| number = ML063410430
| number = ML063410430
| issue date = 11/21/2006
| issue date = 11/21/2006
| title = Haddam Neck Plant, Final Status Survey Final Report Phase Iv, Appendix A14, Survey Unit Release Record 9106-0014, Discharge Canal
| title = Final Status Survey Final Report Phase IV, Appendix A14, Survey Unit Release Record 9106-0014, Discharge Canal
| author name = Newson C T
| author name = Newson C
| author affiliation = Connecticut Yankee Atomic Power Co
| author affiliation = Connecticut Yankee Atomic Power Co
| addressee name =  
| addressee name =  
Line 62: Line 62:
17 mrem/yrsoil+2 mrem/yrExisting GW+O mreml/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Table 2 -Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1) Base Case Soil Operational DCGL Required MDC DCGL (pCi/g) (2) (pCi/g) (3) (pCi/g) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.10E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+0 1 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu- 152 1.01 E+0 I 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O 1 2.01E+01 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mremlyr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
17 mrem/yrsoil+2 mrem/yrExisting GW+O mreml/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Table 2 -Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1) Base Case Soil Operational DCGL Required MDC DCGL (pCi/g) (2) (pCi/g) (3) (pCi/g) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.10E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+0 1 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu- 152 1.01 E+0 I 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O 1 2.01E+01 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mremlyr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Initial characterization was performed in April of 2004 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration  
Initial characterization was performed in April of 2004 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration
(<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.
(<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.
The LTP (by way of equation 5-31) states that if residual radioactivity exists in an isolated area of elevated activity in addition to residual radioactivity distributed relatively uniformly across a survey unit, the unity rule will be used to ensure the total dose is within the release criterion.
The LTP (by way of equation 5-31) states that if residual radioactivity exists in an isolated area of elevated activity in addition to residual radioactivity distributed relatively uniformly across a survey unit, the unity rule will be used to ensure the total dose is within the release criterion.
Line 90: Line 90:
All analyses were performed to the required MDC.Cs-137 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in thirty-seven (37) and Co-60 was positively identified in thirty-four (34) of the forty-two (42) samples.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed a total seven (7) samples for full HTD analysis as required by the sample plan, and for gamma results that indicated additional testing was warranted.
All analyses were performed to the required MDC.Cs-137 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in thirty-seven (37) and Co-60 was positively identified in thirty-four (34) of the forty-two (42) samples.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed a total seven (7) samples for full HTD analysis as required by the sample plan, and for gamma results that indicated additional testing was warranted.
The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC.Several of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.One of the sample results (9106-0014-033F) exceeded the Operational DCGL and required further investigation.
The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC.Several of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.One of the sample results (9106-0014-033F) exceeded the Operational DCGL and required further investigation.
A summary of the sample results is provided in Table 5.Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCi/g pCi/g Operational DCGL ()9106-0014-OO1F 1.41E-03 8.94E-03 3.71E-03 9106-0014-002F 3.61E-03 2.52E-03 1.64E-03 9106-0014-003F 3.95E-06 1.15E-02 4.44E-03 9106-0014-005F 5.45E-02 2.88E-02 2.12E-02 9106-0014-006F 2.42E-01 2.67E-01 1.48E-01 9106-0014-007F 1.61E-01 2.17E-01 1.14E-01 9106-0014-008F 9.66E-02 1.60E-01 7.97E-02 9106-0014-009F 1.64E-01 5.99E-02 5.36E-02 9106-0014-OIOF 3.63E-01 2.38E-01 1.59E-01 9106-0014-01 IF 3.56E-02 5.76E-03 8.84E-03 9106-0014-012F 1.15E+00 1.45E+00 7.74E-01 Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCs/g 137g COperational pCi/g pCi/g DCGL (')9106-0014-013F 2.19E-01 1.36E-01 9.32E-02 9106-0014-014F 1.47E-02 1 .13E-02 7.10E-03 9106-0014-015F 5.85E-02 1.68E-01 7.57E-02 9106-0014-016F 6.89E-02 1.05E-01 5.33E-02 9106-0014-017F 5.52E-01 5.93E-01 3.32E-01 9106-0014-018F 2.93E-01 8.95E-01 4.OOE-01 9106-0014-019F 7.49E-01 1.32E+00 6.49E-0 1 9106-0014-020F 5.94E-02 6.60E-02 3.65E-02 9106-0014-021F 1.17E-01 4.50E-01 1.95E-01 9106-0014-022F  
A summary of the sample results is provided in Table 5.Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCi/g pCi/g Operational DCGL ()9106-0014-OO1F 1.41E-03 8.94E-03 3.71E-03 9106-0014-002F 3.61E-03 2.52E-03 1.64E-03 9106-0014-003F 3.95E-06 1.15E-02 4.44E-03 9106-0014-005F 5.45E-02 2.88E-02 2.12E-02 9106-0014-006F 2.42E-01 2.67E-01 1.48E-01 9106-0014-007F 1.61E-01 2.17E-01 1.14E-01 9106-0014-008F 9.66E-02 1.60E-01 7.97E-02 9106-0014-009F 1.64E-01 5.99E-02 5.36E-02 9106-0014-OIOF 3.63E-01 2.38E-01 1.59E-01 9106-0014-01 IF 3.56E-02 5.76E-03 8.84E-03 9106-0014-012F 1.15E+00 1.45E+00 7.74E-01 Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCs/g 137g COperational pCi/g pCi/g DCGL (')9106-0014-013F 2.19E-01 1.36E-01 9.32E-02 9106-0014-014F 1.47E-02 1 .13E-02 7.10E-03 9106-0014-015F 5.85E-02 1.68E-01 7.57E-02 9106-0014-016F 6.89E-02 1.05E-01 5.33E-02 9106-0014-017F 5.52E-01 5.93E-01 3.32E-01 9106-0014-018F 2.93E-01 8.95E-01 4.OOE-01 9106-0014-019F 7.49E-01 1.32E+00 6.49E-0 1 9106-0014-020F 5.94E-02 6.60E-02 3.65E-02 9106-0014-021F 1.17E-01 4.50E-01 1.95E-01 9106-0014-022F
: 1. 15E-01 2.89E-02 3.25E-02 9106-0014-023F 4.53E-02 4.90E-02 2.73E-02 9106-0014-024F 2.41E-02 -1.63E-03 3.85E-03 9106-0014-025F 5.50E-01 1.36E+00 6.27E-01 9106-0014-026F 1.20E-01 1.52E-01 8.1 OE-02 9106-0014-027F 1.66E-0 1 4.69E-01 2.12E-01 9106-0014-028F 8.72E-02 1.86E-01 8.80E-02 9106-0014-029F 5.80E-02 9.38E-02 4.70E-02 9106-0014-03OF 3.89E-02 2.49E-02 1.68E-02 9106-0014-031 F 3.85E-02 3.90E-02 2.22E-02 9106-0014-032F 2.55E-01 3.98E-01 2.01E-01 9106-0014-033F 1.36E+00 2.07E+00 1.05E+00 9106-0014-034F 3.OOE-01 1.01 E+00 4.46E-01 9106-0014-035F 2.OOE-01 2.49E-01 1.33E-01 9106-0014-036F 7.85E-02 3.41E-01 1.46E-0 I 9106-0014-037F 3.26E-01 1.23E+00 5.35E-01 9106-0014-038F 3.47E-01 1.60E+00 6.82E-01 9106-0014-039F 3.77E-01 1.36E+00 5.95E-01 9106-0014-040F 9.62E-02 4.36E-01 1.86E-01 9106-0014-041 F 4.76E-02 1.47E-01 6.56E-02 9106-0014-042F 1.52E-01 6.66E-01 2.85E-01 9106-0014-043F 1.29E-0 1 1.08E-01 6.57E-02 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve a seventeen (17) mrem/yr TEDE The off-site laboratory also processed a total of seven (7) samples for HTD analysis as required by the sample plan. Five (5) of the seven (7) samples were statistical locations that were selected at random. The remaining two (2)samples, were selected for additional testing based on having the highest dose equivalence, based on gamma spectroscopy measurements.
: 1. 15E-01 2.89E-02 3.25E-02 9106-0014-023F 4.53E-02 4.90E-02 2.73E-02 9106-0014-024F 2.41E-02 -1.63E-03 3.85E-03 9106-0014-025F 5.50E-01 1.36E+00 6.27E-01 9106-0014-026F 1.20E-01 1.52E-01 8.1 OE-02 9106-0014-027F 1.66E-0 1 4.69E-01 2.12E-01 9106-0014-028F 8.72E-02 1.86E-01 8.80E-02 9106-0014-029F 5.80E-02 9.38E-02 4.70E-02 9106-0014-03OF 3.89E-02 2.49E-02 1.68E-02 9106-0014-031 F 3.85E-02 3.90E-02 2.22E-02 9106-0014-032F 2.55E-01 3.98E-01 2.01E-01 9106-0014-033F 1.36E+00 2.07E+00 1.05E+00 9106-0014-034F 3.OOE-01 1.01 E+00 4.46E-01 9106-0014-035F 2.OOE-01 2.49E-01 1.33E-01 9106-0014-036F 7.85E-02 3.41E-01 1.46E-0 I 9106-0014-037F 3.26E-01 1.23E+00 5.35E-01 9106-0014-038F 3.47E-01 1.60E+00 6.82E-01 9106-0014-039F 3.77E-01 1.36E+00 5.95E-01 9106-0014-040F 9.62E-02 4.36E-01 1.86E-01 9106-0014-041 F 4.76E-02 1.47E-01 6.56E-02 9106-0014-042F 1.52E-01 6.66E-01 2.85E-01 9106-0014-043F 1.29E-0 1 1.08E-01 6.57E-02 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve a seventeen (17) mrem/yr TEDE The off-site laboratory also processed a total of seven (7) samples for HTD analysis as required by the sample plan. Five (5) of the seven (7) samples were statistical locations that were selected at random. The remaining two (2)samples, were selected for additional testing based on having the highest dose equivalence, based on gamma spectroscopy measurements.
A number of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).
A number of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).
Line 140: Line 140:
E] 30 D. E] 14 D. E] 7 D. Container Sample Size- ..Media Type &Type ComnPeevto Lab ,. " , Sample Designation Date Time Code Code Code Comment, Preservation Lab Sale'lD 9106-0014-021F 6/15/06 10:50 SE C BP X Transferred from COC 2006-00407 9106-0014-030F 6/15/06 11:20 SE C BP X Transferred from COC 2006-00407 9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409 P.. :- ..9106-0014-OIOF 6/12/06 14:23 SE C BP X Transferred from COC 2006-00391 9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391  
E] 30 D. E] 14 D. E] 7 D. Container Sample Size- ..Media Type &Type ComnPeevto Lab ,. " , Sample Designation Date Time Code Code Code Comment, Preservation Lab Sale'lD 9106-0014-021F 6/15/06 10:50 SE C BP X Transferred from COC 2006-00407 9106-0014-030F 6/15/06 11:20 SE C BP X Transferred from COC 2006-00407 9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409 P.. :- ..9106-0014-OIOF 6/12/06 14:23 SE C BP X Transferred from COC 2006-00391 9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391  
......9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP xI Transferred from COC 2006-00385
......9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP xI Transferred from COC 2006-00385
_V .. -1 1 ..-______4 Vv NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA Li Radwaste QA[] Non QA 1) Relinquished By Date ime 2) R eved By ) --- Date/Time 3) Relinquished By Date/Time  
_V .. -1 1 ..-______4 Vv NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA Li Radwaste QA[] Non QA 1) Relinquished By Date ime 2) R eved By ) --- Date/Time 3) Relinquished By Date/Time
: 4) ved By "atefime Samples Shipped Via:[ Fed Ex Li uPs Li Hand Li Other Bill of Lading #flZ 4?sV 3W-7 Terfp.: E~g. C tustody~Sealed?
: 4) ved By "atefime Samples Shipped Via:[ Fed Ex Li uPs Li Hand Li Other Bill of Lading #flZ 4?sV 3W-7 Terfp.: E~g. C tustody~Sealed?
Th't N'7.CUstody" Sea~lIntact?
Th't N'7.CUstody" Sea~lIntact?
Y 2, K 5) Relinquished By Date/Time 6) Received By Date/Time 1 1 Health Physics Procedure/U GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 5 W I ~ I Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00457 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0<843 556 8171. Attn. Cheryl Jones Priority:E]
Y 2, K 5) Relinquished By Date/Time 6) Received By Date/Time 1 1 Health Physics Procedure/U GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 5 W I ~ I Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00457 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0<843 556 8171. Attn. Cheryl Jones Priority:E]
30 D. Z 14 D. R 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID) 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 9106-0014-03 IF 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387
30 D. Z 14 D. R 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID) 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 9106-0014-03 IF 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387
[ 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387 9106-0014-038F 6/9/06 10:59 SE C BP _ X Transferred from COC 2006-00387 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 0l oj a 6i 0 M I/91 06-001 4-042F 6/9/06 09.53 SE C BP x Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP 9106-0014-034F 6/9/06 10:11 SE C BP x Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA F1 Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: __ Deg. C 0C'ts F] UPS El Hand Custody Sealed?YO NO 1) Relinquished By Date/Time  
[ 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387 9106-0014-038F 6/9/06 10:59 SE C BP _ X Transferred from COC 2006-00387 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 0l oj a 6i 0 M I/91 06-001 4-042F 6/9/06 09.53 SE C BP x Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP 9106-0014-034F 6/9/06 10:11 SE C BP x Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA F1 Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: __ Deg. C 0C'ts F] UPS El Hand Custody Sealed?YO NO 1) Relinquished By Date/Time
: 2) Re d By Dat ime Custody Seal Intact?J/I~P1Ei~c~~  
: 2) Re d By Dat ime Custody Seal Intact?J/I~P1Ei~c~~  
~ /tO~/LcO 7Other 3) Relinquished By Date/Time -ate/ime BillofLading
~ /tO~/LcO 7Other 3) Relinquished By Date/Time -ate/ime BillofLading
_Y_ NO Bill of Lading #R 5) Relinquished By Date/Time  
_Y_ NO Bill of Lading #R 5) Relinquished By Date/Time
: 6) Received By Date/Time / 4 qsV Health Physics Procedure I I -I-(V Tullf '/ -GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00458 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C Priority:  
: 6) Received By Date/Time / 4 qsV Health Physics Procedure I I -I-(V Tullf '/ -GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00458 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C Priority:
[] 30 D. E 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID Xt 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387)t '9106-0014-009F 6/13/06 08:44 SE C BP X Transferred from COC 2006-00392 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP X Transferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-003929106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392 9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA E LTP QA El Radwaste QA E Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: ___ Deg. C EI uPs 0 Hand Custody Sealed?YE NO 1) Relinquished By Date/Time  
[] 30 D. E 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID Xt 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387)t '9106-0014-009F 6/13/06 08:44 SE C BP X Transferred from COC 2006-00392 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP X Transferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-003929106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392 9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA E LTP QA El Radwaste QA E Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: ___ Deg. C EI uPs 0 Hand Custody Sealed?YE NO 1) Relinquished By Date/Time
: 2) Rec ived By Date/Time Custody Seal Intact?A-11 P C*P_ -r- :L- 0 2 'V lI Other 3) Relinquished By Date/Tim e 4) K keived By Efate/! ime Bill of LadiY N E Bill of Lading #5) Relinquished By Date/Time  
: 2) Rec ived By Date/Time Custody Seal Intact?A-11 P C*P_ -r- :L- 0 2 'V lI Other 3) Relinquished By Date/Tim e 4) K keived By Efate/! ime Bill of LadiY N E Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 7., 0, Health Physics Procedure i(;- 4  /GPP-GGGR-R5 104-003-Attachiment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-0045!
: 6) Received By Date/Time 7., 0, Health Physics Procedure i(;- 4  /GPP-GGGR-R5 104-003-Attachiment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-0045!
362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested L.b.W;, ,. ,., .A Contact Name & Phone: , Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories  
362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested L.b.W;, ,. ,., .A Contact Name & Phone: , Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories  
Line 162: Line 162:
..Sample Size- , Media Type &Type Pervto b 0nplC , Sample Designation Date Time Code Code Code Comment, Preservation  
..Sample Size- , Media Type &Type Pervto b 0nplC , Sample Designation Date Time Code Code Code Comment, Preservation  
-.,-P- I 9106-0014-0031 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396  
-.,-P- I 9106-0014-0031 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396  
-.9106-0014-008FS 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396  
-.9106-0014-008FS 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396
[.......9106-0014-014F 6/14/06 10:23 SE C BP X Transferred from COC 2006-00396 , NOTES: PO #: 002332 MSR #: 06- SSWP# NA 0 LTP QA Lj Radwaste QA [I Non QA Samples Shipped Via: e n g,~ Fed Ex Tj.: 0I UPS E] Hand a/; td0 e 1) Relinquished By Dat /Time 2) Recei d By /  jvme p'tLE &#xfd;' i11cIit Other :.>3) Relinquished By Date/Time 4)'&#xfd; i d B-y hate/Time
[.......9106-0014-014F 6/14/06 10:23 SE C BP X Transferred from COC 2006-00396 , NOTES: PO #: 002332 MSR #: 06- SSWP# NA 0 LTP QA Lj Radwaste QA [I Non QA Samples Shipped Via: e n g,~ Fed Ex Tj.: 0I UPS E] Hand a/; td0 e 1) Relinquished By Dat /Time 2) Recei d By /  jvme p'tLE &#xfd;' i11cIit Other :.>3) Relinquished By Date/Time 4)'&#xfd; i d B-y hate/Time
________-.________
________-.________
Line 185: Line 185:
....__7. Sample holding times exceeded?
....__7. Sample holding times exceeded?
Yes J4,No [ ]8. Samples have."&#xfd; ._._hazard labels_Z_ custody seals " --appropriate sample labels 9. Samples are:..in good condition leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ J No 11. .Description of anomalies (include sample numbers): Telephoned to:. "On lBy is-Connecticut Yankee Statement of Work for Analytical Lab Services Cy-ISC-SOW-O00 Figure 1. Sample Check-in List.Date/rime Received: SDG#: A&#xfd;Spu~ 69 Work Order Number:______________________
Yes J4,No [ ]8. Samples have."&#xfd; ._._hazard labels_Z_ custody seals " --appropriate sample labels 9. Samples are:..in good condition leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ J No 11. .Description of anomalies (include sample numbers): Telephoned to:. "On lBy is-Connecticut Yankee Statement of Work for Analytical Lab Services Cy-ISC-SOW-O00 Figure 1. Sample Check-in List.Date/rime Received: SDG#: A&#xfd;Spu~ 69 Work Order Number:______________________
________Shipping Container ID: 19 " Chain of Custody 4 O6, # -A g)c /". Custody Seals ori shipping container intact?. -Yes &#xfd;-go []2. Custody Seals dated and signed? Yes*,,-No  
________Shipping Container ID: 19 " Chain of Custody 4 O6, # -A g)c /". Custody Seals ori shipping container intact?. -Yes &#xfd;-go []2. Custody Seals dated and signed? Yes*,,-No
[I..3. Chain-of-Custody record prpsent? Yes D.no (1 4. Cooler temperature  
[I..3. Chain-of-Custody record prpsent? Yes D.no (1 4. Cooler temperature  
,9- .5. Vermiculite/packing materials is: Wet t\ I 6.: Number of samples in shipping container  
,9- .5. Vermiculite/packing materials is: Wet t\ I 6.: Number of samples in shipping container  
Line 265: Line 265:
Miscellaneous Information:
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
The following NCR was generated for this SDG: NCR 339793 was generated due to Container scanning event for custody missed. 1. Container scanning event for custody missed: The analyst did not scan the samples into the batch prior to analysis, however the samples did remain in their custody at all times. 167014 041,042,043,044,045,046,047  
The following NCR was generated for this SDG: NCR 339793 was generated due to Container scanning event for custody missed. 1. Container scanning event for custody missed: The analyst did not scan the samples into the batch prior to analysis, however the samples did remain in their custody at all times. 167014 041,042,043,044,045,046,047
: 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.
: 1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.
Additional Comments 30 The relative percent difference (1201136627 (9106-0014-027FS) and 167014041 (9106-0014-027FS))
Additional Comments 30 The relative percent difference (1201136627 (9106-0014-027FS) and 167014041 (9106-0014-027FS))
Line 333: Line 333:
GEL requires all analytical data to be verified by a qualified data validator.
GEL requires all analytical data to be verified by a qualified data validator.
In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:
In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:
Reviewer/Date:  
Reviewer/Date:
(-5;i&41 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 339793 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:
(-5;i&41 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 339793 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:
Quality Criteria:
Quality Criteria:
Line 561: Line 561:
, 9106-0011-012F 5/17/06 08:41 SE C BP X x Transferred from COC 2006-00356 9106-0011-012FS 5/17/06 08:41 SE C BP X X Transferred from COC 2006-00356.'
, 9106-0011-012F 5/17/06 08:41 SE C BP X x Transferred from COC 2006-00356 9106-0011-012FS 5/17/06 08:41 SE C BP X X Transferred from COC 2006-00356.'
9106-0011-014F 5/17/06 09:34 SE C BP X x Transferred from COC 2006-00356 17 ., .9106-0011-015F 5/17/06 09:12 SE C BP X x Transferred from COC 2006-00356 9106-0011-018F 5/17/06 10:01 SE C BP X x Transferred from COC 2006-00356  
9106-0011-014F 5/17/06 09:34 SE C BP X x Transferred from COC 2006-00356 17 ., .9106-0011-015F 5/17/06 09:12 SE C BP X x Transferred from COC 2006-00356 9106-0011-018F 5/17/06 10:01 SE C BP X x Transferred from COC 2006-00356  
.9106-0011-002F 5/15/06 14:33 SE C BP X x Transferred from COC 2006-00352 9106-0011-003F 5/15/06 14:58 SE C BP X Transferred from COC 2006-00352 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA [I Radwaste QA El Non QA Samples Shipped Via: l":i-te ..al~Fed Ex O~t1 O~ C ~ ~ ~ '(2\O(~ LIUPS LI Hand 1) Relinquished By DaterTime  
.9106-0011-002F 5/15/06 14:33 SE C BP X x Transferred from COC 2006-00352 9106-0011-003F 5/15/06 14:58 SE C BP X Transferred from COC 2006-00352 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA [I Radwaste QA El Non QA Samples Shipped Via: l":i-te ..al~Fed Ex O~t1 O~ C ~ ~ ~ '(2\O(~ LIUPS LI Hand 1) Relinquished By DaterTime
: 2) Recei ate/Time Q ea JAI -4C tooE] the a 3) Relinquished By Date/Time  
: 2) Recei ate/Time Q ea JAI -4C tooE] the a 3) Relinquished By Date/Time
: 4) Received By Date/Time Bill of Lading #5) Relinquished By Date/Time  
: 4) Received By Date/Time Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 7?tV ;3. -' 0  
: 6) Received By Date/Time 7?tV ;3. -' 0  
* : SAMPLE RECEIPT & REVIEW FORM riOM use only Client: CO N ad rNlt ISDG/ARCOC/Work Order: /Date Received:
* : SAMPLE RECEIPT & REVIEW FORM riOM use only Client: CO N ad rNlt ISDG/ARCOC/Work Order: /Date Received:
Line 585: Line 585:
_7. Sample holding times exceeded?
_7. Sample holding times exceeded?
Yes p.] No [].8. Samples have: "tape &#xa3;._L hazard labels* A _custody seals __Sc_. appropriate sample labels 9. Samples are'9 -_in good condition -leaking-broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes [J No I(1.. Description of anomalies (include sample numbers): S.ample Custodian/Laboratory:Y Date: d i ot -0730.Telephoned to: On B _ __ _ _ _Page 9 of 108; Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major oq 00 00 Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power CompanyC No. 2006-00451 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556  
Yes p.] No [].8. Samples have: "tape &#xa3;._L hazard labels* A _custody seals __Sc_. appropriate sample labels 9. Samples are'9 -_in good condition -leaking-broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes [J No I(1.. Description of anomalies (include sample numbers): S.ample Custodian/Laboratory:Y Date: d i ot -0730.Telephoned to: On B _ __ _ _ _Page 9 of 108; Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major oq 00 00 Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power CompanyC No. 2006-00451 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556  
/M67_ _______'Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r Priority:  
/M67_ _______'Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r Priority:
[] 30 D. M 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-002F 6/23/06 08:56 SE C BP X Transferred from COC 2006-00436 1 /9106-0012-003F 6/23/06 08:39 SE C BP x Transferred from CCC 2006-00436 9106-0012-004F 6/23/06 09:32 SE C BP X Transferred from COC 2006-00436 D 2-9106-0012-005F 6/23/06 09:56 SE C BP X Transferred from COC 2006-00436 Of&9106-0012-006F 6/23/06 13:07 SE C BP X Transferred from CDC 2006-00436 6D-9106-0012-010F 6/23/06 11:08 SE C BP x Transferred from CDC 2006-00436 6x-9106-0012-013F 6/23/06 110:56 SE C BP x Transferred from COC 2006-00436  9106-0012-013FS 6/23/06 10:56 SE C BP X Transferred from COC 2006-00436 NOTES: P0 #: 002332 MSR #: 06-o?49 SSWP# NA Z LTP QA E Radwaste QA [ Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: _ Deg.UPS C LI Hand Custody Sealed?Relinquished By DateTie 2) eived By / D- ... te/Time Custody Seal"IAEA C4 i 14O li Other Intact?3) Relinquished By Date/Time "4,)'ceive-d By"Z- Bil of Lain 4 aeT Y [3 N []Bill of Lading #5) Relinquished By Date/Time  
[] 30 D. M 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-002F 6/23/06 08:56 SE C BP X Transferred from COC 2006-00436 1 /9106-0012-003F 6/23/06 08:39 SE C BP x Transferred from CCC 2006-00436 9106-0012-004F 6/23/06 09:32 SE C BP X Transferred from COC 2006-00436 D 2-9106-0012-005F 6/23/06 09:56 SE C BP X Transferred from COC 2006-00436 Of&9106-0012-006F 6/23/06 13:07 SE C BP X Transferred from CDC 2006-00436 6D-9106-0012-010F 6/23/06 11:08 SE C BP x Transferred from CDC 2006-00436 6x-9106-0012-013F 6/23/06 110:56 SE C BP x Transferred from COC 2006-00436  9106-0012-013FS 6/23/06 10:56 SE C BP X Transferred from COC 2006-00436 NOTES: P0 #: 002332 MSR #: 06-o?49 SSWP# NA Z LTP QA E Radwaste QA [ Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: _ Deg.UPS C LI Hand Custody Sealed?Relinquished By DateTie 2) eived By / D- ... te/Time Custody Seal"IAEA C4 i 14O li Other Intact?3) Relinquished By Date/Time "4,)'ceive-d By"Z- Bil of Lain 4 aeT Y [3 N []Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time '3$ 4 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 0 00 o0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00452 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556
: 6) Received By Date/Time '3$ 4 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 0 00 o0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00452 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556
________Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <843 556 8171. Attn. Cheryl Jones r Priority:  
________Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <843 556 8171. Attn. Cheryl Jones r Priority:
[i 30 D. Z 14 D. []7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-007F 6/21/06 09:32 SE C BP x Transferred from COC # 2006-00433 9106-0012-008F 6/21/06 09:00 SE C BP X Transferred from COC # 2006-00433 aq 9106-0012-012F 6/21/06 09:19 SE C BP x Transferred from COC # 2006-00433 9106-0012-014F 6/21/06 10:05 SE C BP x Transferred from COC # 2006-00433 9106-0012-OIIF 6/21/06 09:51 SE C BP X ' _ Transferred from COC #2006-00433 oi 9106-0012-015F 6/21/06 14:24 SE C BP X Transferred from COC # 2006-00433 o jZ..9106-0012-009F 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 O 9106-0012-009FS 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 al q 9106-0012-OOIF 6/23/06 09:18 SE C BP x Transferred from COC # 2006-00436 "5 NOTES: PO #: 002332 MSR #: 06-096? SSWP# NA Z LTP QA E] Radwaste QA Li Non QA Samples Shipped Via: Internal 0 Fed Ex Container El UPS Temp.: -Deg. C-- Hand Custody Sealed?YD NO I) Relinquished By Date/Time  
[i 30 D. Z 14 D. []7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-007F 6/21/06 09:32 SE C BP x Transferred from COC # 2006-00433 9106-0012-008F 6/21/06 09:00 SE C BP X Transferred from COC # 2006-00433 aq 9106-0012-012F 6/21/06 09:19 SE C BP x Transferred from COC # 2006-00433 9106-0012-014F 6/21/06 10:05 SE C BP x Transferred from COC # 2006-00433 9106-0012-OIIF 6/21/06 09:51 SE C BP X ' _ Transferred from COC #2006-00433 oi 9106-0012-015F 6/21/06 14:24 SE C BP X Transferred from COC # 2006-00433 o jZ..9106-0012-009F 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 O 9106-0012-009FS 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 al q 9106-0012-OOIF 6/23/06 09:18 SE C BP x Transferred from COC # 2006-00436 "5 NOTES: PO #: 002332 MSR #: 06-096? SSWP# NA Z LTP QA E] Radwaste QA Li Non QA Samples Shipped Via: Internal 0 Fed Ex Container El UPS Temp.: -Deg. C-- Hand Custody Sealed?YD NO I) Relinquished By Date/Time
: 2) Re ei d By Custody Seal~ 1.V-ohr4_
: 2) Re ei d By Custody Seal~ 1.V-ohr4_
7 LitE &#xfd; Other Intact?..... Z100 7 ateftime CsoY SEalN 3) Relinquished By Date/Time  
7 LitE &#xfd; Other Intact?..... Z100 7 ateftime CsoY SEalN 3) Relinquished By Date/Time
: 4) eRc d By _______ate__l-ime YE NO Bill of Lading #5) Relinquished By Date/Time  
: 4) eRc d By _______ate__l-ime YE NO Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time -g .3? 7-9  
: 6) Received By Date/Time -g .3? 7-9  
~ENC/4,.~ Ii ~SAMPLE RECEIPT & REVIEW FORM*Po R~t- ' PM wse only Client; ~~~~~SDGARCOCIWork Order:.~ ~~/,45~i~
~ENC/4,.~ Ii ~SAMPLE RECEIPT & REVIEW FORM*Po R~t- ' PM wse only Client; ~~~~~SDGARCOCIWork Order:.~ ~~/,45~i~
Line 611: Line 611:
Initials Date: O U Page 12 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-OOl Figure 1. Sample Check-in List.Date/Time Received: SDG#: Work Orderubr W 7d4'3 t (L La5 /(.4 I O rer Nubr.Shipping Cchitainer ID; 7=1 "917_ ,C hi ofCustqdy*#k-
Initials Date: O U Page 12 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-OOl Figure 1. Sample Check-in List.Date/Time Received: SDG#: Work Orderubr W 7d4'3 t (L La5 /(.4 I O rer Nubr.Shipping Cchitainer ID; 7=1 "917_ ,C hi ofCustqdy*#k-
: 1. Custody Seals. ozi.shipping container intact?.... -Yes [- No ['" 2. CustodySeals dated and signed? ,cYe-s ' [3. Chain-of-Custody record present? Yes F ] .-**4. Cooler temperature  
: 1. Custody Seals. ozi.shipping container intact?.... -Yes [- No ['" 2. CustodySeals dated and signed? ,cYe-s ' [3. Chain-of-Custody record present? Yes F ] .-**4. Cooler temperature  
-5. .Vermiculite/packing materials is: Wet [/-6 t]6." Number of samples in shipping container  
-5. .Vermiculite/packing materials is: Wet [/-6 t]6." Number of samples in shipping container
(,)... " (,2.7. /. ..7. Sample holding times exceeded?
(,)... " (,2.7. /. ..7. Sample holding times exceeded?
Yes [ No II 10. Wcrc any anomalies identified in sample receipt? Yes [] No -(" 11. ..Descriptioa of anomalie (include sample numbers):.. ......Tclphnod to q-~- .K Page 13 of 108 Health Physics Procedure ii,, GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 0 00 Pc tbj Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00434 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
Yes [ No II 10. Wcrc any anomalies identified in sample receipt? Yes [] No -(" 11. ..Descriptioa of anomalie (include sample numbers):.. ......Tclphnod to q-~- .K Page 13 of 108 Health Physics Procedure ii,, GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 0 00 Pc tbj Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00434 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
.<2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Q Priority:  
.<2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Q Priority:
[1 30 D. Z 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code _ Comment, Preservation Lab Sample ID 9106-0013-006F 6/21/06 10:33 SE C BP X .....9106-0013-003F 6/21/06 10:51 SE C BP X X 9106-0013-002F 6/21/06 10:19 SE C BP x 9106-0013-002FS 6/21/06 10:19 SE C BP X 9106-0013-010F 6/21/06 13:56 SE C BP X9106-0013-O1OFS 6/21/06 13:56 SE C BP X , 9106-0013-005F 6/21/06 14:40 SE C BP X --.9106-0013-OIIF 6/21/06 13:35 SE C BP x NOTES: PO #: 002332 MSR #: 06-i'3YSSWP#
[1 30 D. Z 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code _ Comment, Preservation Lab Sample ID 9106-0013-006F 6/21/06 10:33 SE C BP X .....9106-0013-003F 6/21/06 10:51 SE C BP X X 9106-0013-002F 6/21/06 10:19 SE C BP x 9106-0013-002FS 6/21/06 10:19 SE C BP X 9106-0013-010F 6/21/06 13:56 SE C BP X9106-0013-O1OFS 6/21/06 13:56 SE C BP X , 9106-0013-005F 6/21/06 14:40 SE C BP X --.9106-0013-OIIF 6/21/06 13:35 SE C BP x NOTES: PO #: 002332 MSR #: 06-i'3YSSWP#
NA [ LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container g Fed Ex Temp.: *jj Deg, C El UPS El Hand Custody Seale?1) Relinquished By Date/Time  
NA [ LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container g Fed Ex Temp.: *jj Deg, C El UPS El Hand Custody Seale?1) Relinquished By Date/Time
: 2) Re eived Date/Time Custody Seal Intact?iH Me ~ 114-~ // ff' E Other 3) Relinquished By Date/Time  
: 2) Re eived Date/Time Custody Seal Intact?iH Me ~ 114-~ // ff' E Other 3) Relinquished By Date/Time
: 4) Received Ay D Date/Time BillofLading#
: 4) Received Ay D Date/Time BillofLading#
_Y GE] N O Bill of Lading #5) Relinquished By Date/Time  
_Y GE] N O Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time  
-qflj -y" /1 -2 Z g'4 Health Physics Procedure/67555/..GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-.GGGR-R5 1 04-003-Attachment B-CY-00 I Major f if --Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00444 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only 0o Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
-qflj -y" /1 -2 Z g'4 Health Physics Procedure/67555/..GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-.GGGR-R5 1 04-003-Attachment B-CY-00 I Major f if --Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00444 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only 0o Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
*.2040 Savage Road, Charleston SC. 29407 .e&#xfd;843 556 8171. Attn. Cheryl Jones Priority:
*.2040 Savage Road, Charleston SC. 29407 .e&#xfd;843 556 8171. Attn. Cheryl Jones Priority:
El 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code,-.., Comment Preservation Lab Sample ID l9 9106-0013-007F 6-27-06 10:58 SE C BP X Jo 9106-0013-014F 6-27-06 09:22 SE C BP X j( 9106-0013-015F 6-26-06 15:06 SE C BP x Transferred from COG 2006-00438 , 9106-0013-001F 6-23-06 13:32 SE C BP X Transferred from COC 2006-00437 jf, 9106-0013-004F 6-23-06 13:51 SE C BP X TransferredfromCOC2006-00437" 9106-0013-009F 6-23-06 14:08 SE C BP X Transferred from COC 2006-00437 9106-0013-013F 6-23-06 14:38 SE C BP X Transferred from COC 2006-00437 9106-0013-008F 6-26-06 11:11 SE C BP X Transferred from COC 2006-00438 9106-0013-012F 6-26-06 12:35 SE C BP x Transferred from COC 2006-00438 NOTES: PO #: 002332 MSR #: 06-.'V3i SSWP# NA SLTP QA[] Radwaste QA El Non QA 1) Relinquished By Date/Tine  
El 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code,-.., Comment Preservation Lab Sample ID l9 9106-0013-007F 6-27-06 10:58 SE C BP X Jo 9106-0013-014F 6-27-06 09:22 SE C BP X j( 9106-0013-015F 6-26-06 15:06 SE C BP x Transferred from COG 2006-00438 , 9106-0013-001F 6-23-06 13:32 SE C BP X Transferred from COC 2006-00437 jf, 9106-0013-004F 6-23-06 13:51 SE C BP X TransferredfromCOC2006-00437" 9106-0013-009F 6-23-06 14:08 SE C BP X Transferred from COC 2006-00437 9106-0013-013F 6-23-06 14:38 SE C BP X Transferred from COC 2006-00437 9106-0013-008F 6-26-06 11:11 SE C BP X Transferred from COC 2006-00438 9106-0013-012F 6-26-06 12:35 SE C BP x Transferred from COC 2006-00438 NOTES: PO #: 002332 MSR #: 06-.'V3i SSWP# NA SLTP QA[] Radwaste QA El Non QA 1) Relinquished By Date/Tine
: 2) Reiv By Date/Time 3) Relinquished By Date/Time  
: 2) Reiv By Date/Time 3) Relinquished By Date/Time
: 4) Receive'd By 0 Date/Time Samples Shipped Via: Z Fed Ex 0] uPs[J Hand El Other Bill of Lading #-' to 5-7ti Izoqr Internal Container Temp.: -il Deg. C Custody Sealed?YE) Ne Custody Seal Intact?YE] NO 6 SAMPLE RECEIPT & REVIEW FORM F2 -.,M ... .OnlyI (~cunt: 1SDIGARCOCIWark Orael": ~-19 I Date Received:  
: 4) Receive'd By 0 Date/Time Samples Shipped Via: Z Fed Ex 0] uPs[J Hand El Other Bill of Lading #-' to 5-7ti Izoqr Internal Container Temp.: -il Deg. C Custody Sealed?YE) Ne Custody Seal Intact?YE] NO 6 SAMPLE RECEIPT & REVIEW FORM F2 -.,M ... .OnlyI (~cunt: 1SDIGARCOCIWark Orael": ~-19 I Date Received:  
"'A k\,k 0)a ~PM(A) Review 7 aoC fl r~~~arsovd prifr to signing)L7 Receiveu _Y: _ __4/Sample Receipt Criteria (Requird for Non-Conforming Items)Sample Receipt Criteria eq 1 I Shipping containers received intact Chic Apikable:
"'A k\,k 0)a ~PM(A) Review 7 aoC fl r~~~arsovd prifr to signing)L7 Receiveu _Y: _ __4/Sample Receipt Criteria (Requird for Non-Conforming Items)Sample Receipt Criteria eq 1 I Shipping containers received intact Chic Apikable:
Line 650: Line 650:
.9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409  
.9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409  
". ., 9106-0014-OIOF 6/12/06 14:23 SE C BP x Transferred from COC 2006-00391  
". ., 9106-0014-OIOF 6/12/06 14:23 SE C BP x Transferred from COC 2006-00391  
-9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391 9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP X Transferred from COC 2006-00385 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA E] Non QA Samples Shipped Via: I C .ifer C[]Fed Ex !T(El UPS El Hand ?ts~y ei4 1) Relinquised By Dateiime 2) c ved By Date/Time O C, Seatttc?3) Relinquished By Date/Time 4)A & ved_ By _ _te,_ _ __ e, ,- W.Bill of Lading #5) Relinquished By Date/Time  
-9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391 9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP X Transferred from COC 2006-00385 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA E] Non QA Samples Shipped Via: I C .ifer C[]Fed Ex !T(El UPS El Hand ?ts~y ei4 1) Relinquised By Dateiime 2) c ved By Date/Time O C, Seatttc?3) Relinquished By Date/Time 4)A & ved_ By _ _te,_ _ __ e, ,- W.Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time  
?,M./ 4 ..OV Health Physics Procedure I( -TrN-IA GPP-GGGR-R5104-003-Attachment B-CY-001 Major ,, I ,,,, , '--, b I .. .. .of Custody Form CDNo. 2006-00457 kConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: 1-laddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
?,M./ 4 ..OV Health Physics Procedure I( -TrN-IA GPP-GGGR-R5104-003-Attachment B-CY-001 Major ,, I ,,,, , '--, b I .. .. .of Custody Form CDNo. 2006-00457 kConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: 1-laddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
-2040 Savage Road. Charleston SC. 29407 0 843 556 81.71. Attn. Cheryl Jones Crn Priority:
-2040 Savage Road. Charleston SC. 29407 0 843 556 81.71. Attn. Cheryl Jones Crn Priority:
E] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 6(0 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 fl( 9106-0014-031F 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387 013 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 614 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387
E] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 6(0 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 fl( 9106-0014-031F 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387 013 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 614 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387
; 9106-0014-038F 6/9/06 10:59 SE C BP X Transferred from COC 2006-00397 6 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP x Transferred from COC 2006-00387 0 '9106-0014-034F 6/9/06 10:11 SE C BP X ,,,_ Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA El Non QA Samples Shipped Via: Internal Container 0g Fed Ex Temp.: __ Deg. C C' CL]C UPS Hand Custody Sealed?1) Relinquished By Date/Time  
; 9106-0014-038F 6/9/06 10:59 SE C BP X Transferred from COC 2006-00397 6 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP x Transferred from COC 2006-00387 0 '9106-0014-034F 6/9/06 10:11 SE C BP X ,,,_ Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA El Non QA Samples Shipped Via: Internal Container 0g Fed Ex Temp.: __ Deg. C C' CL]C UPS Hand Custody Sealed?1) Relinquished By Date/Time
: 2) Re Datime Custody Seal Intact?47ZE '-1.Og//t o Other 3) Relinquished By Date/Time  
: 2) Re Datime Custody Seal Intact?47ZE '-1.Og//t o Other 3) Relinquished By Date/Time
: 4) R ived By --"ae/_ime BillofLading YO NE Bill of Lading #5) Relinquished By Date/Time  
: 4) R ived By --"ae/_ime BillofLading YO NE Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time /. 4 J'- 3?Yc/
: 6) Received By Date/Time /. 4 J'- 3?Yc/
Health Physics Procedure 1 (a~A4 '/GPP-GGGR-R5104-003 -Attachment B-CY-001 Maj or* -I-v '. [Chain of Custody Form CD No. 2006-00458 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:  
Health Physics Procedure 1 (a~A4 '/GPP-GGGR-R5104-003 -Attachment B-CY-001 Maj or* -I-v '. [Chain of Custody Form CD No. 2006-00458 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:
[] 30 D. Z 14 D.EI 7 D. Container Sample Size- ,! 'Media Type &Type Sample Designation Date Time Code Code Code o e-P ra-a-me) 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387 9106-0014-009F 6/13/06 08:44 SE C BP X Transferre-from COC2006-00392-)ao 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP XTransferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-00392 9106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392
[] 30 D. Z 14 D.EI 7 D. Container Sample Size- ,! 'Media Type &Type Sample Designation Date Time Code Code Code o e-P ra-a-me) 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387 9106-0014-009F 6/13/06 08:44 SE C BP X Transferre-from COC2006-00392-)ao 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP XTransferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-00392 9106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392
,/9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: Internal Container" Fed Ex Temp.: _ Deg. C[1 ups El Hand Custody Sealed?YC N ]1) Relinquished By Date/T' e 2) Reegived By Date/Time Custody Seal Intact?3) Relinquished By Date/Tirne  
,/9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: Internal Container" Fed Ex Temp.: _ Deg. C[1 ups El Hand Custody Sealed?YC N ]1) Relinquished By Date/T' e 2) Reegived By Date/Time Custody Seal Intact?3) Relinquished By Date/Tirne
: 4) Xkeived By fate/ime BillofLadig YE NO Bill of Lading #5) Relinquished By Date/Time  
: 4) Xkeived By fate/ime BillofLadig YE NO Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 7c: 4lqyV? 4ol4 Health Physics Procedure  
: 6) Received By Date/Time 7c: 4lqyV? 4ol4 Health Physics Procedure  
/7 GPP-GGGR-R5 104-003 -Attachment B-CY-001 Major CD Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-0045 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556.
/7 GPP-GGGR-R5 104-003 -Attachment B-CY-001 Major CD Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-0045 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556.
o Project Name: H-addam Neck Decommissioning Analyses Requested Contact Name & ?hone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) T .-Li General Engineering Laboratories  
o Project Name: H-addam Neck Decommissioning Analyses Requested Contact Name & ?hone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) T .-Li General Engineering Laboratories  
.2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r, m ." Priority:  
.2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r, m ." Priority:
[130 ID. 14 D., 7 D. Container  
[130 ID. 14 D., 7 D. Container  
~~ >:Sample Size-Media Type &Type Sample Designation Date -Time Code Code Code Comment, Preservation , -9106-0014-012F 6/06/06 12:47 SE C BP X -Transferred om COC 2006-00384  
~~ >:Sample Size-Media Type &Type Sample Designation Date -Time Code Code Code Comment, Preservation , -9106-0014-012F 6/06/06 12:47 SE C BP X -Transferred om COC 2006-00384  
* '..-. .:-,... .7 D 9106-0014-018F 6/06/06 14:45 SE C BP X Transferred from COC 2006-00384 M, 9106-0014-019F 6/06/06 14:25 SE C BP X Transferred from COC 2006-00384 "d 9106-0014-001F 6/09/06 13:37 SE C BP X Transferred from COC 2006-00392 84 ., ..9106-0014-002F 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 .f .' ''9106-0014-002FS 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 9106-0014-005F 6/09/06 14:12 SE C BP X Transferred from COC 2006-00392  
* '..-. .:-,... .7 D 9106-0014-018F 6/06/06 14:45 SE C BP X Transferred from COC 2006-00384 M, 9106-0014-019F 6/06/06 14:25 SE C BP X Transferred from COC 2006-00384 "d 9106-0014-001F 6/09/06 13:37 SE C BP X Transferred from COC 2006-00392 84 ., ..9106-0014-002F 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 .f .' ''9106-0014-002FS 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 9106-0014-005F 6/09/06 14:12 SE C BP X Transferred from COC 2006-00392  
.9106-0014-006F 6/09/06 13:07 SE C BP X Transferred from COC 2006-00392 " ,J ,.9106-0014-OIIF 6/09/06 12:44 SE C BP X Transferred from COC 2006-00392  
.9106-0014-006F 6/09/06 13:07 SE C BP X Transferred from COC 2006-00392 " ,J ,.9106-0014-OIIF 6/09/06 12:44 SE C BP X Transferred from COC 2006-00392  
' .NOTES: P0 #: 002332 MSR 4: 06- SSWP#NA U LTP QA El Radwaste QA El Non QA Samples Shipped Via: 4d 1) Relinquished By Date/Time  
' .NOTES: P0 #: 002332 MSR 4: 06- SSWP#NA U LTP QA El Radwaste QA El Non QA Samples Shipped Via: 4d 1) Relinquished By Date/Time
: 2) Rec& ed By at9(Tire P" 3) Relinquished By Date/Time  
: 2) Rec& ed By at9(Tire P" 3) Relinquished By Date/Time
: 4) Lved By " il oF L....ng)elnqisedByDae/im6 RemBill of Lading #'5) Relinquished By Date/Time  
: 4) Lved By " il oF L....ng)elnqisedByDae/im6 RemBill of Lading #'5) Relinquished By Date/Time
: 6) Received By Date/Time 3q- q':
: 6) Received By Date/Time 3q- q':
Health Physics Procedure  
Health Physics Procedure  
Line 683: Line 683:
*Sample Designation Date Time Code Code Code ..-.TneComment, Preservation 200-039'9106-0014-003F 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 4, c 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396  
*Sample Designation Date Time Code Code Code ..-.TneComment, Preservation 200-039'9106-0014-003F 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 4, c 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396  
,, ""a 9106-0014-008FS 6/14/06 07:34 SE C BP ] X Transferred from COC 2006-00396_Y  
,, ""a 9106-0014-008FS 6/14/06 07:34 SE C BP ] X Transferred from COC 2006-00396_Y  
-"._nt 01 nQ -_n1 A -0 1 AT nd A InlT a n .AP X Transferred from COC 2006-00396 I. .Other Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major CD t0.Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 I Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:  
-"._nt 01 nQ -_n1 A -0 1 AT nd A InlT a n .AP X Transferred from COC 2006-00396 I. .Other Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major CD t0.Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 I Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:
[] 3013. E 14 D. [] 7 D.Comment, Preservation , Jnple&#xa2; I , D Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 , : ,: Date Samples Shipped Via: Z Fed Ex El uPs M Hand-F- Other Bill of Lading #7;t 4qfo 391-i 1 e1 SAPLERECEIPT  
[] 3013. E 14 D. [] 7 D.Comment, Preservation , Jnple&#xa2; I , D Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 , : ,: Date Samples Shipped Via: Z Fed Ex El uPs M Hand-F- Other Bill of Lading #7;t 4qfo 391-i 1 e1 SAPLERECEIPT  
& REVIEW FORM 0 1_5 Client: 12L DG/ARCOC/Work Order: Date Rec ed: PM(A) Review (ensure non-coaforon are resoved prior to signing): Received By: ,3D(Sample Receipt Criteria P [ Z Comments/Qualifiers (R ui for Non-Confrming it I Shipping containers received intact I Circle A"'lic"ble:
& REVIEW FORM 0 1_5 Client: 12L DG/ARCOC/Work Order: Date Rec ed: PM(A) Review (ensure non-coaforon are resoved prior to signing): Received By: ,3D(Sample Receipt Criteria P [ Z Comments/Qualifiers (R ui for Non-Confrming it I Shipping containers received intact I Circle A"'lic"ble:
Line 698: Line 698:
Telephoned to: :O. * -" .A__uB.: r., ". ..Page 26 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O0i Figure 1. Sample.Check-in List.DatelTime Received:
Telephoned to: :O. * -" .A__uB.: r., ". ..Page 26 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O0i Figure 1. Sample.Check-in List.DatelTime Received:
7 0 9.SDG#- ~,~'0  o 3 Work Order Number0~9~I9?-39,76 Shipping C'.ntainer ID&#xfd; 4 chain of custody'#
7 0 9.SDG#- ~,~'0  o 3 Work Order Number0~9~I9?-39,76 Shipping C'.ntainer ID&#xfd; 4 chain of custody'#
26 L).. !. Custody Seals odsbipping container intact?.._  
26 L).. !. Custody Seals odsbipping container intact?.._
[t 2. Custody Seals dated and signed? Yes 'rNo [ ].3. Chain-of-Custo'.y record present? Yes [T1No [1 4. Cooler temperature  
[t 2. Custody Seals dated and signed? Yes 'rNo [ ].3. Chain-of-Custo'.y record present? Yes [T1No [1 4. Cooler temperature
:2 ;6'S. Vermiculite/packing materials is: Wet [--Dry t, ]6 'Number of samples in shipping containere.  
:2 ;6'S. Vermiculite/packing materials is: Wet [--Dry t, ]6 'Number of samples in shipping containere.  
"" 7. Sample holding times exceeded?
"" 7. Sample holding times exceeded?
Line 720: Line 720:
Tclephoned to_;_ Dy -Page 30of 108 Health Physics ProcedUI?'-,',,,;('-/_
Tclephoned to_;_ Dy -Page 30of 108 Health Physics ProcedUI?'-,',,,;('-/_
GPP-OGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics ProceduJ?.~~.~y/
GPP-OGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics ProceduJ?.~~.~y/
GPP-GGGR-R5 1 04-003-Attachment B-CY-00 1 Major ILf# I ~~*Uf I -Chain of Custody Form No. 2006-00443 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning "Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Z- n (Z z Priority:  
GPP-GGGR-R5 1 04-003-Attachment B-CY-00 1 Major ILf# I ~~*Uf I -Chain of Custody Form No. 2006-00443 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning "Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Z- n (Z z Priority:
[1- 30 D. Z 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 1 9106-0015-022F 6-27-06 16:24 SE C BP X X 9106-0015-023F 6-27-06 16:03 SE C BP X X 9106-0015-024F 6-27-06 15:42 SE C BP X X 9106-0015-026F 6-27-06 14:58 SE C BP X _ X 9106-0015-027F 6-27-06 15:17 SE C BP X x: 9106-0015-028F 6-27-06 14:31 SE C BP X X 1 9106-0015-018F 6-27-06 17:18 SE C BP X X g 9106-0015-025F 6-27-06 16:43 SE C BP X x 9106-0015-021F 6-27-06 17:01 SE C BP X NOTES: PO #: 002332 MSR #: 06-105J ; SSWP# NA 0 LTP QA[] Radwaste QA[D Non QA 1) Relinquished By Date/Time  
[1- 30 D. Z 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 1 9106-0015-022F 6-27-06 16:24 SE C BP X X 9106-0015-023F 6-27-06 16:03 SE C BP X X 9106-0015-024F 6-27-06 15:42 SE C BP X X 9106-0015-026F 6-27-06 14:58 SE C BP X _ X 9106-0015-027F 6-27-06 15:17 SE C BP X x: 9106-0015-028F 6-27-06 14:31 SE C BP X X 1 9106-0015-018F 6-27-06 17:18 SE C BP X X g 9106-0015-025F 6-27-06 16:43 SE C BP X x 9106-0015-021F 6-27-06 17:01 SE C BP X NOTES: PO #: 002332 MSR #: 06-105J ; SSWP# NA 0 LTP QA[] Radwaste QA[D Non QA 1) Relinquished By Date/Time
: 2) R ived Date/Time 3) Relinquished By Date/Time  
: 2) R ived Date/Time 3) Relinquished By Date/Time
: 4) Received BY J Date/Time Samples Shipped Via: E Fed Ex I UPS Ml Hand El Other Bill of Lading #?-qO 1 5- -/I/Jot Internal Container Temp.: 1I Deg. C Custody Sealed?YO N7" Custody Seal Intact?YO NO Health Physics Procedure/ bi -7, , /.GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major&W', U L(,':- I -' '~~~~~Chain of Custody Form n.20-04 Connecticut Yankee Atomic Power Company No. 2006-00448 362 Injun Hollow Road, East Hampton, CT 06424 o860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested MR. .Contact Name & Phone: -"-" : Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State) p General Engineering Laboratories 2040 Savage Road. Charleston SC, 29407 0 843 556 8171. Attn. Cheryl Jones co COO Priority:
: 4) Received BY J Date/Time Samples Shipped Via: E Fed Ex I UPS Ml Hand El Other Bill of Lading #?-qO 1 5- -/I/Jot Internal Container Temp.: 1I Deg. C Custody Sealed?YO N7" Custody Seal Intact?YO NO Health Physics Procedure/ bi -7, , /.GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major&W', U L(,':- I -' '~~~~~Chain of Custody Form n.20-04 Connecticut Yankee Atomic Power Company No. 2006-00448 362 Injun Hollow Road, East Hampton, CT 06424 o860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested MR. .Contact Name & Phone: -"-" : Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State) p General Engineering Laboratories 2040 Savage Road. Charleston SC, 29407 0 843 556 8171. Attn. Cheryl Jones co COO Priority:
E] 30 D. Z 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designatioa Date Time Code Code Code ... .Comment, Preservation ... e .9106-0015-011F 6-28-06 14:39 SE C BP X X _,_______-___.,_..___..._
E] 30 D. Z 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designatioa Date Time Code Code Code ... .Comment, Preservation ... e .9106-0015-011F 6-28-06 14:39 SE C BP X X _,_______-___.,_..___..._
Line 730: Line 730:
9106-0015-020F 6-28-06 07:59 SE C BP X X ":_______"_
9106-0015-020F 6-28-06 07:59 SE C BP X X ":_______"_
_-___"-_,__."-
_-___"-_,__."-
NOTES: PO #: 002332 MSR #: 06- 2o 3 7- S SWP# NA SLTP QA E] Radwaste QA[: Non QA 1) Relinquished By Date/3ime 2)ycivdcB' Date/Time 3) Relinquished By Date/Time  
NOTES: PO #: 002332 MSR #: 06- 2o 3 7- S SWP# NA SLTP QA E] Radwaste QA[: Non QA 1) Relinquished By Date/3ime 2)ycivdcB' Date/Time 3) Relinquished By Date/Time
: 4) Received By Q Date/Time Samples Shipped Via: Z Fed Ex E1 UPS[] Hand E] Other Bill of Lading #q7//0 5-.- (tl 2 Y ,'YE NE Health Physics Procedure,/GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00447 362 Injun Hollow Road, East Hampton, CT 06424 0860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: 'omm S-*.: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
: 4) Received By Q Date/Time Samples Shipped Via: Z Fed Ex E1 UPS[] Hand E] Other Bill of Lading #q7//0 5-.- (tl 2 Y ,'YE NE Health Physics Procedure,/GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00447 362 Injun Hollow Road, East Hampton, CT 06424 0860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: 'omm S-*.: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories  
% --2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:E]
% --2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:E]
30 D. N 14 D. L1 7 D. Container Sample Size-Media Type &Type Sample Desigation Date Time Code Code Code .Comment, Preservation Labp- ei-p 9106-0015-OOIF 6-28-06 13:36 SE C BP X X o 9106-0015-002F 6-28-06 14:15 SE C BP X X -. .11 9106-0015-003F 6-28-06 13:15 SE C BP X X 0 9106-0015-004F 6-28-06 12:54 SE C BP X 2 9106-0015-005F 6-28-06 15:47 SE C BP X X : .:- .f 9106-0015-006F 6-28-06 16:10 SE C BP X X 9106-0015-007F 6-28-06 11:33 SE C BP X X .9106-0015-OOF 6-28-06 11:10 SE C BP X X ta 9106-0015-009F 6-28-06 10:25 SE C BP X X F!9106-0015-OIOF 6-28-06 15:17 SE C BP X X -" ."-NOTES: PO #: 002332 MSR#: 06-/J357 SSWP#NA SLTP QA[I Radwaste QA El Non QA I) Relinquished By Date/Time Date/Time 3) Relinuihd By-Date/Tm 4)" 2eceiedht-Date/Time 3) Relinquished By Date/Time  
30 D. N 14 D. L1 7 D. Container Sample Size-Media Type &Type Sample Desigation Date Time Code Code Code .Comment, Preservation Labp- ei-p 9106-0015-OOIF 6-28-06 13:36 SE C BP X X o 9106-0015-002F 6-28-06 14:15 SE C BP X X -. .11 9106-0015-003F 6-28-06 13:15 SE C BP X X 0 9106-0015-004F 6-28-06 12:54 SE C BP X 2 9106-0015-005F 6-28-06 15:47 SE C BP X X : .:- .f 9106-0015-006F 6-28-06 16:10 SE C BP X X 9106-0015-007F 6-28-06 11:33 SE C BP X X .9106-0015-OOF 6-28-06 11:10 SE C BP X X ta 9106-0015-009F 6-28-06 10:25 SE C BP X X F!9106-0015-OIOF 6-28-06 15:17 SE C BP X X -" ."-NOTES: PO #: 002332 MSR#: 06-/J357 SSWP#NA SLTP QA[I Radwaste QA El Non QA I) Relinquished By Date/Time Date/Time 3) Relinuihd By-Date/Tm 4)" 2eceiedht-Date/Time 3) Relinquished By Date/Time
: 4) Received by DJ* Iate/Time-Samples Shipped Via: ER Fed Ex E]ups LI Hand LI Other Bill of Lading #-4 Wo y H/ I (2 a 0&~t~dy S~YIntact?  
: 4) Received by DJ* Iate/Time-Samples Shipped Via: ER Fed Ex E]ups LI Hand LI Other Bill of Lading #-4 Wo y H/ I (2 a 0&~t~dy S~YIntact?  
-YtJ N0 Health Physics Procedure)/-~Ac/~GPP-GGGR-R5 104-003-Attachment B-CY-001 Major I (~' I '~ ~"W I C Chain of Custody Form roNo. 2006-00468 CConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 0 ~860-267-2556-  
-YtJ N0 Health Physics Procedure)/-~Ac/~GPP-GGGR-R5 104-003-Attachment B-CY-001 Major I (~' I '~ ~"W I C Chain of Custody Form roNo. 2006-00468 CConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 0 ~860-267-2556-  
-Project Name: Haddam Neck Decommissioning Analyses Requested  
-Project Name: Haddam Neck Decommissioning Analyses Requested  
..-.. ,.... ..oo Contact Name & Phone: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 .: .843 556 8171. Attn. Cheryl Jones ..Priority:j3 0D.~ 14 D.EFI7 D. Container Sampl Size-Media Type &Type Sample Desipation Date Time Code Code Code Preservation i 9106-0015-005FS 6-28-06 15:47 SE C BP X X 9106-0015-012FS 6-28-06 10:58 SE C BP X -x -l l 9106-0015-018FS  27-06 17:18 SE C BP X X NOTES: PO #: 002332 MSR#: 06-1(93f SSWP#NA Z LTP QA 0 Radwaste QA E] Non QA 1) Relinquishei By Date/T*ne  
..-.. ,.... ..oo Contact Name & Phone: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 .: .843 556 8171. Attn. Cheryl Jones ..Priority:j3 0D.~ 14 D.EFI7 D. Container Sampl Size-Media Type &Type Sample Desipation Date Time Code Code Code Preservation i 9106-0015-005FS 6-28-06 15:47 SE C BP X X 9106-0015-012FS 6-28-06 10:58 SE C BP X -x -l l 9106-0015-018FS  27-06 17:18 SE C BP X X NOTES: PO #: 002332 MSR#: 06-1(93f SSWP#NA Z LTP QA 0 Radwaste QA E] Non QA 1) Relinquishei By Date/T*ne
: 2) ceivdB Date/Time 3) Relinquished By Date/time  
: 2) ceivdB Date/Time 3) Relinquished By Date/time
: 4) Receive&By "3 Date/Time Samples Shipped Via: Z Fed Ex ElUPS[] Hand El Other Bill of Lading #'4110 S- 1 2f'TC Custody SeCA dustdy~el~nact?,  
: 4) Receive&By "3 Date/Time Samples Shipped Via: Z Fed Ex ElUPS[] Hand El Other Bill of Lading #'4110 S- 1 2f'TC Custody SeCA dustdy~el~nact?,  
-- SAMPLE RECEIPT & REVIENh FORM I C77 K tC~/ i~1IC AI(n 7~4~,/ Pi _ , I r Client: C'X.n, .-r or mate Received:  
-- SAMPLE RECEIPT & REVIENh FORM I C77 K tC~/ i~1IC AI(n 7~4~,/ Pi _ , I r Client: C'X.n, .-r or mate Received:  
Line 769: Line 769:
9106-0001-112A
9106-0001-112A
____ SE C BP X- -_ _______ ______9106-0001-112B SE C BP X -9106-0001-112C SE C BP X ____ __:__._______
____ SE C BP X- -_ _______ ______9106-0001-112B SE C BP X -9106-0001-112C SE C BP X ____ __:__._______
NOTES: PO #: 002332 MSR #:06- #70 SSWP# NA U LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Iht onfaiier[ Fed Ex -en)p D:g, D] UPS ;"; " .-[] Hand :ustody Seled 9 1) Relinquished By Date/Time  
NOTES: PO #: 002332 MSR #:06- #70 SSWP# NA U LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Iht onfaiier[ Fed Ex -en)p D:g, D] UPS ;"; " .-[] Hand :ustody Seled 9 1) Relinquished By Date/Time
: 2) Received By D te/Time :: adySea ,, i:-..; -:-: :.. /..-....-:.Other
: 2) Received By D te/Time :: adySea ,, i:-..; -:-: :.. /..-....-:.Other
: 3) Relinquished By Date/Time  
: 3) Relinquished By Date/Time
: 4) Received By Date/Time V_--.___ W__,_Bill of Lading #-5) Relinquished By Date/Time  
: 4) Received By Date/Time V_--.___ W__,_Bill of Lading #-5) Relinquished By Date/Time
: 6) Received By Date/Time 79;/ p]-3o .1 " "'
: 6) Received By Date/Time 79;/ p]-3o .1 " "'
* Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major CD 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested  
* Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major CD 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested  
-"'.Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones n.Priority:
-"'.Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones n.Priority:
30 D. 14 D. 7 D. 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation  
30 D. 14 D. 7 D. 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation
: Lf,;pId 1151 Code Code Code 9106-0001-I 12D SE C BP X -. .NOTES: PO 9: 002332 MSR ~:06- irV3 SSWP# NA U LP QA ElRadwaste QA F1 Non QA Samples Shipped Via.:o~i~SFed Ex. eg ElUPS E] Hand ... .ll " 'l 1) Relinquished By Date~fime  
: Lf,;pId 1151 Code Code Code 9106-0001-I 12D SE C BP X -. .NOTES: PO 9: 002332 MSR ~:06- irV3 SSWP# NA U LP QA ElRadwaste QA F1 Non QA Samples Shipped Via.:o~i~SFed Ex. eg ElUPS E] Hand ... .ll " 'l 1) Relinquished By Date~fime
: 2) Received By Date/Time CadySeal ii 9 irt 9~'( ~ ~ / c/ /5 CLL~~ ~ ltist ~ED Otherti 3) Relinquished By Date/Time  
: 2) Received By Date/Time CadySeal ii 9 irt 9~'( ~ ~ / c/ /5 CLL~~ ~ ltist ~ED Otherti 3) Relinquished By Date/Time
: 4) Received By Date/Time
: 4) Received By Date/Time
_________Y)
_________Y)
N Bill of Lading 5) Relinquished By Date/Time  
N Bill of Lading 5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time  
~ ~ y~_ _ _ _ _ _ _ _ _ ' .a .,, : :
~ ~ y~_ _ _ _ _ _ _ _ _ ' .a .,, : :
Line 1,188: Line 1,188:
.Colorado--Connecticut Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas____Kentucky
.Colorado--Connecticut Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas____Kentucky
..Maryland-Massachusetts SMichigan Nevada New Jersey New York North Carolina North Carolina Drinking W North Dakota Oklahoma---- Pennsylvania South Carolina Tennessee Texas US. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 88-0651 42D0904046 6115CA 1-C...... .--- enngLabs .. ..PH-0169 NFESC4I13 W--L6-5J ....E87156 E871 56(FLJNELAP)
..Maryland-Massachusetts SMichigan Nevada New Jersey New York North Carolina North Carolina Drinking W North Dakota Oklahoma---- Pennsylvania South Carolina Tennessee Texas US. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 88-0651 42D0904046 6115CA 1-C...... .--- enngLabs .. ..PH-0169 NFESC4I13 W--L6-5J ....E87156 E871 56(FLJNELAP)
N/A 200029 C-SC-) I-E-10332 270 M-SC012 9903 SC 12-SCO02 f 1 501 233 45709 R-158 9904 68-485 10120001/10585001/10120002 02934 TX213-2006A S-52597 N/A..... 8037697376 GEL N/A 00151 C223 4 Chain of Custody And Supporting Documentation i I -5 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00511 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones U0 C Priority:  
N/A 200029 C-SC-) I-E-10332 270 M-SC012 9903 SC 12-SCO02 f 1 501 233 45709 R-158 9904 68-485 10120001/10585001/10120002 02934 TX213-2006A S-52597 N/A..... 8037697376 GEL N/A 00151 C223 4 Chain of Custody And Supporting Documentation i I -5 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00511 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones U0 C Priority:
[] 30 D. Z 14 D. [] 7 D. Container K- O ""'5Z_ f.Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample MI)9106-0006-005A 8/8/06 14:35 SE C BP X X Transferred from COC N 2006-00488 9106-0006-005B 8/8/06 15:08 SE C BP x X Transferred from COC # 2006-00488 9106-0006-005C 8/9/06 07:46 SE C BP X X Transferred from COC # 2006-00307 9106-0006-005D 8/9/06 08:18 SE C BP X X Transferred from COC # 2006-00307 NOTES: PO#: 002332 MSR #: 06-116O SSWP#NA Z LTP QA E] Radwaste QA El Non QA 1) Relinquished By 3 A M C-4or& "-Date/Time&#xfd;-Za4-0&#xfd;/1 3'(i Samples Shipped Via: Z Fed Ex[Ikips El Hand El Other Bill of Lading #"-00o 4 Internal Container Temp.: __ Deg. C Custody Sealed?YO- NO Custody Seal Intact?YE NO 3) Relinquished By Date/Time I Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00512 362 Irijun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C C Priority:
[] 30 D. Z 14 D. [] 7 D. Container K- O ""'5Z_ f.Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample MI)9106-0006-005A 8/8/06 14:35 SE C BP X X Transferred from COC N 2006-00488 9106-0006-005B 8/8/06 15:08 SE C BP x X Transferred from COC # 2006-00488 9106-0006-005C 8/9/06 07:46 SE C BP X X Transferred from COC # 2006-00307 9106-0006-005D 8/9/06 08:18 SE C BP X X Transferred from COC # 2006-00307 NOTES: PO#: 002332 MSR #: 06-116O SSWP#NA Z LTP QA E] Radwaste QA El Non QA 1) Relinquished By 3 A M C-4or& "-Date/Time&#xfd;-Za4-0&#xfd;/1 3'(i Samples Shipped Via: Z Fed Ex[Ikips El Hand El Other Bill of Lading #"-00o 4 Internal Container Temp.: __ Deg. C Custody Sealed?YO- NO Custody Seal Intact?YE NO 3) Relinquished By Date/Time I Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00512 362 Irijun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C C Priority:
E] 30 D. Z] 14 D.E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0005-01OA 8/9/06 09:03 SE C BP X X Transferred from COC # 2006-00489 9106-0005-010B 8/9/06 09:33 SE C BP x x Transferred from COC # 2006-00489 9106-0005-OIOC 8/9/06 10:04 SE C BP X X Transferred from COC # 2006-00489 9106-0005-OIOD 8/9/06 10:56 SE C BP x x Transferred from COC # 2006-00489 NOTES: PO #: 002332 MSR#: 06- 1!40 SSWP# NA Z LTP QA El Radwaste QA El Non QA 1) Relinquished By ime 2) ceived By ..D te/Time 3) Relinquished By DatefTime ceived By Samples Shipped Via: 0 Fed Ex E0 UPs El Hand[ Other Bill of Lading #Sq 00 4631 4Z3 Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YoI NO]
E] 30 D. Z] 14 D.E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0005-01OA 8/9/06 09:03 SE C BP X X Transferred from COC # 2006-00489 9106-0005-010B 8/9/06 09:33 SE C BP x x Transferred from COC # 2006-00489 9106-0005-OIOC 8/9/06 10:04 SE C BP X X Transferred from COC # 2006-00489 9106-0005-OIOD 8/9/06 10:56 SE C BP x x Transferred from COC # 2006-00489 NOTES: PO #: 002332 MSR#: 06- 1!40 SSWP# NA Z LTP QA El Radwaste QA El Non QA 1) Relinquished By ime 2) ceived By ..D te/Time 3) Relinquished By DatefTime ceived By Samples Shipped Via: 0 Fed Ex E0 UPs El Hand[ Other Bill of Lading #Sq 00 4631 4Z3 Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YoI NO]
Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 I Major I.Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00513 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddamn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones un Cn Priority:  
Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 I Major I.Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00513 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddamn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones un Cn Priority:
[] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0014-033A 8/11/06 07:58 SE C BP X X Transferred from COC # 2006-00493 C9106-0014-033B 8/11/06 08:24 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033C 8/11/06 08:45 SE C BP x x Transferred from COC # 2006-00493 9106-0014-033D 8/11/06 09:16 SE C BP X X Transferred from COC # 2006-00493 NOTES: PO #: 002332 MSR #: 06-1160 SSWP# NA Z LTP QA E3 Radwaste QA El Non QA Relinquished By Date/Time ,&#xa2;-q 13  2)/ived By A I'hl~, J&#xfd;2,44_iz Samples Shipped Via:[ Fed Ex 13 uPs[] Hand 1] Other Bill of Lading #9e'Q 40Y'q 644q Internal Container Temp.: _ Deg. C-Custody Sealed?YOI No Custody Seal Intact?YD NEI Date/Time 3) Relinquished By Date/Time  
[] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0014-033A 8/11/06 07:58 SE C BP X X Transferred from COC # 2006-00493 C9106-0014-033B 8/11/06 08:24 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033C 8/11/06 08:45 SE C BP x x Transferred from COC # 2006-00493 9106-0014-033D 8/11/06 09:16 SE C BP X X Transferred from COC # 2006-00493 NOTES: PO #: 002332 MSR #: 06-1160 SSWP# NA Z LTP QA E3 Radwaste QA El Non QA Relinquished By Date/Time ,&#xa2;-q 13  2)/ived By A I'hl~, J&#xfd;2,44_iz Samples Shipped Via:[ Fed Ex 13 uPs[] Hand 1] Other Bill of Lading #9e'Q 40Y'q 644q Internal Container Temp.: _ Deg. C-Custody Sealed?YOI No Custody Seal Intact?YD NEI Date/Time 3) Relinquished By Date/Time
: 4) R e&-ed By -7 lap, Date/Time Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00520 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn ci d Priority:E]30D.
: 4) R e&-ed By -7 lap, Date/Time Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00520 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn ci d Priority:E]30D.
14D.[117D.
14D.[117D.

