{{#Wiki_filter:ENT000062 Submitted: March 28, 2012 FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                        SC  AF                        G            SI                            KS R              IN        R OR EQ K                O                              TI O                                      AT            IN SU FO LD                IN              ZE                    R M                      T                            R                                  N                                        IO              LA                AW                                          EM N                                  UES            K                                                                                N PA IN  TI ON                          PI U              EX                    T      W                              DES T              DR                  PE                          AR AM                          O                                                                          LO                  PIPE  PR R                                C                                          C                          EP CONDENSATE Inspect nozzle 1              CD-02.1A-01N      183277        00217613                                                  39ft elev at FWH #32A                  Y  Y  N  Y  EC-H-50061        14          CHECWORKS - Ranked high on the Service Life Report Inspect component D/S of Valve CD-02.1A-                                                                                            Inspect CHECWORKS Components CD-05V. Inspect back to back elbows , plus u/p                                                                                          02.1A-5V (Ranked high on the Service 42FT ELEV D/S OF 32 OF 32A FWH.
2              CD-02.1A-06E      183280        00217616    and d/s extensions. Elbows plus 3 inches on                                          Y  Y  N  Y  EC-H-50061        14"          Life Report). Components D/S of valve and valve CD-18 either sides of elbow welds. Inspect 6E/7E                                                                                          selected since valves are rarely UT TOGETHER                                                                                                                            INSPECTED DUE TO CONTOUR.
Inspect CHECWORKS Components CD-Inspect component D/S of Valve CD-02.1A-02.1A-5V (Ranked high on the Service 05V. Inspect back to back elbows , plus u/p 42FT ELEV D/S OF 32 OF 32A FWH.                                                        Life Report). Components D/S of valve 3              CD-02.1A-07E      183280        00217616    and d/s extensions. Elbows plus 3 inches on                                          Y  Y  N  Y  EC-H-50061        14" and valve CD-18                                                                        selected since valves are rarely UT either sides of elbow welds. Inspect 6E/7E INSPECTED DUE TO CONTOUR and in TOGETHER vecinity.
Inspect components 01n/03e together. Inspect 4              CD-02.1B-01N      183282        00217617    nozzle and elbow plus 3 inches d/s of the    39ft elev at FWH #32B                    Y  Y  N  Y  EC-H-50061        14"          CHECWORKS - Ranked high on the elbow weld.                                                                                                                          Service Life Report Inspect components 01n/03e together. Inspect 5              CD-02.1B-03E      183282        00217617    nozzle and elbow plus 3 inches d/s of the    39ft elev at FWH #32B                    Y  Y  N  Y  EC-H-50061        14" elbow weld.                                                                                                                          FEW INSPECTION IN SEGMENT Components CD-02.1B-7V (Ranked high component d/s of valve CD-02.1B-07V.                                                                                                on the Service Life Report). Components Inspect pipe & elbow. Inspect two pipe      42FT ELEV D/S OF 32B FWH. and                                                            D/S of valve selected since valves are 6              CD-02.1B-08P      183283        00217618                                                                                          Y  Y  N  Y  EC-H-50061        14" diameters =28 inches plus elbows & 3 inches valve CD-8                                                                              rarely UT INSPECTED DUE TO D/S of elbow weld. Inspect 8P/9E TOGETHER                                                                                            CONTOUR and it is in close proximity to the valve.
Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 7              CD-02.1C-01N      183285        217592                                                                                            Y  Y  N  Y  EC-H-50061        14" nozzle plus 2 pipe dia =28 inches of pipe      valve CD-8 CHECWORKS - Ranked high on the elbow plus 3 inches d/s of the elbow weld.
Service Life Report Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 8              CD-02.1C-02P      183285        217592                                                                                            Y  Y  N  Y  EC-H-50061        14" nozzle plus 2 pipe dia =28 inches of pipe      valve CD-8 elbow plus 3 inches d/s of the elbow weld.
FEW INSPECTION IN SEGMENT Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 9              CD-02.1C-03E      183285        217592                                                                                            Y  Y  N  Y  EC-H-50061        14" nozzle plus 2 pipe dia =28 inches of pipe      valve CD-8 elbow plus 3 inches d/s of the elbow weld.                                                                                          FEW INSPECTION IN SEGMENT 10              CD-05.1A-1N      183295        00217593    Inspect nozzle                                42 ft. Elev. At 35A FWH                Y  Y  N  Y  EC-H-50064        14"          CHECWORKS - Ranked high on the Service Life Report 1 of 18                                                                                      3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                    SC  AF                        G            SI                            KS R                IN        R OR EQ K                O                              TI O                                AT            IN SU FO LD                IN              ZE                    R M                        T                            R                                  N                                  IO                LA                AW                                            EM N                                    UES          K                                                                            N PA IN  TI ON                            PI U              EX                    T      W                              DES T              DR                  PE                          AR AM                          O                                                                        LO                PIPE  PR R                              C                                        C                        EP Inspect CHECWORKS Components CD-Inspect components d/s of valve CD-05.1A-                                                                                          05.1A-5V (Ranked high on the Service CD-05.1A-06P                                05V. Inspect pipe & elbow. Inspect two pipe 32 FT. ELEV. OFF 35A FWH; D/S OF                                                      Life Report). Components D/S of valve 11                                183297        00217594                                                                                      Y  Y  N  Y  EC-H-50064        14" (CD-05.1A-05V)                              diameters =28 inches plus elbows & 3 inches VALVE CD-18-1                                                                          selected since valves are rarely UT D/S of elbow weld. Inspect 6P/7E TOGETHER                                                                                          INSPECTED DUE TO CONTOUR and is in vecinity.
Inspect components d/s of valve CD-05.1A-05V. Inspect pipe & elbow. Inspect two pipe 32 FT. ELEV. OFF 35A FWH; D/S OF 12              CD-05.1A-07E      183297        00217594                                                                                      Y  Y  N  Y  EC-H-50064        14" diameters =28 inches plus elbows & 3 inches VALVE CD-18-1 D/S of elbow weld. Inspect 6P/7E TOGETHER FEW INSPECTION IN SEGMENT Inspect CHECWORKS Components CD-Inspect components d/s of valve CD-05.1B-05.1B-5V (Ranked high on the Service 05V. Inspect pipe, elbow & pipe. Inspect two 32 FT ELEV. OFF 35B FWH D/S OF                                                      Life Report). Components D/S of valve 13              CD-05.1B-06P      183304        00217596    pipe diameters =28 inches plus elbows & 3                                          Y  Y  N  Y  EC-H-50064        14" VALVE CD-18-2                                                                      selected since valves are rarely UT inches D/S of elbow welds. Inspect 6P/7E/8P INSPECTED DUE TO CONTOUR and is TOGETHER in vecinity.
Inspect components d/s of valve CD-05.1B-05V. Inspect pipe & elbow. Inspect two pipe 32 FT ELEV. OFF 35B FWH D/S OF 14              CD-05.1B-07E      183304        00217596    diameters =28 inches plus elbows & 3 inches                                        Y  Y  N  Y  EC-H-50064        14" VALVE CD-18-2 D/S of elbow weld. Inspect 6P/7E/8P                                                                                                CALCULATION RE-INSPECTION-FAC TOGETHER                                                                                                                          MANAGER -
Inspect components d/s of valve CD-05.1B-05V. Inspect pipe & elbow. Inspect two pipe 32 FT ELEV. OFF 35B FWH D/S OF 15              CD-05.1B-08P      183304        00217596    diameters =28 inches plus elbows & 3 inches                                        Y  Y  N  Y  EC-H-50064        14" VALVE CD-18-2 D/S of elbow weld. Inspect 6P/7E/8P                                                                                                CALCULATION RE-INSPECTION-FAC TOGETHER                                                                                                                          MANAGER -
Inspect reducing elbow (24x20) and pipe.
Inspect pipe and elbow plus upstream and 16              CD-02.4-4E        183307        00217597    downstream extension. Inspect 48" of pipe and ELEV. 24FT.6 ins. D/S OF TCV-1110    Y  Y  N  Y  EC-H-50061        24X20 Elbow plus 6 inches on either side of elbow                                                                                        CALCULATION RE-INSPECTION-FAC welds.Inspect 4E/1P TOGETHER                                                                                                      MANAGER -
Inspect reducing elbow (24x20) and pipe.
Inspect pipe and elbow plus upstream and 17              CD-02.5-01P      183307        00217597    downstream extension. Inspect 48" of pipe and ELEV. 24FT.6 ins. D/S OF TCV-1110    Y  Y  N  Y  EC-H-50064        24 Elbow plus 6 inches on either side of elbow                                                                                        CHECWORKS - Ranked high on the welds.Inspect 4E/1P TOGETHER                                                                                                      Service Life Report Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH 18              CD-02.3-15T      183309        00217599                                                  ELEV. 24FT.6 ins. U/S OF TCV-1110  Y  Y  N  Y  EC-H-50061        24x18 PLUS 12 INCHES ON ALL SIDES OF TEE                                                                                                CHECWORKS - Ranked high on the welds.                                                                                                                            Service Life Report 19              CD-02.8A-08N      183310        00217600    Inspect piping                                ELEV.39FT OFF FWH 33A              Y  Y  N  Y  EC-H-50061        14"          CHECWORKS - Ranked high on the Service Life Report 2 of 18                                                                                  3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                  SC  AF                        G            SI                            KS R              IN        R OR EQ K                O                              TI O                              AT            IN SU FO LD                IN              ZE                    R M                      T                            R                                  N                                IO                LA                AW                                          EM N                                  UES          K                                                                          N PA IN  TI ON                            PI U              EX                    T      W                              DES T              DR                  PE                          AR AM                          O                                                                    LO                PIPE  PR R                                C                                    C                        EP Inspect piping D/S of valve CD-16. Inspect ELBOW,PIPE,ELBOW &                          ELEV 34 FT. 8 INS. UPSTREAM OF 20              CD-02.8B-08N      183317        00217602                                                                                    Y  Y  N  Y  EC-H-50061        14" NOZZLE.(Components CD-02.8B-05E /06P        FWH 33B & D/S OF VALVE CD-16                                                      CHECWORKS - Ranked high on the
                                                            /07E/ 08N)                                                                                                                      Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW &                          ELEV 34 FT. 8 INS. UPSTREAM OF 21              CD-02.8B-05E      183317        00217602                                                                                    Y  Y  N  Y  EC-H-50061        14" NOZZLE.(Components CD-02.8B-05E /06P        FWH 33B & D/S OF VALVE CD-16 CHECWORKS - Ranked high on the
                                                            /07E/ 08N)
Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW &                          ELEV 34 FT. 8 INS. UPSTREAM OF 22              CD-02.8B-06P      183317        00217602                                                                                    Y  Y  N  Y  EC-H-50061        14" NOZZLE.(Components CD-02.8B-05E /06P        FWH 33B & D/S OF VALVE CD-16                                                      CHECWORKS - Ranked high on the
                                                            /07E/ 08N)                                                                                                                      Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW &                          ELEV 34 FT. 8 INS. UPSTREAM OF 23              CD-02.8B-07E      183317        00217602                                                                                    Y  Y  N  Y  EC-H-50061        14" NOZZLE.(Components CD-02.8B-05E /06P        FWH 33B & D/S OF VALVE CD-16                                                      CHECWORKS - Ranked high on the
                                                            /07E/ 08N)                                                                                                                      Service Life Report Inspect elbow plus upstream & downstream ELEV 34 FT. 8 INS. UPSTREAM OF 24              CD-02.8B-02E      183318        00217603    extension. Elbow plus 3 inches on either side                                  Y  Y  N  N  EC-H-50061        14" FWH 33B & U/S OF VALVE CD-16                                                      CALCULATION RE-INSPECTION-FAC of the elbow welds.
MANAGER -Last Inspected 2007 Inspect Pipe, elbow & Pipe. Inspect 28 inches ELEV 34 FT. 8 INS. UPSTREAM OF 25              CD-02.8C-02E      183319        00217333    of pipe. Inspect components CD-02.8C-                                          Y  Y  N  N  EC-H-50061        14" FWH 33C & U/S OF VALVE CD-16 01P/02.8C-02E/ 02.8C-3E TOGETHER.                                                                                              CALCULATION RE-INSPECTION-FAC MANAGER - Last Inspected 2007 Inspect elbow & Pipe. Inspect 28 inches of pipe plus elbow and 3 inches on the upstream ELEV 34 FT. 8 INS. UPSTREAM OF 26              CD-02.8C-03P      183319        00217333                                                                                    Y  Y  N  N  EC-H-50061        14" extension of the elbow. Inspect components  FWH 33C & U/S OF VALVE CD-16 RE-INSPECTION (TRENDING) last 02.8C-02E/ 02.8C-3E TOGETHER.
inspected 2007 with 02.8C-2E Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          ELEV. 24FT 6 INS. OFF 35A FWH TO 27              CD-06.1-01T      183320        00217604                                                                                    Y  Y  N  N  EC-H-50064        30X16 PLUS 12 INCHES ON ALL SIDES OF TEE          BFP #32                                                                            CALCULATION RE-INSPECTION-FAC welds.                                                                                                                          MANAGER - Last Inspected 1997 Inspect elbow plus upstream & downstream ELEV 32 FT. 0 INS. UPSTREAM OF 28              CD-06.2A-02E      183321        00217605    extension. Elbow plus 12 inches on either side                                  Y  Y  N  N  EC-H-50064        24"          CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 of the elbow welds.                                                                                                            MANAGER - last inspection 1992 ELEV 32 FT. 0 INS. DOWNSTREAM OF 29              CD-06.2A-08P      183322        00217607    Inspect piping 2 diameters = 48 inches.                                        Y  Y  N  N  EC-H-50064        24"          CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 MANAGER -
3 of 18                                                                                3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                      R BE                PO          W                    D                          IP                                                        SC  AF                        G              SI                              KS R                  IN        R OR EQ K                O                                TI O                                  AT                IN SU FO LD                IN                ZE                      R M                          T                            R                                  N                                    IO                  LA                AW                                              EM N                                      UES            K                                                                            N PA IN  TI ON                            PI U                EX                    T      W                                DES T              DR                    PE                            AR AM                          O                                                                          LO                  PIPE  PR R                                C                                        C                          EP Inspect elbow plus upstream & downstream ELEV 24 FT. 6 INS. DOWNSTREAM OF 30                CD-06.2A-011E      183324        217606      extension. Elbow plus 12 inches on either side                                        Y  Y  N  N  EC-H-50064          24"          CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 of the elbow welds.                                                                                                                    MANAGER -
31                CD-02.12-05P      183331        00217620    Inspect piping 2 diameters = 36 inches.      D/S OF VALVE CD-15 (CD-02.12-04V)        Y  Y  N  N  EC-H-50088          18"          CALCULATION RE-INSPECTION-FAC MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          ELEV 32 FT. 0 INS. UPSTREAM OF 32                  CD-02.6-3T      183332        00217612                                                                                            Y  Y  N  N  EC-H-50061        24x14 PLUS 12 INCHES ON ALL SIDES OF TEE            FWH 33B & U/S OF VALVE CD-16                                                              CALCULATION RE-INSPECTION-FAC welds.                                                                                                                                  MANAGER -
Inspect back to back elbows. Inspect elbows Plus U/S and D/S extensions ~ 3 inches on 33                CD-04.1C-02E      183333        00217621                                                  ELEV 41 FT. 0 INS. OFF FWH 34C.          Y  Y  N  N  EC-H-50062          14" either side of elbows.(CD-04.1C-02E &3E)                                                                                                CALCULATION RE-INSPECTION-FAC TOGETHER                                                                                                                                MANAGER -
