ML17252B443: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(7 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17252B443
| number = ML17252B443
| issue date = 04/07/1976
| issue date = 04/07/1976
| title = LER 76-016-00 for Dresden 2 Regarding a Discovery of a Through-Wall Crack In The 14-Inch HPCI Sensitized Stainless Steel Safe-End
| title = LER 76-016-00 for Dresden 2 Regarding a Discovery of a Through-Wall Crack in the 14-Inch HPCI Sensitized Stainless Steel Safe-End
| author name = Stephenson B B
| author name = Stephenson B
| author affiliation = Commonwealth Edison Co
| author affiliation = Commonwealth Edison Co
| addressee name = Keppler J G
| addressee name = Keppler J
| addressee affiliation = NRC/RGN-III
| addressee affiliation = NRC/RGN-III
| docket = 05000237
| docket = 05000237
Line 15: Line 15:
| page count = 3
| page count = 3
}}
}}
=Text=
{{#Wiki_filter:,.
Commonwealth Ason Dresden Nuclear Pow~ation R.R. #1 Morris, Illinois 60450 Telephone 815/942-2920 BBS Ltr. #76-290                          April 7, 19 76 Mr. James G. Keppler, Regional Director Directorate of Regulatory Operations - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ell~n, Illinois              60137 Enclosed please find Reportable Occurrence number 50-237/1976-16. This report is being submitted to your office in accordance with.the Dresden Nuclear Power Station Technical Specifications, Section 6.6.B.
BBS:aw Enclosure cc:    Director of Inspection & Enforcement Director of Manage*ment Information & Program Control Fiie/NRC
* ENSEE EVENT REPORT                                *
                      **                              I CONTROL BLOCK: ....~----1..__.._I          __._I____.I___.I                            [PLEASE PRINT ALL REQUIRED INFORMATION]
1                            6 LICENSEE                                                                                        LICENSE                EVENT NAME                        ,              LICENSE NUMBER                                      TYPE                  TYPE
  @EJ IIIJ..l:PI £1 S.IJ I                          10101-10101010101-10101 14 I 1 I 11 I r I t I 1011 I 7  8 9                                    14      15                                                    25    26                    30      31    32 REPORT        REPORT CATEGORY          TYPE      SOURCE    * ,        DOCKET NUMBER                              EVENT DATE                        REPORT OATL
  @ill CON'T I I I *lI..1                        LhJ      101s101-101~13171                              1013121417101                    10 14- I o 17 IClJ I ~ I 7    8          57        5B        5!:)      60      61                                      68    69                      74    75                          80
        . EVENT DESCRIPTION lol2l I :Dvg1NG-                AN          IN~~/.?..VtC<=        IN~Pt:CflotJ              OF TH'G UJJIT-J_ PR1rr1ARY                    s YS'I&#xa3; fY1 9 A 7    8 9                                                                                                                                                              80
  @@) I rH~OUG-H -WALL                            CRACK          we~ Dl$CO\ICQ,ED IN THE lLf- -,f NCH                                HPCI S"N$111ZEDI 7    8 9                            .                                                                                                                                  80 lol41  I SIA I IV l-&#xa3;S.<;            STEEL                                                                                                                                  I 7    8 9                                                                                                                                                              80
  ~      I \cJAT9e              A!\/D        wA~ LDCttrcP                01R&#xa3;cTL.y fff IHf 80-rrorvt or !Hf P1PE.                                    ?./x INCH              I 7  8  9.                                                                                                                                        >                  80 IQIID      f="Rom          THE        Sfl.F'&#xa3;-eAJO-TO-P1P                        WEL(>.                          1Cf7b-    1<0) 7    8 9                                                                          PRIME                                                                              80 SYSTEM          CAUSE                                                COMPONENT              COMPONENT
