|
|
(4 intermediate revisions by the same user not shown) |
Line 3: |
Line 3: |
| | issue date = 03/10/2016 | | | issue date = 03/10/2016 |
| | title = Request for Withholding Information from Public Disclosure, 2/10/16 Affidavit Executed by J. Gresham, Westinghouse Electric Company LLC LTR-PAFM-16-8 and LTR-PAFM-16-2-P, Revision 0, Relief Request 1B3-3 | | | title = Request for Withholding Information from Public Disclosure, 2/10/16 Affidavit Executed by J. Gresham, Westinghouse Electric Company LLC LTR-PAFM-16-8 and LTR-PAFM-16-2-P, Revision 0, Relief Request 1B3-3 |
| | author name = Singal B K | | | author name = Singal B |
| | author affiliation = NRC/NRR/DORL/LPLIV-1 | | | author affiliation = NRC/NRR/DORL/LPLIV-1 |
| | addressee name = Peters K J | | | addressee name = Peters K |
| | addressee affiliation = Luminant Generation Co, LLC | | | addressee affiliation = Luminant Generation Co, LLC |
| | docket = 05000445, 05000446 | | | docket = 05000445, 05000446 |
| | license number = NPF-087 | | | license number = NPF-087 |
| | contact person = Singal B K | | | contact person = Singal B |
| | case reference number = CAC MF6125 | | | case reference number = CAC MF6125 |
| | document type = Letter, Proprietary Information Review | | | document type = Letter, Proprietary Information Review |
| | page count = 4 | | | page count = 4 |
| | project = CAC:MF6125 | | | project = CAC:MF6125 |
| | stage = Other | | | stage = Withholding Request Acceptance |
| }} | | }} |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Ken J. Peters Senior Vice President and Chief Nuclear Officer (Acting) Attention: | | {{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 10, 2016 Mr. Ken J. Peters Senior Vice President and Chief Nuclear Officer (Acting) |
| Regulatory Affairs Luminant Generation Company LLC P.O. Box 1002 Glen Rose, TX 76043 March 10, 2016 | | Attention: Regulatory Affairs Luminant Generation Company LLC P.O. Box 1002 Glen Rose, TX 76043 |
|
| |
|
| ==SUBJECT:== | | ==SUBJECT:== |
| COMANCHE PEAK NUCLEAR POWER PLANT, UNIT 1 -REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (CAC NO. MF6125) | | COMANCHE PEAK NUCLEAR POWER PLANT, UNIT 1 - REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (CAC NO. MF6125) |
|
| |
|
| ==Dear Mr. Peters:== | | ==Dear Mr. Peters:== |
| By letter dated February 15, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML 16057A367), you submitted an affidavit to the U.S. Nuclear Regulatory Commission (NRC) dated February 10, 2016, executed by Mr. James A. Gresham, Manager, Regulatory Compliance, Westinghouse Electric Company LLC (Westinghouse), requesting that the information contained in the following documents be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Part 2, Section 2. 390: | | |
| * LTR-PAFM-16-8 | | By letter dated February 15, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16057A367), you submitted an affidavit to the U.S. Nuclear Regulatory Commission (NRC) dated February 10, 2016, executed by Mr. James A. Gresham, Manager, Regulatory Compliance, Westinghouse Electric Company LLC (Westinghouse), |
| -Responses to the NRC RAls [Request for Additional Information]
| | requesting that the information contained in the following documents be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Part 2, Section 2. 390: |
| Regarding Comanche Peak Unit 1 1 Extension of Required Inspection Frequency for Reactor Vessel Inlet Nozzle Dissimilar Metal Welds from 7 to 9 Calendar Years (Attachment A to Enclosure | | * LTR-PAFM-16 Responses to the NRC RAls [Request for Additional Information] Regarding Comanche Peak Unit 11 Extension of Required Inspection Frequency for Reactor Vessel Inlet Nozzle Dissimilar Metal Welds from 7 to 9 Calendar Years (Attachment A to Enclosure 1) |
| : 1)
| | * LTR-PAFM-16-2-P Revision 0 - Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds (Enclosure 2) |
| * L TR-PAFM-16-2-P Revision 0 -Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds (Enclosure | | The document was submitted in response to the NRC staff request for additional information in support of the Relief Request 1B3-3 submitted by letter dated April 20, 2015 (ADAMS Accession No. ML15119A216), for Comanche Peak Nuclear Power Plant, Unit 1. |
| : 2) The document was submitted in response to the NRC staff request for additional information in support of the Relief Request 1 B3-3 submitted by letter dated April 20, 2015 (ADAMS Accession No. ML 15119A216), for Comanche Peak Nuclear Power Plant, Unit 1. Non-proprietary versions of these documents, designated as Attachment B to Enclosure 1 and Enclosure 3 to the letter dated February 15, 2016, were also submitted and are available in ADAMS at Accession Nos. ML 16057A310 and ML 160547A311, respectively.
