| issue date = 02/27/1980
| issue date = 02/27/1980
| title = LER 80-004/03L-0:on 800202,during Normal Operation,While Investigating Problem W/Test Circuit for B Main Turbine Stop Valve,Found Mounting Bracket for Proximity Switch Failed. Caused by Loosened Mounting Assembly Due to Vibration
| title = LER 80-004/03L-0:on 800202,during Normal Operation,While Investigating Problem W/Test Circuit for B Main Turbine Stop Valve,Found Mounting Bracket for Proximity Switch Failed. Caused by Loosened Mounting Assembly Due to Vibration
| author name = RISCHLING J
| author name = Rischling J
| author affiliation = INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
| author affiliation = INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:)V,.+CFOSIMi366
{{#Wiki_filter:)V,.+C  FOSIMi366                                                                                                                                I~NUCLEAR REGULATORY COMI))IISSION
{777ILICENSEEEVENTREPORTI~NUCLEAR REGULATORY COMI))IISSION78CON'TCONTROLBLOCK:IfIMtiDfcC~JQ29LICENSEECODEI2)~u~lLJ~
{7 77I LICENSEE EVENT REPORT CONTROL BLOCK:                          I      f                I        Qi                'PLEASE PRINT OR TYPE ALL REQUIREO INFORhlATIONI I
QsLICENSENUIEIBERIQi'PLEASEPRINTORTYPEALLREQUIREOINFORhlATIONI OloOO"oo'"oo~LQR~0500I03III0'Q)jo2026061DOCKETNUMBER6869EVENTDATEEVENTDESCRIPTION ANDPROBABLECONSEQUE)4CES QIOL-''2~01Qs0221780/09787476RCPORTDATE80THE"B"'AINTURBINESTOPVALVE,ITWASDISCOVERED THATTHEMOUN'IINGBRACKETFORTHEIPROXIMITY SWITCHHADf:AILED.THISPROXIMITY SWITCHPROVIDESTURBINESTOPVAlVEIOIS.CLOSUREINDICATIOII FORTHEREACTORPROTECTION SYSTEM.THISISNON-CONSERVATIVE IN.RESPECTTO.-T.S.TABLE3.3-1iTEM18.B.THEAFFECTEDCHANNFLWASPLACEDINTHETRIPLCONOIYIOAII ASREOUIREO.
7          8      9 Mti              D  fc LICENSEE CODE C      ~JQ2              Olo          O          O LICENSE NUIEIBER I  2)~u~lLJ~                                               Qs CON'T
~OS80789SYSTEMCAUSECAUSECOMP.VALVECODECODE"SUBCODECOMPONENT CODESUBCODESUBCODE~o)2~t>Q>>2Q~Q~I~Y~LIIIQ LLIQ[z>Q789101112131819SEQUENTIAL OCCURRENCE RLPOPTREVISIOI'I LERIRQFVENTYEARRFPORTNO.CODE)YPENQ.G)llo)ORT~gP~~PPO.~~[gJ~2122232426272829,30~3132ACTIOi4FUTUREEFFECTSHVTDOENE4 ATTACHMENT NPRO4PRIMECOMP.COMPOi'IENT TAKENACTIONONPLANTh'IETHODHOURSQ22SUBMITTED FORh1SUB.SUPPLIFRMANUFACTURER
~01                        "oo'"oo       ~LQR~05                        0    0  I 0      3  I I  I 0  'Q)jo          2    0    2              Qs      0      2      21    7    8      0/09 7          8                              60            61              DOCKET NUMBER                  68      69        EVENT DATE            74      76        RCPORT DATE                80 EVENT DESCRIPTION AND PROBABLE CONSEQUE)4CES QIO 2        L            ''
~OQTR~ZQER~ZQ)o~ZQst~0~00I0.IYIQ22~NQ24LAgQ>>~i~l~liQRF 3334"353637404142434447CAUSEOFSCRIPTICN ANOCORRECTIVE ACTIONSQ27V*TIIITIOAlt-"ALEIIIRI'''IIELISt2AEV:.AO~
THE          "B"'AIN TURBINE                        STOP VALVE,             IT  WAS      DISCOVERED THAT THE MOUN'I ING BRACKET FOR THE                                            I PROXIMITY SWITCH HAD f:AILED.                                         THIS PROXIMITY SWITCH PROVIDES TURBINE STOP VAlVE                                                            I O  IS              .CLOSURE INDICATIOII FOR THE REACTOR PROTECTION SYSTEM.                                                               THIS IS NON-CONSERVATIVE IN RESPECT TO.-T.S.                       TABLE        3.3-1        iTEM 18.B.             THE AFFECTED CHANNFL WAS PLACED IN THE TRIP CONOIYIOAII AS REOUIREO.
tTAIIi.IVIIEVE,IItTItlIilIOIIL0"AVE:tVE~IIVEVENTSTOPVALVE"B"HADACTUALLYSHUT.THEPROXIMITY SWITCHITSELFDIDNOTFAIL.3.THE'FAILURF.
L
WAIN"tINTIGASSEMBLY.
~OS 7          8 9                                                                                                                                                                                            80 SYSTEM                CAUSE          CAUSE                                                          COMP.               VALVE
WHICHVIBRATEDIOSE.TPRFFSEEATTACHEDSUPPLEMENT.
~o)     2                                     ~t>
INTt'J789FACILITYSTATUS41PONIERoTHERSTATUS0~'E100"9NAMETHODOF)DISCOVERY DISCOVERY DESCRIPTION 022~AQSI[OPERATOROBSERVATION LOCATIONOFRELEASEQSBNRCUSEONLY'IIIIII6869616-465-5901 8003.{9@{6 10JackRisch'ting PHONc)4AMEOFPREPARERCKLJQ>>j~lQ78910121344ACTIVITYCOI4TENTRELEASEDOFRELEASEAMOUNTOFACIVITYQSS~1e~Z033~ZQ3.NA7891044PERSONNEL EXPOSURES NUMBERTYPEDESCRIPTION 039)~000Qs)~ZQ)sNA789114213PERSCi4NEL INJURIESNUMBERDESCRIPTION 41~OIOOQ4oj)PA7891112LOSSOFORDAMAGEToFACILITYQ43789~'1045PUBLICI~'4ISSUEDDESCRIPTION Qgjoo.I)IJ(43808080)2oi300 SUPPLEMENT TOLFRiv'80-004/03L-0 SUPPLEMENT TOCAUSEDESCRIPTION
CODE                  CODE" 2    Q         ~Q SUBCODE                    COMPONENT CODE
.ASSEMBLYANDPROXIMITY SWITCHCONFIGURATION MASINSTALLED ASARESULTOF:-.-:--.APREVIOUSENGINEERING EVALUATION.
