ML17326A545

From kanterella
Jump to navigation Jump to search
Forwards LER 80-004/03L-0
Date released: 05/31/2018 Download: ML17326A545


LER 80-004/03L-0:on 800202,during Normal Operation,While Investigating Problem W/Test Circuit for B Main Turbine Stop Valve,Found Mounting Bracket for Proximity Switch Failed. Caused by Loosened Mounting Assembly Due to Vibration
ML17326A546
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 02/27/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A546 (2)
Forwards LER 80-004/03L-0
ML17326A544
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 02/27/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A544 (1)