| | Non-proprietary versions of these documents, designated as Attachment B to Enclosure 1 and to the letter dated February 15, 2016, were also submitted and are available in ADAMS at Accession Nos. ML16057A310 and ML 160547A311, respectively. |
| 1 Westinghouse abbreviated Comanche Peak Nuclear Power Plant, Unit 1, as Comanche Peak Unit 1. | | 1 Westinghouse abbreviated Comanche Peak Nuclear Power Plant, Unit 1, as Comanche Peak Unit 1. |
| K. Peters In the affidavit dated February 10, 2016, Mr. Gresham stated that the submitted information should be considered exempt from the mandatory public disclosure for the following reasons: (a) The information reveals the distinguishing aspects of a process (or a component structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies. (c) Its use by competitor would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing a similar product. (e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse. | | |
| | K. Peters In the affidavit dated February 10, 2016, Mr. Gresham stated that the submitted information should be considered exempt from the mandatory public disclosure for the following reasons: |
| | (a) The information reveals the distinguishing aspects of a process (or a component structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies. |
| | (c) Its use by competitor would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing a similar product. |
| | (e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse. |
| We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.390 and, on the basis of the statements in the affidavit, have determined that the information sought to be withheld in the submittal, contains proprietary commercial inform.ation and should be withheld from public disclosure. | | We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.390 and, on the basis of the statements in the affidavit, have determined that the information sought to be withheld in the submittal, contains proprietary commercial inform.ation and should be withheld from public disclosure. |
| Therefore, the version of the submitted information marked as proprietary will be withheld from public disclosure pursuant to 10 CFR 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended. Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. | | Therefore, the version of the submitted information marked as proprietary will be withheld from public disclosure pursuant to 10 CFR 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended. |
| If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information. | | Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information. |
| If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information. | | If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information. In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure. |
| In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure. | | |
| K. Peters If you have any questions regarding this matter, I may be reached at (301) 415-3016. | | K. Peters If you have any questions regarding this matter, I may be reached at (301) 415-3016. |
| Docket Nos. 50-445 and 50-446 cc: J. A. Gresham, Manager Regulatory Compliance Westinghouse Electric Company 1000 Westinghouse Drive, Building 3 Suite310 Cranberry Township, PA 16066 Additional Distribution via Listserv Sincerely, b uQ. :i-
| | Sincerely, b uQ. :i-~I""-"'c(--- |
| "'c(---Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation K. Peters If you have any questions regarding this matter, I may be reached at (301) 415-3016. | | Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: J. A. Gresham, Manager Regulatory Compliance Westinghouse Electric Company 1000 Westinghouse Drive, Building 3 Suite310 Cranberry Township, PA 16066 Additional Distribution via Listserv |
| Docket Nos. 50-445 and 50-446 cc: J. A. Gresham, Manager Regulatory Compliance Westinghouse Electric Company 1000 Westinghouse Drive, Building 3 Suite310 Cranberry Township, PA 16066 Additional Distribution via Listserv DISTRIBUTION: | | |
