ML12088A437

From kanterella
Jump to navigation Jump to search
Entergy Pre-Filed Evidentiary Hearing Exhibit ENT000060 - 2R16 FAC Master Inspection List (Mil)
ML12088A437
Person / Time
Site: Indian Point  
Issue date: 03/28/2012
From:
Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12088A422 List:
References
RAS 22102, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12088A437 (4)


Text

2R16 FAC MASTER INSPECTION LIST (MIL)

No.

Component Name Component Geometry Type Line Name OD (U/S Main/

Large End)

Tnom (U/S Main/

Large End)

Tnom (D/S Main/

Small End)

OD (Small or Branch)

Tnom (Tee Branch)

Design Pressure Material Allowable Tmin req (U/S Main/

Large End)

Tmin req (D/S Main/

Small End)

Tmin req (Tee Branch)

Comments Building/

Bldg Elev.

Component Elevation Bldg Col Bldg Row Insul (Y/N)

Ref Dwg WO#

(IP2- )

Pre-outage Priority Scaffold (Y/N) 1 3EXA-10 90-DEG ELBOW 01_3RD POINT ES TO FWH 23A 28.000 0.313 0.313 0.000 0.000 50 15000 0.128 0.128 n/a 2R16 WET STM REPLACEMENT-deferred TH - 36' 39'-6" 18 A Yes 9321-F-2068 03-26514 Y

X 2

3EXA-9 90-DEG ELBOW 01_3RD POINT ES TO FWH 23A Scope Add 3

3EXB-2 90-DEG ELBOW 02_3RD POINT ES TO FWH 23B 20.000 0.250 0.250 0.000 0.000 50 15000 0.100 0.100 n/a 2R16 WET STM REPLACEMENT TH - 36' 42'-1 1/2" 12 BB1 Yes 9321-F-2069 03-26517 Y

X 4

3EXB-4 90-DEG ELBOW Scope Add 5

3EXB-10R REDUCER Scope Add 6

3EXC-2 90-DEG ELBOW 03_3RD POINT ES TO FWH 23C 20.000 0.250 0.250 0.000 0.000 50 15000 0.100 0.100 n/a REINSPECTION TH - 36' 42'-1 1/2" 12 BB1 Yes 9321-F-2069 03-26519 Y

X 7

4EXA-12 45-DEG ELBOW 04_4TH POINT ES TO FWH 24A 20.000 0.250 0.250 0.000 0.000 100 15000 0.117 0.117 n/a REINSPECTION TH - 36' 39'-6 11/16" 18 A Yes 9321-F-2068 03-26520 Y

X 8

4EXB-14P STRAIGHT PIPE 05_4TH POINT ES TO FWH 24B 20.000 0.250 0.250 0.000 0.000 100 12800 0.088 0.137 n/a Contingency Repair (WO# 03-26407)

TH - 36' 39'-6 11/16" 17 A Yes 9321-F-2068 03-26523 Y

X 9

4EXB-3P US STRAIGHT PIPE 05_4TH POINT ES TO FWH 24B 20.000 0.250 0.250 0.000 0.000 100 12800 0.137 0.137 n/a REINSPECTION TH - 36' 28'-0" 15 BB1 Yes 9321-F-2069 03-26524 X

10 4EXB-6 90-DEG ELBOW 05_4TH POINT ES TO FWH 24B 20.000 0.250 0.250 0.000 0.000 100 15000 0.117 0.117 n/a FAC Scope Assessment recommend TH - 15' 32' -0" 16 A Yes 9321-F-2069 03-26525 X

11 4EXB-7 90-DEG ELBOW 05_4TH POINT ES TO FWH 24B 20.000 0.250 0.250 0.000 0.000 100 15000 0.117 0.117 n/a FAC Scope Assessment recommend TH - 15' 24'-6" 16 A Yes 9321-F-2069 03-26526 X

12 4EXC-13P DS STRAIGHT PIPE 06_4TH POINT ES TO FWH 24C 20.000 0.250 0.250 0.000 0.000 100 12800 0.137 0.137 n/a REINSPECTION TH - 36' 39'-6 11/16" 15 A Yes 9321-F-2069 03-26527 X

13 4EXC-5 90-DEG ELBOW 06_4TH POINT ES TO FWH 24C 20.000 0.250 0.250 0.000 0.000 100 15000 0.117 0.117 n/a REINSPECTION TH - 15' 32' -0" 16 BB1 Yes 9321-F-2069 03-26528 X

14 5EXD-3P US STRAIGHT PIPE 09_FWH 25 DRNS TO HTR DRN TK 10.750 0.250 0.250 0.000 0.000 250 12800 0.150 0.150 n/a REINSPECTION TH - 15' 32' -0" 17 BB1 Yes 9321-F-2075 03-26529 X

15 6EXD-6 90-DEG ELBOW 12_FWH 26 TO CV 10.750 0.307 0.307 0.000 0.000 450 15000 0.183 0.183 n/a NEW INSPECTION TH - 15' 28'-0" 19 BB1 Yes 9321-F-2075 03-26531 16 6EXD-6P STRAIGHT PIPE 12_FWH 26 TO CV 10.750 0.307 0.307 0.000 0.000 450 15000 0.183 0.183 n/a NEW INSPECTION TH - 15' 28'-0" 19 BB1 Yes 9321-F-2075 03-26532 17 HD-9 CON. EXPANDER 20_HDP DISCH TO BFP SUCTION 12.750 0.500 0.322 8.625 0.000 730 15000 0.322 0.212 n/a REINSPECTION TH - 15' 13'-7" 19 BB1 Yes 9321-F-2056 03-26533 Y