Inspect back to back elbows. Inspect elbows Plus U/S and D/S extensions ~ 3 inches on 34                CD-04.1C-03E      183333        00217621                                                  ELEV 41 FT. 0 INS. OFF FWH 34C.          Y  Y  N  N  EC-H-50062          14" either side of elbows.(CD-04.1C-02E &3E)                                                                                                CALCULATION RE-INSPECTION-FAC TOGETHER                                                                                                                                MANAGER -
EXTRACTION ELEV. 39FT. 6 INS U/S OF VALVE 6EX-                                                      Inspected in 1997. Re-inspection or NSI =
35                EX-01.2-10L      183365        00217622    INSPECT LATERAL                                                                        Y  Y  N  N  EC-H-50000        18"X12"        3R16. CALCULATION RE-INSPECTION-1 & 6 EX-4 FAC MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          ELEV. 31FT. 9 INS U/S OF LINE TO 36                EX-01.4-02T      183367        00217624                                                                                            Y  Y  N  N  EC-H-50000        18X12 PLUS 3 INCHES ON ALL SIDES OF TEE            FWH 36B &VALVE 6EX-5.                                                                    CALCULATION RE-INSPECTION-FAC welds.                                                                                                                                  MANAGER -
37                EX-02.2-01N      183368        00217625    Inspect nozzle                                TB. ELEV.44FT. 5 INS                                N  EC-H-50071          10"          CALCULATION RE-INSPECTION-FAC MANAGER -
Elbow and UPSM and DNSM extensions.
Turb. Bldg. Elev. 24'-6" U/S of hanger 38                EX-02.14-25E      183370        00217627    Prep. Elbow plus 12 inches U/S & D/S of                                                Y  Y  Y  N  EC-H-50001          28"          CALCULATION RE-INSPECTION-FAC 5EX-6 elbow welds.                                                                                                                            MANAGER -
Inspect Elbow, Pipe, Inspect COMPONENTS                                                                                                Inspect CHECWORKS Components EX-D/S OF VALVE 5EX-5 COMPONENTS EX-                                                                                                      02.17-2V (Ranked high on the Service EX-02.17-02V 39                                  183371        00217628    02.17-03E/04P. FOR PIPE 2 DIA=36 INCHES. Turb. Bldg. Elev. 42'-3" off FWH 35B          Y  Y  Y  Y  EC-H-50001          18"          Life Report). Components D/S of valve D/S = EX-02.17-03E Also inspect u/s extension of first elbow 8                                                                                            selected since valves are rarely UT inches(d/s of valve)                                                                                                                    INSPECTED DUE TO CONTOUR.
4 of 18                                                                                          3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                          SC  AF                        G            SI                              KS R              IN        R OR EQ K                O                              TI O                                AT                  IN SU FO LD                IN              ZE                      R M                      T                            R                                  N                                  IO                      LA                AW                                            EM N                                  UES          K                                                                            N PA IN  TI ON                            PI U              EX                    T      W                              DES T              DR                  PE                            AR AM                          O                                                                        LO                      PIPE  PR R                                C                                        C                              EP Inspect Elbow, Pipe, . Inspect COMPONENTS D/S OF VALVE 5EX-5 COMPONENTS EX-Component also selected because of 40              EX-02.17-04P      183372        00217628    02.17-03E/04P. FOR PIPE 2 DIA=36 INCHES. Turb. Bldg. Elev. 42'-3" off FWH 35B            Y  Y  Y  Y  EC-H-50001        18" proximity to highly ranked component.
Also inspect u/s extension of first elbow 8 inches(d/s of valve)
Elbow and UPSM and DNSM extensions.
41              EX-03.1B-33E      183377        00217631    Prep. Elbow plus 10 inches U/S & D/S of    Turb. Bldg. Elev. 42'-2" off FWH 34B        Y  Y  N  N  EC-H-50006        20"          CALCULATION RE-INSPECTION-FAC elbow welds.                                                                                                                            MANAGER -
Elbow and UPSM and DNSM extensions.
42              EX-03.1C-37E      183379        00217634    Prep. Elbow plus 10 inches U/S & D/S of    Turb. Bldg. Elev. 42'-2" off FWH 34C        Y  Y  N  N  EC-H-50002        20"          CALCULATION RE-INSPECTION-FAC elbow welds.                                                                                                                            MANAGER -
Inspect reducer plus U/S & D/S EXTENSION 6 Turb. Bldg. Elev. 24'-6" U/S of hanger 43                                183380        00217635                                                                                            Y  Y  N  N  EC-H-50008        28X20        CALCULATION RE-INSPECTION-FAC
                                                            " ON EITHER SIDE OF WELD.                  3EX-23. LINE OFF 33B FWH EX-04.13-01R                                                                                                                                                                        MANAGER -
Inspect PIPE &ELBOW. (EX-04..6-04P/05E) 44                                183382        00217639                                                Turb. Bldg. Elev. 42'-2" off FWH 33A        Y  Y  N  N  EC-H-50007        20"          CALCULATION RE-INSPECTION-FAC For piping INSPECT 2 diameters = 40 inches.
EX-04..6-04P                                                                                                                                                                        MANAGER -
Inspect PIPE & ELBOW. (EX-04..6-04P/05E) 45                                183382        00217639    For piping INSPECT 2 diameters = 40 inches. Turb. Bldg. Elev. 42'-2" off FWH 33A        Y  Y  N  N  EC-H-50007        20" Also inspect downstream extension of elbow.                                                                                              CALCULATION RE-INSPECTION-FAC EX-04..6-05E                                                                                                                                                                        MANAGER -
Turb. Bldg. between Elev. 24'-2" & 42'-2".
46                                183383        00217640    Inspect piping 2 diameters = 40 inches.                                                  Y  Y  N  N  EC-H-50007        20"          CALCULATION RE-INSPECTION-FAC Line OFF 33A FWH EX-04.7-01P                                                                                                                                                                          MANAGER -
FEEDWATER Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH TB. ELEV. 24'-5" D/S OF BFP 31 47              FW-01.2A-03T      183385        00217641    PLUS 10 INCHES ON ALL SIDES OF TEE                                                      Y  Y  N  N  EC-H-50039        20"X 6" DISCHARGE.
MAIN welds PLUD 2 INCHES D/S OF CALCULATION RE-INSPECTION-FAC BRANCH..
MANAGER -
Elbow and UPSM and DNSM extensions.        TB. ELEV. 24'-5" D/S OF BFP 31 48              FW-01.2A-10E      183386        00217662    Prep. Elbow plus 10 inches U/S & D/S of    DISCHARGE & FURTHER D/S OF                    Y  Y  N  N  EC-H-50039        20"          CALCULATION RE-INSPECTION-FAC elbow welds.                              VALVE BFD2-3.                                                                                MANAGER -
TB. ELEV. 24'-5" D/S OF BFP 31 49              FW-01.2A-23P      183387        00217663    Inspect piping 2 diameters = 40 inches. DISCHARGE & FURTHER D/S OF                    Y  Y  N  N  EC-H-50039        20"          CALCULATION RE-INSPECTION-FAC HANGER BFD-11                                                                                MANAGER -
TB. ELEV. 24'-5" D/S OF BFP Inspect reducer plus U/S & D/S EXTENSION 6 50              FW-01.2B-27R      183388        00217664                                              32DISCHARGE & FURTHER D/S OF                  Y  Y  N  N  EC-H-50039        30X20        CALCULATION RE-INSPECTION-FAC
                                                            " ON EITHER SIDE OF WELD.
HANGER BFD-6.                                                                                MANAGER -
5 of 18                                                                                            3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                    SC  AF                        G            SI                          KS R              IN        R OR EQ K                O                              TI O                              AT                IN SU FO LD                IN              ZE                  R M                      T                            R                                  N                                IO                  LA                AW                                          EM N                                  UES          K                                                                          N PA IN  TI ON                            PI U              EX                    T      W                              DES T              DR                  PE                        AR AM                          O                                                                    LO                  PIPE  PR R                                C                                    C                          EP Elbow and UPSM and DNSM extensions.
Turb. Bldg. Elev. 23'-6" D/S of hanger 51              FW-01.3-15E      183389        00217665    Prep. Elbow plus 12 inches U/S & D/S of                                            Y  Y  N  N  EC-H-50039        30"          CALCULATION RE-INSPECTION-FAC BFD-16. LINE OFF FWH 36A elbow welds.                                                                                                                      MANAGER -
Turb. Bldg. Elev. 34'-9" D/S OF VALVE 52              FW-02.1C-10P      183394        00217672    Inspect piping 2 diameters = 36 inches.                                            Y  Y  N  N  EC-H-50042        18"          CALCULATION RE-INSPECTION-FAC BFD-4 =. LINE OFF FWH 36C MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH      Turb. Bldg. Elev. 34'-9" D/S OF VALVE 53              FW-02.1C-11T      183395        00217673                                                                                      Y  Y  N  N  EC-H-50042        30X18 PLUS 12 INCHES ON ALL SIDES OF TEE        BFD-4 =. LINE OFF FWH 36C                                                                CALCULATION RE-INSPECTION-FAC welds.                                                                                                                            MANAGER -
Elbow and UPSM and DNSM extensions.      Turb. Bldg. Elev. 29'-9" D/S OF 54              FW-02.4-05E      183396        00217700    Prep. Elbow plus 12 inches U/S & D/S of  HANGER BFD-22 =. LINE OFF FWH            Y  Y  N  N  EC-H-50039        30"          CALCULATION RE-INSPECTION-FAC elbow welds.                              36A                                                                                      MANAGER -
6 of 18                                                                                      3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE                PO            W                    D                          IP                                                      SC  AF                          G            SI                            KS R                  IN        R OR EQ K                O                              TI O                                AT              IN SU FO LD                  IN              ZE                    R M                          T                              R                                  N                                  IO                LA                  AW                                          EM N                                      UES          K                                                                            N PA IN  TI ON                              PI U                  EX                    T      W                              DES T                  DR                  PE                          AR AM                          O                                                                        LO                PIPE  PR R                                C                                        C                        EP Inspect PIPE & ELBOW. (FW-02.4-07E/08P)
AUX. Bldg. Elev. 29'-9" D/S OF For piping INSPECT 2 diameters = 60 inches.
55                FW-02.4-07E        183397        00217699                                                HANGER BFD-22 =. LINE OFF FWH          Y  Y  N  Y    EC-H-50040        30" PLUS U/S EXTENSION OF ELBOW =12                                                                                                      CHECWORKS - Ranked high on the 36A INCHES                                                                                                                                Service Life Report Inspect PIPE & ELBOW. (FW-02.4-07E/08P)
AUX. Bldg. Elev. 29'-9" D/S OF For piping INSPECT 2 diameters = 60 inches.
56                FW-02.4-08P        183397        00217699                                                HANGER BFD-22 =. LINE OFF FWH          Y  Y  N  Y    EC-H-50040        30" PLUS U/S EXTENSION OF ELBOW =12                                                                                                      CHECWORKS - Ranked high on the 36A INCHES                                                                                                                                Service Life Report Inspect PIPE, ELBOW& PIPE. (FW-02.4-12P/13E/14P) For piping INSPECT 2            AUX. Bldg. Elev. 29'-9" D/S OF 57                FW-02.4-13E        183398        00217697                                                                                        Y  Y  N  Y    EC-H-50040        30" diameters = 60 inches. PLUS U/S              HANGER BFD-25. LINE OFF FWH 36A                                                        CHECWORKS - Ranked high on the EXTENSION OF ELBOW =12 INCHES                                                                                                        Service Life Report Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          AUX. Bldg. Elev. 43'-0" D/S OF 58                FW-02.4-19T        183399        00217696                                                                                        Y  Y  N  N    EC-H-50040        30X18 PLUS 12 INCHES ON ALL SIDES OF TEE            HANGER BFD-32. LINE OFF FWH 36A                                                        CALCULATION RE-INSPECTION-FAC welds.                                                                                                                                MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          AUX. Bldg. Elev. 43'-0" U/S OF                        EC-H-50040/9321-59              FW-02.6-02T (Elbow)  183400        00217695    PLUS 12 INCHES ON ALL SIDES OF TEE                                                  Y  Y  N  Y                      30X6 HANGER BFD-33. LINE OFF FWH 36A                          F-20613                      CHECWORKS - Ranked high on the welds. NOTE this really an elbow attached and not a tee.                                                                                                                            Service Life Report Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH AUX. Bldg. Elev. 43'-0" U/S OF                        EC-H-50040/9321-60              FW-02.7-02T (Elbow)  183401        00217694    PLUS 12 INCHES ON ALL SIDES OF TEE                                                  Y  Y  N  Y                      30X6 HANGER BFD-33. LINE OFF FWH 36A                          F-20613 welds. NOTE this really an elbow attached and                                                                                        CHECWORKS - Ranked high on the not a tee.                                                                                                                            Service Life Report Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH          AUX. Bldg. Elev. 43'-0" D/S OF 61                  FW-02.7-4T        183402        00217693                                                                                        Y  Y  N  N    EC-H-50040        30X18 PLUS 12 INCHES ON ALL SIDES OF TEE            HANGER BFD-33. LINE OFF FWH 36A                                                        CALCULATION RE-INSPECTION-FAC welds.                                                                                                                                MANAGER -
Reducer and UPSM and DNSM extensions.
AUX. BLDG. Elev 22'-3" adjacent to 62                FW-02.8A-26R        183405        00217690    Prep. reducer plus 8 inches of piping U/S &                                        Y  Y  N  N    EC-H-50040        18" FCV-417 D/S                                                                            CALCULATION RE-INSPECTION-FAC D/S of reducer welds.
MANAGER -
AUX. Bldg. BETWEEN ELEV. 43'-0"& 22 63                FW-02.8B-01P        183406        00217689    Inspect piping 2 diameters = 36 inches.                                            Y  Y  N  N    EC-H-50040        18"          CALCULATION RE-INSPECTION-FAC FT 3 INS U/S OF VALVE FCV-427 MANAGER -
Reducer and UPSM and DNSM extensions.
AUX. BLDG. Elev 22'-3" adjacent to 64                FW-02.8B-25R        183407        00217688    Prep. reducer plus 8 inches of piping U/S &                                        Y  Y  N  N    EC-H-50040        18" BFD-MOV-5-2                                                                            CALCULATION RE-INSPECTION-FAC D/S of reducer welds.
MANAGER -
7 of 18                                                                                      3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                        SC  AF                        G            SI                              KS R              IN        R OR EQ K                O                              TI O                                AT                IN SU FO LD                IN              ZE                      R M                      T                            R                                  N                                  IO                  LA                AW                                            EM N                                  UES          K                                                                            N PA IN  TI ON                          PI U              EX                    T      W                              DES T              DR                  PE                            AR AM                          O                                                                        LO                  PIPE  PR R                                C                                        C                          EP AUX. BLDG. Elev 57'-6" adjacent to BFD-65              FW-02.8C-20P      183409        00217685    Inspect piping 2 diameters = 36 inches.                                              Y  Y  N  Y  EC-H-50041        18"          CHECWORKS - Ranked high on the 7-4 Service Life Report Reducer and UPSM and DNSM extensions.
AUX. BLDG. Elev 22'-3" adjacent to 66              FW-02.8C-25R      183410        00217684    Prep. reducer plus 8 inches of piping U/S &                                          Y    Y  N  N  EC-H-50040        18"          CALCULATION RE-INSPECTION-FAC FCV-447 D/S D/S of reducer welds.                                                                                                                MANAGER -
Inspect CHECWORKS Components FW-02.1B-5V (Ranked high on the Service Inspect components D/S ov valve FW-02.8d-Life Report). Components D/S of valve 05V. Elbow and PIPE. Prep. 2 DIA =36" for    AUX. BLDG. Elev 22'-3" adjacent to 67              FW-02.8D-07E      183413        00217682                                                                                        Y    Y  N  Y  EC-H-50040        18"          selected since valves are rarely UT pipe and Elbow plus 8 inches D/S of elbow    FCV-437 D/S INSPECTED DUE TO CONTOUR. Other weld. FW-02.8D-07E/8P component selected in close proximity to highly ranked component.
Elbow and PIPE. Prep. 2 DIA =36" for pipe AUX. BLDG. Elev 22'-3" adjacent to                                                    CHECWORKS - Ranked high on the 68              FW-02.8D-08P      183413        00217682    and Elbow plus 8 inches D/S of elbow weld.                                          Y    Y  N  Y  EC-H-50040        18" FCV-437 D/S                                                                            Service Life Report AND IN VECINITY OF FW-02.8D-07E/8P OTHER SELECTED COMPONENTS.
8 of 18                                                                                      3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                      R BE              PO          W                    D                            IP                                                      SC  AF                        G              SI                            KS R                IN        R OR EQ K                O                                TI O                                AT                IN SU FO LD                IN                ZE                    R M                        T                            R                                    N                                  IO                  LA                AW                                            EM N                                    UES          K                                                                              N PA IN  TI ON                            PI U              EX                    T      W                                DES T              DR                    PE                          AR AM                          O                                                                        LO                  PIPE  PR R                                C                                        C                          EP AUX. BLDG. Elev 57'-6" adjacent to BFD-69              FW-02.8D-19P      183414        00217680    Inspect piping 2 diameters = 36 inches.                                                Y  Y  N  Y  EC-H-50041          18"          CHECWORKS - Ranked high on the 7-3 Service Life Report AUX. BLDG. Elev 22'-3" adjacent to 70              FW-02.8D-24R      183415        00217681    INSPECT REDUCER                                                                      Y    Y  N  Y  EC-H-50040        18"X12"        CALCULATION RE-INSPECTION-FAC FCV-437 D/S MANAGER -
Elbow and UPSM and DNSM extensions.          VC ELEV. 104'-10". Line to 34 Steam 71              FW-03.1C-14E      183418        00217678    Prep. Elbow plus 8 inches U/S & D/S of elbow generator                                Y    Y  N  N  EC-H-50046          18"          CALCULATION RE-INSPECTION-FAC welds.                                                                                                                                  MANAGER -
TB ELEV. 24'-5"D/S OF 31BFP Inspect Elbow & Pipe. Inspect 2 dia = 12" of  DISCHARGE @ COMPONENT FW-72              FW-04.1A-01E      183421        00217677                                                                                          Y    Y  N  N  EC-H-50084          6"          CALCULATION RE-INSPECTION-FAC pipe plus elbow                                01.2A-3T                                                                                MANAGER -
HEATER DRAINS Inspect reducer plus U/S & D/S EXTENSION 6 73              HD-09.1A-02R      183427        00217412                                              TB ELEV 38'- 3" D/S OF LCV 1121            Y    Y  N  N  EC-H-50031        12"X10"
                                                            " ON EITHER SIDE OF WELD IF POSSIBLE..                                                                                                  CALCULATION RE-INSPECTION-FAC MANAGER -
Inspect CHECWORKS Components HD-11.1A-02V (Ranked high on the Service HD-11.1A-02V                                Inspect reducer plus U/S & D/S EXTENSION 6 TB. ELEV 15 FT D/S OF HTR DRAIN 74                                183428        00217413                                                                                          Y    Y  N  Y  EC-H-50079        12"x8"        Life Report). Components D/S of valve (HD-11.2A-01R)                              " ON EITHER SIDE OF WELD IF POSSIBLE.. PUMP 31 AND VALVE HD-1 selected since valves are rarely UT INSPECTED DUE TO CONTOUR.
Inspect CHECWORKS Components HD-11.1B-02V (Ranked high on the Service Inspect reducer plus U/S & D/S EXTENSION 6 TB. ELEV 15 FT D/S OF HTR DRAIN 75              HD-11.2B-01R      183429        00217408                                                                                          Y    Y  N  Y  EC-H-50079        12"x8"        Life Report). Components D/S of valve
                                                            " ON EITHER SIDE OF WELD IF POSSIBLE.. PUMP 32 AND VALVE HD-1 selected since valves are rarely UT INSPECTED DUE TO CONTOUR.
Inspect CHECWORKS Components HD-12.1A-01V (Ranked high on the Service Inspect component d/s of valve HD-2            TB. ELEV 15 FT D/S OF HTR DRAIN 76                                183431        00217406                                                                                                          EC-H-50079          12"          Life Report). Components D/S of valve component HD-12.2A-03E.                        PUMP 31 AND VALVE HD-1 selected since valves are rarely UT HD-12.2A-03E                                                                                                                                                                        INSPECTED DUE TO CONTOUR.
TB. ELEV 15 FT D/S OF HTR DRAIN 77                                183433        00217403    Inspect 2 dia = 24 inches d/s of orifice                                              Y    Y  N  Y  EC-H-50079          12" PUMP 32 AND VALVE HD-1                                                                  CALCULATION RE-INSPECTION-FAC HD-12.2B-06O                                                                                                                                                                        MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH            TB. ELEV 15 FT D/S OF HTR DRAIN 78                                183434        00217404                                                                                          Y    Y  N  Y  EC-H-50079          12" PLUS 6 INCHES ON ALL SIDES OF TEE              PUMP 32 AND VALVE HD-1                                                                  CALCULATION RE-INSPECTION-FAC HD-12.2B-08T                                welds.                                                                                                                                  MANAGER -
9 of 18                                                                                        3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE                PO          W                    D                          IP                                              SC  AF                          G            SI                          KS R                  IN        R OR EQ K                O                              TI O                          AT            IN SU FO LD                  IN              ZE                  R M                          T                            R                                  N                            IO                LA                  AW                                        EM N                                      UES          K                                                                      N PA IN  TI ON                            PI U              EX                      T      W                              DES T                DR                  PE                        AR AM                            O                                                                  LO                PIPE  PR R                                C                                  C                        EP TB. ELEV 32' 0" D/S OF HTR DRAIN 79              HD-12.3-01P        183435        00217396    Inspect piping 2 diameters = 32 inches.                                      Y  Y  N  N    EC-H-50079        16" PUMP 32.                                                                            CALCULATION RE-INSPECTION-FAC MANAGER -
Rre-inspect per data sheet 99UT261. Inspect 3 80                99-PT-29          183436        00217402                                                  VENT CHAMBER DRAIN            Y  Y  N  N    9321-F-29013      3" elbows & 3 pipes.                                                                                                            CALCULATION RE-INSPECTION-Small Bore/ Augmented Program HEATER DRAIN TANK LARGE DUMP TO 33 Inspect puiping and fitting d/s of 5HD-81                                  183437        00217394                                                                                Y  Y  N  Y  EC-F-20223 SH-2    14" CONDENSER                          LCV-1127B                                                                                  LEAKS AFFECTING THERMAL 5HD-LCV-1127B                                                                                                                                                                EFFICIENCY HEATER DRAIN TANK LARGE DUMP TO 32 Inspect puiping and fitting d/s of 5HD-82                                  183438        00217395                                                                                Y  Y  N  Y  EC-F-20223 SH-2    14" CONDENSER                          LCV-1127C                                                                                  LEAKS AFFECTING THERMAL 5HD-LCV-1127C                                                                                                                                                                EFFICIENCY 10 of 18                                                                                3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                      SC  AF                        G          SI                              KS R              IN      R OR EQ K                O                              TI O                                    AT          IN SU FO LD                IN            ZE                      R M                      T                            R                                  N                                      IO              LA                AW                                          EM N                                  UES            K                                                                              N PA IN  TI ON                          PI U              EX                  T      W                              DES T              DR                PE                            AR AM                        O                                                                          LO              PIPE  PR R                                C                                          C                      EP RE-HEATER DRAINS tb-elev. 46'-0" d/s of FE-1257-3 Re-Inspect piping D/S OF FE1257-3 (includes straight pipe expander and elbow RHD01.10A-83              RHD01.10A-18F    183739      217723                                                                                                          EC-H-50014        6" 18F/20R&RHD01.11A-01E). last inspected 2005 reference datasheet 05UT077.                                                                                                CALCULATION RE-INSPECTION-FAC Y  Y  N  N                                MANAGER -
TB. ELEV 56'-4" OFF REHEATER Inspect nozzle, pipe & elbow (RHD01.10A-DRAIN TANK 33A 84              RHD01.10A-04N    183740      00217711    04N/5P/6E. For pipe 2dia = 12 inches. Also                                                        EC-H-50014        6" CHECWORKS - Ranked high on the inspect d/s extension of elbow =2 insches Y  Y  N  Y                                Service Life Report TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.10A-DRAIN TANK 33A                                                                    Component also selected because of 85              RHD01.10A-05P    183740      00217711    04N/5P/6E. For pipe 2dia = 12 inches. Also                                                        EC-H-50014        6" proximity to highly ranked component.
inspect d/s extension of elbow =2 insches Y  Y  N  Y TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.10A-DRAIN TANK 33A                                                                    Component also selected because of 86              RHD01.10A-06E    183740      00217711    04N/5P/6E. For pipe 2dia = 12 inches. Also                                                        EC-H-50014        6" proximity to highly ranked component.
inspect d/s extension of elbow =2 insches Y  Y  N  Y TB. ELEV. 47'-7" D/S OF FLOW Re-Inspect piping D/S OF flow element. last 87              RHD01.10B-26F    183741      217712                                                  ELEMENT FE-1258-3. LINE OFF RHD                        EC-H-50016        6" inspected 2005 reference datasheet 05UT074.                                                                                      CALCULATION RE-INSPECTION-FAC TANK 33B Y  Y  N  N                                MANAGER -
RE-INPECT REDUCER . LAST INSPECTED            TB. ELEV. 38'-9" U/S OF VALVE LCV-88              RHD01.13A-01R    183745      00217713                                                                                                        EC-H-50014        6"          CALCULATION RE-INSPECTION-FAC 1999 REFERENCE DATA SHEET 99UT255            1104B Y  Y  N  N                                MANAGER -
TB. ELEV. 44'-8" D/S OF FLOW INPECT 24" of piping U/S and D/S of flow 89              RHD01.1A-35F      183748      00217714                                                  ELEMENT FE-1257-1. LINE OFF RHD      Y  Y  N  N  EC-H-50011        6"          CALCULATION RE-INSPECTION-FAC element TANK 31A                                                                          MANAGER -
TB. ELEV 56'-4" OFF REHEATER Inspect nozzle , pipe & elbow (RHD01.3A-      DRAIN TANK 32A 90              RHD01.3A-04N      183749      00217715    04N/5P/6E. For pipe 2dia = 12 inches. Also                                        Y  Y  N  Y  EC-H-50012        6" inspect d/s extension of elbow =2 insches                                                                                        CHECWORKS - Ranked high on the Service Life Report Inspect nozzle , pipe & elbow (RHD01.3A-      TB. ELEV 56'-4" OFF REHEATER DRAIN TANK 32A                                                                    Component also selected because of 91              RHD01.3A-05P      183749      00217715    04N/5P/6E. For pipe 2dia = 12 inches. Also                                        Y  Y  N  Y  EC-H-50012        6" proximity to highly ranked component.
inspect d/s extension of elbow =2 insches TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.3A-DRAIN TANK 32A                                                                    Component also selected because of 92              RHD01.3A-06E      183749      00217715    04N/5P/6E. For pipe 2dia = 12 inches. Also                                        Y  Y  N  Y  EC-H-50012        6" proximity to highly ranked component.
inspect d/s extension of elbow =2 insches 11 of 18                                                                                  3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                R BE              PO          W                    D                      IP                                                  SC  AF                        G            SI                          KS R              IN      R OR EQ K                O                          TI O                            AT              IN SU FO LD                IN              ZE                  R M                      T                            R                            N                              IO                LA                AW                                        EM N                                  UES          K                                                                    N PA IN  TI ON                          PI U              EX                  T      W                          DES T              DR                  PE                        AR AM                        O                                                              LO                PIPE  PR R                          C                                    C                        EP TB. ELEV 49'-1" OFF REHEATER REINPECT (6") ELBOW & D/S PIPING. DRAIN TANK 32B 93              RHD01.3B-06E      183752      00217716                                                                              Y  Y  N  N  EC-H-50009        6"          CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET 99UT251.
MANAGER -
INPECT U/S & D/S OF FLOW ELEMENT FE- TB. ELEV. 47'-10" D/S OF FLOW 94              RHD01.5B-03F      183754      00217717    1257-2 ~ 2 DIA = 12" ON EITHER SIDE OF ELEMENT FE-1258-2. LINE OFF RHD    Y  Y  N  N  EC-H-50009        6"          CALCULATION RE-INSPECTION-FAC ELEMENT.                              TANK 32B                                                                          MANAGER -
REINPECT EXPANDER PER DATA SHEET      TB. ELEV. 47'-8" U/S OF VALVE LCV-95              RHD01.7B-03R      183758      00217719                                                                              Y  Y  N  N  EC-H-50009        10X6        CALCULATION RE-INSPECTION-99UT277.                              1105A TRENDING DATABASE Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH PLUS 4 INCHES ON ALL SIDES OF TEE  TB. ELEV. 31'-8" D/S OF VALVE RHD-2.
96              RHD02.10A-11T    183760      00217704                                                                              Y  Y  N  N  EC-H-50015        8X6 MAIN welds PLUS 2 INCHES D/S OF    LINE OFF FWH 36B BRANCH.. REFERENCE DATASHEET 3R14-                                                                                        CALCULATION RE-INSPECTION-FAC FAC-07-062                                                                                                                MANAGER -
12 of 18                                                                                3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                        SC  AF                        G            SI                          KS R              IN      R OR EQ K                O                              TI O                                  AT                IN SU FO LD                IN              ZE                  R M                      T                            R                                  N                                    IO                  LA                AW                                        EM N                                  UES            K                                                                            N PA IN  TI ON                          PI U              EX                  T      W                              DES T              DR                  PE                        AR AM                        O                                                                        LO                  PIPE  PR R                                C                                        C                          EP Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH PLUS 2 INCHES ON ALL SIDES OF TEE  TB. ELEV. 39'-3" U/S OF VALVE RHD-1.
97              RHD02.12B-11T    183763      00217705                                                                                          Y  Y  N  N  EC-H-50010 MAIN welds PLUS 2 INCHES D/S OF    LINE OFF FWH 36B BRANCH.REFERENCE DATA SHEETS 3R15-                                                                                                  CALCULATION RE-INSPECTION-FAC FAC-09-158/159.                                                                                                        6X6          MANAGER -
Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH PLUS 2 INCHES ON ALL SIDES OF TEE  TB. ELEV. 42'-9" D/S OF VALVE RHD-1.
98              RHD02.13A-16T    183765      00217706                                                                                          Y  Y  N  N  EC-H-50015        6X6 MAIN welds PLUS 2 INCHES D/S OF    LINE OFF FWH 36B BRANCH.REFERENCE DATA SHEET 3R15-CALCULATION RE-INSPECTION-FAC FAC-09-028.
MANAGER -
Inspect PUP PIPING U/S OF Nozzle.
TB. ELEV. 42'-9" D/S OF VALVE RHD-1.
99              RHD02.14A-01N    183769      00217707    REFREENCE DATA SHEET 3R14-FAC                                                    Y  Y  N  N  EC-H-50015        8"          CALCULATION RE-INSPECTION-FAC LINE OFF FWH 36B 058.                                                                                                                                MANAGER -
INSPECT EXPANDER . REFERENCE DATA TB. ELEV. 38'-9" D/S OF VALVE LCV-100              RHD02.3A-02R      183787      00217709                                                                                          Y  Y  N  N  EC-H-50015        4X6"        CALCULATION RE-INSPECTION-FAC SHEET 3R14-FAC-07-054            1104A MANAGER -
INSPECT EXPANDER . REFERENCE DATA TB. ELEV. 38'-9" D/S OF VALVE LCV-101              RHD02.5A-02R      183790      00217710                                                                                          Y  Y  N  N  EC-H-50015        4X6"        CALCULATION RE-INSPECTION-FAC SHEET 3R14-FAC-07-016            1104B MANAGER -
MSR DRAINS TB. ELEV. 21'-6" AT HEATER DRAIN TANK 102              MSD-01.10A-25N    183806      00217929    Inspect nozzle                                                                        Y  Y  N  N  EC-H-50035        6" CALCULATION RE-INSPECTION-FAC MANAGER -
TB. ELEV 43'-6" BELOW MSR DRAIN 103              MSD-01.10B-02E    183807      00217930    Inspect elbow. Reference data sheet 99UT283 TANK 32B                                  Y  Y  N  N  EC-H-50038        6"          CALCULATION RE-INSPECTION-FAC MANAGER -
TB. ELEV 39'-6" BELOW MSR DRAIN Elbow and UPSM and DNSM extensions.