Revision as of 09:06, 13 July 2019

Final Status Survey Final Report Phase IV, Appendix A14, Survey Unit Release Record 9106-0014, Discharge Canal
ML063410430
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/21/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0014
Download: ML063410430 (390)


Text

Book 15 of 17 1 F Final Status Survey Final Report Phase IV Appendix A14 Survey Unit Release Record 9106-0014, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0014 Prepared By: ___ __ __Reviewed By.//ngineer AEngine, Approved By: -j Technical Support Manager Date: -//- /Z -0 Date: .-1(-0;o Date: "4I7 i e Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

.................................................................

3 2. CLASSIFICATION BASIS .......................................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ....................................................

5 4. SURVEY DESIGN ....................................................................................

9 5. SURVEY IMPLEMENTATION

...............................................................

13 6. SURVEY RESULTS ...............................................................................

14 7. QUALITY CONTROL .............................................................................

16 8. INVESTIGATIONS AND RESULTS ......................................................

16 9. REMEDIATION AND RESULTS ............................................................

17 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ....................

18 11. DATA QUALITY ASSESSMENT (DQA) ................................................

18 12. A NO M A LIES ..........................................................................................

19 13. CO NCLUSIO N ........................................................................................

19 14. ATTACHMENTS

....................................................................................

20 14.1 Attachment 1 -Figures (8 pages including cover)14.2 Attachment 2 -Sample and Statistical Data (361 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 1. SURVEY UNIT DESCRIPTION Survey Unit 9106-0014 (Discharge Canal) is designated as Final Status Survey (FSS) Class 1 and consists of approximately 1,870 m2 (0.46 acres) of water covered sediment in an area located approximately 0.16 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes.

The survey unit is bounded as follows: Survey Unit 9106-000lis to the north (called north as oriented with the north to south flow of the Connecticut River), Survey Unit 9521 is to the east, Discharge Canal Survey Unit 9106-0002 is to the south and land Surface Area 9520 is to the west. The survey unit comprises the canal sediments to the depth of three feet from the top of the sediment layer or the original construction depth and it extends up the canal banks to the mean high water level.The survey unit comprises the canal sediments to the depth of three (3) feet from the top of the sediment layer or the original construction depth. This survey unit is bounded by reference coordinates E006 through E010 and by S074 through S080 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0014 as Class I in June 2006.The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the 1OCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement," c) Historic and current survey records review, d) Visual inspections and a "walk-down." e) Formal or informal interviews with cognizant personnel.

A review of the IOCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. Several events indicated the Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side system leakage events, contamination found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None of the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00).

These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.This area was initially a portion of then Class 2 Survey Unit 9106-0001.

Upon reviewing the FSS data for this area it was determined that at least one sample exceeded the seventeen (17) mrem/yr DCGL for the area. This required that the area be reclassified as two (2) Class 1 survey units. In order to optimize the amount of area covered by Class 1 surveys, a portion of Survey Unit 9106-0002 was also included into the southern most area of the two (2) newly designated Class 1 survey units. This was done and the newly created survey unit was designated 9106-0014.

An initial characterization was performed in April and May of 2004 to obtain the necessary data of sufficient data quality for final status survey (FSS)planning purposes.

Fifteen (15) samples were obtained by biased sampling from five (5) locations throughout the area. The samples were analyzed off-site by gamma spectroscopy and with radiochemical analyses for Sr-90 and Tritium.Hard-to-Detect analyses were also conducted on one of the 15 samples. The only plant-related dosimetrically significant radionuclides identified in the samples were Cs-137 and Cobalt-60.