X 18 4EXD-38 CON. EXPANDER 22A_CV TO FWH 23B 6.625 0.280 0.216 3.500 0.000 100 15000 0.104 0.078 n/a REINSPECTION/ REPLACED CS RFO 14 TH - 36' 38'-3" 12 BB1 Yes 9321-F-2076 03-26534 X

19 4EXD-39P STRAIGHT PIPE 22A_CV TO FWH 23B 3.500 0.215 0.215 0.000 0.000 100 15000 0.078 0.078 n/a FAC Scope Assessment recommend TH - 36' 38'-3" 12 BB1 Yes 9321-F-2076 03-26536 X

20 3EXD-6 90-DEG ELBOW 24A/B_FWH 23A DRN TO CV 8.625 0.250 0.250 0.000 0.000 50 15000 0.091 0.091 n/a NEW INSPECTION TH - 15' 30'-3" 14 A Yes 9321-F-2076 03-26537 Y

21 3EXD-6P STRAIGHT PIPE 24A/B_FWH 23A DRN TO CV 8.625 0.250 0.250 0.000 0.000 50 15000 0.091 0.091 n/a NEW INSPECTION TH - 15' 30'-3" 14 A Yes 9321-F-2076 03-26538 Y

22 3EXD-7 90-DEG ELBOW 24A/B_FWH 23A DRN TO CV 8.625 0.250 0.250 0.000 0.000 50 15000 0.091 0.091 n/a REINSPECTION TH - 15' 30'-3" 14 A Yes 9321-F-2076 03-26540 Y

X 23 3EXD-7P STRAIGHT PIPE 24A/B_FWH 23A DRN TO CV 8.625 0.250 0.250 0.000 0.000 50 15000 0.091 0.091 n/a NEW INSPECTION TH - 15' 30'-3" 14 A Yes 9321-F-2076 03-26541 Y

24 3EXD-8 90-DEG ELBOW 24A/B_FWH 23A DRN TO CV 8.625 0.250 0.250 0.000 0.000 50 15000 0.091 0.091 n/a NEW INSPECTION TH - 15' 28'-0" 14 A Yes 9321-F-2076 03-26542 Y

25 MS-1B25P STRAIGHT PIPE 48A/B_RDT 21B TO LCV 1105 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a REINSPECTION TH - 36' 47'-9" 15 B4 Yes 9321-F-2080 03-26544 X

26 MS-1B26 90-DEG ELBOW 48A/B_RDT 21B TO LCV 1105 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 36' 47'-9" 15 B4 Yes 9321-F-2080 03-26545 27 MS-1B41P-1 STRAIGHT PIPE 48 A/B_RDT 21B TO LCV 1105 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a CR#200300584 TH - 36' 40'-6" 15 B4 Yes 9321-F-2080 03-26546 X

28 MS-1B39 45-DEG ELBOW 48B_LCV 1105 TO HDR [2]

8.625 0.500 0.500 0.000 0.000 1085 15000 0.323 0.323 n/a WET STEAM REPLACEMENT TH - 15' 28'-0" 19 A Yes 9321-F-2081 03-26547 X

29 MS-1B39P STRAIGHT PIPE 48B_LCV 1105 TO HDR [2]

8.625 0.500 0.500 0.000 0.000 1085 15000 0.323 0.323 n/a NEW INSPECTION TH - 15' 28'-0" 19 A Yes 9321-F-2081 03-26549 30 MS-2B11P STRAIGHT PIPE 49A/B_RDT 22B TO LCV 1105A 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a REINSPECTION TH - 36' 49'-10" 16 F Yes 9321-F-2080 03-26550 X

31 MS-2B14P STRAIGHT PIPE 49A/B_RDT 22B TO LCV 1105A 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a REINSPECTION TH - 36' 49'-10" 16 F Yes 9321-F-2080 03-26551 X

32 MS-2B15 90-DEG ELBOW 49A/B_RDT 22B TO LCV 1105A 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 36' 49'-10" 16 F Yes 9321-F-2080 03-26552 33 MS-2B15P STRAIGHT PIPE 49A/B_RDT 22B TO LCV 1105A 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 36' 49'-10" 16 F Yes 9321-F-2080 03-26553 34 MS-2B55N EXIT NOZZLE 49C_HDR [2] TO FWH 26A,B,C 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 36' 42'-9" 19 CC3 Yes 9321-F-2079 03-26556 35 MS-2B55R CON. EXPANDER 49C_HDR [2] TO FWH 26A,B,C 8.625 0.500 0.432 6.625 0.000 1085 15000 0.323 0.264 n/a REINSPECTION TH - 36' 42'-9" 19 CC3 Yes 9321-F-2079 03-26557 X

