Line 3: Line 3:
| issue date = 10/09/1979
| issue date = 10/09/1979
| title = LER 79-030/03L-0:on 790909,while at 81% Power,Delta Flux Indication Was Below Tech Spec Limit.Caused by Operator Error.Procedures Have Been Revised
| title = LER 79-030/03L-0:on 790909,while at 81% Power,Delta Flux Indication Was Below Tech Spec Limit.Caused by Operator Error.Procedures Have Been Revised
| author name = MURPHY C E
| author name = Murphy C
| author affiliation = INDIANA MICHIGAN POWER CO.
| author affiliation = INDIANA MICHIGAN POWER CO.
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:U.S.NUCLEARREGULATORY COMMISSION NTREPORTtPLEASEPRINTORTYPEALLREQUIREDINFORMATION)
{{#Wiki_filter:NRC FORM 366                                                                                                                            U. S. NUCLEAR REGULATORY COMMISSION (7.77)
NRCFORM366(7.77)P~CONTROLBLOCK:ENSEEEVEQI3Q~O2526LICENSETYPE3057CAT58Q0980I,6[OO~]Q2OOOOOO789LICENSEECODE1415LICENSENUMBERCON'T01soURGEMLQBO5OOO316Q7O9O979QB100986061DOCKETNUMBER6869FVENTDATE7475REPORTDATEEVENTDESCRIPTION ANDPROBABL.E CONSEQUENCES Q10~02,AFTERCOMPLETION OFINCOREEXCORECROSSCALIRAT~03POWERWASBEINGESCALATED TO100%.ONREACHING"81%
P   ~                                                     ENSEE EVE NT REPORT CONTROL BLOCK:                                                       QI                tPLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)
POWERTHEDELTAFLUXINDICA-TIONWASOUTOFTHETARGETBANDFORAN'.ESTIMATED 21-22MINUTES.TH~OS~06TECHNICAL SPECIFICATION LIMITOF84%'BUTVIOLATESAMORERESTRICTIVE ADMINISTRATIV LIMITOF81%IMPOSEDPENDINGREVISIONOFTECHNICAL PF~07~OB8078~0978SYSTEMCAUSECAUSECOMP.VALVECODECODESUBCODECOMPONENT CODESUBCODESUBCODE~XXQ11DQ12~1Q13ZZZZZZQE~ZQEE~ZQER910111213181920SEQUENTIAL OCCURRENCE REPORTREVISIONLFRIROEVENTYEARREPORTNO.CODETYPENO.Q17REPORT~79~~QQ2122232426272829303132ACTIONFUTUREEFFECTSHUTDOWNATTACHMENT NPRDQPRIMECOMP.COMPONENT TAKENACTIONONPLANTMETHODHOURSQ22SUBMITTED FORMSUB.SUPPLIERMANUFACTURER
[OO~]
~GQ)B~ZQ19,~ZQ20MZQ21<<<<~YQ23I~IQ24L~JQ26>>>>Q"3334353637404142434447CAUSEDESCRIPTION ANDCORRECTIVE ACTIONSQ27oTHEOPERATORWHILEPERFORMING THEPAXIALFLUXLIMITSDIFFERENCE ASSHOWNTIVELIMITSIMPOSEDPENDINGREVISIONOFTECHNICAL SPECIFIATINT3THEDELTAFLUXGOINGSLIGHTLYOUTOFTHETARGETBANDBETWEEN81-2.P80DISCOVERY DESCRIPTION Q32NUCLEARSECTION80LOCATIONOFRELEASEQ8044808080NRCUSEONLY280'465-5901X-3166869PHONE.616C.E.MURPHYNAMEOFPREPARER4CONTROLROOMCOPYOFTHETECH.SPEC.GRAPHHASBEENUPDAT789FACILITY~30METHODOFSTATUS~DIPPOWEROTHERSTATUS~DISCOVERY LUO23~08IQNA~AQ31789101213444546ACTIVITYCONTENTRELEASEDOFRELEASEAMOUNTOFACTIVITYEZL~JOL~JQNA789101145PERSONNEL EXPOSURES NUMBERTYPEDESCRIPTION Q3~IN7891112LOSSOFORDAMAGETOFACILITYQ43TYPEDESCRIPTION ZQ4.NA78910PUBLICITY ISSUEDDESCRIPTION KDOMNQ4"NA78910
7        8    9        LICENSEE CODE I
~)w~h  
14 Q2OOOOOO 15
~~ATTACHMENT TOLER879-030/03L-0 PAGE2CAUSEDESCRIPTION ANDCORRECTIVE ACTIONS:ADMINISTRATIVE LIMITSANDTHEINCORE/EXCORE TESTPROCEDURE HASBEENCHANGEDTOREQUIREOPERATORSIGNOFFTHATTHEAXIALFLUXDIFFERENCE ISWITHINTHETARGETBANDPRIORTOPOWERESCALATION.  
                                                                                  ,6 LICENSE NUMBER                        25 Q3    26      LICENSE TYPE        30 Q~O 57 CAT 58 CON'T 0  1                          MLQB              O    5      O    O    O    3    1    6    Q7    O    9    O    9    7      9    QB    1      0    0    9            09 soURGE                                                                                                                74      75        REPORT DATE        80 8                        60              61              DOCKET NUMBER              68      69        F VENT DATE EVENT DESCRIPTION AND PROBABL.E CONSEQUENCES                                   Q10
~~'ve'e<~+lt}}
~02,               AFTER COMPLETION OF INCORE EXCORE CROSS CALI RAT
~03                POWER WAS                BEING ESCALATED TO 100%.                           ON    REACHING"81% POWER THE DELTA FLUX INDICA-TION        WAS OUT OF THE TARGET BAND FOR                                  AN'.ESTIMATED           21-22 MINUTES.                   TH
~OS                 TECHNICAL SPECIFICATION                               LIMIT OF 84%'BUT VIOLATES                        A MORE RESTRICTIVE ADMINISTRATIV
~06                LIMIT OF              81% IMPOSED PENDING REVISION OF TECHNICAL                                            P        F
~07
~OB                                                                                                                                                                                      80 7        8 SYSTEM              CAUSE          CAUSE                                                          COMP.          VALVE CODE                CODE        SUBCODE                  COMPONENT CODE                      SUBCODE          SUBCODE
~09                                  ~XX            Q11          D Q12      ~1Q13 13 Z    Z    Z    Z    Z    Z 18 QE        ~ZQEE 19
                                                                                                                                                              ~Z 20 QER 7        8                          9            10            11            12 SEQUENTIAL                          OCCURRENCE             REPORT                      REVISION Q17 LF RIRO REPORT EVENT YEAR
                                        ~79                     ~                 REPORT NO.
                                                                                ~QQ CODE                TYPE                          NO.
21          22          23            24            26        27            28        29          30              31          32 ATTACHMENT            NPRDQ          PRIME COMP.            COMPONENT Q26>>>>
ACTION FUTURE                        EFFECT          SHUTDOWN TAKEN ACTION                        ON PLANT            METHOD                  HOURS Q22          SUBMITTED          FORM SUB.         SUPPLIER            MANUFACTURER
                ~GQ)B 33
                            ~Z Q19, ~Z 34                    35 Q20        MZ 36 Q21 37                    40
                                                                                                                    ~Y 41 Q23        I~I 42 Q24        L~ J 43              44            47 Q"
CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o            THE OPERATOR                      WHILE PERFORMING THE                    P AXIAL FLUX LIMITS DIFFERENCE AS                                      SHOWN TIVE LIMITS IMPOSED PENDING REVISION OF TECHNICAL SPECIFI ATI                                                                    N      T 3            THE DELTA FLUX GOING SLIGHTLY OUT OF THE TARGET BAND BETWEEN                                                                  81- 2.         P 4            CONTROL ROOM COPY OF THE TECH. SPEC.                                           GRAPH HAS BEEN UPDAT 80 7        8    9 FACILITY STATUS    ~
                                ~08 DIP POWER                        OTHER STATUS      ~
                                                                                        ~30      METHOD OF DISCOVERY                                DISCOVERY DESCRIPTION Q32 7      8 LUO23 9                10 I
12 Q    13 NA 44
                                                                                                    ~AQ31 45          46 NUCLEAR SECTION 80 ACTIVITY        CONTENT RELEASED OF RELEASE                              AMOUNT OF ACTIVITY                                                          LOCATION OF RELEASE          Q EZ 7      8 L~JO 9
L~JQ 10              11 NA 44            45                                                                            80 PERSONNEL EXPOSURES NUMBER                  TYPE          DESCRIPTION    Q3 80 8    9                  11        12
                                                                                                                        ~IN                                                            80 7
LOSS OF OR DAMAGE TO FACILITY TYPE        DESCRIPTION                        Q43 Z  Q4.                             NA 8    9          10                                                                                                                                                            80 7
PUBLICITY                                                                                                                                        NRC USE ONLY ISSUED      DESCRIPTION KDO MNQ4"                                           NA 68    69                        80' 2
7        8    9          10 C. E. MURPHY                                              PHONE.            61 6      465-5901      X-316 NAME OF PREPARER
 
      ~ )
w ~
h
 
    ~ ~
ATTACHMENT TO LER 8 79-030/03L-0 PAGE 2 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS:
ADMINISTRATIVE LIMITS AND THE INCORE/EXCORE TEST PROCEDURE HAS BEEN CHANGED TO REQUIRE OPERATOR SIGNOFF THAT THE AXIAL FLUX DIFFERENCE IS WITHIN THE TARGET BAND PRIOR TO POWER ESCALATION.
 
    ~ ~
v e'e <
              ~
                +
t l}}

Latest revision as of 01:10, 4 February 2020

LER 79-030/03L-0:on 790909,while at 81% Power,Delta Flux Indication Was Below Tech Spec Limit.Caused by Operator Error.Procedures Have Been Revised
ML17326A283
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 10/09/1979
From: Murphy C
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17318A334 List:
References
LER-79-030-03L-01, LER-79-30-3L-1, NUDOCS 7910160507
Download: ML17326A283 (4)


Text

NRC FORM 366 U. S. NUCLEAR REGULATORY COMMISSION (7.77)

P ~ ENSEE EVE NT REPORT CONTROL BLOCK: QI tPLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

[OO~]

7 8 9 LICENSEE CODE I

14 Q2OOOOOO 15

,6 LICENSE NUMBER 25 Q3 26 LICENSE TYPE 30 Q~O 57 CAT 58 CON'T 0 1 MLQB O 5 O O O 3 1 6 Q7 O 9 O 9 7 9 QB 1 0 0 9 09 soURGE 74 75 REPORT DATE 80 8 60 61 DOCKET NUMBER 68 69 F VENT DATE EVENT DESCRIPTION AND PROBABL.E CONSEQUENCES Q10

~02, AFTER COMPLETION OF INCORE EXCORE CROSS CALI RAT

~03 POWER WAS BEING ESCALATED TO 100%. ON REACHING"81% POWER THE DELTA FLUX INDICA-TION WAS OUT OF THE TARGET BAND FOR AN'.ESTIMATED 21-22 MINUTES. TH

~OS TECHNICAL SPECIFICATION LIMIT OF 84%'BUT VIOLATES A MORE RESTRICTIVE ADMINISTRATIV

~06 LIMIT OF 81% IMPOSED PENDING REVISION OF TECHNICAL P F

~07

~OB 80 7 8 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~09 ~XX Q11 D Q12 ~1Q13 13 Z Z Z Z Z Z 18 QE ~ZQEE 19

~Z 20 QER 7 8 9 10 11 12 SEQUENTIAL OCCURRENCE REPORT REVISION Q17 LF RIRO REPORT EVENT YEAR

~79 ~ REPORT NO.

~QQ CODE TYPE NO.

21 22 23 24 26 27 28 29 30 31 32 ATTACHMENT NPRDQ PRIME COMP. COMPONENT Q26>>>>

ACTION FUTURE EFFECT SHUTDOWN TAKEN ACTION ON PLANT METHOD HOURS Q22 SUBMITTED FORM SUB. SUPPLIER MANUFACTURER

~GQ)B 33

~Z Q19, ~Z 34 35 Q20 MZ 36 Q21 37 40

~Y 41 Q23 I~I 42 Q24 L~ J 43 44 47 Q"

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o THE OPERATOR WHILE PERFORMING THE P AXIAL FLUX LIMITS DIFFERENCE AS SHOWN TIVE LIMITS IMPOSED PENDING REVISION OF TECHNICAL SPECIFI ATI N T 3 THE DELTA FLUX GOING SLIGHTLY OUT OF THE TARGET BAND BETWEEN 81- 2. P 4 CONTROL ROOM COPY OF THE TECH. SPEC. GRAPH HAS BEEN UPDAT 80 7 8 9 FACILITY STATUS ~

~08 DIP POWER OTHER STATUS ~

~30 METHOD OF DISCOVERY DISCOVERY DESCRIPTION Q32 7 8 LUO23 9 10 I

12 Q 13 NA 44

~AQ31 45 46 NUCLEAR SECTION 80 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE Q EZ 7 8 L~JO 9

L~JQ 10 11 NA 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION Q3 80 8 9 11 12

~IN 80 7

LOSS OF OR DAMAGE TO FACILITY TYPE DESCRIPTION Q43 Z Q4. NA 8 9 10 80 7

PUBLICITY NRC USE ONLY ISSUED DESCRIPTION KDO MNQ4" NA 68 69 80' 2

7 8 9 10 C. E. MURPHY PHONE. 61 6 465-5901 X-316 NAME OF PREPARER

~ )

w ~

h

~ ~

ATTACHMENT TO LER 8 79-030/03L-0 PAGE 2 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS:

ADMINISTRATIVE LIMITS AND THE INCORE/EXCORE TEST PROCEDURE HAS BEEN CHANGED TO REQUIRE OPERATOR SIGNOFF THAT THE AXIAL FLUX DIFFERENCE IS WITHIN THE TARGET BAND PRIOR TO POWER ESCALATION.

~ ~

v e'e <

~

+

t l