TANK 32B & D/S OF VALVE 5-HD-2 104              MSD-01.10B-07E    183808      00217931    Prep. Elbow plus 2 inches U/S & D/S of elbow                                          Y  Y  N  N  EC-H-50038        6" CALCULATION RE-INSPECTION-FAC welds. Reference data sheet 99UT284 MANAGER -
Inspect TEE, BRANCH and upstream &            TB. ELEV 53'96" 33A MSR DRAIN U/S downstream extensions, TEE & BRANCH            OF VALVE 5HD-1.
105              MSD-01.13A-01T    183809      217932      PLUS 6 INCHES ON ALL SIDES OF TEE                                                    Y  Y  N  N  EC-H-50078        12" MAIN welds PLUS 6 INCHES D/S OF                                                                                                      CALCULATION RE-INSPECTION-FAC BRANCH..                                                                                                                            MANAGER -
13 of 18                                                                                  3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                          IP                                                        SC  AF                        G          SI                          KS R                IN      R OR EQ K                O                              TI O                                AT                  IN SU FO LD                IN              ZE                  R M                        T                            R                                  N                                  IO                    LA                AW                                        EM N                                  UES          K                                                                            N PA IN  TI ON                          PI U                EX                  T      W                              DES T                DR                PE                        AR AM                        O                                                                      LO                    PIPE  PR R                                C                                      C                            EP TB. ELEV 34'-0" BELOW MSR DRAIN Reinspect (6") piping .Inspected 1999.      TANK 31B & D/S OF VALVE 5-HD-3 106              MSD-01.5B-11P-2    183813      00217934                                                                                          Y  Y  N  N  EC-H-50038        6"          CALCULATION RE-INSPECTION-FAC Reference datasheet 99UT280 ~24 "
MANAGER -
3R14 EXAM. RE-INSPECT SEE DATA              Turbine Building. Located SHEET 3R14-FAC-07-104. Piping segments 107              FAC-07-VCD-05      183818      00217936 from MSR 32B. Two (2) 90 degree elbows per approximately 12' west and on the        Y  Y  N  N  9321-F-29013      3" CALCULATION RE-INSPECTION-FAC previous exam.                              centerline of F/19, El. 46'                                                              MANAGER -
3R14 EXAM. RE-INSPECT SEE DATA SHEET 3R14-FAC-07-055. EXAM CONSISTS        Turbine Building. Located approximately 108              FAC-07-VCD-07      183819      00217937                                                                                          Y  Y  N  N  9321-F-20233      3" OF ELBOW DOWNSTREAM OF VCD-2.                7' West and 4' North and F/17. El 53'                                                    CALCULATION RE-INSPECTION-FAC MSR 33B                                                                                                                              MANAGER -
3R14 EXAM. RE-INSPECT SEE DATA              TB EL 52'; VCD Discharge from MSR 109              FAC-07-VCD-09      183823      00217939                                                                                          Y  Y  N  N  9321-F-20233      3" SHEET 3R14-FAC-07-101                        31A                                                                                      CALCULATION RE-INSPECTION-FAC MANAGER -
TB EL 36' West of 33' mezz stairs; VCD 3R14 EXAM. RE-INSPECT SEE DATA Discharge from MSR 32A; 2 elbows 110              FAC-07-VCD-11      183828      00217940    SHEET 3R14-FAC-07-039/046. VCD                                                        Y  Y  N  N  9321-F-20233      3" CALCULATION RE-INSPECTION-FAC Discharge from MSR 32A; 2 elbows MANAGER -
14 of 18                                                                                    3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE              PO          W                    D                        IP                                                          SC  AF                        G              SI                          KS R                IN      R OR EQ K                O                              TI O                                  AT                IN SU FO LD                IN                ZE                  R M                        T                            R                                N                                    IO                    LA                AW                                          EM N                                  UES            K                                                                          N PA IN  TI ON                              PI U                EX                  T      W                              DES T                DR                    PE                        AR AM                        O                                                                        LO                    PIPE  PR R                              C                                        C                            EP 3R10 EXAM. RE-INSPECT SEE DATA              TB EL 47'-8" VCD Discharge from MSR 111                99-PT-25-2      183833      00217941                                                                                          Y  Y  N  N  9321-29013          3" SHEET 99UT258. VDC                          31A                                                                                        CALCULATION RE-INSPECTION-TRENDING DATABASE 3R10 EXAM. RE-INSPECT SEE DATA              TB EL 46'-3" VCD Discharge from MSR 112                99-PT-29-5      183837      00217942                                                                                          Y  Y  N  N  9321-29013          3" SHEET 99UT261. VDC                          31B                                                                                        CALCULATION RE-INSPECTION-TRENDING DATABASE TB. approximately 12' West and on the 3R12 EXAM. RE-INSPECT SEE DATA              centerline of F/19, El. 46'.
113                03-PT-06-03      183838      00217944                                                                                          Y  Y  N  N  9321-29013          3" SHEET 03UT073. HEATER DRAIN                                                                                                            CALCULATION RE-INSPECTION-TRENDING DATABASE TB. CONDENSER 31; 3' South and 3' 3R12 EXAM. RE-INSPECT SEE DATA              West of D6/15.7. From El. 36', 3' under 114              03-PT-04-02/03    183839      00217945                                                                                          Y  Y  N  N  9321-F-20233        3" SHEET 03UT019. HEATER DRAIN                grating                                                                                    CALCULATION RE-INSPECTION-TRENDING DATABASE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 31 B MSR NOZZLE AND SHELL          31B 115              MSD-01.3B-08N      183844      00217943                                                                                          Y  Y  N  Y  EC-H-50038          12" (MSD-01.3B-08N) .
OPERATING EXPERIENCE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 32 B MSR NOZZLE AND SHELL          32B 116              MSD-01.8B-08N      183845      00217946                                                                                          Y  Y  N  Y  EC-H-50038          12" (MSD-01.8B-08N) .
OPERATING EXPERIENCE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 33 B MSR NOZZLE AND SHELL          33B 117              MSD-01.13B-10N    183847      00217947                                                                                          Y  Y  N  Y  EC-H-50038          12" (MSD-01.13B-10N) .
OPERATING EXPERIENCE PRE-SEPARATOR DRAINS Inspect TEE, BRANCH and upstream &
downstream extensions, TEE & BRANCH 118              PD-02.3-01T      183848      00217948    PLUS 4 INCHES ON ALL SIDES OF TEE                                                    Y  Y  N  N                        16 MAIN welds PLUS 6 INCHES D/S OF            Turb Bldg. Elevation 16'-6"; Turb-Gen                                                      CALCULATION RE-INSPECTION-FAC BRANCH..                                    end.                                                      EC-H-50077                        MANAGER -
MAIN STEAM Main Steam Venturi from 33 SG. Inspect drain CONDITION REPORT-CR-IP3-2009-119                                183849      217950      slot area. Reference datasheet 3R15-FAC VC El 107'                                Y  Y  N  Y  9321-F-25423        28" 01453 MS-FE-439-DS                                117 Inspect main steam trap piping 120                01-PT-24-12      183851      00217951        segment 12(01-PT-24-12). Reference                                                Y  Y  N  N  9321-F-20423      3/4 & 1"      CALCULATION RE-INSPECTION-SNM data sheet 01UT037.                UPSTREAM OF VALVE MS-119-3                                                                        program 15 of 18                                                                                        3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                      R BE                PO          W                    D                            IP                                                        SC  AF                          G            SI                          KS R                IN        R OR EQ K                O                                TI O                                    AT              IN SU FO LD                  IN                ZE                  R M                        T                            R                                    N                                      IO                LA                    AW                                        EM N                                    UES          K                                                                                  N PA IN  TI ON                              PI U                EX                    T      W                                DES T                  DR                  PE                        AR AM                          O                                                                            LO                PIPE  PR R                                C                                            C                        EP Elbow and Piping DNSM of MS-FCV-1157 until it enters the condenser. 3R12EXAM. RE-121              03-PT-09-05/06/08  183852        00217952                                                                                            Y  Y  N  N    9321-F-20173      1.5"/2" INSPECT SEE DATA SHEET 03UT093.              TB . ELEV 31'-0" MEZZANNINE UNDER                                                              CALCULATION RE-INSPECTION-SNM extraction steam                            HP-TURBINE                                                                                    program 122              MS-FCV-1154        183854        00217953        32MSLine HP Turb. Drain to Cond.              TB . ELEV 31'-0" MEZZANNINE UNDER      Y  Y  N  Y    9321-F-20173        1"          PROBLEMS AFFECTING THERMAL HP-TURBINE                                                                                EFFICIENCY piping/fittings downstream of LCV-            32B moisture separator drain tank to                                                      PROBLEMS AFFECTING THERMAL 123                LCV-1109        183857        00217954                                                                                            Y  Y  N  Y    9321-F-20233        6" 1109                                          DCT                                                                                      EFFICIENCY FEEDWATER HEATER SHELLS Inspect FWH 31A shell. Inspect 2 pipe dia.
EC-F-20203/ 9321-124                                  132247        00155694    From center line of inlet nozzle (26") radially  Inside condenser #33                  Y  Y  N  Y                        Shell        OPERATING EXPERIENCE f-20053 FWH-31A HTX                                  and axially.
Inspect FWH 32B shell. Inspect 2 pipe dia.
EC-F-20203/ 9321-125                                  132252        00155696    From center line of nozzle (22") radially and    INSIDE condenser #32                  Y  Y  N  Y                        Shell        OPERATING EXPERIENCE f-20053 FWH-32B HTX                                  axially.
16 of 18                                                                                      3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                    R BE                  PO          W                    D                          IP                                                          SC  AF                            G              SI                          KS R                    IN        R OR EQ K                O                              TI O                                AT                  IN SU FO LD                  IN                  ZE                  R M                            T                            R                                  N                                  IO                    LA                  AW                                            EM N                                        UES            K                                                                          N PA IN  TI ON                                PI U                EX                      T      W                              DES T                  DR                    PE                        AR AM                            O                                                                        LO                    PIPE  PR R                                C                                        C                            EP EXTRACTION STEAM Drain 3R13EXAM. RE-INSPECT SEE DATA SHEET                                                                      9321-f-21513                      CALCULATION RE-INSPECTION-SNM 126                                    183861        00217955                                                                                            Y  Y  N  N                          6" FAC-05-EST-03                                    05UT005. extraction steam          TB elev 21ft 3" between Col 13 &14                                  /9321-F-20313                      program Aux Feed water 127              3FAC-07-AFW-01        184170        218266      PIPE& 45 DEG ELBOW. REFERENCE                                                          Y  Y  N  N    9321-F-20193.        2"          CALCULATION RE-INSPECTION-FAC DATASHEET IP3-UT-07-096                      Downstream of BFD-FCV-1121                                                                    MANAGER -
CALCULATION RE-INSPECTION-FAC 128              3FAC-07-AFW-02        184172        218291                                                                                              Y  Y  N  N    9321-F-20193.        2" Pipe. REFERENCE DATA SHEET IP3-UT-07-0Downstream of BFD-FCV-1123                                                                            MANAGER -
PIPE& 45 DEG ELBOW; PIPE & 90 DEG 129              3FAC-07-AFW-03        184173        218267      ELBOW. REFERENCE DATA SHEET IP3-UT- Downstream of throttle valves BFD-53              Y  Y  N  N    9321-F-20193.        2"/ 3"        CALCULATION RE-INSPECTION-FAC 07-098/099                            and BFD-55                                                                                            MANAGER -
130              3FAC-07-AFW-04        184174        218268      PIPE & 90 DEG ELBOW. REFERENCE DATA                                                    Y  Y  N  N    9321-F-20193.        2"          CALCULATION RE-INSPECTION-FAC SHEET IP3-UT-07-100                Upstream of BFD-FCV-1121                                                                                MANAGER -
131              3FAC-07-AFW-05        184176        218269      PIPE& 45 DEG ELBOW & 90 DEG ELBOW.                                                    Y  Y  N  N    9321-F-20193.        2"          CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET IP3-UT-07-102          Upstream of BFD-FCV-1123                                                                      MANAGER -
PIPE & 90 DEG ELBOW & TEE.
132              3FAC-07-AFW-06        184179        218292      REFERENCE DATA SHEET IP3-UT                                                        Y  Y  N  N    9321-F-20193.        2"/4"        CALCULATION RE-INSPECTION-FAC 103/104                                      Discharge from 31 ABFP                                                                        MANAGER -
133              3FAC-07-AFW-07        184182        218294      PIPE & 90 DEG ELBOW & TEE.                                                            Y  Y  N  N    9321-F-20193.        2"/4"        CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET IP3-UT-07-105          Discharge from 33 ABFP                                                                        MANAGER -
PIPE, ELBOW, EXPANDER TEE.
134              3FAC-07-AFW-08        184183        218295      REFERENCE DATA SHEET IP3-UT                                                        Y  Y  N  N    9321-F-20193.      2"/4"/6'      CALCULATION RE-INSPECTION-FAC 107/108/109                                  Discharge from 32 ABFP                                                                        MANAGER -
MISC Inspect piping off EST-17at intersection where 135                  97-PT-29          192068        227301      2",3" and 6" piping meet. Reference data sheet EXT steam drains off 33B FWH            Y  Y  N  N    9321-F-20313        2",3",6"      CALCULATION RE-INSPECTION-FAC 97UT192                                                                                                                                    MANAGER -
re-inspect reducer immediately DNSM of 5HD- Piping segments located approximately 2' 136                03-PT-18-04        192069        228221                                                                                              Y  Y  N  N    9321-F-20223        10x14"        CALCULATION RE-INSPECTION-FAC LCV-1127D. Reference data sheet 03UT051 South and 7' West of B4/15.7 El. 13'.
MANAGER -
AND SHELL AREA. INSPECT 2 PIPE TB. ELEV 53'-1" AT MSR DRAIN TANK                                  EC-H-50038 & EC-137                MSD-01.8A-8N        191663        227303      DIAMETERS FROM THE CENTERLINE                                                          Y  Y  N  Y                          12"          OPERATING EXPERIENCE 32A                                                                    H-50078 AXIALLY AND RADIALLY OR AS DIRECTED 17 of 18                                                                                          3R16 Fac Scope (Ipe0086871).Xls
FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER                      R BE                PO          W                    D                          IP                                              SC  AF                          G            SI                          KS R                IN        R OR EQ K              O                                TI O                        AT              IN SU FO LD                IN                ZE                  R M                        T                          R                                    N                          IO                LA                  AW                                        EM N                                    UES            K                                                                  N PA IN  TI ON                            PI U                EX                    T    W                              DES T                DR                  PE                        AR AM                        O                                                                  LO                PIPE  PR R                                C                                  C                        EP ADDITIONS RE-INSPECTION (TRENDING); WET 138                                  210799        248902      Re-inspect Elbow in accordance with Data                                  Y  Y  N  N  EC-H-50001          28" STEAM REPLACEMENT CANCELLED EX-02.14-25E                                sheet 3R15- FAC-09-002.                    15 FT ELEV.
RE-INSPECTION (TRENDING); WET 139                                  210808        248901      Re-inspect TEE in accordance with Data                                    N  Y  N  N  EC-H-50015          6" STEAM REPLACEMENT CANCELLED RHD-02.13A-16T                                sheet 3R15- FAC-09-028.                    33FT ELEV 140              34 FWH VENT LINE                  220153      INSPECT (3") PIPING AND FITTING ON 34 TB elev 30 ft - 34 FWH COMMON VENT  Y  Y  N  Y  9321-F-20223.      3"          OPERATING EXPERIENCE FWH COMMON VENT LINE FROM THE        LINE OPERATING VENTS 4(IN THE VECINITY OF LEAK REPAIR FIX ON ELBOW 4-HD-3-1) .
INSPECT FITTINGS AND ~ 3FT OF PIPING.
218489    248902-07 EX-02.14-25E                                Contingency replacement RHD02.13A-16T      218490    248901-07 Contingency replacement 18 of 18                                                                              3R16 Fac Scope (Ipe0086871).Xls}}