| PUBLIC LPL4-1 Reading RidsACRS_MailCTR Resource RidsNrrDeEpnb Resource RidsNrrDorllpl4-1 Resource ADAMS Accession No.: ML 16053A446 OFFICE NRR/DORULPL4-1/PM NRR/DORULPL4-1/LA NAME BSingal JBurkhardt DATE 3/1/16 3/1/16 Sincerely, IRA/ Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsNrrPMComanchePeak Resource RidsNrrLAJBurkhardt Resource RidsRgn4MailCenter Resource JCollins, NRR/DE/EPNB AMargaret, NRR/DE/EPNB NRR/DE/EPNB/BC NRR/DORULPL4-1
| | ML16053A446 OFFICE NRR/DORULPL4-1/PM NRR/DORULPL4-1/LA NRR/DE/EPNB/BC NRR/DORULPL4-1 /BC NRR/DORULPL4-1 /PM NAME BSingal JBurkhardt DAiiey RPascarelli BSingal DATE 3/1/16 3/1/16 3/1/16 3/10/16 3/10/16}} |
| /BC DAiiey RPascarelli 3/1/16 3/10/16 NRR/DORULPL4-1 | |
| /PM BSingal 3/10/16 OFFICIAL RECORD COPY}} | |
Letter Sequence Withholding Request Acceptance |
---|
|
|
MONTHYEARCP-201500402, Relief Request 1B3-3 Inservice Inspection for Application of an Alternative to ASME Boiler & Pressure Vessel Code Section XI Examination Requirements for Reactor Pressure Vessel Cold Leg Weld Inspection Frequency2015-04-20020 April 2015 Relief Request 1B3-3 Inservice Inspection for Application of an Alternative to ASME Boiler & Pressure Vessel Code Section XI Examination Requirements for Reactor Pressure Vessel Cold Leg Weld Inspection Frequency Project stage: Request CP-201500999, Revision to Relief Request 1B3-3 Inservice Inspection for Application of an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Examination Requirements for Reactor Pressure Vessel Cold Leg Weld Inspection..2015-10-15015 October 2015 Revision to Relief Request 1B3-3 Inservice Inspection for Application of an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Examination Requirements for Reactor Pressure Vessel Cold Leg Weld Inspection.. Project stage: Request ML16015A0032016-01-14014 January 2016 NRR E-mail Capture - Request for Additional Information - Relief Request 1B3-3 for Comanche Peak Nuclear Power Plant, Unit 1 Project stage: RAI ML16057A3102016-02-12012 February 2016 Westinghouse LTR-PAFM-16-8 Attachment B - Responses to the NRC RAIs Re Comanche Peak Unit 1 Extension of Required Inspection Frequency for Reactor Vessel Inlet Nozzle Dissimilar Metal Welds from 7 to 9 Calendar Years Project stage: Other ML16057A3092016-02-15015 February 2016 Response to Request for Additional Information Re Relief Request 1B3-3 Project stage: Response to RAI CP-201600097, Westinghouse LTR-PAFM-16-2-NP, Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds.2016-02-29029 February 2016 Westinghouse LTR-PAFM-16-2-NP, Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds. Project stage: Other ML16053A4462016-03-10010 March 2016 Request for Withholding Information from Public Disclosure, 2/10/16 Affidavit Executed by J. Gresham, Westinghouse Electric Company LLC LTR-PAFM-16-8 and LTR-PAFM-16-2-P, Revision 0, Relief Request 1B3-3 Project stage: Withholding Request Acceptance ML16074A0012016-03-14014 March 2016 Relief Request 1B3-3, Alternative for Reactor Pressure Vessel Cold Leg Weld Inspection Frequency from Not to Exceed 7 Years to 9 Years for the Third 10-Year Inservice Inspection Interval Project stage: Other 2016-02-12
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000445/20240032024-10-30030 October 2024 Integrated Inspection Report 05000445/2024003 and 05000446/2024003 IR 05000445/20244042024-10-23023 October 2024 Security Baseline Inspection Report 05000445/2024404 and 05000446/2024404 (Public) IR 07200074/20244012024-10-10010 October 2024 Independent Spent Fuel Storage Installation Security Inspection Report 07200074/2024401 Public 05000445/LER-2024-002-01, Condition Prohibited by Technical Specifications Due to Inoperable Remote Shutdown System Functions2024-10-0303 October 2024 Condition Prohibited by Technical Specifications Due to Inoperable Remote Shutdown System Functions 05000446/LER-2024-001-01, Unit Two, Recurring Reactor Scrams Associated with Main Feedwater System Modifications2024-09-30030 September 2024 Unit Two, Recurring Reactor Scrams Associated with Main Feedwater System Modifications CP-202400335, License Amendment Request to Adopt TSTF-51, TSTF-471, and TSTF-571-T to Eliminate Use of the Term Core Alterations and Revise Requirements During Handling of Irradiated Fuel2024-09-12012 September 2024 License Amendment