All sample analysis results were below the (ten) 10 mrem/yr target level. Cobalt-60 accounted for the majority of the dose in these samples with a maximum concentration of 1.04 pCi/g.A final characterization survey was performed in May 2006. Samples were collected and analyzed on-site by gamma spectroscopy.

Fifteen (15) sediment samples from fifteen (15) locations were collected and analyzed for radioactive materials.

All of the samples were analyzed by gamma spectroscopy.

A summary of the results are presented in Table 1 below.Revision 0 4 Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 1 -Basic Statistical Quantities for Cs-137 and Co-60 from the Characterization Survey Parameter Cs-137 (pCi/g) Co-60 (pCi/g)Minimum Value: 2.15E-02 1.03E-03 Maximum Value: 1.57E+00 2.25E+00 Mean: 5.96E-01 6.15E-01 Median: 6.39E-01 3.81E-01 Standard Deviation:

4.96E-01 6.97E-01 NOTE: The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCilg for Co-60; these are used in conjunction with the unity rule to achieve seventeen (17)mrem/yr TEDE The FSS Engineer performed a visual inspection and walk-down during June 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class I (refer to Section 3).3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5. 1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0014 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario.

Consequently, the soil DCGLs are directly applied to the canal sediment media The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation 1: HTotal=Hsoil (sediment)

+ HExisting GW + HFuture GW The total dose under the LTP criteria is 25 mrem/yr TEDE from all three components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the groundwater dose values discussed above.This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). The dose contribution from existing groundwater is bounded to be less than two (2) mrem/yr TEDE, based on field data.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater is zero (0) mrem/yr TEDE.Equation 2: 19 mrem/yrTotal=

17 mrem/yrsoil+2 mrem/yrExisting GW+O mreml/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Table 2 -Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1) Base Case Soil Operational DCGL Required MDC DCGL (pCi/g) (2) (pCi/g) (3) (pCi/g) (4)H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.10E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+0 1 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs- 134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu- 152 1.01 E+0 I 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O 1 2.01E+01 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mremlyr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Initial characterization was performed in April of 2004 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.

The LTP (by way of equation 5-31) states that if residual radioactivity exists in an isolated area of elevated activity in addition to residual radioactivity distributed relatively uniformly across a survey unit, the unity rule will be used to ensure the total dose is within the release criterion.

This is demonstrated in equation 3.Equation 3 (LTP Equation 5-31):Celevated

<-(-+ <1 DCGLW (AreaFactor) x DCGL W Where:= Average concentration outside the elevated area, C elevated = Average concentration in the elevated area.A separate term will be used in Equation 3.0 for each elevated area in a survey unit.Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.

Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is seventeen (17) mrem/yr TEDE, as discussed in Section 3 of this Release Record.The DQO process determined that Cs-137 and Co-60 were the radionuclides of concern (refer to Section 2). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) were considered in the survey design.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs".Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected.

This process was applied to analysis data for this survey unit.The Elevated Measurement Comparison (EMC) applies to this survey unit since it is a Class I area and discrete, elevated areas of contamination are expected.A description of the application of the EMC is provided in section 3.0.The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected.

The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.633 to maintain the relative shift (A/cr) in the range of 1 and 3. The resulting relative shift was 1.3. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of MARSSIM in support of the Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. For statistical purposes, the survey design specified twenty-one (21)samples were required.

However, due to a special requirement to double the number of statistical samples in this section of the discharge canal, resulting from an agreement with the State of Connecticut Department of Environmental Protection (CTDEP), this number needed to be doubled to forty-two (42)sediment core samples for non-parametric statistical testing.The grid pattern and locations of the sediment samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14,"Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 3 -Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9106-0014-OO1F 236196.66 669170.85 9106-0014-002F 236196.66 669194.31 9106-0014-003F 236176.34 669088.74 9106-0014-005F 236176.34 669159.12 9106-0014-006F 236176.34 669182.58 9106-0014-007F 236156.02 669077.01 9106-0014-008F 236156.02 669100.47 9106-0014-009F 236156.02 669123.93 9106-0014-OIOF 236156.02 669147.39 9106-0014-011F 236156.02 669170.85 9106-0014-012F 236135.70 669041.82 9106-0014-013F 236135.70 669065.28 9106-0014-014F 236135.70 669088.74 9106-0014-015F 236135.70 669112.20 9106-0014-016F 236135.70 669135.66 9106-0014-017F 236135.70 669159.12 9106-0014-018F 236115.39 669030.09 9106-0014-019F 236115.39 669053.55 9106-0014-020F 236115.39 669077.01 9106-0014-021F 236115.39 669100.47 9106-0014-022F 236115.39 669123.93 9106-0014-023F 236115.39 669147.39 9106-0014-024F 236095.07 669018.36 9106-0014-025F 236095.07 669041.82 9106-0014-026F 236095.07 669065.28 9106-0014-027F 236095.07 669088.74 9106-0014-028F 236095.07 669112.20 9106-0014-029F 236095.07 669135.66 9106-0014-030F 236074.75 669006.63 9106-0014-031F 236074.75 669030.09 9106-0014-032F 236074.75 669053.55 9106-0014-033F 236074.75 669077.01 9106-0014-034F 236074.75 669100.47 9106-0014-035F 236074.75 669123.93 9106-0014-036F 236054.43 669041.82 9106-0014-037F 236054.43 669065.28 9106-0014-038F 236054.43 669088.74 9106-0014-039F 236054.43 669112.20 9106-0014-040F 236034.12 669053.55 9106-0014-041F 236034.12 669077.01 9106-0014-042F 236034.12 669100.47 9106-0014-043F 236145.72 669151.52 The sample location designations of Table 3 because of the necessity to relocate a sample are not sequentially inclusive due to the accessibility of an Revision 0 I1I Revision 0 11 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD original sample location.

Sample location 9106-0005-004F was found to be on dry land. Consequently, it was randomly re-located using the VSP software to a new location designated as 9106-0014-043F.

Seven (7) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Five (5) of the Seven (7) samples were randomly selected using the Microsoft Excel"RAND" function.

The two (2) samples exhibiting the highest observed radionuclide concentrations by gamma analyses were also selected.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," required the collection of five (5) samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RAND" function.

The number of quality control samples exceeded the 5%requirement as specified by the LTP.Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.Table 4 -Synopsis of the Survey Design (1)Feature Design Criteria Basis Survey Unit 1,870 m 2 Based on AutoCAD-LT and Visual Land Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 42 sigma was 0.484 the LBGR was set to Measurements(3) 0.367 to maintain Relative Shift in the range of I and 3, Relative Shift was 1.3 Grid Spacing 7.17 m Based on triangular grid Design DCGL 3.16 pCi/g Cs-137 To achieve ten (10) mrem/yr TEDE 1.52 pCi/g Co-60 To achieve seventeen (17) mrem/yr TEDE (2) to demonstrate compliance with DCGL 2.59 pCi/g Co-60 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 5.38 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.59 pCi/g Co-60 criteria for a Class 1 survey unit Level (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)Revision 0 12 Revision 0 12 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 5. SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Surveys, Inc.(OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten feet or less).A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample locations were accomplished using a GPS interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples." Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.The forty-two (42) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3,"Collection of Sample Media for Final Status Survey" and FSS design.Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Seven (7) samples (9106-0014-003F, 9106-0014-01 IF, 9106-014-012F, 9106-0014-018F, 9106-0014-033F, 9106-0007-37F and 9106-0014-038F) were selected for HTD radionuclide analysis by the off-site laboratory.

The implementation of quality control measures included the collection of five (5) split samples at locations (9106-0014-002F, 9106-0014-008F, 9106-0014-018F, 9106-0014-027F and 9106-0014-028F) for comparative analysis by the off-site laboratory.

Revision 0 13 Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The laboratory analyzed the forty-two (42) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Sr-90 was analyzed by liquid scintillation analyses.

All analyses were performed to the required MDC.Cs-137 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in thirty-seven (37) and Co-60 was positively identified in thirty-four (34) of the forty-two (42) samples.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed a total seven (7) samples for full HTD analysis as required by the sample plan, and for gamma results that indicated additional testing was warranted.

The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC.Several of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.One of the sample results (9106-0014-033F) exceeded the Operational DCGL and required further investigation.

A summary of the sample results is provided in Table 5.Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCi/g pCi/g Operational DCGL ()9106-0014-OO1F 1.41E-03 8.94E-03 3.71E-03 9106-0014-002F 3.61E-03 2.52E-03 1.64E-03 9106-0014-003F 3.95E-06 1.15E-02 4.44E-03 9106-0014-005F 5.45E-02 2.88E-02 2.12E-02 9106-0014-006F 2.42E-01 2.67E-01 1.48E-01 9106-0014-007F 1.61E-01 2.17E-01 1.14E-01 9106-0014-008F 9.66E-02 1.60E-01 7.97E-02 9106-0014-009F 1.64E-01 5.99E-02 5.36E-02 9106-0014-OIOF 3.63E-01 2.38E-01 1.59E-01 9106-0014-01 IF 3.56E-02 5.76E-03 8.84E-03 9106-0014-012F 1.15E+00 1.45E+00 7.74E-01 Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 5- Summary of Sediment Sample Results Fraction of the Sample Number pCs/g 137g COperational pCi/g pCi/g DCGL (')9106-0014-013F 2.19E-01 1.36E-01 9.32E-02 9106-0014-014F 1.47E-02 1 .13E-02 7.10E-03 9106-0014-015F 5.85E-02 1.68E-01 7.57E-02 9106-0014-016F 6.89E-02 1.05E-01 5.33E-02 9106-0014-017F 5.52E-01 5.93E-01 3.32E-01 9106-0014-018F 2.93E-01 8.95E-01 4.OOE-01 9106-0014-019F 7.49E-01 1.32E+00 6.49E-0 1 9106-0014-020F 5.94E-02 6.60E-02 3.65E-02 9106-0014-021F 1.17E-01 4.50E-01 1.95E-01 9106-0014-022F

1. 15E-01 2.89E-02 3.25E-02 9106-0014-023F 4.53E-02 4.90E-02 2.73E-02 9106-0014-024F 2.41E-02 -1.63E-03 3.85E-03 9106-0014-025F 5.50E-01 1.36E+00 6.27E-01 9106-0014-026F 1.20E-01 1.52E-01 8.1 OE-02 9106-0014-027F 1.66E-0 1 4.69E-01 2.12E-01 9106-0014-028F 8.72E-02 1.86E-01 8.80E-02 9106-0014-029F 5.80E-02 9.38E-02 4.70E-02 9106-0014-03OF 3.89E-02 2.49E-02 1.68E-02 9106-0014-031 F 3.85E-02 3.90E-02 2.22E-02 9106-0014-032F 2.55E-01 3.98E-01 2.01E-01 9106-0014-033F 1.36E+00 2.07E+00 1.05E+00 9106-0014-034F 3.OOE-01 1.01 E+00 4.46E-01 9106-0014-035F 2.OOE-01 2.49E-01 1.33E-01 9106-0014-036F 7.85E-02 3.41E-01 1.46E-0 I 9106-0014-037F 3.26E-01 1.23E+00 5.35E-01 9106-0014-038F 3.47E-01 1.60E+00 6.82E-01 9106-0014-039F 3.77E-01 1.36E+00 5.95E-01 9106-0014-040F 9.62E-02 4.36E-01 1.86E-01 9106-0014-041 F 4.76E-02 1.47E-01 6.56E-02 9106-0014-042F 1.52E-01 6.66E-01 2.85E-01 9106-0014-043F 1.29E-0 1 1.08E-01 6.57E-02 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve a seventeen (17) mrem/yr TEDE The off-site laboratory also processed a total of seven (7) samples for HTD analysis as required by the sample plan. Five (5) of the seven (7) samples were statistical locations that were selected at random. The remaining two (2)samples, were selected for additional testing based on having the highest dose equivalence, based on gamma spectroscopy measurements.

A number of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).

However, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 7. QUALITY CONTROL The five (5) split samples taken for QC were analyzed by the off-site laboratory.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24,"Split Sample Assessment for Final Status Survey. " For all QC split samples, there was an acceptable level of agreement.

The sample analysis vendor, GEL, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS One (1) sample results was found to exceed the operational DCGL of seventeen (17) mrem/yr, exceeding the investigation level from Table 4. Thus investigations were required to determine compliance with Equation 3 of Section 3.The first step in assessing compliance with the EMC unity rule is to determine the area extent of the elevated measurement region. This was done by taking investigation samples at a distance of two (2) meters in each of the (4) four compass directions (north, south, east and west) about the elevated sample point (9106-0014-033F).

When these sample results were reported to be below the investigation levels specified in Table 4, the area was determined to be bounded.The investigation survey was based on original coordinates (those in the Final Status Survey Plan) for the FSS of 9106-0014-033F.

However, when these coordinates were later compared against field logs, it was determined that sampling location was 2.6 meters away from that specified in the sample plan.Consequently, the region was not completely bounded by the samples taken for investigation.

To remedy this situation, samples 9106-0014-026F, 9106-014-027F and 9106-0014-32F were used in conjunction with 9106-0014-033B and 9106-0014-033C to bound the extent of the elevated area. The area of the elevated measurement location (also the area used to determine area factors) was conservatively calculated by assuming the area was a circle with a radius equal to the most distant bounding measurement location.

This was done using actual GPS log data. This was the most prudent approach since maneuvering the sampling vessel to obtain samples within such closely spaced locations imposes unusually high positioning precision.

Table 6 provides sample measurement location information (in NAD 1927) and distances from sample location 9106-0014-033F.Revision 0 16 Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Table 6 -Investigation Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting Distance from location 9106-0014-033F 236080.09 669070.38 9106-0014-033F (m)9106-0014-033B 236079.67 669077.22 2.09 9106-0014-033C 236074.91 669068.61 1.67 9106-0014-026F 236094.51 669067.28 4.50 9106-0014-027F 236088.10 669082.62 4.46 9106-0014-032F 236073.08 669058.21 4.28 Area (M2) 62.53 Since the bounded area was determined to be 62.5 m 2 , the Area Factor (AF)values from Table 5-5 of the LTP for 75 m2 was conservatively applied to determine the DCGLEMC for each nuclide. With this information, it is possible to assess compliance with the EMC rule. This is demonstrated in Table 7.Table 7-Investigation Results Sample Number Cs-137 Co-60 Fraction of pCi/g pCi/g the Operational Area Factor DCGL (75 m 2) 3.08 1.47 DCGLEMC 16.6 3.81 9106-0014-033B 8.62E-01 9.44E-01 5.25E-01 9106-0014-033C 6.09E-01 9.16E-0 1 4.67E-0 1 9106-0014-026F 1.20E-01 1.52E-01 8.1 OE-02 9106-0014-027F 1.66E-01 4.69E-0 1 2.12E-0 1 9106-0014-032F 2.55E-01 3.98E-01 2.01E-01 EMC Comparison for 9106-0014-033F (Equation 3)C elevated 5.62E-01 8.25E-01 EMC unity C elevated -15 3.67E-01 4.27E-01 fraction 3 DCGL 3.63E-02 1.54E-01 1.90E-01 C elevated -(DCGLEMC 2.21 E-02 1.12E-0 1 1.34E-01 Total For the Survey Unit (must be <1 in accordance with the LTP (Equation 5-31) & Equation 3 of this report) 3.24E-01 9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Revision 0 17 Revision 0 17 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning.

It is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used to demonstrate compliance with the LTP and CTDEP criteria is seventeen (17) mrem/yr TEDE as discussed in Section 2 of this Release Record.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment." The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion, thus, the null hypothesis is rejected.Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a need to change the original LBGR in order to maintain the number of samples at forty-two (42) to meet the Operational DCGL. However, the value of LBGR is not a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criterion with adequate power as required by the DQOs The range of the data, about 4.12 standard deviations, was not unusually large.The difference between the mean and median was 46.3% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.62.The survey area had one elevated measurement location, which was evaluated using the unity EMC test. This resulted in a passing value of 0.324, which is significantly below unity.Revision 0 18 Revision 0 18 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES The anomalies associated with the positioning of investigation samples relative to the area being bounded is discussed in Section 8. This anomaly had no consequences with regards to the conclusion or other findings of this report.13. CONCLUSION Survey Unit 9106-0014 has demonstrated compliance with the dose based, unrestricted release criterion.

The sample data passed the Sign Test and the null hypothesis was rejected.

The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Reclassification and remediation of this survey unit was not required.Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as a Class I survey unit.An EMC calculation was performed, for the discrete area (62.5 m2 around sample location 9106-0014-033F, in accordance with the LTP equation 5-31 and equation 3 of this report. The results indicated that the area was less than unity. No further action is warranted.

See Tables 6 & 7 of this report for specific information with regard to the EMC calculation.

The dose contribution from sediment in this survey unit is 3.5 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is bounded by two (2) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 5.5 mrem/yr Total Effective Dose Equivalent (TEDE).Revision 0 19 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD 14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 20 Revision 0 20 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 1 Figures (7 pages) 0 450 00 Coardkidwmv NAD27C7wdc SAW AW yW Figure 1 Connecticut Yankee Atomic Power Company 9106-0014 Final Status Survey Design Dat": November 2006 Revision:

0 9522-0004 9106-0002 20 40 EC= I== Fw('0 #15 Nofts Cbardimaw xwain NAD27ornedcut state Plan SytM=0 #14 0#22 0#13 0#21 0#29'%0 0#28 9106-0014 Ddv &e 0#27 buccraaib Sampl Locadw 06-0001 0#26 0#34 0#25 0#33 0#38 Connecticut Yankee Atomic Power Company 9106-0014 Final Status Swvey Desin 9522-0004 9106-0002 L~z~0 20 40 , I= Feet Notme 0.0585 cowniinateammil NAD27Cbmecdoet StAW Pimi Sjymm 101 @0.0147 9106-0014$ D.*ig &ampie Lomaw 0 0.0594 11.15 0 0.749 06 0.166& nceil &-LOWOSample, 06-0001 0 0.120 0 1.36 Ocesum-137resulta am gimis pc~g.,cticut Yankee Atomic Power C 9106-0014 Final Status Survey Cesium-137Posting Plot 9522-0004 9106-0002 0 20 40 , = = IFeet*"0 10.16 17C ~0.0113~0.136 0.450 Noftc Coord&Wn tr. iaw NAD27 CbowneWiu Sitat Plane SyW1nz 9106-0014 Dl*S.le 0.066 1.45 1.1.32 0.469 IS &ccmp-le wl 06-0001 0.152 1.01.895 2.07 Cobak-6O ramuf M shivenmpig.

1f 1.60.6 Connecticut Yankee Atomic Power Company 9106-0014 Final Status Survey Cobalt-60 Posting Plot 9522-0004 9106-0002 0 20 40* .............

.. I F ee t.Notsa£Cardinaft xain NAD27 fbmactcut SAW~PlAnSyuM 9106-0014 DCGL w 6-0001 LOM&O UAr DCMmw Am Uod far DCGaw.QCkulatio DOCM Conmocticut Yankee Atomic Power Company 9106-0014 Elevated Measurement Comparison (FMC) Calculaion Data 9522-0004 9106-0002 0 20 40 i Feet Nofto Cbordinwame in NAD27 Cbnnectcut Sbwt Plane System 0 9106-0014 On;W -wi LocutioExcedin DCiLw 06-0001 DaIL ma, Calcuation DCGLwm ( FW~9= raction oftki DCGL de to Cesium-137 Connecicut Yankee Atomic Power Company 9106-0014 Fltevad Mesu =n t Cbmp o (E1ML CQalculaon Data for Czwsiw-13 7

9522-0004 K 9106-0002 20 40 Notes CboMwdats amin NAD27Conecdcut Stt Systvm 0 9106-0014 Loctim ERAc f DCGLw I,-'16-0001 B dbgSal Cakulation O Boodazyoafthe Ae Used for DCGLaw Cakudtion (M"WW = Rucon of the DCUGL duc to Cobs&-60 Connecticut Yankee Atomic Power Company 9106-0014 Elevatd Measuement Compmaison (EMC) Calculadon Date for Cobalt-60 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2 Sample and Statistical Data DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2a Sample Data (334 Pages)

Table of Contents G eneral Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

5 Radiological Analysis .........................................................

18 Sample Data Summary ......................................................

43 Q uality C ontrol D ata ...........................................................

144 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 167014 SDG: MSR #06-0988 July 25, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on July 13, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID 167014001 167014002 167014003 167014004 167014005 167014006 167014007 167014008 167014009 Client Sample ID 9106-0014-021F 9106-0014-030F 9106-0014-032F 9106-0014-043F 9106-0014-OIOF 9106-0014-016F 9106-0014-022F 9106-0014-013F 9106-0014-024F 2

167014010 167014011 167014012 167014013 167014014 167014015 167014016 167014017 167014018 167014019 167014020 167014021 167014022 167014023 167014024 167014025 167014026 167014027 167014028 167014029 167014030 167014031 167014032 167014033 167014034 167014035 167014036 167014037 167014038 167014039 167014040 167014041 167014042 167014043 167014044 167014045 167014046 167014047 9106-0014-025F 9106-0014-031F 9106-0014-017F 9106-0014-023F 9106-0014-035F 9106-0014-039F 9106-0014-042F 9106-0014-034F 9106-0014-029F 9106-0014-009F 9106-0014-028F 9106-0014-028FS 9106-0014-036F 9106-0014-040F 9106-0014-041F 9106-0014-04IFS 9106-0014-012F 9106-0014-019F 9106-0014-0OIF 9106-0014-002F 9106-0014-002FS 9106-0014-005F 9106-0014-006F 9106-0014-007F 9106-0014-008F 9106-0014-008FS 9106-0014-014F 9106-0014-015F 9106-0014-020F 9106-0014-026F 9106-0014-027F 9106-0014-027FS 9106-0014-033F 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Items of Note: There are no items of note.3 Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Forty-two soil samples were analyzed for FSSGAM.Five soil samples were analyzed for FSSALL.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171 ° Fax4843) 766-1178 ° www.gel.com Chain of Custody and Supporting Documentation 5

Health Physics Procedure Mc-,w 4-1 GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00456 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested UOl Contact Name & Phone: 61omments:, Jack McCarthy 860-267-2556 Ext. 3924 -." : Analytical Lab (Name, City, State) ., General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <843 556 8171. Attn. Cheryl Jones .", Priority:

E] 30 D. E] 14 D. E] 7 D. Container Sample Size- ..Media Type &Type ComnPeevto Lab ,. " , Sample Designation Date Time Code Code Code Comment, Preservation Lab Sale'lD 9106-0014-021F 6/15/06 10:50 SE C BP X Transferred from COC 2006-00407 9106-0014-030F 6/15/06 11:20 SE C BP X Transferred from COC 2006-00407 9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409 P.. :- ..9106-0014-OIOF 6/12/06 14:23 SE C BP X Transferred from COC 2006-00391 9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391

......9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP xI Transferred from COC 2006-00385

_V .. -1 1 ..-______4 Vv NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA Li Radwaste QA[] Non QA 1) Relinquished By Date ime 2) R eved By ) --- Date/Time 3) Relinquished By Date/Time

4) ved By "atefime Samples Shipped Via:[ Fed Ex Li uPs Li Hand Li Other Bill of Lading #flZ 4?sV 3W-7 Terfp.: E~g. C tustody~Sealed?

Th't N'7.CUstody" Sea~lIntact?

Y 2, K 5) Relinquished By Date/Time 6) Received By Date/Time 1 1 Health Physics Procedure/U GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 5 W I ~ I Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00457 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0<843 556 8171. Attn. Cheryl Jones Priority:E]

30 D. Z 14 D. R 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID) 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 9106-0014-03 IF 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387

[ 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387 9106-0014-038F 6/9/06 10:59 SE C BP _ X Transferred from COC 2006-00387 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 0l oj a 6i 0 M I/91 06-001 4-042F 6/9/06 09.53 SE C BP x Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP 9106-0014-034F 6/9/06 10:11 SE C BP x Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA F1 Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: __ Deg. C 0C'ts F] UPS El Hand Custody Sealed?YO NO 1) Relinquished By Date/Time

2) Re d By Dat ime Custody Seal Intact?J/I~P1Ei~c~~

~ /tO~/LcO 7Other 3) Relinquished By Date/Time -ate/ime BillofLading

_Y_ NO Bill of Lading #R 5) Relinquished By Date/Time

6) Received By Date/Time / 4 qsV Health Physics Procedure I I -I-(V Tullf '/ -GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00458 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C Priority:

[] 30 D. E 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID Xt 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387)t '9106-0014-009F 6/13/06 08:44 SE C BP X Transferred from COC 2006-00392 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP X Transferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-003929106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392 9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA E LTP QA El Radwaste QA E Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: ___ Deg. C EI uPs 0 Hand Custody Sealed?YE NO 1) Relinquished By Date/Time

2) Rec ived By Date/Time Custody Seal Intact?A-11 P C*P_ -r- :L- 0 2 'V lI Other 3) Relinquished By Date/Tim e 4) K keived By Efate/! ime Bill of LadiY N E Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 7., 0, Health Physics Procedure i(;- 4 /GPP-GGGR-R5 104-003-Attachiment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-0045!

362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested L.b.W;, ,. ,., .A Contact Name & Phone: , Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories

, 2040 Savage Road. Charleston SC. 29407 -.843 556 8171. Attn. Cheryl Jones Priority:

El 30 D. N 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Coment, Preservation

-., Salpl 9106-0014-012F 6/06/06 12:47 SE C BP X Trnsere from CO, .0038 9106-0014-018F 6/06/06 14:45 SE C BP X -2 9106-0014-019F 6/06/06 14:25 SE C BP X- -9106-0014-O01F 6/09/06 13:37 SE C BP X --9106-0014-005F 6/09/06 14:42 SE C BP X Transferred from COC 2006-00384 9106-0014-OOIF 6/09/06 13:07 SE C BP X Transferred from COC 2006-00392 9106-0014-002FS 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392

,,:. ..... 't 9106-0014-005F 6/09/06 14:12 SE C BP X -rnfre fro CO_ -00 039.9106-0014-006F 6/09/06 13:07 SE C BP X -rnfre -ro -206009 9106-0014-01 IF 6/09/06 12:44 SE C BP __ Xrnfre -ro -O -00039 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via:

Z Fed Ex El UPS Other Health Physics Procedure mGPP-GGGR-RC 104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company No. 2006-0046(362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning A-nalyses R-'questede Lap ....Contact Name & Phone: omet Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 Con 843 556 8171. Attn. Cheryl Jones , , : : Priority:

El 30 D. 2 14 D. []7 D. Container

..Sample Size- , Media Type &Type Pervto b 0nplC , Sample Designation Date Time Code Code Code Comment, Preservation

-.,-P- I 9106-0014-0031 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396

-.9106-0014-008FS 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396

[.......9106-0014-014F 6/14/06 10:23 SE C BP X Transferred from COC 2006-00396 , NOTES: PO #: 002332 MSR #: 06- SSWP# NA 0 LTP QA Lj Radwaste QA [I Non QA Samples Shipped Via: e n g,~ Fed Ex Tj.: 0I UPS E] Hand a/; td0 e 1) Relinquished By Dat /Time 2) Recei d By / jvme p'tLE ý' i11cIit Other :.>3) Relinquished By Date/Time 4)'ý i d B-y hate/Time

________-.________

5) Relinquished By GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Health Physics Procedure//,;qW/zf I ~&~' * -~ I f'Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

RI 30 D. 0 14 D. FI 7 D.Date Comment, Preservation Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 Samples Shipped Via: Fed Ex IU PSn F1H andL n Other Bill of Lading #7 ýA 1 4 ?3_0 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-00O Figure 1. Sample Check-in List.Date/Time Received:

? )Work Order Number: l (,0 1 q Shipping Cdntainer ID: Chain of Custody # ..1. Custody Seals on shipping container intact?- Yes fi f I [2. Custody Seals dated and signed? Yesj[ o ].3. Chain-of-Custody record present? Yes :No 1].4. Cooler temperature

5. Vermiculite/packing materials is: Wet [,ry t' I" 6. Number of samples in shipping container:

_._"_"_"__

__7. Sample holding times exceeded?

Yes []10. Were any anomalies identified in sample receipt? Yes [ ] No 11. .Description Of anomalies, (include sample numbers):..,. ber .: .Telcphoncd to: On .By. -.12 Connecticut Yankee Statement of Work for Analytical Lab Services .CY.ISC-SOW-OOI Figure 1. Sample Cheqkin List.Dateflime Receved:" 1) .-SDG# __Work Order Number.___________________

Shiping C. itiner I chain of custody # -6Z)"-" I "Custody Seals otfshipping container intact?.. .Yes [, 1 io [-2. Custody Seals dated and signed? " Yes" INo [I].3. Chain-of-Custody r*eord Yes [f 0 o [ 3 4. Cooler e rature 17 W...Vermiculite/packing materials is: ..Wet [--]"Dry t\ .5. oe ('7. Samplc.holding timeW exceeded? .Yes [-8. *ao .es.e-, -~ Jzardlabels

_.. ~y Seats -.appropriate sample labels 9. Samples ar..*n good condiion -leaking.* .... o......broka -. --hlay; 9dr bubbles 10. We any-anomalies Widtified in S.nple recip? .*...'

of anomalies (include sample nue):-13 Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-001

...cY-lsc-SOw-ool m Figure 1. Si Datefime Received:

4//Q ...* SDG#. u'A Work Order Nt r_." Shippin Cdtainr I. Custody Seals oi" shipping container intac 2. Custody Seals dated and signed?3. Chain-of-Custody rcord p.resent?"-4. Cooler temperature 5 .Verniculite/packing materials is: 6. Number ofsamples in shipping container'.

7. Sample holding times ex6e'eed?umple Check-in List.,-079-8 Chain of Cusi t-Yes I.W-j0io*Ycs+<Nof Yes c4b I I Wet F.1rytK,.4.Yes [No []' ! '8.Samples have.-'.-tape Jazard labels-._.ea seals a....ppropriate sample labels I 9. Samples ar"".Ziigood condition*

..ekn._.. broku ." " .. ...-.hae air bubbles 10. Were ~an~alifreceipt? Yes[ No J* f.. .D srp onl" ,alies,,(incud

"___.. ..____'_ __"__ "__ __1 DescrtOn ofano.,,J,, ude sample numbers):.ampl" Custod"azL'"ab:rat"y..

14a Tcc. oe ..oWy .,,

Connecticut Yankee .CY-SC-SOW--00 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List Date/Time Received: SDG#: Work Order Number:_ _ _ _ _ _ _ _ _Shipping Cdntainer ID.:, LR/ J/ Chain of Custody# ., -CV' ,:. 1. Custody Seals. o shipping container intact?.. -Yes o [ ]2. Custody Seals dated and. signed? Yes' [,/No []3. Chain-of-Custody record present? Yes [/ No 4. Cooler temperature

5. ..Vermiculite/packing materials is: Wet [,4Dry t'% " 6. Numberof samples in shipping container:

....__7. Sample holding times exceeded?

Yes J4,No [ ]8. Samples have."ý ._._hazard labels_Z_ custody seals " --appropriate sample labels 9. Samples are:..in good condition leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ J No 11. .Description of anomalies (include sample numbers): Telephoned to:. "On lBy is-Connecticut Yankee Statement of Work for Analytical Lab Services Cy-ISC-SOW-O00 Figure 1. Sample Check-in List.Date/rime Received: SDG#: AýSpu~ 69 Work Order Number:______________________

________Shipping Container ID: 19 " Chain of Custody 4 O6, # -A g)c /". Custody Seals ori shipping container intact?. -Yes ý-go []2. Custody Seals dated and signed? Yes*,,-No

[I..3. Chain-of-Custody record prpsent? Yes D.no (1 4. Cooler temperature

,9- .5. Vermiculite/packing materials is: Wet t\ I 6.: Number of samples in shipping container

//7. Sample holding tims exce'eded?

Yes "-r1o 8. Samples have:'als hazard labels Uftnnr~nSamplei Ia~L 9. Samples are.'good condition.. broken-.. leaking~___have air bubbles 10. Were anyanomalie.sidentifled in sample receipt?Yes [, No! ..Description of anomalies (include sample numbers):$ample. CustodiaW/aboratory Telephoned to._____________


By.16 7 ~SAMPLE RECEIPT & REVIEW FORM 00 Olt0lt" PM use oinly 11.', nf /Worn Olrder: I Client: Y//P D ate R ec" -ed: [P (A) Review (ensureI ..-co.fort.ll.

it are resolved p r r o i g Received By: Vi Sample Receipt Criteria Comments/Qualifiers (Requir d for Non-Conformingi Shipping containers received intact Circle Applicable:

seals broken damaged co" iner leaking containe r (_e scribe)and sealed?Samples requiring cold Circle Coolan # ice bags blue ice dry ice none oter describe)2 preservation within (4 +1- 2 C)?Record preservation method.Chain of custody documents included with shipment?Sample containers intact and Circle Applicable:

seals broken damag ontainer leaking container other (describe) sealed?Samples requiring chemical Sample ID's. containers affected observed p1: preservation at proper pH?VOA vials free of headspace Sample ID's and co ai affected: 6(defined as < 6mm bubble)? 0" Are Encore containers present?7 (If yes. immediately deliver to VOA laboratory)

Samples received within holding 1i a tests affleCted 8.time?Sample ID's on COC match ID's sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected: 10& time on bottles?______________

Number of containers receiv Sample ID's affec1ed match number indicated COC?COC form is propr signed in 12 relin uished/rec eriýd sections?

_Air Bill acking #'s, &14 Addit nal Comments T i RSORADReceipt#

Suspected Hazard Information

  • If > x2 area background is observed on samples identified as "non-regulated/non-radioactive, contact the Radiation Safety group for further investigation.

A Radiological Classification?

-Maximum Counts Observed*:'

B PCB Regulated?

Comments: Shipped as DOT Hazardous C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#:[_PM (or PMA) review of Hiazard classitication:

Initials ate:.LI U/

RADIOLOGICAL ANALYSIS 18 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 167014 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548404 547923 547819 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136020 1201136021 1201136022 1201136023 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014043(9106-0014-038F)

Sample Duplicate (DUP)167014043(9106-0014-038F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry 19 All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014043 (9106-0014-038F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Batch was recounted due to a high Matrix Spike recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 20 Product: Alphaspec Pu, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548405 547923 547819 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136024 1201136025 1201136026 1201136027 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01IF 9106-0014-003F Method Blank (MB)167014043(9106-0014-038F)

Sample Duplicate (DUP)167014043(9106-0014-038F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014043 (9106-0014-038F).

21 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548406 547923 547819 22 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136028 1201136029 1201136030 1201136031 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014043(9106-0014-038F)

Sample Duplicate (DUP)167014043(9106-0014-038F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014043 (9106-0014-038F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

23 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 548621 Prep Batch Number: 547812 24 Sample ID 167014001 167014002 167014003 167014004 167014005 167014006 167014007 167014008 167014009 167014010 167014011 167014012 167014013 167014014 167014015 167014016 167014017 167014018 167014019 167014020 1201136614 1201136615 1201136616 Client ID 9106-0014-021F 9106-0014-030F 9106-0014-032F 9106-0014-043F 9106-0014-01OF 9106-0014-016F 9106-0014-022F 9106-0014-013F 9106-0014-024F 9106-0014-025F 9106-0014-031F 9106-0014-017F 9106-0014-023F 9106-0014-035F 9106-0014-039F 9106-0014-042F 9106-0014-034F 9106-0014-029F 9106-0014-009F 9106-0014-028F Method Blank (MB)167014001(9106-0014-021 F) Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014001 (9106-0014-021F).

25 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The relative percent difference between samples 1201136615 (9106-0014-021F) and 167014001 (9106-0014-021F) for Ac-228, Co-60 and TI-208 did not meet duplication criteria.

However, when a relative error ratio is calculated, precision is shown at 1.27 for Ac-228, 2.86 for Co-60 and 1.42 for TI-208.Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to high peak-width.

Bismuth-212 1201136615 UI Data rejected due to interference.

Cesium-134 167014017 Manganese-54 167014001 UI Data rejected due to low abundance.

Cesium-134 167014002 167014008 167014015 Method/Analysis Information 26 Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 167014021 167014022 167014023 167014024 167014025 167014026 167014027 167014028 167014029 167014030 167014031 167014032 167014033 167014034 167014035 167014036 167014037 167014038 167014039 167014040 1201136623 1201136624 1201136625 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 548622 547815 Client ID 9106-0014-028FS 9106-0014-036F 9106-0014-040F 9106-0014-041F 9106-0014-041FS 9106-0014-012F 9106-0014-019F 9106-0014-001F 9106-0014-002F 9106-0014-002FS 9106-0014-005F 9106-0014-006F 9106-0014-007F 9106-0014-008F 9106-0014-008FS 9106-0014-014F 9106-0014-015F 9106-0014-020F 9106-0014-026F 9106-0014-027F Method Blank (MB)167014021(9106-0014-028FS)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).27 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014021 (9106-0014-028FS).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 28 Qualifier UI UI Reason Data rejected due to interference.

Data rejected due to low abundance Data rejected due to no valid peak.Analyte Sample Manganese-54 167014031 Actinium-228 167014021 1201136624 Cesium-134 167014026 167014028 167014031 167014033 167014034 167014036 167014040 Thallium-208 167014039 Cesium-134 167014032 UI Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 167014041 167014042 167014043 167014044 167014045 167014046 167014047 1201136626 1201136627 1201136628 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 548625 547819 Client ID 9106-0014-027FS 9106-0014-033F 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014041(9106-0014-027FS)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)29 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014041 (9106-0014-027FS).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 339793 was generated due to Container scanning event for custody missed. 1. Container scanning event for custody missed: The analyst did not scan the samples into the batch prior to analysis, however the samples did remain in their custody at all times. 167014 041,042,043,044,045,046,047

1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Additional Comments 30 The relative percent difference (1201136627 (9106-0014-027FS) and 167014041 (9106-0014-027FS))

for Pb-214 did not meet the duplication criteria.

However, when a relative error ratio is calculated, precision is shown at 2.2181.Oualifier information Qualifier Reason UI UI Data rejected due to interference.

Data rejected due to low abundance Analyte Europium-155 Cesium- 134 Sample 167014043 167014045 167014041 167014042 167014045 Method/Analysis Information Product: GFPC, Sr9O, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548637 547923 547819 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136660 1201136661 1201136662 1201136663 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014045(9106-0014-018F)

Sample Duplicate (DUP)167014045(9106-0014-018F)

Matrix Spike (MS)Laboratory Control Sample (LCS)31 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014045 (9106-0014-018F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis The batch was reweighed and recounted due to low recoveries.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.32 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: Analytical Batch Number: Sample ID 167014043 167014044 167014045 167014046 167014047 1201134546 1201134547 1201134548 1201134549 DOE EML HASL-300, Tc-02-RC Modified 547825 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014045(9106-0014-018F)

Sample Duplicate (DUP)167014045(9106-0014-018F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014045 (9106-0014-018F).

33 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548412 547923 547819 34 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136040 1201136041 1201136042 1201136043 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014045(9106-0014-018F)

Sample Duplicate (DUP)167014045(9106-0014-018F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014045 (9106-0014-018F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

35 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-i, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 548413 547923 547819 Sample ID 167014043 167014044 167014045 167014046 167014047 1201136044 1201136045 1201136046 1201136047 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014045(9106-0014-018F)

Sample Duplicate (DUP)167014045(9106-0014-018F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.36 Calibration Information:

Calibration Information All initial andcontinuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014045 (9106-0014-018F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 37 Product: Analytical Method: Analytical Batch Number: Sample ID 167014043 1670.14044 167014045 167014046 167014047 1201134745 1201134746 1201134747 1201134748 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 547901 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014043(9106-0014-038F)

Sample Duplicate (DUP)167014043(9106-0014-038F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014043 (9106-0014-038F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.38 Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201134746 (9106-0014-038F), 167014044 (9106-0014-037F) and 167014047 (9106-0014-003F) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 167014043 167014044 167014045 167014046 167014047 1201134749 1201134750 1201134751 1201134752 EPA EERF C-01 Modified 547902 Client ID 9106-0014-038F 9106-0014-037F 9106-0014-018F 9106-0014-01 IF 9106-0014-003F Method Blank (MB)167014044(9106-0014-037F)

Sample Duplicate (DUP)167014044(9106-0014-037F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.39 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 167014044 (9106-0014-037F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 167014045 (9106-0014-018F) was recounted due to results more negative than the MDA results. Sample 167014045 (9106-0014-018F) was recounted due to a suspected false positive.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The blank, 1201134749 (MB), did not meet the detection limit due to keeping the blank volume consistent with the other sample aliquots.

All other samples met the detection limits.Qualifier information Manual qualifiers were not required.Certification Statement 40 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

(-5;i&41 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 339793 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 28-JUL-06 Radiochemistry Specifications Process Instrument Type: Test I Method: Matrix Type: Client Code: GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID: Sample Numbers: 548625 See Below Potentially affected work order(s)(SDG):

167014(MSR#06-0988)

Application Issues: Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. Container scanning event for custody missed: The analyst did not 1. The error has been corrected and the analyst has been instructed on scan the samples into the batch prior to analysis, however the samples the proper scanning procedures.

did remain in their custody at all times.167014 041,042,043,044,045,046,047 Originator's Name: Jimmy Hartley Quality Review: Data Validator/Group Leader: Lesley Anderson 28-JUL-06 28-JUL-06 Director: Page 1 42 SAMPLE DATA

SUMMARY

43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0988 GEL Work Order: 167014 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-021F 167014001 SE 15-JUN-06 13-JUL-06 Client 18.7%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.574 +/-0.127 Americium-241 U 0.00885 +/-0.052 Bismuth-212 0.314 +/-0.172 Bismuth-214 0.418 +/-0.073 Cesium-134 U 0.033 +/-0.0236 Cesium-137 0.117 +/-0.0287 Cobalt-60 0.450 +/-0.0518 Europium-152 U -0.0131 +/-0.0354 Europium-154 U 0.0169 +/-0.0391 Europium-155 U 0.049 +/-0.0423 Lead-212 0.498 +/-0.0576 Lead-214 0.494 +/-0.0725 Manganese-54 UI 0.00 +/-0.0342 Niobium-94 U 0.000664 +/-0.0127 Potassium-40 9.10 +/-0.771 Radium-226 0.418 +/-0.073 Silver-108m U 0.0108 +/-0.0118 Thallium-208 0.179 +/-0.032 0.0426 0.0498 0.0967 0.022 0.0158 0.0117 0.0102 0.0313 0.0341 0.0404 0.0197 0.0228 0.0116 0.0113 0.102 0.022 0.011 0.0118+/-0.127+/-0.052+/-0.172+/-0.073+/-0.0236+/-0.0287+/-0.0518+/-0.0354+/-0.0391+/-0.0423+/-0.0576+/-0.0725+/-0.0342+/-0.0127+/-0.771+/-0.073+/-0.0118+/-0.032 0.0904 0.103 0.204 0.0463 0.0332 0.0247 0.0224 0.0654 0.0735 0.0833 0.0407 0.0476 0.0246 0.0239 0.223 0.0463 0.023 0.0249 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1329 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-021F Project: YANK01204 Sample ID: 167014001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-03OF 167014002 SE 15-JUN-06 13-JUL-06 Client 13.2%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.911 +/-0.135 Americium-241 U -0.0203 +/-0.113 Bismuth-212 0.631 +/-0.242 Bismuth-214 0.806 +/-0.088 Cesium-134 UI 0.00 +/-0.0297 Cesium-137 0.0389 +/-0.0185 Cobalt-60 U 0.0249 +/-0.0173 Europium-152 U 0.0224 +/-0.0434 Europium-154 U 0.0111 +/-0.051 Europium-155 U 0.0706 +/-0.0659 Lead-212 0.926 +/-0.058 Lead-214 0.986 +/-0.0768 Manganese-54 U 0.00594 +/-0.019 Niobium-94 U 0.00881 +/-0.0151 Potassium-40 11.1 +/-0.700 Radium-226 0.806 +/-0.088 Silver-108m U -0.0041 +/-0.0146 Thallium-208 0.319 +/-0.0354 0.0443 0.0913 0.117 0.0269 0.0198 0.0137 0.0163 0.0405 0.0435 0.0502 0.0254 0.0253 0.0149 0.0133 0.148 0.0269 0.0129 0.015+/-0.135+/-0.113+/-0.242+/-0.088+/-0.0297+/-0.0185+/-0.0173+/-0.0434+/-0.051+/-0.0659+/-0.058+/-0.0768+/-0.019+/-0.0151+/-0.700+/-0.088+/-0.0146+/-0.0354 0.0949 0.188 0.245 0.0565 0.0414 0.029 0.035 0.0844 0.0933 0.104 0.0526 0.0529 0.0316 0.0279 0.319 0.0565 0.0269 0.0316 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 07/26/06 1329 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:*A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-030F Project: YANKO1204 Sample ID: 167014002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-032F 167014003 SE 15-JUN-06 13-JUL-06 Client 16.9%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO Parameter Qualifier Result Ui Rad Gamma Spec Analysis Gamma, Solid-FSS 6AM & ALL FSS 226 Ingrowth ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 0.728 U 0.00675 0.533 0.872 U 0.039 0.255 0.398 U 0.0308 U 0.016 U 0.00765 0.932 0.932 U -0.00891 U 0.0131 12.5 0.872 U -0.0199 0.364+/-0.237+/-0.0418+/-0.481+/-0.178+/-0.0383+/-0.0677+/-0.0982+/-0.0754+/-0.0921+/-0.0716+/-0.135+/-0.143+/-0.0374+/-0.038+/- 1.45+/-0.178+/-0.0274+/-0.073 0.098 0.0384 0.213 0.0487 0.0361 0.0312 0.0252 0.0683 0.0791 0.0638 0.0371 0.0528 0.0318 0.0288 0.247 0.0487 0.0224 0.0254+/-0.237+/-0.0418+/-0.481+/-0.178+/-0.0383+/-0.0677+/-0.0982+/-0.0754+/-0.0921+/-0.0716+/-0.135+/-0.143+/-0.0374+/-0.038+/-1.45+/-0.178+/-0.0274+/-0.073 0.214 0.0794 0.461 0.105 0.0776 0.0667 0.0574 0.145 0.177 0.133 0.0778 0.111 0.0686 0.0615 0.563 0.105 0.0479 0.0549 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1540 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysisi T Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-032F 167014003 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-043F 167014004 SE 16-JUN-06 13-JUL-06 Client 17.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.739 +/-0.220 Americium-241 U 0.00573 +/-0.0406 Bismuth-212 0.578 +/-0.361 Bismuth-214 0.803 +/-0.127 Cesium-134 U 0.0395 +/-0.0368 Cesium-137 0.129 +/-0.0584 Cobalt-60 0.108 +/-0.0589 Europium-152 U 0.0108 +/-0.0758 Europium-154 U -0.0057 +/-0.109 Europium-155 U 0.0791 +/-0.0674 Lead-212 0.690 +/-0.0968 Lead-214 0.771 +/-0.113 Manganese-54 U 0.0123 +/-0.0311 Niobium-94 U 0.0307 +/-0.0305 Potassium-40 9.78 +/-0.991 Radium-226 0.803 +/-0.127 Silver-108m U 0.00833 +/-0.0256 Thallium-208 0.246 +/-0.0732 0.101 0.0371 0.231 0.0494 0.0341 0.027 0.0251 0.0661 0.0787 0.0622 0.0477 0.0439 0.0273 0.0282 0.263 0.0494 0.0236 0.0255+/-0.220+/-0.0406+/-0.361+/-0.127+/-0.0368+/-0.0584+/-0.0589+/-0.0758+/-0.109+/-0.0674+/-0.0968+/-0.113+/-0.0311+/-0.0305+/-0.991+/-0.127+/-0.0256+/-0.0732 0.217 0.0768 0.493 0.105 0.0727 0.0577 0.056 0.139 0.173 0.129 0.0986 0.0928 0.0588 0.0598 0.582 0.105 0.050 0.0545 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1541 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-043F Project: YANKO 1204 Sample ID: 167014004 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis 77- .... .i -- --Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-OIOF 167014005 SE 12-JUN-06 13-JUL-06 Client 11.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.496 Americium-241 U -0.0169 Bismuth-212 0.378 Bismuth-214 0.439 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 U 0.00981 0.363 0.238 U 0.0488 U -0.0121 U 0.0543 0.592 0.480 U-0.000796 U 0.00632 10.0 0.439 U 0.00188 0.210+/-0.150+/-0.0813+/-0.231+/-0.073+/-0.0248+/-0.0462+1-0.0501+/-0.0533 F/-0.0636+/-0.0514+/-0.0609+/-0.0819+/-0.020+/-0.018+/-0.838+/-0.073+/-0.017+/-0.0448 0.0569 0.0677 0.129 0.0314 0.0219 0.0163 0.0197 0.0479 0.0536 0.0489 0.0256 0.0308 0.0168 0.016 0.120 0.0314 0.0153 0.0149+1-0.150+/-0.0813+/-0.231+/-0.073+/-0.0248+/-0.0462+/-0.0501+/-0.0533+/-0.0636+1-0.0514+/-0.0609+/-0.0819+/-0.020+/-0.018+/-0.838+/-0.073+/-0.017+/-0.0448 0.125 0.141 0.280 0.0672 0.047 0.0353 0.0437 0.101 0.119 0.102 0.0536 0.0652 0.0367 0.0343 0.283 0.0672 0.0326 0.0323 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1653 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-OIOF Project: YANK01204 Sample ID: 167014005 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mid> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-016F 167014006 SE 12-JUN-06 13-JUL-06 Client 17.5%Project: Client ID: Vol. Recv.: YANKO 1204 YANKO0 I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.984 U 0.00326 0.530 0.633 U 0.0371 0.0689 0.105 U 0.000182 U -0.0117 U 0.0431 0.870 0.677 U 0.0291 U 0.00937 7.94 0.633 U -0.00455 0.266+/-0.170+/-0.0828+/-0.238+/-0.0761+/-0.0311+/-0.035+/-0.0368+/-0.0573+/-0.0611+/-0.0538+/-0.0607+/-0.0689+/-0.0227+/-0.0171+/-0.695+/-0.0761+/-0.0163+/-0.0464 0.0484 0.0715 0.124 0.0318 0.0209 0.0164 0.0153 0.0449 0.0515 0.0511 0.025 0.0309 0.017 0.0156 0.144 0.0318 0.014 0.0158+/-0.170+/-0.0828+/-0.238+/-0.0761+/-0.0311+/-0.035+/-0.0368+/-0.0573+/-0.0611+/-0.0538+/-0.0607+/-0.0689+/-0.0227+/-0.0171+/-0.695+/-0.0761+/-0.0163+/-0.0464 0.105 0.147 0.265 0.0672 0.0442 0.0348 0.0339 0.0938 0.112 0.105 0.0518 0.0648 0.0363 0.0331 0.319 0.0672 0.0295 0.0336 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1654 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-016F Project: YANK01204 Sample ID: 167014006 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-022F 167014007 SE 12-JUN-06 13-JUL-06 Client 12.3%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.561 U -0.0549 U 0.230 0.380 U 0.00668 0.115 U 0.0289 U -0.00511 U 0.0448 U 0.0137 0.503 0.426 U -0.00387 U 0.00643 9.79 0.380 U -0.00107 0.154+/-0.146+/-0.107+/-0.255+/-0.0762+/-0.0265+/-0.0429+/-0.0293+/-0.0486+/-0.0479+/-0.0502+/-0.0539+/-0.0715+/-0.0198+/-0.0163+/-0.799+/-0.0762+/-0.0159+/-0.0352 0.0575 0.090 0.109 0.0263 0.019 0.0142 0.0178 0.0409 0.0505 0.0474 0.0238 0.0313 0.0162 0.0144 0.125 0.0263 0.0141 0.0183+/-0.146+/-0.107+/-0.255+/-0.0762+/-0.0265+/-0.0429+/-0.0293+/-0.0486+/-0.0479+/-0.0502+/-0.0539+/-0.0715+/-0.0198+/-0.0163+/-0.799+/-0.0762+/-0.0159+/-0.0352 0.125 0.188 0.238 0.0567 0.041 0.0308 0.0396 0.0865 0.112 0.0985 0.0499 0.0659 0.0352 0.0309 0.290 0.0567 0.030 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1654 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-022F Project: YANKO1204 Sample ID: 167014007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-013F 167014008 SE 13-JUN-06 13-JUL-06 Client 15%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamima,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.676 Americium-241 U 0.0183 Bismuth-212 1.05 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.694 UI 0.00 0.219 0.136 U 0.000672 U -0.0409 U 0.0334 0.847 0.828 U -0.0234 U 0.00553 13.0 0.694 U 0.0131 0.246+/-0.161+/-0.0927+/-0.327+/-0.0959+/-0.0439+/-0.0474+/-0.0562+/-0.0606+/-0.0699+/-0.0567+/-0.069+/-0.115+/-0.0236+/-0.0191+/-0.930+/-0.0959+/-0.0203+/-0.0511 0.0834 0.0833 0.146 0.0344 0.0273 0.0222 0.0181 0.0526 0.0566 0.055 0.0286 0.0356 0.0183 0.017 0.139 0.0344 0.018 0.0209+/-0.161+/-0.0927+/-0.327+/-0.0959+/-0.0439+/-0.0474+/-0.0562+/-0.0606+/-0.0699+/-0.0567+/-0.069+/-0.115+/-0.0236+/-0.0191+/-0.930+/-0.0959+/-0.0203+/-0.0511 0.178 0.172 0.314 0.0734 0.0577 0.0471 0.0404 0.110 0.125 0.114 0.0596 0.0749 0.0397 0.0364 0.319 0.0734 0.038 0.0443 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1655 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-013F Project: YANK01204 Sample ID: 167014008 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--U ncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-024F 167014009 SE 07-JUN-06 13-JUL-06 Client 14.7%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result U Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.918 Americium-241 U 0.0447 Bismuth-212 0.768 Bismuth-214 0.761 Cesium-134 U 0.0414 Cesium-137 U 0.0241 Cobalt-60 U -0.00163 Europium-152 U -0.0585 Europium-154 U 0.0263 Europium-155 U -0.00341 Lead-212 0.949 Lead-214 0.922 Manganese-54 U 0.034 Niobium-94 U 0.0134 Potassium-40 11.5 Radium-226 0.761 Silver-108m U -0.00663 Thallium-208 0.290 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.208+/-0.111+/-0.285+/-0.104+/-0.0473+/-0.030+/-0.0261+/-0.0568+/-0.0754+/-0.0663+/-0.0761+/-0.0978+/-0.0258+/-0.0232+/-0.999+/-0.104+/-0.0198+/-0.0516 0.0834 0.0922 0.163 0.039 0.0278 0.0241 0.0218 0.047 0.0663 0.0585 0.031 0.0357 0.0198 0.0204 0.183 0.039 0.0168 0.0176+/-0.208+/-0.111+/-0.285+/-0.104+/-0.0473+/-0.030+/-0.0261+/-0.0568+/-0.0754+/-0.0663+/-0.0761+/-0.0978+/-0.0258+/-0.0232+/-0.999+/-0.104+/-0.0198+/-0.0516 0.179 0.190 0.350 0.0829 0.0592 0.051 0.0482 0.0996 0.145 0.121 0.0647 0.0754 0.043 0.0433 0.411 0.0829 0.0358 0.0379 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1655 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-024F 167014009 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-025F 167014010 SE 07-JUN-06 13-JUL-06 Client 18.6%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-24 I Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.999 U 0.049 0.585 0.545 U 0.0292 0.550 1.36 U -0.0234 U 0.0209 U 0.0892 0.849 0.781 U -0.00452 U 0.00252 10.5 0.545 U 0.00931 0.305+/-0.192+/-0.0951+/-0.288+/-0.0903+/-0.028+/-0.0705+/-0.101+/-0.0565+/-0.0572+/-0.0707+/-0.0729+/-0.0987+/-0.0255+/-0.0217+/-0.808+/-0.0903+/-0.0206+/-0.0557 0.0839 0.083 0.163 0.0386 0.0252 0.0214 0.0183 0.050 0.0504 0.0521 0.0302 0.0348 0.0222 0.0185 0.117 0.0386 0.0187 0.0191+/-0.192+/-0.0951+/-0.288+/-0.0903+/-0.028+/-0.0705+/-0.101+/-0.0565+/-0.0572+/-0.0707+/-0.0729+/-0.0987+/-0.0255+/-0.0217+/-0.808+/-0.0903+/-0.0206+/-0.0557 0.177 0.171 0.343 0.0809 0.053 0.0451 0.040 0.104 0.110 0.107 0.0623 0.0727 0.047 0.0389 0.267 0.0809 0.039 0.0403 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1656 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-025F Project: YANK01204 Sample ID: 167014010 ClientID:

YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: 9106-0014-031F Project: YANKO 1204 Sample ID: 167014011 ClientID:

YANK001 Matrix: SE Vol. Recv.: Collect Date: 07-JUN-06 Receive Date: 13-JUL-06 Collector:

Client Moisture:

10.3%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.178 Americium-241 U -0.00504 +/-0.113 Bismuth-212 0.741 +/-0.250 Bismuth-214 0.812 +/-0.116 Cesium-134 U 0.0372 +/-0.0376 Cesium-137 U 0.0385 +/-0.0206 Cobalt-60 U 0.039 +/-0.0225 Europium-152 U -0.0485 +/-0.0459 Europium-154 U 0.0155 +1-0.0555 Europium-155 U 0.0539 +/-0.073 Lead-212 0.977 +/-0.101 Lead-214 0.807 +/-0.115 Manganese-54 U 0.0335 +/-0.0219 Niobium-94 U 0.00189 +/-0.017 Potassium-40 10.5 +1-1.05 Radium-226 0.812 +/-0.116 Silver-108m U -0.00178 +/-0.0158 Thallium-208 0.291 +/-0.0494 0.0482 0.0943 0.115 0.0291 0.0234 0.0192 0.0205 0.0384 0.0477 0.0463 0.0237 0.0308 0.0168 0.0143 0.138 0.0291 0.0137 0.0173+/-0.178+/-0.113+1-0.250+/-0.116+/-0.0376+/-0.0206+/-0.0225+/-0.0459+/-0.0555+/-0.073+/-0.101+/-0.115+/-0.0219+/-0.017+1-1.05+/-0.116+/-0.0158+/-0.0494 0.104 0.194 0.245 0.0613 0.049 0.0403 0.0439 0.0805 0.103 0.0955 0.049 0.0641 0.0358 0.0303 0.305 0.0613 0.0287 0.0364 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1656 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-031F Proiect: YANK01204 Sample ID: 167014011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-017F 167014012 SE 09-JUN-06 13-JUL-06 Client 23.9%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.585 +/-0.157 Americium-241 U 0.00715 +/-0.140 Bismuth-212 0.540 +/-0.248 Bismuth-214 0.519 +/-0.0827 Cesium-134 U 0.0431 +/-0.0345 Cesium-137 0.552 +/-0.0613 Cobalt-60 0.593 +/-0.0679 Europium-152 U 0.0199 +/-0.0623 Europium-154 U 0.0297 +/-0.0712 Europium-155 U 0.0211 +/-0.0634 Lead-212 0.630 +/-0.0596 Lead-214 0.635 +/-0.0955 Manganese-54 U 0.0267 +/-0.0283 Niobium-94 U 0.00601 +/-0.0198 Potassium-4 0 10.8 +/-0.853 Radium-226 0.519 +/-0.0827 Silver-108m U 0.00616 +/-0.0211 Thallium-208 0.187 +/-0.0443 0.0783 0.0844 0.155 0.035 0.0257 0.0203 0.0207 0.0545 0.0618 0.0586 0.0312 0.036 0.0216 0.0176 0.165 0.035 0.0182 0.0221+/-0.157+/-0.140+/-0.248+/-0.0827+/-0.0345+/-0.0613+/-0.0679+/-0.0623+/-0.0712+/-0.0634+/-0.0596+/-0.0955+/-0.0283+/-0.0198+/-0.853+/-0.0827+/-0.0211+/-0.0443 0.166 0.174 0.330 0.074 0.0543 0.0429 0.0452 0.114 0.134 0.121 0.0646 0.0752 0.0459 0.0372 0.368 0.074 0.0382 0.0465 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1656 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-017F 167014012 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-023F 167014013 SE 09-JUN-06 13-JUL-06 Client 16.7%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Rad Gamma Spec Analysis:ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.504 +/-0.136 Americium-241 U 0.0147 +/-0.0256 Bismuth-212 U 0.286 +/-0.244 Bismuth-214 0.309 +/-0.0779 Cesium-134 U 0.0304 +/-0.0307 Cesium-137 U 0.0453 +/-0.0357 Cobalt-60 U 0.049 +/-0.0418 Europium-152 U -0.0248 +/-0.0536 Europium-154 U -0.0328 +/-0.0808 Europium-155 U -0.00621 +/-0.0446 Lead-212 0.430 +/-0.0563 Lead-214 0.392 +/-0.0859 Manganese-54 U 0.00386 +/-0.0256 Niobium-94 U -0.0144 +/-0.0191 Potassium-40 9.97 +/-1.00 Radium-226 0.309 +/-0.0779 Silver-108m U -0.0152 +/-0.018 Thallium-208 0.144 +/-0.0481 0.0594 0.0237 0.145 0.0363 0.0256 0.0236 0.0323 0.0438 0.0637 0.0379 0.0272 0.0318 0.0217 0.0146 0.138 0.0363 0.0149 0.0186+/-0.136+/-0.0256+/-0.244+/-0.0779+/-0.0307+/-0.0357+/-0.0418+/-0.0536+/-0.0808+/-0.0446+/-0.0563+/-0.0859+/-0.0256+/-0.0191+/- 1.00+/-0.0779+/-0.018+/-0.0481 0.134 0.0496 0.319 0.0786 0.0556 0.0507 0.0704 0.0941 0.143 0.0798 0.0575 0.0684 0.0476 0.0325 0.333 0.0786 0.0323 0.0407 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1657 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-023F Proiect: YANK01204 Sample ID: 167014013 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-035F 167014014 SE 09-JUN-06 13-JUL-06 Client 15.6%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.280 Americium-241 U -0.0316 +/-0.0452 Bismuth-212 0.596 +/-0.343 Bismuth-214 0.788 +/-0.141 Cesium-134 U 0.0522 +/-0.0737 Cesium-137 0.200 +/-0.0817 Cobalt-60 0.249 +/-0.0969 Europium-152 U 0.0229 +/-0.100 Europium-154 U 0.0251 +/-0.117 Europium-155 U -0.00216 +/-0.070 Lead-212 0.972 +/-0.0939 Lead-214 0.799 +/-0.115 Manganese-54 U 0.00477 +/-0.0378 Niobium-94 U -0.00707 +/-0.031 Potassium-40 11.9 +/-1.26 Radium-226 0.788 +/-0.141 Silver-108m U -0.0199 +/-0.0273 Thallium-208 0.288 +/-0.0761 0.219 0.0412 0.251 0.0559 0.037 0.0277 0.0373 0.0607 0.102 0.0635 0.0353 0.0471 0.0321 0.0257 0.282 0.0559 0.0227 0.0295+/-0.280+/-0.0452+/-0.343+/-0.141+/-0.0737+/-0.0817+/-0.0969+/-0.100+/-0.117+/-0.070+/-0.0939+/-0.115+/-0.0378+/-0.031+/-1.26+/-0.141+/-0.0273+/-0.0761 0.457 0.0853 0.541 0.120 0.0798 0.0601 0.0822 0.130 0.224 0.132 0.0744 0.100 0.0697 0.0558 0.640 0.120 0.0489 0.0635 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1657 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis T I Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-035F 167014014 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.72 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-039F 167014015 SE 09-JUN-06 13-JUL-06 Client 17.4%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.793 Americium-241 U 0.154 Bismuth-212 0.561 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.586 UI 0.00 0.377 1.36 U -0.00945 U 0.0452 U 0.0452 0.823 0.741 U -0.0148 U 0.0036 11.2 0.586 U -0.0016 0.264+/-0.160+/-0.148+/-0.210+/-0.0798+/-0.0344+/-0.0341+/-0.0739+/-0.0459+/-0.0556+/-0.0509+/-0.0553+/-0.0694+/-0.0195+/-0.0166+/-0.630+/-0.0798+/-0.0148+/-0.0331 0.0575 0.0807 0.120 0.0277 0.0196 0.0141 0.014 0.0408 0.048 0.048 0.0266 0.0272 0.0162 0.014 0.117 0.0277 0.0129 0.0153+/-0.160+/-0.148+/-0.210+/-0.0798+/-0.0344+/-0.0341+/-0.0739+/-0.0459+/-0.0556+/-0.0509+/-0.0553+/-0.0694+/-0.0195+/-0.0166+/-0.630+/-0.0798+/-0.0148+/-0.0331 0.120 0.166 0.250 0.0577 0.0407 0.0296 0.030 0.0845 0.101 0.0987 0.0547 0.0564 0.0339 0.0292 0.254 0.0577 0.0268 0.0318 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1657 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 73 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-039F Project: YANK01204 Sample ID: 167014015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.74 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certificateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-042F 167014016 SE 09-JUN-06 13-JUL-06 Client 11.6%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.743 +/-0.169 Americium-241 U 0.0431 +/-0.0625 Bismuth-212 0.666 +/-0.275 Bismuth-214 0.754 +/-0.0975 Cesium- 134 U 0.0234 +/-0.0216 Cesium-137 0.152 +/-0.0495 Cobalt-60 0.666 +/-0.0667 Europium-152 U 0.00416 +/-0.0435 Europium-154 U 0.0541 +/-0.043 Europium-155 U 0.039 +/-0.0761 Lead-212 0.800 +/-0.082 Lead-214 0.843 +/-0.110 Manganese-54 U 0.00321 +/-0.0174 Niobium-94 U 0.0199 +/-0.0157 Potassium-40 11.9 +/-0.986 Radium-226 0.754 +/-0.0975 Silver-108m U 0.00896 +/-0.0146 Thallium-208 0.242 +/-0.0462 0.0565 0.0592 0.105 0.0253 0.014 0.0135 0.0144 0.0388 0.0442 0.046 0.0261 0.0267 0.0153 0.0146 0.116 0.0253 0.0132 0.0138+/-0.169+/-0.0625+/-0.275+/-0.0975+/-0.0216+/-0.0495+/-0.0667+/-0.0435+/-0.043+/-0.0761+/-0.082+/-0.110+/-0.0174+/-0.0157+/-0.986+/-0.0975+/-0.0146+/-0.0462 0.119 0.122 0.221 0.0532 0.0297 0.0285 0.031 0.0806 0.0942 0.0945 0.0537 0.0556 0.0322 0.0305 0.252 0.0532 0.0275 0.0291 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/26/06 1657 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 75 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-042F Project: YANK01204 Sample ID: 167014016 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.76 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-034F 167014017 SE 09-JUN-06 13-JUL-06 Client 9.11%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.774 +/-0.177 Americium-241 U 0.0557 +/-0.115 Bismuth-212 0.701 +/-0.390 Bismuth-214 0.708 +/-0.0966 Cesium-134 UI 0.00 +/-0.0363 Cesium-137 0.300 +/-0.0445 Cobalt-60 1.01 +/-0.088 Europium-152 U -0.0203 +/-0.0571 Europium-154 U 0.0591 +/-0.0739 Europium-155 U 0.0339 +/-0.0558 Lead-212 0.799 +/-0.0626 Lead-214 0.656 +/-0.0897 Manganese-54 U 0.0225 +/-0.0259 Niobium-94 U -0.00317 +/-0.0209 Potassium-40 12.8 +/-0.888 Radium-226 0.708 +/-0.0966 Silver-108m U -0.00408 +/-0.0185 Thallium-208 0.215 +/-0.0467 0.0806 0.0919 0.144 0.0324 0.0205 0.0201 0.0186 0.0466 0.0666 0.0516 0.0258 0.0356 0.0211 0.0175 0.150 0.0324 0.0161 0.0193+/-0.177+/-0.115+/-0.390+/-0.0966+/-0.0363+/-0.0445+/-0.088+/-0.0571+/-0.0739+/-0.0558+/-0.0626+/-0.0897+/-0.0259+/-0.0209+/-0.888+/-0.0966+/-0.0185+/-0.0467 0.170 0.189 0.306 0.0686 0.0437 0.0424 0.0408 0.0975 0.143 0.107 0.0537 0.0743 0.0447 0.0369 0.335 0.0686 0.0337 0.0408 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH-l 1 07/26/06 1749 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 77 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-034F Project: YANK01204 Sample ID: 167014017 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.78 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certi cateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-029F 167014018 SE 09-JUN-06 13-JUL-06 Client 22.1%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americiurn-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.460 U 0.00292 U 0.231 0.285 U 0.0258 0.058 0.0938 U -0.00717 U 0.00113 U 0.0232 0.415 0.399 U 0.00845 U -0.00495 8.63 0.285 U 0.0057 0.187+/-0.188+/-0.0299+/-0.266+/-0.0933+/-0.0277+/-0.0403+/-0.0584+/-0.0577+/-0.0818+1-0.0531+/-0.0802+/-0.103+/-0.0226+/-0.024+/- 1.03+/-0.0933+/-0.0209+/-0.0453 0.069 0.0283 0.170 0.0442 0.0267 0.0266 0.0219 0.0451 0.0691 0.0496 0.0324 0.0361 0.0208 0.0198 0.179 0.0442 0.0189 0.0185+/-0.188+/-0.0299+/-0.266+/-0.0933+/-0.0277+/-0.0403+/-0.0584+/-0.0577+/-0.0818+/-0.0531+/-0.0802+/-0.103+/-0.0226+/-0.024+/-1.03+/-0.0933+/-0.0209+/-0.0453 0.154 0.0589 0.372 0.095 0.0581 0.057 0.0498 0.0972 0.155 0.104 0.068 0.0773 0.046 0.043 0.418 0.095 0.0405 0.0406 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1749 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 79 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-029F 167014018 Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.80 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-009F 167014019 SE 13-JUN-06 13-JUL-06 Client 18.6%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.523 U 0.0495 0.389 0.425 U 0.0273 0.164 0.0599 U 0.029 U 0.0147 U -0.00191 0.575 0.462 U 0.00293 U 0.0131 9.93 0.425 U 0.013 0.154+/-0.187+/-0.108+/-0.227+/-0.100+/-0.0249+/-0.0358+/-0.043+/-0.0506+/-0.0636+1-0.0531+/-0.0609+/-0.0816+/-0.0234+/-0.0181+/-0.871+/-0.100+/-0.0182+/-0.0411 0.0585 0.0744 0.152 0.0317 0.0232 0.0185 0.0149 0.046 0.0555 0.0476 0.0258 0.0339 0.0201 0.0166 0.133 0.0317 0.0164 0.0163+/-0.187+/-0.108+/-0.227+/-0.100+/-0.0249+/-0.0358+/-0.043+/-0.0506+/-0.0636+/-0.0531+/-0.0609+/-0.0816+/-0.0234+/-0.0181+/-0.871+/-0.100+/-0.0182+/-0.0411 0.127 0.154 0.325 0.0677 0.0495 0.0396 0.0339 0.0967 0.122 0.0986 0.0538 0.0712 0.043 0.0353 0.306 0.0677 0.0347 0.0349 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI1 07/26/06 1749 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 81 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-009F Project: YANK01204 Sample ID: 167014019 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.82 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-028F 167014020 SE 13-JUN-06 13-JUL-06 Client 18.9%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.301 +/-0.211 Americium-241 U -0.00629 +/-0.0376 Bismuth-212 U 0.225 +/-0.411 Bismuth-214 0.348 +/-0.101 Cesium-134 U -0.00601 +/-0.0335 Cesium-137 0.0872 +/-0.0487 Cobalt-60 0.186 +/-0.0604 Europium-152 U -0.00687 +/-0.0692 Europium-154 U 0.0397 +/-0.092 Europium-155 U 0.028 +/-0.0814 Lead-212 0.348 +/-0.0712 Lead-214 0.354 +/-0.109 Manganese-54 U -0.00397 +/-0.0328 Niobium-94 U 0.0142 +/-0.0271 Potassium-40 8.46 +/-1.06 Radium-226 0.348 +/-0.101 Silver-108m U-0.000772

+/-0.0238 Thallium-208 0.148 +/-0.0603 0.0986 0.0337 0.191 0.0472 0.0277 0.0273 0.0284 0.059 0.0819 0.0536 0.0406 0.0443 0.0272 0.0243 0.250 0.0472 0.0215 0.0261+/-0.211+/-0.0376+/-0.411+/-0.101+/-0.0335+/-0.0487+/-0.0604+/-0.0692+/-0.092+/-0.0814+/-0.0712+/-0.109+/-0.0328+/-0.0271+/-1.06+/-0.101+/-0.0238+/-0.0603 0.213 0.070 0.413 0.101 0.0601 0.0584 0.0627 0.125 0.180 0.112 0.0845 0.0938 0.0589 0.052 0.558 0.101 0.0457 0.0558 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/26/06 1750 548621 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1616 547812 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 83 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-028F Project: YANKO 1204 Sample ID: 167014020 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.84 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: 9106-0014-028FS Project: YANKO 1204 Sample ID: 167014021 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 13-JUN-06 Receive Date: 13-JUL-06 Collector:

Client Moisture:

16.1%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 UI 0.00 +/-0.200 Americium-241 U -0.00413 +/-0.0314 Bismuth-212 U 0.332 +/-0.329 Bismuth-214 0.372 +/-0.0942 Cesium-134 U 0.0389 +/-0.0289 Cesium-137 0.120 +/-0.0639 Cobalt-60 0.199 +/-0.0569 Europium-152 U -0.0287 +/-0.0614 Europium-154 U 0.0592 +/-0.0853 Europium-155 U -0.00257 +1-0.0552 Lead-212 0.445 +/-0.0792 Lead-214 0.412 +/-0.122 Manganese-54 U -0.0239 +/-0.0293 Niobium-94 U 0.0106 +/-0.0242 Potassium-40 10.4 +1-1.15 Radium-226 0.372 +/-0.0942 Silver-108m U -0.0133 +/-0.0221 Thallium-208 0.167 +/-0.056 0.144 0.029 0.186 0.041 0.0287 0.0189 0.0241 0.0529 0.0786 0.0497 0.0338 0.0376 0.0233 0.0213 0.150 0.041 0.0184 0.0221+/-0.200+/-0.0314+/-0.329+/-0.0942+/-0.0289+/-0.0639+/-0.0569+/-0.0614+/-0.0853+/-0.0552+/-0.0792+/-0.122+/-0.0293+/-0.0242+/-1.15+/-0.0942+/-0.0221+/-0.056 0.305 0.0604 0.405 0.0888 0.0623 0.0418 0.0547 0.113 0.174 0.104 0.071 0.0806 0.0513 0.0463 0.364 0.0888 0.0396 0.0479 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 07/27/06 1107 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 85 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-028FS Project: YANK01204 Sample ID: 167014021 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.86 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-036F 167014022 SE 13-JUN-06 13-JUL-06 Client 10.7%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.643 U 0.00113 0.456 0.559 U 0.0429 0.0785 0.341 U -0.0104 U -0.0196 U 0.0373 0.681 0.529 U -0.0127 U 0.0195 10.4 0.559 U-0.000945 0.203+/-0.175+/-0.0908+/-0.245+/-0.0753+/-0.0342+/-0.0397+/-0.0576+/-0.0522+/-0.0679+/-0.0522+/-0.0605+/-0.0819+/-0.0233+/-0.0285+/-0.834+/-0.0753+/-0.0206+/-0.045 0.0685 0.0775 0.152 0.032 0.0235 0.0199 0.0156 0.0458 0.0562 0.0491 0.0268 0.0326 0.019 0.0167 0.150 0.032 0.0155 0.0174+/-0.175+/-0.0908+/-0.245+/-0.0753+/-0.0342+/-0.0397+/-0.0576+/-0.0522+/-0.0679+/-0.0522+/-0.0605+/-0.0819+/-0.0233+/-0.0285+/-0.834+/-0.0753+/-0.0206+/-0.045 0.147 0.160 0.323 0.0679 0.0497 0.0421 0.035 0.096 0.122 0.102 0.0557 0.0684 0.0407 0.0355 0.338 0.0679 0.0327 0.037 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1107 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 87 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-036F 167014022 Project: YANK01204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.88 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Project: YANKO1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-040F 167014023 SE 13-JUN-06 13-JUL-06 Client 11.2%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.604 Americium-241 U -0.035 Bismuth-212 0.505 Bismuth-214 0.550 -Cesium-134 U 0.0374 -Cesium-137 0.0962 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.436 U -0.024 U -0.0143 U 0.060 0.726 0.704 U 0.00967 U -0.00368 12.3 0.550 U 0.0134 0.253 H+/-0.184+/-0.0935+/-0.378+/-0.091 I F/-0.0379+/-0.0474 F/-0.0703 F/-0.0625 k/-0.0697 F/-0.0642+/-0.070+/-0.0988+/-0.0278+/-0.0242+/-0.978+/-0.0911 1/-0.0191-/-0.0504 0.079 0.0829 0.155 0.0359 0.0266 0.0206 0.0233 0.0469 0.0572 0.0587 0.0288 0.0372 0.0238 0.020 0.120 0.0359 0.0174 0.021+/-0.184+/-0.0935+/-0.378+/-0.0911+/-0.0379+/-0.0474+/-0.0703+/-0.0625+/-0.0697+/-0.0642+/-0.070+/-0.0988+/-0.0278+/-0.0242+/-0.978+/-0.0911+/-0.0191+/-0.0504 0.170 0.172 0.335 0.0768 0.0567 0.0441 0.0513 0.0995 0.127 0.122 0.0604 0.0786 0.0509 0.0427 0.287 0.0768 0.037 0.0448 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1108 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 89 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-040F Proiect: YANKO 1204 Sample ID: 167014023 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.90 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-041F 167014024 SE 13-JUN-06 13-JUL-06 Client 10.8%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.547 +/-0.145 Americium-241 U 0.00498 +/-0.0752 Bismuth-212 0.389 +/-0.215 Bismuth-214 0.448 +/-0.0755 Cesium-134 U 0.0105 +/-0.0227 Cesium-137 0.0476 +/-0.0273 Cobalt-60 0.147 +/-0.042 Europium-152 U 0.0482 +/-0.0459 Europium-154 U -0.0216 +/-0.0601 Europium-155 U 0.0447 +/-0.0499 Lead-212 0.630 +/-0.0607 Lead-214 0.567 +/-0.0822 Manganese-54 U 0.0092 +/-0.0184 Niobium-94 U 0.00965 +/-0.0163 Potassium-40 9.76 +/-0.776 Radium-226 0.448 +/-0.0755 Silver-108m U 0.0126 +/-0.0123 Thallium-208 0.200 +/-0.0496 0.0518 0.0715 0.118 0.0277 0.0198 0.0155 0.0169 0.0439 0.0488 0.0475 0.0259 0.0299 0.0169 0.0146 0.128 0.0277 0.0146 0.0171+1-0.145+/-0.0752+/-0.215+/-0.0755+/-0.0227+/-0.0273+/-0.042+/-0.0459+/-0.0601+/-0.0499+/-0.0607+/-0.0822+/-0.0184+/-0.0163+/-0.776+/-0.0755+/-0.0123+/-0.0496 0.112 0.148 0.253 0.0591 0.0422 0.0332 0.0372 0.0919 0.107 0.0982 0.0537 0.0627 0.0362 0.0311 0.289 0.0591 0.0308 0.0362 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1108 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 91 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-04IF 167014024 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.92 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-041FS 167014025 SE 13-JUN-06 13-JUL-06 Client 10.2%Project: Client ID: Vol. Recv.: YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.539 U 0.0699 0.589 0.481 U 0.0246 0.0724 0.104 U -0.0153 U 0.00106 U 0.0478 0.586 0.539 U -0.00558 U -0.0158 9.30 0.481 U 0.00497 0.196+/-0.160+/-0.0965+/-0.253+/-0.0848+/-0.0182+/-0.0243+/-0.0419+/-0.0405+/-0.0554+/-0.047+/-0.0693+/-0.0856+/-0.0176+/-0.0148+/-0.911+/-0.0848+/-0.0144+/-0.0423 0.0482 0.0885 0.117 0.0229 0.0178 0.0118 0.0136 0.0364 0.0469 0.0461 0.0222 0.0263 0.0152 0.0113 0.110 0.0229 0.0132 0.0136+/-0.160+/-0.0965+/-0.253+/-0.0848+/-0.0182+/-0.0243+/-0.0419+/-0.0405+/-0.0554+/-0.047+/-0.0693+/-0.0856+/-0.0176+/-0.0148+/-0.911+/-0.0848+/-0.0144+/-0.0423 0.105 0.183 0.250 0.0491 0.0381 0.0255 0.0303 0.0766 0.102 0.0954 0.0462 0.0554 0.0327 0.0244 0.252 0.0491 0.0279 0.029 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI-1 07/27/06 1109 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 93 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-041FS Proiect: YANK01204 Sample ID: 167014025 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.94 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-012F 167014026 SE 06-JUN-06 13-JUL-06 Client 21%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.783 +/-0.225 Americium-241 0.172 +/-0.130 Bismuth-212 0.827 +/-0.235 Bismuth-214 0.708 +/-0.100 Cesium-134 UI 0.00 +/-0.0528 Cesium-137 1.15 +/-0.0757 Cobalt-60 1.45 +/-0.0992 Europium-152 U -0.0298 +/-0.0726 Europium-154 U 0.0875 +/-0.0739 Europium-155 U 0.053 +/-0.0711 Lead-212 1.10 +/-0.0737 Lead-214 0.921 +/-0.0946 Manganese-54 U -0.00718 +/-0.0308 Niobium-94 U 0.0139 +/-0.0244 Potassium-40 14.5 +/-0.915 Radium-226 0.708 +/-0.100 Silver-108m U 0.0151 +/-0.0259 Thallium-208 0.378 +/-0.061 0.0914 0.0818 0.175 0.0408 0.031 0.0226 0.0213 0.0578 0.066 0.0605 0.0347 0.0433 0.0252 0.0209 0.176 0.0408 0.0214 0.0218+/-0.225+/-0.130+/-0.235+/-0. 100+/-0.0528+/-0.0757+/-0.0992+/-0.0726+/-0.0739+/-0.0711+/-0.0737+/-0.0946+/-0.0308+/-0.0244+/-0.915+/-0.100+/-0.0259+/-0.061 0.191 0.167 0.367 0.0848 0.0644 0.047 0.0456 0.119 0.140 0.124 0.071 0.0892 0.0526 0.0435 0.383 0.0848 0.0441 0.0453 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1109 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 95 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-012F Proiect: YANK01204 Sample ID: 167014026 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.96 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-019F 167014027 SE 06-JUN-06 13-JUL-06 Client 23.1%Project: YANK01204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.936 +/-0.331 Americium-241 U 0.0563 +/-0.0548 Bismuth-212 1.05 +/-0.558 Bismuth-214 0.699 +/-0.143 Cesium-134 U 0.00805 +/-0.0506 Cesium-137 0.749 +1-0.115 Cobalt-60 1.32 +/-0.128 Europium-152 U -0.0232 +/-0.106 Europium-154 U -0.0858 +/-0.118 Europium-155 U 0.0518 +/-0.0886 Lead-212 0.958 +/-0.108 Lead-214 0.709 +/-0.137 Manganese-54 U 0.0226 +/-0.0488 Niobium-94 U 0.0185 +/-0.0394 Potassium-40 12.0 +/-1.25 Radium-226 0.699 +/-0.143 Silver-108m U 0.00734 +/-0.0339 Thallium-208 0.302 +/-0.0952 0.138 0.0479 0.279 0.0654 0.0429 0.0368 0.0243 0.0823 0.0903 0.071 0.0419 0.0573 0.0423 0.0346 0.273 0.0654 0.0302 0.0329+/-0.331+/-0.0548+/-0.558+/-0.143+/-0.0506+/-0.115+/-0.128+/-0.106+/-0.118+/-0.0886+/-0.108+/-0.137+/-0.0488+/-0.0394+/-1.25+/-0.143+/-0.0339+/-0.0952 0.298 0.0988 0.599 0.139 0.0921 0.0786 0.0566 0.174 0.202 0.147 0.0878 0.121 0.0905 0.0737 0.627 0.139 0.064 0.0705 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1110 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 97 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-019F Proiect: YANK01204 Sample ID: 167014027 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.98 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-00IF 167014028 SE 09-JUN-06 13-JUL-06 Client 13.3%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.818 +/-0.213 Americium-241 U 0.00555 +/-0.0278 Bismuth-212 0.442 +/-0.336 Bismuth-214 0.682 +/-0.0928 Cesium- 134 UI 0.00 +/-0.0389 Cesium-137 U 0.00141 +/-0.0259 Cobalt-60 U 0.00894 +/-0.0256 Europium-152 U 0.0152 +/-0.0538 Europium-154 U -0.00542 +/-0.0717 Europium-155 U 0.0223 +/-0.048 Lead-212 0.830 +/-0.067 Lead-214 0.664 +/-0.104 Manganese-54 U 0.0107 +/-0.0263 Niobium-94 U -0.00348 +/-0.0221 Potassium-40 9.80 +/-0.916 Radium-226 0.682 +/-0.0928 Silver-108m U-0.000763

+/-0.0184 Thallium-208 0.246 +/-0.0568 0.0713 0.0259 0.142 0.0331 0.0309 0.0225 0.0226 0.0477 0.0599 0.0433 0.0285 0.0352 0.0231 0.0187 0.200 0.0331 0.0166 0.0193+/-0.213+/-0.0278+/-0.336+/-0.0928+/-0.0389+/-0.0259+/-0.0256+/-0.0538+/-0.0717+/-0.048+/-0.067+/-0.104+/-0.0263+/-0.0221+/-0.916+/-0.0928+/-0.0184+/-0.0568 0.156 0.0537 0.311 0.0718 0.0658 0.0482 0.0505 0.101 0.134 0.0902 0.0598 0.0748 0.050 0.0404 0.453 0.0718 0.0356 0.0418 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1111 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 99 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-OOIF Project: YANK01204 Sample ID: 167014028 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.100 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-002F 167014029 SE 09-JUN-06 13-JUL-06 Client 13.8%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Rad Gamma Spec Analysis)ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.683 +/-0.130 Americium-241 U 0.0398 +/-0.0989 Bismuth-212 0.500 +/-0.208 Bismuth-214 0.599 +/-0.061 Cesium-134 U 0.0338 +/-0.0265 Cesium-137 U 0.00361 +/-0.0156 Cobalt-60 U 0.00252 +/-0.014 Europium-152 U -0.00452 +/-0.0374 Europium-154 U -0.0116 +/-0.0529 Europium-155 U 0.0289 +/-0.0464 Lead-212 0.819 +/-0.0506 Lead-214 0.680 +/-0.063 Manganese-54 U 0.0227 +/-0.0332 Niobium-94 U 0.00682 +/-0.0152 Potassium-40 10.2 +/-0.614 Radium-226 0.599 +/-0.061 Silver-108m U -0.00997 +/-0.0117 Thallium-208 0.236 +/-0.0342 0.0383 0.0755 0.0909 0.0229 0.0167 0.0137 0.012 0.0347 0.0373 0.0461 0.0214 0.0235 0.0135 0.0121 0.104 0.0229 0.0101 0.0119+/-0.130+/-0.0989+/-0.208+/-0.061+/-0.0265+/-0.0156+/-0.014+/-0.0374+/-0.0529+/-0.0464+/-0.0506+/-0.063+/-0.0332+/-0.0152+/-0.614+/-0.061+/-0.0117+/-0.0342 0.082 0.156 0.193 0.0482 0.0351 0.0288 0.026 0.0723 0.0801 0.0951 0.0442 0.0492 0.0285 0.0253 0.227 0.0482 0.0213 0.0251 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1112 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 101 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-002F Project: YANKO 1204 Sample ID: 167014029 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.102 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-002FS 167014030 SE 09-JUN-06 13-JUL-06 Client 14.2%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.762 +/-0.147 Americium-241 U 0.051 +/-0.078 Bismuth-212 0.484 +/-0.212 Bismuth-214 0.578 +/-0.0911 Cesium- 134 U 0.0231 +/-0.0268 Cesium-137 U -0.0051 +/-0.0185 Cobalt-60 U -0.0161 +/-0.0216 Europium-152 U -0.00129 +/-0.0474 Europium-154 U -0.0126 +/-0.0564 Europium-155 U 0.0492 +/-0.0504 Lead-212 0.734 +/-0.0611 Lead-214 0.709 +/-0.0807 Manganese-54 U 0.00696 +/-0.0257 Niobium-94 U 0.0106 +/-0.0172 Potassium-40 8.47 +/-0.853 Radium-226 0.578 +/-0.0911 Silver-108m U -0.00797 +/-0.015 Thallium-208 0.246 +/-0.0426 0.0571 0.0694 0.120 0.0297 0.0203 0.0157 0.0135 0.0404 0.0475 0.0485 0.0249 0.0284 0.0161 0.0157 0.120 0.0297 0.013 0.0175+/-0.147+/-0.078+/-0.212+/-0.0911+/-0.0268+/-0.0185+/-0.0216+/-0.0474+/-0.0564+/-0.0504+/-0.0611+/-0.0807+/-0.0257+/-0.0172+/-0.853+/-0.0911+/-0.015+/-0.0426 0.124 0.144 0.260 0.0636 0.0435 0.0338 0.031 0.0855 0.106 0.101 0.0519 0.0602 0.0351 0.0336 0.280 0.0636 0.0278 0.0374 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1313 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 103 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-002FS Project: YANKO1204 Sample ID: 167014030 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.104 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: 9106-0014-005F Project: YANKO1204 Sample ID: 167014031 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 09-JUN-06 Receive Date: 13-JUL-06 Collector:

Client Moisture:

16.6%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.666 +/-0.141 Americium-241 U -0.0293 +/-0.0808 Bismuth-212 0.336 +/-0.241 Bismuth-214 0.515 +/-0.080 Cesium-134 Ul 0.00 +/-0.032 Cesium-137 0.0545 +/-0.0222 Cobalt-60 U 0.0288 +/-0.0201 Europium-152 U -0.0207 +/-0.0422 Europium-154 U 0.0212 +/-0.0517 Europium-155 U 0.0381 +/-0.0448 Lead-212 0.667 +/-0.0528 Lead-214 0.559 +/-0.0677 Manganese-54 UI 0.00 +/-0.028 Niobium-94 U 0.00513 +/-0.0156 Potassium-40 8.95 +/-0.705 Radium-226 0.515 +/-0.080 Silver-108m U 0.0023 +/-0.0131 Thallium-208 0.190 +/-0.0405 0.044 0.0732 0.108 0.0241 0.0196 0.0155 0.0199 0.0357 0.0466 0.0453 0.0234 0.0247 0.013 0.014 0.117 0.0241 0.0122 0.0137+/-0.141+/-0.0808+/-0.241+/-0.080+/-0.032+/-0.0222+/-0.0201+/-0.0422+/-0.0517+/-0.0448+/-0.0528+/-0.0677+/-0.028+/-0.0156+/-0.705+/-0.080+/-0.0131+/-0.0405 0.0966 0.152 0.233 0.0518 0.0418 0.033 0.0432 0.0756 0.102 0.0938 0.0488 0.0524 0.0284 0.0299 0.268 0.0518 0.026 0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 07/27/06 1313 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-005F Project: YANK01204 Sample ID: 167014031 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.106 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com CirtifirntP nf Annliqv Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-006F 167014032 SE 09-JUN-06 13-JUL-06 Client 16.8%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.771 +/-0.161 Americium-241 U 0.0412 +/-0.114 Bismuth-212 0.503 +/-0.229 Bismuth-214 0.569 +/-0.0761 Cesium-134 UI 0.00 +/-0.0508 Cesium-137 0.242 +1-0.0515 Cobalt-60 0.267 +/-0.0671 Europium-152 U -0.00441 +/-0.0541 Europium-154 U -0.0527 +/-0.0635 Europium-155 U 0.0474 +/-0.0592 Lead-212 0.669 +/-0.0628 Lead-214 0.514 +/-0.087 Manganese-54 U 0.0107 +/-0.0241 Niobium-94 U -0.00789 +/-0.0212 Potassium-40 9.61 +/-0.893 Radium-226 0.569 +/-0.0761 Silver-108m U -0.0119 +/-0.0202 Thallium-208 0.213 +/-0.0419 0.0711 0.077 0.143 0.0347 0.0184 0.0186 0.0166 0.0469 0.0486 0.0542 0.027 0.0329 0.0212 0.0178 0.164 0.0347 0.0166 0.0173+/-0.161+/-0.114+/-0.229+/-0.0761+/-0.0508+1-0.0515+/-0.0671+/-0.0541+/-0.0635+/-0.0592+/-0.0628+/-0.087+/-0.0241+/-0.0212+/-0.893+/-0.0761+/-0.0202+/-0.0419 0.152 0.159 0.306 0.0736 0.0398 0.0396 0.0371 0.0985 0.108 0.112 0.0561 0.0692 0.0452 0.0378 0.365 0.0736 0.035 0.0369 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1313 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 107 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-006F Proiect: YANKO1204 Sample ID: 167014032 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-007F 167014033 SE 14-JUN-06 13-JUL-06 Client 18.1%Proicet: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Rad Gamma Spec Analysis Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.02 +/-0.149 Americium-241 U 0.0755 +/-0.0992 Bismuth-212 0.749 +/-0.237 Bismuth-214 0.881 +/-0.074 Cesium-134 UI 0.00 +/-0.0374 Cesium-137 0.161 +/-0.0323 Cobalt-60 0.217 +/-0.0418 Europium-152 U 0.000731 +/-0.0462 Europium-154 U 0.00239 +/-0.0511 Europium-155 U 0.0642 +/-0.0483 Lead-212 0.980 +/-0.0532 Lead-214 0.897 +/-0.0753 Manganese-54 U 0.021 +/-0.0227 Niobium-94 U 0.00761 +/-0.0157 Potassium-40 11.4 +/-0.679 Radium-226 0.881 +/-0.074 Silver-108m U 0.0116 +/-0.0145 Thallium-208 0.327 +/-0.0375 0.0511 0.0892 0.111 0.0237 0.0205 0.0142 0.0137 0.0393 0.0435 0.0468 0.0223 0.0277 0.0147 0.0138 0.136 0.0237 0.0135 0.0146+/-0.149+/-0.0992+/-0.237+/-0.074+/-0.0374+/-0.0323+/-0.0418+/-0.0462+1-0.0511+/-0.0483+/-0.0532+/-0.0753+/-0.0227+/-0.0157+/-0.679+/-0.074+/-0.0145+/-0.0375 0.108 0.183 0.233 0.0498 0.0427 0.0298 0.0297 0.0814 0.0933 0.0958 0.0459 0.0573 0.031 0.0288 0.296 0.0498 0.028 0.0305 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1313 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 109 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-007F Project: YANKO 1204 Sample ID: 167014033 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.110 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-008F 167014034 SE 14-JUN-06 13-JUL-06 Client 15%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.29 +/-0.282 Americium-241 U 0.0334 +/-0.0374 Bismuth-212 0.826 +/-0.456 Bismuth-214 0.912 +/-0.170 Cesium-134 UI 0.00 +/-0.0452 Cesium-137 0.0966 +/-0.0486 Cobalt-60 0.160 +/-0.0565 Europium-152 U -0.0351 +/-0.0698 Europium-154 U -0.058 +/-0.0905 Europium-155 U 0.107 +/-0.0907 Lead-212 1.15 +/-0.152 Lead-214 0.979 +/-0.147 Manganese-54 U 0.0108 +/-0.026 Niobium-94 U -0.00244 +/-0.0276 Potassium-40 13.6 +/-1.32 Radium-226 0.912 +/-0.170 Silver-108m U -0.0142 +/-0.0237 Thallium-208 0.372 +/-0.0669 0.0814 0.0341 0.188 0.0419 0.0345 0.0251 0.0227 0.0589 0.0693 0.0553 0.033 0.0448 0.0256 0.0226 0.181 0.0419 0.0194 0.0239+/-0.282+/-0.0374+/-0.456+/-0.170+/-0.0452+/-0.0486+/-0.0565+/-0.0698+/-0.0905+/-0.0907+/-0.152+/-0.147+/-0.026+/-0.0276+/-1.32+/-0.170+/-0.0237+/-0.0669 0.176 0.070 0.402 0.0894 0.0729 0.0534 0.0506 0.124 0.153 0.114 0.0688 0.0939 0.055 0.0482 0.414 0.0894 0.0412 0.0509 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1314 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported ill GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-008F Project: YANKO 1204 Sample ID: 167014034 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.112 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-008FS 167014035 SE 14-JUN-06 13-JUL-06 Client 16.3%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganmna,Solid-FSS GAAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.12 U 0.00392 0.776 0.850 U 0.0541 U 0.0382 0.0529 U -0.0463 U 0.0632 U 0.0179 1.03 1.01 U 0.00536 U -0.0157 11.9 0.850 U 0.00128 0.351+/-0.198+/-0.109+/-0.380+/-0.112+/-0.0425+/-0.0431+/-0.0441+/-0.0722+/-0.0637+/-0.0651+/-0.0781+/-0.128+/-0.0296+/-0.0243+/-1.02+/-0.112+/-0.0233+/-0.0549 0.0636 0.0938 0.144 0.0375 0.0294 0.0228 0.0202 0.0591 0.0687 0.0608 0.0386 0.0409 0.0254 0.0199 0.182 0.0375 0.0196 0.0201+/-0.198+/-0.109+/-0.380+/-0.112+/-0.0425+/-0.0431+/-0.0441+/-0.0722+/-0.0637+/-0.0651+/-0.0781+/-0.128+/-0.0296+/-0.0243+/-1.02+/-0.112+/-0.0233+/-0.0549 0.139 0.194 0.313 0.080 0.0624 0.0486 0.0452 0.124 0.150 0.126 0.0798 0.086 0.0543 0.0424 0.412 0.080 0.0413 0.043 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1314 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 113 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-008FS Project: YANKO 1204 Sample ID: 167014035 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.114 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-014F 167014036 SE 14-JUN-06 13-JUL-06 Client 17.6%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 +/-0.283 Americium-241 U -0.0255 +/-0.0431 Bismuth-212 1.25 +/-0.543 Bismuth-214 1.15 +/-0.145 Cesium-134 UI 0.00 +/-0.0608 Cesium-137 U 0.0147 +/-0.0307 Cobalt-60 U 0.0113 +/-0.0335 Europium-152 U -0.0581 +/-0.0742 Europium-154 U -0.0157 +/-0.119 Europium-155 U 0.0565 +/-0.0989 Lead-212 0.968 +/-0.0889 Lead-214 1.09 +/-0.131 Manganese-54 U 0.0265 +/-0.034 Niobium-94 U 0.035 +/-0.0305 Potassium-40 12.1 +1-1.05 Radium-226 1.15 +/-0.145 Silver-108m U -0.00664 +/-0.0249 Thallium-208 0.339 +/-0.0665 0.0995 0.0366 0.217 0.0412 0.0348 0.0269 0.0289 0.0594 0.0844 0.0557 0.0496 0.0476 0.0298 0.0276 0.245 0.0412 0.0217 0.0264+/-0.283+/-0.0431+/-0.543+/-0.145+/-0.0608+/-0.0307+/-0.0335+/-0.0742+/-0.119+/-0.0989+/-0.0889+/-0.131+/-0.034+/-0.0305+1-1.05+/-0.145+/-0.0249+/-0.0665 0.211 0.0752 0.459 0.0875 0.0733 0.0568 0.0625 0.124 0.181 0.115 0.102 0.0992 0.0631 0.0578 0.536 0.0875 0.0455 0.0557 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1314 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AIXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 115 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-014F Proiect: YANK01204 Sample ID: 167014036 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.116 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-015F 167014037 SE 14-JUN-06 13-JUL-06 Client 19.1%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,So/id-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.907 +/-0.180 Americium-241 U -0.0109 +/-0.0265 Bismuth-212 0.721 +/-0.302 Bismuth-214 0.894 +/-0.0964 Cesium-134 U 0.0333 +/-0.0342 Cesium-137 0.0585 +/-0.026 Cobalt-60 0.168 +/-0.0605 Europium-152 U -0.00396 +/-0.0504 Europium-154 U -0.0102 +/-0.0675 Europium-155 0.108 +/-0.0598 Lead-212 1.08 +/-0.0636 Lead-214 0.959 +/-0.0922 Manganese-54 U 0.0295 +/-0.0244 Niobium-94 U 0.0358 +/-0.0341 Potassium-40 11.9 +/-0.898 Radium-226 0.894 +/-0.0964 Silver-108m U 0.00216 +/-0.0195 Thallium-208 0.358 +/-0.0474 0.0634 0.0237 0.139 0.0322 0.0251 0.0189 0.0213 0.0431 0.0558 0.0345 0.0264 0.0306 0.0224 0.0188 0.125 0.0322 0.0153 0.0171+/-0.180+/-0.0265+/-0.302+/-0.0964+/-0.0342+/-0.026+/-0.0605+/-0.0504+/-0.0675+/-0.0598+/-0.0636+/-0.0922+/-0.0244+/-0.0341+/-0.898+/-0.0964+/-0.0195+/-0.0474 0.136 0.0487 0.297 0.0683 0.0531 0.0402 0.0463 0.0903 0.122 0.0715 0.0547 0.0642 0.0475 0.0397 0.286 0.0683 0.0323 0.0364 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1315 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 117 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-015F Project: YANK01204 Sample ID: 167014037 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.118 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-02OF 167014038 SE 14-JUN-06 13-JUL-06 Client 18.6%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04 +/-0.274 Americium-241 U 0.0311 +/-0.0446 Bismuth-212 0.897 +/-0.422 Bismuth-214 1.13 +/-0.134 Cesium-134 U 0.0635 +/-0.0584 Cesium-137 U 0.0594 +/-0.0467 Cobalt-60 U 0.066 +/-0.0684 Europium-152 U -0.0434 +/-0.0738 Europium-154 U 0.0705 +/-0.102 Europium-155 U 0.0387 +/-0.0639 Lead-212 1.17 +/-0.089 Lead-214 1.14 +/-0.139 Manganese-54 U 0.0245 +/-0.0341 Niobium-94 U 0.0146 +/-0.0294 Potassium-40 13.4 +/-1.19 Radium-226 1.13 +/-0.134 Silver-108m U -0.0103 +/-0.0246 Thallium-208 0.324 +/-0.0722 0.0894 0.0379 0.197 0.0475 0.0352 0.029 0.0315 0.0637 0.0917 0.0584 0.0342 0.0461 0.0301 0.0257 0.217 0.0475 0.0209 0.0274+/-0.274+/-0.0446+/-0.422+/-0.134+/-0.0584+/-0.0467+/-0.0684+/-0.0738+/-0.102+/-0.0639+/-0.089+/-0.139+/-0.0341+/-0.0294+/-1.19+/-0.134+/-0.0246+/-0.0722 0.193 0.0779 0.421 0.101 0.0746 0.0614 0.0685 0.133 0.198 0.121 0.0712 0.0965 0.0642 0.0545 0.489 0.101 0.0442 0.058 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1315 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 119 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-020F Proiect: YANKO 1204 Sample ID: 167014038 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.120 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.corn C-r4fQ*nf A n~ah~ei~.L.t LI~J~..#.4LL, ~.Ik I~IZ~4R V ~Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-026F 167014039 SE 14-JUN-06 13-JUL-06 Client 17.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.504 +1-0.152 Americium-241 U 0.0361 +/-0.0587 Bismuth-212 U 0.179 +/-0.207 Bismuth-214 0.332 +/-0.0942 Cesium-134 U 0.0254 +/-0.0299 Cesium-137 0.120 +/-0.0629 Cobalt-60 0.152 +/-0.0476 Europium-152 U 0.0321 +/-0.0675 Europium-154 U -0.0428 +/-0.0668 Europium-155 U -0.0162 +/-0.0637 Lead-212 0.592 +/-0.0845 Lead-214 0.520 +/-0.104 Manganese-54 U 0.0155 +/-0.0247 Niobium-94 U -0.0157 +/-0.022 Potassium-40 4.92 +/-0.759 Radium-226 0.332 +/-0.0942 Silver-108m U -0.00793 +/-0.0213 Thallium-208 UI 0.00 +/-0.0472 0.0691 0.0511 0.188 0.0416 0.027 0.0207 0.0202 0.0531 0.0495 0.0519 0.0301 0.0385 0.0221 0.0179 0.167 0.0416 0.0173 0.0335+/-0.152+/-0.0587+/-0.207+/-0.0942+/-0.0299+/-0.0629+/-0.0476+/-0.0675+/-0.0668+/-0.0637+/-0.0845+/-0.104+/-0.0247+/-0.022+/-0.759+/-0.0942+/-0.0213+/-0.0472 0.149 0.106 0.398 0.0877 0.0573 0.044 0.0445 0.111 0.111 0.108 0.0627 0.0807 0.0472 0.0383 0.375 0.0877 0.0366 0.0695 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 1316 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 121 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-026F 167014039 Project: YANKO 1204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.122 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-027F 167014040 SE 14-JUN-06 13-JUL-06 Client 13.3%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gannna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.902 U 0.0569 0.461 0.620 UI 0.00 0.166 0.469 U 0.0305 U -0.00276 U -0.0141 0.692 0.641 U -0.00134 U -0.00979 10.7 0.620 U -0.0101 0.181+/-0.178+/-0.0778+/-0.256+/-0.0941+/-0.0338+/-0.0402+/-0.0561+/-0.0746+/-0.075+/-0.0697+/-0.0798+/-0.109+/-0.023+/-0.0191+/-0.999+/-0.0941+/-0.0182+/-0.0544 0.0632 0.0561 0.145 0.0326 0.0221 0.019 0.0174 0.047 0.0537 0.0499 0.0289 0.0317 0.0199 0.0163 0.163 0.0326 0.0153 0.0183+/-0.178+/-0.0778+/-0.256+/-0.0941+/-0.0338+/-0.0402+/-0.0561+/-0.0746+/-0.075+/-0.0697+/-0.0798+/-0.109+/-0.023+/-0.0191+/-0.999+/-0.0941+/-0.0182+/-0.0544 0.126 0.112 0.290 0.0651 0.0441 0.0379 0.0347 0.094 0.107 0.0997 0.0578 0.0634 0.0398 0.0326 0.326 0.0651 0.0306 0.0366 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 07/27/06 1311 548622 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1625 547815 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 123 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-027F 167014040 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.124 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: 9106-0014-027FS Proiect: YANKO 1204 Sample ID: 167014041 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 14-JUN-06 Receive Date: 13-JUL-06 Collector:

Client Moisture:

14.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.669 +/-0.185 Americium-241 U 0.00992 +/-0.0241 Bismuth-212 0.476 +/-0.275 Bismuth-214 0.593 +/-0.111 Cesium-134 UI 0.00 +/-0.0347 Cesium-137 0.115 +/-0.0333 Cobalt-60 0.394 +/-0.0581 Europium-152 U 0.0198 +/-0.0438 Europium-154 U 0.0154 +/-0.0596 Europium-155 U 0.0672 +1-0.0605 Lead-212 0.690 +/-0.092 Lead-214 0.709 +/-0.102 Manganese-54 U 0.00905 +/-0.0208 Niobium-94 U 0.00339 +/-0.0184 Potassium-40 10.5 +/-0.927 Radium-226 0.593 +/-0.111 Silver-108m U -0.0126 +/-0.0157 Thallium-208 0.241 +/-0.0442 0.0674 0.023 0.112 0.0309 0.022 0.0176 0.0143 0.0403 0.0515 0.0347 0.0228 0.028 0.0188 0.0158 0.126 0.0309 0.0132 0.0189+/-0.185+/-0.0241+/-0.275+/-0.111+/-0.0347+/-0.0333+/-0.0581+/-0.0438+/-0.0596+/-0.0605+/-0.092+/-0.102+/-0.0208+/-0.0184+/-0.927+/-0.111+/-0.0157+/-0.0442 0.143 0.0471 0.240 0.0651 0.0462 0.037 0.0317 0.0841 0.111 0.0716 0.0472 0.0586 0.0397 0.0332 0.282 0.0651 0.0278 0.0396 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 0659 548625 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 125 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-027FS Project: YANK01204 Sample ID: 167014041 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.126 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Cirtifirnti-nf Annlv-ik Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033F 167014042 SE 14-JUN-06 13-JUL-06 Client 20.7%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.809 +/-0.226 Americium-241 U 0.175 +/-0.132 Bismuth-212 U 0.251 +/-0.379 Bismuth-214 0.652 +/-0.135 Cesium-134 UI 0.00 +/-0.0683 Cesium-137 1.36 +/-0.100 Cobalt-60 2.07 +/-0.129 Europium-152 U -0.0146 +/-0.0782 Europium-154 U 0.0751 +/-0.0951 Europium-155 U 0.00977 +/-0.072 Lead-212 0.951 +/-0.0824 Lead-214 0.714 +/-0.107 Manganese-54 U -0.019 +/-0.0382 Niobium-94 U -0.00464 +/-0.0296 Potassium-40 13.4 +/-1.03 Radium-226 0.652 +/-0.135 Silver-108m U 0.0324 +/-0.0279 Thallium-208 0.294 +/-0.053 0.111 0.0903 0.200 0.0494 0.0361 0.026 0.0265 0.065 0.0846 0.0607 0.0362 0.0472 0.0307 0.0246 0.215 0.0494 0.0244 0.0269+/-0.226+/-0.132+/-0.379+/-0.135+/-0.0683+/-0.100+/-0.129+/-0.0782+/-0.0951+/-0.072+/-0.0824+/-0.107+/-0.0382+/-0.0296+/-1.03+/-0.135+/-0.0279+/-0.053 0.233 0.186 0.421 0.103 0.0753 0.0547 0.0573 0.135 0.181 0.125 0.0747 0.0979 0.0643 0.0515 0.472 0.103 0.0506 0.0563 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 07/27/06 0659 548625 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 127 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033F Project: YANK01204 Sample ID: 167014042 Client ID: YANK00I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.128 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-038F 167014043 SE 09-JUN-06 13-JUL-06 Client 16.8%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.232 Curium-242 U 0.0315 Curium-243/244 U 0.0465 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0221 Plutonium-239/240 U 0.0129 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 0.00 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.29 Americium-241 U 0.0522 Bismuth-212 0.727 Bismuth-214 0.991 Cesium-134 U 0.0456 Cesium-137 0.347 Cobalt-60 1.60 Europium-152 U -0.0166 Europium-154 U 0.0796 Europium-155 UI 0.00 Lead-212 1.28 Lead-214 1.11 Manganese-54 U 0.0532 Niobium-94 U -0.00356 Potassium-40 14.5 Radium-226 0.991 Silver-108m U -0.00196 Thallium-208 0.380 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0194 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -1.16+/-0.156+/-0.0617+/-0.0742 0.030 0.00 0.0301+/-0.159+/-0.0618+/-0.0745+/-0.0953 0.0742 +/-0.0954+/-0.0977 0.0908 +/-0.0977+/-8.82 7.40 +/-8.82+/-0.235+/-0.110+/-0.433+/-0.106+/-0.0517+/-0.0492+/-0.101+/-0.0616+/-0.0797+/-0.105+/-0.0788+/-0.104+/-0.0333+/-0.0236+/-1.00+/=0.106+/-0.0223+/-0.059 0.0886 0.0876 0.174 0.0395 0.029 0.0201 0.021 0.0526 0.0719 0.0529 0.0322 0.0375 0.0296 0.0193 0.162 0.0395 0.019 0.0213+/-0.235+/-0.110+/-0.433+/-0.106+/-0.0517+/-0.0492+/-0.101+/-0.0616+/-0.0797+/-0.105+/-0.0788+/-0.104+/-0.0333+/-0.0236+/-1.00+/-0.106+/-0.0223+/-0.059 0.131 0.0853 0.132 0.273 0.306 15.4 0.186 0.179 0.366 0.0825 0.0606 0.0422 0.0454 0.109 0.153 0.109 0.0664 0.0779 0.0616 0.0405 0.358 0.0825 0.0395 0.0446 0.0353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWI 07/21/06 0742 548404 1 LCWI 07/20/06 0954 548405 2 LCWI 07/24/06 1249 548406 3 MJI-l 07/27/06 0700 548625 4 BXF1 07/22/06 1243 548637 5 NXPI 07/22/062023 547901 6+/-0.0176 0.0155 +/-0.0176+/-7.95 6.74 +/-7.95 14.3 pCi/g 129 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certi cateof Anaksis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-038F 167014043 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAIlFSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0916+/-0.108 0.0896 +/-0.108 0.182 pCi/g pCi/g 11.6 +/-23.8 18.7 +/-23.9 39.2 ATH2 07/20/06 1719 547902 7 MXPI 07/21/06 2307 548412 8 MXPI 07/23/06 0914 548413 9 EGDI 07/27/06 0201 547825 10 6.82 +/-6.21 5.04 +/-6.22 10.3 pCi/g 0.271 +/-0.244 0.197 +/-0.244 0.406 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B PD 07/14/06 0748 547923 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-R 2 DOE EML HASL-300, Pu-1I1-R(3 DOE EML HASL-300, Pu-lIl-R(4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-0 I Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-I, Modified 10 DOE EML HASL-300, Tc-02-RC C Modified-Modified Modified Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Recovery%87 62 85 64 67 72 Acceptable Limits (15%o-125%)

(15%-/125%)

(25%-/125%)

(25%- 125%)(150/o-125%)

(25%-125%)