            . CODE          CODE                  COMPONENT CODE                  SUPPLIER            MANUFACTURER          VIOLATION
  @0 ICIEI ~                                IPlt IPIE:IXIXI                        lt{J            IB 1011 15"147              lNJ 48    .
7 8 9 10                      11        12                            17            43          44.
CAUSE DESCRIPTION
  ~.I "11-1&#xa3;              C..RACKEO S'Ar::-END                    WAS C..lJT            OUI        ANifJJ SENI TD              8ATTELU! trlEmOR/ AL , .
.7    8 9                              .              .                            ~-----                              _ _ _ _ _____,._,,...~~ 80
  ~      I tNS'Trf'IJTE'- C.OJ..UrYlBVS                  l.ABo~Aro~1S cro~.. M&#xa3;T81-L.J.H~&ICAl. ANA~Y5!~. Pf2..tL.1 m1_Ntl1Z-Y Rt:'SL>_'1-"TSI 7    8 9                                                                                                                                                              80
  ~      I 11\101 c..a.-i:o      IH~ THc TH*wuc.H-wALI- CR.ACK lOUITtL> 3/g 1NCH FRcM IHE' WE~P W.J!l5;                                                                        I 7    8 9      FACILITY                                                                    METHOD OF                          (~t:E: ltf-rfk.tfct> S HCe'T)            80 STATUS              % POWER                      OTHER STATUS              DISCOVERY                      DISCOVERY DESCRIPTION EE]            UiJ              le>IOIOI                          NA                        l.ill 7    8        9                10                12 13                              44      45 FORM OF ACTIVITY          CONTENT rn 7    8 RELEASED 9
                ~
OF RELEASE l6j 10
_I_ _
11 AMOUNT OF ACTIVITY N_A----'-----'
44        45 LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER            TYPE          DESCRIPTION IT@    1010101 1&#xa3;1                                        Nii 7    8 9                  11      12        13                                                                                                                      80 PERS'ONNEL INJURIES NUMBER              DESCRIPTION      .
EE]lololol11 7 89 NA 1~2~~~~~.-~~~~~~~~~~~~~~~~~~~~~~~~~~~                                                                                              ............
80 OFFSITE CONSEQUENCES
~*                        NII 7    8 9                                                                                                                                                              80 LOSS OR DAMAGE TO FACILITY TYPE        DESCRIPTION EI~l~                ~_,_JJ_~"'--~~~~~~~~~~~~~~~~~~~-----..,~~~. . . . . .
7    8 9          10                                                                                                                                                80 PUBLICITY
@?]
7    8 9                                                                                                                                                              80 ADDITIONAL FACTORS IT@                        NA 7    8 9                                                                                                                                                              80 PHONE: cx-r.        .l.~ s:
GPO 881
* 667
CAUSE DESCRIPTION (continued)
-1/4 in-ch- long -at the O.D: and 2 inches long at the I.D~, running circum-ferentially. Two axial cracks between 1/2 inch and 1 inch in length were also found on the I.D. surface, emanating from the safe ... end-to-pipe weld.
Analysis of the!?e cracks has not yee been completed. An update report will be submitted when results become available.
The  cracked safe-end was manufac~ured from SA-182 F316 stainless steel and was  unclad. The safe-end had been furnace-sensitized during manufacture. The replacement safe-end will be either SA-182 F316L stain-less steel or    SA-105 carbon steel.}}