Request to Adopt TSTF-51, TSTF-471, and TSTF-571-T to Eliminate Use of the Term Core Alterations and Revise Requirements During Handling of Irradiated Fuel ML24031A6322024-09-11011 September 2024 Exemption from the Requirements of 10 CFR 50.71(e)(4), Final Safety Analysis Report Update Schedule (EPID L-2023-LLE-0023) - Letter ML24243A0152024-09-0303 September 2024 – Notification of Comprehensive Engineering Team Inspection (05000445/2025012 and 05000446/2025012) and Request for Information ML24194A1332024-08-28028 August 2024 Issuance of Amendment Nos. 190 and 190, Respectively, Revision to Technical Specifications to Adopt TSTF-589, Eliminate Automatic Diesel Generator Start During Shutdown ML24228A2252024-08-22022 August 2024 Relief to Use Later Code Edition for Inservice Inspection Program ML24179A0772024-08-20020 August 2024 Issuance of Amendment Nos. 189 and 189, Respectively, Extension of Allowed Outage Time for an Inoperable Emergency Diesel Generator ML24232A2262024-08-19019 August 2024 Information Request, Security IR 2024404 ML24232A2412024-08-19019 August 2024 Information Request, ISFSI Security IR 2024401 CP-202400294, (CPNPP) - Response to RAI for Exemption Request from 10 CPR 50.71(e)(4) Final Safety Analysis Update Schedule2024-08-15015 August 2024 (CPNPP) - Response to RAI for Exemption Request from 10 CPR 50.71(e)(4) Final Safety Analysis Update Schedule IR 05000445/20240052024-08-15015 August 2024 Updated Inspection Plan for Comanche Peak Nuclear Power Plant, Units 1 and 2 (Report 05000445/2024005 and 05000446/2024005) CP-202400319, (CPNPP) - Revision to CPNPP Letter to the NRC, Multiple Relief Requests for Unit 2 Third Ten-Year Inservice Inspection Interval from 10CFR50.55(a) Inspection Requirements Due to Impracticality2024-08-13013 August 2024 (CPNPP) - Revision to CPNPP Letter to the NRC, Multiple Relief Requests for Unit 2 Third Ten-Year Inservice Inspection Interval from 10CFR50.55(a) Inspection Requirements Due to Impracticality ML24177A2692024-08-0707 August 2024 Issuance of Amendment Nos. 188 and 188, Respectively, Revision to Technical Specifications to Adopt TSTF-591, Revise Risk Informed Completion Time (RICT) Program CP-202400315, (Cpnpp), Multiple Relief Requests for Unit 2 Third Ten-Year Inservice Inspection Interval from 10CFR50.55(a) Inspection Requirements Due to Impracticality2024-08-0505 August 2024 (Cpnpp), Multiple Relief Requests for Unit 2 Third Ten-Year Inservice Inspection Interval from 10CFR50.55(a) Inspection Requirements Due to Impracticality IR 05000445/20240022024-07-31031 July 2024 Units 1 and 2 - Integrated Inspection Report 05000445/2024002 and 05000446/2024002,and Independent Spent Fuel Storage Installation Inspection Report 07200074/2024001 IR 05000445/20244032024-07-16016 July 2024 Security Baseline Inspection Report 05000445/2024403 and 05000446/2024403 (Full Report) ML24187A0372024-07-15015 July 2024 Withdrawal of Requested Licensing Action Exemption from Select Requirements of 10 CFR Part 55, Operators Licenses ML24192A1862024-07-10010 July 2024 Notification of Inspection (NRC Inspection Report 05000445/2024003 and 05000446/2024003) and Request for Information ML24185A1382024-07-0202 July 2024 Inservice Inspection Request for Information IR 05000445/20244012024-06-26026 June 2024 MC&A Program Inspection Report 05000445-2024401 and 05000446-2024401 Public-Final CP-202400253, (Cpnpp), Units 1 & 2 Inservice Testing Plan for Pumps & Valves Third Interval, Revision 52024-06-26026 June 2024 (Cpnpp), Units 1 & 2 Inservice Testing Plan for Pumps & Valves Third Interval, Revision 5 CP-202400235, (Cpnpp), Units 1 & 2, Inservice Testing Plan for Pumps & Valves Fourth Interval, Revision 02024-06-18018 June 2024 (Cpnpp), Units 1 & 2, Inservice Testing Plan for Pumps & Valves Fourth Interval, Revision 0 IR 05000445/20240122024-06-17017 June 2024 Design Basis Assurance Inspection (Programs) Inspection Report 05000445/2024012 and 05000446/2024012 ML24120A3632024-06-10010 June 2024 Issuance of Amendment Nos. 187 and 187, Respectively Adoption of 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Plants 05000445/LER-1924-002, (Cpnpp), Unit 1, Condition Prohibited by Technical Specifications Due to Inoperable Remote Shutdown System Functions2024-06-0303 June 2024 (Cpnpp), Unit 1, Condition Prohibited by Technical Specifications Due to Inoperable Remote Shutdown System Functions CP-202400205, (Cpnpp), Units 1and 2, Submittal of the Snubber Inservice Program Plan for the Fourth Ten Year Interval2024-05-30030 May 2024 (Cpnpp), Units 1and 2, Submittal of the Snubber Inservice Program Plan for the Fourth Ten Year Interval CP-202400175, (CPNPP) - Supplement to License Amendment Request to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator2024-05-16016 May 2024 (CPNPP) - Supplement to License Amendment Request to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator 05000446/LER-2024-001, (Cpnpp), Unit 2, Two Recurring Reactor Scrams Associated with Main Feedwater System Modifications2024-05-13013 May 2024 (Cpnpp), Unit 2, Two Recurring Reactor Scrams Associated with Main Feedwater System Modifications 05000445/LER-2024-001, Re Potential Loss of Safety Function Due to Inoperability of Both Trains of Uninterruptible Power Supply Heating, Ventilation & Air Conditioning2024-05-0606 May 2024 Re Potential Loss of Safety Function Due to Inoperability of Both Trains of Uninterruptible Power Supply Heating, Ventilation & Air Conditioning ML24120A3032024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-SpottedBird, L, Kiowa Indian Tribe ML24120A2982024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Martinez, E, Mescalero Apache Tribe ML24120A3002024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Morrow, R K, Thlopthlocco Tribal Town ML24120A3022024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Pierite, M, Tunica-Biloxi Tribe of Louisiana ML24120A2922024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Dotson, Delaware Nation CP-202400153, (Cpnpp), Registration of Dry Spent Fuel Storage Canisters2024-04-29029 April 2024 (Cpnpp), Registration of Dry Spent Fuel Storage Canisters ML24120A3052024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Woommavovah, M, Comanche Nation ML24120A3012024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Parton, T, Wichita and Affiliated Tribes ML24120A2942024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Gonzalez, B, Caddo Nation ML24120A3062024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Yahola, s, Kialegee Tribal Town ML24120A2952024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Johnson, L.J., Seminole Nation of Oklahoma ML24120A2932024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Garza, Jr, Juan, Kickapoo Traditional Tribe of Texas ML24120A2962024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Kaskaske, D, Kickapoo Tribe of Oklahoma ML24120A2972024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Martin, R, Tonkawa Tribe of Oklahoma ML24120A2912024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Cooper, D, Apache Tribe of Oklahoma ML24120A3042024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Sylestine, R, Alabama-Coushatta Tribe of Texas ML24120A3072024-04-29029 April 2024 Lr Feis Section 106 Consultation Letters, Tribes-Yargee, W, Alabama-Quassarte Tribal Town 2024-09-30
[Table view] Category:Proprietary Information Review
MONTHYEARML23023A0012023-02-0202 February 2023 Request for Withholding Information from Public Disclosure ML16085A1482016-04-0606 April 2016 Request for Withholding Information from Public Disclosure - 3/14/16 Affidavit Executed by T. Mccool, Luminant Generation Company LLC Balance Sheets (Proprietary) ML16053A4462016-03-10010 March 2016 Request for Withholding Information from Public Disclosure, 2/10/16 Affidavit Executed by J. Gresham, Westinghouse Electric Company LLC LTR-PAFM-16-8 and LTR-PAFM-16-2-P, Revision 0, Relief Request 1B3-3 ML15351A0572016-01-19019 January 2016 Request for Withholding Information from Public Disclosure, Affidavit Dated 12/9/15 Executed by T. Mccool, Luminant Generation Company LLC Balance Sheets (CAC MF7075-MF7076) ML14192B0422014-08-21021 August 2014 Denial, Request for Withholding from Public Disclosure - 4/2/14 Affidavit Executed by J. Gresham, Westinghouse Enclosures 1 Through 3 Provided on Cds in Response to Request for