36 MS-2B55P STRAIGHT PIPE 49C_HDR [2] TO FWH 26A,B,C 10.750 0.594 0.594 0.000 0.000 1085 15000 0.323 0.323 n/a NEW INSPECTION TH - 36' 42'-9" 19 CC3 Yes 9321-F-2079 03-26558 37 MS-2B55 TEE 49C_HDR [2] TO FWH 26A,B,C 10.750 0.594 0.594 10.750 0.594 1085 15000 0.323 0.323 0.323 NEW INSPECTION TH - 36' 42'-9" 19 CC3 Yes 9321-F-2079 03-26555 38 MS-3B25 90-DEG ELBOW 50A_RDT 23B TO LCV 1105B 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 15' 25'-8" 14 D1 Yes 9321-F-2080 03-26560 39 MS-3B25P STRAIGHT PIPE 50A_RDT 23B TO LCV 1105B 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a NEW INSPECTION TH - 15' 25'-8" 14 D1 Yes 9321-F-2080 03-26561 40 MS-3B26 90-DEG ELBOW 50A_RDT 23B TO LCV 1105B 6.625 0.432 0.432 0.000 0.000 1085 15000 0.264 0.264 n/a REINSPECTION/ REPLACED CS RFO 13 TH - 15' 25'-8" 14 D1 Yes 9321-F-2080 03-26562 X

41 MS-3B43P US STRAIGHT PIPE 50C_LCV 1105B TO HDR [2]

8.625 0.500 0.500 0.000 0.000 1085 15000 0.323 0.323 n/a REINSPECTION TH - 36' 38'-9" 19 A Yes 9321-F-2081 03-26563 X

42 MS46-5 90-DEG ELBOW 51_SGBD PEN TO VALVE MS-71A 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a REINSPECTION PAB-51' 60'-6" 6.1 EE Yes 9321-F-2559 03-26564 X

43 MS46-5P STRAIGHT PIPE 51_SGBD PEN TO VALVE MS-71A 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a NEW INSPECTION PAB-51' 60'-6" 6.1 EE Yes 9321-F-2559 03-26565 44 MS46-6 45-DEG ELBOW 51_SGBD PEN TO VALVE MS-71A 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a NEW INSPECTION PAB-51' 60'-6" 6.1 EE Yes 9321-F-2559 03-26566 45 MS46-6P STRAIGHT PIPE 51_SGBD PEN TO VALVE MS-71A 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a NEW INSPECTION PAB-51' 60'-6" 6.1 EE Yes 9321-F-2559 03-26567 46 BFD-9 90-DEG ELBOW 71/72_BFP DISCHARGE TO HEADER 20.000 1.031 1.031 0.000 0.000 1440 15000 0.924 0.924 n/a NEW INSPECTION TH - 15' 24'-6" 17 CC3 Yes 9321-F-2064 03-26570 47 BFD-9P STRAIGHT PIPE 71/72_BFP DISCHARGE TO HEADER 20.000 1.031 1.031 0.000 0.000 1440 15000 0.924 0.924 n/a NEW INSPECTION TH - 15' 24'-6" 17 CC3 Yes 9321-F-2064 03-26571 48 BFD-11 TEE 71/72_BFP DISCHARGE TO HEADER 30.000 1.260 1.260 20.000 1.031 1440 15000 1.195 1.195 0.924 NEW INSPECTION TH - 15' 32'-0" 17 CC3 Yes 9321-F-2064 03-26572 49 BFD-23 90-DEG ELBOW 73_BFP HEADER TO FWH 26A,B,C 30.000 1.260 1.260 20.000 1.031 1440 15000 1.195 1.195 n/a Time to Tcrit per CW models TH - 15' 32'-0" 17 CC3 Yes 9321-F-2064 03-26574 X

50 BFD-23P STRAIGHT PIPE 73_BFP HEADER TO FWH 26A,B,C 30.000 1.260 1.260 20.000 1.031 1440 15000 1.195 1.195 n/a Time to Tcrit per CW models TH - 15' 32'-0" 17 CC3 Yes 9321-F-2064 03-26575 X

51 BFD-23R CON. EXPANDER 73_BFP HEADER TO FWH 26A,B,C 30.000 1.260 1.031 20.000 0.000 1440 15000 1.195 0.924 n/a NEW INSPECTION TH - 15' 32'-0" 17 CC3 Yes 9321-F-2064 03-26576 52 BFD-39N INLET NOZZLE 73_BFP HEADER TO FWH 26A,B,C 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a REINSPECTION TH - 36' 36' 19 CC3 Yes 9321-F-2063 03-26577 X

53 BFD-55P STRAIGHT PIPE 74_FWH 26A,B,C HEADER 18.000 0.938 0.938 0.000 0.000 1440 17500 0.717 0.717 n/a ASSESSMENT INSPECTION TH - 36' 45'-0" 19 CC3 Yes 9321-F-2063 03-26578 X

54 BFD-56 90-DEG ELBOW 74_FWH 26A,B,C HEADER 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a REINSPECTION TH - 36' 45'-0" 19 CC3 Yes 9321-F-2063 03-26579 X

55 BFD-56P STRAIGHT PIPE 74_FWH 26A,B,C HEADER 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a NEW INSPECTION TH - 36' 45'-0" 19 CC3 Yes 9321-F-2063 03-26581 56 BFD-56P-1 STRAIGHT PIPE 74_FWH 26A,B,C HEADER 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a NEW INSPECTION TH - 15' 34'-9" 19 CC3 Yes 9321-F-2063 03-26582 57 BFD-57 90-DEG ELBOW 74_FWH 26A,B,C HEADER 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a Time to Tcrit per CW models TH - 15' 34'-9" 19 CC3 Yes 9321-F-2063 03-26583 X