                                                                                                          ~I~Y~LIIIQ LLIQ SUBCODE          SUBCODE
NOFURTHERACTiONISPRESENTLY PLANNEDASARESULTOFTHISEVENT.}}
[z> Q
                                                                                                                              ''I Q>>
7          8                                9          10            11              12            13                                18          19 SEQUENTIAL                            OCCURRENCE           RLPOPT                            REVISIOI'I G)
ACTIOi4 FUTURE LERIRQ llo)ORT FVENT YEAR
                                                ~gP 21          22 EFFECT
                                                                        ~
23 SHVTDOENE4
                                                                                          ~PP 24 RFPORT NO.
O .
26
                                                                                                                      ~~
27            28 ATTACHMENT CODE
[gJ~29, NPRO 4
                                                                                                                                                          )YPE 30           ~
PRIME COMP.
31            32 NQ.
COMPOi'IENT TAKEN ACTION                          ON PLANT              h'IETHOD                    HOURS Q22          SUBMITTED        FORh1 SUB.       SUPPLIFR                MANUFACTURER
                  ~OQTR ~ZQER 33                34            "    ~ZQ)o 35
                                                                              ~ZQst 36                37
                                                                                                  ~0~00            I  0.
40 IY 41 I Q22      ~NQ24              LAgQ>>               ~i~l~liQRF 42                43                  44                  47 CAUSE OFSCRIPTICN ANO CORRECTIVE ACTIONS Q27 V* TI IITIOA                  lt-"     ALE        II            I    R        I'                                               IELI St 2AEV:.AO~
t TAI            Ii    . IVIIEVE,               II      tT    Itl I    il IOIIL            0    "AVE:           tVE                           ~
IIV EVENT STOP VALVE                          "B"     HAD ACTUALLY SHUT.                     THE PROXIMITY SWITCH ITSELF DID NOT                                      FAIL.
3             .THE'FAILURF.                 WA        IN        " tI    NTI      G  ASSEMBLY. WHICH VIBRATED I OSE.                               T          PRF F                IN  Tt'J SEE ATTACHED SUPPLEMENT.
0 7          8    9
                                                                                                                                                                                    )
CK LJQ>>
7
  ~
8 FACILITY STATUS 9
                      'E ACTIVITY COI4TENT j~lQ 10 1
41  PONIER 0      0 12 "9
13 oTHER STATUS NA 44 METHOD OF DISCOVERY
                                                                                                              ~A QSI[
DISCOVERY DESCRIPTION 022 OPERATOR OBSERVATION RELEASED OF RELEASE                                    AMOUNT OF AC IVITY QSS                                                        LOCATION OF RELEASE QSB
~1e             ~Z            033      ~ZQ3.                       NA 7        8    9                      10                                                            44 PERSONNEL EXPOSURES NUMBER                    TYPE          DESCRIPTION 039
        )     ~00                    0  Qs)   ~ZQ)s            NA 7          8    9                        11        42            13                                                                                                                                      80 PERSCi4NEL INJURIES NUMBER                    DESCRIPTION 41
                ~OI            O        O Q4oj                      )PA 7          8    9                        11        12                                                                                                                                                    80 LOSS OF OR DAMAGE To FACILITY Q43 7          8    9          ~       '10 80 PUBLICI ~ '4 ISSUED              DESCRIPTION 45    Q                                                    8003.{9@{6                                                  '
NRC USE ONLY
                                                                                                                                                                                                                )2 oi g    j oo. I     )IJ(43 10                                                                                                                          68    69 I  I    I  I  I        I 30
                                    )4AME OF PREPARER                          Jack Risch'ting                                                PHONc 616-465-5901                                  0
 