130 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-038F Project: YANKO1204 Sample ID: 167014043 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 84 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.131 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-037F 167014044 SE 13-JUN-06 13-JUL-06 Client 14.3%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0392 Curium-242 U 0.00 Curium-243/244 U -0.00521 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.00 Plutonium-239/2 4 0 U 0.0155 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 1.66 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth+/-0.0616+/-0.0499+/-0.0102 0.0246 0.00 0.0247+/-0.0618+/-0.0499+/-0.0102 0.108 0.069 0.108 0.0555 0.102 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.0401 0.00 +/-0.0401+/-0.0412 0.0233 +/-0.0413+/-10.4 8.70 +1-10.5 18.1 pCi/g Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 0.840 U 0.0508 U 0.301 0.583 U 0.0428 0.326 1.23 U 0.027 U 0.00101 U 0.0497 0.517 0.542 U 0.0333 U -0.0136+/-0.217+/-0.0508+/-0.339+/-0.108+/-0.0345+/-0.0594+/-0.0913+/-0.0591+/-0.0759+/-0.0682+/-0.0722+/-0.0969+/-0.0265+/-0.0232+/-0.832+/-0.108+/-0.0212+/-0.0538 0.0879 0.0262 0.189 0.0404 0.0291 0.0222 0.0186 0.0513 0.0639 0.0418 0.0346 0.0373 0.0237 0.019 0.167 0.0404 0.0185 0.0215+/-0.217+/-0.0508+/-0.339+/-0.108+/-0.0345+/-0.0594+/-0.0913+/-0.0591+/-0.0759+/-0.0682+/-0.0722+/-0.0969+/-0.0265+/-0.0232+/-0.832+/-0.108+/-0.0212+/-0.0538 0.184 0.0537 0.394 0.0843 0.0607 0.0465 0.0405 0.107 0.137 0.086 0.071 0.0773 0.0498 0.0399 0.365 0.0843 0.0386 0.045 0.0374 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCW1 07/21/06 0742 548404 1 LCWI 07/20/06 0954 548405 2 LCWI 07/24/06 1305 548406 3 MJH 1 07/27/06 0700 548625 4 BXF1 07/22/06 1243 548637 5 NXPI 07/25/06 1948 547901 6 Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting 9.76 0.583 0.00867 0.231 GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.(Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U)125 +/-0.012 0.0166 +/-0.012 5.03 +/-8.25 6.67 +/-8.25 14.0 pCi/g 132 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-037F 167014044 Project: YANKO 1204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AllFSS Carbon- 14 Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 +/-0.103 0.0844 +/-0.103-5.36 +/-22.0 17.9 +/-22.0 1.58 +/-5.96 4.96 +/-5.96 0.158 +/-0.261 0.214 +/-0.261 0.171 37.6 10.2 0.441 pCi/g pCi/g pCi/g pCi/g ATH2 07/20/06 1853 547902 7 MXPI 07/21/06 2323 548412 8 MXPI 07/23/06 1001 548413 9 EGDI 07/27/06 0217 547825 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B PD 07/14/06 0748 547923 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 .1632 547819 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-I, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 85 97 76 65 75 76 (15%-125%)

(15%-125%)

(25%-I125%)

(25%- 125%)(15%--125%)

(25%-6125%)

133 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-037F Project: YANK01204 Sample ID: 167014044 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 82 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.134 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr, Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-018F 167014045 SE 06-JUN-06 13-JUL-06 Client 21.7%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0665 Curium-242 U -0.00841 Curium-243/244 U 0.022 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0719 Plutonium-239/240 U 0.0396 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.40 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.06 Americium-241 U -0.0288 Bismuth-212 0.479 Bismuth-214 0.946 Cesium-134 Ut 0.00 Cesium-137 0.293 Cobalt-60 0.895 Europium-152 U -0.0413 Europium-154 U 0.00575 Europium-155 Ut 0.00 Lead-212 1.14 Lead-214 1.09 Manganese-54 U 0.0177 Niobium-94 U -0.0096 Potassium-40 12.2 Radium-226 0.946 Silver-108m U 0.00662 Thallium-208 0.357 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00642 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -1.21+/-0.101+/-0.0165+/-0.0585 0.057 0.0399 0.0331+/-0.102+/-0.0165+/-0.0586 0.192 0.175 0.145 0.130 0.154 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.0893 0.0297 +/-0.0897+/-0.0742 0.0419 +/-0.0743+/-7.83 6.30 +/-7.86 13.1 pCi/g+/-0.182+/-0.101+/-0.200+/-0.106+/-0.0323+/-0.0408+/-0.082+/-0.0444+/-0.0497+/-0.0636+/-0.119+/-0.125+/-0.0191+/-0.0159+/-1.03+/-0.106+/-0.0147+/-0.0492 0.0522 0.0918 0.112 0.0269 0.0196 0.0145 0.0134 0.0352 0.0421 0.0394 0.022 0.0261 0.0165 0.013 0.102 0.0269 0.013 0.0133+/-0.182+/-0.101+/-0.200+/-0.106+/-0.0323+/-0.0408+/-0.082+/-0.0444+/-0.0497+/-0.0636+/-0.119+/-0.125+/-0.0191+/-0.0159+/-1.03+/-0.106+/-0.0147+/-0.0492 0.109 0.188 0.232 0.0555 0.0406 0.030 0.0286 0.0726 0.0888 0.0806 0.045 0.0537 0.0341 0.0269 0.220 0.0555 0.0268 0.0276 0.0386 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCW1 07/21/06 0742 548404 1 LCWI 07/20/06 0954 548405 2 LCW1 07/24/06 1322 548406 3 MJHI 07/27/06 0701 548625 4 BXFI 07/26/06 1703 548637 5 NXPI 07/22/06 2056 547901 6+/-0.014 0.0172 +/-0.014+/-6.75 5.73 +/-6.75 12.1 pCi/g 135 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-018F 167014045 Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AIIFSS Carbon- 14 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.190 +/-0.113 0.0921 +/-0.113 0.187 pCi/g pCi/g-7.93 +/-20.7 16.9 +/-20.7 35.4 ATH2 07/22/06 0346 547902 7 MXPI 07/21/06 2339 548412 8 MXP1 07/23/06 1048 548413 9 EGD1 07/27/06 0234 547825 10-2.69 +/-6.16 5.24 +/-6.16 10.8 pCi/g 0.324 +/-0.243 0.195 +/-0.243 0.401 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B PD 07/14/06 0748 547923 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 89 105 98 55 83 67 (15%-125%)

(15%-125%)

(25%-.125%)

(25%- 125%)(15%/o-125%)

(25%-0125%)

136 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.con Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-018F Proiect: YANKO1204 Sample ID: 167014045 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 84 (15%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.137 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-01 IF 167014046 SE 09-JUN-06 13-JUL-06 Client 18.9%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U Curium-243/244 U Alphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis 0.0361 0.00 0.0676 0.0211 0.152+/-0.0966+/-0.158+/-0.132 0.00 +/-0.0967 0.00 +/-0.158 0.00 +/-0.133 0.182 0.218 0.183 0.241 0.202 13.5+/-0.084 0.0654 +/-0.084+/-0.160 0.0462 +/-0.161 3.48 +/-7.88 6.47 +/-7.89 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.350 Americium-241 U -0.00879 Bismuth-212 U 0.028 Bismuth-214 0.403 Cesium-134 U 0.0159 Cesium-137 U 0.0356 Cobalt-60 U 0.00576 Europium-152 U -0.0267 Europium-154 U 0.047 Europium-155 U -0.0158 Lead-212 0.474 Lead-214 0.403 Manganese-54 U -0.00744 Niobium-94 U -0.00552 Potassium-40 7.98 Radium-226 0.403 Silver-108m U 0.0155 Thallium-208 0.146 Rad Gas Flow Proportional Counting GFPC, S90, solid-ALL FSS Strontium-90 U 0.0133 d Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.24+/-0.169+/-0.037+/-0.287+/-0.094+/-0.0254+/-0.0348+/-0.020+/-0.0465+/-0.0658+/-0.0424+/-0.0538+/-0.0693+/-0.0224 P/-0.0177+/-0.725+/-0.094+/-0.0153/-0.0427 0.0708 0.0248 0.137 0.0289 0.0202 0.0183 0.0175 0.0409 0.0601 0.0384 0.0233 0.031 0.0182 0.0147 0.129 0.0289 0.0145 0.0167+/-0.169+/-0.037+/-0.287+/-0.094+/-0.0254+/-0.0348+/-0.020+/-0.0465+/-0.0658+/-0.0424+/-0.0538+/-0.0693+/-0.0224+/-0.0177+/-0.725+/-0.094+/-0.0153+/-0.0427 0.151 0.0509 0.292 0.0616 0.0432 0.0389 0.0387 0.0857 0.130 0.0794 0.0485 0.0648 0.0391 0.0315 0.294 0.0616 0.0307 0.0355 0.044 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWI 07/21/06 0754 548404 1 LCW1 07/20/06 0954 548405 2 LCW1 07/24/06 1338 548406 3 MJH1 07/27/06 0701 548625 4 BXFI 07/22/06 1243 548637 5 NXPI 07/22/06 2112 547901 6-/-0.0199 0.0194 +/-0.0199+/-6.88 5.54 +/-6.88 11.7 pCi/g 138 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: 9106-0014-01IF 167014046 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U-0.0864 +/-0.0976 0.0831 +/-0.0976 2.48 +/-20.3 16.1 +/-20.3 5.37 +/-6.00 4.89 +/-6.00 0.393 +/-0.259 0.207 +/-0.259 0.168 33.9 10.0 0.425 pCi/g pCi/g pCi/g pCi/g ATH2 07/20/06 2159 547902 7 MXP1 07/21/06 2355 548412 8 MXPI 07/23/06 1135 548413 9 EGDI 07/27/06 0250 547825 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B PD 07/14/06 0748 547923 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1I-RC Modified 3 DOE EML HASL-300, Pu- I -RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 43 76 97 56 81 80 (15/-,125%)

(15%-125%)

(25%-/125%)

(25%-125%)

(150/o7-125%)

(25%/- 125%)139 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-01 IF Project: YANK01204 Sample ID: 167014046 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%/-,125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.U1 Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.140 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-003F 167014047 SE 14-JUN-06 13-JUL-06 Client 16.9%Project: Client ID: Vol. Recv.: YANKO1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0358 Curiuni-242 U 0.00 Curiun-243/244 U 0.00 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.107 Plutonium-239/240 U 0.0499 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 0.867 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth F/-0.0688+/-0.0562 k/-0.0481 0.0394 0.00 0.00+/-0.069+/-0.0562+/-0.0481 0.145 0.0777 0.0665 0.141 0.141 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.112 0.0323 +/-0.113 F/-0.0796 0.0323 +/-0.0799+/-8.07 6.74 +/-8.07 14.1 pCi/g Waived Actinium-228 1.12 Americium-241 U 0.0756 Bismuth-212 0.829 Bismuth-214 0.993 Cesium-134 U 0.035 Cesium-137 U3.950E-06 Cobalt-60 U 0.0115 Europium-152 U 0.0172 Europium-154 U 0.000581 Europium-155 U 0.0613 Lead-212 1.19 Lead-214 1.14 Manganese-54 U -0.00216 Niobium-94 U 0.0236 Potassium-40 12.4 Radium-226 0.993 Silver-108m U -0.00529 Thallium-208 0.361 Rad Gas Flow Proportional Counting+/-0.141+/-0.125+/-0.238+/-0.0896+/-0.0293+/-0.020+/-0.0168+/-0.0452+/-0.0524+/-0.0556+/-0.0621+/-0.0846+/-0.0178+/-0.0164+/-0.718+/-0.0896+/-0.015+/-0.0447 0.0468 0.0869 0.115 0.0274 0.0205 0.0146 0.0147 0.0407 0.0433 0.052 0.0234 0.0271 0.0153 0.0148 0.119 0.0274 0.0128 0.0143+/-0.141+/-0.125+/-0.238+/-0.0896+/-0.0293+/-0.020+/-0.0168+/-0.0452+/-0.0524+/-0.0556+/-0.0621+/-0.0846+/-0.0178+/-0.0164+/-0.718+/-0.0896+/-0.015+/-0.0447 0.0993 0.179 0.242 0.0572 0.0426 0.0306 0.0315 0.0845 0.0924 0.107 0.0483 0.0564 0.0321 0.0308 0.259 0.0572 0.0267 0.0299 0.0469 13.8 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWI 07/21/06 0754 548404 1 LCW1 07/20/06 0954 548405 2 LCW1 07/24/06 1354 548406 3 MJH I 07/27/06 0702 548625 4 BXF1 07/22/06 1243 548637 5 NXPI 07/25/062010 547901 6 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.1 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0256 +/-0.0232 0.0208 +/-0.0232 3.97 +/-8.07 6.57 +/-8.07 141 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certificateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: July 28, 2006 Client Sample ID: Sample ID: 9106-0014-003F 167014047 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd-0.0967 +/-0.0988 0.0843 +/-0.0989 0.171 29.4 pCi/g pCi/g-1.58 +/-17.5 14.0 +/-17.5 3.03 +/-7.13 5.91 +/-7.13 0.314 +/-0.261 0.210 +/-0.261 ATH2 07/20/06 2332 547902 7 MXPI 07/22/06 0012 548412 8 MXPI 07/23/06 1222 548413 9 EGD1 07/27/06 0306 547825 10 12.1 pCi/g 0.432 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B PD 07/14/06 0748 547923 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 07/13/06 1632 547819 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HIASL-300, Pu-I 1-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-0I Modified 8 DOE RESL Fe-I, Modified 9 DOE RESL Ni-l, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS 97 88 87 52 89 59 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

142 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: July 28, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-003F Proiect: YANK01204 Sample ID: 167014047 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (15%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.143 I QUALITY CONTROL DATA I I 144 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: July 28, 2006 Page 1 of 16 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

167014 Parmname Rad Alpha Spec Batch 548404 NOM Sample Qual QC Units RPD%REC% Range Anist Date Time QC1201136021 Americium-241 Curium-242 Curium-243/244 QC1201136023 Americium-241 167014043 DUP 0.232 Uncert: +/-0.156 TPU: +/-0.159 U 0.0315 Uncert: +/-0.0617 TPU: +/-0.0618 U 0.0465 Uncert: +/-0.0742 TPU: +/-0.0745 LCS Curium-242 Curium-243/244 QC1201136020 MB Americium-241 Curium-242 Curium-243/244 QC1201136022 167014043 MS Americium-241 Curium-242 Curium-243/244 9.39 Uncert: TPU: Uncert: TPU: 11.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.0831+/-0.136+/-0.137 U 0.00+/-0.104+/-0.104 U 0.00+/-0.0869+/-0.0869 9.37+/-0.923+/- 1.46 U 0.00+/-0.0472+/-0.0472 12.5+/-1.06+/- 1.84 U 0.0166+/-0.0431+/-0.0432 U 0.00+/-0.0421+/-0.0421 U 0.00+/-0.0414+/-0.0414 pCi/g 95 pCi/g 0 pCi/g 0 pCi/g (0% -100%) CWI 07/21/06 07:54 (0% -100%)(0%- 100%)100 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)

12.4 0.232 Uncert: +/-0.156 TPU: +/-0.159 U 0.0315 Uncert: +/-0.0617 TPU: +/-0.0618 15.1 U 0.0465 Uncert: +/-0.0742 TPU: +/-0.0745 U 12.2+/-1.16+/-1.86 0.00+/-0.0672+/-0.0672 15.2+/-1.30+/-2.23 97 (75%-125%)

101 (75%-125%)

Batch 548405 QC1201136025 167014043 DUP Plutonium-238 U -0.0221 U 0.0516 pCi/g 500 (0% -100%) iCWI 07/20/06 09:54 145 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 2 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 548405 Plutonium-239/240 QCI20H136027 LCS Plutoniurm-238 Plutonium-239/240 QC1201136024 MB Plutonium-238 Plutonium-239/240 QC1201136026 167014043 MS Plutonium-238 Uncert: +/-0.0953 TPU: +/-0.0954 U 0.0129 Uncert: +/-0.0977 TPU: +/-0.0977 Uncert: TPU: 8.68 Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0221 Uncert: +/-0.0953 TPU: +/-0.0954 11.4 U 0.0129 Uncert: +/-0.0977 TPU: +/-0.0977 U 0.00 Uncert: +/-8.82 TPU: +/-8.82+/-0.0716+/-0.0718 U -0.0248+/-0.0561+/-0.0561 U 0.0817+/-0.0858+/-0.0862 8.23+/-0.829+/-1.17 U 0.00+/-0.0654+/-0.0654 U 0.00267+/-0.103+/-0.103 pCi/g 634 (0% -100%)(75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 95 (75%-125%)

07/20/06 09:54 U Plutoniuin-239/240 Batch 548406 0.179+/-0.202+/-0.204 13.5+/-1.64+/-2.34-4.15+/-7.59+/-7.60 103+/-12.4+/-15.9 118 (75%-125%)

(75%-125%)

07/20/06 09:54 QC1201136029 167014043 DUP Plutonium-241 QC1201136031 LCS Plutonium-241 QC1201136028 MB Plutonium-241 QC1201136030 167014043 MS Plutonium-241 Rad Gamma Spec Batch 548621 QC1201136615 167014001 DUP Actinium-228 U pCi/g 0 (0% -100%) -CWI 124 Uncert: TPU: Uncert: TPU: 136 U Uncert: TPU: U -2.67+/-7.04+/-7.05 pCi/g pCi/g pCi/g 83 (75%-125%)

07/24/06 14:27 07/24/06 14:59 07/24/06 14:10 07/24/06 14:43 0.00+/-8.82+/-8.82 108+/-11.9+/-15.6 80 (75%-125%)

0.574 Uncert: +/-0.127 0.712+/-0.172+/-0.172 pCi/g 22 (0%- 100%) MJHI 07/26/06 18:59 146 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 3 of 16 Parmname NOM Samole Oual OC Units RPD%REC% Ranee AnIst Date Time Rad Gamma Spec Batch 548621 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.127 u 0.00885 U 0.0373 pCi/g 123 Uncert: +/-0.052 +/-0.0378 TPU: +/-0.052 +/-0.0378 0.314 UI 0.00 pCi/g 55 Uncert: +/-0.172 +/-0.411 TPU: +/-0.172 +/-0.411 0.418 0.441 pCi/g 5 Uncert: +/-0.073 +/-0.0861 TPU: +/-0.073 +/-0.0861 U 0.033 U 0.050 pCi/g 41 Uncert: +/-0.0236

+/-0.0408 TPU: +/-0.0236

+/-0.0408 0.117 0.155 pCi/g 28 Uncert: +/-0.0287

+/-0.0493 TPU: +/-0.0287

+/-0.0493 0.450 0.337 pCi/g 29 Uncert: +/-0.0518

+/-0.0574 TPU: +/-0.0518

+/-0.0574 U -0.0131 U -0.00971 pCi/g 30 Uncert: +/-0.0354

+/-0.0543 TPU: +/-0.0354

+/-0.0543 U 0.0169 U -0.0252 pCi/g 1010 Uncert: +/-0.0391

+/-0.0899 TPU: +/-0.0391

+/-0.0899 U 0.049 U 0.0455 pCi/g 7 Uncert: +/-0.0423

+/-0.0442 TPU: +/-0.0423

+/-0.0442 0.498 0.524 pCi/g 5 Uncert: +/-0.0576

+/-0.0595 TPU: +/-0.0576

+/-0.0595 0.494 0.436 pCi/g 13 Uncert: +/-0.0725

+/-0.087 TPU: +/-0.0725

+/-0.087 UI 0.00 U -0.0112 pCi/g 506 Uncert: +/-0.0342

+/-0.0265 TPU: +/-0.0342

+/-0.0265 u 0.000664 U -0.0145 pCi/g 219 Uncert: +/-0.0127

+/-0.0206 TPU: +/-0.0127

+/-0.0206 9.10 8.94 pCi/g 2 Uncert: +/-0.771 +/-1.04 TPU: +/-0.771 +/-1.04 0.418 0.441 pCi/g 5 Uncert: +/-0.073 +/-0.086 I TPU: +/-0.073 +/-0.0861 U 0.0108 U -0.00957 pCi/g 3370 Uncert: +/-0.0118

+/-0.0168 (0% -100%)(0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%-20%)(0%- 100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m 147 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

167014 Parmname Rad Gamma Spec Batch 548621 Thallium-208 QC1201136616 LCS Actinium-228 Americium-24 l Bismuth-212 Bisinuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample Qual 0C Page 4 of 16 REC% Ranse AnIst Date Time NOM Units RPD%TPU: Uncert: TPU: Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.60 Uncert: TPU: 14.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0118 0.179+/-0.032+/-0.032+/-0.0168 0.143+/-0.0374+/-0.0374 U -0.253+/-0.533+/-0.533 25.0+/-3.94+/-3.94 U 0.431+/- 1.02+/-1.02 U -0.116+/-0.244+/-0.244 U 0.0788+/-0.144+/-0.144 10.1+/-0.765+/-0.765 15.8+/-1.16+/-1.16 U -0.068+/-0.316+/-0.316 U 0.0112+/-0.312+/-0.312 U 0.0445+/-0.341+/-0.341 U 0.0469+/-0.178+/-0.178 U 0.103+/-0.222+/-0.222 U -0.0408+/-0.145+/-0.145 U 0.0574+/-0.113+/-0.113 U -0.444 pCi/g 22 (0%- 100%)pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 07/26/06 14:50 107 (75%-125%)

105 (75%-125%)

107 (75%-125%)

148 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 5 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 548621 Radium-226 Silver-I 08m Thallium-208 QC1201136614 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.13+/-1.13 U -0.116+/-0.244+/-0.244 U -0.0298+/-0.128+/-0.128 U -0.124+/-0.122+/-0.122 U 0.0412+/-0.0416+/-0.0416 U -0.00324+/-0.0238+/-0.0238 U 0.0636+/-0.0952+/-0.0952 U 0.0196+/-0.0232+/-0.0232 U 0.000609+/-0.0112+/-0.0112 U 0.00318+/-0.0103+/-0.0103 U 0.00102+/-0.0108+/-0.0108 U -0.0182+/-0.0303+/-0.0303 U 0.00504+/-0.0329+/-0.0329 U -0.0228+/-0.0269+/-0.0269 U 0.046+/-0.042+/-0.042 U 0.00274+/-0.0219+/-0.0219 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 07/26/06 17:50 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 149 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 6 of 16 Parmname Rad Gamma Spec Batch 548621 Manganese-54 NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Batch 548622 QCI201136624 Actinium-228 Americium-24 I Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 167014021 DUP UI 0.00 Uncert: +/-0.200 TPU: +/-0.200 U -0.00413 Uncert: +/-0.0314 TPU: +/-0.0314 U 0.332 Uncert: +/-0.329 TPU: +/-0.329 0.372 Uncert: +/-0.0942 TPU: +/-0.0942 U 0.0389 Uncert: +/-0.0289 TPU: +/-0.0289 0.120 Uncert: +/-0.0639 TPU: +/-0.0639 0.199 Uncert: +/-0.0569 TPU: +/-0.0569 U -0.0287 Uncert: +/-0.0614 TPU: +/-0.0614 U 0.0592 Uncert: +/-0.0853 TPU: +/-0.0853 U -0.00257 U 0.00738+/-0.0129+/-0.0129 U -0.00443+/-0.00997

+/-0.00997 U 0.129+/-0.127+/-0.127 U 0.0196+/-0.0232+/-0.0232 U 0.00979+/-0.0119+/-0.0119 U 0.00219+/-0.0207+/-0.0207 UI 0.00+/-0.167+/-0.167 U -0.0505+/-0.0734+/-0.0734 0.466+/-0.236+/-0.236 0.284+/-0.0772+/-0.0772 U 0.00593+/-0.0222+/-0.0222 0.132+/-0.044+/-0.044 0.229+/-0.0519+/-0.0519 U -0.0234+/-0.0556+/-0.0556 U 0.0364+/-0.0569+/-0.0569 U 0.0607 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0 pCi/g 170 pCi/g 34 pCi/g 27 pCi/g 147 pCi/g 9 pCi/g 14 pCi/g 20 pCi/g 48 pCi/g 218 (0% -100%) MJHI 07/27/06 13:13 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)150 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Page 7 of 16 Workorder:

167014 Parmname NOM Samnle Oual OC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 548622 w Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I 08m Thallium-208 QC1201136625 Actinium-228 Americium-241 Uncert: +/-0.0552 TPU: +/-0.0552 0.445 Uncert: +/-0.0792 TPU: +/-0.0792 0.412 Uncert: +/-0.122 TPU: +/-0.122 u -0.0239 Uncert: +/-0.0293 TPU: +/-0.0293 U 0.0106 Uncert: +/-0.0242 TPU: +/-0.0242 10.4 Uncert: +/-1.15 TPU: +/-1.15 0.372 Uncert: +/-0.0942 TPU: +/-0.0942 u -0.0133 Uncert: +/-0.0221 TPU: +/-0.0221 0.167 Uncert: +/-0.056 TPU: +/-0.056+/-0.073+/-0.073 0.441+/-0.0657+/-0.0657 0.344+/-0.0747+/-0.0747 U -0.00805+/-0.0201+/-0.0201 U 0.00586+/-0.0181+/-0.0181 9.08+/-0.919+/-0.919 0.284+/-0.0772+/-0.0772 U 0.00349+/-0.017+/-0.017 0.120+/-0.0447+/-0.0447 u 0.124+/-0.526+/-0.526 25.9+/-4.05+/-4.05 U 0.399+/-1.02+/-1.02 U 0.0225+/-0.238+/-0.238 U 0.0554+/-0.136+/-0.136 9.45+/-0.759+/-0.759 15.2+/-1.16+/-1.16 pCi/g I pCi/g 18 pCi/g 99 pCi/g 58 pCi/g 13 pCi/g 27 pCi/g 343 pCi/g 33 (0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0%-20%)(0%- 100%)(0%- 100%)(0%- 100%)LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.61 Uncert: TPU: 14.7 Uncert: TPU: pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 111 (75%-125%)

07/27/06 13:17 98 (75%-125%)

103 (75%-125%)

Cobalt-60 151 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 8 of 16 Parmname NOM Sample Qual OC Units RPD%REC% Range AnIst Date Time Rad Gamma Spec Batch 548622 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC1201136623 Actinium-228 Americium-241 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: U -0.04+/-0.323+/-0.323 U 0.101+/-0.310+/-0.310 U -0.268+/-0.334+/-0.334 U 0.0603+/-0.173+/-0.173 U -0.15+/-0.217+/-0.217 U -0.0344+/-0.141+/-0.141 U 0.00673+/-0.115+1-0.115 U -0.363+/- 1.42+/-1.42 U 0.0225+/-0.238+/-0.238 U -0.049+/-0.110+/-0.110 U 0.00186+/-0.129+/-0.129 U 0.0358+/-0.055+/-0.055 U -0.00169+/-0.0138+/-0.0138 U 0.0319+/-0.123+/-0.123 U 0.0232+/-0.0369+/-0.0369 U -0.00574+/-0.0157 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

MB 07/27/06 13:12 Bismuth-212 Bismuth-214 Cesium- 134 152 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 9 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 548622 TPU: +/-0.0157 Cesium- 137 U 0.00313 pCi/g Uncert: +/-0.0138 TPU: +/-0.0138 Cobalt-60 U -0.000663 pCi/g Uncert: +/-0.021 TPU: +/-0.021 Europium-152 U -0.0075 pCi/g Uncert: +/-0.0402 TPU: +/-0.0402 Europium-154 U -0.0169 pCi/g Uncert: +/-0.0474 TPU: +/-0.0474 Europium-155 U -0.00421 pCi/g Uncert: +/-0.0241 TPU: +/-0.0241 Lead-212 U 0.000656 pCi/g Uncert: +/-0.0315 TPU: +/-0.0315 Lead-214 U 0.0276 pCi/g Uncert: +/-0.0373 TPU: +/-0.0373 Manganese-54 U -0.00525 pCi/g Uncert: +/-0.0145 TPU: +/-0.0145 Niobium-94 U -0.0061 pCi/g Uncert: +/-0.0133 TPU: +/-0.0133 Potassium-40 U 0.238 pCi/g Uncert: +/-0.206 TPU: +/-0.206 Radium-226 U 0.0232 pCi/g Uncert: +/-0.0369 TPU: +/-0.0369 Silver- 108m U -0.0032 pCi/g Uncert: +/-0.0126 TPU: +/-0.0126 Thallium-208 U 0.0128 pCi/g Uncert: +/-0.017 TPU: +/-0.017 Batch 548625 QC1201136627 167014041 DUP Actinium-228 0.669 0.498 pCi/g 29 (0% -100%) MJHI 07/27/06 11:03 Uncert: +/-0.185 +/-0.300 TPU: +/-0.185 +/-0.300 Americium-241 U 0.00992 U 0.00722 pCi/g 32 (0%- 100%)Uncert: +/-0.0241

+/-0.0402 TPU: +/-0.0241

+/-0.0402 153 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 10 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 548625 Bismuth-212 0.476 0.604 pCi/g 24 (0% -100%)Uncert: +/-0.275 +/-0.452 TPU: +/-0.275 +/-0.452 Bismuth-214 0.593 0.659 pCi/g 11 (0% -100%)Uncert: +/-0.111 +/-0.125 TPU: +/-0.111 +/-0.125 Cesium-134 UI 0.00 U 0.0102 pCi/g 147 (0%- 100%)Uncert: +/-0.0347

+/-0.0401 TPU: +/-0.0347

+/-0.0401 Cesium-137 0.115 0.103 pCi/g 12 (0%- 100%)Uncert: +/-0.0333

+/-0.0558 TPU: +/-0.0333

+/-0.0558 Cobalt-60 0.394 0.436 pCi/g 10 (0%- 100%)Uncert: +/-0.0581

+/-0.0759 TPU: +/-0.0581

+/-0.0759 Europium-152 U 0.0198 U 0.0232 pCi/g 16 (0% -100%)Uncert: +/-0.0438

+/-0.0769 TPU: +/-0.0438

+/-0.0769 Europium-154 U 0.0154 U 0.0257 pCi/g 50 (0%- 100%)Uncert: +/-0.0596

+/-0.101 TPU: +/-0.0596

+/-0.101 Europium-155 U 0.0672 U 0.00506 pCi/g 172 (0% -100%)Uncert: +/-0.0605

+/-0.069 I TPU: +/-0.0605

+/-0.0691 Lead-212 0.690 0.581 pCi/g 17 (0% -20%)Uncert: +/-0.092 +/-0.0975 TPU: +/-0.092 +/-0.0975 Lead-214 0.709 0.523 pCi/g 30 (0% -20%)Uncert: +/-0.102 +/-0.128 TPU: +/-0.102 +/-0.128 Manganese-54 U 0.00905 U 0.0161 pCi/g 56 (0% -100%)Uncert: +/-0.0208

+/-0.0345 TPU: +/-0.0208

+/-0.0345 Niobium-94 U 0.00339 U 0.00816 pCi/g 83 (0% -100%)Uncert: +/-0.0184

+/-0.0274 TPU: +/-0.0184

+/-0.0274 Potassium-40 10.5 9.60 pCi/g 9 (0% -20%)Uncert: +/-0.927 +/-1.16 TPU: +/-0.927 +/-1.16 Radium-226 0.593 0.659 pCi/g I1 (0% -100%)Uncert: +/-0.111 +/-0.125 TPU: +/-0.111 +/-0.125 Silver-108m U -0.0126 U 0.0151 pCi/g 2290 (0%- 100%)Uncert: +/-0.0157

+/-0.0264 TPU: +/-0.0157

+/-0.0264 Thallium-208 0.241 0.229 pCi/g 5 (0%- 100%)Uncert: +/-0.0442

+/-0.082 TPU: +/-0.0442

+/-0.082 154 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 11 of 16 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 548625 QC1201136628 Actinium-228 Americium-241 Bismuth-212 LCS Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.61 Uncert: TPU: 14.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.258+/-0.563+/-0.563 25.3+/-0.591+/-0.591 U -0.0117+/-1.01+/-1.01 U 0.0328+/-0.217+/-0.217 U -0.0179+/-0.153+/-0.153 10.6+/-0.496+/-0.496 16.0+/-0.647+/-0.647 U -0.0985+/-0.280+/-0.280 U 0.067+/-0.293+/-0.293 U 0.0406+/-0.231+/-0.231 U -0.0342+/-0.140+/-0.140 U 0.022+/-0.199+/-0.199 U 0.0506+/-0.130+/-0.130 U -0.0201+/-0.117+/-0.117 U 0.238+/- 1.21+/-1.21 U 0.0328+/-0.217+/-0.217 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 110 (75%-125%)

108 (75%-125%)

108 (75%-125%)

07/27/06 10:05 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 (75%-125%)

155 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

167014 Page 12 of 16 Parmname NOM Samnie Oual OC Units RPD% REC% Ranue Anist Date Time Rad Gamma Spec Batch 548625 Silver- 108m Thallium-208 QC1201136626 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: U 0.0283+/-0.100+/-0.100 U 0.0139+/-0.124+/-0.124 U 0.0405+/-0.0402+/-0.0402 U 0.0103+/-0.0483+/-0.0483 U 0.122+/-0.0944+/-0.0944 U 0.00488+/-0.0231+/-0.0231 U 0.00571+/-0.0116+/-0.0116 U -0.00585+/-0.0111+/-0.0111 U -0.00348+/-0.0114+/-0.0114 U -0.0192+/-0.0286+/-0.0286 U -0.00836+/-0.0307+/-0.0307 U -0.0141+/-0.0266+/-0.0266 U 0.0124+/-0.0247+/-0.0247 U 0.0188+/-0.0373+/-0.0373 U -0.00829+/-0.0122+/-0.0122 U 0.00308+/-0.0103 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 07/27/06 09:05 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 156 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gelcorn QC Summary Workorder:

167014 Page 13 of 16 Parmname NOM Samnle Oual OC Units RPD%REC% Range Anist Date Time Parmname NOM Sample Clual Rad Gamma Spec Batch 548625 Potassium-40 TPU: Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0103 U 0.207+/-0.138+/-0.138 U 0.00488+/-0.0231+/-0.0231 U -0.0047+/-0.00917

+/-0.00917 U 0.0107+/-0.0167+/-0.0167 pCi/g pCi/g pCi/g pCi/g 548637 QC1201136661 167014045 DUP Strontium-90 QCI201136663 LCS Strontiurn-90 QC1201136660 MB Strontium-90 QC1201136662 167014045 MS Strontium-90 U -0.00642 Uncert: +/-0.014 TPU: +/-0.014 U 0.0106+/-0.0166+/-0.0166 1.31+/-0.135+/-0.138 pCi/g 0 (0%- 100%) BXFI 1.47 Uncert: TPU: Uncert: TPU: 1.57 U Uncert: TPU: U 0.0121+/-0.0165+/-0.0165 pCi/g pCi/g pCi/g 89 (75%-125%)

07/26/06 17:03 07/25/06 13:31 07/26/06 17:03 07/25/06 13:31-0.00642+/-0.014+/-0.014 1.32+/-0.136+/-0.139 84 (75%-125%)

Rad Liquid Scintillation Batch 547825 QC1201134547 167014045 DUP Technetium-99 QC1201134549 LCS Technetium-99 QC1201134546 MB Technetium-99 QC1201134548 167014045 MS Technetium-99 U 0.324 Uncert: +/-0.243 TPU: +/-0.243 12.0 Uncert: TPU: Uncert: TPU: U 0.129+/-0.247+/-0.247 9.60+/-0.428+/-0.480 U 0.198+/-0.216+/-0.216 10.0+/-0.461+/-0.514 pCi/g 0 (0% -100%) EGDI pCi/g pCi/g pCi/g 80 (75%-125%)

07/27/06 03:39 07/27/06 04:12 07/27/06 03:23 07/27/06 03:55 12.7 U Uncert: 0.324+/-0.243 79 (75%-125%)

157 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

167014 Parmname Rad Liquid Scintillation Batch 547825 Batch 547901 QC1201134746 167014043 DUP Tritium QCI201134748 LCS Tritium QC1201134745 MB Tritium QC1201134747 167014043 MS Tritium Batch 547902 QC1201134750 167014044 DUP Carbon- 14 QC1201134752 LCS Carbon- 14 QC1201134749 MB Carbon- 14 QC1201134751 167014044 MS Carbon-14 Batch 548412 QC1201136041 167014045 DUP Iron-55 QC1201136043 LCS Iron-55 QC1201136040 MB Iron-55 QC1201136042 167014045 MS NOM TPU: Uncert: TPU: QC Summary Page 14 of 16 Sample Qual QC Units RPD% REC% Range Anist Date Time+/-0.243 U -1.16 U -1.68 pCi/g 0 (0%- 100%) NXPI 07/25/06 20:31+/-7.95 +/-7.46+/-7.95 +/-7.46 49.1 Uncert: TPU: Uncert: TPU: 50.5 U Uncert: TPU: Uncert: TPU: 7.04 Uncert: TPU: Uncert: TPU: 16.7 Uncert: TPU: U Uncert: TPU: 563 Uncert: TPU: Uncert: TPU:-1.16+/-7.95+/-7.95 0.173+/-0.103+/-0.103 0.173+/-0.103+/-0.103-7.93+/-20.7+/-20.7 48.3+/-9.80+/-9.84 U 0.488+/-7.04+/-7.04 49.2+/-10.2+/-10.3 U 0.0836+/-0.0971+/-0.0971 6.96+/-0.179+/-0.209 U -0.293+/-0.133+/-0.133 16.4+/-0.426+/-0.497 U -7.2+/-20.2+/-20.2 531+/-48.5+/-104 U -9.7+/-29.9+/-30.0 pCi/g pCi/g pCi/g 97 (75%-125%)

98 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 70 (0% -100%) ATH2 99 (75%-125%)

07/22/06 22:34 07/22/06 21:45 07/22/06 22:17 07/21/06 02:38 07/21/06 05:43 07/22/06 05:19 07/21/06 04:11 07/22/06 00:44 07/22/06 01:17 07/22/06 00:28 97 (75%-125%)

0 (0% -100%) vIXPI 94 (75%-125%)

158 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 15 of 16 Parmname Rad Liquid Scintillation Batch 548412 NOM Sample Qual-7.93+/-20.7+/-20.7 QC Units RPD% REC% Range Anist Date Time Iron-55 645 U Uncert: TPU: 687+1-51.5+/-149 pCi/g 106 (75%-125%)

Batch 548413 QC1201136045 167014045 DUP Nickel-63 QC1201136047 LCS Nickel-63 QC1201136044 MB Nickel-63 QC1201136046 167014045 MS Nickel-63 Uncert: TPU: U -2.69+/-6.16+/-6.16 U 3.52+/-8.57+/-8.57 pCi/g 0 (0% -100%) vAXP1 07/23/06 13:56 531 Uncert: TPU: Uncert: TPU: 551 U Uncert: TPU: 416+/-14.3+/-19.5 U 2.47+/-5.27+/-5.27 pCi/g pCi/g pCi/g 79 (75%-125%)

07/23/06 15:30 07/23/06 13:09 07/23/06 14:43-2.69+/-6.16+/-6.16 471+/-15.2+/-21.5 86 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:*A B BD C D H J N/A R U UI X Y A h A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded 159 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

167014 Page 16 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Anlst Date Time Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.160 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170683 SDG: 170683 September 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on August 17, 2006, July 07, 2006, July 13, 2006, July 21, 2006 and June 21, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683004 9106-0013-006F 170683005 9106-0013-005F 170683006 9106-0014-012F 170683007 9106-0014-033F 170683008 9106-0015-018F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Page 2 of 108 Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com 170683009 9106-0015-002F 170683010 9106-0001-132F Items of Note: At the request of Dale Randall on August 31, 2006, the samples listed above were relogged for various analyses.