58 BFD-69P STRAIGHT PIPE 75/76_HEADER TO CON PEN E,F 18.000 0.938 0.938 0.000 0.000 1440 17500 0.717 0.717 n/a Inspect DS of LEFM (1ft length of pipe)

AFB-15' 35'-0" 22 H9 Yes 9321-F-2061 03-26584 X

59 BFD-71R CON. EXPANDER 75/76_HEADER TO CON PEN E,F 18.000 0.937 0.843 12.750 0.000 1440 15000 0.832 0.589 n/a REINSPECTION TH - 15' 22'-3" 23 H9 Yes 9321-F-2061 03-26585 X

60 BFD-71 90-DEG ELBOW 75/76_HEADER TO CON PEN E,F 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a NEW INSPECTION TH - 15' 22'-3" 23 H9 Yes 9321-F-2061 03-26586 61 BFD-89P STRAIGHT PIPE 77/78_HEADER TO CON PEN G,H 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a NEW INSPECTION TH - 15' 22'-3" 23 H9 Yes 9321-F-2061 03-26587 62 BFD-89 90-DEG ELBOW 77/78_HEADER TO CON PEN G,H 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a REINSPECTION TH - 15' 22'-3" 23 H9 Yes 9321-F-2061 03-26588 X

63 BFD-89P-1 STRAIGHT PIPE 77/78_HEADER TO CON PEN G,H 18.000 0.938 0.938 0.000 0.000 1440 15000 0.832 0.832 n/a NEW INSPECTION TH - 15' 22'-3" 23 H9 Yes 9321-F-2061 03-26589 64 CD-19 90-DEG ELBOW 80_FWH 23 COND TO FWH 24 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a REINSPECTION TH - 15' 28'-0" 15 BB1 Yes 9321-F-2055 03-26590 Y

X 65 CD-19P STRAIGHT PIPE 80_FWH 23 COND TO FWH 24 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a NEW INSPECTION TH - 15' 28'-0" 15 BB1 Yes 9321-F-2055 03-26591 Y

66 CD-22 90-DEG ELBOW 80_FWH 23 COND TO FWH 24 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a REINSPECTION TH - 15' 28'-0" 15 BB1 Yes 9321-F-2055 03-26592 Y

X 67 CD-42 90-DEG ELBOW 80_FWH 23 COND TO FWH 24 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a NEW INSPECTION TH - 36' 41'-0" 15 BB1 Yes 9321-F-2055 03-26593 Y

68 CD-42N INLET NOZZLE 80_FWH 23 COND TO FWH 24 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a Time to Tcrit per CW models TH - 36' 41'-0" 15 BB1 Yes 9321-F-2055 03-26594 Y

X 69 CD-20 90-DEG ELBOW 81_FWH 24 COND TO FWH 25 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a REINSPECTION TH - 36' 45'-0" 15 BB1 Yes 9321-F-2055 03-26595 Y

X 70 CD-23 90-DEG ELBOW 81_FWH 24 COND TO FWH 25 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a REINSPECTION TH - 36' 45'-0" 15 BB1 Yes 9321-F-2055 03-26596 Y

X 71 CD-23P STRAIGHT PIPE 81_FWH 24 COND TO FWH 25 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a NEW INSPECTION TH - 36' 45'-0" 15 BB1 Yes 9321-F-2055 03-26597 Y

72 CD-24 90-DEG ELBOW 81_FWH 24 COND TO FWH 25 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a REINSPECTION TH - 36' 45'-0" 15 BB1 Yes 9321-F-2055 03-26598 Y

X 73 CD-53 90-DEG ELBOW 81_FWH 24 COND TO FWH 25 14.000 0.438 0.438 0.000 0.000 665 15000 0.305 0.305 n/a Time to Tcrit per CW models TH - 15' 33'-0" 15 BB1 Yes 9321-F-2055 03-26599 Y

X 74 CD-80T TEE 81_FWH 24 COND TO FWH 25 30.000 0.626 0.626 30.000 0.626 665 17500 0.561 0.561 0.561 Time to Tcrit per CW models TH - 15' 24'-6" 14 BB1 Yes 9321-F-2057 03-26600 Y

X 75 CD-82T TEE 82/83_FWH 25 TO HEADER 30.000 0.626 0.000 24.000 0.688 665 17500 0.561 0.561 0.449 REINSPECTION TH - 15' 24'-6" 14 BB1 Yes 9321-F-2057 03-26601 X

76 CD-69P STRAIGHT PIPE 83/84_HEADER TO BFP SUCTION 24.000 0.688 0.688 0.000 0.000 665 15000 0.523 0.523 n/a REINSPECTION TH - 15' 32'-0" 14 CC3 Yes 9321-F-2057 03-26602 X

79 CD-72P PIPE Scope Add; Mihama 80 CD-76P PIPE Scope Add; Mihama 81 206-6P STRAIGHT PIPE NCW_206(MS DUMPS TO CONDENSER) 10.75 0.594 0.594 0.000 0.000 1085 15000 0.392 0.392 n/a NEW INSPECTION TH - 15' 35'-8" 17 D6 Yes 9321-F-2052 03-26603 Page 1 ENT000060 Submitted: March 28, 2012

2R16 FAC MASTER INSPECTION LIST (MIL)

No.

