{{#Wiki_filter:WEPLF CREEK'NUCLEAR OPERATING CORPORATION Annette F. Stull Vice President and Chief Administrative Officer March 24, 2009 (620)364-4004 (620)364-4017 facsimile anstull@wcnoc.com CT 09-0014 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555  
{{#Wiki_filter:WEPLF CREEK       'NUCLEAR OPERATING CORPORATION Annette F. Stull Vice President and Chief Administrative Officer                                   March 24, 2009 (620)364-4004 (620)364-4017 facsimile anstull@wcnoc.com CT 09-0014 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555


==Subject:==
==Subject:==
Docket No. 50-482: Financial Protection Levels Gentlemen:
Docket No. 50-482: Financial Protection Levels Gentlemen:
Wolf Creek Nuclear Operating Corporation is reporting the present damage insurance being maintained for Wolf Creek Generating requirements of 10 CFR 50.54(w)(3):
Wolf Creek Nuclear Operating Corporation is reporting the present levels of on-site property damage insurance being maintained for Wolf Creek Generating Station pursuant to the requirements of 10 CFR 50.54(w)(3):
levels of on-site property Station pursuant to the Insurer Nuclear Electric Insurance Limited Nuclear Electric Insurance Limited Total Nuclear Property Insurance Policy Number P09-062 X09-059 Limits$ 500 Million$2,250 Million$2,750 Million There are no commitments contained in this correspondence.
Insurer                                                                 Policy Number            Limits Nuclear Electric Insurance Limited                                     P09-062                  $ 500 Million Nuclear Electric Insurance Limited                                     X09-059                 $2,250 Million Total Nuclear Property Insurance                                                                $2,750 Million There are no commitments contained in this correspondence. If you. have any questions concerning this matter, please contact me at (620) 364-4004, or Mr. Richard Flannigan at (620) 364-4117.
If you. have any questions concerning this matter, please contact me at (620) 364-4004, or Mr. Richard Flannigan at (620)364-4117.Sincerely, Annette F. Stull AFS/rlt cc: E. E. Collins (NRC)A. K. Cool (WR)V. G. Gaddy (NRC)J. J. Guerrero (Marsh)T. N. Laflin (WCNOC)B. K. Singal (NRC)Senior Resident Inspector (NRC)P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET}}
Sincerely, Annette F. Stull AFS/rlt cc: E. E. Collins (NRC)
A. K. Cool (WR)
V. G. Gaddy (NRC)
J. J. Guerrero (Marsh)
T. N. Laflin (WCNOC)
B. K. Singal (NRC)
Senior Resident Inspector (NRC)
P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET}}

Latest revision as of 07:28, 14 November 2019

On-Site Property Damage Insurance
ML090910708
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 03/24/2009
From: Stull A
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CT 09-0014
Download: ML090910708 (1)


Text

WEPLF CREEK 'NUCLEAR OPERATING CORPORATION Annette F. Stull Vice President and Chief Administrative Officer March 24, 2009 (620)364-4004 (620)364-4017 facsimile anstull@wcnoc.com CT 09-0014 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482: Financial Protection Levels Gentlemen:

Wolf Creek Nuclear Operating Corporation is reporting the present levels of on-site property damage insurance being maintained for Wolf Creek Generating Station pursuant to the requirements of 10 CFR 50.54(w)(3):

Insurer Policy Number Limits Nuclear Electric Insurance Limited P09-062 $ 500 Million Nuclear Electric Insurance Limited X09-059 $2,250 Million Total Nuclear Property Insurance $2,750 Million There are no commitments contained in this correspondence. If you. have any questions concerning this matter, please contact me at (620) 364-4004, or Mr. Richard Flannigan at (620) 364-4117.

Sincerely, Annette F. Stull AFS/rlt cc: E. E. Collins (NRC)

A. K. Cool (WR)

V. G. Gaddy (NRC)

J. J. Guerrero (Marsh)

T. N. Laflin (WCNOC)

B. K. Singal (NRC)

Senior Resident Inspector (NRC)

P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET