ML15223A450

From kanterella
Jump to navigation Jump to search
NRC000205 - Indian Point, Unit 2, Updated Final Safety Analysis Report (Ufsar), Rev. 25, Chapter 3 - Reactor (2014)
ML15223A450
Person / Time
Site: Indian Point  
Issue date: 08/10/2015
From:
NRC/OGC
To:
SECY RAS
References
RAS 28141, ASLBP 07-858-03-LR-BD01, 50-247-LR, 50-286-LR
Download: ML15223A450 (94)


Text

NRC000205 Submitted: August 10, 2015 IP2 FSAR UPDATE CHAPTER 3 REACTOR

3.0 DESCRIPTION

The reactor core has a number of fuel regions with fuel assemblies arranged in a zone and/or checkered core pattern. The fuel rods are cold worked Zircaloy or ZIRLOTM tubes containing slightly enriched uranium-dioxide fuel.

The fuel assembly is a canless type with the basic assembly consisting of the rod cluster control guide thimbles attached to the grids and the top and bottom nozzles. The fuel rods are held by the spring clip grid in this assembly, which provides support for the fuel rods.

High parasitic (HIPAR) fuel was used for the initial fuel and reload fuel through Cycle 4. Low parasitic (LOPAR) fuel was loaded for Cycles 5 through 9, and optimized fuel assemblies (OFA) were loaded for Cycles 10, 11, and 12. For Cycles 13, 14 and 15, 15x15 VANTAGE+ fuel assemblies were loaded as the feed fuel. For Cycle 16, 15x15 Vantage + fuel assemblies with Performance + enhancements are loaded as feed fuel. For Cycle 17 thru 22 15x15 Upgraded fuel design assemblies have been loaded as feed fuel.

Rod cluster control assemblies and wet annular burnable absorber rods are inserted into the guide thimbles of the fuel assemblies. The absorber sections of the control rods are fabricated of silver-indium-cadmium alloy sealed in stainless steel tubes.

The control rod drive mechanisms for the full-length rod cluster control assemblies are of the magnetic latch type. The latches are controlled by three magnetic coils. They are so designed that upon a loss of power to the coils, the rod cluster control assembly is released and falls by gravity to shut down the reactor.

3.1 DESIGN BASES 3.1.1 Performance Objectives The reactor thermal power analyzed is 3216 MWt (3230 MWt total NSSS power), which is the licensed power rating. Calculations and operating experience indicate that hot channel factors will be considerably less than those used for design purposes in this application.

The initial reactor core fuel loading and programming were designed to yield the first cycle average burnup of 16,100 MWd/metric ton uranium (MTU). Cycles 2 through 4 reload designs yielded an average cycle burnup of 10,000 MWd/metric ton uranium, and Cycles 5 through 10 yielded an average cycle burnup of 13,500 MWd/metric ton uranium. Cycles 11, 12, and 13 achieved burnups of 18,094 MWd/MTU, 20,674 MWd/MTU, and 21,650 MWd/MTU, all of which included coastdown operation. Cycle 14 achieved a cycle burnup of 18,970 MWd/MTU. Cycle 15 achieved a cycle burnup of 22,110 MWd/MTU. Cycle 16 achieved a cycle burnup of 23,950 MWd/MTU with a coastdown. Cycle 17 achieved a cycle burnup of 18,708 MWd/MTU. Cycle 18 achieved a cycle burnup of 24,456 MWd/MTU. Cycle 19 achieved a burnup of 24,844 MWd/MTU. Cycle 20 achieved a cycle burnup of 23,740 MWd/MTU. Cycle 21 is expected to achieve a cycle burnup of 25,274 MWd/MTU. Cycle 22 is designed to achieve a cycle burnup of 25,103 MWd/MTU. The fuel rod cladding is designed to maintain its integrity for the anticipated core life. The effects of gas release, fuel dimensional changes, and corrosion-induced or irradiation-induced changes in the mechanical properties of cladding are considered in the design of the fuel assemblies.

Chapter 3, Page 1 of 94 Revision 25, 2014

IP2 FSAR UPDATE Rod cluster control assemblies are employed to provide sufficient reactivity control to terminate any credible power transient prior to reaching the minimum departure from nucleate boiling ratio (DNBR). This is accomplished by ensuring sufficient cluster control worth to shut the reactor down by at least 1.3-percent throughout core life in the hot condition with the most reactive cluster control stuck in the fully withdrawn position. Redundant equipment is provided to add soluble poison to the reactor coolant in the form of boric acid to maintain shutdown margin when the reactor is cooled to ambient temperatures.

Experimental measurements from critical experiments or operating reactors, or both, are used to validate the methods employed in the design. During design, nuclear parameters have been calculated for every phase of operation of the first core and reload cycles and, where applicable, are compared with design limits to show that an adequate margin of safety exists.

In the thermal hydraulic design of the core, the maximum fuel and clad temperatures during normal reactor operation and at overpower conditions have been conservatively evaluated and found to be consistent with safe operating limitations.

3.1.2 Principal Design Criteria 3.1.2.1 Reactor Core Design Criterion: The reactor core with its related controls and protection systems shall be designed to function throughout its design lifetime without exceeding acceptable fuel damage limits, which have been stipulated and justified. The core and related auxiliary system designs shall provide this integrity under all expected conditions of normal operation with appropriate margins for uncertainties and for specified transient situations, which can be anticipated. (GDC 6)

The reactor core, with its related control and protection system, is designed to function throughout its design lifetime without exceeding acceptable fuel damage limits. The core design, together with reliable process and decay heat removal systems, provides for this capability under all expected conditions of normal operation with appropriate margins for uncertainties and anticipated transient situations, including the effects of the loss of reactor coolant flow (Section 14.1.6), trip of the turbine generator (Section 14.1.8), loss of normal feedwater (Section 14.1.9), and loss of all offsite power (Section 14.1.12). The reactor protection system is designed to actuate a reactor trip for any anticipated combination of plant conditions, when necessary, to ensure a minimum departure from nucleate boiling (DNB) ratio equal to or greater than the applicable safety analysis limit DNBR.

The integrity of fuel cladding is ensured by preventing excessive fuel swelling, excessive fuel densification, excessive clad heating, excessive cladding stress and strain. This is achieved by designing the fuel rods so that the following conservative limits are not exceeded during normal operation or any anticipated transient condition (Condition II events):

1. Minimum DNB ratio equal to or greater than the safety analysis limit DNBR.
2. Fuel center temperature below 4700°F.
3. Internal gas pressure (limited to value below that which could cause the diameter-to-gap to increase due to outward clad creep during steady-state operation, and which could cause excessive DNB propagation to occur).
4. Clad stresses less than the Zircaloy or ZIRLOTM yield strength.
5. Clad strain less than 1-percent.

Chapter 3, Page 2 of 94 Revision 25, 2014

IP2 FSAR UPDATE The ability of fuel designed and operated to these criteria to withstand postulated normal and abnormal service conditions is shown by analyses described in Chapter 14 to satisfy the demands of plant operation well within applicable regulatory limits.

The reactor coolant pumps provided for the plant are supplied with sufficient rotational inertia to maintain an adequate flow coastdown and prevent core damage in the event of a simultaneous loss of power to all pumps as discussed in section 14.1.6.1.

In the unlikely event of a turbine trip from full power without an immediate reactor trip, the subsequent reactor coolant temperature increase and volume insurge to the pressurizer result in a high pressurizer pressure trip and thereby prevent fuel damage for this transient. A loss of external electrical load of 50-percent of full power or less is normally controlled by rod cluster insertion together with a controlled steam dump to the condenser to prevent a large temperature and pressure increase in the reactor coolant system and thus prevent a reactor trip. In this case, the overpower-overtemperature protection would guard against any combination of pressure, temperature, and power, which could result in a DNB ratio less than the applicable safety analysis limit DNBR during the transient.

In neither the turbine trip nor the loss-of-flow events do the changes in coolant conditions provoke a nuclear power excursion because of the large system thermal inertia and relatively small void fraction as discussed in UFSAR sections 14.1.8 and 14.1.6, respectively. Protection circuits actuated directly by the coolant conditions identified with core limits are therefore effective in preventing core damage.

3.1.2.2 Suppression of Power Oscillations Criterion: The design of the reactor core with its related controls and protection systems shall ensure that power oscillations, the magnitude of which could cause damage in excess of acceptable fuel damage limits, are not possible or can be readily suppressed. (GDC 7)

The potential for possible spatial oscillations of power distribution for this core has been reviewed. It is concluded that low frequency xenon oscillations may occur in the axial dimension, and the control rods are provided to suppress these oscillations. The core is expected to be stable to xenon oscillations in the X-Y dimension. Ex-core instrumentation is provided to obtain necessary information concerning power distribution. This instrumentation is adequate to enable the operator to monitor and control xenon induced oscillations. (Incore instrumentation is used periodically to calibrate and verify the information provided by the ex-core instrumentation. The analysis, detection, and control of these oscillations is discussed in Reference 1.)

3.1.2.3 Redundancy of Reactivity Control Criterion: Two independent reactivity control systems, preferably of different principles, shall be provided. (GDC 27)

Two independent reactivity control systems are provided, one involving rod cluster control assemblies and the other involving chemical shim.

Chapter 3, Page 3 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.1.2.4 Reactivity Hot Shutdown Capability Criterion: The reactivity control systems provided shall be capable of making and holding the core subcritical from any hot standby or hot operating condition. (GDC 28)

The reactivity control systems provided are capable of making and holding the core subcritical from any hot standby or hot operating condition, including those resulting from power changes.

The maximum excess reactivity expected for the core occurs for the cold, clean condition at the beginning-of-life of the initial core.

The rod cluster control assemblies are divided into control banks and shutdown banks. The control banks used in combination with chemical shim control provide control of the reactivity changes of the core throughout the life of the core during power operation. These banks of rod cluster control assemblies are used to compensate for short term reactivity changes at power that might be produced due to variations in reactor power level or in coolant temperature. The chemical shim control is used to compensate for the more slowly occurring changes in reactivity throughout core life such as those due to fuel depletion and fission product buildup.

3.1.2.5 Reactivity Shutdown Capability Criterion: One of the reactivity control systems provided shall be capable of making the core subcritical under any anticipated operating condition including anticipated operational transients sufficiently fast to prevent exceeding acceptable fuel damage limits. Shutdown margin should assure subcriticality with the most reactive control rod fully withdrawn. (GDC 29)

The reactor core, together with the reactor control and protection system, is designed so that the minimum allowable DNBR is equal to or greater than the applicable safety analysis limit DNBR and there is no fuel melting during normal operation including anticipated transients.

The shutdown banks are provided to supplement the control banks of rod cluster control assemblies to make the reactor at least 1.3-percent subcritical (keff = 0.987) following trip from any credible operating condition assuming the most reactive rod cluster control assembly is in the fully withdrawn position.

Sufficient shutdown capability is also provided so that the minimum DNBR is equal to or greater than the applicable safety analysis limit DNBR, assuming the most reactive rod to be in the fully withdrawn position for the most severe anticipated cooldown transient associated with a single active failure, e.g., accidental opening of a steam bypass, or relief valve, or safety valve stuck open. This is achieved by the combination of control rods and automatic boric acid injection via the emergency core cooling system. The minimum design margin is 1.3-percent throughout core life, as discussed in UFSAR Section 14.2.5.2, assuming the maximum worth control rod is in the fully withdrawn position allowing 10-percent uncertainty in the control rod worth calculations.

Technical Specification 3.1.1 specifies the actual minimum required shutdown margin for core design.

Manually controlled boric acid addition is used to maintain the shutdown margin for the long-term conditions of xenon decay and plant cooldown. Redundant equipment is provided to guarantee the capability of adding boric acid to the reactor coolant system.

Chapter 3, Page 4 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.1.2.6 Reactivity Holddown Capability Criterion: The reactivity control systems provided shall be capable of making the core subcritical under credible accident conditions with appropriate margins for contingencies and limiting any subsequent return to power such that there will be no undue risk to the health and safety of the public. (GDC 30)

Normal reactivity shutdown capability is provided by control rods following a trip signal, with boric acid injection used to compensate for the long-term xenon decay transient and for plant cooldown. As discussed in response to the previous criteria, the shutdown capability maintains the minimum DNBR above the limiting value and prevents exceeding core safety limits as a result of the cooldown associated with a safety valve stuck fully open.

Any time that the reactor is at power, the quantity of boric acid retained in the boric acid tanks and ready for injection always exceeds that quantity required for the normal cold shutdown.

This quantity always exceeds the quantity of boric acid required to bring the reactor to hot shutdown and to compensate for subsequent xenon decay. Boric acid is pumped from the boric acid tanks by one of two boric acid transfer pumps to the suction of one of three charging pumps, which injects boric acid into the reactor coolant. Any charging pump and either boric acid transfer pump can be operated from diesel-generator power on loss of station power.

On the basis of the above, the injection of boric acid is shown to afford backup reactivity shutdown capability, diverse from rod cluster controls, which normally serve this function in the short-term situation. Shutdown for long-term and reduced temperature conditions can be accomplished with boric acid injection using redundant components, thus achieving the measure of reliability implied by the criterion.

Alternately, boric acid solution at lower concentration can be supplied from the refueling water storage tank. This solution can be transferred directly by the charging pumps or alternately by the safety injection pumps. The reduced boric acid concentration lengthens the time required to achieve equivalent shutdown.

3.1.2.7 Reactivity Control Systems Malfunction Criterion: The reactor protection systems shall be capable of protecting against any single malfunction of the reactivity control system, such as unplanned continuous withdrawal (not ejection or dropout of a control rod, by limiting reactivity transients to avoid exceeding acceptable fuel damage limits. (GDC 31)

The reactor protection systems are capable of protecting against any single credible malfunction of the reactivity control system, by limiting reactivity transients to avoid exceeding acceptable fuel damage limits.

Reactor shutdown with rods is completely independent of the normal rod control functions since the trip breakers completely interrupt the power to the rod mechanisms regardless of existing control signals.

Details of the effects of continuous withdrawal of a control rod and continuous deboration are described in Section 14.1 and Section 9.2, respectively.

Chapter 3, Page 5 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.1.2.8 Maximum Reactivity Worth of Control Rods Criterion: Limits, which include reasonable margin, shall be placed on the maximum reactivity worth of control rods or elements and on rates at which reactivity can be increased to ensure that the potential effects of a sudden or large change of reactivity cannot (a) rupture the reactor coolant pressure boundary or (b) disrupt the core, its support structures, or other vessel internals sufficiently to lose capability of cooling the core. (GDC 32)

Limits, which include considerable margin, are placed on the maximum reactivity worth of control rods or elements and on rates at which reactivity can be increased to ensure that the potential effects of a sudden or large change of reactivity cannot (a) rupture the reactor coolant pressure boundary or (b) disrupt the core, its support structures, or other vessel internals so as to lose capability to cool the core.

The reactor control system employs control rod clusters. A portion of these are designated shutdown rods and are fully withdrawn during power operation. The remaining rod clusters comprise the control groups, which are used to control load and reactor coolant temperature.

The rod cluster drive mechanisms are wired into preselected groups, and are therefore prevented from being withdrawn in other than their respective groups. The rod drive mechanism is of the magnetic latch type and the coil actuation is sequenced to provide variable speed rod travel. The maximum reactivity insertion rate is analyzed in the detailed plant analysis assuming two of the highest worth groups to be accidentally withdrawn at maximum speed. This yields a reactivity insertion rate of the order of 70 pcm/sec, which is well within the capability of the overpower-overtemperature protection circuits to prevent core damage.

No single credible mechanical or electrical control system malfunction can cause a rod cluster to be withdrawn at a speed greater than 72 steps per min (approximately 45-in. per min) when the Rod Control System is operating in the MANUAL mode. Single credible electrical system failures can result in withdrawal speeds greater than 72 steps per min during automatic operation. The automatic rod withdrawal feature however, has been permanently defeated at IP2.

3.1.3 Safety Limits The reactor is capable of meeting the performance objectives throughout core life under both operating and malfunction conditions without violating the integrity of the fuel elements. Thus the release of unacceptable amounts of fission products to the coolant is prevented.

The limiting conditions for operation established in the Technical Specifications specify the functional capacity of performance levels permitted to assure safe operation of the facility.

Design parameters, which are pertinent to safety limits are specified below for the nuclear, reactivity control, thermal and hydraulic, and mechanical aspects of the design.

3.1.3.1 Nuclear Limits The nuclear axial peaking factor Fz, and the nuclear enthalpy rise hot channel factor FN H are limited in their combined relationship so as not to exceed the FQ or DNBR limits.

Potential axial xenon oscillations are controlled with control rods to preclude adverse core conditions. The protection system ensures that the nuclear core limits are not exceeded.

Chapter 3, Page 6 of 94 Revision 25, 2014

IP2 FSAR UPDATE For Cycles 13 and beyond, a cycle specific Core Operating Limits Report (COLR) is generated.

Provided in the COLR is the cycle specific Fq and F H limits as well as the limiting K(z) curve (normalized Fq* Power versus core height axial envelope). Also, cycle specific rod insertion limits and axial flux difference band width (delta-I) limits are provided in the COLR. Utilization of the COLR provides maximized operational and/or design flexibility, while adherence to the limits of the COLR and plant Technical Specifications assures that DNB and overpower design limits are met. The expected values for the nuclear heat flux and nuclear enthalpy rise hot channel factors for the current cycle are provided in Table 3.2-1A.

3.1.3.2 Reactivity Control Limits The control system and the operational procedures provide adequate control of the core reactivity and power distribution. The following control limits are met:

1. A minimum hot shutdown margin of 1.3% Keff is available throughout core life assuming a 10-percent uncertainty in the control rod calculation.
2. This shutdown margin is maintained with the most reactive rod cluster control assembly in the fully withdrawn position.
3. The shutdown margin is maintained at ambient temperature by the use of soluble poison.

Technical Specification 3.1.1 specifies the actual minimum required shutdown margin for core design.

3.1.3.3 Thermal and Hydraulic Limits The reactor core is designed to meet the following limiting thermal and hydraulic criteria:

1. The minimum allowable DNBR during normal operation, including anticipated transients, is equal to the applicable safety analysis limit DNBR.
2. Fuel temperature not to exceed 4700F during any anticipated operating condition or anticipated malfunction.

To maintain fuel rod integrity and prevent fission product release, it is necessary to prevent clad overheating under all operating conditions. This is accomplished by preventing a departure from nucleate boiling (DNB), which would cause a large decrease in the heat transfer coefficient between the fuel rods and the reactor coolant, resulting in high clad temperatures.

The ratio of the heat flux causing DNB at a particular core location (as predicted by the WRB-1 correlation) to the existing heat flux at the same core location is the DNB ratio. A DNB ratio of 1.17 for the WRB-1 correlation corresponds to a 95-percent probability at a 95-percent confidence level that DNB does not occur. The DNB ratio for the W-3 correlation is 1.3 for pressure from 1000 to 2300 psia and 1.45 for pressure from 500 to 1000 psia.

3.1.3.4 Mechanical Limits 3.1.3.4.1 Reactor Internals The reactor internal components are designed to withstand the stresses resulting from startup, steady state operation with any number of pumps running, and shutdown conditions. No damage to the reactor internals occurs as a result of loss of pumping power.

Chapter 3, Page 7 of 94 Revision 25, 2014

IP2 FSAR UPDATE Lateral deflection and torsional rotation of the lower end of the core barrel is limited to prevent excessive movements resulting from seismic disturbances and thus prevent interference with rod cluster control assemblies. Core drop in the event of failure of the normal supports is limited so that the rod cluster control assemblies do not disengage from the fuel assembly guide thimbles.

The internals are further designed to maintain their functional integrity in the event of a major loss-of-coolant accident. The dynamic loading resulting from the pressure oscillations because of a loss-of-coolant accident does not cause sufficient deformation to prevent rod cluster control assembly insertion.

3.1.3.4.2 Fuel Assemblies The fuel assemblies are designed to perform satisfactorily throughout their lifetime. The loads, stresses, and strains resulting from the combined effects of flow induced vibrations, earthquakes, reactor pressure, fission gas pressure, fuel growth, thermal strain, and differential expansion during both steady state and transient reactor operating conditions have been considered in the design of the fuel rods and fuel assemblies. The assemblies are also structurally designed to withstand handling and shipping loads prior to irradiation, and to maintain sufficient integrity at the completion of design burnup to permit safe removal from the core, subsequent handling during cooldown, shipment, and fuel reprocessing.

The fuel rods are supported at nine locations along their length within the fuel assemblies by grid assemblies, which are designed to maintain control of the lateral spacing between the rods through the design life of the assemblies. The magnitude of the support loads provided by the grids is established to minimize possible fretting without overstressing the cladding at the points of contact between the grids and fuel rods and without imposing restraints of sufficient magnitude to result in buckling or distortion of the rods. In addition, there are 3 Intermediate Flow Mixing (IFM) grids spaced along the fuel assembly and a protective grid (P-grid) on the bottom of the assembly. These grids do not provide any support function.

The fuel rod cladding is designed to withstand operating pressure loads without rupture and to maintain encapsulation of the fuel throughout the design life.

3.1.3.4.3 Rod Cluster Control Assemblies The criteria used for the design of the cladding on the individual absorber rods in the rod cluster control assemblies are similar to those used for the fuel rod cladding. The cladding is designed to be free standing under all operating conditions and will maintain encapsulation of the absorber material throughout the absorber rod design life. Allowance for wear during operation is included for the rod cluster control assembly cladding thickness.

Adequate clearance is provided between the absorber rods and the guide thimbles, which position the rods within the fuel assemblies so that coolant flow along the length of the absorber rods is sufficient to remove the heat generated without overheating of the absorber cladding.

The clearance is also sufficient to compensate for any misalignment between the absorber rods and guide thimbles and to prevent mechanical interference between the rods and guide thimbles under any operating conditions.

Chapter 3, Page 8 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.1.3.4.4 Control Rod Drive Assembly Each control rod drive assembly is designed as a hermetically sealed unit to prevent leakage of reactor coolant. All pressure-containing components are designed to meet the requirements of the ASME Code,Section III, Nuclear Vessels for Class A vessels.

The control rod drive assemblies for the full length rods provide rod cluster control assembly insertion and withdrawal rates consistent with the required reactivity changes for reactor operational load changes. This rate is based on the worths of the various rod groups, which are established to limit power-peaking flux patterns to design values. The maximum reactivity addition rate is specified to limit the magnitude of a possible nuclear excursion resulting from a control system or operator malfunction. Also, the control rod drive assemblies for the full length rods provide a fast insertion rate during a "trip" of the rod cluster control assemblies, which results in a rapid shutdown of the reactor for conditions that cannot be handled by the reactor control system.

REFERENCES FOR SECTION 3.1

1. Westinghouse Proprietary, "Power Distribution Control in Westinghouse Pressurized Water Reactors," WCAP-7208, 1968.

3.2 REACTOR DESIGN 3.2.1 Nuclear Design And Evaluation This section presents the nuclear characteristics of the core and an evaluation of the characteristics and design parameters, which are significant to design objectives. The capability of the reactor to achieve these objectives while performing safely under normal operational modes, including both transient and steady state, is demonstrated.

3.2.1.1 Nuclear Characteristics of the Design A summary of the reactor nuclear design characteristics is presented in Table 3.2-1 for Cycle 1 and Table 3.2-1A for the current cycle. Some of the presented parameters will change from cycle to cycle depending on reload core designs.

3.2.1.1.1 Reactivity Control Aspects Reactivity control is provided by neutron absorbing control rods and by a soluble chemical neutron absorber (boric acid) in the reactor coolant. The concentration of boric acid is varied as necessary during the life of the core to compensate for:

1. changes in reactivity, which occur with changes in temperature of the reactor coolant from cold shutdown to the hot operating, zero power conditions,
2. changes in reactivity associated with changes in the fission product poisons xenon and samarium,
3. reactivity losses associated with the depletion of fissile inventory and buildup of long-lived fission product poisons (other than xenon and samarium), and
4. changes in reactivity due to burnable poison burnup.

The control rods provide reactivity control for:

Chapter 3, Page 9 of 94 Revision 25, 2014

IP2 FSAR UPDATE

1. fast shutdown,
2. reactivity changes associated with changes in the average coolant temperature above hot zero power (core average coolant temperature is increased with power level),
3. reactivity associated with any void formation, and
4. reactivity changes associated with the power coefficient of reactivity.

3.2.1.1.1.1 Chemical Shim Control Control to render the reactor sub-critical at temperatures below the operating range is provided by a chemical neutron absorber (boron). The boron concentration during refueling following Cycle 1 has been established as shown in Table 3.2-1, line 29. This concentration together with the control rods provides approximately 10-percent shutdown margin for these operations. The concentration is also sufficient to maintain the core shutdown without any rod cluster control rods during refueling. For cold shutdown, at the beginning of core life, a concentration (shown in Table 3.2-1, line 37) is sufficient for 1-percent shutdown with all but the highest worth rod inserted. The boron concentration (Table 3.2-1, line 29) for refueling is equivalent to less than 2-percent by weight boric acid (H3BO3) and is well within solubility limits at ambient temperature.

This concentration is also maintained in the spent fuel pit since it is directly connected with the refueling canal during refueling operations.

The refueling boron concentration requirement for the current cycle is shown in Table 3.2-1A.

For example, the initial Cycle 1 full power boron concentration without equilibrium xenon and samarium was 1186 ppm. As the fission product poisons built up, the boron concentration was reduced to 890 ppm.

This initial boron concentration was that which permitted the withdrawal of the control banks to their operational limits. The Cycle 1 xenon-free, hot zero power shutdown (k = 0.99) with all but the highest worth rod inserted, could be maintained with the boron concentration of 677 ppm.

This concentration is less than the full power operating value with equilibrium xenon.

3.2.1.1.1.2 Control Rod Requirements Neutron-absorbing control rods provide reactivity control to compensate for more rapid variations in reactivity. The rods are divided into two categories according to their function.

Some rods compensate for changes in reactivity due to variations in operating conditions of the reactor such as power or temperature. These rods comprise the control group of rods. The remaining rods, which provide shutdown reactivity, are termed shutdown rods. The total shutdown worth of all the rods is also specified to provide adequate shutdown with the most reactive rod stuck out of the core as discussed in Sections 14.1, 14.2.5, and 14.2.6.

Control rod reactivity requirements at beginning- and end-of-life for Cycle 1 are summarized in Table 3.2-2. The installed worth of the control rods for Cycle 1 is shown in Table 3.2-3. These values will vary from cycle to cycle depending on the reload core design.

The difference is available for excess shutdown upon reactor trip. The control rod requirements are discussed below.

Chapter 3, Page 10 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.1.1.1.3 Total Power Reactivity Defect Control rods must be available to compensate for the reactivity change incurred with a change in power level due to the Doppler effect. The magnitude of this change was determined by measurement during the Cycle 1 Startup test program.

The average temperature of the reactor coolant is increased with power level in the reactor.

Since this change is actually a part of the power dependent reactivity change, along with the Doppler effect and void formation, the associated reactivity change must be controlled by rods.

The largest amount of reactivity that must be controlled is at the end-of-life when the moderator temperature coefficient has its most negative value. The Cycle 1 moderator density coefficient range is given in Table 3.2-1, line 44, while the cumulative reactivity change for Cycle 1 is shown in the first line of Table 3.2-2. By the end of the fuel cycle, the nonuniform axial depletion causes a severe power peak at low power. The reactivity associated with this peak is part of the power defect.

3.2.1.1.1.4 Operational Maneuvering Band The control group is operated at full power within a prescribed band of travel in the core to compensate for periodic changes in boron concentration, temperature, or xenon. The band has been defined as the operational maneuvering band. When the rods reach either limit of the band, a change in boron concentration must be made to compensate for any additional change in reactivity, thus keeping the control group within the maneuvering band.

3.2.1.1.1.5 Control Rod Bite If sufficient boron is present in a chemically shimmed core, the inherent operational control afforded by the negative moderator temperature coefficient is lessened to such a degree that the major control of transients resulting from load variations must be compensated for by control rods. The ability of the plant to accept major load variations is distinct from safety considerations, since the reactor would be tripped and the plant shut down safely if the rods could not follow the imposed load variations. In order to meet required reactivity ramp rates resulting from load changes, the control rods were inserted a given distance into the core. The reactivity worth of this insertion has been defined as control rod bite.

The reactivity insertion rate was sufficient to compensate for reactivity variation due to changes in power and temperature caused either by a ramp load change of 5-percent/min, or by a step load change of 10-percent. An insertion rate of 3 x 10-5 /sec is determined by the transient analysis of the core and plant to be adequate for the most adverse combinations of power and moderator coefficients.

Beginning with Cycle 18, plant operation with Control Bank D at bite position is no longer required. The analyses in support of the stretch power uprate eliminated the need for control rod bite.

3.2.1.1.1.6 Xenon Stability Control Control rods are capable of suppressing xenon-induced power oscillations in the axial direction, should they occur. Ex-core instrumentation is provided to obtain necessary information concerning power distribution. This instrumentation is adequate to enable the operator to monitor and control xenon-induced power oscillations. Extensive analyses, with confirmation of methods by spatial transient experiments at Haddam Neck, have shown that any induced radial Chapter 3, Page 11 of 94 Revision 25, 2014

IP2 FSAR UPDATE or diametral xenon transients would die away naturally. A full discussion of xenon stability control can be found in Reference 1. In assessing potential power distribution instabilities arising from spatial xenon redistribution and in determining stability indices, primary reliance has been placed on time-dependent digital calculations in three dimensions representing feedback reactivity effects by means of semi-empirically fitted expressions whose coefficients were determined from other calculations using standard design analytical techniques and computer codes (e.g., LEOPARD code).

To assess the level of credibility and range of uncertainty attached to xenon stability analyses, conservative values of the reactivity feedback parameters were used to arrive at a reasonable upper limit for the stability index. This technique gives reasonable assurance that the reactor will in fact be stable toward diametral xenon oscillations. Means are available to increase the moderator temperature feedback term in order to stabilize the reactor response to diametral xenon oscillation (Reference 2). The reference three-dimensional time dependent digital calculations have indicated that the Indian Point Unit 2 reactor is stable against diametral xenon transients.

Cross-coupled transients are discussed in Reference 3 on the basis of full three-dimensional analyses of xenon transients.

"Second overtone" xenon transients from quadrant to quadrant (X-Y transient) are also discussed in Reference 3 in the form of radial transients. That is to say that a power-xenon perturbation is introduced by moving the center control rod. "Second overtone" xenon transients from top-to-bottom (axial transient) have been analyzed with results presented in References 1 and 4. For clarity, such transients are presented here specifically for the Indian Point Unit 2 reactor.

Figure 3.2-1 shows a cross-plot of the axial peaking factor and axial offset for transients at three points in core life. This plot is completely in agreement with such plots shown in Reference 1.

In short, the ex-core detector based protection system is capable of detecting (by means of axial offset) transients, which result from perturbations to the "second axial overtone" of the power distribution.

The separation of dimensions is a conceptual artifice, which greatly facilitates analysis of xenon transients. Full three-dimensional transient analyses have been performed, as reported in References 2 and 3. Conclusions relating to power distribution stability against spatial xenon redistribution are based on results of these analyses. Cross-coupling between axial and diametral xenon oscillations are inherently accounted for in the three- dimensional time dependent calculations. Results of these calculations do not reveal any unique problems arising from cross-coupling. See Appendix 3B for additional discussion.

If the core was originally operating with a symmetric quadrant-to-quadrant power distribution, the effect of excess xenon poisoning would be to flatten the power distribution because the xenon excess would be greatest where the equilibrium power has been greatest. While this additional power flattening would tend to decrease the stability of the reactor, the analytical evaluation described in Reference 3 had already assumed a power distribution flatter than expected in the actual reactors; thus, an allowance has already been made in the Reference 3 analysis to account for this effect. Furthermore, the high xenon inventory present under the postulated conditions (i.e., maximum xenon buildup) would decrease the required boron concentration and lead to a more stable reactor response from the enhanced negative moderator reactivity feedback effect.

Chapter 3, Page 12 of 94 Revision 25, 2014

IP2 FSAR UPDATE As burnup progresses, the required boron concentration further decreases resulting in an increasingly more stable reactor response to diametral xenon oscillations. This effect is greater than the effect of burnup on radial power flattening.

If the equilibrium power was not balanced from quadrant to quadrant, the effect of the excess xenon poisoning might be to cause the quadrant power to reverse and perhaps to increase in magnitude. If the quadrant power tilt were to reach the limit given in the Technical Specifications, the operator would take action to maintain core thermal margins.

In any event, the excess xenon, which might be present under the conditions postulated would decay naturally and cannot be regarded as a continuing source of power distribution anomalies.

Similarly, a top-to-bottom power imbalance could be temporarily increased by the excess xenon poisoning. Such an imbalance cannot be a safety problem because the reactor protection system is cognizant of the axial power imbalance and if necessary will reduce trip setpoints accordingly.

3.2.1.1.1.7 Excess Reactivity Insertion Upon Reactor Trip The control requirements are nominally based on providing 1-percent shutdown at hot, zero power conditions with the highest worth rod stuck in its fully withdrawn position or to prevent return to criticality following a credible steamline break, whichever is the more limiting. The condition where excess reactivity insertion is most critical is at the end of a cycle when the steam break accident is considered. For example, the excess control available at the end of Cycle 1, hot zero power condition with the highest worth rod stuck out is 2.08-percent after allowing a 10-percent margin for uncertainty in control rod worth as shown in Table 3.2-3.

3.2.1.1.1.8 Calculated Rod Worths The complement of 53 full length control rods arranged in the pattern shown in Figure 3.2-2 meets the shutdown requirements. Table 3.2-3 lists the calculated worths of this rod configuration for beginning and end of the first cycle.

The calculated reactivity worths listed are decreased in the design by 10-percent to account for any errors or uncertainties in the calculation. This worth is established for the condition that the highest worth rod is stuck in the fully withdrawn position in the core.

A comparison between calculated and measured rod worths in the operating reactor shows the calculation to be well within the allowed uncertainty of 10-percent.

3.2.1.2 Reactor Core Power Distribution The accuracy of power distribution calculations has been confirmed through approximately 1000 flux maps during some 20 years of operation under conditions very similar to those expected for the plant described herein. Details of this confirmation are given in Reference 5.

3.2.1.2.1 Definitions Power distributions are quantified in terms of hot channel factors. These factors are a measure of the peak pellet power within the reactor core and the total energy produced in a coolant channel and are expressed in terms of quantities related to the nuclear or thermal design, namely:

Chapter 3, Page 13 of 94 Revision 25, 2014

IP2 FSAR UPDATE

  • Power density is the thermal power produced per unit volume of the core (kW/liter).
  • Linear power density is the thermal power produced per unit length of active fuel (kW/ft). Since fuel assembly geometry is standardized, this is the unit of power density most commonly used. For all practical purposes it differs from kW/liter by a constant factor, which includes geometry and the fraction of the total thermal power that is generated in the fuel rod.
  • Average linear power density is the total thermal power produced in the fuel rods divided by the total active fuel length of all rods in the core.
  • Local heat flux is the heat flux at the surface of the cladding (BTU-ft-2-hr-1). For nominal rod parameters this differs from linear power density by a constant factor.
  • Rod power or rod integral power is the length integrated linear power density in one rod (kW).
  • Average rod power is the total thermal power produced in the fuel rods divided by the number of fuel rods (assuming all rods have equal length).

The hot channel factors used in the discussion of power distributions in this section are defined as follows:

F Q' Heat Flux Hot Channel Factor, is defined as the maximum local heat flux on the surface of a fuel rod divided by the average fuel rod heat flux, allowing for manufacturing tolerances on fuel pellets and rods.

F NQ ' Nuclear Heat Flux Hot Channel Factor, is defined as the maximum local fuel rod linear power density divided by the average fuel rod linear power density, assuming nominal fuel pellet and rod parameters.

F EQ' Engineering Heat Flux Hot Channel Factor, is the allowance on heat flux required for manufacturing tolerances. The engineering factor allows for local variations in enrichment, pellet density and diameter, surface area of the fuel rod, and eccentricity of the gap between pellet and clad. Combined statistically the net effect is a factor of 1.03 to be applied to fuel rod surface heat flux.

F NH' Nuclear Enthalpy Rise Hot Channel Factor, is defined as the ratio of the integral of linear power along the rod with the highest integrated power to the average rod power.

Manufacturing tolerances, hot channel power distribution and surrounding channel power distributions are treated explicitly in the calculation of the DNBR.

It is convenient for the purposes of discussion to define subfactors of FQ. However, design limits are set in terms of the total peaking factor.

FQ = total peaking factor (or heat flux hot-channel factor)

Chapter 3, Page 14 of 94 Revision 25, 2014

IP2 FSAR UPDATE maximum kW / ft

=

average kW / ft without densification effects FQ = F NQ x F EQ

= F NXY x F NZ x F EQ x F NU where:

F NQ and F EQ are defined above.

F NU = factor for conservatism, assumed to be 1.05 (75% available thimbles)

F NXY = ratio of peak power density to average power density in the horizontal plane of peak local power F NZ = ratio of the power per unit core height in the horizontal plane of peak local power to the average value of power per unit core height. If the plane of peak local power coincides with the plane of maximum power per unit core height, then F NZ is the core average axial peaking factor.

To include the allowance made for densification effects, which are height dependent, the following quantities are defined.

S(Z) = the allowance made for densification effects at height Z in the core.

P(Z) = ratio of the power per unit core height in the horizontal plane at height Z to the average value of power per unit core height.

Then:

maximum kW/ft FQ =

average kW/ft Including densification allowance FQ = max [F NXY (Z) x P(Z) x S(Z) x F NU x F EQ ]

3.2.1.2.2 Radial Power Distributions The power shape in horizontal sections of the core at full power is a function of the fuel and burnable absorber loading patterns, and the presence or absence of a single bank of control rods. Thus, at any time in the cycle, a horizontal section of the core can be characterized as (1) unrodded, or (2) with group D control rods. These two situations combined with burnup effects determine the radial power shapes, which can exist in the core at full power. The effect Chapter 3, Page 15 of 94 Revision 25, 2014

IP2 FSAR UPDATE on radial power shapes of power level, xenon, samarium, and moderator density effects are also considered but these are quite small. The effect of nonuniform flow distribution is negligible. While radial power distributions in various planes of the core are often illustrated, the core radial enthalpy rise distribution as determined by the integral of power up each channel is of greater interest. As an example, Historical Figures 3.2-3 through 3.2-6 show representative radial cycle 1 power distributions for one quarter of the core for representative operating conditions. These conditions are (1) Hot Full Power (HFP) - beginning-of-life (BOL) - unrodded

- no xenon, (2) HFP-BOL - Bank D in - equilibrium xenon - unrodded, (3) HFP - end-of-life (EOL)

- unrodded - equilibrium xenon, (4) HFP, BOL, no xenon, part-length rods in. Figure 3.2-6 is of historical significance only, since part-length rods have been removed.

Since the position of the hot channel varies from time to time a single reference radial design power distribution is selected for DNB calculations. This reference power distribution is chosen conservatively to concentrate power in one area of the core, minimizing the benefits of flow redistribution. Assembly powers are normalized to core average power.

3.2.1.2.3 Axial Power Distributions The shape of the power profile in the axial or vertical direction is largely under the control of the operator through either the manual operation of the control rods or automatic motion of rods responding to manual operation of the soluble boron system. Nuclear effects, which cause variations in the axial power shape include moderator density, Doppler effect on resonance absorption, spatial xenon, and burnup. Automatically controlled variations in total power output and rod motion are also important in determining the axial power shape at any time. Signals are available to the operator from the ex-core ion chambers, which are long ion chambers outside the reactor vessel running parallel to the axis of the core. Separate signals are taken from the top and bottom halves of the chambers. The difference between top and bottom signals from each of four pairs of detectors is displayed on the control panel and called the flux difference, I. Calculations of core average peaking factor for many plants and measurements from operating plants under many operating situations are associated with either I or axial offset in such a way that an upper bound can be placed on the peaking factor. For these correlations axial offset is defined as:

t - b axial offset =

t + b and t and b are the top and bottom detector readings.

3.2.1.2.4 Local Power Peaking Fuel densification, which has been observed to occur under irradiation in several operating reactors, causes the fuel pellets to shrink both axially and radially. The pellet shrinkage combined with random hang-up of fuel pellets results in gaps in the fuel column when the pellets below the hung-up pellet settle in the fuel rod. The gaps vary in length and location in the fuel rod. Because of decreased neutron absorption in the vicinity of the gap, power peaking occurs in the adjacent fuel rods resulting in an increased power peaking factor. A quantitative measure of this local peaking is given by the power spike factor S(Z) where Z is the axial location in the core.

Chapter 3, Page 16 of 94 Revision 25, 2014

IP2 FSAR UPDATE The method used to compute the power spike factor is described in Reference 6. Results reported in Reference 14 show that fuel manufactured by Westinghouse will not densify and therefore no power spike penalty should be included in the safety analysis The power spike factor due to densification is assumed to be a local perturbation applicable to overpower transients. Thus, densification affects FQ but not FNH . The magnitude of the increased power peaking increases from no effect at the bottom of the core to a few percent at the top of the core. For fuel produced by a process other than those for which Reference 6 is applicable, specifications will be followed to ensure that the effects of densification will be no greater than has been allowed for in the design. The specifications for qualifying the extent of densification will be based on the NRC report on fuel densification (Reference 7).

Results reported in a Westinghouse Topical Report concerning the spike penalty in LOCA analysis (Reference 8) show that the power spike penalty does not have to be included in the LOCA envelope.

3.2.1.2.5 Limiting Power Distributions According to the ANS classification of plant conditions, Condition I occurrences are those which are expected frequently or regularly in the course of power operation, maintenance, or maneuvering of the plant. As such, Condition I occurrences are accommodated with margin between any plant parameter and the value of that parameter, which would require either automatic or manual protective action. Inasmuch as Condition I occurrences occur frequently or regularly, they must be considered from the point of view of affecting the consequences of fault conditions (Conditions II, III, and IV). In this regard, analysis of each fault condition described is generally based on a conservative set of initial conditions corresponding to the most adverse set of conditions, which can occur during Condition I operation.

Implicit in the definition of normal operation is proper and timely action by the reactor operator.

That is, the operator follows recommended operating procedures for maintaining appropriate power distributions and takes any necessary remedial actions when alerted to do so by the plant instrumentation. Thus, as stated above, the worst or limiting power distribution, which can occur during normal operation is to be considered as the starting point for analysis of Condition II, III, and IV events.

Improper procedural actions or errors by the operator are assumed in the design as occurrences of moderate frequency (Condition II). Therefore, the limiting power shapes, which result from such Condition II events are those power shapes, which deviate from the normal operating condition at the recommended axial offset band, e.g., due to lack of proper action by the operator during a xenon transient following a change in power level brought about by control rod motion. Power shapes, which fall in this category are used for determination of the reactor protection system setpoints so as to maintain margin to overpower or DNB limits.

The means for maintaining power distributions within the required hot channel factor limits are described in the Technical Specifications. A complete discussion of power distribution control in Westinghouse PWRs is included in Reference 9. Detailed background information on the design constraints on local power density in a Westinghouse PWR, on the defined operating procedures, and on the measures taken to preclude exceeding design limits is presented in the Westinghouse topical report on power distribution control and load following procedures (Reference 4). The following paragraphs summarize these reports and describe the calculations used to establish the upper bound on peaking factors.

Chapter 3, Page 17 of 94 Revision 25, 2014

IP2 FSAR UPDATE The calculations used to establish the upper bound on peaking factors, FQ and F NH , include all of the nuclear effects, which influence the radial and/or axial power distributions throughout core life for various modes of operation including load follow, reduced power operation, and axial xenon transients.

Radial power distributions are calculated for the full power condition and fuel and moderator temperature feedback effects are included for the average enthalpy plane of the reactor. The steady-state nuclear design calculations are done for normal flow with the same mass flow in each channel and flow redistribution effects neglected. The effect of flow redistribution is calculated explicitly where it is important in the DNB analysis of accidents. The effect of xenon on radial power distribution is small but is included as part of the normal design process. Radial power distributions are relatively fixed and easily bounded with upper limits.

The core average axial profile, however, can experience significant changes, which can occur rapidly as a result of rod motion and load changes and more slowly due to xenon distribution.

For the study of points of closest approach to axial power distribution limits, several thousand cases are examined. Since the properties of the nuclear design dictate what axial shapes can occur, boundaries in the limits of interest can be set in terms of the parameters, which are readily observed in the plant. Specifically, the nuclear design parameters, which are significant to the axial power distribution analysis are:

1. Core power level.
2. Core height.
3. Coolant temperature and flow.
4. Coolant temperature program as a function of reactor power.
5. Fuel cycle lifetimes.
6. Rod bank worths.
7. Rod bank overlaps.

Normal operation of the plant assumes compliance with the following conditions:

1. Control rods in a single bank move together with no individual rod insertion differing from the bank demand position by more than the Technical Specification limit.
2. Control banks are sequenced with overlapping banks.
3. The control bank insertion limits are not violated.
4. Axial power distribution procedures, which are given in terms of flux difference control and control bank position, are observed.

The axial power distribution procedures referred to above are part of the required operating procedures, which are followed in normal operation. Briefly they require control of the axial offset (flux difference divided by fractional power) at all power levels within a permissible operating band of a target value corresponding to the equilibrium full power value. In the first cycle, the target value changes from about +10 to percent linearly through the life of the cycle. This minimizes xenon transient effects on the axial power distribution since the procedures essentially keep the xenon distribution in phase with the power distribution.

Calculations are performed for normal operation of the reactor including load following maneuvers. Beginning, middle, and end of cycle conditions are included in the calculations.

Different histories of operation are assumed prior to calculating the effect of load follow transients on the axial power distribution. These different histories assume base loaded operation and extensive load following. For a given plant and fuel cycle, a finite number of Chapter 3, Page 18 of 94 Revision 25, 2014

IP2 FSAR UPDATE maneuvers are studied to determine the general behavior of the local power density as a function of core elevation.

These cases represent many possible reactor states in the life of one fuel cycle, and they have been chosen as sufficiently definitive of the cycle by comparison with much more exhaustive studies performed on some 20 or 30 different, but typical, plant and fuel cycle combinations.

The cases are described in detail in Reference 4, and they are considered to be necessary and sufficient to generate a local power density limit, which, when increased by 5-percent for conservatism, will not be exceeded with a 95-percent confidence level. Many of the points do not approach the limiting envelope. However, they are part of the time histories, which lead to the hundreds of shapes, which do define the envelope. They also serve as a check that the reactor studied is typical of those more exhaustively studied.

Thus, it is not possible to single out any transient or steady-state condition, which defines the most limiting case. It is not even possible to separate out a small number, which form an adequate analysis. The process of generating a myriad of shapes is essential to the philosophy that leads to the required level of confidence. A maneuver, which provides a limiting case for one reactor fuel cycle is not necessarily a limiting case for another reactor or fuel cycle with different control bank worths, enrichments, burnup, coefficients, etc. Each shape depends on the detailed history of operation up to that time and on the manner in which the operator conditioned xenon in the days immediately prior to the time at which the power distribution is calculated.

The calculated points are synthesized from axial calculations combined with radial factors appropriate for rodded and unrodded planes in the first cycle. In these calculations, the effects on the unrodded radial peak of xenon redistribution that occurs following the withdrawal of a control bank (or banks) from a rodded region is obtained from two-dimensional X-Y calculations.

A 1.03 factor to be applied on the unrodded radial peak was obtained from calculations in which xenon distribution was preconditioned by the presence of control rods and then allowed to redistribute for several hours. A detailed discussion of this effect may be found in Reference 4.

The calculated values have been increased by a factor of 1.05 (75% available thimbles) for conservatism and a factor of 1.03 for the engineering factor FEQ.

The envelope drawn over the calculated ([FQ x Power] max) points in Figure 3.2-7 represents an upper bound envelope on local power density versus elevation in the core for Cycles 1 through

12. For Cycles 13 and on, the anticipated normalized FQ times power versus core height limiting K(z) curve is shown in the Unit 2 COLR. It should be emphasized that this envelope is a conservative representation of the bounding values of local power density. Expected values are considerably smaller and, in fact, less conservative bounding values may be justified with additional analysis or surveillance requirements. Additionally, Figure 3.2-7 is based on a radial power distribution invariant with core elevation.

Finally, as previously discussed, this upper bound envelope is based on procedures of load follow, which require operation within an allowed deviation from a target equilibrium value of axial flux difference. [Note - Per Confirmatory Order for Indian Point Unit 2 of February 11, 1980, (letter from W. J. Cahill, Con Edison, to A. Schwencer, NRC), Indian Point Unit 2 is not operated presently in a load follow mode of operation.] These procedures are detailed in the Technical Specifications and are followed by relying only upon ex-core surveillance supplemented by the normal monthly incore core map requirement and by computer based alarms on deviation and time of deviation from the allowed flux difference band.

Chapter 3, Page 19 of 94 Revision 25, 2014

IP2 FSAR UPDATE To determine reactor protection system setpoints with respect to power distributions, three categories of events are considered, namely rod control equipment malfunctions, operator errors of commission and operator errors of omission. In evaluating these three categories of events, the core is assumed to be operating within the four constraints described above.

The first category comprises uncontrolled rod withdrawal (with rods moving in the normal bank sequence). Also included are motions of the banks below their insertion limits, which could be caused, for example, by uncontrolled dilution or primary coolant cooldown. Power distributions are calculated throughout these occurrences assuming short term corrective action, that is, no transient xenon effects are considered to result from the malfunction. The event is assumed to occur from typical normal operating situations, which include normal xenon transients.

It is further assumed in determining the power distributions that total core power level will be limited by reactor trip to below 120-percent. Since the study is to determine protection limits with respect to power and axial off-set, no credit is taken for trip setpoint reduction due to flux difference. The peak power density, which can occur in such events, assuming reactor trip at or below 120-percent, is less than that required for centerline melt, including uncertainties and densification effects.

The second category assumes that the operator malpositions the rod bank in violation of the insertion limits and creates short-term conditions not included in normal operating conditions.

The third category assumes that the operator fails to take action to correct a flux difference violation. The resulting FQ is multiplied by 102-percent power including an allowance for calorimetric error. It should be noted that a reactor overpower accident is not assumed to occur coincident with an independent operator error.

Analysis of possible operating power shapes shows that the appropriate hot channel factors FQ and F NH for peak local power density and for DNB analysis at full power are the values addressed in the Technical Specifications.

FQ can be increased with decreasing power as shown in the Technical Specifications.

Increasing F NH with decreasing power is permitted by the DNB protection setpoints and allows radial power shape changes with rod insertion to the insertion limits. It has been determined that Technical Specifications are met provided that, during normal operation of the plant, there is compliance with the four conditions listed earlier in this section.

When a situation is possible in normal operation, which could result in local power densities in excess of those assumed as the precondition for a subsequent hypothetical accident, but which would not itself cause fuel failure, administrative controls and alarms are provided for returning the core to a safe condition.

3.2.1.2.6 Power Distribution Anomalies A discussion of the means provided to monitor and control power distributions anomalies caused by misplaced control rods and xenon oscillations is given in Appendix 3B.

A description of the protective function in the event of axial xenon oscillations, including calculated peaking factors and DNBRs, and the automatic trip setpoint reduction is given in References 1 and 4. Additional information on the response to ex-core ion chambers, including comparison with experimental information, is given in References 2 and 10. X-Y control rods are Chapter 3, Page 20 of 94 Revision 25, 2014

IP2 FSAR UPDATE not required nor are they employed in the Indian Point Unit 2 reactor. A discussion of the consequences of control rod malposition is given in Appendix 3B and in Reference 2.

No automatic protective function is necessary, since even the complete misalignment of a control rod in the most limiting case (see Reference 2) cannot lead to a DNBR less than the applicable safety analysis limit at operating conditions. Furthermore, (1) rod position indicators are provided, (2) the existence of an asymmetric control rod misalignment would be revealed by the ex-core instrumentation, and (3) both asymmetric and symmetric control rod misalignments can readily be detected by the incore thermocouple system as indicated in References 2 and 10.

3.2.1.2.7 Reactivity Coefficients The response of the reactor core to plant conditions or operator adjustments during normal operation, as well as the response during abnormal or accidental transients, is evaluated by means of a detailed plant simulation. In these calculations, reactivity coefficients are required to couple the response of the core neutron multiplication to the variables, which are set by conditions external to the core. Since the reactivity coefficients change during the life of the core, a range of coefficients is established to determine the response of the plant throughout life and to establish the design of the reactor control and protection system.

3.2.1.2.7.1 Moderator Temperature Coefficient The moderator temperature coefficient in a core controlled by chemical shim is less negative than the coefficient in an equivalent rodded core. One reason is that control rods contribute a negative increment to the coefficient and in a chemical shim core, the rods are only partially inserted. Also, the chemical poison density is decreased with the water density upon an increase in temperature. This gives rise to a positive component of the moderator temperature coefficient due to boron being removed from the core. This is directly proportional to the amount of reactivity controlled by the dissolved poison.

In order to reduce the dissolved poison requirement for control of excess reactivity, burnable absorber rods have been incorporated in the core design. The result is that changes in the coolant density will have less effect on the density of poison and the moderator temperature coefficient will be reduced. The moderator temperature coefficient is negative at the operating coolant temperature with burnable absorber rods installed.

The original burnable absorber was in the form of borated Pyrex glass rods clad in stainless steel. The rods (1412 in the initial core) in the form of clusters were distributed throughout the initial core in vacant rod cluster control guide tubes as illustrated in Figures 3.2-8 and 3.2-9.

Information regarding research, development, and nuclear evaluation of the burnable poison rods can be found in Reference 11. These rods initially controlled 7.2-percent of the installed excess reactivity and their addition resulted in a reduction of the initial hot zero power boron concentration in the coolant to 1318 ppm.

Starting with Cycle 8, the Wet Annular Burnable Absorber (WABA) design has been used. The WABA design is described in Section 3.2.3.2.1.5.

Starting with Cycle 11, the Integral Fuel Burnable Absorber (IFBA) design has also been used.

The IFBA design is described in Section 3.2.3.2.1.5.

Chapter 3, Page 21 of 94 Revision 25, 2014

IP2 FSAR UPDATE The effect of burnup on the moderator temperature coefficient is calculated and the coefficient becomes more negative with increasing burnup. This is due to the buildup of fission products with burnup and dilution of the boric acid concentration with burnup. The reactivity loss due to equilibrium xenon is controlled by boron, and as xenon builds up, boron is taken out. For example, the calculated net effect and the predicted unrodded moderator temperature coefficient equilibrium xenon for Cycle 1 at full power BOL was -0.55 x 10-4/oF. With core burnup, the coefficient became more negative as boron was removed due to the buildup of plutonium and fission products. At Cycle 1 end-of-life with no boron or rods in the core, the moderator coefficient was -3.0 x 10-4/oF.

Variation in moderator temperature can be seen, for example, from the Cycle 1 Figures 3.2-10 through 3.2-12.

3.2.1.2.7.2 Moderator Pressure Coefficient The moderator pressure coefficient has an opposite sign to the moderator temperature coefficient. Its effect on core reactivity and stability is small because of the small magnitude of the pressure coefficient, a change of 50 psi in pressure having no more effect on reactivity than a one-half degree change in moderator temperature. The calculated Cycle 1 beginning and end-of-life pressure coefficients are specified in Table 3.2-1, line 43.

3.2.1.2.7.3 Moderator Density Coefficient A uniform moderator density coefficient is defined as a change in the neutron multiplication per unit change in moderator density. The range of the moderator density coefficient for Cycle 1, for example, from BOL and EOL is specified in Table 3.2-1.

3.2.1.2.7.4 Doppler and Power Coefficients The Doppler coefficient is defined as the change in neutron multiplication [Note - Neutron multiplication is defined as the ratio of the average number of neutrons produced by fission in each generation to the total number of corresponding neutrons absorbed.] per degree change in fuel temperature. The coefficient is obtained by calculating neutron multiplication as a function of effective fuel temperature. As an example, the Cycle 1 results, using the LEOPARD code (Reference 12), are shown in Figure 3.2-13.

In order to know the change in reactivity with power, it is necessary to know the change in the effective fuel temperature with power as well as the Doppler coefficient. It is very difficult to predict the effective temperature of the fuel using a conventional heat transfer model because of uncertainties in predicting the behavior of the fuel pellets. Therefore, an empirical approach is taken to calculate the power coefficient, based on operating experience of existing Westinghouse cores. As an example, Figure 3.2-14 shows the power coefficient as a function of power for Cycle 1 obtained by this method. The results presented do not include any moderator coefficient even though the moderator temperature changes with power level.

As the fuel pellet temperature increases with power, the resonance absorption in U-238 increases due to Doppler broadening of the resonances. A large temperature drop occurs across the fuel pellet-clad gap. Under certain conditions, this gap may be closed, thus resulting in lower pellet temperature. The net effect is a lower effective fuel temperature, a higher (more negative) Doppler coefficient, and a lower (less negative) power coefficient than that which exists with a pellet-clad gap. For example, the power coefficient for Cycle 1, which was determined using a closed gap model, is shown in Figure 3.2-15.

Chapter 3, Page 22 of 94 Revision 25, 2014

IP2 FSAR UPDATE Calculations indicate the stability of the reactor to xenon oscillations is relatively insensitive to the thermal model used to obtain the power coefficient. The damping factor associated with the fuel Doppler effect is:

Keff T f = x T P where:

T = fuel temperature P = power T

The quantity is larger for the gap model than for the no gap case but since the Doppler P

coefficient varies as T -1/2 the term Keff is smaller.

T The net effect is that f is relatively insensitive to the thermal model in the range of power 0.5 to 1.5 of core average, which is the range of interest for stability.

3.2.1.3 Nuclear Evaluation of Current Core Three principal computer codes have been used in the nuclear design on this reload cycle.

These are: PARAGON (two-dimensional), ANC (two-dimensional and three-dimensional) and APOLLO (one-dimensional). Descriptions and uses for these codes are given below:

PARAGON is a two dimensional, multi-group transport theory code which utilizes a 70 energy-group cross section library. It provides the capability for cell lattice modeling on an assembly level. In this design, PARAGON is used to provide homogenized, two-group cross sections for nodal calculations and feedback models. Also, PARAGON is used to generate appropriately weighted constants for the baffle/reflector regions.

ANC is an advanced nodal code capable of two-dimensional and three-dimensional calculations. In this design, ANC is employed as the reference model for all safety analysis calculations, power distributions, peaking factors, critical boron concentrations, control rod worth, reactivity coefficients, etc. In addition, 3D ANC is used to validate one and two-dimensional results and to provide information about radial (x-y) peaking factors as a function of axial position. It has the capability of calculating discrete pin powers from the nodal information as well.

APOLLO, an advanced version of PANDA, is a two group, one-dimensional diffusion-depletion code. It uses cross sections generated by a radial averaging of the corresponding 3D model cross sections and is used as a one-dimensional axial model. Thermal feedback is included in the calculational models. The axial model is used for computing axial power distributions, differential rod worths, control rod operating limits (insertion limits, return to power limits), etc.

Additional support codes are used for special calculations such as determining fuel temperatures.

Chapter 3, Page 23 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.2 Thermal and Hydraulic Design and Evaluation

[Note - A large amount of material has been retained as historical background.]

3.2.2.1 Thermal and Hydraulic Characteristics of the Design 3.2.2.1.1 Central Temperature of the Hot Pellet The temperature distribution in the pellet is mainly a function of the uranium-dioxide thermal conductivity and the local power density. The absolute value of the temperature distribution is affected by the cladding temperature and the thermal conductance of the gap between the pellet and the cladding.

The gap conductance model is selected such that when combined with the UO2 thermal conductivity model, the calculated fuel centerline temperatures reflect the inpile temperature measurements. A more detailed discussion of the gap conductance model has been provided in References 83 and 84. The temperature drop across the gap is calculated by assuming an annular gap conductance model of the following form:

K gas h=

+r 2

where:

h = contact conductance, Btu/hr-ft2-oF Kgas = thermal conductivity of the gas mixture including a correction factor (Reference 25) for the accommodation coefficient for light gases, e.g., helium, Btu/hr-ft-°F

= diametral gap size, ft r = effective gap spacing due to surface roughness, ft or an empirical correlation derived from thermocouple and melt radius data.

The larger gap conductance value from the equation above and the empirical correlation is used to calculate the temperature drop across the gap for finite gaps.

For evaluations in which the pellet-clad gap is closed, a contact conductance is calculated. The contact conductance between UO2 and zircaloy has been measured and found to be dependent on the contact pressure, composition of the gas at the interface, and the surface roughness (References 25 and 26). This information, together with the surface roughness found in Westinghouse fuel, leads to the following correlation:

Kgas h = 0.6P +

r r = effective gap spacing due to surface roughness, ft h = contact conductance, Btu/hr-ft2-oF P = contact pressure, psi Kgas = thermal conductivity of gas mixture at the interface including a correction factor (Reference 25) for the accommodation coefficient for light gases, e.g., helium, Btu/hr-ft-°F Chapter 3, Page 24 of 94 Revision 25, 2014

IP2 FSAR UPDATE The thermal conductivity of uranium-dioxide was evaluated from data reported by Howard, et al.,27 Lucks, et al.,28 Daniel, et al.,29 Feith,30 Vogt, et al.,31 Nishijima, et al.,32 Ainscough, et al.,33 Godfrey, et al.,34 Stora, et al.,35 Bush,36 Asamoto, et al.,37 Kruger,38 and Gyllander.39 At the higher temperatures, thermal conductivity is best obtained by utilizing the integral conductivity to melt, which can be determined with more certainty. From an examination of the 2800°C data, it has been concluded that the best estimate for the value of Kdt is 93 watts/cm. This 0

conclusion is based on the integral values reported by Gyllander,39 Lyons, et al.,40 Duncan,41 Bain,42 and Stora.43 The design curve for the thermal conductivity is shown in Figure 3.2-38. The section of the curve at temperatures between 0oC and 1300oC is in excellent agreement with the recommendation of the IAEA panel.44 The section of the curve above 1300oC is derived for an integral value of 93 watts/cm.39,41,43 Thermal conductivity for UO2 at 95-percent theoretical density can be represented best by the following equation:

1 K = + 8.775 x 10-13 T 3 11.8 + 0.0238T where:

K = watt/cm°C T = °C Based upon the above considerations, the maximum central temperature of the hot pellet at steady state is shown in Table 3.2-6. This temperature is well below the melting temperatures of the irradiated UO2, which is taken as 5080oF (Reference 45) unirradiated and decreasing by 58oF per 10,000 MWd/metric ton uranium.

Westinghouse experience with fuel rods operating at high power ratings has been summarized in Appendix A, Indian Point No. 2 Preliminary Safety Analysis Report (Docket 50-247) and in Appendix-Section IX of the Preliminary Safeguards Report for the Saxton Reactor Operating at 35 MWt (Docket 50-146). These reports presented considerable statistical evidence of successful operation of high performance zircaloy clad fuel rods in CVTR (1368 rods) and Shipping port core I Blanket (94,920 rods). Since the date of these reports, a significant amount of additional information has been developed relating to the integrity of free standing zircaloy-clad oxide fuel rods at high power ratings. In addition, a comprehensive experimental program was initiated to extend the operating experience to higher power and to higher exposures for many of these fuel rods. This information is summarized in Figure 3.2-39.

More detailed information about Westinghouse experience with high power fuel rod bars has been provided in Reference 46.

3.2.2.1.2 Heat Flux Ratio and Data Correlation Departure from Nucleate Boiling (DNB) is predicated upon a combination of hydrodynamic and heat transfer phenomena and is affected by the local and upstream conditions including the flux Chapter 3, Page 25 of 94 Revision 25, 2014

IP2 FSAR UPDATE distribution. In reactor design, the heat flux associated with DNB and the location of DNB are both important. The W-3 based L-grid DNB correlation was used in design of the LOPAR fuel assemblies. The WRB-1 DNB correlation, Reference 76, is the primary DNB correlation for the analysis of the optimized and VANTAGE+ fuel assemblies. The W-3 DNB correlation47 was developed to predict the DNB flux and the location of DNB equally well for uniform and an axially nonuniform heat flux distribution. This correlation replaced the WAPD q" and H DNB correlations published in Nucleonics,48 May 1963, in order to eliminate the discontinuity of the latter at the saturation temperature and to provide a single unambiguous criterion of the design margin.

The W-3 correlation, and several modifications of it, have been used in Westinghouse critical heat flux (CHF) calculations. The W-3 correlation was originally developed from single tube data,49 but was subsequently modified to apply to the "L" grid50 rod bundle data. These modifications to the W-3 correlation have been demonstrated to be adequate for reactor rod bundle design.

The W-3 DNB correlation47 incorporates both local and system parameters in predicting the local DNB heat flux. This correlation includes the nonuniform flux effect and the upstream effect, which includes inlet enthalpy or length. The local DNB heat flux ratio (defined as the ratio of the DNB heat flux to the local heat flux) is indicative of the contingency available in the local heat flux without reaching DNB.

The sources of the data used in developing the correlation were:

WAPD-188 (1958) CU-TR-No. l (NW-208) (1964)

ASME Paper 62-WA-297 (1962) CISE-R-90 (1964)

CISE-R-63 (1962) DP-895 (1964)

ANL-6675 (1962) AEEW-R-356 (1964)

GEAP-3766 (1962) BAW-3238-7 (1965)

AEEW-R-213 and 309 (1963) AE-RTL-778 (1965)

CISE-R-74 (1963) AEEW-355 (1965)

CU-MPR-XIII (1963) EUR-2490.e (1965)

The comparison of the W-3 measured to predicted DNB flux of this correlation is given in Figure 3.2-40. The local flux DNB ratio versus the probability of not reaching DNB is plotted in Figure 3.2-41. This plot indicates that with a DNBR of 1.3 the probability of not reaching DNB is 95-percent at a 95-percent confidence level. The comparison of the "L"-grid measured to predicted DNB flux is given in Figure 3.2-42.

Rod bundle data without mixing vanes agree very well with the predicted DNB flux as shown in Figure 3.2-43. Rod bundle data with mixing vanes (Figure 3.2-44) show on the average an 8-percent higher value of DNB heat flux than predicted by the W-3 DNB correlation. The L-grid modified spacer factor has been formulated to reflect the improvement in DNB heat flux due to the presence of mixing vanes.

It should be emphasized that the inlet subcooling effect of the W-3 correlation was obtained from both uniform and non-uniform data. The existence of an inlet subcooling effect has been demonstrated to be real and hence the actual subcooling should be used in the calculations.

The W-3 correlation was developed from tests with flow in tubes and rectangular channels.

Good agreement was obtained when the correlation is applied to test data for rod bundles.

Chapter 3, Page 26 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.2.1.3 Definition of Departure From Nucleate Boiling Ratio The DNB heat flux ratio (DNBR) as applied to the design when all flow cell walls are heated is:

q" DNB,N x F 'S x 0.986 DNBR = (for LOPAR Fuel) q" loc The DNB heat flux ratio (DNBR) as applied to typical cells (flow cells with all walls heated) and thimble cells (flow cells with heated and unheated walls) is defined as:

q"DNB,N DNBR=

q"loc where:

q" DNB,EU q" DNB,N =

F and q"DNB,EU is the uniform DNB heat flux as predicted by the WRB-1 DNB Correlation and the W-3 DNB correlation (Reference 47) when all flow cells are heated. The flux shape factor to account for nonuniform axial heat flux distributions is F (Reference 47) with the "C" term modified as in Reference 49.

Fs is the modified spacer factor, which uses an axial grid spacing coefficient, KS, and a thermal diffusion coefficient, TDC, based on the 20-in. grid spacing data.

q"loc is the actual local heat flux.

The DNBR as applied to the W-3 DNB correlation when a cold wall is present is:

q" DNB, N, CW DNBR =

q"loc where:

q"DNB, EU,Dh x CWF q"DNB, N, CW =

F q"DNB,EU,Dh is the uniform DNB heat flux as predicted by the W-3 cold wall DNB correlation (Reference 49) when not all flow cell walls are heated (thimble cold wall cell).

W-3 Cold Wall Factor:

q" coldwall G -0.0535 CWF= =1.0- R u {13.76 1.372e 1.78

-4.732( )

q" w 3,Dh 10 6 P 0.14

- 0.0619( ) - 8.509 Dh0.107]

1000 where:

Ru = (Dh - De / Dh), q"W - 3, Dh = prediction of W - 3 correlation using Dh for De Chapter 3, Page 27 of 94 Revision 25, 2014

IP2 FSAR UPDATE The equivalent uniform DNB flux q'DNB,EU is calculated for the W-3 equivalent uniform flux DNB correlation as follows:

q"DNB,EU 6

[

= (2.022 - 0.0004302p ) + (0.1722 - 0.0000984p ) e(18.177-0.004129) ]

10 G

x 1.037 + 6 (0.1484 - 1.596 + 0.1729 ) x [ 1.157 - 0.869]

10 x[0.2664 + 0.8357e-3.151De] x [0.8258 + 0.000794 ( H sat - H in )]

The heat flux is in Btu/hr-ft2 and the units of the parameters are as listed below. The ranges of parameters for applicability of the W-3 DNB correlation are:

System pressure, p = 500 to 2400 psia Mass velocity, G = 1.0 x 106 to 5.0 x 106 lb/hr ft2 Equivalent diameter, De = 0.2 to 0.7-in.

Quality, loc = -0.15 to +0.15 Inlet enthalpy, no limit, Btu/lb Length, L = 10 to 168-in.

Heated perimeter

= 0.88 to 1.00 Wetted perimeter Geometries - circular tubes and rectangular channels Flux = Uniform and non-uniform heat flux converted from non-uniform data by using F-factor of Reference 47.

For the LOPAR fuel, which uses the "L"-grid modified W-3 DNB correlation with the modified spacer factor (Reference 50):

.5 G TDC .35 F S = (1.445 -.0371L)

P 225.896

( e ( + .2 )2

)

-.73 + K S 10 6 .019 Where: KS = spacer factor dependent on grid type and axial spacing P = inlet pressure, psia G = inlet mass velocity, lbm/hr-ft2 TDC = thermal diffusion coefficient L = test length, ft

= local quality, fraction The ranges of the parameters listed above are:

1460 < P < 2430 psia 1.96 x 106 < G < 3.68 x 106 lbm/hr-ft2

-0.15 < < +0.15 fraction Chapter 3, Page 28 of 94 Revision 25, 2014

IP2 FSAR UPDATE 8 < L < 14-ft Geometries ("L"-grid correlation) - circular tubes and rectangular channels Flux = Various nonuniform heat fluxes Local Nonuniform DNB Flux The local nonuniform q"DNB,N is calculated as follows:

q"DNB,EU q"DNB,N =

F where:

DNB C C

q(z )e DNB Z F= C DNB dz at DNB x(1 e qlocal ) 0 DNB = distance from the inception of local boiling to the point of DNB, in inches.

Z = distance from the inception of local boiling measured in the direction of flow, in inches.

4.31 (1 - DNB) -1 C = 0.15 in. (Reference 49) 6 0.478 (G/ 10 )

Where:

G = mass velocity, lb/hr-ft2 DNB = quality of the coolant at the location where DNB flux is calculated In determining the F-factor, the value of q"local at DNB in the above equation for the F-factor was measured as z = DNB, the location where the DNB flux is calculated. For a uniform flux, F becomes unity so that q"DNB,N reduces to q"DNB,EU as expected. The criterion for determining the predicted location of DNB is to evaluate the ratio of the predicted DNB flux to the local heat flux along the length of the channel. The location of the minimum DNB ratio is considered to be location of DNB.

3.2.2.1.4 Procedure for Using W-3 L-grid Correlation In predicting the local DNB flux in a nonuniform heat flux channel, the following two steps are required:

1. The uniform DNB heat flux, q"DNB,EU, is computed with the W-3 L-grid correlation using the specified local reactor conditions.
2. This equivalent uniform heat flux is converted into corresponding nonuniform DNB heat flux, q"DNB,N, for the nonuniform flux distribution in the reactor. This is Chapter 3, Page 29 of 94 Revision 25, 2014

IP2 FSAR UPDATE accomplished by dividing the uniform DNB flux by the F-factor.47 Since F is generally greater than unity, q"DNB,N will be smaller than q"DNB,EU.

To calculate the DNBR of a reactor channel, the values of q" DNB,N q" loc along the channel are evaluated and the minimum value is selected as the minimum DNBR incurred in that channel.

The W-3 L-grid correlation depends on both local and inlet enthalpies of the actual system fluid, and the upstream conditions are accommodated by the F-factor. Hence, the correlation provides a realistic evaluation of the safety margin on heat flux.

3.2.2.1.5 The WRB-1 DNB Correlation The WRB-176 correlation was developed based exclusively on the large bank of mixing vane grid rod bundle critical heat flux data (in excess of 1100 points) that Westinghouse has collected. The WRB-1 correlation, based on local fluid conditions, represents the rod bundle data with better accuracy over a wide range of variables than the previous correlation used in design (namely the W-3 correlation). This correlation accounts directly for both typical and thimble cold wall cell effects, uniform and non-uniform heat flux profiles, and variations in rod heated length and in grid spacing.

The applicable range of variables is:

Pressure 1440 < P < 2490 psia Local Mass Velocity 0.9 < Gloc/106 < 3.7 lb/ft2-hr Local Quality -0.2 < loc < 0.3 Heated Length, Inlet to CHF Location Lh < 14 feet Grid Spacing 13 < gsp < 32 inches Equivalent Hydraulic Diameter 0.37 < de < 0.60 inches Equivalent Heated Hydraulic Diameter 0.46 < dh < 0.68 inches Figure 3.2-44A shows measured critical heat flux plotted against predicted critical heat flux using the WRB-1 correlation.

A correlation limit DNBR of 1.17 for the WRB-1 correlation has been approved by the NRC for the 15x15 fuel.

3.2.2.1.6 The W-3 DNB Correlation The W-3 DNB correlation47, 49 and 95 is used for both fuel types where the primary DNB correlation is not applicable. The WRB-1 correlation is developed based on mixing vane data and therefore is only applicable in the heated rod spans above the first mixing vane grid. The W-3 correlation, which does not take credit for mixing vane grids, is used to calculate DNBR values in the heated region below the first mixing vane grid. In addition, the W-3 correlation is applied in the analysis of accident conditions where the system pressure is below the range of the primary correlation.

For system pressure in the range of 500 to 1000 psia, the W-3 correlation is 1.45 89. For system pressure greater that 1000 psia, the W-3 correlation is limited to 1.30. A cold wall factor50 is applied to the W-3 DNB correlation to account for the pressure of the unheated thermal surface.

Chapter 3, Page 30 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.2.1.7 Film Boiling Heat Transfer Coefficient Heat transfer after departure from nucleate boiling was conservatively assumed to be limited by film boiling immediately, and the period of transition boiling neglected.

The correlation used to evaluate these film boiling heat transfer coefficients was developed by Tong, Sandberg and Bishop51 and is shown in Figure 3.2-45.

0.80 1.23 0.68 0.068 hD DG Cp g g

= 0.0193 k f f k f b where: b = g + (l - ) and CP = heat capacity at constant pressure, Btu/lb-oF D = equivalent diameter of flow channel, ft h = heat transfer coefficient, Btu/hr-ft2-oF G = mass flow rate, lb/hr-ft2 k = thermal conductivity, Btu/hr-ft-oF

= void fraction

= density, lbs/ft3

= viscosity, lbs/ft-hr Subscripts:

g = Evaluation of the property at the saturated vapor condition

= Evaluation of the property at the saturated liquid condition f = Evaluation of the property at the average film temperature w = Evaluation of the property at the wall temperature b = Evaluation of the property at the average bulk fluid condition The heat transfer correlation was developed for flow rates equal or greater than 0.8 x 106 lb/hr ft2 over a pressure range of 580 to 3190 psia, for qualities as high as 100-percent, and heat flux from 0.1 to 0.65 x 106 Btu/hr ft2.

3.2.2.2 Hot Channel Factors The total hot channel factors for heat flux and enthalpy rise are defined as the maximum-to-core average ratios of these quantities. The heat flux factor considers the local maximum linear heat generation rate at a point (the "hot spot"); the enthalpy rise hot channel factor involves the maximum integrated value along a channel (the "hot channel").

3.2.2.2.1 Definition of Engineering Hot Channel Factor Each of the total hot channel factors is composed of a nuclear hot channel factor describing the neutron flux distribution and an engineering hot channel factor, which allows for variations in flow conditions and fabrication tolerances. The engineering hot channel factors are made up of subfactors, which account for the influence of the variations of fuel pellet diameter, density, enrichment and eccentricity; fuel rod diameter; inlet flow distribution; flow redistribution; and flow mixing.

Chapter 3, Page 31 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.2.2.2 Heat Flux Engineering Subfactor, F EQ The heat flux engineering hot channel factor is used to evaluate the maximum linear heat generation rate in the core. This subfactor is determined by statistically combining the fabrication variations for fuel pellet diameter, density, enrichment and variation in fuel rod diameter, and has a value of 1.03 to be applied to the fuel rod surface heat flux. As shown in Reference 52, no DNB penalty need be taken for the short relatively low intensity heat flux spikes caused by variations in the above parameters or fuel pellet eccentricity 3.2.2.2.3 Enthalpy Rise Engineering Subfactor, F EH The effect of variations in flow conditions and fabrication tolerances on the hot channel enthalpy rise in reload analysis is directly considered in the Westinghouse version of VIPRE-01 Code 100,101 thermal subchannel analysis under any reactor operating condition (refer to Section 3.2.2.4, DNB Analysis Method for VIPRE description). The items presently considered contributing to the enthalpy rise engineering hot channel factor are discussed below:

1. Pellet diameter, density and enrichment Variation in pellet diameter, density and enrichment are considered, statistically, in establishing the limit DNBR's (see section 3.2.2.4) for the Revised Thermal Design Procedure97 employed in this application. Uncertainties in the variables are determined from sampling of manufacturing data.
2. Inlet Flow Maldistribution Data have been considered from several one-seventh scale hydraulic reactor model tests (References 53, 54, and 55) in arriving at the core inlet flow maldistribution criteria to be used in the THINC56 analyses. THINC analyses made, using these data, have indicated that a conservative design basis is to consider a 5-percent reduction in the flow to the hot assembly (Reference 78).

The design basis of 5% flow reduction to the hot assembly is also used in the VIPRE analysis for the 1.4% power uprate.

3. Flow Redistribution The flow redistribution accounts for the reduction in flow in the hot channel resulting from the high flow resistance in the channel due to the local or bulk boiling. The effect of the nonuniform power distribution is inherently considered in the VIPRE analysis for every operating condition, which is evaluated.
4. Flow Mixing The mixing vanes incorporated in the spacer grid design induce additional flow mixing between the various flow channels in a fuel assembly as well as between adjacent assemblies. This mixing reduces the enthalpy rise in the hot channel resulting from local power peaking or unfavorable mechanical tolerances. The subchannel mixing model now incorporated in the VIPRE code and used in reload reactor design is based on experimental data (Reference 57).

Chapter 3, Page 32 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.2.3 Core Pressure Drop and Hydraulic Loads Core and vessel pressure losses are calculated by equations of the form:

L V2 PL = K + F 2 (144)

D e gc where:

PL = unrecoverable pressure drop, lbf/in.2

= fluid density, lbm/ft3 L = length, ft De = equivalent diameter, ft V = fluid velocity, ft/sec gc = 32.174, lbm-ft/lbf-sec2 K = form loss coefficient, dimensionless F = friction loss coefficient, dimensionless Fluid density is assumed to be constant at the appropriate value for each component in the core and vessel. Because of the complex core and vessel flow geometry, precise analytical values for the form and friction loss coefficients are not available. Therefore, experimental values for these coefficients are obtained from geometrically similar models.

The results of full scale tests of core components and fuel assemblies are utilized in developing the core pressure loss characteristic in reload reactor design. The pressure drop for the vessel has been obtained by combining the core loss with correlation of one-seventh scale model hydraulic test data on a number of vessels (References 53 and 54) and form loss relationships (Reference 58). Moody (Reference 59) curves have been used to obtain the single phase friction factors.

The fuel assembly hold-down springs are designed to keep the fuel assemblies in contact with the lower core plate under all Condition I and II events, with the exception of the turbine overspeed transient associated with a loss of external load. The hold-down springs are designed to tolerate the possibility of an over deflection associated with fuel assembly liftoff for this case and provide contact between this transient. More adverse flow conditions occur during a loss-of-coolant accident. Hydraulic loads at normal operating conditions are calculated considering the best estimate flow and accounting for the minimum core bypass flow based on manufacturing tolerances. Core hydraulic loads at cold plant startup conditions are based on the best estimate flow, but are adjusted to account for the coolant density difference.

Conservative core hydraulic loads for a pump overspeed transient, which could possibly create flow rates 20-percent greater than the best estimate flow, are evaluated to be approximately twice the fuel assembly weight. The hydraulic forces are not sufficient to lift a rod control cluster during normal operation even if the rod cluster is detached from its coupling.

3.2.2.4 Thermal and Hydraulic Design Parameters The thermal and hydraulic design parameters are given in Table 3.2-6, Sheets 1-3.

Sheet 3 shows parameters over a range of vessel average temperatures, giving flexibility to operate at full licensed power at various plant operating conditions.

Chapter 3, Page 33 of 94 Revision 25, 2014

IP2 FSAR UPDATE DNB Design Basis There will be at least a 95-percent probability that departure from nucleate boiling (DNB) will not occur on the limiting fuel rods during normal operation and operational transients and any transient conditions arising from faults of moderate frequency (Condition I and II events), at a 95-percent confidence level. Historically, this has been conservatively met by adhering to the following thermal design basis: there must be at least a 95-percent probability that the minimum departure from nucleate boiling ratio (DNBR) of the limiting power rod during Condition I and II events is greater than or equal to the DNBR limit of the DNB correlation being used. The DNBR limit for the correlation is established based on the variance of the correlation such that there is a 95-percent probability with 95-percent confidence that DNB will not occur when the calculated DNBR is at the DNBR limit.

DNB Analysis Method The THINC IV 77, 78 computer program, beginning in Cycle 10, was used to perform the thermal/hydraulic calculations for both fuel types. The THINC IV code is used to calculate coolant density, mass velocity, enthalpy, void fractions, static pressure and DNBR distributions along flow channels within a reactor core under all expected operating conditions. References 77 and 78 contain details of the THINC IV computer program, including models and correlations used. The Westinghouse version of the VIPRE-01 (VIPRE) code is used. The VIPRE code is equivalent to the THIC-VI (THINC) code and has been approved by the NRC for licensing applications to replace the THINC code. The use of VIPRE is in full compliance with the conditions specified in the NRC Safety Evaluation Report (SER) on WCAP-14565-P-A (Reference 101). The design method employed for both fuel types to meet the DNB design basis is the Revised Thermal Design Procedure.97 Uncertainties in plant operating parameters, nuclear and thermal parameters, and fuel fabrication parameters are considered statistically such that there is at least a 95-percent probability that the minimum DNBR will be greater than or equal to the limit DNBR for the limiting power rod. Plant parameter uncertainties are used to determine the plant DNBR uncertainty. The DNBR uncertainty, combined with the DNBR limit, establishes a design DNBR value, which must be met in plant safety analyses. Since the parameter uncertainties are considered in determining the design DNBR value, the plant safety analyses are performed using values of input parameters without uncertainties. In addition, the limit DNBR values are increased to values designated as the safety analysis limit DNBR's. The plant allowances available between the safety analysis limit DNBR values and the design limit DNBR values is not required to meet the design basis. This allowance will be used for flexibility in the design and operation of this plant.

For this design, the WRB-1 correlation is used for analysis of the Vantage+ fuel assemblies with a correlation limit of 1.17 (both typical and thimble cells).

The design method employed for both fuel types to meet the DNB design basis is the Revised Thermal Design Procedure (RTDP)97. With the RTDP methodology, uncertainties in plant operating parameters, nuclear and thermal parameters, fuel fabrication parameters, computer codes and DNB correlation predictions are considered statistically to obtain DNB uncertainty factors. Based on the DNB uncertainty factors, RTDP design limit DNBR values are determined such that there is at least a 95% probability at a 95% confidence level that DNB will not occur on the most limiting fuel rod during normal operation and operational transients and during transient conditions arising from faults of moderate frequency (Condition I and II events as defined in ANSI N18.2)

Chapter 3, Page 34 of 94 Revision 25, 2014

IP2 FSAR UPDATE To maintain DNBR margin to offset DNB penalties such as those due to fuel rod bow (see section 3.2.2.6) and potential transition core (see 3.2.2.5.1), the safety analyses were performed to DNBR limits higher than the design limit DNBR values. The difference between the design limit DNBRs and the safety analysis limit DNBRs results in available DNBR margin.

The net DNBR margin, after consideration of all penalties, is available for operating and design flexibility. The Standard Thermal Design Procedure (STDP) is used for those analyses where RTDP is not applicable. In the STDP method the parameters used in analysis are treated in a conservative way from a DNBR standpoint. The parameter uncertainties are applied directly to the plant safety input values to give the lowest minimum DNBR. The DNBR limit for STDP is the appropriate DNB correlation limit increased by sufficient margin to offset the applicable DNBR penalties.

For this design, the WRB-1 correlation is used for analysis of both fuel types with a correlation limit of 1.17 (both typical and thimble cells). When the core condition is outside the range of the WRB-1 correlation, the W-3 correlation is applied with a correlation limit of 1.30 (both cell types).

DNB With Physical Burnout Westinghouse60 has conducted DNB tests in a 25-rod bundle where physical burnout occurred with one rod. After this occurrence, the 25-rod test section was used for several days to obtain more DNB data from the other rods in the bundle. The burnout and deformation of the rod did not affect the performance of neighboring rods in the test section during the burnout or the validity of the subsequent DNB data points as predicted by the W-3 correlation. No occurrences of flow instability or other abnormal operations were observed.

DNB With Return to Nucleate Boiling Additional DNB tests have been conducted by Westinghouse61 in 19 and 21 rod bundles. In these tests, DNB without physical burnout was experienced more than once on single rods in the bundles for short periods of time. Each time, a reduction in power of approximately 10-percent was sufficient to reestablish nucleate boiling on the surface of the rod. During these and subsequent tests, no adverse effects were observed on this rod or any other rod in the bundle as a consequence of operating in DNB.

Hydrodynamic and Flow Power Coupled Instability Thermohydrodynamic instabilities will not occur under Condition I and II modes of operation for Westinghouse PWR reactor designs. A large power margin exists to predicted inception of such instabilities. Analysis has been performed which shows that minor plant to plant differences in Westinghouse reactor designs such as fuel assembly arrays, core power to flow ratios and fuel assembly length will not result in gross deterioration of the above power margins.

3.2.2.5 Hydraulic Compatibility 3.2.2.5.1 Transition Core Effects The entire core is now 15x15 Upgraded fuel therefore there are no transition core effects.

3.2.2.5.2 DNB Performance When Transitioning Cores Chapter 3, Page 35 of 94 Revision 25, 2014

IP2 FSAR UPDATE The Westinghouse transition core DNB methodology is given in References 90, 91, and 92 and has been approved by the NRC via Reference 93 and 94. Using this methodology, transition cores are analyzed as if the entire core consists of one assembly type.

3.2.2.5.3 Compatibility The hydraulic resistance of the two assemblies is based on full scale hydraulic flow test data.

The design hydraulic loss coefficients are verified with a confirmatory hydraulic test in the Fuel Assembly Compatibility Test System (FACTS). The results are evaluated to determine the values of the pressure drop loss coefficients.

Fuel assembly vibration testing is conducted to confirm that the fuel assembly does not experience flow-induced vibration. Hydraulic vibration tests are performed in the FACTS test loop.

Side-by-side VIPER tests are performed. Test results are used to demonstrate the acceptable fretting behavior design between the two designs is insignificant.

A crossflow analysis using the THINC code is completed to determine the crossflow velocity profile in the transition core in the IP2 plant conditions. The crossflow is caused by the mid-grid and IFM pressure drop mismatch between adjacent fuel assemblies.

3.2.2.6 Effects of Rod Bow on DNBR The phenomenon of fuel rod bowing, as described in Reference 80 must be accounted for in the DNBR safety analysis of Condition I and Condition II events for each plant application.

Applicable generic credits for margin resulting from retained conservatisms in the evaluation of DNBR can be used to offset the effects of rod bow.

For safety analysis of Indian Point Unit 2, sufficient margin was maintained in the design of the fuel [Note - Margin maintained between design limit DNBR and safety analysis limit DNBR +As a result of analyses performed for OFA transition, maintaining plugging devices in core is optional.] to accommodate full and low flow rod bow DNBR penalties (less than 1-percent for the worst cast, which is at a burnup of 24,000 MWd/MTU identified in Reference 81) with the incorporation of the L2/I scaling factor (I=bending moment of inertia, L=span length) to account for the 9-grid fuel span lengths. The rod bow DNBR penalties in the Intermediate Flow Mixer (IFM) grid spans are less than those in the mixing vane grid spans.

The maximum rod bow penalties accounted for in the design safety analysis are based on an assembly average burnup of 24,000 MWd/MTU. At burnups greater than 24,000 MWd/MTU, credit is taken for the effect of F-delta-H burndown, due to the decrease in fissionable isotopes and the buildup of fission product inventory, and no additional rod bow penalty is required.

3.2.3 Mechanical Design And Evaluation The reactor core and reactor vessel internals are shown in cross-section in Figure 3.2-46 and in elevation in Figure 3.2-47. The core, consisting of the fuel assemblies, control rods, source rods, burnable poison rods, and plugging devices+, provides and controls the heat source for the reactor operation.

Chapter 3, Page 36 of 94 Revision 25, 2014

IP2 FSAR UPDATE The internals, consisting of the upper and lower core support structure, are designed to support, align, and guide the core components, direct the coolant flow to and from the core components, and to support and guide the incore instrumentation. A listing of the core mechanical design parameters is given in Table 3.2-7.

The fuel assemblies are arranged in a checkerboard and/or roughly circular zoned pattern. The fuel assemblies contain fuel of different enrichments depending on the location of the assembly within the core.

The fuel is in the form of slightly enriched uranium-dioxide ceramic pellets. The pellets are stacked to an active height of 144-in. (previously 142 in.) within ZIRLOTM (previously Zircaloy-4) tubular cladding, which is plugged and seal welded at the ends to encapsulate the fuel. The enrichments of the fuel for the first three regions in the core are given in Table 3.2-7. Reload fuel enrichment may vary up to the maximum value allowed in the Technical Specifications.

Heat generated by the fuel is removed by demineralized light water, which flows upward through the fuel assemblies and acts as both moderator and coolant.

The core is divided into fuel assembly regions of different enrichments. The loading arrangement for the initial cycle is indicated on Figure 3.2-48. In the past refueling took place generally in accordance with an inward loading schedule. Starting from Cycle 6 a low leakage loading pattern for core refueling design has been adopted and starting from Cycle 13, a low, low leakage loading pattern was used. This will reduce neutron fluence at the reactor vessel wall.

The control rods, designated as rod cluster control assemblies, consist of groups of individual absorber rods, which are held together by a spider assembly at the top end and actuated as a group. In the inserted position, the absorber rods fit within hollow guide thimbles in the fuel assemblies. The guide thimbles are an integral part of the fuel assemblies and occupy locations within the regular fuel rod pattern where fuel rods have been deleted. In the withdrawn position, the absorber rods are guided and supported laterally by guide tubes, which form an integral part of the upper core support structure. Figures 3.2-49 and 3.2-50 show a typical rod cluster control assembly in a fuel assembly. As shown in Figure 3.2-47, the fuel assemblies are positioned and supported vertically in the core between the upper and lower core plates. The core plates are provided with pins, which index into closely fitting mating holes in the fuel assembly top and bottom nozzles. The pins maintain the fuel assembly alignment, which permits free movement of the control rods from the fuel assembly into the guide tubes in the upper support structure without binding or restriction between the rods and their guide surfaces.

Operational or seismic loads imposed on the fuel assemblies are transmitted through the core plates to the upper and lower support structures and ultimately to the internals support ledge at the pressure vessel flange in the case of vertical loads or to the lower radial support and internals support ledge in the case of horizontal loads. The internals also provide a form fitting baffle surrounding the fuel assemblies, which confine the upward flow of coolant in the core area to the fuel bearing region.

3.2.3.1 Reactor Internals 3.2.3.1.1 Design Description The reactor internals are designed to support and orient the reactor core fuel assemblies and control rod assemblies, absorb the control rod dynamic loads, and transmit these and other Chapter 3, Page 37 of 94 Revision 25, 2014

IP2 FSAR UPDATE loads to the reactor vessel flange, provide a passageway for the reactor coolant, and support incore instrumentation. The reactor internals are shown in Figure 3.2-47.

The internals have been designed to withstand the forces due to weight, preload of fuel assemblies, control rod dynamic loading, vibration, and earthquake acceleration. The internals were analyzed in a manner similar to Connecticut Yankee, San Onofre, Zorita, Saxton, and Yankee. Under the loading conditions, including conservative effects of design earthquake loading, the structure satisfies stress values prescribed in Section III, ASME Nuclear Vessel Code.

The reactor internals are equipped with bottom-mounted incore instrumentation supports.

These supports are designed to sustain the applicable loads outlined above.

The components of the reactor internals are divided into three parts consisting of the lower core support structure (including the entire core barrel and thermal shield), the upper core support structure, and the incore instrumentation support structure.

3.2.3.1.1.1 Lower Core Support Structure The major component and support member of the reactor internals is the lower core support structure, shown in Figure 3.2-51. This support structure assembly consists of the core barrel, the core baffle, the lower core plate and support columns, the thermal shield, the intermediate diffuser plate, and the bottom support plate, which is welded to the core barrel. All the major material for this structure is type 304 stainless steel. The core support structure is supported at its upper flange from a ledge in the reactor vessel head flange and its lower end is restrained in its transverse movement by a radial support system attached to the vessel wall. Within the core barrel are axial baffle and former plates, which are attached to the core barrel wall and form the enclosure periphery of the assembled core. The lower core plate is positioned at the bottom level of the core below the baffle plates and provides support and orientation for the fuel assemblies.

The lower core plate is a 2-in. thick member through which the necessary flow distributor holes for each fuel assembly are machined. Fuel assembly locating pins (two for each assembly) are also inserted into this plate. Columns are placed between this plate and the lower core support of the core barrel in order to provide stiffness and to transmit the core load to the lower core support. Intermediate between the support plate and lower core support plate a perforated plate is positioned to diffuse uniformly the coolant flowing into the core.

The one-piece thermal shield is fixed to the core barrel at the top with rigid bolted connections.

The bottom of the thermal shield is connected to the core barrel by means of axial flexures.

This bottom support allows for differential axial growth of the shield with respect to the core barrel but restricts radial or horizontal movement of the bottom of the shield. Rectangular tubing, in which vessel material samples can be inserted and irradiated during reactor operation, are welded to the thermal shield and extend to the top of the thermal shield. These samples are held in the rectangular tubing by a preloaded spring device at the top and bottom.

The lower core support structure and principally the core barrel serve to provide passageways and control for the coolant flow. Inlet coolant flow from the vessel inlet nozzles proceeds down the annulus between the core barrel and the vessel wall, flows on both sides of the thermal shield, and then into a plenum at the bottom of the vessel. It then turns and flows up through the lower support, passes through the intermediate diffuser plate and then through the lower core plate. The flow holes in the diffuser plate and the lower core are arranged to give a very Chapter 3, Page 38 of 94 Revision 25, 2014

IP2 FSAR UPDATE uniform entrance flow distribution to the core. After passing through the core, the coolant enters the area of the upper support structure and then flows generally radially to the core barrel outlet nozzles and directly through the vessel outlet nozzles.

A small amount of water also flows between the baffle plates and core barrel to provide additional cooling of the barrel. Similarly, a small amount of the entering flow is directed into the vessel head plenum to provide cooling of the head. Both these flows eventually are directed into the upper support structure plenum and exit through the vessel outlet nozzles.

Vertically downward loads from weight, fuel assembly preload, control rod dynamic loading, and earthquake acceleration are carried by the lower core plate partially into the lower core plate support flange on the core barrel shell and partially through the lower support columns to the lower core support and then through the core barrel shell to the core barrel flange supported by the vessel head flange. Transverse loads from earthquake acceleration, coolant cross flow, and vibration are carried by the core barrel shell to be distributed to the lower radial support to the vessel wall, and to the core barrel flange. Transverse acceleration of the fuel assemblies is transmitted to the core barrel shell by direct connection of the lower core plate to the barrel wall and by a radial support type connection of the upper core plate to slab-sided pins pressed into the core barrel.

The main radial support system of the core barrel is accomplished by "key" and "keyway" joints to the reactor vessel wall. At equally spaced points around the circumference, an Inconel block is welded to the vessel inside diameter. Another Inconel block is bolted to each of these blocks, and has a "keyway" geometry. Opposite each of these is a "key", which is attached to the internals. At assembly, as the internals are lowered into the vessel, the keys engage the keyways in the axial direction. With this design, the internals are provided with a support at the furthest extremity, and may be viewed as a beam fixed at the top and simply supported at the bottom.

Radial and axial expansions of the core barrel are accommodated but transverse movement of the core barrel is restricted by this design. With this system, cycle stresses in the internal structures are within the ASME Section III limits. This eliminates any possibility of failure of the core support.

In the event of downward vertical displacement of the internals, energy absorbing devices limit the displacement by contacting the vessel bottom head. The load is transferred through the energy devices of the internals.

The energy absorbers, cylindrical in shape, are contoured on their bottom surface to the reactor vessel bottom head geometry. Their number and design are determined so as to limit the forces imposed to less than yield. Assuming a downward vertical displacement, the potential energy of the system is absorbed mostly by the strain energy of the energy absorbing devices.

The free fall in the hot condition is on the order of 0.50-in. and there is an additional strain displacement in the energy absorbing devices of approximately 0.75-in. Alignment features in the internals prevent cocking of the internals structure during this postulated drop. The control rods are designed to provide assurance of control rod insertion capabilities under this assumed drop of internals condition. The drop distance of about 1.25-in. is not enough to cause the tips of the shutdown group of rod cluster control assemblies to come out of the guide tubes in the fuel assemblies.

Chapter 3, Page 39 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.3.1.1.2 Upper Core Support Assembly The upper core support assembly, shown in Figure 3.2-52, consists of the top support plate, deep beam sections, and upper core plate between which are contained 48 support columns and 61 guide tube assemblies. The support columns establish the spacing between the top support plate, deep beam sections, and the upper core plate. They are fastened at top and bottom to these plates and beams. The support columns transmit the mechanical loadings between the two plates and serve the supplementary function of supporting thermocouple guide tubes. The guide tube assemblies, shown on Figure 3.2-53, sheath and guide the control rod drive shafts and control rods and provide no other mechanical functions. They are fastened to the top support plate and are guided by pins in the upper core plate for proper orientation and support. Additional guidance for the control rod drive shafts is provided by the control rod shroud tube, which is attached to the upper support plate and guide tube.

The upper core support assembly, which is removed as a unit during refueling operation, is positioned in its proper orientation with respect to the lower support structure by flat-sided pins pressed into the core barrel, which in turn engage in slots in the upper core plate. At an elevation in the core barrel where the upper core plate is positioned, the flat-sided pins are located at angular positions of 0, 90, 180, and 270 degrees. Four slots are milled into the core plate at the same positions. As the upper support structure is lowered into the main internals, the slots in the plate engage the flat-sided pins in the axial direction. Lateral displacement of the plate and of the upper support assembly is restricted by this design. Fuel assembly locating pins protrude from the bottom of the upper core plate and engage the fuel assemblies as the upper assembly is lowered into place. Proper alignment of the lower core support structure, the upper core support assembly, the fuel assemblies and control rods is thereby assured by this system of locating pins and guidance arrangement. The upper core support assembly is restrained from any axial movements by a large circumferential spring, which rests between the upper barrel flange and the upper core support assembly and is compressed by the reactor vessel head flange.

Vertical loads from weight, earthquake acceleration, hydraulic loads, and fuel assembly preload are transmitted through the upper core plate via the support columns to the deep beams and top support plate and then to the reactor vessel head. Transverse loads from coolant cross flow, earthquake acceleration, and possible vibrations are distributed by the support columns to the top support plate and upper core plate. The top support plate is particularly stiff to minimize deflection.

3.2.3.1.1.3 Incore Instrumentation Support Structures The incore instrumentation support structures consist of an upper system to convey and support thermocouples penetrating the vessel through the head and a lower system to convey and support flux thimbles penetrating the vessel through the bottom.

The upper system utilizes the reactor vessel head penetrations. Instrumentation port columns are slip-connected to inline columns that are in turn fastened to the upper support plate. These port columns protrude through the head penetrations. The thermocouples are carried through these port columns and the upper support plate at positions above their readout locations. The thermocouple conduits are supported from the columns of the upper core support system. The thermocouple conduits are sealed stainless steel tubes.

Chapter 3, Page 40 of 94 Revision 25, 2014

IP2 FSAR UPDATE In addition to the upper incore instrumentation, there are reactor vessel bottom port columns, which carry the retractable, cold-worked stainless steel flux thimbles that are pushed upward into the reactor core. Conduits extend from the bottom of the reactor vessel down through the concrete shield area and up to a thimble seal line. The minimum bend radii are about 144-in.

and the trailing ends of the thimbles (at the seal line) are extracted approximately 15-ft during refueling of the reactor in order to avoid interference within the core. The thimbles are closed at the leading ends and serve as the pressure barrier between the reactor pressurized water and the containment atmosphere.

Mechanical seals between the retractable thimbles and the conduits are provided at the seal line. During normal operation, the retractable thimbles are stationary and move only during refueling or for maintenance, at which time a space of approximately 15-ft above the seal line is cleared for the retraction operation. Sections 7.4 and 7.6 contain more information on the layout of the incore instrumentation system. The incore instrumentation support structure is designed for adequate support of instrumentation during reactor operation and is rugged enough to resist damage or distortion under the conditions imposed by handling during the refueling sequence.

3.2.3.1.2 Evaluation of Core Barrel and Thermal Shield The internals design is based on analysis, test, and operational information. Troubles in previous Westinghouse PWRs have been evaluated and information derived has been considered in this design. For example, the Westinghouse design uses a one-piece thermal shield, which is attached rigidly to the core barrel at one end and flexured at the other. The early designs that malfunctioned were multi-piece thermal shields that rested on vessel lugs and were not rigidly attached at the top.

Early core barrel designs that have malfunctioned in service, now abandoned, employed threaded connections such as tie rods, joining the bottom support to the bottom of the core barrel, and a bolted connection that tied the core barrel to the upper barrel. The malfunctioning of core barrel designs in earlier service was believed to have been caused by the thermal shield, which was oscillating, thus creating forces on the core barrel. Other forces were induced by unbalanced flow in the lower plenum of the reactor. In today's rod cluster control design there are no fuel followers to necessitate a large bottom plenum in the reactor. The elimination of these fuel followers enabled Westinghouse to build a shorter core barrel.

The Connecticut Yankee reactor and the Zorita reactor core barrels are of the same construction as the Indian Point Unit 2 reactor core barrel. Deflection measuring devices employed in the Connecticut Yankee reactor during the hot functional test, and deflection and strain gauges employed in the Zorita reactor during the hot-functional test provided important information that was used in the design of the present day internals, including that for Indian Point. When the Connecticut Yankee thermal shield was modified to the same design as for Southern California Edison, it, too, operated satisfactorily as was evidenced by the examination after the hot-functional test. After hot-functional tests on all of these reactors, a careful inspection of the internals was examined for any differential movement; upper core plate inside supports were examined, and the thermal shield attachments to the core barrel, including all lockwelds on the devices used to lock the bolt, were checked; no malfunctions were found.

Substantial scale model testing was performed at WAPD. This included tests, which involved a complete full-scale fuel assembly, which was operated at reactor flow, temperature, and pressure conditions. Tests were run on a one-seventh scale model of the Indian Point Unit 2 reactor. Measurements taken from those tests indicated very little shield movement, on the Chapter 3, Page 41 of 94 Revision 25, 2014

IP2 FSAR UPDATE order of a few mils when scaled up to Indian Point Unit 2. Strain gauge measurements taken on the core barrel also indicated very low stresses. Testing to determine thermal shield excitation due to inlet flow disturbances was included. Information gathered from these tests was used in the design of the thermal shield and core barrel. It was concluded, from the experience gained during the testing program and the analyses, that the design as employed on the Indian Point Unit 2 plant is adequate.

In order to confirm the internals design, deflection gauges were mounted on the thermal shield top and bottom for the hot-functional test. Gauges were mounted in the top of the thermal shield equidistant from the fixed supports, and at the bottom of the thermal shield, equidistant from the six flexures, and next to the flexure supports. The internals inspection, just before the hot-functional test, included looking at mating bearing surfaces, main welds, and welds that are used on bolt locking devices. At the conclusion of the hot-functional test, measurement readings were taken from the deflectometers on the shield and the internals were re-examined at all key areas for any evidence of malfunction.

3.2.3.2 Core Components 3.2.3.2.1 Design Description 3.2.3.2.1.1 Fuel Assembly The 15x15 Upgraded fuel assembly, introduced in Cycle 17, is shown in Figure 3.2-61C. The assemblies are square in cross section, nominally 8.426-in. on a side, and have an overall height of approximately 159.975 inches. The fuel rods in a fuel assembly are arranged in a square array with 15 rod locations per side and a nominal centerline-to-centerline pitch of 0.563-in. between rods. Of the total possible 225 rod locations per assembly, 20 are occupied by guide thimbles for the rod cluster control rods and one for incore instrumentation. The remaining 204 locations contain fuel rods. In addition to fuel rods, a fuel assembly is composed of a top nozzle, a bottom nozzle, ten grid assemblies (plus 3 intermediate flow mixing grids starting with Cycle 13), 20 absorber rod guide thimbles, and one instrumentation thimble.

The guide thimbles in conjunction with the grid assemblies and the top and bottom nozzles comprise the basic structural fuel assembly skeleton. The grid assemblies are bulge attached to the guide thimbles at each location along the height of the fuel assembly at which lateral support for the fuel rods is required. Within this skeletal framework the fuel rods are contained and supported and the rod-to-rod centerline spacing is maintained along the assembly.

The original fuel design for Indian Point 2 was the Westinghouse High Parasitic (HIPAR) fuel assembly. This consisted of Zircoloy clad fuel rods, 9 Inconel grids and stainless steel instrumentation and guide thimbles. Burnable absorbers used were pyrex glass.

Starting with Cycle 5, the Westinghouse Low Parasitic (LOPAR) fuel assembly was introduced.

This design consisted of Zircaloy-4 clad fuel rods, 9 Inconnel grids and Zircaloy-4 instrumentation and guide thimbles.

For the Cycle 8, Wet Annular Burnable Absorbers (WABA) were introduced.

For Cycle 10, the Westinghouse Optimized Fuel Assembly (OFA) was introduced. This consisted of Zircaloy-4 clad fuel rods, 2 Inconel grids (top & bottom), 7 Zircaloy-4 grids and Zircaloy-4 instrumentation and guide thimbles. In addition, thimble plugs were removed from the core this cycle based on analysis performed to support removal. The assembly top nozzle Chapter 3, Page 42 of 94 Revision 25, 2014

IP2 FSAR UPDATE design was changed to a Reconstitutable Top Nozzle (RTN) design to facilitate reconstitution of failed fuel.

For Cycle 11, the OFA fuel assembly design incorporated Debris Filter Bottom Nozzles (DFBN) and Integral Fuel Burnable Adsorbers (IFBA).

For Cycle 13, the Westinghouse Vantage+ fuel design was introduced (see Figures 3.2-54 and 3.2-56B). This design included ZIRLO clad fuel rods, 2 Inconel grids, 7 low pressure drop (LPD) Zircaloy-4 grids, 3 Zircaloy Integral Flow Mixing grids (IFM), ZIRLO instrumentation and guide thimbles, annular axial blankets along with the DFBN, IFBA and RTN. Use of WABAs was continued. See Reference 13.

For Cycle 15, the Vantage+ fuel assembly design incorporated Performance+ features of ZIRLO grids and IFMs and a hardened coating of zirconium oxide on the bottom section of the fuel rod clad to increase debris resistance.

For Cycle 16, the Vantage+ fuel assembly design was further enhanced with Performance+

features that include debris mitigation features of an additional grid located at the bottom end plug of the fuel rod, a longer fuel rod end plug and a revised DFBN. Other performance+

enhancements include longer fuel rods and longer annual axial blanket (see Figure 3.2-61B).

In addition to the above fuel design changes, the design burnup of the fuel assemblies has also been increasing to 62,000 MWD/MTU lead rod burnup for Cycle 16. See References 15, 16 and 17.

For Cycle 17, the 15x15 Upgraded fuel assembly design was used. This design has features to address grid-to-rod fretting fuel failures. These include I-spring mid-grids, enhanced IFMs and balanced mixing vanes. In addition, the tube-in-tube thimble design was incorporated with a single-dashpot, which improves straightness.

For Cycle 18, solid axial blanket pellets were introduced for the non-IFBA fuel rods.

For Cycle 19, the top nozzle spring design was changed from the Vantage+ design to the standard spring design.

Cycle 20 and 21 fuel was the same as Cycle 19, there were no fuel design changes.

Cycle 22 uses the 15x15 Upgraded design with changes to the bottom nozzle and the protective grid. Five flow holes on each side of the bottom nozzle were removed to eliminate possible debris intrusion into the fuel through the holes. It is now the modified Debris Filter Bottom Nozzle (mDFBN). The manufacturing of the protective grid was changed to prevent dimple cracking. It is now the Robust Protective Grid (RPG). In addition, secondary sources were removed from the core.

Bottom Nozzle Two types of nozzle designs were used for the HIPAR fuel assemblies. One type, which is square in cross section, is fabricated from type 304 stainless steel consisting of four side plates, 12 cross bars and four pads or feet. The side plates are welded together at the corners to form a plenum for inlet coolant to the fuel assembly. The cross bars are welded at each end to the top edges of the side plate and function as the bottom end support for the fuel rods. The bottom support surface for the fuel assembly is formed by the four pads, which are welded to the side Chapter 3, Page 43 of 94 Revision 25, 2014

IP2 FSAR UPDATE plates in the corners. This design was used in a majority of the first core fuel assemblies. The previously used LOPAR and OFA fuel incorporate an equivalent bottom nozzle design utilizing a square perforated plate rather than the cross bars and side plate. On both designs, their respective cross bars and perforated plate prevent the fuel rods from falling through the bottom nozzles of the assembly.

Coolant flow to the fuel assembly is directed from the plenum in the bottom nozzle upward to the interior of the fuel assembly and to the channel between assemblies.

Axial loads imposed on the assembly, as well as the weight of the assembly are distributed through the guide thimble and the bottom nozzle to the lower core support plate. Indexing and positioning of the fuel assembly in the core is controlled through two holes in diagonally opposite pads, which mate with locating pins in the lower core plate. Lateral loads imposed on the fuel assembly are also transferred to the core support structures through the locating pins.

The OFA and VANTAGE+ bottom nozzle used the reconstitutable feature found on the previously installed LOPAR fuel design, which uses a locking cup to lock the thimble screws on the guide thimble assembly, instead of the lockwire used in earlier LOPAR designs. The OFA nozzle assembly is shorter when compared to the previously installed LOPAR assembly to enhance fuel rod growth allowances.

The two bottom nozzle designs used in the OFAs are both square in cross section and fabricated from 304 stainless steel. The design used in earlier regions consists of a perforated plate, four angle legs, and four pads of feet. The angle legs are fastened to the plate forming a plenum space for the coolant inlet to the fuel assembly.

The remaining OFA regions and the VANTAGE+ and 15x15 Upgraded fuel regions (starting with Cycle 13, Region 15) incorporate an equivalent bottom nozzle design denoted as the Debris Filter Bottom Nozzle (DFBN). This nozzle adds side plates or "skirts" to the previous design increasing structural capability for abnormal loads and providing a more defined plenum space below the nozzle. Additionally, the relatively large adapter plate flow holes of the earlier design are replaced with a new pattern of smaller flow holes. The decrease in size of the holes provides a "screen" for larger debris particles, which would otherwise cause damage if allowed to pass into the assembly.

In both designs, the adaptor plates prevent accidental downward ejection of the fuel rods from the fuel assembly. The nozzles are fastened to the assembly guide tubes by stainless steel screws, which penetrate through the nozzle and mate with a threaded plug in each guide tube (Figure 3.2-57). The screw possesses a circular locking cup around the screw head, which is crimped into mating detentes (lobes) on the bottom nozzle, preventing the screw from loosening.

The DFBN was modified starting with Cycle 22 to eliminate five holes on each side (mDFBN) to eliminate the potential for intrusion of debris.

Top Nozzle The Reconstitutable Top Nozzle (RTN) used in both the OFA, VANTAGE+ and 15x15 Upgraded fuel assemblies is a box-like structure, which functions as the fuel assembly upper structural element and forms a plenum space where the heated fuel assembly discharge coolant is mixed and directed toward the flow holes in the upper core plate. The nozzle is comprised of an adaptor plate enclosure, top plate, clamps, hold-down leaf springs and assorted hardware.

Chapter 3, Page 44 of 94 Revision 25, 2014

IP2 FSAR UPDATE Each nozzle has four sets of leaf springs. All parts, with the exception of the springs and their hold-down bolts/screws, are constructed of type 304 stainless steel. The springs are made from age hardenable Inconel 718 and the bolts/screws from Inconel 600 for Region 16 and earlier regions, and from shotpeened Inconel 718 for Regions 17 and 18.

The adaptor plate portion of the nozzle is square in cross section, and is perforated by machined slots to provide for coolant flow through the plate. At assembly, the top ends of the LOPAR thimble stainless sleeves are fitted through individual bored holes in the plate and welded to the plate around the circumference of each hole. In the OFA removable top nozzle design, a groove is provided in each thimble thru-hole in the nozzle plate into which a stainless steel nozzle insert is mechanically connected by means of a preformed circumferential bulge near the top of the insert. Thus, the adaptor plate acts as the fuel assembly top end plate, and provides a means of distributing evenly among the guide thimbles any axial loads imposed on the fuel assemblies.

The nozzle enclosure is actually a square tubular structure, which forms the plenum section of the top nozzle. The bottom end of the enclosure is pinned and welded to the periphery of the adaptor plate and the top end is welded to the periphery of the top plate.

The top plate is square in cross section with a square central hole. The hole allows clearance for the rod cluster control absorber rods to pass through the nozzle into the guide thimbles in the fuel assembly and for coolant exit from the fuel assembly to the upper internals area. Two pads containing axial through-holes, which are located on diametrically opposite corners of the top plate provide a means of positioning and aligning the top of the fuel assembly. As with the bottom nozzle, alignment pins in the upper core plate mate with the holes in the top nozzle plate. Hold-down forces of sufficient magnitude to oppose the hydraulic lifting forces on the fuel assembly are obtained by means of the leaf spring sets, which are mounted on the top plate.

The springs are fastened in pairs to the top plate at the two corners where alignment holes are not used and radiate out from the corners parallel to the sides of the plate. Fastening of each pair of springs is accomplished with a clamp, which fits over the ends of the springs and two bolts/screws (one per spring set), which pass through the clamp and spring, and thread into the top plate. At assembly, the spring mounting bolts/screws are torqued sufficiently to preload against the maximum spring load and then lockwelded to the clamp, which is counterbored to receive the bolt/screw head. The spring load is obtained through deflection of the spring pack by the upper core plate. The spring pack form is such that it projects above the fuel assembly and is depressed by the core plate when the internals are loaded into the reactor. The free end of the spring pack is bent downward and captured in a key slot in the top plate to guard against loose parts in the reactor in the event (however remote) of spring fracture. The capture of the loose end has been deleted in latter designs.

Starting with Cycle 14, Region 16, the fuel has a cast top nozzle. This is a two-piece design incorporating a machined stainless steel adapter plate welded to a low-cobalt investment casting. The cast top nozzle is functionally interchangeable with the previous design and meets design criteria for the top nozzle.

In addition to its plenum and structural functions, the nozzle provides a protective housing for components, which mate with the fuel assembly. In handling a fuel assembly with a control rod inserted, the control rod spider is contained within the nozzle. During operation in the reactor, the nozzle protects the absorber rods from coolant cross flows in the unsupported span between the fuel assembly adaptor plate and the end of the guide tube in the upper internals package. Plugging devices, [Note - As a result of analyses performed for OFA transition, maintaining plugging devices in the core is optional. ], which fill the ends of the fuel assembly Chapter 3, Page 45 of 94 Revision 25, 2014

IP2 FSAR UPDATE thimble tubes at unrodded core locations and the source rods and burnable absorber rods, are all contained within the fuel top nozzle.

For the RTN design, a stainless steel nozzle insert is mechanically connected to the top nozzle adaptor plate (Figure 3.2-58A) via the engagement of the preformed circumferential bulge near the top of the insert and the mating groove in the wall of the adapter plate thimble tube through-hole. The insert has four equally spaced axial slots, which allow the insert to deflect inwardly at the elevation of the bulge, thus permitting the installation and removal of the nozzle. The insert bulge is positively held in the adapter plate mating groove by placing a lock tube with a uniform OD identical to that of the thimble tube into the insert. The lock tube is secured in place by a top flare, which creates a tight fit and six non-yielding projections on the OD, which interface with the concave side of the insert to preclude escape during core component transfer. The adaptor plate acts as the fuel assembly top end plate and provides a means of evenly distributing any axial loads imposed on the fuel assemblies to the guide thimbles.

Guide Thimbles The control rod guide thimbles in the fuel assemblies provide guided channels for the absorber rods during insertion and withdrawal of the control rods. Up to and including Region 18 (VANTAGE+), they are fabricated from a single piece of tubing, which is drawn to two different diameters. The OFA thimbles are Zircaloy-4 and the VANTAGE+ thimble material ZIRLOTM.

The larger inside diameter at the top provides a relatively large annular area for rapid insertion during a reactor trip and accommodates a small amount of upward cooling flow during normal operations. The bottom portion of the guide thimble has two sections of reduced diameter producing a "double dashpot" action when the absorber rods near the end of travel in the guide thimbles during a reactor trip. The transition zones at the dashpot sections are conical in shape so that there are no rapid changes in diameter in the tube.

Starting with Region 19 (15x15 Upgraded fuel design), the guide thimbles incorporate the tube-in-tube dashpot design. The tube-in-tube design utilizes a separate dashpot tube assembly that is inserted into the guide thimble assembly pulled to a press fit over the thimble end plug and bulged into place. To maintain the same diametrical clearance between the guide thimble ID and the dashpot OD, the 15x15 upgraded nominal dashpot thickness was reduced from 0.0165 to 0.0160 inches. As the dashpot tube in the design can provide additional lateral support in that bottom thimble span, it is expected that there will be additional resistance to lateral deformation and Incomplete Rod Insertions as a result of the design modification. The 15x15 Upgraded fuel thimbles are ZIRLOTM.

Flow holes are provided just above the first dashpot transition to permit the entrance of cooling water during normal operation, and to accommodate the outflow of water from the dashpot during reactor trip.

The dashpot is open at the bottom by means of the drainage hole in the thimble screws that secure the bottom nozzle to the welded end plugs of the guide thimbles. This geometry is shown in Figure 3.2-57.

The top ends of the thimble tubes are mechanically attached to the sleeve of the top grid. An insert is also bulge attached to the thimble and the insert upper end is in turn mechanically attached to the top nozzle as shown in Figure 3.2-58A.

Chapter 3, Page 46 of 94 Revision 25, 2014

IP2 FSAR UPDATE VANTAGE+ Grids Prior to Region 18, the VANTAGE+ assembly has twelve grids. Starting with Region 18, a thirteenth grid, the protective grid (P-grid), was added to the VANTAGE+ assembly. The top and bottom grids, as in the OFA assembly, and the P-grid are Inconel 718 non-mixing vane grids. The top and bottom grids are Inconel-718 non-mixing vane grids. Low Pressure Drop (LPD) Zircaloy grids are used for the middle grids with Zircaloy IFMs located in the three uppermost middle grid spans. The VANTAGE+ fuel assembly with PERFORMANCE+ options has ZIRLO grids for the 3IFMs and 7 mid grids. The LPD grids have mixing vanes, diagonal springs and a reduced grid height, relative to the OFA grids. The LPD grid cells use the standard four dimples and two springs per cell for support locations. The IFMs provide mid-span flow mixing in the hottest fuel assembly spans. Each IFM cell contains four dimples, which are designed to prevent midspan channel closure and fuel rod contact with the mixing vanes.

With the additional Performance+ enhancements added to the fuel starting with Region 18, a new Protective Bottom Grid (PBG) has been added. The PBG is a wider, extra grid at the very bottom of the fuel assembly that protects the fuel from debris. Its purpose is to filter out debris and hold it at an elevation below the bottom of the active core. The PBG is not a structural grid.

The bottom of the PBG lies below the tops of the lower end plugs within the fuel rod. This means that any debris caught in the PBG cannot fret through the cladding and expose fuel pellets.

All VANTAGE+ outside grid straps contain mixing vanes, which also act as guides during fuel handling. The grids are also attached to the thimble tubes via the bulging mechanism as shown in Figure 3.2-61A. Top grid nozzle attachment is shown in Figure 3.2-58A. All grids employ the anti-snag outer strap design. A mixing vane grid is shown in Figure 3.2-59.

15x15 Upgraded Design Grids The 15x15 Upgraded fuel design still contains twelve grids with the top and bottom grids unchanged from the Vantage+ design. The thirteenth grid, the protective gird (P-grid) also remains the same as the Vantage+ design. The middle grids have changed to an I-spring design. The changes were made to improve fuel rod fretting margin. In addition to the spring change the size of the dimples was increased. The strap thickness was decreased to help offset pressure drop increase due to the I-spring and increased grid strap height. The strap height increased to create space to accommodate the increased dimples and the I-spring. The IFM grid design was enhanced to increase contact area also.

The 15x15 Upgraded design protective grid has been redesigned for Cycle 22 to reduce stresses that caused dimple cracking. The Robust Protective Grid (RPG) dimensions changed and vibration mitigation features were added.

Fuel Rods The fuel rods consist of uranium-dioxide ceramic pellets in slightly cold worked ZIRLOTM tubing, which is plugged and seal welded at the ends to encapsulate the fuel. Sufficient void volume and clearances are provided within the rod to accommodate fission gases released from the fuel, differential thermal expansion between the cladding and the fuel, helium released from poison burnup (IFBA rods), and fuel swelling due to accumulated fission products without overstressing of the cladding or seal welds. Shifting of the fuel within the cladding is prevented during handling or shipping prior to core loading by a stainless steel helical compression spring, which bears on the top of the fuel.

Chapter 3, Page 47 of 94 Revision 25, 2014

IP2 FSAR UPDATE At assembly, the pellets are stacked in the cladding to the required fuel height. The compression spring is then inserted into the top end of the fuel and the end plugs pressed into the ends of the tube and welded. A hold-down force of approximately four times the weight of the fuel is obtained by compression of the spring between the top end plug and the top of the fuel pellet stack. All fuel rods are internally pressurized with helium in order to minimize compressive clad stresses and creep due to coolant operating pressures.

The fuel pellets are in the form of a right circular cylinder and consist of slightly enriched uranium-dioxide powder, which is compacted by cold pressing and sintering to the required density. The ends of each pellet are dished slightly to allow the greater axial expansion at the center of the pellets to be taken up within the pellets themselves and not in the overall fuel length. The 15x15 Upgrade fuel has mid-enriched annular (IFBA) and solid (non-IFBA) pellets in the axial blanket region of the fuel rod and optimized plenum spring to maximize the available plenum volume for increased burnup. The 15x15 Upgrade fuel has a longer fuel rod to allow higher fission gas release due to longer cycles. This is allowable due to the ZIRLO cladding, which has less rod growth on irradiation.

For the first core, the pellets in the outer region had a density of approximately 10.3 g/cm3 (94-percent of theoretical density) while those in the two inner regions (checkerboard pattern, see Figure 3.2-48) had a density of 10.4 g/cm3 corresponding to 95-percent of theoretical density.

Lower pellet densities were used to compensate for the effects of the higher burnup, which the fuel experienced in those regions.

Reload cores contain 15x15 Upgraded fuel arranged in a zoned and/or checkerboard pattern.

Different fuel enrichments, as listed in Table 3.2-7, are used for each of the core regions for all core loadings.

Each fuel rod is marked with a permanent traceability code. This aids in ensuring that rods of the proper enrichment will be loaded into each fuel assembly. The identification numbers on the fuel assembly top nozzles will then maintain the enrichment identity and ensure that the assemblies with the correct enrichment are loaded into the proper core region.

Each assembly is assigned a core loading position. A record is then made of the core loading position, serial number, and enrichment. During the core loading, two independent checks are made to ensure that the actual loading position agrees with the position assigned.

During initial core loading and subsequent refueling operations, detailed handling and checkoff procedures are used throughout the sequence. The initial core was loaded in accordance with the core loading diagram similar to Figure 3.2-48, which shows the location for each of the three enrichment types of fuel assemblies used in the loading.

3.2.3.2.1.2 Rod Cluster Control Assemblies The control rods or rod cluster control assemblies consist of a group of individual absorber rods fastened at the top end to a common hub or spider assembly. These assemblies, one of which is shown in Figure 3.2-49, are provided to control the reactivity of the core under operating conditions. The absorber material used in the control rods is silver-indium-cadmium alloy, which is essentially "black" to thermal neutrons and has sufficient additional resonance absorption to increase its worth significantly. The alloy is in the form of extruded single-length rods, which are sealed in stainless steel tubes to prevent the rods from coming in direct contact with the coolant.

Chapter 3, Page 48 of 94 Revision 25, 2014

IP2 FSAR UPDATE The overall control rod length is such that when the assembly has been withdrawn through its full travel, the tips of the absorber rods remain engaged in the guide thimbles so that alignment between rods and thimbles is always maintained. Since the rods are long and slender, they are relatively free to conform to any small misalignments with the guide thimble. Prototype tests have shown that the rod cluster control assemblies are very easily inserted and not subject to binding even under conditions of severe misalignment.

The spider assembly is in the form of a center hub with radial vanes supporting cylindrical fingers from which the absorber rods are suspended. Handling detents and detents for connection to the drive shaft are machined into the upper end of the hub. A spring pack is assembled into a skirt integral to the bottom of the hub to stop the rod cluster control assembly and absorb the energy from the impact at the end of a trip insertion. The radial vanes are joined to the hub and the fingers are joined to the vanes by furnace brazing. A centerpost, which holds the spring pack and its retainer is threaded into the hub within the skirt and welded to prevent loosening in service. All components of the spider assembly are made from type 304 stainless steel except for the springs, which are Inconel X-750 alloy and the retainer, which is of 17-4 pH material.

The absorber rods are secured to the spider so as to ensure trouble free service. The rods are first threaded into the spider fingers and then pinned to maintain joint tightness, after which the pins are welded in place. The end plug below the pin position is designed with a reduced section to permit flexing of the rods to correct for small operating or assembly misalignments.

In construction, the silver-indium-cadmium rods are inserted into cold-worked stainless steel tubing, which is then sealed at the bottom and the top by welded end plugs. Sufficient diametral and end clearance are provided to accommodate relative thermal expansions and to limit the internal pressure to acceptable levels.

The bottom plugs are made bullet-nosed to reduce the hydraulic drag during a reactor trip and to guide smoothly into the dashpot section of the fuel assembly guide thimbles. The upper plug is threaded for assembly to the spider and has a reduced end section to make the joint more flexible. Stainless steel clad silver-indium-cadmium alloy absorber rods are resistant to radiation and thermal damage thereby ensuring their effectiveness under all operating conditions. Rods of similar design have been successfully used in a number of operating nuclear plants.

3.2.3.2.1.3 Neutron Source Assemblies Six neutron source assemblies were utilized in the first cycle core. These consisted of two assemblies with four secondary source rods each, and four assemblies with one secondary source rod and one primary source rod each. The rods in each assembly were fastened to a spider at the top end. The spider for the four secondary source rod assemblies was similar to the rod cluster control assembly spiders, while the primary source assembly spider was similar to that of the burnable poison and plugging device assemblies. Various source assembly designs are used in the reload cycles.

In the first cycle core, the neutron source assemblies were inserted into the rod cluster control guide thimbles in fuel assemblies at unrodded locations. The location and orientation of each of the assemblies in the core is shown in Figure 3.2-62.

The primary and secondary source rods both utilize the same type of cladding material as the absorber rods (cold-worked type 304 stainless steel tubing). The secondary source rods contain Sb-Be pellets. The primary source rods contained capsules of Pu-Be source material in Chapter 3, Page 49 of 94 Revision 25, 2014

IP2 FSAR UPDATE the initial core loading; for reload cores, this material may vary. Design criteria similar to that for the fuel rods is used for the design of the source rods; i.e., the cladding is free standing, internal pressures are always less than reactor operating pressure, and internal gaps and clearances are provided to allow for differential expansions between the source material and cladding.

Starting in Cycle 22, secondary sources are removed from the core.

3.2.3.2.1.4 Plugging Devices In order to limit bypass flow through the rod cluster control guide thimbles in fuel assemblies, which do not contain either control rods, source assemblies or burnable absorber rods, the fuel assemblies at those locations were fitted with plugging devices. The plugging devices consist of a flat plate with short rods suspended from the bottom surface and a spring pack assembly.

At installation in the core, the plugging devices fit with the fuel assembly top nozzles and rest on the adaptor plate. The short rods project into the upper ends of the thimble tubes to reduce the bypass flow area. The spring pack is compressed by the upper core plate when the upper internals package is lowered into place. Similar short rods are also used on the source assemblies to fill the ends of all vacant fuel assembly guide thimbles. All components in the plugging device, except for the springs, are constructed from type 304 stainless steel. The springs are wound from an age hardenable nickel base alloy to obtain higher strength.

Coincident with implementation of the Indian Point Unit 2 OFA transition, removal of thimble plugging devices from the core was allowed. This included the removal of the thimble plugs from the OFA assemblies, previously installed LOPAR assemblies, and all new core component clusters (burnable absorbers and sources).

As part of the implementation of the power uprate, Cycle 17 core will contain thimble plugs for all assemblies that do not contain inserts e.g. RCCAs, WABAs or secondary sources.

Starting with Cycle 21, thimble plugs have been removed from the core.

3.2.3.2.1.5 Burnable Absorber Rods The burnable absorber rods are statically suspended and positioned in vacant rod cluster control thimble tubes within the fuel assemblies at nonrodded core locations. The absorber rods in each fuel assembly are grouped and attached together at the top end of the rods by a flat plate, which fits with the fuel assembly top nozzle and rests on the top adaptor plate.

The plate with the absorber rods is held down and restrained against vertical motion with a spring pack, which is attached to the plate and is compressed by the upper core plate when the reactor upper internals package is lowered into the reactor. This ensures that the absorber rods cannot be lifted out of the core by flow forces.

The absorber rods used during Cycles 1 through 7 consisted of borated Pyrex glass tubes contained within type 304 stainless steel tubular cladding, which was plugged and seal welded at the ends to encapsulate the glass. The glass was also supported along the length of its inside diameter by a thin-wall type 304 stainless steel tubular inner liner.

Starting in Cycle 8, Wet Annular Burnable Absorber (WABA) rods were used and are described in Reference 74. As shown in Figures 3.2-69 and 3.2-70, WABA rods are composed of annular pellets containing aluminum oxide-boron carbide (Al2O3 - B4C) burnable absorber material contained within two concentric Zircaloy tubes. The Zircaloy tubes are plugged and seal welded Chapter 3, Page 50 of 94 Revision 25, 2014

IP2 FSAR UPDATE at the ends to enclose the annular stack of absorber material. The tubes are also the inner and outer cladding of the annular burnable absorber rod. A hold-down device is placed on top of the pellet stack to hold the stack in position and to allow for pellet stack growth. The hold-down device is a C-shape Zircaloy polygonal ring clip. Within the rod is an annular plenum to allow for helium gas release from the absorber material during boron depletion. Reactor coolant flows through the inner tube and outside the outer tube of the annular rod. The annular rods are grouped and attached at the top end to a hold-down assembly and retaining plate in the same way as the borosilicate glass absorber rod. WABA rods are used in preference to standard BPRAs to provide smaller residual burnup penalty.

Starting with Cycle 11, Integral Fuel Burnable Absorbers (IFBA) were used in conjunction with the WABA rods. The IFBA features a zirconium diboride coating on the fuel pellet surface on the central portion of the enriched UO2 pellets. IFBA's provide power peaking and moderator temperature coefficient control. IFBA's are described in Reference 88.

3.2.3.2.2 Evaluation of Core Components 3.2.3.2.2.1 Fuel Evaluation The fission gas release and the associated buildup of internal gas pressure in the fuel rods are calculated by overall fuel rod design models, which incorporate time-dependent fuel densification (References 68 and 69). The increase of internal pressure in the fuel rod due to this phenomena is included in the determination of the maximum cladding stresses at the end of core life when the fission product gap inventory is a maximum. Modifications to the initial core fuel design and evaluations are given in the Indian Point Unit 2 Fuel Densification Reports70 and 71

. The VANTAGE+ fuel rod design bases and evaluation are given in Reference 88. The fuel rod design has not been changed as part of the 15x15 Upgraded fuel design.

The maximum allowable tensile strain in the cladding during steady-state operation, considering the combined effects of internal gas pressure, external coolant pressure, fuel pellet swelling and thermal expansion, and cladding creep is less than 1% from the unirradiated condition throughout core life. For Condition II transients, the total tensile strain during the transient is less than 1% from the pre-transient value. The associated stresses are below the yield strength of the material under steady-state and Condition II transient conditions.

To assure that manufactured fuel rods meet a high standard of excellence from the standpoint of functional requirements, many inspections and tests are performed both on the raw material and the finished product. These tests and inspections include chemical analysis, tensile testing of fuel tubes, dimensional inspection, X-ray of both end plug welds, ultrasonic testing, and helium leak tests.

In the event of cladding defects, the high resistance of uranium-dioxide fuel pellets to attack by hot water protects against fuel deterioration or decrease in fuel integrity. Thermal stress in the pellets, while causing some fracture of the bulk material during temperature cycling, does not result in pulverization or gross void formation in the fuel matrix. As shown by operating experience and extensive experimental work in the industry, the thermal design parameters conservatively account for any changes in the thermal performance of the fuel element due to pellet fracture.

The consequences of a breach of cladding are greatly reduced by the ability of uranium-dioxide to retain fission products including those, which are gaseous or highly volatile. This Chapter 3, Page 51 of 94 Revision 25, 2014

IP2 FSAR UPDATE retentiveness decreases with increasing temperature or fuel burnup, but remains a significant factor even at full power operating temperature in the maximum burnup element.

Data on fuel behavior in high burnup uranium-dioxide show that it is possible to conservatively define the fuel swelling as a function of burnup and as-fabricated uranium-dioxide porosity (References 68 and 69).

Actual fuel rod damage limits depend upon neutron exposure and normal variation of material properties and are greater than the design limits. For the life of the fuel rod, the actual stresses and strains are below the design limits. Thus, significant margins exist between actual operating conditions and the damage limits.

The other parameters having an influence on cladding stress and strain are as follows:

1. Internal gas pressure The maximum rod internal pressure under nominal conditions will be substantially less than the calculated pressure at the design limits. The end-of-life internal gas pressure is dependent upon the fuel rod power history and will not exceed the design limit defined in Section 3.1.2.1 (item 3).
2. Cladding temperature The strength of the fuel cladding is temperature dependent. The minimum ultimate strength reduces to the design yield strength at an average cladding temperature of approximately 850°F. The maximum average cladding temperature during normal operating conditions is given in Table 3.2-6.
3. Burnup Fuel burnup results in fuel swelling, which, along with fuel thermal expansion, causes tensile cladding strain. Since rod power levels, and hence fuel temperature, decreases with burnup, the fuel pellet diameter increase with burnup is somewhat mitigated by the reduced thermal expansion. The strain design limits and stress design limits are met throughout the burnup lifetime of the fuel. These strain and stress design limits are below the cladding damage limits.
4. Fuel temperature and kW/ft The fuel is designed so that the maximum fuel temperature will not exceed 4700°F during normal operating conditions or unanticipated malfunction transients (Condition II events).

3.2.3.2.2.2 Evaluation of Burnable Absorber Rods The burnable absorber rods are positioned in the core inside rod cluster control assembly guide thimbles and held down in place by attachment to a retainer assembly compressed beneath the upper core plate and, hence, cannot be the source of any reactivity transient. Due to the low heat generation rate and the conservative design of the rods, there is no possibility for release of the poison as a result of helium pressure or clad heating during accident transients including loss-of-coolant.

Chapter 3, Page 52 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.3.2.2.3 Effects of Vibration and Thermal Cycling on Fuel Assemblies Analyses of the effect of cyclic deflection of the fuel rods, grid spring, rod cluster control rods, and burnable absorber rods due to hydraulically induced vibrations and thermal cycling show that the design of the components is good for an infinite number of cycles.

In the case of the fuel rod grid spring support, the amplitude of a hydraulically induced motion of the fuel rod is extremely small (approximately 0.001-in.), and the stress associated with the motion is significantly small (<100 psi). Likewise, the reactions at the grid spring due to the motion is much less than the preload spring force and contact is maintained between the fuel clad and the grid spring and dimples. Fatigue of the clad and fretting between the clad and the grid support is not anticipated.

The effect of thermal cycling on the grid-clad support is a slight relative movement between the grid contact surfaces and the clad. Since the number of cycles of the occurrence is small over the life of a fuel assembly (approximately 3 years), negligible wear of the mating parts is expected. Incore operation of assemblies in the Yankee Rowe and Saxton reactors using similar clad support have verified the calculated conclusions. Additional test results under simulated reactor environment in the Westinghouse Reactor Evaluation Channel also support these conclusions.

The dynamic deflection of the control rods and the burnable absorber rods is limited by their fit with the inside diameter of either the upper portion of the guide thimble or the dashpot. With this limitation, the occurrence of truly cyclic motion is questionable. However, an assumed cyclic deflection through the available clearance gap results in an insignificantly low stress in either the clad tubing or in the flexure joint at the spider or retainer plate. The above consideration assumes the rods are supported as cantilevers from the spider or the retainer plate in the case of the burnable absorber rods.

A calculation assuming the rods are supported by the surface of the dashpots and at the upper end by the spider or retainer results in a similar conclusion.

3.2.3.3 Transition Cores The entire core is now 15x15 Upgraded fuel therefore there are no transition core effects.

3.2.3.4 Control Rod Drive Mechanism Design Description 3.2.3.4.1 Full Length Rods The control rod drive mechanisms are used for withdrawal and insertion of the rod cluster control assemblies into the reactor core and to provide sufficient holding power for stationary support.

Fast total insertion (reactor trip) is obtained by simply removing the electrical power allowing the rods to fall by gravity. Design scram time is 2.4 seconds from gripper release to dashpot entry.

The complete drive mechanism, shown in Figure 3.2-65, consists of the internal (latch) assembly, the pressure vessel, the operating coil stack, the drive shaft assembly, and the rod position indicator coil stack.

Chapter 3, Page 53 of 94 Revision 25, 2014

IP2 FSAR UPDATE Each assembly is an independent unit, which can be dismantled or assembled separately.

Each mechanism pressure housing is threaded onto an adaptor on top of the reactor pressure vessel and seal welded. The operating drive assembly is connected to the control rod (directly below) by means of a grooved drive shaft. The upper section of the drive shaft is suspended from the working components of the drive mechanism. The drive shaft and control rod remain connected during reactor operation including tripping of the rods.

Main coolant fills the pressure containing parts of the drive mechanism. All working components and the shaft are immersed in the main coolant and depend upon it for lubrication of sliding parts.

Three magnetic coils, which form a removable electrical unit and surround the rod drive pressure housing, induce magnetic flux through the housing wall to operate the working components. They move two sets of latches, which lift, lower, and hold the grooved drive shaft.

The three magnets are turned on and off in a fixed sequence by solid-state switches for the full length rod assemblies.

The sequencing of the magnets produces step motion over the full length of normal control rod travel.

The mechanism develops a lifting force approximately two times the static lifting load.

Therefore, extra lift capacity is available for overcoming mechanical friction between the moving and the stationary parts. Gravity provides the drive force for rod insertion and the weight of the whole rod assembly is available to overcome any resistance.

The mechanisms are designed to operate in water at 650°F and 2485 psig. The temperature at the mechanism head adaptor will be much less than 650°F because it is located in a region where there is limited flow of water from the reactor core while the pressure is the same as in the reactor pressure vessel. A multiconductor cable connects the mechanism operating coils to the 125-V DC power supply. The power supply is described in Section 7.3.2.

3.2.3.4.1.1 Latch Assembly The latch assembly contains the working components, which withdraw and insert the drive shaft and attached control rod. It is located within the pressure housing and consists of the pole pieces for three electromagnets. They actuate two sets of latches, which engage the grooved section of the drive shaft.

The upper set of latches move up or down to raise or lower the drive rod by 5/8-in. The lower set of latches have a 1/16-in. axial movement to shift the weight of the control rod from the upper to the lower latches.

3.2.3.4.1.2 Pressure Vessel The pressure vessel consists of the pressure housing and rod travel housing. The pressure housing is the lower portion of the vessel and contains the latch assembly. The rod travel housing is the upper portion of the vessel. It provides space for the drive shaft during its upward movement as the control rod is withdrawn from the core.

Chapter 3, Page 54 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.3.4.1.3 Operating Coil Stack The operating coil stack is an independent unit, which is installed on the drive mechanism by sliding it over the outside of the pressure housing. It rests on a pressure housing flange without any mechanical attachment and can be removed and installed while the reactor is pressurized.

The three operating coils are made of round copper wire, which is insulated with a double layer of filament type glass yarn.

The design operating temperature of the coils is 200°C. Average coil temperature can be determined by resistance measurement. Forced air cooling along the outside of the coil stack maintains a coil casing temperature of approximately 120°C or lower.

3.2.3.4.1.4 Drive Shaft (Drive Rod) Assembly The main function of the drive shaft is to connect the control rod to the mechanism latches.

Grooves for engagement and lifting by the latches are located throughout the 144-in. of control rod travel. The grooves are spaced 5/8-in. apart to coincide with the mechanism step length and have 45-degree-angle sides.

The drive shaft is attached to the control rod by the coupling. The coupling has two flexible arms, which engage the grooves in the spider assembly.

A 0.25-in. diameter disconnect rod runs down the inside of the drive shaft. It uses a locking button at its lower end to lock the drive rod assembly and control rod assembly together. At its upper end there is a disconnect assembly for remote disconnection of the drive rod assembly from the control rod assembly.

During plant operation, the drive shaft assembly remains connected to the control rod at all times. It can be attached and removed from the control rod only when the reactor vessel head is removed.

3.2.3.4.1.5 Position Indicator Coil Stack The position indicator coil stack slides over the rod travel housing section of the pressure vessel. It detects drive rod position by means of a cylindrically wound differential transformer, which spans the normal length of the rod travel (144-in.).

3.2.3.4.1.6 Drive Mechanism Materials All parts exposed to reactor coolant, such as the pressure vessel, latch assembly, and drive rod, are made of metals, which resist the corrosive action of the water.

Three types of metals are used exclusively: stainless steels, Inconel-X, and cobalt-based alloys. Wherever magnetic flux is carried by parts exposed to the main coolant, 400 series stainless steel is used. Cobalt-based alloys are used for the pins, latch tips, and bearing surfaces.

Inconel-X is used for the springs of both latch assemblies and type 304 stainless steel is used for all pressure containment. Hard chrome plating provides wear surfaces on the sliding parts and prevents galling between matting parts (such as threads) during assembly.

Chapter 3, Page 55 of 94 Revision 25, 2014

IP2 FSAR UPDATE Outside of the pressure vessel, where the metals are exposed only to the reactor containment environment and cannot contaminate the main coolant, carbon and stainless steels are used.

Carbon steel, because of its high permeability, is used for flux return paths around the operating coils. It is zinc-plated approximately 0.001-in. thick to prevent corrosion.

3.2.3.4.1.7 Principles of Operation The drive mechanisms, shown schematically in Figure 3.2-66, withdraw and insert their respective control rods as electrical pulses are received by the operator coils.

ON and OFF sequence, repeated by switches in the power programmer, causes either withdrawal or insertion of the control rod. Position of the control rod is indicated by the transformer action of the position indicator coil stack surrounding the rod travel housing. The transformer output changes as the top of the ferromagnetic drive shaft assembly moves up the rod travel housing. Generally during plant operation the drive mechanisms hold the control rods withdrawn from the core in a static position and only one coil, the stationary gripper coil, is energized on each mechanism.

Control Rod Withdrawal The control rod is withdrawn by repeating the following sequence:

1. Movable Gripper Coil - ON The movable gripper armature raises and swings the movable gripper latches into the drive shaft groove.
2. Stationary Gripper Coil - OFF Gravity causes the stationary gripper latches and armature to move downward until the load of the drive shaft is transferred to the movable gripper latches.

Simultaneously, the stationary gripper latches swing out of the shaft groove.

3. Lift Coil - ON The 5/8-in. gap between the lift armature and the lift magnet pole closes and the drive rod raises one step length.
4. Stationary Gripper Coil - ON The stationary gripper armature raises and closes the gap below the stationary gripper magnetic pole, swings the stationary gripper latches into a drive shaft groove. The latches contact the shaft and lift it 1/16-in. The load is so transferred from the movable to the stationary gripper latches.
5. Movable Gripper Coil - OFF The movable gripper armature separates from the lift armature under the force of three springs and gravity. Three links, pinned to the movable gripper armature, swing the three movable gripper latches out of the groove.

Chapter 3, Page 56 of 94 Revision 25, 2014

IP2 FSAR UPDATE

6. Lift Coil - OFF The gap between the lift armature and the lift magnet pole opens. The movable gripper latches drop 5/8-in. to a position adjacent to the next groove.

Control Rod Insertion The sequence for control rod insertion is similar to that for control rod withdrawal:

1. Lift Coil - ON The movable gripper latches are raised to a position adjacent to a shaft groove.
2. Movable Gripper Coil - ON The movable gripper armature raises and swings the movable gripper latches into a groove.
3. Stationary Gripper Coil - OFF The stationary gripper armature moves downward and swings the stationary gripper latches out of the groove.
4. Lift Coil - OFF Gravity separates the lift armature from the lift magnet pole and the control rod drops down 5/8-in.
5. Stationary Gripper Coil - ON
6. Movable Gripper Coil - OFF The sequences described above are termed as one step or one cycle and the control rod moves 5/8-in. for each cycle. Each sequence can be repeated at a rate of up to 72 steps/min and the control rods can therefore be withdrawn or inserted at a rate of up to 45-in./min. The sequence timing has been modified to preclude the rod withdrawal event described in NRC Generic Letter 93-04.

Control Rod Tripping If power to the movable gripper coil is cut off, as for tripping, the combined weight of the drive shaft and the rod cluster control assembly is sufficient to move the latches out of the shaft groove. The control rod falls by gravity into the core. The tripping occurs as the magnetic field, holding the movable gripper armature against the lift magnet, collapses and the movable gripper armature is forced down by the weight acting upon the latches.

3.2.3.4.2 Part-Length Rods

[Deleted]

Chapter 3, Page 57 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2.3.5 Fuel Assembly and Rod Cluster Control Assembly Mechanical Evaluation To confirm the mechanical adequacy of the fuel assembly and full length rod cluster control assembly, functional test programs have been conducted on a full scale Indian Point Unit 2 prototype 12-ft canless fuel assembly and control rod. The prototype assembly was tested under simulated conditions of reactor temperature, pressure, and flow for approximately 1000 hr. The prototype mechanism accumulated 2,260,892 steps and 600 scrams. At the end of the test the control rod drive mechanism was still operating satisfactorily. A correlation was developed to predict the amplitude of flow excited vibration of individual fuel rods and fuel assemblies. Inspection of the fuel assembly and drive line components did not reveal significant fretting. The wear of the absorber rods, fuel assembly guide thimbles, and upper guide tubes was minimal. The control rod free fall time against 125-percent of nominal flow was less than 1.5 sec to the dashpot (10-ft of travel). Additional tests had previously been made on a full scale San Onofre mockup version of the fuel assembly and control rods (Reference 73).

3.2.3.5.1 One-Seventh Scale Mockup Tests A one-seventh scale model of the Indian Point Unit 2 internals was designed and built for hydraulic and mechanical testing. The tests provided information on stresses and displacements at selected locations on the structure due to static loads, flow induced loads, and electromagnetic shaker loads. Flow distribution and pressure drop information were obtained.

Results of the static tests indicated that mean strains in the upper core support plate and upper support columns are below design limits. Strains and displacements measured in the model during flow tests verified that no damaging vibration levels were present. Additional information gained from the tests was the natural frequency and damping of the thermal shield and other components in air and water. Model response can be related to the full scale plant for most of the expected exciting phenomena, but across-the-board scaling is not possible. Specifically exciting phenomena, which are strongly dependent on Reynolds number cannot be scaled. In areas where Reynolds number may be important, either (1) the measured vibration amplitudes were many times lower than a level that would be damaging, or (2) full scale vibration data have been obtained.

3.2.3.5.2 Loading and Handling Tests Tests simulating the loading of the prototype fuel assembly into a core location have also been successfully conducted to determine that proper provisions had been made for guidance of the fuel assembly during refueling operation.

3.2.3.5.3 Axial and Lateral Bending Tests Axial and lateral bending tests have been performed in order to simulate mechanical loading of the assembly during refueling operation. Although the maximum column load expected to be experienced in service is approximately 1000 lb, the fuel assembly was successfully loaded to 2200 lb axially with no damage resulting. This information is also used in the design of fuel handling equipment to establish the limits for inadvertent axial loads during refueling.

3.2.4 Fixed Incore Detectors Eight fixed core neutron detectors are installed within the Unit 2 reactor as shown in Figure 3.2-

67. They provide no input to plant instrumentation nor are they needed by the operator. The detectors have been retired and are cut and capped at the seal table.

Chapter 3, Page 58 of 94 Revision 25, 2014

IP2 FSAR UPDATE The detectors are not movable when the primary system is at operating pressure. The assemblies are extracted downward from the core during refueling. The seal table used for the movable detector assemblies is also utilized for the fixed incore detector assemblies.

The installation of the fixed incore detector system is expected to cause no significant reactivity effect. If a fixed detector were to fail, the expulsion of reactor coolant would be accommodated by the charging pumps, which is common for ruptures of a very small cross section. This would enable the operator to execute an orderly shutdown. If a seal were to fail at the seal table, flow from the reactor coolant system would be through the annulus defined by the O.D. of the flux thimble and the I.D. of the conduit (approximately 0.13-in.). The fixed incore detector system is designed to Class I standards such that the likelihood of a failure causing a loss of coolant will be extremely remote.

3.2.4.1 Core Monitoring Verification of axial and radial power distribution during full power operation is performed using the movable incore detector system. These movable detector locations are shown in Figure 3.2-68. The axial power distribution during operation is determined for each measured thimble location since the activity level is measured at several axial heights for each thimble.

Comparison of the measured power distribution to design predictions provides confirmation of safe operation of the reactor and confidence in design predictions. To obtain temperature maps of the core, 65 fuel assembly outlet thermocouples are located as shown in Figure 3.2-68.

These thermocouples are located in the upper coolant internals package above the corresponding assemblies. Based on the average activity determined for each thimble, the measured radial power distribution can be determined.

3.2.5 Plant Computer The computer system provided for Indian Point Unit 2 is a DS&S Plant Integrated Computer System known as PICS. It is provided as an adjunct to the normal control room instrumentation to assist the operator in the operation of the reactor by monitoring reactor performance and displaying it in a consistent, well-ordered, usable form. The computer system performs functions such as scanning, signal converting, calculating, indicating, recording, and alarm annunciating. This system is not required for safety, and operation of the reactor is not in any way dependent upon the availability of the computer.

Briefly, the analog scanning includes reading all inputs in a pre-established manner, checking the readings, converting values to engineering units, storing them for future use, updating information, and checking alarm conditions. Some inputs are scanned once every second and status placed in memory; other inputs are not scanned periodically but are given immediate attention. The alarm program compares the values of the inputs against the fixed or variable alarm limits and indicates when off-normal conditions exist. The system has a data diode for cyber security purposes between the level 3 and level 2 networks.

3.2.6 Current Operating Cycle Indian Point Unit 2 is currently operating in the twenty-second cycle. The core for this cycle uses 15x15 Upgraded fuel. In order to reduce neutron fluence to the reactor vessel shell, a low-low leakage loading pattern, shown in Figure 3.2-68A, is utilized. Integrated fuel burnable absorbers (IFBA) and wet annular burnable absorber (WABA) assemblies, described in References 74 and 88, are used. Figures 3.2-68 and 3.2-68B show the locations of core components and instrumentation. The cycle is designed for a burnup of 25,103 MWd/MTU Chapter 3, Page 59 of 94 Revision 25, 2014

IP2 FSAR UPDATE which includes a power coastdown. The methodology and computer codes described in References 75, 82, [Deleted], 96, 97, and 102 were utilized for analysis of the current operating cycle. Fuel temperatures were calculated using the fuel thermal models of References 69 and 84 (prior to Cycle 16 the analysis was done with Reference 83).

Beginning with Cycle 11, replacement fuel has debris filter bottom nozzles and integral fuel burnable absorbers. To prevent debris from reaching the core, the nozzles have a larger number of smaller holes than previous designs. The integral fuel burnable absorber (IFBA) fuel has a thin layer of zirconium diboride or enriched zirconium diboride coated directly onto selected fuel pellets to control power peaking.

A three dimensional model is used to track and predict core operating characteristics. The code predictions are compared to startup physics test results, measured core flux distributions, and critical boron concentrations as a function of core burnup. It has been shown to provide a suitable and accurate means for predicting core operating conditions.

REFERENCES FOR SECTION 3.2

1. Westinghouse Electric Corporation, "Power Distribution Control in Westinghouse Pressurized Water Reactors," WCAP-7208 (Proprietary), 1968.
2. R. F. Barry, et al., "Power Maldistribution Investigations," WCAP-7407-L (Proprietary), Westinghouse Electric Corporation.
3. F. B. Skogen and A. F. McFarlane, "Xenon-Induced Spatial Instabilities in Three-Dimensions," WCAP-3680-22, Westinghouse Electric Corporation, September 1969.
4. T. Morita, et al., "Power Distribution Control and Load Following Procedures,"

WCAP-8385 (Proprietary), September 1974 and WCAP-8403 (Non-Proprietary),

Westinghouse Electric Corporation, September 1974.

5. F. L. Langford and R. J. Nath, "Evaluation of Nuclear Hot Channel Factor Uncertainties," WCAP-7308-L (Proprietary), April 1969 and WCAP-7810 (Non-Proprietary), Westinghouse Electric Corporation, December 1971.
6. J. M. Hellman, (Ed), "Fuel Densification Experimental Results and Model for Reactor Application," WCAP-8218-P-A (Proprietary), Westinghouse Electric Corporation, March 1975 and WCAP-8219-A (Non-Proprietary),March 1975.
7. R. O. Meyer, "The Analysis of Fuel Densification," Division of Systems Safety, NUREG-0085, U.S. Nuclear Regulatory Commission, July 1976.
8. J. M. Hellman, C. A. Olson, and J. M. Yang, "Effects of Fuel Densification Power Spikes on Clad Thermal Transients," WCAP-8359, Westinghouse Electric Corporation, July 1974.
9. "Power Distribution Control of Westinghouse Pressurized Water Reactors,"

WCAP-7811 (Non-Proprietary), Westinghouse Electric Corporation, December 1971.

Chapter 3, Page 60 of 94 Revision 25, 2014

IP2 FSAR UPDATE

10. R. J. Johnson, "Connecticut-Yankee Tests on Detection of Power Maldistribution," WCAP-9010 (Proprietary), Westinghouse Electric Corporation, February 1969.
11. P. M. Wood, E. A. Bassler, et al., "Use of Burnable Poison Rods in Westinghouse Pressurized Water Resources," WCAP-7113, Westinghouse Electric Corporation, October 1967.
12. R. F. Barry, "The Revised LEOPARD Code - A Spectrum Dependent Non-Spatial Depletion Program," WCAP-2759, Westinghouse Electric Corporation, March 1965.
13. VANTAGE+ Fuel Upgrade Reload Transition Safety Report for Indian Point Unit 2, September 1994.
14. Kersting, P.J. et al., Assessment of Clad Flattening and Densification Power Spike Factor Elimination in Westinghouse Nuclear Fuel, WCAP-13589-A, March 1995.
15. Davidson, S.L. (Ed.) et al., Extended Burnup Evaluation of Westinghouse Fuel, WCAP-10125-P-A, December 1985.
16. Davidson, S.L (Editor), Westinghouse Fuel Criteria Evaluation Process, WCAP-12488-A, October 1994.
17. Letter from N.J Liparulo (Westinghouse) to R.J. Jones (NRC) Westinghouse Interpretation of Staffs Position on Extended Burnup (Proprietary), NTD-NRC-94-4275, August 29,1994.
18. Deleted
19. Deleted
20. Deleted
21. Deleted
22. Deleted
23. Deleted
24. Deleted
25. R.A. Dean, "Thermal Contact Conductance Between UO2 and Zircaloy-2,"CVNA-127, May 1962.
26. A.M. Ross and R.D. Stoute, "Heat Transfer Coefficient Between UO2 and Zircaloy-2," AECL-1552, June 1962.
27. V.C. Howard and T.G. Gulivin, "Thermal Conductivity Determinations on Uranium Dioxide by a Radial Flow Method", UKAEA IG-Report 51, November1960.

Chapter 3, Page 61 of 94 Revision 25, 2014

IP2 FSAR UPDATE

28. C.F. Lucks and H.W. Deem, Thermal conductivity and Electrical Conductivity of UO2 in Progress Reports Relating to Civilian Applications, BMI-1448 (Rev) (June 1960); BMI-1489 (Rev.) (December, 1960) and BMI-1518 (Rev.) Battelle Memorial Institute-Columbus (May, 1961).
29. J. L. Daniel, J. Matolich, Jr., and H.W. Deem, "Thermal Conductivity of UO2,"

HW-69945, September 1962.

30. A. D. Feith, "Thermal Conductivity of UO2 by a Radial Heat Flow
31. J. Vogt, L. Grandell, and U. Runfors, "Determination of the Thermal Conductivity of Unirradiated Uranium Dioxide," AB Atomenergi Report RMB-527, 1964, Quoted by IAEA Technical Report Series No. 59, "Thermal Conductivity of Uranium Dioxide."
32. T. Nishijima, T. Kawada, and A. Ishihata, "Thermal Conductivity of Sintered UO2 and AI2O3 at High Temperatures," J. American Ceramic Society, Vol. 48, pp. 31-34, 1965.
33. J. B. Ainscough and M.H. Wheeler, "Thermal Diffusivity and Thermal Conductivity of Sintered Uranium Dioxide," in Proceedings of the Seventh Conference of Thermal Conductivity, p. 467, National Bureau of Standards, Washington, 1968.
34. T. G. Godfrey, et al., "Thermal Conductivity of Uranium Dioxide Armco Iron by and Improved Radial Heat Flow Technique," ORNL-3556, June 1964.
35. J. P. Stora, et al., "Thermal Conductivity of Sintered Uranium Oxide Under In-Pile Conditions," EURAEC-1095, August 1964.
36. A. J. Bush, "Apparatus for Measuring Thermal Conductivity to 2500°C," Report 64-1P6-401-43 (Proprietary), Westinghouse Research Laboratories, February 1965.
37. R. R. Asamoto, F.L. Anselin, and A.E. Conti, "The Effect of Density on the Thermal Conductivity of Uranium Dioxide," GEAP-5493, April 1968.
38. O. L. Kruger, "Heat Transfer Properties of Uranium and Plutonium Dioxide,"

Paper 11-N-68F presented at the Fall Meeting of Nuclear Division of the American Ceramic Society, Pittsburgh, Pa., September 1968

39. J. A. Gyllander, "In-Pile Determination of the Thermal Conductivity of UO2 in the Range 500-2500°C," AE-411, January 1971.
40. M. F. Lyons, et al., "UO2 Powder and Pellet Thermal Conductivity During Irradiation," GEAP-5100-1, March 1966.
41. R. N. Duncan, "Rabbitt Irradiation of UO2" CVNA-142, June 1962.

Chapter 3, Page 62 of 94 Revision 25, 2014

IP2 FSAR UPDATE

42. A. S. Bain, "The Heat Rating Required to Produce Center Melting in Various UO2 Fuels," ASTM Special Technical Publication No. 306, pp. 30-46, Philadelphia, Pa., 1962.
43. J. P. Storal, "In-Reactor Measurements of the Integrated Thermal Conductivity of UO2 - Effect of Porosity," Trans. ANS, Vol. 13, 137-138, 1970
44. International Atomic Energy Agency, "Thermal Conductivity of Uranium Dioxide,"

Report of the Panel held in Vienna, April 1965, IAEA Technical Reports Series No. 59, Vienna, The Agency, 1966.

45. J. A. Christensen, R.J. Allio, and A. Biancheria, "Melting Point of Irradiated Uranium Dioxide," WCAP-6065, Westinghouse Electric Corporation, February 1965.
46. W. R. Smalley, "Survey of Experience With High Performance Fuel Rods of PWR Type, WCAP-7125, Westinghouse Electric Corporation, January 1968.
47. L. S. Tong, "Prediction of Departure From Nucleate Boiling for an Axially Non-Uniform Heat Flux Distribution," Journal of Nuclear Energy, Vol. 21, pp. 241-248, 1967.
48. L. S. Tong, H. B. Currin, and A.G. Throp II, "New Correlations Predict DNB Conditions," Nucleonics, May 1963. Also WCAP-1997, 1963.
49. L. S. Tong, "Boiling Crisis and Critical Heat Flux," AEC Critical Review Series, TID-25887, 1972.
50. F. E. Motely and F. F. Cadek, "Application of Modified Spacer Factor to L-Grid Typical and Cold Wall Cell DNB," WCAP-8030-A (Non-Proprietary),Westinghouse Electric Corporation, October, 1972.
51. L. S. Tong, R. P. Sandberg, and A.A. Bishop, "Forced Convection Heat Transfer at High Pressure After the Critical Heat Flux," ASME 65-HT-31 1965.
52. K. W. Hill, F. E. Motley, and F.F. Cadek, "Effect of Local Heat Flux Spikes on DNB in Non-Uniform Heated Rod Bundles," WCAP-8174 (Proprietary), August 1973, and WCAP-8202 (Non-Proprietary), Westinghouse Electric Corporation, August 1973.
53. G. Hetsroni, "Hydraulic Tests of the San Onofre Reactor Model, WCAP-3269-8, June 1964.
54. G. Hetsroni, "Studies of the Connecticut-Yankee Hydraulic Model," NYO-3250-2, June 1965.
55. F. D. Carter, "Inlet Orificing of Open PWR Cores," WCAP-7836, Westinghouse Electric Corporation, January 1972.
56. J. Shefcheck, "Application of the THINC Program to PWR Design," WCAP-7359-L (Proprietary), August 1969, and WCAP-7838 (Non-Proprietary), Westinghouse Electric Corporation, January 1972.

Chapter 3, Page 63 of 94 Revision 25, 2014

IP2 FSAR UPDATE

57. F. F. Cadek, "Interchannel Thermal Mixing With Mixing Vane Grids," WCAP-7667-P-A (Proprietary) and WCAP-7755-A (Non-Proprietary), Westinghouse Electric Corporation, January 1975.
58. I.E. Idel'chik, "Handbook of Hydraulic Resistance," AEC-TR-6630, 1960.
59. L.F. Moody, "Friction Factors for Pipe Flow, "Transaction of the American Society of Mechanical Engineers, Vol. 66, pp. 671-684, 1944.
60. J. Weisman, A. H. Wenzel, L. S. Tong, D. Fitzsimmons, W. Thorne, and J. Batch, "Experimental Determination of the Departure From Nucleate Boiling In Large Rod Bundles at High Pressure," AICHE, Preprint 29, 9th National Heat Transfer Conference, Seattle, Washington, 1967.
61. L. S. Tong, H. Chelemer, J. E. Casterline, and B. Matzner, "Critical Heat Flux (DNB) in Square and Triangular Array Rod Bundles," JSME, Semi-International Symposium, Paper No. 256, Tokyo, Japan, 1967.
62. Deleted
63. Deleted
64. Deleted
65. Deleted
66. Deleted
67. Deleted
68. J. V. Miller (Ed), "Improved Analytical Models Used in Westinghouse Fuel Rod Design Computations," WCAP-8785, Westinghouse Electric Corporation, October 1976.
69. R. A. Weiner, et al., "Improved Fuel Performance Models for Westinghouse Fuel Rod Design and Safety Evaluations," WCAP-11873-A, Westinghouse Electric Corporation, August 1988.
70. "Fuel Densification--Indian Point Nuclear Generating Station Unit No.2," WCAP-8062, Westinghouse Electric Corporation, January 1973.
71. "Addendum to Densification - Indian Point Nuclear Generating Station Unit No.

2," WCAP-8062-Addendum, Westinghouse Electric Corporation, dated March 22, 1973.

72. Deleted
73. Westinghouse Electric Corporation, "Large Closed Cycle Water Reactor Research and Development Program Quarterly Progress Reports for the Period January 1963 through June 1965, "WCAP-3738, 3739, 3743, 3750, 3269-2, 3269-5, 3269-6, 3269-12 and 3269-13.

Chapter 3, Page 64 of 94 Revision 25, 2014

IP2 FSAR UPDATE

74. Westinghouse Electric Corporation, "Westinghouse Wet Annular Burnable Absorber Evaluation Report," WCAP-10021-P-A, Rev.1 (Proprietary), October 1983.
75. Davidson, S. L. (Ed), et al, "Westinghouse Reload Safety Evaluation Methodology," WCAP-9273-NP-A, Westinghouse Electric Corporation, July 1985.
76. Motley, F. E., Hill, K. W., Cadek, F. F. and Shefcheck, J., "New Westinghouse Correlation WRB-1 for Predicting Critical Heat Flux in Rod Bundles with Mixing Vane Grids," WCAP-8762-P-A, July 1984 (Proprietary) and WCAP-8763, July 1976 and July 1985.
77. H. Chelemer, et al, "THINCIV-An Improved Program for Thermal-Hydraulic Analysis of Rod Bundle Cores," WCAP-7956, June 1973.
78. Hochreiter, L. E., et al, "Application of THINCIV Program to PWR Design,"

WCAP-8054, September 1973.

79. Chelemer, H., et al, "Improved Thermal Design Procedure," WCAP-8567, July 1975.
80. Skaritka, J., et al, "Fuel Rod Bow Evaluation," WCAP-8691, Rev. 1 (Proprietary),

WCAP-8692, Rev. 1 (non-Proprietary) July 1979.

81. Letter from C. Berlinger (NRC) to E. P. Rahe, Jr. (Westinghouse), "Request for Reduction in Fuel Assembly Burn-Up Limit for Calculation of Maximum Rod Bow Penalty," June 18, 1986.
82. Liu, Y. S., et al, "ANC: A Westinghouse Advanced Nodal Computer Code,"

WCAP-10965-P-A and WCAP-10966-A, September 1986.

83. Leech, W. J., et al, "Revised PAD Code Thermal Safety Model," WCAP-8720 Addendum 2 (Proprietary), October 1982.
84. Slage, W.H. (Ed.), Westinghouse Improved Performance Analysis and Design Model (PAD 4.0), WCAP-15063-P-A, Rev.1 w/errata July 2000.

84a. Gergos, B. W. and Slagle W. H., "Reload Safety Evaluation Indian Point Nuclear Plant Unit 2 Cycle 11", Attachment to THFL-91-371, Westinghouse Electric Corporation, June 1991.

85. MD2-04-25, 15x15 Upgrade Fuel Assembly - Design Closeout Package (DR02-3), 5/24/04.
86. Chelemer, H., et al, "Improved Thermal Design Procedure," WCAP-8568-A February 1989.
87. Deleted 87a. Davidson, S. L., "Reference Core Report VANTAGE 5 Fuel Assembly," WCAP-10444, Addendum 1, December 1985, WCAP-10445-NP-A, September 1985.

Chapter 3, Page 65 of 94 Revision 25, 2014

IP2 FSAR UPDATE

88. Davidson, S. L., Nuhfer, D. L. (Eds), "VANTAGE+ Fuel Assembly Reference Core Report", WCAP-12610-P-A and Appendices A through G, April, 1995.
89. Letter from A. C. Thadani (NRC) to W. J. Johnson (Westinghouse), January 31, 1989,

Subject:

Acceptance for Referencing of Licensing Topical Report, WCAP-9226-P/9227-NP, "Reactor Core Response to Excessive Secondary Steam Releases."

90. Davidson, S. L., Iorii, J. A., "Reference Core Report - 17x17 Optimized Fuel Assembly," WCAP-9500-A, May 1982.
91. Letter from E. P. Rahe (Westinghouse) to J. R. Miller (NRC), "WCAP-9500 and WCAP-9401/9402 NRC SER Mixed Core Compatibility Items," NS-EPR-2573, March 19, 1982.
92. Schueren, P. and McAtee, K. R., "Extension of Methodology for Calculating Transition Core DNBR Penalties," WCAP-11837-P-A, January 1990.
93. Letter from C. O. Thomas (NRC) to E. P. Rahe (Westinghouse), "Supplemental Acceptance No. 2 for Referencing Topical Report WCAP-9500," January 1983.
94. Letter from A. C. Thadani (NRC) to W. J. Johnson (Westinghouse), "Acceptance for Referencing of Licensing Topical Report WCAP-11837", October 1989.
95. Tong L. S., Critical Heat Flux in Rod Bundles, Two Phase Flow and Heat Transfer in Rod Bundles," Annual Winter Meeting ASME, November 1968, Page 3146.
96. Friedland, A. J. and Ray, S. "Improved THINC-IV Modeling for PWR Core Design", WCAP-12330-P, August 1989.
97. Friedland, A. J. and Ray, S. "Revised Thermal Design Procedure", WCAP 11397-P-A, April 1989.
98. Slagle, W.H., "Westinghouse Fuel Assembly Reconstitution Evaluation Methodology," WCAP-13061-NP-A, July 1993.
99. "ARMP-02 Documentations: Part II, Chapter 11 - NODE-P2 Computer Code Manuals, Vol. I and II," EPRI NP-4574-CCM, Electric Power Research Institute, Palo Alto, CA, October 1988.

100. Stewart, C.W. et al., VIPRE-01: A Thermal-Hydraulic Code for Reactor Cores.

Volumes 1-3 (Revision 3, August 1989) Volume 4 (April 1987), NP-2511-CCM-A, Electric Power Research Institute.

101. WCAP-14565-P-A/WCAP-15306-NP-A, VIPRE-01 Modeling and Qualification for Pressurized Water Reactor Non-LOCA Thermal-Hydraulic Safety Analysis, October 1999, Sung, Y. et al.

102. WCAP-16045-P-A, Qualification of the Two-Dimensional Transport Code PARAGON, August 2004, Slagle, W.H., et. al.

Chapter 3, Page 66 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-1 (Sheet 1 of 3)

Nuclear Design Data Cycle 1 Values STRUCTURAL CHARACTERISTICS

1. Fuel weight (UO2), lbs 217,800
2. Zircaloy weight, lbs 44,600
3. Core diameter, in. 132.75
4. Core height, in.

Reflector thickness and composition 144

5. Top water plus steel, in. ~ 10
6. Bottom water plus steel, in. ~ 10
7. Side water plus steel, in. ~ 15
8. H2O/U, (cold) core 3.91
9. Number of fuel assemblies 193
10. UO2 rods per assembly 204 PERFORMANCE CHARACTERISTICS
11. Heat output, MWt (initial rating) 2758
12. Heat output, MWt (maximum calculated turbine rating) 3216
13. Fuel burnup, MWd/metric ton uranium 16,100 First cycle enrichments, w/o
14. Region 1 2.21
15. Region 2 2.80
16. Region 3 3.20
17. Equilibrium enrichment 3.2
18. Nuclear heat flux hot channel factor, F T Q 1 2.32
19. Nuclear enthalpy rise hot channel factor, F N H

1.55 Chapter 3, Page 67 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-1 (Sheet 2 of 3)

Nuclear Design Data Cycle 1 Values CONTROL CHARACTERISTICS Effective multiplication (Beginning-of-Life) with rods in, no Boron

20. Cold, no power, clean 1.113
21. Hot, no power, clean 1.057
22. Hot, full power, clean 1.031
23. Hot, full power, Xe and Sm equilibrium 1.001
24. Material 5-percent Cd; 15-percent In; 80-percent Ag
25. Full length rod cluster control assemblies, number 53
26. Part length rod cluster control assemblies (removed)
27. Number of absorber rods per rod cluster control assemblies 7,8,9,12,16, or 20
28. Total rod worth, BOL, percent (See Table 3.2-2)

Boron concentration for first core cycle loading with burnable poison rods

29. Fuel loading shutdown; rods in (k = .86) 2000 ppm (k = .90) 1615 ppm
30. Shutdown (k = .99) with rods inserted, clean, cold 849 ppm
31. Shutdown (k = .99) with rods inserted, clean, hot 572 ppm
32. Shutdown (k = .99) with no rods inserted, clean, hot 1405 ppm
33. Shutdown (k = .99) with no rods inserted, clean, cold 1370 ppm Chapter 3, Page 68 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-1 (Sheet 3 of 3)

Nuclear Design Data Cycle 1 Values Boron concentration to maintain k = 1 at hot full power, No rods inserted:

34. Clean 1160 ppm
35. Xenon 860 ppm
36. Xenon and Samarium 780 ppm
37. Shutdown, all but one rod inserted, clean, cold (k = .99) 915 ppm
38. Shutdown, all but one rod inserted, clean, hot (k = .99) 677 ppm BURNABLE POISON RODS
39. Number and material 1412 Borated Pyrex Glass
40. Worth hot p 8.2-percent
41. Worth cold p 5.4-percent KINETIC CHARACTERISTICS
42. Moderator temperature coefficient at fuel power (°F-1) - 0.25 x 10-4 to

- 3.00 x 10-4

43. Moderator pressure coefficient (psi-1) + 0.2 x 10-6 to

+ 3.00 x 10-6

44. Moderator density coefficient, delta k/gm/cm3 - 0.1 to .30
45. Doppler coefficient (°F-1) - 1.1 x 10-5 to 1.8 x 10-5
46. Delayed neutron fraction, percent 0.50 to .72
47. Prompt neutron lifetime, sec 1.50 x 10-5 to 2.0 x 10-5 Note:
1. The total flux hot channel factor (F QT ) is a generic limit.

The actual value is presented in the Technical Specifications.

Chapter 3, Page 69 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-1A Nuclear Design Data Cycle 22 Values

1. Heat output, MWt 3216
2. Fuel loading shutdown boron concentration; rods in >2050 (k 0.95)
3. Most positive Moderator Temperature Coefficient -9.93 (pcm/°F)
4. Least Negative Doppler- Only Power Coefficient, Zero to Full -13.18 to -8.51 Power (pcm/% Power)
5. Most Negative Doppler- Only Power Coefficient, Zero to Full -14.69 to -8.95 Power (pcm/% Power)
6. Effective average delayed 0.510 to 0.621 neutron fraction Beff, percent
7. Prompt neutron lifetime, sec 11.66 to 14.26
8. Design bases minimum 1.3 shutdown (% p)
9. Nuclear Heat Flux Hot Channel 2.3 Factor (Fq) limit
10. Nuclear Enthalpy Rise Hot 1.65 Channel Factor (FdH) limit Chapter 3, Page 70 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-2 Reactivity Requirements for Control Rods for Cycle 11 Percent Requirements Beginning-of-Life End-of-Life Control Power defect 1.90 3.05 Operational maneuvering band 0.40 0.40 Control rod bite 0.10 0.10 X-Y xenon rods 0.20 0.20 Total control 2.60 3.75 Notes:

1. Design values used for performing preoperational calculations and analyses.

Chapter 3, Page 71 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-3 Calculated Rod Worths, for Cycle 1 Design Less Reactivity Shutdown Core Rod Worth 10-percent1 Requirements Margin Condition Configuration (Percent) (Percent) (Percent) (Percent)

BOL, HFP 53 rods in 8.46 52 rods in 7.43 6.69 2.60 4.09 highest worth rod stuck out EOL, HFP 53 rods in 7.98 52 rods in; 6.48 5.83 3.75 2.082 highest worth rod stuck out BOL = Beginning-of-life EOL = End-of-life HFP = Hot full power Notes:

1. Calculated rod worth is reduced by 10-percent to allow for uncertainties.
2. The design basis minimum shutdown margin is 1.95-percent.

Chapter 3, Page 72 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-4 DELETED TABLE 3.2-5 DELETED Chapter 3, Page 73 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-6 (Sheet 1 of 3)

Thermal and Hydraulic Design Parameters All Hipar All Lopar All OFA All Fuel Core5 Fuel Core5 Fuel Core5 VANTAGE+

Fuel Core6 Total heat Output, MWt 2758 2758 3071.4 3216 Total Heat Output, Btu/hr 9,413x106 9,413x106 10,483x106 10,973x106 Heat generated in fuel, 97.4 97.4 97.4 97.4 percent Nominal system 2250 2250 2250 2250 pressure, psia Coolant Flow Total flow rate, 129.57 128.3 121.72 123.3 x 106 lbs/hr1 Avg velocity along fuel 14.8 14.6 13.0 13.80 rods, ft/sec Avg mass flow, 2.42 2.39 2.21 2.24 x 106 lb/hr-ft2 Coolant temperature, oF Nominal inlet 541.6 541.3 547.7 538.2 Average rise in vessel 55.8 56.3 64.4 67.6 Average rise in core 58.2 58.7 67.9 71.8 Average in core 571.7 571.7 583.5 575.9 Average in vessel 569.5 569.5 579.7 572.0 Heat transfer Active heat transfer 51,400 52,100 52,100 52,100 surface area,ft2 Average heat flux, Btu/hr- 178,500 176,000 196,000 205,200 ft2 Maximum heat flux, 414,000 408,300 490,000 513,100 Btu/hr-ft2 Chapter 3, Page 74 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-6 (Sheet 2 of 3)

Thermal and Hydraulic Design Parameters All Hipar All All OFA All VANTAGE+

Fuel Core5 LOPAR Fuel Core5 Fuel Core6 Fuel Core5 Heat Transfer (continued)

Maximum thermal output for normal operation, KW/ft 13.42 13.42 15.863 16.63, 9 Maximum clad surface temperature for normal operation, °F 657 657 663 NA Fuel central temperatures for nominal fuel rod dimensions, °F Maximum at 100-percent power <4700 <4700 <4700 <4700 DNB ratio Minimum DNB ratio at nominal 1.95 1.84 2.45 2.40 operating conditions (Thimble)

Typical NA NA 2.33 2.50 Pressure drop, psi Across core 24.0 25.5 27.2 29.0 Across vessel, including nozzles 50.0 ~51.5 ~55.0 NA Chapter 3, Page 75 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-6 (Sheet 3 of 3)

Thermal and Hydraulic Design Parameters 3230 MWt 3230 MWt (Low Temp (High Temp Extreme) 7 Extreme) 7 NSSS Power, MWt 3230 3230 Core Power, MWt 3216 3216 Thermal Design Flow, Loop gpm 80,700 80,700 Reactor Thermal Design Flow, 126.8 123.3 Total, 106 lbm/hr Reactor Coolant Pressure, psia 2250 2250 Reactor Coolant Temperature, °F Core Outlet 588.1 610.0 Vessel Outlet 583.7 605.8 Core Average 552.6 575.9 Vessel Average 549.0 572.0 Vessel/Core Inlet 514.3 538.2 Zero Load Temperature 547 547 Percent Tube Plugging 108 108, 9 Core Bypass Percent 6.54 6.54 Notes:

1. The thermal design flow rate for all the all HIPAR core reflects a 5-percent flow reduction (to account for postulated 25-percent steam generator tube plugging). The thermal design flow rate for the all LOPAR core reflects a 6-percent flow reduction (5-percent reduction to account for postulated 25-percent steam generator tube plugging and an additional 1-percent reduction to account for an all LOPAR fuel core). For all OFA and all VANTAGE+

Fuel Cores, the thermal design flow rate reflects a 5-percent flow reduction (to account for postulated 10-percent steam generator tube plugging).

2. This power level is based upon a peaking factor (Fq) of 2.32.
3. This power level is based upon a peaking factor (Fq) of 2.50
4. Increased bypass flow is due to thimble plug deletion, and IFMs.
5. This data is historic only.
6. This data reflects the current core with uprated power of 3216 MWt.
7. This data is for analysis extremes covering a range of vessel average temperatures.
8. The tube plugging level is supported by the Thermal-hydraulic safety analyses.
9. Fuel pellet thermal conductivity degradation evaluations resulted in a reduction of the maximum steam generator tube plugging from 10% to 5%, a reduction of Fq from 2.5 to 2.3, and a reduction of Fdh from 1.70 to 1.65.

Chapter 3, Page 76 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-7 Core Mechanical Design Parameters1 Fuel assemblies Number 193 Rod array 15 x 15 Rods per assembly 2042 Rod pitch, in. 0.563 Overall dimensions 8.426 x 8.426 HIPAR6/LOPAR6 8.424 x 8.424 OFA 8.426 x 8.426 VANTAGE+/15x15 Upgraded Number of grids per assembly (HIPAR6/LOPAR6/OFA) 9 (VANTAGE+/15x15 Upgraded) 13 Number of instrumentation thimbles 1 Number of guide thimbles 20 Diameter of guide thimbles, upper part, in., HIPAR6 0.545 O.D. x 0.515 I.D.

Diameter of guide thimbles, lower part, in., HIPAR6 0.484 O.D. x 0.454 I.D.

Diameter of guide thimbles, upper part, in., LOPAR6 0.546 O.D. x 0.512 I.D.

Diameter of guide thimbles, lower part, in., LOPAR6 0.489 O.D. x 0.455 I.D.

Diameter of guide thimbles, upper part, in., OFA/V+ 0.533 O.D. x 0.499 I.D.

Diameter of guide thimbles, lower part, in., OFA/V+ 0.489 O.D. x 0.455 I.D.

Diameter of guide thimbles, upper part, in., 15x15 Upgraded 0.533 O.D. x 0.499 I.D.

Diameter of guide thimbles, lower part, in., 15x15 Upgraded 0.487 O.D. x 0.455 I.D.

Fuel rods Number 39,369 (+3 stainless steel rods)

Outside diameter, in. 0.422 Diametral gap, in. 0.0075 Clad thickness, in. 0.0243 Clad material Zircaloy (HIPAR6/LOPAR6/OFA)

ZIRLOTM (VANTAGE+/15x15 Upgraded)

Overall length 148.6, HIPAR6 151.9, LOPAR6 152.17, OFA 152.55, VANTAGE+

152.88,V+ w/P+

Enhancements/15x15 Upgraded Length of end cap, overall, in. 0.688, HIPAR6 0.265, LOPAR6 0.357 OFA/V+ (TOP) 0.430 OFA/V+ (BOTTOM) 0.350,V+w/P+/15x15 Upgraded (TOP) 0.810,V+w/P+/15x15 Upgraded (BOTTOM)

Length of end cap, inserted in rod 0.250, HIPAR6 0.200, LOPAR6 0.130, OFA/V+/15x15 Upgraded Active fuel length, in. 142, HIPAR6 144, LOPAR6 144, OFA/V+/15x15 Upgraded Chapter 3, Page 77 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-7 (Cont.)

Core Mechanical Design Parameters1 Fuel pellets Material UO2 sintered Density (percent of theoretical)

Region 21A 95.70 15x15 Upgraded Region 21B 95.62 15x15 Upgraded Region 22A 95.72 15x15 Upgraded Region 22B 95.73 15x15 Upgraded Region 23A 95.50 15x15 Upgraded Region 23B 95.50 15x15 Upgraded Feed enrichments w/o3 Region 21A 4.80 15x15 Upgraded Region 21B 4.95 15x15 Upgraded Region 22A 4.60 15x15 Upgraded Region 22B 4.95 15x15 Upgraded Region 23A 4.60 15x15 Upgraded Region 23B 4.95 15x15 Upgraded Diameter, in. 0.3659 Length, in. 0.4390 0.500 (Blanket)

Rod cluster control assemblies Neutron absorber 5-percent Cd, 15-percent In, 80-percent Ag Cladding material Type 304 SS - cold worked Clad thickness, in. 0.019 Number of clusters 53 Number of control rods per cluster 20 Length of rod control, in. 156.436 (overall)

Length of absorber section, in. 142.00 Chapter 3, Page 78 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3.2-7 (Cont.)

Core Mechanical Design Parameters1 Core structure Core barrel I.D., in. 148.0 O.D., in. 152.5 Thermal shield I.D., in. 158.5 O.D., in. 164.0 Wet Annular Burnable Absorber (WABA) Rods Number 1040 Pellet Stack Length 120 Pellet Material Al2O3-B4C Boron Loading (Natural) .0243 g/cm (B-10) .0060 g/cm Pellet O.D. /I.D. .318"/.278" Tube material ZIRLOTM Outer tube O.D. /I.D. .3810"/.3290" Inner tube O.D. /I.D. .2670"/.2250" Integral Fuel Burnable Absorber (IFBA) Rods Number 12032 Absorber Zirconium Diboride B-10 Loading (mg/inch)4 Deleted 2.21 (1.25X)

IFBA Coating Length Deleted128 inches Notes:

1. All dimensions are for cold conditions. Data is for all fuel types unless otherwise stated.
2. Twenty-one rods are omitted: Twenty provide passage for control rods and one contains incore instrumentation.
3. Reload fuel regions have variable enrichments depending on energy requirements, the number of assemblies being fed, and the degree of low leakage (i.e. number of feed assemblies on the periphery).
4. Nominal values.
5. Deleted
6. Symbol representing old and removed fuel assemblies.

Chapter 3, Page 79 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3.2 FIGURES Figure No. Title Figure 3.2-1 Typical Power Peaking Factor Versus Axial Offset Figure 3.2-2 Rod Cluster Groups - Cycle 1 [Historical]

Figure 3.2-3 Assembly Average Power & Burnup, Cycle 1 Calculations, BOL, Unrodded Core [Historical]

Figure 3.2-4 Assembly Average Power & Burnup, Cycle 1 Calculations, EOL, Unrodded Core [Historical]

Figure 3.2-5 Assembly Average Power Distribution Cycle 1 Calculations, BOL, Group C4 Inserted [Historical]

Figure 3.2-6 Assembly Average Power Distribution Cycle 1 Calculations, BOL Part-Length Rods In [Historical]

Figure 3.2-7 Cycle 1 Maximum FQ X Power Versus Axial Height During Normal Operation [Historical]

Figure 3.2-7A Deleted - See Unit 2 COLR For Normalized K (Z) - Fq Vs.

Axial Height For Cycle 17 Figure 3.2-8 Burnable Poison & Source Assembly Locations - Cycle 1 Figure 3.2-9 Burnable Poison Rod Locations - Cycle 1 [Historical]

Figure 3.2-10 Moderator Temperature Coefficient Vs Moderator Temperature - EOL, Cycle 1 [Historical]

Figure 3.2-11 Moderator Temperature Coefficient Vs Moderator Temperature - BOL, Cycle 1 Full Power [Historical]

Figure 3.2-12 Moderator Temperature Coefficient Vs Moderator Temperature - BOL, Cycle 1 Zero Power [Historical]

Figure 3.2-13 Doppler Coefficient Vs Effective Fuel Temperature - Cycle 1

[Historical]

Figure 3.2-14 Power Coefficient Vs Percent Power - Cycle 1 [Historical]

Figure 3.2-15 Power Coefficient - Closed Gap Model Figure 3.2-16 Deleted Figure 3.2-17 Deleted Figure 3.2-18 Deleted Figure 3.2-19 Deleted Figure 3.2-20 Deleted Figure 3.2-21 Deleted Figure 3.2-22 Deleted Figure 3.2-23 Deleted Figure 3.2-24 Deleted Figure 3.2-25 Deleted Figure 3.2-26 Deleted Figure 3.2-27 Deleted Figure 3.2-28 Deleted Figure 3.2-29 Deleted Figure 3.2-30 Deleted Figure 3.2-31 Deleted Figure 3.2-32 Deleted Figure 3.2-33 Deleted Chapter 3, Page 80 of 94 Revision 25, 2014

IP2 FSAR UPDATE Figure 3.2-34 Deleted Figure 3.2-35 Deleted Figure 3.2-36 Deleted Figure 3.2-37 Deleted Figure 3.2-38 Typical Thermal Conductivity Of UO2 Figure 3.2-39 High Power Fuel Rod Experimental Program Figure 3.2-40 Typical Comparison Of W-3 Prediction And Uniform Flux Data Figure 3.2-41 Typical W-3 Correlation Probability Distribution Curve Figure 3.2-42 Comparison Of "L" Grid Typical And Thimble Cold Wall Cell Rod Bundle DNB Data For Non-Uniform Axial Heat Flux With Predictions Of W-3 X F'SL Figure 3.2-43 Typical Comparison Of W-3 Correlation With Rod Bundle DNB Data (Simple Grid Without Mixing Vane)

Figure 3.2-44 Typical Comparison Of W-3 Correlation With Rod Bundle DNB Data (Simple Grid With Mixing Vane)

Figure 3.2-44A Typical Measured Versus Predicted Critical Heat Flux-WRB-1 Correlation Figure 3.2-45 Typical Stable Film Boiling Heat Transfer Data And Correlation Figure 3.2-46 Core Cross Section Figure 3.2-47 Reactor Vessel Internals Figure 3.2-48 Core Loading Arrangement - Cycle 1 [Historical]

Figure 3.2-49 Typical Rod Cluster Control Assembly Figure 3.2-50 Rod Control Cluster Assembly Outline Figure 3.2-51 Core Barrel Assembly Figure 3.2-52 Upper Core Support Structure Figure 3.2-53 Guide Tube Assembly Figure 3.2-54 Fuel Assembly And Control Cluster Cross Section - HIPAR, LOPAR, And OFA And VANTAGE+

Figure 3.2-55 HIPAR Fuel Assembly Figure 3.2-56 LOPAR Fuel Assembly Figure 3.2-56A OFA Fuel Assembly Figure 3.2-56B VANTAGE+ Fuel Assembly Figure 3.2-57 Guide Thimble To Bottom Nozzle Joint Figure 3.2-58 LOPAR Top Grid To Nozzle Attachment Figure 3.2-58A OFA And VANTAGE+ Top Grid To Nozzle Attachment Figure 3.2-59 Spring Clip Grid Assembly Figure 3.2-60 Mid-Grid Expansion Joint Design Plan View Figure 3.2-61 Elevation View - LOPAR Grid To Thimble Attachment Figure 3.2-61A Elevation View-VANTAGE+ Grid To Thimble Attachment Figure 3.2-61B Vantage+ Fuel Assembly With Performance+

Enhancements Figure 3.2-61C 15x15 Upgraded Fuel Assembly Figure 3.2-62 Cycle 1 - Neutron Source Locations [Historical]

Figure 3.2-63 HIPAR Burnable Poison Rod Figure 3.2-64 LOPAR Burnable Poison Rod Figure 3.2-65 Control Rod Drive Mechanism Assembly Figure 3.2-66 Control Rod Drive Mechanism Schematic Chapter 3, Page 81 of 94 Revision 25, 2014

IP2 FSAR UPDATE Figure 3.2-67 Thimble Location - Fixed Incore Detectors Figure 3.2-68 Cycle 14 Incore Detector, Thermocouple And Flow Mixing Device Locations Figure 3.2-68A Cycle 22 Region And Fuel Assembly Locations Figure 3.2-68B Cycle 22 Core Components And Fresh IFBA Locations Figure 3.2-69 Comparison Of Borosilicate Glass Absorber Rod With WABA Rod Figure 3.2-70 Wet Annular Burnable Absorber Rod 3.3 TESTS AND INSPECTIONS 3.3.1 Reactivity Anomalies To eliminate possible errors in the calculations of the initial reactivity of the core and the reactivity depletion rate, the predicted relation between fuel burnup and the boron concentration, necessary to maintain adequate control characteristics, must be adjusted (normalized) to reflect actual core conditions. When full power is reached initially, and with the control rod groups in the desired positions, the boron concentration is measured and the predicted curve adjusted to this point. As power operation proceeds, the measured boron concentration is compared with the predicted concentration and the slope of the curve relating burnup and reactivity was compared with that predicted. This process of normalization is completed before a cycle burnup of 60 Effective Full Power Days (EFPDs) is reached.

Thereafter, actual boron concentration is compared with prediction, and the reactivity status of the core can be continuously evaluated. Any reactivity anomaly greater than 1-percent would be unexpected, and its occurrence would be thoroughly investigated and evaluated. The methods employed in calculating the reactivity of the core versus burnup and the reactivity worth of boron versus burnup are given in Section 3.2.1.

3.3.2 Thermal And Hydraulic Tests And Inspections General hydraulic tests on models were used to confirm the design flow distributions and pressure drops.1,2 Fuel assemblies and control and drive mechanisms were also tested. Onsite measurements were made to confirm the design flow rates.

Vessel and internals inspections were also reviewed to check such thermal and hydraulic design values as bypass flow. As part of startup physics testing, a series of core power distribution measurements were made over the entire range of operation in terms of design control rod configuration by means of the core movable detector system. These measurements were analyzed and the results compared with the analytical predictions upon which the safety analysis was based with regard to both radial and axial power distribution. The design hot-channel factors were used as criteria for acceptable results.

3.3.3 Core Component Tests And Inspections To ensure conformance of all materials, components, and assemblies to the design requirements, a release point program is established with the assembly manufacturer, which requires upgrading of all raw materials, special processes (i.e., welding, heat treating, nondestructive testing, etc.) and those characteristics of detail parts, which directly affect the assembly and alignment of the reactor internals. The upgrading is accomplished by the issuance of an inspection release by quality control after conformance has been verified.

Chapter 3, Page 82 of 94 Revision 25, 2014

IP2 FSAR UPDATE A resident quality control representative performs a surveillance/audit program at the manufacturer's facility and witnesses the required tests and inspections and issues the inspection releases. An example is the radiographic examination of the welds joining core barrel shell courses.

Components and materials supplied by Westinghouse to the assembly manufacturer are subjected to a similar program. Quality control engineers develop inspection plans for all raw materials, components, and assemblies. Each level of manufacturing is evaluated by a qualified inspector for conformance, i.e., witnessing the ultrasonic testing of core plant raw material.

Upon completion of specified events, all documentation is audited prior to releasing the material or component for further manufacturing. All documentation and inspection releases are maintained in the quality control central records section. All materials are traceable to the mill heat number.

In conclusion, a set of "as-built" dimensions are taken to verify conformance to the design requirements and assure proper fit-up between the reactor internals and the reactor pressure vessel.

3.3.3.1 Quality Assurance Program The quality assurance program plan of the Westinghouse Nuclear Fuel Division is summarized in Reference 3.

The program provides for control over all activities affecting product quality, commencing with design and development and continuing through procurement, materials handling, fabrication, testing and inspection, storage, and transportation. The program also provides for the indoctrination and training of personnel and for the auditing of activities affecting product quality through a formal auditing program.

Westinghouse drawings and product, process, and materials specifications identify the inspections to be performed.

3.3.3.2 Quality Control Quality control philosophy is generally based on the following inspections being performed to a 95-percent confidence that at least 95-percent of the product meets specification, unless otherwise noted.

1. Fuel system components and parts The characteristics inspected depend upon the component parts; the quality control program includes dimensional and visual examinations, check audits of test reports, material certification, and nondestructive examination, such as X-ray and ultrasonic.

All material used in this core is accepted and released by quality control.

2. Pellets Inspection is performed for dimensional characteristics such as diameter, density, length, and squareness of ends. Additional visual inspections are Chapter 3, Page 83 of 94 Revision 25, 2014

IP2 FSAR UPDATE performed for cracks, chips, and surface conditions according to approved standards.

Density is determined in terms of weight per unit length and is plotted on zone charts used in controlling the process. Chemical analyses are performed on a specified sample basis throughout pellet production.

3. Rod inspection The fuel rod inspection consists of the following nondestructive examination techniques and methods, as applicable:
a. Each rod is leak tested using a calibrated mass spectrometer, with helium being the detectable gas.
b. Rod welds are inspected by ultrasonic test or X-ray in accordance with a qualified technique and Westinghouse specification.
c. All rods are dimensionally inspected prior to final release. The requirements include such items as length, camber, and visual appearance.
d. All fuel rods are inspected by gamma scanning or other approved methods to ensure proper plenum dimensions.
e. All fuel rods are inspected by gamma scanning, or other approved methods to ensure that no significant gaps exist between pellets.
f. All fuel rods are active gamma scanned to verify enrichment control prior to acceptance for assembly loading.
g. Traceability of rods and associated rod components is established by quality control.
4. Assemblies Each fuel assembly is inspected for compliance with drawing and/or specification requirements. Other incore control component inspection and specification requirements are given in paragraph 4.2.3.4 of Reference 3.
5. Other inspections The following inspections are performed as part of the routine inspection operation:
a. Tool and gauge inspection and control, including standardization to primary and/or secondary working standards. Tool inspection is performed at prescribed intervals on all serialized tools. Complete records are kept of calibration and conditions of tools.
b. Audits are performed of inspection activities and records to ensure that prescribed methods are followed and that records are correct and properly maintained.

Chapter 3, Page 84 of 94 Revision 25, 2014

IP2 FSAR UPDATE

c. Surveillance inspection, where appropriate, and audits of outside contractors are performed to ensure conformance with specified requirements.
6. Process control
a. To prevent the possibility of mixing enrichments during fuel manufacture and assembly, strict enrichment segregation and other process controls are exercised.

The uranium-dioxide powder is kept in sealed containers. The contents are fully identified both by descriptive tagging and preselected color coding. A Westinghouse identification tag completely describing the contents is affixed to the containers before transfer to powder storage. Isotopic content is confirmed by analysis.

Powder withdrawal from storage can be made by only one authorized group, which directs the powder to the correct pellet production line. All pellet production lines are physically separated from each other and pellets of only a single nominal enrichment and density are produced in a given production line at any given time.

Finished pellets are placed on trays identified with the same color code as the powder containers and transferred to segregated storage racks within the confines of the pelleting area. Samples from each pellet lot are tested for isotopic content and impurity levels prior to acceptance by quality control.

Physical barriers prevent mixing of pellets of different nominal densities and enrichments in this storage area. Unused powder and substandard pellets are returned to storage in the original color-coded containers.

Loading of pellets into the clad is performed in isolated production lines, and again only one enrichment and density loaded on a line at a time.

A serialized traceability code is placed on each fuel tube to provide unique identification. The end plugs are inserted and then inert-welded to seal the tube. The fuel tube remains coded and traceability identified until just prior to installation in the fuel assembly.

At the time of installation into an assembly, the traceability codes are removed and a matrix is generated to identify each rod in its position within a given assembly. The top nozzle is inscribed with a permanent identification number providing traceability to the fuel contained in the assembly.

Similar traceability is provided for burnable poison, source rods, and control rodlets, as required.

Chapter 3, Page 85 of 94 Revision 25, 2014

IP2 FSAR UPDATE REFERENCES FOR SECTION 3.3

1. G. Hetsroni, "Hydraulic Tests of the San Onofre Reactor Model, "WCAP-3269-8, Westinghouse Electric Corporation, 1964.
2. G. Hetsroni, "Studies of the Connecticut-Yankee Hydraulic Model, "WCAP-2761, Westinghouse Electric Corporation, 1965.
3. J. Moore, "Nuclear Fuel Division Quality Assurance Program Plan;" WCAP-7800, Revision 5, Westinghouse Electric Corporation, November 1979.

Chapter 3, Page 86 of 94 Revision 25, 2014

IP2 FSAR UPDATE Appendix 3A EXPERIMENTAL VERIFICATION OF CALCULATIONS FOR BORON BURNABLE POISON RODS A number of experiments were performed at the Westinghouse Reactor Evaluation Center to investigate the reactivity worth of Pyrex glass tubing similar to that employed in the Indian Point Unit 2 core as burnable poison rods. Several configurations with and without glass burnable poison rods and with fuel loadings representative of power reactors were tested. The reactor used was a rectangular core 4-ft high with 29 or 30 fuel rods on a side. In each case the water height was adjusted until the reactor was just critical.

Analyses were performed for each of the configurations measured to determine the adequacy of the methods used to calculate burnable poison rod worths in the design of the Indian Point Unit 2 core. The results of the calculations for the different experimental configurations are listed in Table 3A-1. In each case the eigenvalue should be compared to the appropriate reference eigenvalue (core with fuel only) to eliminate the systematic bias, which appears in the clean core calculation. The discrepancy between the eigenvalue calculated for the unpoisoned and poisoned cases has been related to the fractional error in the neutron current into the boron.

This error is also given in Table 3A-1.

The burnable poison rods used in Indian Point Unit 2 correspond to the thick-walled tubes and in these cases the agreement is generally better than 5-percent.

Chapter 3, Page 87 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3A-1 (Sheet 1 of 2)

Calculations and Burnable Poison Rod Worths1 Just Critical Calculated Keff Error in Poison Case Configuration Loading Water Height, cm For Critical Core Absorption, Percent 1 No inserts - clean 252 = 625 64.10 2 One solid glass rod 252-1 = 624 70.00 3 No inserts clean core 292 = 841 43.25 .9969152 4 Uniform thin wall glass 292-25 = 816 69.61 .994633 4.6 5 Uniform thick wall glass 292-25 = 816 83.81 .994800 3.5 6 Central assembly pattern - 292-72 = 769 39.52 1.000085 72 water holes 7 Central assembly pattern - 292-72 = 769 83.76 .996162 1.4 36 thin wall glass 36 water holes 8 Central assembly pattern - 292-72 = 769 114.95 .996392 0.8 36 thick wall glass 36 water holes 9 4 water holes array 292-16 = 825 42.25 10 No inserts - clean 302 = 900 40.69 .9965962 Chapter 3, Page 88 of 94 Revision 25, 2014

IP2 FSAR UPDATE TABLE 3A-1 (Sheet 2 of 2)

Calculations and Burnable Poison Rod Worths1 Just Critical Calculated Keff Error in Poison Case Configuration Loading Water Height, cm For Critical Core Absorption, Percent 11 Uniform water holes 302-36 = 864 38.91 .99777 12 Uniform voids (SS cladding) 302-36 = 864 42.62 13 Uniform thin wall glass tubes 302-36 = 864 67.18 .993915 4.8 14 Uniform thick wall glass tubes 302-36 = 864 82.56 .994875 2.5 15 Uniform - .260-in. Ag-In-Cd 302-32 = 868 92.34 16 Alternate thin wall glass tubes 302-18 = 882 49.42 .994963 6.2 17 Alternate thick wall glass tubes 302-18 = 882 51.90 .994965 5.1 18 Alternate solid glass rods - bare 302-18 = 882 54.91 .995925 1.8 19 Alternate pattern - Ag-In-Cd (.260) 302-18 = 882 53.89 20 Alternate pattern - Ag-In-Cd (.330) 302-18 = 882 59.94 21 Four assembly pattern - water holes 302-80 = 820 37.13 .999352 22 Four assembly pattern - 302-80 = 820 68.73 .997573 1.8 40 thick wall glass 40 water holes Notes:

1. Reactivity data of glass rods, encased in 0.020-in. SS 0.395-in. I.D., 0.435-in. O.D.

Nominal glass rod data: solid rod, 0.396-in. O.D., L = 48-in.; thick wall I.D. = 0.228-in., O.D. = 0.375-in.,

L = 48-in. thin wall I.D. = 0.316-in., O.D. = 0.394-in., L = 48-in.

2. Reference case.

Chapter 3, Page 89 of 94 Revision 25, 2014

IP2 FSAR UPDATE Appendix 3B POWER DISTRIBUTION CONTROL 3B.1 GENERAL The spatial stability of the xenon distribution in large PWRs has been the subject of extensive investigation by Westinghouse. General studies (performed in part under the Euratom Xenon Program) are reported in WCAP-3680-20, 21, 22, and 231-4 and specific studies related to the Indian Point Unit 2 reactor are reported in WCAP-7407-L5 (Westinghouse Proprietary). Confidence that the reactor can be maintained within thermal limits (design nuclear hot channel factors) is provided by the following:

1. Results of the extensive analytical investigation of potential spatial instability arising from redistribution of xenon in the Indian Point Unit 2 reactor lead to the conclusions that (a) the reactor may be unstable toward axial spatial oscillations and (b) is stable toward radial or diametral (quadrant to quadrant) xenon spatial oscillations.
2. Stability towards diametral (X-Y) xenon oscillations was demonstrated during Cycle 1 startup tests per a report submitted by Con Edison to the NRC (Reference 6).
3. Continuous monitoring and appropriate alarm functions of both axial and diametral power tilts, using signals from the eight ex-core ion chambers, with additional information provided by the core exit thermocouples and moveable incore flux detectors.
4. Since the core is expected to be X-Y stable, automatic protection against diametral transients is not required. However, an alarm function is provided to alert the operator to the existence of such tilts before a limiting value on diametral power tilt is reached.

Stability toward diametral oscillations was verified at startup. As burnup progresses, the reactor becomes increasingly stable toward diametral oscillations due to the decreasing soluble boron concentration and hence the continuously increasing moderator temperature coefficient feedback effect.

5. Control rod cluster malpositioning even under the most limiting case will not lead to a DNBR = 1.30 at operating conditions. Means for detecting such a misalignment are also provided.

Chapter 3, Page 90 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3B.2 SPATIAL XENON STABILITY 3B.2.1 AXIAL XENON STABILITY The potential existence of axial power distribution anomalies due to xenon redistribution have been reported in WCAP-7208.7 Results of these studies have shown that the reactor will be unstable toward xenon oscillations in this dimension; consequently, power shaping devices (i.e., control rods) and automatic protection (i.e., trip setpoint reduction with excessive axial power imbalance) are provided. Operating philosophy and procedures for monitoring and controlling axial power anomalies have been described in References 7 and

8. The primary means of detecting axial power distortions will be by means of the ex-core ion chambers with appropriate operator display signals. Tests in the Connecticut Yankee reactor (References 5 and 9) have verified the capability of these ex-core ion chambers to detect significant axial power imbalances.

3B.2.2 DIAMETRAL XENON STABILITY Results of the analytical investigations (primarily three-dimensional transient analyses reported in References 3 and 5) indicate that the Indian Point Unit 2 reactor will be stable toward diametral xenon oscillations; consequently, X-Y control rods are not required.

Comparison with experimental results in the Connecticut Yankee reactor tend to confirm the validity of the less conservative calculations (see Reference 5, Figure 3-1). A test was performed at startup to demonstrate that artificially induced diametral oscillations decrease in amplitude as a function of time. Furthermore, extensive monitoring with appropriate display and alarm function is provided to alert the operators in the event a diametral power tilt should develop in the course of reactor operation. Consequently, no automatic safety protection against diametral xenon instability is required.

3B.2.3 ANALYTICAL TECHNIQUES In assessing potential power distribution anomalies arising from spatial xenon redistribution, primary reliance has been placed on time-dependent two-group diffusion calculations in three-dimensions including pointwise feedback effects due to coolant density and fuel pellet temperature changes. Means of incorporating the reactivity feedback effects are described in References 2 and 3 using semi-empirically fitted expressions whose coefficients were determined by other calculations (e.g., LEOPARD). In some cases, survey calculations were performed in one or two dimensions using both digital and modal techniques (see Reference 1), to indicate trends and to identify the significance and relative importance of the various contributing parameters.

In performing three-dimensional time dependent stability analyses, standard design techniques (i.e., the LEOPARD Code) were used to compute the effect of the various feedback parameters on local reactivity. These results were fitted by a semi-empirical expression as described in Sections 2.2 and 3.3 of Reference 2. These analytical fits, with appropriate coefficients as determined from LEOPARD type calculations, were then used in the three-dimensional spatial power calculations, which included coupled thermal hydraulic effects.

Chapter 3, Page 91 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3B.2.4 INSTRUMENTATION AND CONTROL Instrumentation and appropriate display is provided to ensure that the reactor will be maintained within thermal limits (design hot nuclear channel factors) in the presence of power distribution anomalies caused by time-dependent xenon redistribution. Primary reliance is placed on the eight ex-core ion chambers supplemented by information derived from the core exit thermocouples and from the movable incore fission chambers.

The operator will have the ex-core detector information available, backed up by the core exit thermocouples and the movable incore detector readouts.

The following ex-core detector information is provided for the operator to alert him to the existence of any core instabilities, axial or diametral:

1. Four indicators, which indicate the difference between the top and bottom detectors. These signals will initiate alarms.
2. Eight indicators, which read out the individual currents of the four top and four bottom detectors.
3. One alarm for the four top detectors when the maximum to average flux is exceeded.
4. One alarm for the four bottom detectors when the maximum to average flux is exceeded.
5. Four 2-pen recorders; two detectors at 180 degrees are on the same recorder.
6. Two 2-pen recorders; power level proportional to total current, i.e., combined top and bottom detector outputs.
7. One total current deviation alarm, i.e., when any one top and bottom total current deviates by a pre-set amount from the other three total current outputs, the operator is alerted to this condition.

With these indications and alarms, the operator has many cross-checks and comparisons available to him. Failure of one top or bottom detector will provide the operator with instant indication and alarm. The ex-core detectors, backed by the movable incore detectors, provide more than adequate information. Operation with one ex-core ion chamber out of service does not compromise the safety of the plant.

Chapter 3, Page 92 of 94 Revision 25, 2014

IP2 FSAR UPDATE 3B.3 CONTROL ROD POSITIONING Normal control rod operations have been described in Section 3.0. A deviation in the position of one or more control clusters relative to the position of the control bank can potentially lead to:

1. Asymmetric fuel depletion.
2. Reduction in shutdown margin.
3. Reduction in DNB margin.

Rod misalignment is not a safety problem, which requires automatic protection because (1) asymmetric fuel depletion could possibly lead to unacceptable power distributions, but only if the condition were to persist for many hundreds of hours, (2) misalignment of sufficient magnitude to consume the standard 1-percent k shutdown is not possible, because it would require an entire control bank to be several feet below the desired position; the complete misalignment of a single control cluster will reduce trip reactivity by not more than 0.2-percent k; and (3) misalignment of a single control cluster by as much as the entire height of the core with the most pessimistic xenon spatial distribution will not result in a DNBR less than 1.30 at operating conditions. Deviation of 15-in. will not result in a power distribution worse than design.

Misalignment of a rod is most limiting when the last control group (which may be partly inserted at full power) is fully inserted but one cluster is full-out. It has been shown for Indian Point Unit 2 (Reference 5) that this case cannot lead to DNBR less than 1.30 at operating conditions even with the worst possible xenon distribution and the control bank (less one cluster) fully inserted.

Each control cluster has its own position indicator channel. The rod position indicator channel is sufficiently accurate to detect a rod +/-7.5-in. away from its demand position for indicated control rod position less than or equal to 210 steps withdrawn. An indicated misalignment 12 steps does not exceed the power peaking factor limits. A misaligned rod of +17 steps allows for greater instrumentation error when indicated control rod position is greater than or equal to 211 steps withdrawn. The reactivity worth of a rod at this core height (211 + steps) is not sufficient to perturb power shapes to the extent that peaking factors are affected.

The rod position indication system is the primary source of rod position information, but additional means, namely, ex-core ion chambers and movable incore fission chambers, are available.

Except for the central control rod cluster, a power tilt will result from any significant control rod misalignment and such a power tilt would be detected by the ex-core ion chambers.

Also, the movable incore fission chamber system can also be used to detect and/or investigate a suspected control rod malpositioning.

Chapter 3, Page 93 of 94 Revision 25, 2014

IP2 FSAR UPDATE REFERENCES FOR APPENDIX 3B

1. C. C. Poncelet and A. M. Christie, "Xenon-Induced Spatial Instabilities in Large Pressurized Water Reactors," WCAP-3680-20, Westinghouse Electric Corporation, March 1968.
2. F. B. Skogen and A. F. McFarlane, "Control Procedures for Xenon-Induced X-Y Instabilities in Large Pressurized Water Reactors," WCAP-3680-21, Westinghouse Electric Corporation, February 1969.
3. F. B. Skogen and A. F. McFarlane, "Xenon-Induced Spatial Instabilities in Three-Dimensions," WCAP-3680-22, Westinghouse Electric Corporation, September 1969.
4. A. M. Christie, et al., "Control of Xenon Instabilities in Large Pressurized Water Reactors," WCAP-3680-23, Westinghouse Electric Corporation, September 1969.
5. R. F. Barry, et al., "Power Maldistribution Investigations," WCAP-7407-L (Proprietary Class 2), Westinghouse Electric Corporation.
6. Letter from C. Newman, Con Ed, to AEC,

Subject:

Indian Point Unit No. 2 Results of the X-Y Xenon Stability Tests, dated October 17, 1974.

7. Westinghouse Electric Corporation, "Power Distribution Control of Westinghouse Pressurized Water Reactors," WCAP-7208 (APD Proprietary Class 2), September 1968.
8. T. Morita, et al., "Power Distribution Control and Load Following Procedures,"

WCAP-8385 (Proprietary), September 1974 and WCAP-8403 (Non-Proprietary),

September 1974.

9. R. J. Johnson, "Connecticut-Yankee Tests on Detection of Power Maldistribution,"

WCAP-9010 (NES Proprietary Class 2), Westinghouse Electric Corporation, February 1969.

Chapter 3, Page 94 of 94 Revision 25, 2014