Latest revision as of 06:09, 12 November 2019

Entergy Pre-Filed Evidentiary Hearing Exhibit ENT000062 - Flow Accelerated Corrosion Inspection Points for 3R16
ML12088A435
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 03/28/2012
From:
Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12088A422 List:
References
RAS 22102, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12088A435 (18)


Text

ENT000062 Submitted: March 28, 2012 FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP CONDENSATE Inspect nozzle 1 CD-02.1A-01N 183277 00217613 39ft elev at FWH #32A Y Y N Y EC-H-50061 14 CHECWORKS - Ranked high on the Service Life Report Inspect component D/S of Valve CD-02.1A- Inspect CHECWORKS Components CD-05V. Inspect back to back elbows , plus u/p 02.1A-5V (Ranked high on the Service 42FT ELEV D/S OF 32 OF 32A FWH.

2 CD-02.1A-06E 183280 00217616 and d/s extensions. Elbows plus 3 inches on Y Y N Y EC-H-50061 14" Life Report). Components D/S of valve and valve CD-18 either sides of elbow welds. Inspect 6E/7E selected since valves are rarely UT TOGETHER INSPECTED DUE TO CONTOUR.

Inspect CHECWORKS Components CD-Inspect component D/S of Valve CD-02.1A-02.1A-5V (Ranked high on the Service 05V. Inspect back to back elbows , plus u/p 42FT ELEV D/S OF 32 OF 32A FWH. Life Report). Components D/S of valve 3 CD-02.1A-07E 183280 00217616 and d/s extensions. Elbows plus 3 inches on Y Y N Y EC-H-50061 14" and valve CD-18 selected since valves are rarely UT either sides of elbow welds. Inspect 6E/7E INSPECTED DUE TO CONTOUR and in TOGETHER vecinity.

Inspect components 01n/03e together. Inspect 4 CD-02.1B-01N 183282 00217617 nozzle and elbow plus 3 inches d/s of the 39ft elev at FWH #32B Y Y N Y EC-H-50061 14" CHECWORKS - Ranked high on the elbow weld. Service Life Report Inspect components 01n/03e together. Inspect 5 CD-02.1B-03E 183282 00217617 nozzle and elbow plus 3 inches d/s of the 39ft elev at FWH #32B Y Y N Y EC-H-50061 14" elbow weld. FEW INSPECTION IN SEGMENT Components CD-02.1B-7V (Ranked high component d/s of valve CD-02.1B-07V. on the Service Life Report). Components Inspect pipe & elbow. Inspect two pipe 42FT ELEV D/S OF 32B FWH. and D/S of valve selected since valves are 6 CD-02.1B-08P 183283 00217618 Y Y N Y EC-H-50061 14" diameters =28 inches plus elbows & 3 inches valve CD-8 rarely UT INSPECTED DUE TO D/S of elbow weld. Inspect 8P/9E TOGETHER CONTOUR and it is in close proximity to the valve.

Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 7 CD-02.1C-01N 183285 217592 Y Y N Y EC-H-50061 14" nozzle plus 2 pipe dia =28 inches of pipe valve CD-8 CHECWORKS - Ranked high on the elbow plus 3 inches d/s of the elbow weld.

Service Life Report Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 8 CD-02.1C-02P 183285 217592 Y Y N Y EC-H-50061 14" nozzle plus 2 pipe dia =28 inches of pipe valve CD-8 elbow plus 3 inches d/s of the elbow weld.

FEW INSPECTION IN SEGMENT Inspect components CD-02.1C-01N/02P/03E together. Inspect nozzle pipE & elbow. Inspect 42FT ELEV D/S OF 32C FWH. and u/s of 9 CD-02.1C-03E 183285 217592 Y Y N Y EC-H-50061 14" nozzle plus 2 pipe dia =28 inches of pipe valve CD-8 elbow plus 3 inches d/s of the elbow weld. FEW INSPECTION IN SEGMENT 10 CD-05.1A-1N 183295 00217593 Inspect nozzle 42 ft. Elev. At 35A FWH Y Y N Y EC-H-50064 14" CHECWORKS - Ranked high on the Service Life Report 1 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect CHECWORKS Components CD-Inspect components d/s of valve CD-05.1A- 05.1A-5V (Ranked high on the Service CD-05.1A-06P 05V. Inspect pipe & elbow. Inspect two pipe 32 FT. ELEV. OFF 35A FWH; D/S OF Life Report). Components D/S of valve 11 183297 00217594 Y Y N Y EC-H-50064 14" (CD-05.1A-05V) diameters =28 inches plus elbows & 3 inches VALVE CD-18-1 selected since valves are rarely UT D/S of elbow weld. Inspect 6P/7E TOGETHER INSPECTED DUE TO CONTOUR and is in vecinity.

Inspect components d/s of valve CD-05.1A-05V. Inspect pipe & elbow. Inspect two pipe 32 FT. ELEV. OFF 35A FWH; D/S OF 12 CD-05.1A-07E 183297 00217594 Y Y N Y EC-H-50064 14" diameters =28 inches plus elbows & 3 inches VALVE CD-18-1 D/S of elbow weld. Inspect 6P/7E TOGETHER FEW INSPECTION IN SEGMENT Inspect CHECWORKS Components CD-Inspect components d/s of valve CD-05.1B-05.1B-5V (Ranked high on the Service 05V. Inspect pipe, elbow & pipe. Inspect two 32 FT ELEV. OFF 35B FWH D/S OF Life Report). Components D/S of valve 13 CD-05.1B-06P 183304 00217596 pipe diameters =28 inches plus elbows & 3 Y Y N Y EC-H-50064 14" VALVE CD-18-2 selected since valves are rarely UT inches D/S of elbow welds. Inspect 6P/7E/8P INSPECTED DUE TO CONTOUR and is TOGETHER in vecinity.

Inspect components d/s of valve CD-05.1B-05V. Inspect pipe & elbow. Inspect two pipe 32 FT ELEV. OFF 35B FWH D/S OF 14 CD-05.1B-07E 183304 00217596 diameters =28 inches plus elbows & 3 inches Y Y N Y EC-H-50064 14" VALVE CD-18-2 D/S of elbow weld. Inspect 6P/7E/8P CALCULATION RE-INSPECTION-FAC TOGETHER MANAGER -

Inspect components d/s of valve CD-05.1B-05V. Inspect pipe & elbow. Inspect two pipe 32 FT ELEV. OFF 35B FWH D/S OF 15 CD-05.1B-08P 183304 00217596 diameters =28 inches plus elbows & 3 inches Y Y N Y EC-H-50064 14" VALVE CD-18-2 D/S of elbow weld. Inspect 6P/7E/8P CALCULATION RE-INSPECTION-FAC TOGETHER MANAGER -

Inspect reducing elbow (24x20) and pipe.

Inspect pipe and elbow plus upstream and 16 CD-02.4-4E 183307 00217597 downstream extension. Inspect 48" of pipe and ELEV. 24FT.6 ins. D/S OF TCV-1110 Y Y N Y EC-H-50061 24X20 Elbow plus 6 inches on either side of elbow CALCULATION RE-INSPECTION-FAC welds.Inspect 4E/1P TOGETHER MANAGER -

Inspect reducing elbow (24x20) and pipe.

Inspect pipe and elbow plus upstream and 17 CD-02.5-01P 183307 00217597 downstream extension. Inspect 48" of pipe and ELEV. 24FT.6 ins. D/S OF TCV-1110 Y Y N Y EC-H-50064 24 Elbow plus 6 inches on either side of elbow CHECWORKS - Ranked high on the welds.Inspect 4E/1P TOGETHER Service Life Report Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH 18 CD-02.3-15T 183309 00217599 ELEV. 24FT.6 ins. U/S OF TCV-1110 Y Y N Y EC-H-50061 24x18 PLUS 12 INCHES ON ALL SIDES OF TEE CHECWORKS - Ranked high on the welds. Service Life Report 19 CD-02.8A-08N 183310 00217600 Inspect piping ELEV.39FT OFF FWH 33A Y Y N Y EC-H-50061 14" CHECWORKS - Ranked high on the Service Life Report 2 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect piping D/S of valve CD-16. Inspect ELBOW,PIPE,ELBOW & ELEV 34 FT. 8 INS. UPSTREAM OF 20 CD-02.8B-08N 183317 00217602 Y Y N Y EC-H-50061 14" NOZZLE.(Components CD-02.8B-05E /06P FWH 33B & D/S OF VALVE CD-16 CHECWORKS - Ranked high on the

/07E/ 08N) Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW & ELEV 34 FT. 8 INS. UPSTREAM OF 21 CD-02.8B-05E 183317 00217602 Y Y N Y EC-H-50061 14" NOZZLE.(Components CD-02.8B-05E /06P FWH 33B & D/S OF VALVE CD-16 CHECWORKS - Ranked high on the

/07E/ 08N)

Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW & ELEV 34 FT. 8 INS. UPSTREAM OF 22 CD-02.8B-06P 183317 00217602 Y Y N Y EC-H-50061 14" NOZZLE.(Components CD-02.8B-05E /06P FWH 33B & D/S OF VALVE CD-16 CHECWORKS - Ranked high on the

/07E/ 08N) Service Life Report Inspect piping D/S of valve cd-16. Inspect ELBOW,PIPE,ELBOW & ELEV 34 FT. 8 INS. UPSTREAM OF 23 CD-02.8B-07E 183317 00217602 Y Y N Y EC-H-50061 14" NOZZLE.(Components CD-02.8B-05E /06P FWH 33B & D/S OF VALVE CD-16 CHECWORKS - Ranked high on the

/07E/ 08N) Service Life Report Inspect elbow plus upstream & downstream ELEV 34 FT. 8 INS. UPSTREAM OF 24 CD-02.8B-02E 183318 00217603 extension. Elbow plus 3 inches on either side Y Y N N EC-H-50061 14" FWH 33B & U/S OF VALVE CD-16 CALCULATION RE-INSPECTION-FAC of the elbow welds.

MANAGER -Last Inspected 2007 Inspect Pipe, elbow & Pipe. Inspect 28 inches ELEV 34 FT. 8 INS. UPSTREAM OF 25 CD-02.8C-02E 183319 00217333 of pipe. Inspect components CD-02.8C- Y Y N N EC-H-50061 14" FWH 33C & U/S OF VALVE CD-16 01P/02.8C-02E/ 02.8C-3E TOGETHER. CALCULATION RE-INSPECTION-FAC MANAGER - Last Inspected 2007 Inspect elbow & Pipe. Inspect 28 inches of pipe plus elbow and 3 inches on the upstream ELEV 34 FT. 8 INS. UPSTREAM OF 26 CD-02.8C-03P 183319 00217333 Y Y N N EC-H-50061 14" extension of the elbow. Inspect components FWH 33C & U/S OF VALVE CD-16 RE-INSPECTION (TRENDING) last 02.8C-02E/ 02.8C-3E TOGETHER.

inspected 2007 with 02.8C-2E Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH ELEV. 24FT 6 INS. OFF 35A FWH TO 27 CD-06.1-01T 183320 00217604 Y Y N N EC-H-50064 30X16 PLUS 12 INCHES ON ALL SIDES OF TEE BFP #32 CALCULATION RE-INSPECTION-FAC welds. MANAGER - Last Inspected 1997 Inspect elbow plus upstream & downstream ELEV 32 FT. 0 INS. UPSTREAM OF 28 CD-06.2A-02E 183321 00217605 extension. Elbow plus 12 inches on either side Y Y N N EC-H-50064 24" CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 of the elbow welds. MANAGER - last inspection 1992 ELEV 32 FT. 0 INS. DOWNSTREAM OF 29 CD-06.2A-08P 183322 00217607 Inspect piping 2 diameters = 48 inches. Y Y N N EC-H-50064 24" CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 MANAGER -

3 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect elbow plus upstream & downstream ELEV 24 FT. 6 INS. DOWNSTREAM OF 30 CD-06.2A-011E 183324 217606 extension. Elbow plus 12 inches on either side Y Y N N EC-H-50064 24" CALCULATION RE-INSPECTION-FAC VALVE CD-21-2 of the elbow welds. MANAGER -

31 CD-02.12-05P 183331 00217620 Inspect piping 2 diameters = 36 inches. D/S OF VALVE CD-15 (CD-02.12-04V) Y Y N N EC-H-50088 18" CALCULATION RE-INSPECTION-FAC MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH ELEV 32 FT. 0 INS. UPSTREAM OF 32 CD-02.6-3T 183332 00217612 Y Y N N EC-H-50061 24x14 PLUS 12 INCHES ON ALL SIDES OF TEE FWH 33B & U/S OF VALVE CD-16 CALCULATION RE-INSPECTION-FAC welds. MANAGER -

Inspect back to back elbows. Inspect elbows Plus U/S and D/S extensions ~ 3 inches on 33 CD-04.1C-02E 183333 00217621 ELEV 41 FT. 0 INS. OFF FWH 34C. Y Y N N EC-H-50062 14" either side of elbows.(CD-04.1C-02E &3E) CALCULATION RE-INSPECTION-FAC TOGETHER MANAGER -

Inspect back to back elbows. Inspect elbows Plus U/S and D/S extensions ~ 3 inches on 34 CD-04.1C-03E 183333 00217621 ELEV 41 FT. 0 INS. OFF FWH 34C. Y Y N N EC-H-50062 14" either side of elbows.(CD-04.1C-02E &3E) CALCULATION RE-INSPECTION-FAC TOGETHER MANAGER -

EXTRACTION ELEV. 39FT. 6 INS U/S OF VALVE 6EX- Inspected in 1997. Re-inspection or NSI =

35 EX-01.2-10L 183365 00217622 INSPECT LATERAL Y Y N N EC-H-50000 18"X12" 3R16. CALCULATION RE-INSPECTION-1 & 6 EX-4 FAC MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH ELEV. 31FT. 9 INS U/S OF LINE TO 36 EX-01.4-02T 183367 00217624 Y Y N N EC-H-50000 18X12 PLUS 3 INCHES ON ALL SIDES OF TEE FWH 36B &VALVE 6EX-5. CALCULATION RE-INSPECTION-FAC welds. MANAGER -

37 EX-02.2-01N 183368 00217625 Inspect nozzle TB. ELEV.44FT. 5 INS N EC-H-50071 10" CALCULATION RE-INSPECTION-FAC MANAGER -

Elbow and UPSM and DNSM extensions.

Turb. Bldg. Elev. 24'-6" U/S of hanger 38 EX-02.14-25E 183370 00217627 Prep. Elbow plus 12 inches U/S & D/S of Y Y Y N EC-H-50001 28" CALCULATION RE-INSPECTION-FAC 5EX-6 elbow welds. MANAGER -

Inspect Elbow, Pipe, Inspect COMPONENTS Inspect CHECWORKS Components EX-D/S OF VALVE 5EX-5 COMPONENTS EX- 02.17-2V (Ranked high on the Service EX-02.17-02V 39 183371 00217628 02.17-03E/04P. FOR PIPE 2 DIA=36 INCHES. Turb. Bldg. Elev. 42'-3" off FWH 35B Y Y Y Y EC-H-50001 18" Life Report). Components D/S of valve D/S = EX-02.17-03E Also inspect u/s extension of first elbow 8 selected since valves are rarely UT inches(d/s of valve) INSPECTED DUE TO CONTOUR.

4 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect Elbow, Pipe, . Inspect COMPONENTS D/S OF VALVE 5EX-5 COMPONENTS EX-Component also selected because of 40 EX-02.17-04P 183372 00217628 02.17-03E/04P. FOR PIPE 2 DIA=36 INCHES. Turb. Bldg. Elev. 42'-3" off FWH 35B Y Y Y Y EC-H-50001 18" proximity to highly ranked component.

Also inspect u/s extension of first elbow 8 inches(d/s of valve)

Elbow and UPSM and DNSM extensions.

41 EX-03.1B-33E 183377 00217631 Prep. Elbow plus 10 inches U/S & D/S of Turb. Bldg. Elev. 42'-2" off FWH 34B Y Y N N EC-H-50006 20" CALCULATION RE-INSPECTION-FAC elbow welds. MANAGER -

Elbow and UPSM and DNSM extensions.

42 EX-03.1C-37E 183379 00217634 Prep. Elbow plus 10 inches U/S & D/S of Turb. Bldg. Elev. 42'-2" off FWH 34C Y Y N N EC-H-50002 20" CALCULATION RE-INSPECTION-FAC elbow welds. MANAGER -

Inspect reducer plus U/S & D/S EXTENSION 6 Turb. Bldg. Elev. 24'-6" U/S of hanger 43 183380 00217635 Y Y N N EC-H-50008 28X20 CALCULATION RE-INSPECTION-FAC

" ON EITHER SIDE OF WELD. 3EX-23. LINE OFF 33B FWH EX-04.13-01R MANAGER -

Inspect PIPE &ELBOW. (EX-04..6-04P/05E) 44 183382 00217639 Turb. Bldg. Elev. 42'-2" off FWH 33A Y Y N N EC-H-50007 20" CALCULATION RE-INSPECTION-FAC For piping INSPECT 2 diameters = 40 inches.

EX-04..6-04P MANAGER -

Inspect PIPE & ELBOW. (EX-04..6-04P/05E) 45 183382 00217639 For piping INSPECT 2 diameters = 40 inches. Turb. Bldg. Elev. 42'-2" off FWH 33A Y Y N N EC-H-50007 20" Also inspect downstream extension of elbow. CALCULATION RE-INSPECTION-FAC EX-04..6-05E MANAGER -

Turb. Bldg. between Elev. 24'-2" & 42'-2".

46 183383 00217640 Inspect piping 2 diameters = 40 inches. Y Y N N EC-H-50007 20" CALCULATION RE-INSPECTION-FAC Line OFF 33A FWH EX-04.7-01P MANAGER -

FEEDWATER Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH TB. ELEV. 24'-5" D/S OF BFP 31 47 FW-01.2A-03T 183385 00217641 PLUS 10 INCHES ON ALL SIDES OF TEE Y Y N N EC-H-50039 20"X 6" DISCHARGE.

MAIN welds PLUD 2 INCHES D/S OF CALCULATION RE-INSPECTION-FAC BRANCH..

MANAGER -

Elbow and UPSM and DNSM extensions. TB. ELEV. 24'-5" D/S OF BFP 31 48 FW-01.2A-10E 183386 00217662 Prep. Elbow plus 10 inches U/S & D/S of DISCHARGE & FURTHER D/S OF Y Y N N EC-H-50039 20" CALCULATION RE-INSPECTION-FAC elbow welds. VALVE BFD2-3. MANAGER -

TB. ELEV. 24'-5" D/S OF BFP 31 49 FW-01.2A-23P 183387 00217663 Inspect piping 2 diameters = 40 inches. DISCHARGE & FURTHER D/S OF Y Y N N EC-H-50039 20" CALCULATION RE-INSPECTION-FAC HANGER BFD-11 MANAGER -

TB. ELEV. 24'-5" D/S OF BFP Inspect reducer plus U/S & D/S EXTENSION 6 50 FW-01.2B-27R 183388 00217664 32DISCHARGE & FURTHER D/S OF Y Y N N EC-H-50039 30X20 CALCULATION RE-INSPECTION-FAC

" ON EITHER SIDE OF WELD.

HANGER BFD-6. MANAGER -

5 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Elbow and UPSM and DNSM extensions.

Turb. Bldg. Elev. 23'-6" D/S of hanger 51 FW-01.3-15E 183389 00217665 Prep. Elbow plus 12 inches U/S & D/S of Y Y N N EC-H-50039 30" CALCULATION RE-INSPECTION-FAC BFD-16. LINE OFF FWH 36A elbow welds. MANAGER -

Turb. Bldg. Elev. 34'-9" D/S OF VALVE 52 FW-02.1C-10P 183394 00217672 Inspect piping 2 diameters = 36 inches. Y Y N N EC-H-50042 18" CALCULATION RE-INSPECTION-FAC BFD-4 =. LINE OFF FWH 36C MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH Turb. Bldg. Elev. 34'-9" D/S OF VALVE 53 FW-02.1C-11T 183395 00217673 Y Y N N EC-H-50042 30X18 PLUS 12 INCHES ON ALL SIDES OF TEE BFD-4 =. LINE OFF FWH 36C CALCULATION RE-INSPECTION-FAC welds. MANAGER -

Elbow and UPSM and DNSM extensions. Turb. Bldg. Elev. 29'-9" D/S OF 54 FW-02.4-05E 183396 00217700 Prep. Elbow plus 12 inches U/S & D/S of HANGER BFD-22 =. LINE OFF FWH Y Y N N EC-H-50039 30" CALCULATION RE-INSPECTION-FAC elbow welds. 36A MANAGER -

6 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect PIPE & ELBOW. (FW-02.4-07E/08P)

AUX. Bldg. Elev. 29'-9" D/S OF For piping INSPECT 2 diameters = 60 inches.

55 FW-02.4-07E 183397 00217699 HANGER BFD-22 =. LINE OFF FWH Y Y N Y EC-H-50040 30" PLUS U/S EXTENSION OF ELBOW =12 CHECWORKS - Ranked high on the 36A INCHES Service Life Report Inspect PIPE & ELBOW. (FW-02.4-07E/08P)

AUX. Bldg. Elev. 29'-9" D/S OF For piping INSPECT 2 diameters = 60 inches.

56 FW-02.4-08P 183397 00217699 HANGER BFD-22 =. LINE OFF FWH Y Y N Y EC-H-50040 30" PLUS U/S EXTENSION OF ELBOW =12 CHECWORKS - Ranked high on the 36A INCHES Service Life Report Inspect PIPE, ELBOW& PIPE. (FW-02.4-12P/13E/14P) For piping INSPECT 2 AUX. Bldg. Elev. 29'-9" D/S OF 57 FW-02.4-13E 183398 00217697 Y Y N Y EC-H-50040 30" diameters = 60 inches. PLUS U/S HANGER BFD-25. LINE OFF FWH 36A CHECWORKS - Ranked high on the EXTENSION OF ELBOW =12 INCHES Service Life Report Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH AUX. Bldg. Elev. 43'-0" D/S OF 58 FW-02.4-19T 183399 00217696 Y Y N N EC-H-50040 30X18 PLUS 12 INCHES ON ALL SIDES OF TEE HANGER BFD-32. LINE OFF FWH 36A CALCULATION RE-INSPECTION-FAC welds. MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH AUX. Bldg. Elev. 43'-0" U/S OF EC-H-50040/9321-59 FW-02.6-02T (Elbow) 183400 00217695 PLUS 12 INCHES ON ALL SIDES OF TEE Y Y N Y 30X6 HANGER BFD-33. LINE OFF FWH 36A F-20613 CHECWORKS - Ranked high on the welds. NOTE this really an elbow attached and not a tee. Service Life Report Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH AUX. Bldg. Elev. 43'-0" U/S OF EC-H-50040/9321-60 FW-02.7-02T (Elbow) 183401 00217694 PLUS 12 INCHES ON ALL SIDES OF TEE Y Y N Y 30X6 HANGER BFD-33. LINE OFF FWH 36A F-20613 welds. NOTE this really an elbow attached and CHECWORKS - Ranked high on the not a tee. Service Life Report Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH AUX. Bldg. Elev. 43'-0" D/S OF 61 FW-02.7-4T 183402 00217693 Y Y N N EC-H-50040 30X18 PLUS 12 INCHES ON ALL SIDES OF TEE HANGER BFD-33. LINE OFF FWH 36A CALCULATION RE-INSPECTION-FAC welds. MANAGER -

Reducer and UPSM and DNSM extensions.

