 of 1 ECA-3.3 APPENDIX LIST TITLE PAGES

1) RED PATH

SUMMARY

2) FIGURE MIN SUBCOOLING
3) FIGURE SDM
4) FIGURE RCP SEAL LEAKOFF
5) ATTACHMENT RCP START
6) ATTACHMENT N2 PORVS
7) ATTACHMENT RUPTURED S/G
8) ATTACHMENT D/G STOP
9) ATTACHMENT SD-1
10) ATTACHMENT SEAL COOLING
11) ATTACHMENT SD-2
12) ATTACHMENT RHR COOL
13) ATTACHMENT AUX BLDG SW
14) FOLDOUT

J f

EOP: TITLE:

REV 12

,ECA-~.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 1 of 1 RED PATH

SUMMARY

a. SUBCRITICALITY Nuclear power greater than 5t
b. CORE COOLING Core exit T/Cs greater than 1200'F

-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs) less than 434 [464 adverse CNMT]

c. HEAT SINK Narrow range level in all S/Gs less than 54

[254 adverse CNMT] AND total feedwater flow less than 200 gpm

d. INTEGRITY Cold leg temperatures decrease greater than 100 F in last 60 minutes AND RCS cold leg temperature less than 285'F
e. CONTAINMENT CNMT pressure greater than 60 psig

0 ~

f r>,(

J lO pl/

h

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL

~z ~ ~

PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE: Subcooling Margin = Saturation Temperature From Figure Below [-] Core Exit T/C Indication RC S PRESSURE (PSIG) 2500 2400 RCS PRESSURE 2300 INCREMENTS 20 PSIG 2200 2100 2000 1900 1800 1700 1600 1500 SUBCOOLED 1300 REGION 1200 1100 1000 900 800 INADEQUATE 700 SUBCOOLING

'00 ADVERSE CNMT REGION 500 400 300 200 NORMAL CNMT TEMPERATURE INCREMENTS 10'F 100 0

200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE ('F)

~ ~ qs l.'

V 4

EOP: TITLE REV 12 EGA,-3 ~ 3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL PAGE 1 of 1 FIGURE SDM NOTE: o Curve includes allowance for one stuck rod. Add 100 ppm for each additional stuck rod.

o To obtain core burnup, use PPCS point ID BURNUP.

BORON CONCENTRATION (PPM) 1800 BORON INCREMENTS 20 PPH 1600 1400 ADEQUATE SDH 1200 100 PPH CONSERVATISH INCLUDED 1000 800 600 400 200 BURNUP INCREMENTS 100 MWD/MTU 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 CYCLE 25 BURNUP (MWD/MTU)

I' i 0

~

~ 't C

a~ 'l (A

f~<

4( j

EOP: TITLE:

REV: 12 ECA-3.3 SGTR WITHOUT PRESSURIZER PRESSURE CONTROL

~ r PAGE 1 of 1 FIGURE RCP SEAL LEAKOFF

¹1 SEAL LEAK RATE (GPH) 6 LEAK RATE INCREHENTS 0.2 GPH NORHAL OPERATING RANGE DP INCREHENTS 50 PSI 250 500 750 1000 1250 1500 1750 2000 2250 2500

¹1 SEAL DP (RCS PRESS - VCT PRESS) PSI

~e W~'