Component Name Component Geometry Type Line Name OD (U/S Main/

Large End)

Tnom (U/S Main/

Large End)

Tnom (D/S Main/

Small End)

OD (Small or Branch)

Tnom (Tee Branch)

Design Pressure Material Allowable Tmin req (U/S Main/

Large End)

Tmin req (D/S Main/

Small End)

Tmin req (Tee Branch)

Comments Building/

Bldg Elev.

Component Elevation Bldg Col Bldg Row Insul (Y/N)

Ref Dwg WO#

(IP2- )

Pre-outage Priority Scaffold (Y/N) 82 206-7E 90-DEG EXP. ELBOW NCW_206(MS DUMPS TO CONDENSER) 10.75 0.594 0.500 8.825 0.000 1085 15000 0.392 0.323 n/a Upstream valve (MS-5) leakby (CR# 200112338)

TH - 15' 35'-8" 17 D6 Yes 9321-F-2052 03-26604 X

83 213-4P STRAIGHT PIPE NCW_213 (

6.625 0.864 0.864 0.000 0.000 1440 15000 0.447 0.447 n/a CR# 200300118 TH - 15' 24'-7 1/2" 13 C4 Yes 9321-F-2066 03-26605 X

84 214-25P STRAIGHT PIPE NCW_214 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a REINSPECTION TH-53' 54'-0" 16 A Yes A209848 03-26606 Y

X 85 219-11P US STRAIGHT PIPE NCW_219 12.750 0.375 0.375 0.000 0.000 221 12800 0.202 0.202 n/a REINSPECTION TH - 15' 28'-2" 16 F Yes A227308 03-26607 X

86 227-2C END CAP NCW_227 10.750 0.365 0.365 0.000 0.000 221 15000 0.161 0.161 n/a REINSPECTION TH - 36' 32'-0 19 D2 Yes 03-26608 X

87 228-17E 90-DEG ELBOW NCW_228 2.375 0.218 0.218 0.000 0.000 1085 15000 0.116 0.116 n/a REINSPECTION TH-53' 38'-8" 17 F Yes 03-26609 Y

X 88 235-2E 90-DEG ELBOW NCW_235 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Large Bore Non-CW deferred from 2R15 TH - 36' 32'-0" 19 C6 Yes 03-26610 X

89 4EXD-74 90-DEG ELBOW NCW_23B 6.625 0.280 0.280 0.000 0.000 100 15000 0.104 0.104 n/a REINSPECTION TH - 15' 32' -0" 16 A Yes 9321-F-2076 03-26611 X

90 248-13T TEE NCW_248 4.500 0.337 0.337 3.500 0.216 1085 15000 0.194 0.194 0.135 REINSPECTION TH - 15' 16 A 03-26612 X

91 259-3E 90-DEG ELBOW NCW_259 4.500 0.337 0.337 0.000 0.000 1085 15000 0.194 0.194 n/a REINSPECTION TH-53' 20 C2 03-26613 X

92 267-29E 90-DEG ELBOW NCW_267 6.625 0.280 0.280 0.000 0.000 1085 15000 0.233 0.233 n/a NEW INSPECTION TH - 36' 17 F 03-26614 93 267-30P STRAIGHT PIPE NCW_267 6.625 0.280 0.280 0.000 0.000 1085 15000 0.233 0.233 n/a NEW INSPECTION TH - 36' 17 F 03-26615 94 267-31R CON. EXPANDER NCW_267 6.625 0.280 0.216 3.500 0.000 1085 15000 0.233 0.135 n/a REINSPECTION TH - 36' 17 F 03-26616 X

95 267-32E 90-DEG ELBOW NCW_267 6.625 0.280 0.280 0.000 0.000 1085 15000 0.233 0.233 n/a REINSPECTION TH - 36' 17 F 03-26617 X

96 273-10E 90-DEG ELBOW NCW_273 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Replaced A234 Grade WP22, Sch. 40 TH - 36' 03-26618 Y

X 97 285-15P US STRAIGHT PIPE NCW_285 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Replaced A335 Grade P22, Sch. 40 TH - 15' 03-26619 X

98 MS-1A1*

90-DEG ELBOW NCW_39 2.875 0.276 0.276 0.000 0.000 1085 15000 0.144 0.144 n/a REINSPECTION TH-53' 59'-3" 14 A9 Yes 9321-F-2080 03-26620 X

99 MS-1A2P STRAIGHT PIPE NCW_39 2.875 0.276 0.276 0.000 0.000 1085 15000 0.144 0.144 n/a NEW INSPECTION TH-53' 59'-3" 14 A9 Yes 9321-F-2080 03-26623 100 MS-1A2 90-DEG ELBOW NCW_39 2.875 0.276 0.276 0.000 0.000 1085 15000 0.144 0.144 n/a NEW INSPECTION TH-53' 59'-3" 14 A9 Yes 9321-F-2080 03-26624 101 2A-VCD42 90-DEG ELBOW NCW_66A 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Replaced A234 Grade WP22, Sch. 40 TH-36' 46'-6" 15.7 B4 Yes A209849 03-26625 Y