AUX. BLDG. Elev 22'-3" adjacent to 62 FW-02.8A-26R 183405 00217690 Prep. reducer plus 8 inches of piping U/S & Y Y N N EC-H-50040 18" FCV-417 D/S CALCULATION RE-INSPECTION-FAC D/S of reducer welds.

MANAGER -

AUX. Bldg. BETWEEN ELEV. 43'-0"& 22 63 FW-02.8B-01P 183406 00217689 Inspect piping 2 diameters = 36 inches. Y Y N N EC-H-50040 18" CALCULATION RE-INSPECTION-FAC FT 3 INS U/S OF VALVE FCV-427 MANAGER -

Reducer and UPSM and DNSM extensions.

AUX. BLDG. Elev 22'-3" adjacent to 64 FW-02.8B-25R 183407 00217688 Prep. reducer plus 8 inches of piping U/S & Y Y N N EC-H-50040 18" BFD-MOV-5-2 CALCULATION RE-INSPECTION-FAC D/S of reducer welds.

MANAGER -

7 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP AUX. BLDG. Elev 57'-6" adjacent to BFD-65 FW-02.8C-20P 183409 00217685 Inspect piping 2 diameters = 36 inches. Y Y N Y EC-H-50041 18" CHECWORKS - Ranked high on the 7-4 Service Life Report Reducer and UPSM and DNSM extensions.

AUX. BLDG. Elev 22'-3" adjacent to 66 FW-02.8C-25R 183410 00217684 Prep. reducer plus 8 inches of piping U/S & Y Y N N EC-H-50040 18" CALCULATION RE-INSPECTION-FAC FCV-447 D/S D/S of reducer welds. MANAGER -

Inspect CHECWORKS Components FW-02.1B-5V (Ranked high on the Service Inspect components D/S ov valve FW-02.8d-Life Report). Components D/S of valve 05V. Elbow and PIPE. Prep. 2 DIA =36" for AUX. BLDG. Elev 22'-3" adjacent to 67 FW-02.8D-07E 183413 00217682 Y Y N Y EC-H-50040 18" selected since valves are rarely UT pipe and Elbow plus 8 inches D/S of elbow FCV-437 D/S INSPECTED DUE TO CONTOUR. Other weld. FW-02.8D-07E/8P component selected in close proximity to highly ranked component.

Elbow and PIPE. Prep. 2 DIA =36" for pipe AUX. BLDG. Elev 22'-3" adjacent to CHECWORKS - Ranked high on the 68 FW-02.8D-08P 183413 00217682 and Elbow plus 8 inches D/S of elbow weld. Y Y N Y EC-H-50040 18" FCV-437 D/S Service Life Report AND IN VECINITY OF FW-02.8D-07E/8P OTHER SELECTED COMPONENTS.

8 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP AUX. BLDG. Elev 57'-6" adjacent to BFD-69 FW-02.8D-19P 183414 00217680 Inspect piping 2 diameters = 36 inches. Y Y N Y EC-H-50041 18" CHECWORKS - Ranked high on the 7-3 Service Life Report AUX. BLDG. Elev 22'-3" adjacent to 70 FW-02.8D-24R 183415 00217681 INSPECT REDUCER Y Y N Y EC-H-50040 18"X12" CALCULATION RE-INSPECTION-FAC FCV-437 D/S MANAGER -

Elbow and UPSM and DNSM extensions. VC ELEV. 104'-10". Line to 34 Steam 71 FW-03.1C-14E 183418 00217678 Prep. Elbow plus 8 inches U/S & D/S of elbow generator Y Y N N EC-H-50046 18" CALCULATION RE-INSPECTION-FAC welds. MANAGER -

TB ELEV. 24'-5"D/S OF 31BFP Inspect Elbow & Pipe. Inspect 2 dia = 12" of DISCHARGE @ COMPONENT FW-72 FW-04.1A-01E 183421 00217677 Y Y N N EC-H-50084 6" CALCULATION RE-INSPECTION-FAC pipe plus elbow 01.2A-3T MANAGER -

HEATER DRAINS Inspect reducer plus U/S & D/S EXTENSION 6 73 HD-09.1A-02R 183427 00217412 TB ELEV 38'- 3" D/S OF LCV 1121 Y Y N N EC-H-50031 12"X10"

" ON EITHER SIDE OF WELD IF POSSIBLE.. CALCULATION RE-INSPECTION-FAC MANAGER -

Inspect CHECWORKS Components HD-11.1A-02V (Ranked high on the Service HD-11.1A-02V Inspect reducer plus U/S & D/S EXTENSION 6 TB. ELEV 15 FT D/S OF HTR DRAIN 74 183428 00217413 Y Y N Y EC-H-50079 12"x8" Life Report). Components D/S of valve (HD-11.2A-01R) " ON EITHER SIDE OF WELD IF POSSIBLE.. PUMP 31 AND VALVE HD-1 selected since valves are rarely UT INSPECTED DUE TO CONTOUR.

Inspect CHECWORKS Components HD-11.1B-02V (Ranked high on the Service Inspect reducer plus U/S & D/S EXTENSION 6 TB. ELEV 15 FT D/S OF HTR DRAIN 75 HD-11.2B-01R 183429 00217408 Y Y N Y EC-H-50079 12"x8" Life Report). Components D/S of valve

" ON EITHER SIDE OF WELD IF POSSIBLE.. PUMP 32 AND VALVE HD-1 selected since valves are rarely UT INSPECTED DUE TO CONTOUR.

Inspect CHECWORKS Components HD-12.1A-01V (Ranked high on the Service Inspect component d/s of valve HD-2 TB. ELEV 15 FT D/S OF HTR DRAIN 76 183431 00217406 EC-H-50079 12" Life Report). Components D/S of valve component HD-12.2A-03E. PUMP 31 AND VALVE HD-1 selected since valves are rarely UT HD-12.2A-03E INSPECTED DUE TO CONTOUR.

TB. ELEV 15 FT D/S OF HTR DRAIN 77 183433 00217403 Inspect 2 dia = 24 inches d/s of orifice Y Y N Y EC-H-50079 12" PUMP 32 AND VALVE HD-1 CALCULATION RE-INSPECTION-FAC HD-12.2B-06O MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH TB. ELEV 15 FT D/S OF HTR DRAIN 78 183434 00217404 Y Y N Y EC-H-50079 12" PLUS 6 INCHES ON ALL SIDES OF TEE PUMP 32 AND VALVE HD-1 CALCULATION RE-INSPECTION-FAC HD-12.2B-08T welds. MANAGER -

9 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP TB. ELEV 32' 0" D/S OF HTR DRAIN 79 HD-12.3-01P 183435 00217396 Inspect piping 2 diameters = 32 inches. Y Y N N EC-H-50079 16" PUMP 32. CALCULATION RE-INSPECTION-FAC MANAGER -

Rre-inspect per data sheet 99UT261. Inspect 3 80 99-PT-29 183436 00217402 VENT CHAMBER DRAIN Y Y N N 9321-F-29013 3" elbows & 3 pipes. CALCULATION RE-INSPECTION-Small Bore/ Augmented Program HEATER DRAIN TANK LARGE DUMP TO 33 Inspect puiping and fitting d/s of 5HD-81 183437 00217394 Y Y N Y EC-F-20223 SH-2 14" CONDENSER LCV-1127B LEAKS AFFECTING THERMAL 5HD-LCV-1127B EFFICIENCY HEATER DRAIN TANK LARGE DUMP TO 32 Inspect puiping and fitting d/s of 5HD-82 183438 00217395 Y Y N Y EC-F-20223 SH-2 14" CONDENSER LCV-1127C LEAKS AFFECTING THERMAL 5HD-LCV-1127C EFFICIENCY 10 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP RE-HEATER DRAINS tb-elev. 46'-0" d/s of FE-1257-3 Re-Inspect piping D/S OF FE1257-3 (includes straight pipe expander and elbow RHD01.10A-83 RHD01.10A-18F 183739 217723 EC-H-50014 6" 18F/20R&RHD01.11A-01E). last inspected 2005 reference datasheet 05UT077. CALCULATION RE-INSPECTION-FAC Y Y N N MANAGER -

TB. ELEV 56'-4" OFF REHEATER Inspect nozzle, pipe & elbow (RHD01.10A-DRAIN TANK 33A 84 RHD01.10A-04N 183740 00217711 04N/5P/6E. For pipe 2dia = 12 inches. Also EC-H-50014 6" CHECWORKS - Ranked high on the inspect d/s extension of elbow =2 insches Y Y N Y Service Life Report TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.10A-DRAIN TANK 33A Component also selected because of 85 RHD01.10A-05P 183740 00217711 04N/5P/6E. For pipe 2dia = 12 inches. Also EC-H-50014 6" proximity to highly ranked component.

inspect d/s extension of elbow =2 insches Y Y N Y TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.10A-DRAIN TANK 33A Component also selected because of 86 RHD01.10A-06E 183740 00217711 04N/5P/6E. For pipe 2dia = 12 inches. Also EC-H-50014 6" proximity to highly ranked component.

inspect d/s extension of elbow =2 insches Y Y N Y TB. ELEV. 47'-7" D/S OF FLOW Re-Inspect piping D/S OF flow element. last 87 RHD01.10B-26F 183741 217712 ELEMENT FE-1258-3. LINE OFF RHD EC-H-50016 6" inspected 2005 reference datasheet 05UT074. CALCULATION RE-INSPECTION-FAC TANK 33B Y Y N N MANAGER -

RE-INPECT REDUCER . LAST INSPECTED TB. ELEV. 38'-9" U/S OF VALVE LCV-88 RHD01.13A-01R 183745 00217713 EC-H-50014 6" CALCULATION RE-INSPECTION-FAC 1999 REFERENCE DATA SHEET 99UT255 1104B Y Y N N MANAGER -

TB. ELEV. 44'-8" D/S OF FLOW INPECT 24" of piping U/S and D/S of flow 89 RHD01.1A-35F 183748 00217714 ELEMENT FE-1257-1. LINE OFF RHD Y Y N N EC-H-50011 6" CALCULATION RE-INSPECTION-FAC element TANK 31A MANAGER -

TB. ELEV 56'-4" OFF REHEATER Inspect nozzle , pipe & elbow (RHD01.3A- DRAIN TANK 32A 90 RHD01.3A-04N 183749 00217715 04N/5P/6E. For pipe 2dia = 12 inches. Also Y Y N Y EC-H-50012 6" inspect d/s extension of elbow =2 insches CHECWORKS - Ranked high on the Service Life Report Inspect nozzle , pipe & elbow (RHD01.3A- TB. ELEV 56'-4" OFF REHEATER DRAIN TANK 32A Component also selected because of 91 RHD01.3A-05P 183749 00217715 04N/5P/6E. For pipe 2dia = 12 inches. Also Y Y N Y EC-H-50012 6" proximity to highly ranked component.

inspect d/s extension of elbow =2 insches TB. ELEV 56'-4" OFF REHEATER Inspect nozzlw , pipe & elbow (RHD01.3A-DRAIN TANK 32A Component also selected because of 92 RHD01.3A-06E 183749 00217715 04N/5P/6E. For pipe 2dia = 12 inches. Also Y Y N Y EC-H-50012 6" proximity to highly ranked component.

inspect d/s extension of elbow =2 insches 11 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP TB. ELEV 49'-1" OFF REHEATER REINPECT (6") ELBOW & D/S PIPING. DRAIN TANK 32B 93 RHD01.3B-06E 183752 00217716 Y Y N N EC-H-50009 6" CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET 99UT251.

MANAGER -

INPECT U/S & D/S OF FLOW ELEMENT FE- TB. ELEV. 47'-10" D/S OF FLOW 94 RHD01.5B-03F 183754 00217717 1257-2 ~ 2 DIA = 12" ON EITHER SIDE OF ELEMENT FE-1258-2. LINE OFF RHD Y Y N N EC-H-50009 6" CALCULATION RE-INSPECTION-FAC ELEMENT. TANK 32B MANAGER -

REINPECT EXPANDER PER DATA SHEET TB. ELEV. 47'-8" U/S OF VALVE LCV-95 RHD01.7B-03R 183758 00217719 Y Y N N EC-H-50009 10X6 CALCULATION RE-INSPECTION-99UT277. 1105A TRENDING DATABASE Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH PLUS 4 INCHES ON ALL SIDES OF TEE TB. ELEV. 31'-8" D/S OF VALVE RHD-2.

96 RHD02.10A-11T 183760 00217704 Y Y N N EC-H-50015 8X6 MAIN welds PLUS 2 INCHES D/S OF LINE OFF FWH 36B BRANCH.. REFERENCE DATASHEET 3R14- CALCULATION RE-INSPECTION-FAC FAC-07-062 MANAGER -

12 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH PLUS 2 INCHES ON ALL SIDES OF TEE TB. ELEV. 39'-3" U/S OF VALVE RHD-1.

97 RHD02.12B-11T 183763 00217705 Y Y N N EC-H-50010 MAIN welds PLUS 2 INCHES D/S OF LINE OFF FWH 36B BRANCH.REFERENCE DATA SHEETS 3R15- CALCULATION RE-INSPECTION-FAC FAC-09-158/159. 6X6 MANAGER -

Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH PLUS 2 INCHES ON ALL SIDES OF TEE TB. ELEV. 42'-9" D/S OF VALVE RHD-1.

98 RHD02.13A-16T 183765 00217706 Y Y N N EC-H-50015 6X6 MAIN welds PLUS 2 INCHES D/S OF LINE OFF FWH 36B BRANCH.REFERENCE DATA SHEET 3R15-CALCULATION RE-INSPECTION-FAC FAC-09-028.