SUPPLEMENT TO LFR iv'80-004/03L-0 SUPPLEMENT TO CAUSE DESCRIPTION
        . ASSEMBLY AND PROXIMITY SWITCH CONFIGURATION MAS INSTALLED AS A RESULT OF
: .-:-- .A PREVIOUS ENGINEERING EVALUATION. NO FURTHER ACTiON IS PRESENTLY PLANNED AS A RESULT OF THIS EVENT.}}

Latest revision as of 01:07, 4 February 2020

LER 80-004/03L-0:on 800202,during Normal Operation,While Investigating Problem W/Test Circuit for B Main Turbine Stop Valve,Found Mounting Bracket for Proximity Switch Failed. Caused by Loosened Mounting Assembly Due to Vibration
ML17326A546
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 02/27/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17326A545 List:
References
LER-80-004-03L, LER-80-4-3L, NUDOCS 8003040582
Download: ML17326A546 (2)


Text

)V,.+C FOSIMi366 I~NUCLEAR REGULATORY COMI))IISSION

{7 77I LICENSEE EVENT REPORT CONTROL BLOCK: I f I Qi 'PLEASE PRINT OR TYPE ALL REQUIREO INFORhlATIONI I

7 8 9 Mti D fc LICENSEE CODE C ~JQ2 Olo O O LICENSE NUIEIBER I 2)~u~lLJ~ Qs CON'T

~01 "oo'"oo ~LQR~05 0 0 I 0 3 I I I 0 'Q)jo 2 0 2 Qs 0 2 21 7 8 0/09 7 8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 76 RCPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUE)4CES QIO 2 L

THE "B"'AIN TURBINE STOP VALVE, IT WAS DISCOVERED THAT THE MOUN'I ING BRACKET FOR THE I PROXIMITY SWITCH HAD f:AILED. THIS PROXIMITY SWITCH PROVIDES TURBINE STOP VAlVE I O IS .CLOSURE INDICATIOII FOR THE REACTOR PROTECTION SYSTEM. THIS IS NON-CONSERVATIVE IN RESPECT TO.-T.S. TABLE 3.3-1 iTEM 18.B. THE AFFECTED CHANNFL WAS PLACED IN THE TRIP CONOIYIOAII AS REOUIREO.