Additional Information (TAC MF1099-1100) ML14150A1422014-06-30030 June 2014 Request for Withholding Information from Public Disclosure - 4/17/14 Affidavit Executed by J. Gresham, Westinghouse; Responses to Request for Additional Information SFP Configuration Interfaces (TAC MF1365-MF1366) ML14150A1382014-06-30030 June 2014 Request for Withholding Information from Public Disclosure - 7/12/13 Affidavit Executed by B. Maurer, Westinghouse; Supplemental Information Supporting Amendment Request Question 1, 2, and 4 (TAC MF1365-MF1366) ML14022A0462014-03-19019 March 2014 Request for Withholding Proprietary Information from Public Disclosure ML13318A0292014-03-19019 March 2014 Request for Withholding Information from Public Disclosure, 10/14/13 Affidavit Executed by J. Gresham, Westinghouse Regarding WCAP-17728-P, Revision 1 ML14007A0392014-02-0606 February 2014 Request for Withholding Information from Public Disclosure - 11/22/13 Affidavit Executed by J. Gresham, Westinghouse Responses to 11/5/13 NRC Requests for Additional Information ML13253A0062013-09-26026 September 2013 Request for Withholding Information from Public Disclosure, 3/18/13 Affidavit Executed by J. Gresham, Westinghouse Regarding WCAP-17728-P, Revision 0 ML12361A3462013-01-22022 January 2013 Request for Withholding Information from Public Disclosure, 11/26/12 Affidavit Executed by Fred Madden, Luminant Generation Co. LLC, Balance Sheets Included as Enclosure 1 ML12361A3542013-01-22022 January 2013 Request for Withholding Information from Public Disclosure, 12/5/12 Affidavit Executed by Fred Madden, Luminant Generation Co. LLC, Balance Sheets Included as Enclosure 1 ML12347A0842012-12-21021 December 2012 Request for Withholding Information from Public Disclosure, 10/11/12 Affidavit Executed by Fred Madden, Luminant Generation Co. LLC Balance Sheets Included as Enclosure 1, Exhibit D ML1034705962011-01-10010 January 2011 Request for Withholding Information from Public Disclosure, 12/5/2010 Affidavit Executed by J. Gresham, Westinghouse, WCAP-17330-P ML0926703042009-10-16016 October 2009 Request for Withholding Information from Public Disclosure, 5/21/2009 Affidavit Executed by J. Gresham, Westinghouse ML0925103102009-09-25025 September 2009 Request for Withholding Information from Public Disclosure ML0921201322009-08-13013 August 2009 Request for Clarification on Request for Withholding Information from Public Disclosure, 5/21/2009 Affidavit Executed by J. Gresham, Westinghouse ML0903707802009-03-27027 March 2009 Request for Withholding Information from Public Disclosure ML0821305092008-08-25025 August 2008 Request for Withholding Information from Public Disclosure, Affidavit Dated 6/26/08, Executed by R. Sisk, Westinghouse ML0806602512008-03-12012 March 2008 Request for Withholding Information from Public Disclosure (Re 2/20/08 Affidavit Executed by J. Gresham, Westinghouse) (Tac Nos. MD6615 and MD6616) ML0801501112008-01-28028 January 2008 Units and 2 - Request for Withholding Proprietary Information, J. Gresham, Westinghouse Electric Company LLC Affidavit Dated 12/11/2007, Regarding LAR 07-006 ML0731300292007-11-20020 November 2007 Request for Withholding Information from Public Disclosure Power Stretch Uprate (C. Savage, Westinghouse 10/23/07 Affidavit) ML0728200252007-11-0606 November 2007 Request for Withholding Information from Public Disclosure WCAP-16827-P (Tac Nos. MD6615 and MD6616) ML0728200122007-11-0606 November 2007 Request for Withholding Information from Public Disclosure Proprietary Request for Stretch Power Uprate Information (Tac Nos. MD6615 and MD6616) ML0716300022007-06-19019 June 2007 Request for Withholding Information from Public Disclosure - Txu Generation Company LP and Tx Energy Future Holdings LP Affidavits ML0412110232004-04-27027 April 2004 Withholding from Public Disclosure, Attachment 6A to TXX-03187, Topical Report Applicability Determination ML0329404712003-10-20020 October 2003 Request for Withholding Information from Public Disclosure Concerning Westinghouse Proprietary Letter WPT-16357 and Drawing 1061E26, Sheet 1, Rev. B and Sheet 2, Rev -, MB7684 ML0315702862003-06-0404 June 2003 Txu Energy, Comanche Peak, Unit 1, Withholding from Public Disclosure, Westinghouse Report SG-SGDA-02-43-P & Westinghouse Report SG-SGDA-03-03-P, MB8456 ML0312802562003-05-0808 May 2003 Withholding from Public Disclosure Proprietary Westinghouse Letter WPT-16357 & Westinghouse Proprietary Drawing 1061E26, Sheet 1, Revision B, and Sheet 2, Revision, MB7984 & MB7985 ML0128404092002-01-16016 January 2002 Withholding from Public Disclosure, Proprietary Topical Report ERX-2001-005-P, Zirlo Cladding & Boron Coating Models for Txu Electric'S Loss of Coolant Accident Analysis Methodologies. 2023-02-02