A list of Sample ID's and requested tests follows.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Ten soil samples were analyzed for various analyses included in the FSSALL suite.Internal Chain of Custody: Custody was maintained for the samplc(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Page 3 of 108 Phone (843) 556-8171 o Fax (843) 766-1178 .www.gel.com 00 00 Analysis request -8/31/06 Done To be done Previous GEL ID CY sample location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr90 Pu241 Fe55 Ni63 Tc99 H3 C14 165614006 9106-0011-018F x x X X X X X X X X 166653003 9106-0012-005F x X X X X X X X X X 166653010 9106-0012-014F x X X X X X X X X X 167555007 9106-0013-005F x X X X X X X X X X 167555001 9106-0013-006F x X X X X X X X X X 167014026 9106-0014-012F x X X X X X X X X X 167014042 9106-0014-033F x X x x x x x x x x 167556010 9106-0015-002F x x X X X X X X X X 167556007 9106-0015-018F x x X X X X X X X X 1694 8 9 001 9106-0001-132F x X X X X X X X X X RELOGGED AS 170683 List of current GEL Certifications as of 06 September 2006 State Certification Alaska UST-062 !Arizona AZ0668 .Arkansas 88-0651 CLIA 42DO904046
  • California 01 151CA Colorado GenE ngLabs _____Connecticut PH-0169 Dept. of Navy NF-SC 413 .EPA WG,-1-- 5-Florida/NELAP

.E8-. ..Georgia E87156 (FIJNELAP) idaho N/A -.S.linoIts

---260002-9 S.Indiana C-SC-01 S.... Kansas E-10332.. .. .ntucky. 90129 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SCO-2 S ..........

-.a ...- -7. s,-_U 7T.. ..-New York150 North Carolina 233 North Carolina Drinking-W " -.. .... ......45709 North Dakota R-158 Oklahoma 9904_ _ Pennsylvania 68-485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont N/A Virginia .00151 Washington I C223 Page 5 of 108 Chain of Custody And Supporting Documentation Page 6 of 108 GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure U0 CD cc Chain of Custody Form No. 2006-00413 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

_Project Name: Haddam Neck Decommissioning Analyses Requested h .Contact Name & Phone: .yopni .....-..Jack McCarthy 860-267-2556 Ext. 3024 "" Analytical Lab (Name, City, State) .,@%;w.General Engineering Laboratories

< *" " 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones -z .-;L 4 Priority:

U 30 D. [ 14 D. Li 7 D. Container

.-Media Type &Type .- .'Sample Designation Date Time Code Code Code Comment, Preservation

--'ý s p r 9106-0011-011F 5/17/06 08:15 SE C BP x x Transferred from COC 2006-00356

, 9106-0011-012F 5/17/06 08:41 SE C BP X x Transferred from COC 2006-00356 9106-0011-012FS 5/17/06 08:41 SE C BP X X Transferred from COC 2006-00356.'

9106-0011-014F 5/17/06 09:34 SE C BP X x Transferred from COC 2006-00356 17 ., .9106-0011-015F 5/17/06 09:12 SE C BP X x Transferred from COC 2006-00356 9106-0011-018F 5/17/06 10:01 SE C BP X x Transferred from COC 2006-00356

.9106-0011-002F 5/15/06 14:33 SE C BP X x Transferred from COC 2006-00352 9106-0011-003F 5/15/06 14:58 SE C BP X Transferred from COC 2006-00352 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA [I Radwaste QA El Non QA Samples Shipped Via: l":i-te ..al~Fed Ex O~t1 O~ C ~ ~ ~ '(2\O(~ LIUPS LI Hand 1) Relinquished By DaterTime

2) Recei ate/Time Q ea JAI -4C tooE] the a 3) Relinquished By Date/Time
4) Received By Date/Time Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 7?tV ;3. -' 0
  • : SAMPLE RECEIPT & REVIEW FORM riOM use only Client: CO N ad rNlt ISDG/ARCOC/Work Order: /Date Received:

6 -,-i ' " PM(A) Review (5 -*oure am-conformrItam are resolved prior to siping): Received By: AL' ~j(Sample Receipt Criteria Z Z Comments/Qualirfers (Required for Non-Conforming Items)IShipping containers received intact Circle Applicable:

seals broken damaged contaiaer leaking container otler (describe) and sealed?Samples requiring cold Circle Coolan # ice bags blue ice dry ice I. oer ibe)2 preservation within (4 +1/- 2 C)?Record preservation m ethod. __ ___ 01_Chain of custody documents included with shipment?

J 4 Sample containers intact and Circle Applicable:

seals broken damaged container leakinl container otler (describe) sealed?Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

,, 8 Samples received within holding Ida's awn ess affected: time?Sample ID's on COC match ID's Sample ID's and conainers affected: on bottles?Date & time on COC match date Sample ID's affected: 10 & time on bottles? T117n6 , 0,47C$I WV-, /14/,/',P I ,-'/Number of containers received Sam*e D's affleited:

match number indicated on COC?COC form is properly signed in relinquished/received sections?

__14 Air Bill ,Tracking

  1. 's, & 2 ? e 7g Additional Comments PC PW ZRSO RAD Receipt If_7 *If > x2 area background is observed on samples identified as "aon-Suspected Hazard Information or a4 Zr § CA regulated/non-radioactive".

contact the Radiation Safety group for further Je Ee .investigation.

Aj Radiological Classification?

Maximum Counts Observed*:

or A" 6e, B [PCB Regulated?

X' Comments: IShipped as DOT Hazardous C Material?

If yes, contact Waste / Hazard Class Shipped: ,Manager or ESH Manager. UN#PM (or PMA) review of Hazard classi'ication:

Initials Date, i 0 I Page 8 of 108

  • Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received: fo 00 O'i 3v Work Order Number: L ' '-A I, Shipping Cdntainer ID:, 0 2721, 2Slf0 Chain of Custody*#

' -00YI/3 1. Custody Seals. oni shipping container intact? -Yes MA No [ I 2. Custody Seals dated and signed? Yes" [ ] No [. -3. chain-of-Custody record present? Yes [;q No [I]4. Cooler temperature 2 ,C 5. Vermiculite/packing materials is: Wet [ Dry []6. Number of samples in shipping container:

_7. Sample holding times exceeded?

Yes p.] No [].8. Samples have: "tape £._L hazard labels* A _custody seals __Sc_. appropriate sample labels 9. Samples are'9 -_in good condition -leaking-broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes [J No I(1.. Description of anomalies (include sample numbers): S.ample Custodian/Laboratory:Y Date: d i ot -0730.Telephoned to: On B _ __ _ _ _Page 9 of 108; Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major oq 00 00 Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power CompanyC No. 2006-00451 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

/M67_ _______'Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r Priority:

[] 30 D. M 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-002F 6/23/06 08:56 SE C BP X Transferred from COC 2006-00436 1 /9106-0012-003F 6/23/06 08:39 SE C BP x Transferred from CCC 2006-00436 9106-0012-004F 6/23/06 09:32 SE C BP X Transferred from COC 2006-00436 D 2-9106-0012-005F 6/23/06 09:56 SE C BP X Transferred from COC 2006-00436 Of&9106-0012-006F 6/23/06 13:07 SE C BP X Transferred from CDC 2006-00436 6D-9106-0012-010F 6/23/06 11:08 SE C BP x Transferred from CDC 2006-00436 6x-9106-0012-013F 6/23/06 110:56 SE C BP x Transferred from COC 2006-00436 9106-0012-013FS 6/23/06 10:56 SE C BP X Transferred from COC 2006-00436 NOTES: P0 #: 002332 MSR #: 06-o?49 SSWP# NA Z LTP QA E Radwaste QA [ Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: _ Deg.UPS C LI Hand Custody Sealed?Relinquished By DateTie 2) eived By / D- ... te/Time Custody Seal"IAEA C4 i 14O li Other Intact?3) Relinquished By Date/Time "4,)'ceive-d By"Z- Bil of Lain 4 aeT Y [3 N []Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time '3$ 4 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major 0 00 o0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00452 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

________Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <843 556 8171. Attn. Cheryl Jones r Priority:

[i 30 D. Z 14 D. []7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0012-007F 6/21/06 09:32 SE C BP x Transferred from COC # 2006-00433 9106-0012-008F 6/21/06 09:00 SE C BP X Transferred from COC # 2006-00433 aq 9106-0012-012F 6/21/06 09:19 SE C BP x Transferred from COC # 2006-00433 9106-0012-014F 6/21/06 10:05 SE C BP x Transferred from COC # 2006-00433 9106-0012-OIIF 6/21/06 09:51 SE C BP X ' _ Transferred from COC #2006-00433 oi 9106-0012-015F 6/21/06 14:24 SE C BP X Transferred from COC # 2006-00433 o jZ..9106-0012-009F 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 O 9106-0012-009FS 6/23/06 10:33 SE C BP X Transferred from COC # 2006-00436 al q 9106-0012-OOIF 6/23/06 09:18 SE C BP x Transferred from COC # 2006-00436 "5 NOTES: PO #: 002332 MSR #: 06-096? SSWP# NA Z LTP QA E] Radwaste QA Li Non QA Samples Shipped Via: Internal 0 Fed Ex Container El UPS Temp.: -Deg. C-- Hand Custody Sealed?YD NO I) Relinquished By Date/Time

2) Re ei d By Custody Seal~ 1.V-ohr4_

7 LitE ý Other Intact?..... Z100 7 ateftime CsoY SEalN 3) Relinquished By Date/Time

4) eRc d By _______ate__l-ime YE NO Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time -g .3? 7-9

~ENC/4,.~ Ii ~SAMPLE RECEIPT & REVIEW FORM*Po R~t- ' PM wse only Client; ~~~~~SDGARCOCIWork Order:.~ ~~/,45~i~

t Date Received:

JPMA) Rev~iew (~reneefortjmng jram arereslvd prior to sipung): Received By: Sample Receipt Criteria CominmentslQualifiers (Required for Non-Conforning em 1 Shipping containers received intact Circle Applicable:

seals broke, damaged cominer leaking comi and sealed? 7 Samples requiring cold Circl coalan' ikc bags blue icc dry ic oe""a describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents 3 included with shipment?4 Sample containers intact and Circle Applicable:

seals bmokem damag " leaking contain othr (descrbe)sealed?Samples requiring chemical Sample D's. conninets -ec7e ad PmH: preservation at proper pH?VOA vials free of headspace Sn* IDs and oi ed 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

S eSamples received within holding u affected: time? _________________________________

9 Sample ID's on COC match ID's SauWk ID's and com;ainers affected on bottles?I.. &Date & time on COC match date Samlple ID's affected: 10& time on bottles?__________________________

Number of containers received Sample ID's affected: match number indicated on C COC form is properly sig in relinquished/received sa tions? /Air Bill ,Tracki #'s, &Additional nts" if > x2 area background is observed on samtples idemiffied as *non-SuspectedHazardInformation regulated/non-radioacti"e', contact the Radiation Safety grow for harsher investigation.

A adiologica Si Clsiication?

Maxintum.

Counts Observed*:'

B B Regulated?

N."iomnts:

hpimd-as DOT Hazardous C Material?

If yes, contact Waste "AUAr Class Shipped: Manager or ESH Manager. UNI: PM (or PMA) review of Hazard classitication:

Initials Date: O U Page 12 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-OOl Figure 1. Sample Check-in List.Date/Time Received: SDG#: Work Orderubr W 7d4'3 t (L La5 /(.4 I O rer Nubr.Shipping Cchitainer ID; 7=1 "917_ ,C hi ofCustqdy*#k-

1. Custody Seals. ozi.shipping container intact?.... -Yes [- No ['" 2. CustodySeals dated and signed? ,cYe-s ' [3. Chain-of-Custody record present? Yes F ] .-**4. Cooler temperature

-5. .Vermiculite/packing materials is: Wet [/-6 t]6." Number of samples in shipping container

(,)... " (,2.7. /. ..7. Sample holding times exceeded?

Yes [ No II 10. Wcrc any anomalies identified in sample receipt? Yes [] No -(" 11. ..Descriptioa of anomalie (include sample numbers):.. ......Tclphnod to q-~- .K Page 13 of 108 Health Physics Procedure ii,, GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 0 00 Pc tbj Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00434 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories

.<2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Q Priority:

[1 30 D. Z 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code _ Comment, Preservation Lab Sample ID 9106-0013-006F 6/21/06 10:33 SE C BP X .....9106-0013-003F 6/21/06 10:51 SE C BP X X 9106-0013-002F 6/21/06 10:19 SE C BP x 9106-0013-002FS 6/21/06 10:19 SE C BP X 9106-0013-010F 6/21/06 13:56 SE C BP X9106-0013-O1OFS 6/21/06 13:56 SE C BP X , 9106-0013-005F 6/21/06 14:40 SE C BP X --.9106-0013-OIIF 6/21/06 13:35 SE C BP x NOTES: PO #: 002332 MSR #: 06-i'3YSSWP#

NA [ LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container g Fed Ex Temp.: *jj Deg, C El UPS El Hand Custody Seale?1) Relinquished By Date/Time

2) Re eived Date/Time Custody Seal Intact?iH Me ~ 114-~ // ff' E Other 3) Relinquished By Date/Time
4) Received Ay D Date/Time BillofLading#

_Y GE] N O Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time

-qflj -y" /1 -2 Z g'4 Health Physics Procedure/67555/..GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-.GGGR-R5 1 04-003-Attachment B-CY-00 I Major f if --Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00444 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only 0o Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories

  • .2040 Savage Road, Charleston SC. 29407 .eý843 556 8171. Attn. Cheryl Jones Priority:

El 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code,-.., Comment Preservation Lab Sample ID l9 9106-0013-007F 6-27-06 10:58 SE C BP X Jo 9106-0013-014F 6-27-06 09:22 SE C BP X j( 9106-0013-015F 6-26-06 15:06 SE C BP x Transferred from COG 2006-00438 , 9106-0013-001F 6-23-06 13:32 SE C BP X Transferred from COC 2006-00437 jf, 9106-0013-004F 6-23-06 13:51 SE C BP X TransferredfromCOC2006-00437" 9106-0013-009F 6-23-06 14:08 SE C BP X Transferred from COC 2006-00437 9106-0013-013F 6-23-06 14:38 SE C BP X Transferred from COC 2006-00437 9106-0013-008F 6-26-06 11:11 SE C BP X Transferred from COC 2006-00438 9106-0013-012F 6-26-06 12:35 SE C BP x Transferred from COC 2006-00438 NOTES: PO #: 002332 MSR #: 06-.'V3i SSWP# NA SLTP QA[] Radwaste QA El Non QA 1) Relinquished By Date/Tine

2) Reiv By Date/Time 3) Relinquished By Date/Time
4) Receive'd By 0 Date/Time Samples Shipped Via: Z Fed Ex 0] uPs[J Hand El Other Bill of Lading #-' to 5-7ti Izoqr Internal Container Temp.: -il Deg. C Custody Sealed?YE) Ne Custody Seal Intact?YE] NO 6 SAMPLE RECEIPT & REVIEW FORM F2 -.,M ... .OnlyI (~cunt: 1SDIGARCOCIWark Orael": ~-19 I Date Received:

"'A k\,k 0)a ~PM(A) Review 7 aoC fl r~~~arsovd prifr to signing)L7 Receiveu _Y: _ __4/Sample Receipt Criteria (Requird for Non-Conforming Items)Sample Receipt Criteria eq 1 I Shipping containers received intact Chic Apikable:

seals broken daniqed --container oil= (describe) 1 and sealed? Jm, -amples requiring cold cirdc coolant ice bags bl. ice d Qc other describe)2 preservation within (4 +/ 2 C)? .Record preservation method.- ' Cd\. -Chain of custody documents

/included with shipment?

-Sample containers intact and Cice Applicable:

seals boke* daav leaking coamia other (decibe)sealed? ___Samples requiring chemical ma. cMauaC -a a o p: preservation at proper pH? _VOA vials free of headspace Sa ID's wd cominers atied;(defined as < 6mm bubble)? ,_, Are Encore containers present?7 (if yes, immediately deliver to VOA laboratory)

__._.. .._,_, 8 Samples received within holding /s-,nd ,.i 11ce:--lime?Sample ID's on COC match ID's sa/-e __san_ _ cmi_ _ affect:-on bottles? Date & time on COC match date SaCe ID 's affecied:& time on bottles?Number of containers received Saole ID's affected: match number indicated on COC?COC form is properly signed in relinquished/received sections?

,__, 14 Air Bill ,Tracking

  1. 's, &Additional Comments TU ~ R!SO RADReceipt#

Suspected Hazard Information f E : background is observed o0 samples idenod as -noa-~. uauatdio-radioactive%

ontact the itadiation fe group fo h investigation.

A Radiological Classification?

Maxi.niu Coums Observed, _________00 i D Regulated?

IShipped as [XJIiHazardous C Material?

If yes, contact Waste (Hz Clas Shipped:lManager or ESH Manager. UIN: MIA! ic. Of H.zard classitication:

Initials SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM 7r,0~0N O1 f2lL-rn \4cA C-1, 9 Do~oo-c----x CID ace -ctoLm-O~u-q --xbq Page 17 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services .cY-ISC-Sow-OwI Figure 1. Sample Check-in List.Date/Time

.X SDG#: *o ..Work Order Number: Shipping Cdntainer 11D:Ci!2ý Cf'kS14 Chain of Custody # ~ C(A 1. Custody Seals on shipping container intact?.. -Yes[ ]NoJ-2. Custody Seals dated and signed? Yes'[1 No [ ] s I Chain-of-Custody record present? Ye" No [].4. Cooler temperature

'_.-LQ,- P S\ k - 5. Vermiculite/packing materials is: Wet [ ].Dry F) tC r 6' .Number of samples in shipping container: (iCTh. ".7. Sample holding times exceeded?

Yes No.8. Samples have:~It----..hazard labels.4 custody seals " ..Zlappropriate sample labels 9. Samples arei*..i good condition c jeaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes[ ] No '.11. *Description of anomalies (include sample numbers):.CustodiantLaboratoxy4'<a" .- t .Telephonedto:

On By ae 18 -f. -08 Page 18 6H:.0.8 .. .. '-"

Health Physics Procedure 16-,poi4-1 GPP-GGGR-R5104-003 -Attachment B-CY-001 Major CD 0 00 Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00456 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested

..seO Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) -: General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 C)843 556 8171. Attn. Cheryl Jones -Priority:

E30 D. 14 D. 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lp I " 9106-0014-021F 6/15/06 10:50 SE C BP X Transferred from COC 2006-00407 9106-0014-030F 6/1 5/06 11:20 SE C BP X Transferred from COC 2006-00407

.9106-0014-032F 6/15/06 09:31 SE C BP X Transferred from COC 2006-00407 9106-0014-043F 6/16/06 08:45 SE C BP X Transferred from COC 2006-00409

". ., 9106-0014-OIOF 6/12/06 14:23 SE C BP x Transferred from COC 2006-00391

-9106-0014-016F 6/12/06 14:51 SE C BP X Transferred from COC 2006-00391 9106-0014-022F 6/12/06 15:12 SE C BP X Transferred from COC 2006-00391 9106-0014-013F 6/13/06 15:06 SE C BP X Transferred from COC 2006-00394 9106-0014-024F 6/07/06 09:58 SE C BP X Transferred from COC 2006-00385 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA El Radwaste QA E] Non QA Samples Shipped Via: I C .ifer C[]Fed Ex !T(El UPS El Hand ?ts~y ei4 1) Relinquised By Dateiime 2) c ved By Date/Time O C, Seatttc?3) Relinquished By Date/Time 4)A & ved_ By _ _te,_ _ __ e, ,- W.Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time

?,M./ 4 ..OV Health Physics Procedure I( -TrN-IA GPP-GGGR-R5104-003-Attachment B-CY-001 Major ,, I ,,,, , '--, b I .. .. .of Custody Form CDNo. 2006-00457 kConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: 1-laddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories

-2040 Savage Road. Charleston SC. 29407 0 843 556 81.71. Attn. Cheryl Jones Crn Priority:

E] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 6(0 9106-0014-025F 6/7/06 10:18 SE C BP X Transferred from COC 2006-00387 fl( 9106-0014-031F 6/7/06 10:44 SE C BP X Transferred from COC 2006-00387 9106-0014-017F 6/9/06 07:39 SE C BP X Transferred from COC 2006-00387 013 9106-0014-023F 6/9/06 08:23 SE C BP X Transferred from COC 2006-00387 614 9106-0014-035F 6/9/06 09:03 SE C BP X Transferred from COC 2006-00387

9106-0014-038F 6/9/06 10
59 SE C BP X Transferred from COC 2006-00397 6 9106-0014-039F 6/9/06 09:28 SE C BP X Transferred from COC 2006-00387 9106-0014-042F 6/9/06 09:53 SE C BP x Transferred from COC 2006-00387 0 '9106-0014-034F 6/9/06 10:11 SE C BP X ,,,_ Transferred from COC 2006-00387 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [: Radwaste QA El Non QA Samples Shipped Via: Internal Container 0g Fed Ex Temp.: __ Deg. C C' CL]C UPS Hand Custody Sealed?1) Relinquished By Date/Time
2) Re Datime Custody Seal Intact?47ZE '-1.Og//t o Other 3) Relinquished By Date/Time
4) R ived By --"ae/_ime BillofLading YO NE Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time /. 4 J'- 3?Yc/

Health Physics Procedure 1 (a~A4 '/GPP-GGGR-R5104-003 -Attachment B-CY-001 Maj or* -I-v '. [Chain of Custody Form CD No. 2006-00458 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

[] 30 D. Z 14 D.EI 7 D. Container Sample Size- ,! 'Media Type &Type Sample Designation Date Time Code Code Code o e-P ra-a-me) 9106-0014-029F 6/09/06 08:42 SE C BP X Transferred from COC 2006-00387 9106-0014-009F 6/13/06 08:44 SE C BP X Transferre-from COC2006-00392-)ao 9106-0014-028F 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-028FS 6/13/06 08:08 SE C BP X Transferred from COC 2006-00392 9106-0014-036F 6/13/06 09:38 SE C BP XTransferred from COC 2006-00392 9106-0014-037F 6/13/06 09:12 SE C BP X Transferred from COC 2006-00392 9106-0014-040F 6/13/06 10:42 SE C BP X Transferred from COC 2006-00392

,/9106-0014-041F 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 9106-0014-041FS 6/13/06 10:13 SE C BP X Transferred from COC 2006-00392 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: Internal Container" Fed Ex Temp.: _ Deg. C[1 ups El Hand Custody Sealed?YC N ]1) Relinquished By Date/T' e 2) Reegived By Date/Time Custody Seal Intact?3) Relinquished By Date/Tirne

4) Xkeived By fate/ime BillofLadig YE NO Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 7c: 4lqyV? 4ol4 Health Physics Procedure

/7 GPP-GGGR-R5 104-003 -Attachment B-CY-001 Major CD Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-0045 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556.

o Project Name: H-addam Neck Decommissioning Analyses Requested Contact Name & ?hone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) T .-Li General Engineering Laboratories

.2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r, m ." Priority:

[130 ID. 14 D., 7 D. Container

~~ >:Sample Size-Media Type &Type Sample Designation Date -Time Code Code Code Comment, Preservation , -9106-0014-012F 6/06/06 12:47 SE C BP X -Transferred om COC 2006-00384

  • '..-. .:-,... .7 D 9106-0014-018F 6/06/06 14:45 SE C BP X Transferred from COC 2006-00384 M, 9106-0014-019F 6/06/06 14:25 SE C BP X Transferred from COC 2006-00384 "d 9106-0014-001F 6/09/06 13:37 SE C BP X Transferred from COC 2006-00392 84 ., ..9106-0014-002F 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 .f .' 9106-0014-002FS 6/09/06 14:40 SE C BP X Transferred from COC 2006-00392 9106-0014-005F 6/09/06 14:12 SE C BP X Transferred from COC 2006-00392

.9106-0014-006F 6/09/06 13:07 SE C BP X Transferred from COC 2006-00392 " ,J ,.9106-0014-OIIF 6/09/06 12:44 SE C BP X Transferred from COC 2006-00392

' .NOTES: P0 #: 002332 MSR 4: 06- SSWP#NA U LTP QA El Radwaste QA El Non QA Samples Shipped Via: 4d 1) Relinquished By Date/Time

2) Rec& ed By at9(Tire P" 3) Relinquished By Date/Time
4) Lved By " il oF L....ng)elnqisedByDae/im6 RemBill of Lading #'5) Relinquished By Date/Time
6) Received By Date/Time 3q- q':

Health Physics Procedure

/ --- j4. GPP-GG GR-R5 104-003 -Attachment 13-UY -Ut1 Major Chain of Custody Form No. 2006-0046 CConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

., , __.....__._,._..,,,__...,._,___

....... _Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: its:, Jack McCarthy 860-267-2556 Ext. 3924 Jack: Analytical Lab (Namne, City, State)General Engineering Laboratories

-. .. -; ..2040 Savage Road. Charleston SC. 29407 V2 , 843 556 8171. Attn. Cheryl Jones Priority:

E] 30D. Z 14 D. C] 7 D. Container Sample size-Media Type &Type Preservation

  • Sample Designation Date Time Code Code Code ..-.TneComment, Preservation 200-039'9106-0014-003F 6/14/06 08:46 SE C BP X Transferred from COC 2006-00396 4, c 9106-0014-007F 6/14/06 09:13 SE C BP X Transferred from COC 2006-00396 9106-0014-008F 6/14/06 07:34 SE C BP X Transferred from COC 2006-00396

,, ""a 9106-0014-008FS 6/14/06 07:34 SE C BP ] X Transferred from COC 2006-00396_Y

-"._nt 01 nQ -_n1 A -0 1 AT nd A InlT a n .AP X Transferred from COC 2006-00396 I. .Other Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major CD t0.Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 I Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

[] 3013. E 14 D. [] 7 D.Comment, Preservation , Jnple¢ I , D Transferred from COC 2006-00396 Transferred from COC 2006-00396 Transferred from COC 2006-00396 , : ,: Date Samples Shipped Via: Z Fed Ex El uPs M Hand-F- Other Bill of Lading #7;t 4qfo 391-i 1 e1 SAPLERECEIPT

& REVIEW FORM 0 1_5 Client: 12L DG/ARCOC/Work Order: Date Rec ed: PM(A) Review (ensure non-coaforon are resoved prior to signing): Received By: ,3D(Sample Receipt Criteria P [ Z Comments/Qualifiers (R ui for Non-Confrming it I Shipping containers received intact I Circle A"'lic"ble:

Mh broken danad cowIner leaking co"amne Samples requiring cold Circle Coolant # ice bags blue ice -dry'ic none oilir describe)2 preservation within (4 +/- 2 C)?Record preservation method.3 Chain of custody documents included with shipment?[ Sample containers intact and Circle Aplica*ie:

sealt broken damag eu Conan sealed? !SaMples requiring chemical ample IDs. Continers a b p reservation at proer H?6 VOA vials free of headspace Sample ID's and c af ..fected: (defined as < 6amm bubble)?Are Encore containers present? / " d(if Yes. immediately deliver to VOA laboratory P Samples received wicthin holding ad Ini , af. e ae: Pime? 2 f1 Sample ID's on COC match ID's SmlIDs adcumirny arlecte: on bottles?& time -on bottles?11 flumber of cont~ainer's ID' Saffecled:

match number idctd CC IC.oc flo mgedi 14Ar Bill acking #Is,&Addi*a Comments S S RAD Receiptx Suspected Hazard Information t-*L > x2 area background is obsenred oý smnples idenifeda 4, ruatdo-radioactive*, conwtath p' RaiaonSfy.nvestigation, r. o ute U a ed li~x rn im C ou i s Ob er ed, " lp asa uO Io m n s H " CMaterial?

If yes, contact WasteHardCssSip:

Manager or ES1H Manager. UN#: I PM ( t-or FM) review of Hazard classification Page 25 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services ,CY-ISC-SOW-001 Figure 1. Sample Checqk-in List.Date/Time Received:

-0 P3/{J " SDG#: AA& L c%(19 -OqSIZ Work Order Number: 1 (63". L(Shipping C0itainer ID,7 "Z Chain of'Custody

  1. " 6o1--1. Custody Seals o0 shipping container intact? Yes t [ ]2. Custody Seals dated and signed? Yes, ](lo [ I 3. Chain-of-Custody record present? Yes l No [1 4. Cooler temperature

".-5. Vermiculite/packing materials is: Wet ry t ]6: Number of samples in shipping container:

"_"_ " 7. Sample holding times exceeded?

Yes [T-j]"o [1.8. Samples have.' 'tape .hazard labels_ 'custody seals -appropriate sample labels 9. Samples are good condition -leaking broken "have air bubbles 10. Were any anomalies identified in sample receipt? Yes No.Descripio of anomalies (include sample numbers): Sample Custodiaw/Laboratory:

Telephoned to: :O. * -" .A__uB.: r., ". ..Page 26 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O0i Figure 1. Sample.Check-in List.DatelTime Received:

7 0 9.SDG#- ~,~'0 o 3 Work Order Number0~9~I9?-39,76 Shipping C'.ntainer IDý 4 chain of custody'#

26 L).. !. Custody Seals odsbipping container intact?.._

[t 2. Custody Seals dated and signed? Yes 'rNo [ ].3. Chain-of-Custo'.y record present? Yes [T1No [1 4. Cooler temperature

2 ;6'S. Vermiculite/packing materials is: Wet [--Dry t, ]6 'Number of samples in shipping containere.

"" 7. Sample holding times exceeded?

yes H 4 o.8. Samplea have-.S-hazard labelst~zody seals appropriate sample labels 9. Samples are" I.n good condition -lealking-_broke ..."have air bubbles 10. .Were any anomalies identified in Sraple receipt' Yes[J opj-'1. .Description of anomaiCs. (include sample mbers):___

Tclc-plzouca to:_____________

Page 27 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services Figure 1. SamplCheck-4n List.DatefTime Received: SDG #i. .,6ý1 -0,, 9 8 Work Order Number -/L41.g Shipping Cdntainer ID: Yý5L4.5&7.

Chain of Custodyk#I. Custody Seals oni shipping container intact?..2. Custody Seals dated and signed?3. Chain-of-Custody record present?.4. Coolertemperature

5. Vermiculite/packing materials is: 6. Number ofsamples in shipping container.
7. Sample holding times exceeded?-yes4o[Yes kT , I I. -Yes V 4ýo I I Wet P-j15-r t (es [No []L.~5U~U ~onflfll~eaking

-~have air bubbles 10. -a omaliesidentified in sample receipt? Yes'[ .No 1 1". .Description of anomalies (include sample numbers): Sample Custodiajaab try.'T-cp*on t _-_-_-_._O___By to*Page 28 of 108 Connecticut Yankee ISC-SOW-O01 Statement of Work for Analyctical Lab Services Figure 1. Sample Check-in List.Date/Time Received: SDG#:tQ#009 Work Order Number: (- 7 0/t'Shipping Cdhtainer LA59 Chain of Custody 1. Custody Seals ori shipping container intact?. *Yes [Td o I .2. Custody Seals dated and signed? Yes ,i'No [ I _3. chain-of-Custo'dy record present? Yes ri No 1)4. Cooler temperature

5. ..Vermiculite/packing materials is: Wet [,Kry I',]6C Number of samples in shipping container:
7. Sample holding times exceeded?

Yes L-rNo I 8. Samples have:*.- Jhaazard labels seals .appropriate sample labels 9. Samples are-:in good condition leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ N NO r S11.. ,Description of anomalies (include sample numbers): Sample.

Dt'Tcalphoncd to: ,O By " Page 29 of 108 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-O0O Figure 1. Sample Check-in List.Date/Time Received:

_, "___SDG#: s 5 O& -a9;W ork Order Number. __ __ __ __"__-_"__---_

__ __ ....Shipping CdotaineriD:, 3_.'-'_ ChainDofCustody_#.M,1)6,._

_0_ QA_1. Custody Seals osishipping container intact? -Yes ;4-go [I 2. Custody Seals dated and signed? Yes',-io [1.3. Chain-of-Custody record present? Yes L'1ro L ]4. Cooler temperature , L- 3 5. Vermiculite/packing materials is: Wet ,-gry ] .6. "Numberofsamples in shipping container;.

7. Sample.holding times exceeded?

Yes 8. Samples have:% " "-hazard labels"" oy seals 8appropriate sample labels*9. Samples are.-'Z good condtion -leaking* ..broken '..' ".. jhave air bubbles 10. Were any anoinaliesidentified in sample receipt? Yes (1 No [I.-11.. : .Description of anomnalies(include sample nurs__. _ *Sample Custodiazvýabory:-----------

Tclephoned to_;_ Dy -Page 30of 108 Health Physics ProcedUI?'-,',,,;('-/_

GPP-OGGR-R5104-003 -Attachment B-CY-00 I Major Health Physics ProceduJ?.~~.~y/

GPP-GGGR-R5 1 04-003-Attachment B-CY-00 1 Major ILf# I ~~*Uf I -Chain of Custody Form No. 2006-00443 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning "Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Z- n (Z z Priority:

[1- 30 D. Z 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 1 9106-0015-022F 6-27-06 16:24 SE C BP X X 9106-0015-023F 6-27-06 16:03 SE C BP X X 9106-0015-024F 6-27-06 15:42 SE C BP X X 9106-0015-026F 6-27-06 14:58 SE C BP X _ X 9106-0015-027F 6-27-06 15:17 SE C BP X x: 9106-0015-028F 6-27-06 14:31 SE C BP X X 1 9106-0015-018F 6-27-06 17:18 SE C BP X X g 9106-0015-025F 6-27-06 16:43 SE C BP X x 9106-0015-021F 6-27-06 17:01 SE C BP X NOTES: PO #: 002332 MSR #: 06-105J ; SSWP# NA 0 LTP QA[] Radwaste QA[D Non QA 1) Relinquished By Date/Time

2) R ived Date/Time 3) Relinquished By Date/Time
4) Received BY J Date/Time Samples Shipped Via: E Fed Ex I UPS Ml Hand El Other Bill of Lading #?-qO 1 5- -/I/Jot Internal Container Temp.: 1I Deg. C Custody Sealed?YO N7" Custody Seal Intact?YO NO Health Physics Procedure/ bi -7, , /.GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major&W', U L(,':- I -' '~~~~~Chain of Custody Form n.20-04 Connecticut Yankee Atomic Power Company No. 2006-00448 362 Injun Hollow Road, East Hampton, CT 06424 o860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested MR. .Contact Name & Phone: -"-" : Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State) p General Engineering Laboratories 2040 Savage Road. Charleston SC, 29407 0 843 556 8171. Attn. Cheryl Jones co COO Priority:

E] 30 D. Z 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designatioa Date Time Code Code Code ... .Comment, Preservation ... e .9106-0015-011F 6-28-06 14:39 SE C BP X X _,_______-___.,_..___..._

9106-0015-012F 6-28-06 10:58 SE C BP X X __,: __ ___ __..........._

_ .......9106-0015-013F 6-28-06 10:04 SE C BP X X _____..____.___.;.._______

". ..... .. .....pf 9106-0015-014F 6-28-06 09:05 SE C BP X X 31 9106-0015-015F 6-28-06 08:25 SE C BP X i.12 9106-0015-016F 6-28-06 08:46 SE C BP X X 77.77..9106-0015-017F 6-28-06 09:47 SE C BP X X 9106-0015-019F 6-28-06 09:25 SE C BP X X 6 __:Z __'"__'_..

9106-0015-020F 6-28-06 07:59 SE C BP X X ":_______"_

_-___"-_,__."-

NOTES: PO #: 002332 MSR #: 06- 2o 3 7- S SWP# NA SLTP QA E] Radwaste QA[: Non QA 1) Relinquished By Date/3ime 2)ycivdcB' Date/Time 3) Relinquished By Date/Time

4) Received By Q Date/Time Samples Shipped Via: Z Fed Ex E1 UPS[] Hand E] Other Bill of Lading #q7//0 5-.- (tl 2 Y ,'YE NE Health Physics Procedure,/GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00447 362 Injun Hollow Road, East Hampton, CT 06424 0860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: 'omm S-*.: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories

% --2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:E]

30 D. N 14 D. L1 7 D. Container Sample Size-Media Type &Type Sample Desigation Date Time Code Code Code .Comment, Preservation Labp- ei-p 9106-0015-OOIF 6-28-06 13:36 SE C BP X X o 9106-0015-002F 6-28-06 14:15 SE C BP X X -. .11 9106-0015-003F 6-28-06 13:15 SE C BP X X 0 9106-0015-004F 6-28-06 12:54 SE C BP X 2 9106-0015-005F 6-28-06 15:47 SE C BP X X : .:- .f 9106-0015-006F 6-28-06 16:10 SE C BP X X 9106-0015-007F 6-28-06 11:33 SE C BP X X .9106-0015-OOF 6-28-06 11:10 SE C BP X X ta 9106-0015-009F 6-28-06 10:25 SE C BP X X F!9106-0015-OIOF 6-28-06 15:17 SE C BP X X -" ."-NOTES: PO #: 002332 MSR#: 06-/J357 SSWP#NA SLTP QA[I Radwaste QA El Non QA I) Relinquished By Date/Time Date/Time 3) Relinuihd By-Date/Tm 4)" 2eceiedht-Date/Time 3) Relinquished By Date/Time

4) Received by DJ* Iate/Time-Samples Shipped Via: ER Fed Ex E]ups LI Hand LI Other Bill of Lading #-4 Wo y H/ I (2 a 0&~t~dy S~YIntact?