X 102 1B-VCD17 90-DEG ELBOW NCW_68A 3.500 0.216 0.216 0.000 0.000 1085 15000 0.080 0.080 n/a Replaced A234 Grade WP22, Sch. 40 TH-53' 54'0" 15 E1 Yes A209848 03-26626 Y

X 103 1B-VCD19E 90-DEG ELBOW NCW_68A 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Replaced A234 Grade WP22, Sch. 40 TH-53' 54'0" 15 E1 Yes A209848 03-26627 Y

X 104 2B-VCD8E 90-DEG ELBOW NCW_69A 3.500 0.216 0.216 0.000 0.000 1085 15000 0.135 0.135 n/a Replaced A234 Grade WP22, Sch. 40 TH-53' 54'0" 16 E1 Yes A209848 03-26628 Y

X 105 GCD-2 TEE NCW_85 8.625 0.322 0.322 0.000 0.000 665 15000 0.203 0.203 0.203 REINSPECTION TH-36' 38'-3" 15 E1 No 9321-F-2054 03-26629 Y

X No 106 MST24-Pipe 2 US STRAIGHT PIPE NCW_Main Steam Traps 1.315 0.179 0.179 0.000 0.000 1085 15000 0.083 0.083 n/a Contingency Repair (WO# 03-26438)

TH - 15' Yes 03-26634 Y

X No 107 FWH 24A 6' X10' SHELL SECTION 85-H-104-4-1_FWH 24A, B & C 51.875 0.4375 0.4375 0

0 100 17500 0.199 0.199 n/a FWH Shell inspection (WO# 03-14297)

TH-36' Yes 03-14297 X

Yes 108 FWH 24B 6' X10' SHELL SECTION 85-H-104-4-1_FWH 24A, B & C 51.875 0.4375 0.4375 0

0 100 17500 0.199 0.199 n/a FWH Shell inspection (WO# 03-14296)

TH-36' Yes 03-14296 X

Yes 109 FWH 24C 6' X10' SHELL SECTION 85-H-104-4-1_FWH 24A, B & C 51.875 0.4375 0.4375 0

0 100 17500 0.199 0.199 n/a FWH Shell inspection (WO# 03-14295)

TH-36' Yes 03-14295 X

Yes 110 LPFW22C-1N INLET NOZZLE 4427D26_22" LP EXT TO FWH 22C 22 0.375 0.375 0

0 50 12800 0.043 0.043 n/a Contingency Repair (WO# 03-26636)

TH-36' Yes 02-52403 X

Yes 111 LPFW22C-2N INLET NOZZLE 4427D26_22" LP EXT TO FWH 22C 22 0.375 0.375 0

0 50 12800 0.043 0.043 n/a Contingency Repair (WO# 03-26637)

TH-36' Yes 02-52414 X

Yes 112 MST-49 STRAIGHT PIPE MAIN STEAM TRAP 1.315 0.179 0.179 0.000 0.000 1085 15000 0.083 0.083 n/a Inspection per CR# 200207585 TH-36' 36'-9" 14 F Yes 9321-F-2131 03-26630 Y

X 113 EST-18 STRAIGHT PIPE EXTRACTION STEAM TRAP 1.050 0.113 0.113 0.000 0.000 100 15000 0.039 0.039 n/a Inspection per CR# 200211573/11169 TH - 15' Yes 03-26631 Y

X 114 DS-FE-419 STRAIGHT PIPE 2017_Main Steam 28.000 0.912 0.912 0.000 0.000 1085 17500 0.847 0.847 n/a Inspection per LO-OEN-2003-00111 VC-95' Yes 03-26632 X

115 5EX-59EJ1 EXPANSION JOINT 56_MAIN STM F/PRESEP TO A MSRS 27.500 0.500 0.500 0.000 0.000 250 13800 0.247 0.247 n/a Internal Visual Inspection (CR#200304797)

TH-36' 49'-9" 16 A9 Yes B227128 03-26633 X

Yes 116 22BFPT SHELL SECTION NCW_215 0.62 0.62 0

0 vac Inspection per CR# 200211640 TH-5' 16 A No 03-26635 X

Yes 117 MS-2B33P STRAIGHT PIPE SK-49C Replaced A335 Grade P22, Seamless, Sch. 80 118 MS-2B35 90-DEGREE ELBOW SK-49C Replaced A234 Grade WP22, Sch. 80 119 MS--2B35P STRAIGHT PIPE SK-49C Replaced A335 Grade P22, Seamless, Sch. 80 120 MS-2B36 90-DEGREE ELBOW SK-49C Replaced A234 Grade WP22, Sch. 80 28 69 CW - CHECWORKS LPFWH - Low Pressure Feedwater Heater Tcrit - Minimal Allowable thickness 2R16 WET STM REPLACEMENT - Components will not be inspected if replaced as part of the 2R16 Wet Steam Pipe Replacement Project.

Descoped Components do not exist Replaced Visual inspection Pre-outage Page 2

FAC 2R15 ONLINE MASTER INSPECTION LIST (MIL)

Page 1 MIL Number FAC Program Component Name Geometry Type Diameter Line Name Elev Bulding Comments Ref. Drawings FAC Drawing Online Inspection Priority Scaffolding Insulation 1

3EXB-4P STRAIGHT PIPE 20" 02_3RD POINT ES TO FWH 23B 26'-2" TH Contingency Replacement. Inspection of entire straight run.