MANAGER -

Inspect PUP PIPING U/S OF Nozzle.

TB. ELEV. 42'-9" D/S OF VALVE RHD-1.

99 RHD02.14A-01N 183769 00217707 REFREENCE DATA SHEET 3R14-FAC Y Y N N EC-H-50015 8" CALCULATION RE-INSPECTION-FAC LINE OFF FWH 36B 058. MANAGER -

INSPECT EXPANDER . REFERENCE DATA TB. ELEV. 38'-9" D/S OF VALVE LCV-100 RHD02.3A-02R 183787 00217709 Y Y N N EC-H-50015 4X6" CALCULATION RE-INSPECTION-FAC SHEET 3R14-FAC-07-054 1104A MANAGER -

INSPECT EXPANDER . REFERENCE DATA TB. ELEV. 38'-9" D/S OF VALVE LCV-101 RHD02.5A-02R 183790 00217710 Y Y N N EC-H-50015 4X6" CALCULATION RE-INSPECTION-FAC SHEET 3R14-FAC-07-016 1104B MANAGER -

MSR DRAINS TB. ELEV. 21'-6" AT HEATER DRAIN TANK 102 MSD-01.10A-25N 183806 00217929 Inspect nozzle Y Y N N EC-H-50035 6" CALCULATION RE-INSPECTION-FAC MANAGER -

TB. ELEV 43'-6" BELOW MSR DRAIN 103 MSD-01.10B-02E 183807 00217930 Inspect elbow. Reference data sheet 99UT283 TANK 32B Y Y N N EC-H-50038 6" CALCULATION RE-INSPECTION-FAC MANAGER -

TB. ELEV 39'-6" BELOW MSR DRAIN Elbow and UPSM and DNSM extensions.

TANK 32B & D/S OF VALVE 5-HD-2 104 MSD-01.10B-07E 183808 00217931 Prep. Elbow plus 2 inches U/S & D/S of elbow Y Y N N EC-H-50038 6" CALCULATION RE-INSPECTION-FAC welds. Reference data sheet 99UT284 MANAGER -

Inspect TEE, BRANCH and upstream & TB. ELEV 53'96" 33A MSR DRAIN U/S downstream extensions, TEE & BRANCH OF VALVE 5HD-1.

105 MSD-01.13A-01T 183809 217932 PLUS 6 INCHES ON ALL SIDES OF TEE Y Y N N EC-H-50078 12" MAIN welds PLUS 6 INCHES D/S OF CALCULATION RE-INSPECTION-FAC BRANCH.. MANAGER -

13 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP TB. ELEV 34'-0" BELOW MSR DRAIN Reinspect (6") piping .Inspected 1999. TANK 31B & D/S OF VALVE 5-HD-3 106 MSD-01.5B-11P-2 183813 00217934 Y Y N N EC-H-50038 6" CALCULATION RE-INSPECTION-FAC Reference datasheet 99UT280 ~24 "

MANAGER -

3R14 EXAM. RE-INSPECT SEE DATA Turbine Building. Located SHEET 3R14-FAC-07-104. Piping segments 107 FAC-07-VCD-05 183818 00217936 from MSR 32B. Two (2) 90 degree elbows per approximately 12' west and on the Y Y N N 9321-F-29013 3" CALCULATION RE-INSPECTION-FAC previous exam. centerline of F/19, El. 46' MANAGER -

3R14 EXAM. RE-INSPECT SEE DATA SHEET 3R14-FAC-07-055. EXAM CONSISTS Turbine Building. Located approximately 108 FAC-07-VCD-07 183819 00217937 Y Y N N 9321-F-20233 3" OF ELBOW DOWNSTREAM OF VCD-2. 7' West and 4' North and F/17. El 53' CALCULATION RE-INSPECTION-FAC MSR 33B MANAGER -

3R14 EXAM. RE-INSPECT SEE DATA TB EL 52'; VCD Discharge from MSR 109 FAC-07-VCD-09 183823 00217939 Y Y N N 9321-F-20233 3" SHEET 3R14-FAC-07-101 31A CALCULATION RE-INSPECTION-FAC MANAGER -

TB EL 36' West of 33' mezz stairs; VCD 3R14 EXAM. RE-INSPECT SEE DATA Discharge from MSR 32A; 2 elbows 110 FAC-07-VCD-11 183828 00217940 SHEET 3R14-FAC-07-039/046. VCD Y Y N N 9321-F-20233 3" CALCULATION RE-INSPECTION-FAC Discharge from MSR 32A; 2 elbows MANAGER -

14 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP 3R10 EXAM. RE-INSPECT SEE DATA TB EL 47'-8" VCD Discharge from MSR 111 99-PT-25-2 183833 00217941 Y Y N N 9321-29013 3" SHEET 99UT258. VDC 31A CALCULATION RE-INSPECTION-TRENDING DATABASE 3R10 EXAM. RE-INSPECT SEE DATA TB EL 46'-3" VCD Discharge from MSR 112 99-PT-29-5 183837 00217942 Y Y N N 9321-29013 3" SHEET 99UT261. VDC 31B CALCULATION RE-INSPECTION-TRENDING DATABASE TB. approximately 12' West and on the 3R12 EXAM. RE-INSPECT SEE DATA centerline of F/19, El. 46'.

113 03-PT-06-03 183838 00217944 Y Y N N 9321-29013 3" SHEET 03UT073. HEATER DRAIN CALCULATION RE-INSPECTION-TRENDING DATABASE TB. CONDENSER 31; 3' South and 3' 3R12 EXAM. RE-INSPECT SEE DATA West of D6/15.7. From El. 36', 3' under 114 03-PT-04-02/03 183839 00217945 Y Y N N 9321-F-20233 3" SHEET 03UT019. HEATER DRAIN grating CALCULATION RE-INSPECTION-TRENDING DATABASE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 31 B MSR NOZZLE AND SHELL 31B 115 MSD-01.3B-08N 183844 00217943 Y Y N Y EC-H-50038 12" (MSD-01.3B-08N) .

OPERATING EXPERIENCE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 32 B MSR NOZZLE AND SHELL 32B 116 MSD-01.8B-08N 183845 00217946 Y Y N Y EC-H-50038 12" (MSD-01.8B-08N) .

OPERATING EXPERIENCE TB. ELEV 53'-1" AT MSR DRAIN TANK INSPECT 33 B MSR NOZZLE AND SHELL 33B 117 MSD-01.13B-10N 183847 00217947 Y Y N Y EC-H-50038 12" (MSD-01.13B-10N) .

OPERATING EXPERIENCE PRE-SEPARATOR DRAINS Inspect TEE, BRANCH and upstream &

downstream extensions, TEE & BRANCH 118 PD-02.3-01T 183848 00217948 PLUS 4 INCHES ON ALL SIDES OF TEE Y Y N N 16 MAIN welds PLUS 6 INCHES D/S OF Turb Bldg. Elevation 16'-6"; Turb-Gen CALCULATION RE-INSPECTION-FAC BRANCH.. end. EC-H-50077 MANAGER -

MAIN STEAM Main Steam Venturi from 33 SG. Inspect drain CONDITION REPORT-CR-IP3-2009-119 183849 217950 slot area. Reference datasheet 3R15-FAC VC El 107' Y Y N Y 9321-F-25423 28" 01453 MS-FE-439-DS 117 Inspect main steam trap piping 120 01-PT-24-12 183851 00217951 segment 12(01-PT-24-12). Reference Y Y N N 9321-F-20423 3/4 & 1" CALCULATION RE-INSPECTION-SNM data sheet 01UT037. UPSTREAM OF VALVE MS-119-3 program 15 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP Elbow and Piping DNSM of MS-FCV-1157 until it enters the condenser. 3R12EXAM. RE-121 03-PT-09-05/06/08 183852 00217952 Y Y N N 9321-F-20173 1.5"/2" INSPECT SEE DATA SHEET 03UT093. TB . ELEV 31'-0" MEZZANNINE UNDER CALCULATION RE-INSPECTION-SNM extraction steam HP-TURBINE program 122 MS-FCV-1154 183854 00217953 32MSLine HP Turb. Drain to Cond. TB . ELEV 31'-0" MEZZANNINE UNDER Y Y N Y 9321-F-20173 1" PROBLEMS AFFECTING THERMAL HP-TURBINE EFFICIENCY piping/fittings downstream of LCV- 32B moisture separator drain tank to PROBLEMS AFFECTING THERMAL 123 LCV-1109 183857 00217954 Y Y N Y 9321-F-20233 6" 1109 DCT EFFICIENCY FEEDWATER HEATER SHELLS Inspect FWH 31A shell. Inspect 2 pipe dia.

EC-F-20203/ 9321-124 132247 00155694 From center line of inlet nozzle (26") radially Inside condenser #33 Y Y N Y Shell OPERATING EXPERIENCE f-20053 FWH-31A HTX and axially.

Inspect FWH 32B shell. Inspect 2 pipe dia.

EC-F-20203/ 9321-125 132252 00155696 From center line of nozzle (22") radially and INSIDE condenser #32 Y Y N Y Shell OPERATING EXPERIENCE f-20053 FWH-32B HTX axially.

16 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP EXTRACTION STEAM Drain 3R13EXAM. RE-INSPECT SEE DATA SHEET 9321-f-21513 CALCULATION RE-INSPECTION-SNM 126 183861 00217955 Y Y N N 6" FAC-05-EST-03 05UT005. extraction steam TB elev 21ft 3" between Col 13 &14 /9321-F-20313 program Aux Feed water 127 3FAC-07-AFW-01 184170 218266 PIPE& 45 DEG ELBOW. REFERENCE Y Y N N 9321-F-20193. 2" CALCULATION RE-INSPECTION-FAC DATASHEET IP3-UT-07-096 Downstream of BFD-FCV-1121 MANAGER -

CALCULATION RE-INSPECTION-FAC 128 3FAC-07-AFW-02 184172 218291 Y Y N N 9321-F-20193. 2" Pipe. REFERENCE DATA SHEET IP3-UT-07-0Downstream of BFD-FCV-1123 MANAGER -

PIPE& 45 DEG ELBOW; PIPE & 90 DEG 129 3FAC-07-AFW-03 184173 218267 ELBOW. REFERENCE DATA SHEET IP3-UT- Downstream of throttle valves BFD-53 Y Y N N 9321-F-20193. 2"/ 3" CALCULATION RE-INSPECTION-FAC 07-098/099 and BFD-55 MANAGER -

130 3FAC-07-AFW-04 184174 218268 PIPE & 90 DEG ELBOW. REFERENCE DATA Y Y N N 9321-F-20193. 2" CALCULATION RE-INSPECTION-FAC SHEET IP3-UT-07-100 Upstream of BFD-FCV-1121 MANAGER -

131 3FAC-07-AFW-05 184176 218269 PIPE& 45 DEG ELBOW & 90 DEG ELBOW. Y Y N N 9321-F-20193. 2" CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET IP3-UT-07-102 Upstream of BFD-FCV-1123 MANAGER -

PIPE & 90 DEG ELBOW & TEE.

132 3FAC-07-AFW-06 184179 218292 REFERENCE DATA SHEET IP3-UT Y Y N N 9321-F-20193. 2"/4" CALCULATION RE-INSPECTION-FAC 103/104 Discharge from 31 ABFP MANAGER -

133 3FAC-07-AFW-07 184182 218294 PIPE & 90 DEG ELBOW & TEE. Y Y N N 9321-F-20193. 2"/4" CALCULATION RE-INSPECTION-FAC REFERENCE DATA SHEET IP3-UT-07-105 Discharge from 33 ABFP MANAGER -

PIPE, ELBOW, EXPANDER TEE.

134 3FAC-07-AFW-08 184183 218295 REFERENCE DATA SHEET IP3-UT Y Y N N 9321-F-20193. 2"/4"/6' CALCULATION RE-INSPECTION-FAC 107/108/109 Discharge from 32 ABFP MANAGER -

MISC Inspect piping off EST-17at intersection where 135 97-PT-29 192068 227301 2",3" and 6" piping meet. Reference data sheet EXT steam drains off 33B FWH Y Y N N 9321-F-20313 2",3",6" CALCULATION RE-INSPECTION-FAC 97UT192 MANAGER -

re-inspect reducer immediately DNSM of 5HD- Piping segments located approximately 2' 136 03-PT-18-04 192069 228221 Y Y N N 9321-F-20223 10x14" CALCULATION RE-INSPECTION-FAC LCV-1127D. Reference data sheet 03UT051 South and 7' West of B4/15.7 El. 13'.

MANAGER -

AND SHELL AREA. INSPECT 2 PIPE TB. ELEV 53'-1" AT MSR DRAIN TANK EC-H-50038 & EC-137 MSD-01.8A-8N 191663 227303 DIAMETERS FROM THE CENTERLINE Y Y N Y 12" OPERATING EXPERIENCE 32A H-50078 AXIALLY AND RADIALLY OR AS DIRECTED 17 of 18 3R16 Fac Scope (Ipe0086871).Xls

FLOW ACCELERATED CORROSION INSPECTION POINTS FOR 3R16 ER R BE PO W D IP SC AF G SI KS R IN R OR EQ K O TI O AT IN SU FO LD IN ZE R M T R N IO LA AW EM N UES K N PA IN TI ON PI U EX T W DES T DR PE AR AM O LO PIPE PR R C C EP ADDITIONS RE-INSPECTION (TRENDING); WET 138 210799 248902 Re-inspect Elbow in accordance with Data Y Y N N EC-H-50001 28" STEAM REPLACEMENT CANCELLED EX-02.14-25E sheet 3R15- FAC-09-002. 15 FT ELEV.

RE-INSPECTION (TRENDING); WET 139 210808 248901 Re-inspect TEE in accordance with Data N Y N N EC-H-50015 6" STEAM REPLACEMENT CANCELLED RHD-02.13A-16T sheet 3R15- FAC-09-028. 33FT ELEV 140 34 FWH VENT LINE 220153 INSPECT (3") PIPING AND FITTING ON 34 TB elev 30 ft - 34 FWH COMMON VENT Y Y N Y 9321-F-20223. 3" OPERATING EXPERIENCE FWH COMMON VENT LINE FROM THE LINE OPERATING VENTS 4(IN THE VECINITY OF LEAK REPAIR FIX ON ELBOW 4-HD-3-1) .

INSPECT FITTINGS AND ~ 3FT OF PIPING.

218489 248902-07 EX-02.14-25E Contingency replacement RHD02.13A-16T 218490 248901-07 Contingency replacement 18 of 18 3R16 Fac Scope (Ipe0086871).Xls