L

~OS 7 8 9 80 SYSTEM CAUSE CAUSE COMP. VALVE

~o) 2 ~t>

CODE CODE" 2 Q ~Q SUBCODE COMPONENT CODE

~I~Y~LIIIQ LLIQ SUBCODE SUBCODE

[z> Q

I Q>>

7 8 9 10 11 12 13 18 19 SEQUENTIAL OCCURRENCE RLPOPT REVISIOI'I G)

ACTIOi4 FUTURE LERIRQ llo)ORT FVENT YEAR

~gP 21 22 EFFECT

~

23 SHVTDOENE4

~PP 24 RFPORT NO.

O .

26

~~

27 28 ATTACHMENT CODE

[gJ~29, NPRO 4

)YPE 30 ~

PRIME COMP.

31 32 NQ.

COMPOi'IENT TAKEN ACTION ON PLANT h'IETHOD HOURS Q22 SUBMITTED FORh1 SUB. SUPPLIFR MANUFACTURER

~OQTR ~ZQER 33 34 " ~ZQ)o 35

~ZQst 36 37

~0~00 I 0.

40 IY 41 I Q22 ~NQ24 LAgQ>> ~i~l~liQRF 42 43 44 47 CAUSE OFSCRIPTICN ANO CORRECTIVE ACTIONS Q27 V* TI IITIOA lt-" ALE II I R I' IELI St 2AEV:.AO~

t TAI Ii . IVIIEVE, II tT Itl I il IOIIL 0 "AVE: tVE ~

IIV EVENT STOP VALVE "B" HAD ACTUALLY SHUT. THE PROXIMITY SWITCH ITSELF DID NOT FAIL.

3 .THE'FAILURF. WA IN " tI NTI G ASSEMBLY. WHICH VIBRATED I OSE. T PRF F IN Tt'J SEE ATTACHED SUPPLEMENT.

0 7 8 9

)

CK LJQ>>

7

~

8 FACILITY STATUS 9

'E ACTIVITY COI4TENT j~lQ 10 1

41 PONIER 0 0 12 "9

13 oTHER STATUS NA 44 METHOD OF DISCOVERY

~A QSI[

DISCOVERY DESCRIPTION 022 OPERATOR OBSERVATION RELEASED OF RELEASE AMOUNT OF AC IVITY QSS LOCATION OF RELEASE QSB

~1e ~Z 033 ~ZQ3. NA 7 8 9 10 44 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION 039

) ~00 0 Qs) ~ZQ)s NA 7 8 9 11 42 13 80 PERSCi4NEL INJURIES NUMBER DESCRIPTION 41

~OI O O Q4oj )PA 7 8 9 11 12 80 LOSS OF OR DAMAGE To FACILITY Q43 7 8 9 ~ '10 80 PUBLICI ~ '4 ISSUED DESCRIPTION 45 Q 8003.{9@{6 '

NRC USE ONLY

)2 oi g j oo. I )IJ(43 10 68 69 I I I I I I 30

)4AME OF PREPARER Jack Risch'ting PHONc 616-465-5901 0

SUPPLEMENT TO LFR iv'80-004/03L-0 SUPPLEMENT TO CAUSE DESCRIPTION

. ASSEMBLY AND PROXIMITY SWITCH CONFIGURATION MAS INSTALLED AS A RESULT OF

.-:-- .A PREVIOUS ENGINEERING EVALUATION. NO FURTHER ACTiON IS PRESENTLY PLANNED AS A RESULT OF THIS EVENT.