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 10, 2016 Mr. Ken J. Peters Senior Vice President and Chief Nuclear Officer (Acting)
Attention: Regulatory Affairs Luminant Generation Company LLC P.O. Box 1002 Glen Rose, TX 76043
SUBJECT:
COMANCHE PEAK NUCLEAR POWER PLANT, UNIT 1 - REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (CAC NO. MF6125)
Dear Mr. Peters:
By letter dated February 15, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16057A367), you submitted an affidavit to the U.S. Nuclear Regulatory Commission (NRC) dated February 10, 2016, executed by Mr. James A. Gresham, Manager, Regulatory Compliance, Westinghouse Electric Company LLC (Westinghouse),
requesting that the information contained in the following documents be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Part 2, Section 2. 390:
- LTR-PAFM-16 Responses to the NRC RAls [Request for Additional Information] Regarding Comanche Peak Unit 11 Extension of Required Inspection Frequency for Reactor Vessel Inlet Nozzle Dissimilar Metal Welds from 7 to 9 Calendar Years (Attachment A to Enclosure 1)
- LTR-PAFM-16-2-P Revision 0 - Technical Justification to Support Extended Volumetric Examination Interval for Comanche Peak Unit 1 Reactor Vessel Inlet Nozzle to Safe End Dissimilar Metal Welds (Enclosure 2)
The document was submitted in response to the NRC staff request for additional information in support of the Relief Request 1B3-3 submitted by letter dated April 20, 2015 (ADAMS Accession No. ML15119A216), for Comanche Peak Nuclear Power Plant, Unit 1.
Non-proprietary versions of these documents, designated as Attachment B to Enclosure 1 and to the letter dated February 15, 2016, were also submitted and are available in ADAMS at Accession Nos. ML16057A310 and ML 160547A311, respectively.
1 Westinghouse abbreviated Comanche Peak Nuclear Power Plant, Unit 1, as Comanche Peak Unit 1.
K. Peters In the affidavit dated February 10, 2016, Mr. Gresham stated that the submitted information should be considered exempt from the mandatory public disclosure for the following reasons:
(a) The information reveals the distinguishing aspects of a process (or a component structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies.
(c) Its use by competitor would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing a similar product.
(e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.
We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.390 and, on the basis of the statements in the affidavit, have determined that the information sought to be withheld in the submittal, contains proprietary commercial inform.ation and should be withheld from public disclosure.
Therefore, the version of the submitted information marked as proprietary will be withheld from public disclosure pursuant to 10 CFR 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended.
Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.
If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information. In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.
K. Peters If you have any questions regarding this matter, I may be reached at (301) 415-3016.
Sincerely, b uQ. :i-~I""-"'c(---
Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: J. A. Gresham, Manager Regulatory Compliance Westinghouse Electric Company 1000 Westinghouse Drive, Building 3 Suite310 Cranberry Township, PA 16066 Additional Distribution via Listserv
ML16053A446 OFFICE NRR/DORULPL4-1/PM NRR/DORULPL4-1/LA NRR/DE/EPNB/BC NRR/DORULPL4-1 /BC NRR/DORULPL4-1 /PM NAME BSingal JBurkhardt DAiiey RPascarelli BSingal DATE 3/1/16 3/1/16 3/1/16 3/10/16 3/10/16