Latest revision as of 20:08, 29 October 2019

LER 76-016-00 for Dresden 2 Regarding a Discovery of a Through-Wall Crack in the 14-Inch HPCI Sensitized Stainless Steel Safe-End
ML17252B443
Person / Time
Site: Dresden Constellation icon.png
Issue date: 04/07/1976
From: Stephenson B
Commonwealth Edison Co
To: James Keppler
NRC/RGN-III
References
BBS Ltr. #76-290 LER 76-016-00
Download: ML17252B443 (3)


Text

,.

Commonwealth Ason Dresden Nuclear Pow~ation R.R. #1 Morris, Illinois 60450 Telephone 815/942-2920 BBS Ltr. #76-290 April 7, 19 76 Mr. James G. Keppler, Regional Director Directorate of Regulatory Operations - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ell~n, Illinois 60137 Enclosed please find Reportable Occurrence number 50-237/1976-16. This report is being submitted to your office in accordance with.the Dresden Nuclear Power Station Technical Specifications, Section 6.6.B.

BBS:aw Enclosure cc: Director of Inspection & Enforcement Director of Manage*ment Information & Program Control Fiie/NRC

  • ENSEE EVENT REPORT *
    • I CONTROL BLOCK: ....~----1..__.._I __._I____.I___.I [PLEASE PRINT ALL REQUIRED INFORMATION]

1 6 LICENSEE LICENSE EVENT NAME , LICENSE NUMBER TYPE TYPE

@EJ IIIJ..l:PI £1 S.IJ I 10101-10101010101-10101 14 I 1 I 11 I r I t I 1011 I 7 8 9 14 15 25 26 30 31 32 REPORT REPORT CATEGORY TYPE SOURCE * , DOCKET NUMBER EVENT DATE REPORT OATL

@ill CON'T I I I *lI..1 LhJ 101s101-101~13171 1013121417101 10 14- I o 17 IClJ I ~ I 7 8 57 5B 5!:) 60 61 68 69 74 75 80

. EVENT DESCRIPTION lol2l I :Dvg1NG- AN IN~~/.?..VtC<= IN~Pt:CflotJ OF TH'G UJJIT-J_ PR1rr1ARY s YS'I£ fY1 9 A 7 8 9 80

@@) I rH~OUG-H -WALL CRACK we~ Dl$CO\ICQ,ED IN THE lLf- -,f NCH HPCI S"N$111ZEDI 7 8 9 . 80 lol41 I SIA I IV l-£S.<; STEEL I 7 8 9 80

~ I \cJAT9e A!\/D wA~ LDCttrcP 01R£cTL.y fff IHf 80-rrorvt or !Hf P1PE.  ?./x INCH I 7 8 9. > 80 IQIID f="Rom THE Sfl.F'£-eAJO-TO-P1P WEL(>. 1Cf7b- 1<0) 7 8 9 PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT

. CODE CODE COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION

@0 ICIEI ~ IPlt IPIE:IXIXI lt{J IB 1011 15"147 lNJ 48 .

7 8 9 10 11 12 17 43 44.

CAUSE DESCRIPTION

~.I "11-1£ C..RACKEO S'Ar::-END WAS C..lJT OUI ANifJJ SENI TD 8ATTELU! trlEmOR/ AL , .

.7 8 9 . . ~----- _ _ _ _ _____,._,,...~~ 80

~ I tNS'Trf'IJTE'- C.OJ..UrYlBVS l.ABo~Aro~1S cro~.. M£T81-L.J.H~&ICAl. ANA~Y5!~. Pf2..tL.1 m1_Ntl1Z-Y Rt:'SL>_'1-"TSI 7 8 9 80

~ I 11\101 c..a.-i:o IH~ THc TH*wuc.H-wALI- CR.ACK lOUITtL> 3/g 1NCH FRcM IHE' WE~P W.J!l5; I 7 8 9 FACILITY METHOD OF (~t:E: ltf-rfk.tfct> S HCe'T) 80 STATUS  % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION EE] UiJ le>IOIOI NA l.ill 7 8 9 10 12 13 44 45 FORM OF ACTIVITY CONTENT rn 7 8 RELEASED 9

~

OF RELEASE l6j 10

_I_ _

11 AMOUNT OF ACTIVITY N_A----'-----'

44 45 LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION IT@ 1010101 1£1 Nii 7 8 9 11 12 13 80 PERS'ONNEL INJURIES NUMBER DESCRIPTION .

EE]lololol11 7 89 NA 1~2~~~~~.-~~~~~~~~~~~~~~~~~~~~~~~~~~~ ............

80 OFFSITE CONSEQUENCES

~* NII 7 8 9 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION EI~l~ ~_,_JJ_~"'--~~~~~~~~~~~~~~~~~~~-----..,~~~. . . . . .

7 8 9 10 80 PUBLICITY

@?]

7 8 9 80 ADDITIONAL FACTORS IT@ NA 7 8 9 80 PHONE: cx-r. .l.~ s:

GPO 881

  • 667

CAUSE DESCRIPTION (continued)

-1/4 in-ch- long -at the O.D: and 2 inches long at the I.D~, running circum-ferentially. Two axial cracks between 1/2 inch and 1 inch in length were also found on the I.D. surface, emanating from the safe ... end-to-pipe weld.

Analysis of the!?e cracks has not yee been completed. An update report will be submitted when results become available.

The cracked safe-end was manufac~ured from SA-182 F316 stainless steel and was unclad. The safe-end had been furnace-sensitized during manufacture. The replacement safe-end will be either SA-182 F316L stain-less steel or SA-105 carbon steel.