9321-F-6069 SK-2 Y

1 10' HIGH Blanket 2

5EXD-14P STRAIGHT PIPE 10" 09_FWH 25 DRNS TO HTR DRN TK 17'-6" TH Contingency Replacement. Inspection of entire straight run.

9321-F-2075 SK-9 Y

1 NONE Blanket 3

5EXD-18P STRAIGHT PIPE 10" 09_FWH 25 DRNS TO HTR DRN TK 17'-6" TH Contingency Replacement. Inspection of entire straight run.

9321-F-2075 SK-9 Y

1 NONE JACKET 4

5EXD-20P STRAIGHT PIPE 10" 09_FWH 25 DRNS TO HTR DRN TK 17'-6" TH Contingency Replacement. Inspection of entire straight run.

9321-F-2075 SK-9 Y

1 NONE Blanket 5

5EXC-1 ELBOW 24" 18_DRNS FROM HTR DR TK TO CONDS 12'-6" TH 9321-F-2075 SK-18 Y

1 NONE NONE 6

5EXC-21P-1 STRAIGHT PIPE 14" 18_DRNS FROM HTR DR TK TO CONDS 12'-6" TH 9321-F-2075 SK-18 Y

1 NONE NONE 7

5EXC-25 REDUCER 14" X 10" 18_DRNS FROM HTR DR TK TO CONDS 16'-5 5/8" TH 9321-F-2078 SK-18 Y

1 NONE NONE 8

4EXD-4 TEE 6" X 6" X 6" 21A_CV TO FWH 23A 38'-3" TH Inspection should include UT of blank flange 9321-F-2078 SK-21A Y

1 NONE BLANKET 9

4EXD-6P STRAIGHT PIPE 3"

21A_CV TO FWH 23A 38'-3" TH 9321-F-2078 SK-21A Y

1 NONE BLANKET 10 4EXD-36 CON. EXPANDER 3" X 6" 21B_FWH 23A TO COND 23 17'-10" TH Plant Experience inspection - Upstream valve (lcv-1115A) has been leaking by..

9321-F-2078 SK-21B Y

1 11 4EXD-37 TEE 6" X 6" X 6" 22A_CV TO FWH 23B 38'-3" TH Inspection should include UT of blank flange 9321-F-2078 SK-22A Y

1 NONE Blanket 12 4EXD-60 REDUCER 4" X 3" 23A_FWH 24C DRN TO CV 38'-3" TH Neg Time to Tcrit based on CHECWORKS analysis 9321-F-2078 SK-23A Y

1 NONE Blanket 13 3EXD-56 TEE 8"

26B_FWH 23C TO COND 21 17'-10" TH Inspection should include blank flange UT.

9321-F-2078 SK-26B Y

1 NONE Blanket 14 MS-1A3P STRAIGHT PIPE 2-1/2" 39_MSRHT 21A VENT TO MSHTR 21A 59'-6" TH 9321-F-2086 SK-39 Y

1 PLATF BLANKET 15 1B-VCD17 90-DEG ELBOW 3"

68A_VENT CHAMBER DR TO COND 21 54'-0" TH VCD Line #823 A209851 SK-68A Y

1 NONE Blanket 16 1B-VCDXE 90-DEG ELBOW 3"

68A_VENT CHAMBER DR TO COND 21 33'-4" TH Line #823. Last elbow before Cond.

A226903 A226903 Y

1 NONE ACM 17 2B-VCD39 90-DEG ELBOW 3"

69A_VENT CHAMBER DR TO COND 21 54'-0" TH Downstream of MS-618. VCD Line #822 A209851 SK-69A Y

1 PLATF JACKET 18 CD-11 90-DEG ELBOW 14" 80_FWH 23 COND TO FWH 24 45'-0" TH 9321-F-2058 SK-80 Y

1 3-4' HI Blanket 19 CD-11N EXIT NOZZLE 14" 80_FWH 23 COND TO FWH 24 45'-0" TH Neg Time to Tcrit. Inspect with D/S elbow 9321-F-2058 SK-80 Y

1 20 GCD-1P STRAIGHT PIPE 8"

85_GS COND FROM FCV-1113 TO COND 38'-3" TH Inspect entire pipe run.

9321-F-2054 SK-85 Y

1 NONE NONE 21 224-12P STRAIGHT PIPE 12" 224_FWH 22C DUMP TO COND 10'-0" TH Plant Experience-U/S valve LCV-1123A was passing flow last year.

A235304 SK-224 Y

1 22 239-3E 90-DEG ELBOW 2"

239_FWH 23B VENT TO HDR 41'-4" TH 9321-F-2076 SK-239 Y

1 NONE JACKET 23 273-10E 90-DEG ELBOW 3"

273_VENT CHAMBER DR TO COND 21 39'-5" TH Line #822.

A226903 SK-273 Y

1 4' HIGH JACKET 24 COMP2 90-DEG ELBOW 2"

MAIN STEAM SUPPLY TO SJEA 39'-8 1/4" TH Elbow upstream of valve MS-10 9321-F-2053 P&ID_227780 Y

1 NONE 25 4EXD-35 0-DEG RED. ELBOW 3" X 6" 21B_FWH 23A TO COND 23 17'-10" TH 9321-F-2078 SK-21B Y

2 NONE Jacket 26 2A-VCD-42 ELBOW 3"

66A_VENT CHAMBER DR TO COND 21 39'-5" TH Last elbow before Cond. 21. VCD Line #825 A226903 SK-66A Y

2 NONE JACKET 27 CD-43N INLET NOZZLE 14" 80_FWH 23 COND TO FWH 24 38'-2 9/16" TH Highly Ranked by CHEWORKS.

9321-F-2058 SK-80 Y

2 NONE JACKET 28 214-26E 90-DEG ELBOW 2"

214_RHT STM CONTRL LEAKOFF 54'-0" TH Inspect entire run of component 214-25P.

A209848 SK-214 Y

2 29 215-2E 90-DEG ELBOW 2"

215_BFP TURB DR TO BFP DR TK 5'-0" TH 9321-H-2024 SK-215 Y

2 6' HIGH NONE

FAC 2R15 ONLINE MASTER INSPECTION LIST (MIL)

Page 2 30 215-10E 90-DEG ELBOW 2"

215_BFP TURB DR TO BFP DR TK 5'-0" TH 9321-H-2024 SK-215 Y

2 2-4' HIGH NONE 31 219-11E 90-DEG ELBOW 12" 219_XUNDER DUMP LINE TO COND 22 28'-2" TH A227308 SK-219 Y

2 12-15' HI JACKET 32 263-6R EXPANDER 3" X 6" 263_GLAND SEAL STM SUPPLY 38'-9" TH Expander D/S of valve MS-584. Can be inspected when MS-584 packing leak is fixed (WO 02-02801).

9321-F-2082 SK-263 Y

2 NONE Blanket 33 273-8E ELBOW 3"

273_VENT CHAMBER DR TO COND 21 44'-11" TH VCD Line #822.

A226903 SK-273 Y

2 NONE JACKET 34 EST-2 STEAM TRAP 3/4" EXTRACTION STEAM TRAPS 16'-0" TH Piping from trap up to and including second elbow.

9321-F-2151 9321-F-2151 Y

2 NONE JACKET 35 EST-4 STEAM TRAP 1"

EXTRACTION STEAM TRAPS 16'-0" TH Piping from trap up to and including second elbow.

9321-F-2151 9321-F-2151 Y

2 NONE JACKET 36 EST-5 STEAM TRAP 3/4" EXTRACTION STEAM TRAPS 16'-0" TH Piping from trap up to and including second elbow.

9321-F-2151 9321-F-2151 Y

2 NONE JACKET 37 MST-24 STEAM TRAP 1"

MAIN STEAM TRAPS 15'-0" TH Piping from trap up to and including tee 9321-F-2130 9321-F-2130 Y

2 NONE JACKET 38 MST-27 STEAM TRAP 1-1/4" MAIN STEAM TRAPS 15'-0" TH Piping from trap up to and including tee 9321-F-2130 9321-F-2130 Y

2 NONE JACKET 39 MST-43 STEAM TRAP 1-1/4" MAIN STEAM TRAPS 12'-0" TH Piping from trap up to and including tee 9321-F-2131 9321-F-2131 Y

2 NONE JACKET 40 MST-44 STEAM TRAP 1-1/4" MAIN STEAM TRAPS 12'-0" TH Piping from trap up to and including tee 9321-F-2131 9321-F-2131 Y

2 NONE JACKET 41 MST-45 STEAM TRAP 1-1/4" MAIN STEAM TRAPS 12'-0" TH Piping from trap up to and including tee 9321-F-2131 9321-F-2131 Y

2 NONE JACKET 42 MST-46 STEAM TRAP 1"

MAIN STEAM TRAPS 12'-0" TH Piping from trap up to and including tee 9321-F-2131 9321-F-2131 Y

2 NONE JACKET 43 MST-50 STEAM TRAP 1"

MAIN STEAM TRAPS 36'-9" TH Pipe from trap up to and including 2nd tee 9321-F-2131 9321-F-2131 Y

2 NONE JACKET 44 MST-51 STEAM TRAP 1"

MAIN STEAM TRAPS 36'-9" TH Pipe from trap up to and including 2nd tee 9321-F-2131 9321-F-2131 Y

2 NONE Blanket 45 MS-100-2 BYPASS VALVE 1"

MAIN STEAM TRAP BYPASS VALVE 19'-3" TH Bypass valve for MST-24. Pipe D/S of valve to tee 9321-F-2130 9321-F-2130 Y

2 NONE JACKET 46 HV21C-1E ELBOW 5"

A235304_Heater 21C Vent to Condenser First elbow downstream of Heater 21C. Component in Condenser. No Isometric A235304 A235304 Y

2 JACKET 47 AS-US-CONDR24 ELBOW 4"

F2027_Aux. Steam Condensate Drains 22'-8" TH First elbow Upstream of Condensate receiver 24.

9321-F-4018 9321-F-2027 Y

2 6' HIGH JACKET 48 ABF-DS-AF138 PIPE/EXPANDER 2" X 2-1/2" F2120_Feedwater Supply to Service Boiler 61'-8" HSB Expander and pipe downstream of AF-138.

9321-F-2122 9321-F-2120 Y

2 6' HIGH JACKET