-YtJ N0 Health Physics Procedure)/-~Ac/~GPP-GGGR-R5 104-003-Attachment B-CY-001 Major I (~' I '~ ~"W I C Chain of Custody Form roNo. 2006-00468 CConnecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 0 ~860-267-2556-

-Project Name: Haddam Neck Decommissioning Analyses Requested

..-.. ,.... ..oo Contact Name & Phone: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 .: .843 556 8171. Attn. Cheryl Jones ..Priority:j3 0D.~ 14 D.EFI7 D. Container Sampl Size-Media Type &Type Sample Desipation Date Time Code Code Code Preservation i 9106-0015-005FS 6-28-06 15:47 SE C BP X X 9106-0015-012FS 6-28-06 10:58 SE C BP X -x -l l 9106-0015-018FS 27-06 17:18 SE C BP X X NOTES: PO #: 002332 MSR#: 06-1(93f SSWP#NA Z LTP QA 0 Radwaste QA E] Non QA 1) Relinquishei By Date/T*ne

2) ceivdB Date/Time 3) Relinquished By Date/time
4) Receive&By "3 Date/Time Samples Shipped Via: Z Fed Ex ElUPS[] Hand El Other Bill of Lading #'4110 S- 1 2f'TC Custody SeCA dustdy~el~nact?,

-- SAMPLE RECEIPT & REVIENh FORM I C77 K tC~/ i~1IC AI(n 7~4~,/ Pi _ , I r Client: C'X.n, .-r or mate Received:

ý'\ ow\JMA elw(nu~ ~ UIDtI~ uhdplft pig hReeceived By: --I# V Sample Receipt Criteria CommentsQualiners (Requir i for Non-Conforming Items)Shipping containers received intact / Circle seals broken dmagne nco la lo=

oer (dmie)and sealed? r i eo es Samples requiring cold Circlf C t ebas biw ! dry i o descri)2 preservation within (4 +/: 2 C)? / -Record preservation method. 4 __.___,__.

__________.__, Chain of custody documents included with shipment?

._Sample containers intact and / irie Applicable:

suebl boen dandcomalner lakingeomaaner ohier(describe) sealed? -I Samples requiring chemical / Samle IDas containers affecied and observed P preservation at proper pH? ,,__VOA vials free of headspace siip I'- a ffeted: (defined as < 6rm bubble)_Arc Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

,,__Samples received within holding Id's and mme affected: time?--_ _ _ __ _ __Sample 1Ds on COC match ID's Sam&le ID's and contauines affehed: on bottles? /of__Date & time on COC match date / S1an*k If's affected:& time on bottles?1_i Number of containers received /Samtc ID's affected: match number indicated on COC?COC form is properly signed in relinquished/received sections?

_4 Air Bill ,Tracking

  1. 's, &Additional Comments , Z I RSO RAD ReceiptI-. *If > x2 area background Is observed Oo samples identifieda "anon-Suspected Hazard Information o P go regulated/non-radioactive'.

contact the J"adiation Safety group far further 1Z_ __ investigation.

A Radiological Classification?

I" MaxNimum Courns Observed*-" C.12 !.PCB Regulated?

I i mes: I.hipped as DOT Hazardous Material?

If yes, contact Waste ( Hazard Class Shipped: Manager or ESH Manager.':

PM (or PMA) review of Hazard classitication:

Initials "- Date: qf-z"- oz"t" i Page 35 of 108 Connecticut Yankee CY.1SC-SOW-001 Statement of Work for Analytical Lab Services .Figure 1. Sample Checqk-in List DatefTime Received:

\ -SDG#: t~~~o(# OS M 2 1 3 ~ o i Work Order Number-.__

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _Shipping Cdntainer ID-S CCN-A- --i s\ -.="C Chain of Custody# x Ct'-_*.1. Custody Seals oni shipping container intact?., -Yes ( ] No p" 2. Custody Seals dated and signed? Yes [) No o r 3. Chain-of-Custody record present? Yesyf NO,]4. Cooler temperature

.°-" -C. .' .*5. Vermiculite/packing materials is: Wet []Dry , 6." Number of samples in shipping container: (iQ'r-- CN " 7. Sample holding times exceeded?

Yes [ No.8., Samples have: , tape .hazard labels..custody Seals ..eIappropriate sample labels 9. Samples are:, good condition leaking"broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] 11. Description of anomalies,(include sample numbers):.ample Custod.ian/L-ab. " .oratomnx.

Telephoned to: On_______71b_

flaoac 'i Page 36 of 108 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM-~ c l4 r qqx~5n\ v18 CUP- W-6L-W 13ockc -0oot,-to I~ L06~p WýQLI-t-OWL44 z1-QL (~~1~d I Page 37 of 108 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 00 utý00 00 Chain of Custody Form No. 2006-00496 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested

.. .. : .Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones V" Priority:

30D. .14 D. 0 7 D. N..D. ....Container Sample Size- o Lab I Sample Designation Date Time Media Type &Type Comment, Preservation S"i,'": Code Code Code 9106-0001-132F SE C BP X _ _ _ _ ____ ..,_.____...

9106-0001-112F SE C BP x 9106-0001-132A SE C BP x _,_......._________

.9106-0001-132B SE C BP X 9106-0001-132C SE C BP X _____ __________.....___....

9106-0001-132D SE C BP x _ _ _ _ _ ,__:,-___,<"_

9106-0001-112A

____ SE C BP X- -_ _______ ______9106-0001-112B SE C BP X -9106-0001-112C SE C BP X ____ __:__._______

NOTES: PO #: 002332 MSR #:06- #70 SSWP# NA U LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Iht onfaiier[ Fed Ex -en)p D:g, D] UPS ;"; " .-[] Hand :ustody Seled 9 1) Relinquished By Date/Time

2) Received By D te/Time :: adySea ,, i:-..; -:-: :.. /..-....-:.Other
3) Relinquished By Date/Time
4) Received By Date/Time V_--.___ W__,_Bill of Lading #-5) Relinquished By Date/Time
6) Received By Date/Time 79;/ p]-3o .1 " "'
  • Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major CD 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested

-"'.Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones n.Priority:

30 D. 14 D. 7 D. 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation

Lf,;pId 1151 Code Code Code 9106-0001-I 12D SE C BP X -. .NOTES: PO 9: 002332 MSR ~:06- irV3 SSWP# NA U LP QA ElRadwaste QA F1 Non QA Samples Shipped Via.:o~i~SFed Ex. eg ElUPS E] Hand ... .ll " 'l 1) Relinquished By Date~fime
2) Received By Date/Time CadySeal ii 9 irt 9~'( ~ ~ / c/ /5 CLL~~ ~ ltist ~ED Otherti 3) Relinquished By Date/Time
4) Received By Date/Time

_________Y)

N Bill of Lading 5) Relinquished By Date/Time

6) Received By Date/Time

~ ~ y~_ _ _ _ _ _ _ _ _ ' .a .,, : :

  • Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 I Figure 1. Sample Check-in List Dateffime Received:

g /1/-704 0 ~ /-~SDG#: /A(-'T 113&Work Order Number: /6' 9 ' I"/Shipping Cdntainer ID: ?9Z/ 7 6130 -MgrL Chain of Custody*# (o 51-i &'1. Custody Seals orf shipping container intact? Yes [ ] No [fk4-2. Custody Seals dated and signed? jYe [ ] No [I.3. Chain-of-Custody record present? Yes -No [I 4. Cooler temperature_,_

_ _ _ __"_ _ _ _ _.5. Vermiculite/packing materials is: Wet [ Dry ," 6: Numberofsamples in shipping container:V -i0 4-.v 7. Sample holding times exceeded?

Yes []No[].8.. Samples have:*------- __.__a.azard labels seals -appropriate Sample labels 9. Samples are:*g good condition

._ leaking[ : :broken "" have air bubbles 10. Were any anomalies identified in sample receipt? " Yes[] No []" 1 .:.Description of anomalies.(include sample numbers):

4/,047 e -Sample Custodian'Laboratory:

." r % Date //d 4 Telephoned to:_ _ _ _ _ _ " y .Page 40 of 108 SAMPLE RECEIPT & REVIEW FORM/1 ~CONTINUATION FORM 0-jcnn.cc-, c-LA- nnnr<gt Pq-tmi c. iP ( Ca r-n Q_-, 91-o- 32 ?y-J-t-eo 4_ r.-jr;a-2_

L- , -iq:f-gl1,- EI .I. q-A -, O cif 9l -- 1 o'z 5(v: s qlh I DU II , b-1-o 9:Z 14-O~ 0- Iq Se, CiIo -- ll Di -145-o 1 O9'-Z?-, ) Coc.:W- "LCo oq Ci 1ýq I -- 0 0%S Iloun-- oo7,gSuo,.

b- ,-01p 0-'n,5 91OU --003:ýU , 1-D-p t 910(p- 004SI Page 41 of 108 RADIOLOGICAL ANALYSIS Page 42 of 108 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170683 Method/Analysis Information Product: AIphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565213 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 170683010 9106-0001-132F 1201175602 Method Blank (MB)1201175603 170683004(9106-0013-006F)

Sample Duplicate (DUP)1201175604 170683004(9106-0013-006F)

Matrix Spike (MS)1201175605 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683004 (9106-0013-006F).

QC Information All of the QC samples met the required acceptance limits.Page 43 of 108 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments The sample and the duplicate, 1201175603 (9106-0013-006F) and 170683004 (9106-0013-006F), did not meet the relative percent difference requirement, however they do meet the relative error ratio requirement withvalue of 2.11.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 567705 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201181287 Method Blank (MB)1201181288 170683003(9106-0012-014F)

Sample Duplicate (DUP)1201181289 170683003(9106-0012-014F)

Matrix Spike (MS)1201181290 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Page 44 of 108 Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683003 (9106-0012-014F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Batch reprepped due to Thorium interference.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments The sample and the duplicate, 1201181288 (9106-0012-014F) and 170683003 (9106-0012-014F), did not meet the Am-241 relative percent difference requirement, however they do meet the relative error ratio requirement with a value of 0.512.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Page 45 of 108 Analytical Method: DOE EML HASL-300, Pu- I I -RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565210 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201175591 Method Blank (MB)1201175592 170683001(9106-0011-018F)

Sample Duplicate (DUP)1201175593 170683001(9106-0011-018F)

Matrix Spike (MS)1201175594 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683001 (9106-0011-018F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 46 of 108 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565214 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 170683010 9106-0001-132F 1201175606 Method Blank (MB)1201175607 170683004(9106-0013-006F)

Sample Duplicate (DUP)1201175608 170683004(9106-0013-006F)

Matrix Spike (MS)1201175609 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 I1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 47 of 108 Oualitv Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683004 (9106-0013-006F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I I-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565216 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 170683010 9106-0001-132F 1201175614 Method Blank (MB)1201175615 170683004(9106-0013-006F)

Sample Duplicate (DUP)Page 48 of 108 1201175616 170683004(9106-0013-006F)

Matrix Spike (MS)1201175617 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683004 (9106-0013-006F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201175614 (MB), 1201175615 (9106-0013-006F), 170683004 (9106-0013-006F), 170683005 (9106-0013-005F), 170683008 (9106-0015-018F), 170683009 (9106-0015-002F) and 170683010 (9106-000l-132F) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Qualifier information Manual qualifiers were not required.Method/Analysis Information Page 49 of 108 Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I I-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 567883 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201181751 Method Blank (MB)1201181752 170683001(9106-0011-018F)

Sample Duplicate (DUP)1201181753 170683001(9106-0011-018F)

Matrix Spike (MS)1201181754 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683001 (9106-0011-018F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Page 50 of 108 Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis The batch was reprepped due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.I Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565250 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201175679 Method Blank (MB)1201175680 170683002(9106-0012-005F)

Sample Duplicate (DUP)1201175681 170683002(9106-0012-005F)

Matrix Spike (MS)1201175682 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 51 of 108 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683002 (9106-0012-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 170683001 (9106-0011-018F) and 170683006 (9106-0014-012F) were recounted due to high MDAs.Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Samples were dried and reweighed due to low matrix spike recovery.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565253 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683010 9106-0001-132F Page 52 of 108 1201175686 Method Blank (MB)1201175687 170683005(9106-0013-005F)

Sample Duplicate (DUP)1201175688 170683005(9106-0013-005F)

Matrix Spike (MS)1201175689 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683005 (9106-0013-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were perfonned within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Page 53 of 108 Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 564445 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 1201173840 Method Blank (MB)1201173841 170544018(9304-0002-005F)

Sample Duplicate (DUP)1201173842 170544018(9304-0002-005F)

Matrix Spike (MS)1201173843 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170544018 (9304-0002-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 54 of 108 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 564623 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201174253 Method Blank (MB)1201174254 170683001(9106-0011-018F)

Sample Duplicate (DUP)1201174255 170683001(9106-0011-018F)

Matrix Spike (MS)1201174256 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683001 (9106-0011-018F).

QC Information All of the QC samples met the required acceptance limits.Page 55 of 108 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201174254 (9106-0011-018F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 565648 Sample ID Client ID 170683010 9106-0001-132F 1201176786 Method Blank (MB)1201176787 170683010(9106-0001-132F)

Sample Duplicate (DUP)1201176788 170683010(9106-0001-132F)

Matrix Spike (MS)1201176789 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Page 56 of 108 Designated QC The following sample was used for QC: 170683010 (9106-0001-132F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565287 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201175808 Method Blank (MB)1201175809 170683006(9106-0014-012F)

Sample Duplicate (DUP)1201175810 170683006(9106-0014-012F)

Matrix Spike (MS)1201175811 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Page 57 of 108 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683006 (9106-0014-012F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201175810 (9106-0014-012F), 170683001 (9106-0011-018F), 170683002 (9106-0012-005F) and 170683006 (9106-0014-012F) were recounted due to the quench number being outside the calibration range.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 356906 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the sample 170683001 into the batch prior to analysis, however the samples did remain in their custody at all times. 1.The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Reporting results.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565291 Prep Batch Number: 564526 Page 58 of 108 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 170683010 9106-0001-132F 1201175818 Method Blank (MB)1201175819 170683004(9106-0013-006F)

Sample Duplicate (DUP)1201175820 170683004(9106-0013-006F)

Matrix Spike (MS)1201175821 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683004 (9106-0013-006F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 170683004 (9106-0013-006F) and 170683009 (9106-0015-002F) were recounted due to the quench number being outside the calibration range.Page 59 of 108 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565289 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201175814 Method Blank (MB)1201175815 170683006(9106-0014-012F)

Sample Duplicate (DUP)1201175816 170683006(9106-0014-012F)

Matrix Spike (MS)1201175817 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683006 (9106-0014-012F).

Page 60 of 108 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-], Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 565293 Prep Batch Number: 564526 Dry Soil Prep GL-RAD-A-021 Batch Number: 564525 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 170683010 9106-0001-132F 1201175822 Method Blank (MB)1201175823 170683004(9106-0013-006F)

Sample Duplicate (DUP)1201175824 170683004(9106-0013-006F)

Matrix Spike (MS)1201175825 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information Page 61 of 108 All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683004 (9106-0013-006F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 564447 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 1201173844 Method Blank (MB)1201173845 170544018(9304-0002-005F)

Sample Duplicate (DUP)1201173846 170544018(9304-0002-005F)

Matrix Spike (MS)1201173847 Laboratory Control Sample (LCS)Page 62 of 108 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170544018 (9304-0002-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201173846 (9304-0002-005F) and 1201173847 (LCS) were recounted due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 356177 was generated due to Container scanning event for custody missed. 1. Container scanning event for custody missed: The analyst did not scan the samples into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on proper scanning procedures.

Reporting results Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Page 63 of 108 Analytical Batch Number: 564514 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201174038 Method Blank (MB)1201174039 170683006(9106-0014-012F)

Sample Duplicate (DUP)1201174040 170683006(9106-0014-012F)

Matrix Spike (MS)1201174041 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683006 (9106-0014-012F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

Page 64 of 108 NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 565650 Sample ID Client ID 170683010 9106-0001-132F 1201176794 Method Blank (MB)1201176795 170683010(9106-0001-132F)

Sample Duplicate (DUP)1201176796 170683010(9106-0001-132F)

Matrix Spike (MS)1201176797 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683010 (9106-0001-132F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 65 of 108 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 564449 Sample ID Client ID 170683004 9106-0013-006F 170683005 9106-0013-005F 170683008 9106-0015-018F 170683009 9106-0015-002F 1201173848 Method Blank (MB)170544019(9304-0002-008F)

Sample Duplicate 1201173849 (DP (DUP)1201173850 170544019(9304-0002-008F)

Matrix Spike (MS)1201173851 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170544019 (9304-0002-008F).

Page 66 of 108 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 1201173849 (9304-0002-008F) was recounted due to a negative result greater than three times the error.Samples 170683008 (9106-0015-018F) and 170683009 (9106-0015-002F) were recounted to verify results. Second counts being reported.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 564520 Sample ID Client ID 170683001 9106-0011-018F 170683002 9106-0012-005F 170683003 9106-0012-014F 170683006 9106-0014-012F 170683007 9106-0014-033F 1201174056 Method Blank (MB)1201174057 170683007(9106-0014-033F)

Sample Duplicate (DUP)1201174058 170683007(9106-0014-033F)

Matrix Spike (MS)1201174059 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 67 of 108 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Oualitv Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683007 (9106-0014-033F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconfonnance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 565649 Sample ID Client ID 170683010 9106-0001-132F 1201176790 Method Blank (MB)1201176791 170683010(9106-0001-132F)

Sample Duplicate (DUP)1201176792 170683010(9106-0001-132F)

Matrix Spike (MS)1201176793 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Page 68 of 108 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170683010 (9106-0001-132F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

G6 -UL IW Page 69 of 108 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 356906 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 11-SEP-06 Radiochemistry Specifications Process Instrument Type: Test / Method: Matrix Type: Client Code: LSC DOE RESL Fe-1, Modified Solid YANK Batch ID: Sample Numbers: 565287 See Below Potentially affected work order(s)(SDG):

170683 Application Issues: Container scanning event for custody missed Specification and Requirements Nonconformance

==

Description:==

1. The analyst did not scan the sample 170683001 into the batch prior to analysis, however the samples did remain in their custody at all times.NRG Disposition:
1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Reporting results.Originator's Name: Melanie Aycock Quality Review: Data Validator/Group Leader: Heather Anderson 11 -SEP-06 11-SEP-06 Director: Page 1 Page 70 of 108 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 356177 Revision No.: 1 COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 08-SEP-06 Radiochemistry Specifications Process Instrument Type: Test / Method: Matrix Type: Client Code: LSC EPA 906.0 Modified Solid YANK Batch ID: Sample Numbers: 564447 See Below Potentially affected work order(s)(SDG):

170543(MSR#06-1172),170544(MSR#06-1174),170683 Application Issues: Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. Container scanning event for custody missed: The analyst did not scan 1. The error has been corrected and the analyst has been instructed on the samples intot he batch prior to analysis, however the samples did proper scanning procedures.

Reporting results remain in their custody at all times.Originator's Name: Kenshalla Oston Quality Review: Data Validator/Group Leader: Melanie Aycock 08-SEP-06 08-SEP-06 Director: Page 1 Page 71 of 108 SAMPLE DATA

SUMMARY

Page 72 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOOI Connecticut Yankee Atomic Power Co.Client SDG: 170683 GEL Work Order: 170683 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by Page 73 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: 9106-0011-018F Project: YANK01204 Sample ID: 170683001 Client ID: YANKOO Matrix: SE Vol. Recv.: Collect Date: 17-MAY-06 Receive Date: 21-JUN-06 Collector:

Client Moisture:

36.3%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0277 Curium-242 U 0.00666 Curium-243/244 U -0.0167 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.148 Plutonium-239/240 U 0.00321 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.87 Rad Gas Flow Proportional Counting GFPC, Sr9o, solid-ALL FSS Strontium-90 U 0.00422 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U 3.33 Liquid Scint C14, SolidAllFSS Carbon-14 U 1 0.00 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 0.852 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.341+/-0.0418+/-0.0505+/-0.0348+/-0.269+/-0.174+/-11.1 0.0128 0.037 0.0388 0.289 0.144 8.90+/-0.042+1-0.0505+/-0.0349+/-0.270+/-0.174+/-11.1 0.0643 0.138 0.117 0.795 0.505 18.6 0.0271 10.9 0.140 86.4 0.485 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g TCI 09/14/06 0931 567705 1 MXA I 09/11/06 0919 565210 3 TC1 09/17/06 0214 567883 4 KSDI 09/11/06 1917 565250 6+1-0.0151 0.0123 +1-0.0151+/-6.35 5.16 +/-6.35+/-0.0818 0.0686 +/-0.0818+/-61.3 41.7 +/-61.3+/-0.291 0.235 +/-0.291 DFA I AXD2 MXP I KXR1 09/05/06 1123 564514 09/06/06 0035 564520 09/10/06 1419 565287 09/06/06 1232 564623 7 8 9 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/01/06 1328 564525 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified Page 74 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0011-018F Project: YANK0 1204 Sample ID: 170683001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I I-RC Modified 4 DOE EML HASL-300, Pu-I 1-RC Modified 5 DOE EML HASL-300, Pu-I I-RC Modified 6 EPA 905.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 89 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 38 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 89 (25/-,125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 51 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-0125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (15%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0011-018F 170683001 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 76 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: September 18, 2006 9106-0012-005F 170683002 SE 23-JUN-06 07-JUL-06 Client 23.4%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00725 Curium-242 U 0.00 Curium-243/244 U -0.00297 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0214 Plutonium-239/240 U 0.120 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -10 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00415 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.39 Liquid Scint C14, SolidAllFSS Carbon-14 U -0.0271 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.71 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.04 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.057 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.0262+/-0.0343+/-0.0249+/-0.203+/-0.237+/-8.47 0.0156 0.00 0.0111 0.159 0.134 7.55+/-0.0262+/-0.0343+/-0.025+/-0.203+/-0.238+/-8.47+/-0.016 0.0141 +/-0.016 0.0644 0.0474 0.0557 0.498 0.449 15.8 0.0332 9.42 0.141 71.6 12.9 0.464 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA I 09/11/06 0919 565210 3 TC1 09/17/06 0230 567883 4 KSDI 09/08/06 1803 565250 6 TCI 09/14/06 0931 567705 1+/-5.57+/-0.0822+/-50.4+/-7.63+/-0.270 4.46 0.0694 34.5 6.28 0.225+/-5.57+/-0.0822+/-50.4+/-7.63+/-0.270 DFAI AXD2 MXPI MXPI KXRI 09/05/06 1155 564514 09/06/06 0253 564520 09/10/06 1435 565287 09/08/06 0035 565289 09/06/06 1249 564623 7 8 9 10 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/01/06 1328 564525 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified Page 77 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0012-005F 170683002 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 2 3 4 5 6 7 8 9 10 II DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-11-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-1, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery l est Recovery%

Acceptable Limits Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 90 47 78 99 67 85 82 (15%-125%)

(15%-125%)

(25%-125%)

(25%-/125%)

(15°/o-125%)

(25%-125%)

(15'/,12 5%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Page 78 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0012-005F 170683002 Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 79 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: September 18, 2006 9106-0012-014F 170683003 SE 21-JUN-06 07-JUL-06 Client 24.1%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.012 Curium-242 U -0.00814 Curium-243/244 U -0.00571 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00589 Plutonium-239/240 U 0.0588 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.22 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0176 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.38 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.00209 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 13.9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.26 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.269 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.0233+1-0.0351+/-0.0246+/-0.322+/-0.218+/-11.5 0.00 0.0215 0.0151 0.272 0.147 9.47+/-0.0234+/-0.0351+/-0.0246+/-0.322+/-0.218+/-11.5+/-0.0191 0.0133 +/-0.0191 0.032 0.089 0.0624 0.744 0.494 19.8 0.0316 10.7 0.127 50.7 13.9 0.470 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA I 09/11/06 0919 565210 3 TC1 09/17/06 0246 567883 4 KSD1 09/08/06 1803 565250 6 TC1 09/14/06 0931 567705 1+/-6.13+/-0.0745+/-36.7+/-8.20+/-0.281 5.08 0.0625 24.3 6.78 0.228+/-6.13+/-0.0745+/-36.7+/-8.20+/-0.281 DFAI AXD2 MXPI MXPI KXR1 09/05/06 1226 564514 09/06/06 0501 564520 09/07/06 2253 565287 09/08/06 0106 565289 09/06/06 1305 564623 7 8 9 10 II The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/01/06 1328 564525 The following Analytical Methods were performed Method Description DOE EML HASL-300, Am-05-RC Modified Page 80 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0012-014F 170683003 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 2 3 4 5 6 7 8 9 10 I1I DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%95 44 84 100 70 79 81 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(25%-/125%)

(15%-125%)

(25%-6125%)

(15%/,125

%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Page 81 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0012-014F 170683003 Project: YANKO1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 82 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Report Date: September 18, 2006 9106-0013-006F 170683004 SE 21-JUN-06 21-JUL-06 Client Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.187 Curium-242 U -0.0387 Curium-243/244 U -0.00608 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.012 Plutonium-239/240 U -0.0601 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 16.2 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.000813 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.997 Liquid Scint C14, SolidAllFSS Carbon-14 U -0.0199 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 33.7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.395 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0409 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.170+/-0.0438+/-0.118+/-0.0236+/-0.0526+/-13.4 0.0339 0.0836 0.102 0.045 0.100 10.8+/-0.172+/-0.0442+/-0.118+/-0.0236+/-0.0531+/-13.5 0.170 0.313 0.308 0.226 0.337 22.3 0.036 8.39 0.192 71.2 16.2 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA M MXA I MXA I 09/12/06 0844 565213 1 09/11/06 0919 565214 2 09/12/06 2245 565216 3+/-0.0187 0.0156 +/-0.0187 KSD1 09/08/06 1932 565253 4+/-4.80+/-0.109+/-51.9+/-9.40 3.98 0.0921 34.2 7.88+/-4.80+/-0.109+/-52.0+/-9.40 DFAI AXD2 MXPI MXP1 09/05/06 1847 564447 09/06/06 0955 564449 09/11/06 1150 565291 09/08/06 2220 565293 5 6 7 8+/-0.273 0.231 +/-0.273 0.475 KXR1 09/06/06 1637 564445 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 905.0 Modified Page 83 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0013-006F Project: YANK01204 Sample ID: 170683004 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-1, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 86 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 60 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 100 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%- 125%)Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 43 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 84 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Report Date: September 18, 2006 9106-0013-005F 170683005 SE 2 1-JUN-06 21 -JUL-06 Client Project: YANKO 1204 Client ID: YANKOO0 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.505 Curium-242 U 0.00 Curium-243/244 U 0.0327 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.008 Plutonium-239/240 U -0.0399 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 7.84 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U-0.000759 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.175 Liquid Scint C14, SolidAllFSS Carbon-14 U -0.0246 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 8.33 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -1.92 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0807 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.295+/-0.119+/-0.0868+/-0.0157+/-0.035+/-13.5 0.0542 0.00 0.0387 0.0299 0.0668 11.1+/-0.304+/-0.119+/-0.0869+/-0.0157+/-0.0352+1-13.5 0.224 0.165 0.194 0.150 0.224 22.8 0.0313 8.45 0.188 55.3 9.32 0.468 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA M MXA I 09/12/06 0844 565213 1 09/11/06 0919 565214 2 MXA 09/12/06 2332 565216 3 1 KSDl 09/08/06 1932 565253 4+/-0.0157 0.0133 +/-0.0157+/-4.77+/-0.107+/-39.2+/-5.36+/-0.273 4.01 0.0905 26.6 4.55 0.227+/-4.77+/-0.107+/-39.2+/-5.36+/-0.273 DFA I AXD2 MXPI MXPI KXRI 09/05/06 1919 564447 09/06/06 1027 564449 09/08/06 0121 565291 09/08/06 2323 565293 09/06/06 1654 564445 5 6 7 8 9 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 85 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0013-005F 170683005 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 9 EPA 906.0 Modified EPA EERF C-0I Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Te-t Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fc55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%68 86 71 101 71 72 80 Acceptable Limits (15°1-6125%)

(15%-125%/)

(25%-/125%)

(25%-125%)

(15%-125%)

(25%-/125%)

(15%/-I125%0/)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 86 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Report Date: September 18, 2006 9106-0014-012F 170683006 SE 06-JUN-06 13-JUL-06 Client Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.0945 Curium-242 U 0.0191 Curium-243/244 U 0.0473 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.113 Plutonium-239/240 U -0.097 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.84 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00246 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.44 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0486 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -12.6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.82 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0865 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.0698+/-0.0374+/-0.0497+/-0.329+/-0.0951+/-11.6 0.0158 0.00 0.0113 0.328 0.181 9.54+/-0.0709+/-0.0375+1-0.050+/-0.330+/-0.0963+/-11.6+/-0.00901 0.00776 +/-0.00901 0.0654 0.0517 0.0567 0.930 0.637 20.0 0.0169 10.7 0.130 63.6 13.2 0.481 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA I 09/11/06 0919 565210 3 TCl 09/17/06 0302 567883 4 KSDI 09/11/06 1917 565250 6 TC1 09/14/06 0931 567705 1+/-6.25+/-0.0773+/-44.5+/-7.80+/-0.281 5.07 0.064 30.6 6.44 0.234+/-6.25+/-0.0773+/-44.5+/-7.80+/-0.281 DFAI AXD2 MXPI MXP1 KXR1 09/05/06 1258 564514 09/06/06 0635 564520 09/10/06 1451 565287 09/08/06 0138 565289 09/06/06 1321 564623 7 8 9 10 II The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 DOE EML HASL-300, Pu-I I-RC Modified 6 EPA 905.0 Modified Page 87 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0014-012F 170683006 Proiect: YANKO1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 8 9 10 II EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML lHASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%93 33 84 91 74 80 79 Acceptable Limits (15%- 125%)(15%-I125%)

(25%- 125%)(25%-/125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 88 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

9106-0014-033F 170683007 SE 14-JUN-06 13-JUL-06 Client Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 Curium-242 U Curium-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0906 0.0195 0.0799+/-0.0692+/-0.0383+/-0.0639 0.0118 0.00 0.00+/-0.0703+/-0.0384+/-0.0648 0.0396 +/-0.254 0.229 +/-0.254 Plutonium-239/240 U -0.203 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.34 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00411 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.13 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.0995 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.3 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 4.62 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.00+/-0.182 0.244 +/-0.184+/-11.1 9.14 +/-11.1+/-0.0167 0.0133 +/-0.0167+/-5.10 4.12 +/-5.10+/-0.0918 0.075 +/-0.0918+/-37.9 24.9 +/-37.9+/-7.14 5.88 +/-7.14+/-0.282 0.236 +/-0.282 0.0594 0.053 0.0361 0.638 0.666 19.2 0.0316 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g TCI 09/14/06 0931 567705 1 MXA 09/11/06 0919 565210 3 1 TCI 09/17/06 0319 567883 4 KSDI 09/08/06 1803 565250 6 DFA1 09/05/06 1330 564514 7 AXD2 09/06/06 0807 564520 8 MXP1 09/07/06 2326 565287 9 MXPI 09/08/06 0209 565289 10 KXR1 09/06/06 1338 564623 11 8.71 pCi/g 0.153 pCi/g 51.8 pCi/g 12.1 pCi/g 0.487 pCi/g The following Analytical Methods were performed Method Description 1 2 3 4 5 6 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-11-RC Modified EPA 905.0 Modified Page 89 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0014-033F 170683007 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 8 9 10 II EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%87 41 89 99 76 84 78 Acceptable Limits (15%-125%)

(15%-125%)

(25%-/125o%)

(25%-125%)

(15/-,125%)

(25%-.125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 90 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gelcomrn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Report Date: September 18, 2006 9106-0015-018F 170683008 SE 27-JUN-06 21-JUL-06 Client Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Re Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0 Curium-242 U 0.1 Curium-243/244 U 0.(Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(Plutonium-239/240 U 0.(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.(Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0 esuit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd'.193 0784 0942 0325 0013 7.19.686 0572 7.27 2.39.132+/-0.166+/-0.147+/-0.129+/-0.0637+/-0.0705+/-12.0+/-5.32+/-0.114+/-37.9+/-7.60+/-0.270 0.00 0.0655 0.0474 0.00 0.0582 9.91 4.50 0.0942 25.6 6.43 0.223+/-0.168+/-0.147+/-0.130+/-0.0638+/-0.0705+/-12.1+/-5.32+/-0.114+/-37.9+/-7.60+/-0.270 0.101 0.271 0.196 0.0881 0.204 20.4 9.48 0.193 53.2 13.2 0.460 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA M MXA I MXA DFAI AXD2 MXPI MXP1 KXR1 09/12/06 0844 565213 1 09/11/06 0919 565214 2 09/13/06 0019 565216 3 09/05/06 1950 564447 09/09/06 0331 564449 09/08/06 0137 565291 09/09/06 0025 565293 09/06/06 1710 564445 4 5 6 7 8 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- 11-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified 6 DOE RESL Fe-1, Modified 7 DOE RESL Ni-I, Modified Page 91 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0015-018F 170683008 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 86 79 79 47 82 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not'apply.

Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 92 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Report Date: September 18, 2006 9106-0015-002F 170683009 SE 28-JUN-06 21 -JUL-06 Client Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier R Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 Curium-242 U 0.Curium-243/244 U 0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAll,FSS Carbon- 14 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.292 0522 0289 0352 0.019 24.6-1.6 0.207 10.8-3.07 0.390+/-0.213+/-0.102+/-0.0766+/-0.0798+/-0.0758+/-16.2+/-7.22+/-0.113+/-47.1+/-6.78 0.0479 0.00 0.0341 0.0658 0.0465 13.0 6.13 0.0898 31.3 5.76+/-0.217+/-0.103+/-0.0767+/-0.0798+/-0.0758+/-16.5+/-7.22+/-0.113+/-47.1+/-6.78 0.198 0.141 0.171 0.231 0.192 26.7 12.9 0.185 65.2 11.8 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA M MXA I MXA DFA I AXD2 MXPI MXPI 09/12/06 0844 565213 1 09/11/06 0919 565214 2 09/13/06 0106 565216 3 09/05/06 2022 564447 09/09/06 0418 564449 09/11/06 1206 565291 09/09/06 0127 565293 4 5 6 7+/-0.283 0.227 +/-0.283 0.468 KXRI 09/06/06 1726 564445 8 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified Page 93 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: 9106-0015-002F 170683009 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300.

Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 79 75 74 55 80 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on an "as received" basis.Page 94 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.160 Curium-242 U 0.00 Curium-243/244 0.132 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0279 Plutonium-239/240 U -0.0591 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 14.0 Rad Gas Flow Proportional Counting GFPC,,Sr90, solid ALL FSS Strontium-90 U 0.00619 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.94 Liquid Scint C14, SolidAllFSS Carbon-14 0.324 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.92 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.735 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0126 The following Prep Methods were performed Method Description 9106-0001-132F 170683010 SE 07-AUG-06 17-AUG-06 Client 23.8%LC TPU Uncertainty

+/-0.147+/-0.0754+/-0.130+/-0.0954+/-0.0934+/-14.7 0.0296 0.00 0.00 0.0976 0.0903 12.0+/-0.148+/-0.0754+/-0.131+/-0.0955+/-0.0934+/-14.8 MDA 0.148 0.104 0.0896 0.306 0.292 24.6 0.0311 12.0 0.183 53.9 10.0 0.330 Units DF Analyst Date Time Batch Mtd pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA 09/12/06 0844 565213 1 1 MXA 09/11/06 0919 565214 2 1 MXA 09/13/06 0153 565216 3 1 KSD1 09/08/06 1932 565253 4+/-0.0168 0.0131 +/-0.0168+/-7.02+1-0.115+/-38.0+/-5.83+/-0.193 5.55 0.0889 25.9 4.88 0.161+/-7.02+/-0.115+/-38.0+/-5.83+/-0.193 ATH2 AXD2 MXPI MXPI KXR1 09/07/06 0102 565650 09/08/06 0456 565649 09/08/06 0210 565291 09/09/06 0229 565293 09/12/06 1349 565648 5 6 7 8 9 Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description JMB 1 09/05/06 1736 565454 Page 95 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 18, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132F Project: YANK01204 Sample ID: 170683010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 87 (15%- 125%)Plutonium-242 Alphaspec Pu, Solid-ALL FSS 66 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu24l, Solid-ALL Fý 66 (25%-9125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 100 (25%- 125%)Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 ( 15%- 125%)Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 72 (15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Page 96 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 18, 2006 Client Sample ID: Sample ID: 9106-0001-132F 170683010 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 97 of 108 I .1 QUALITY CONTROL DATA Page 98 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: September 18, 2006 Page 1 of 10 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

170683 NW"As4 Rad Alpha Spec Batch 565210 1 QC Units RPD%REC% Range AnIst Date Time QC1201175592 170683001 DUP Plutonium-238 Plutonium-239/240 QC1201175594 LCS Plutonium-238 Plutonium-239/240 QC1201175591 MB Plutonium-238 Plutonium-239/240 QC1201175593 170683001 MS Plutonium-238 Plutonium-239/240 U -0.148 Uncert: +/-0.269 TPU: +/-0.270 U 0.00321 Uncert: +/-0.174 TPU: +/-0.174 Uncert: TPU: 12.3 Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.148 Uncert: +/-0.269 TPU: +/-0.270 12.5 U 0.00321 Uncert: +/-0.174 TPU: +/-0.174 0.187 Uncert: +/-0.170 TPU: +/-0.172 U -0.0387 Uncert: +/-0.0438 TPU: +/-0.0442 U -0.00608 Uncert: +/-0.118 TPU: +/-0.118 13.5 Uncert: TPU: U 0.137+/-0.303+/-0.304 U -0.215+/-0.181+/-0.183 U -0.0564+/-0.446+/-0.446 9.42+/- 1.98+/-2.49 U 0.117+/-0.220+/-0.221 U 0.0802+/-0.226+/-0.226 U 0.110+/-0.175+/-0.176 11.8+/-1.70+/-2.29 0.163+/-0.149+1-0.151 0.143+/-0.162+/-0.163 U -0.0487+/-0.0768+/-0.0769 12.8+/- 1.24+/-2.12 pCi/g 5180 pCi/g 206 pCi/g pCi/g (0% -100%) AXAI 09/11/06 09:19 (0%- 100%)(75%-125%)

77 (75%-125%)

pCi/g pCi/g pCi/g pCi/g (75%-125%)

94 (75%-125%)

Batch 565213 QC1201175603 170683004 DUP Americium-241 Curium-242 Curium-243/244 QC1201175605 LCS Americium-241 pCi/g 14 pCi/g 348 pCi/g 156 pCi/g (0%- 100%) .XAI 09/12/06 08:44 (0%- 100%)(0%- 100%)95 (75%-125%)

Page 99 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 2 of 10 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 565213 Curium-242 Curium-243/244 QC1201175602 MB Americium-241 Curiumn-242 Curium-243/244 QC1201175604 170683004 MS Americium-241 Curium-242 Curiumn-243/244 Uncert: TPU: 16.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.00+/-0.0625+/-0.0625 15.1+/-1.35+/-2.44 U 0.0812+/-0.107+/-0.108 U 0.0664+/-0.106+/-0.107 U -0.00886+/-0.0744+/-0.0745 pCilg pCilg pCilg pCilg pCilg pCilg pCilg pCi/g 92 (75%-125%)

09/12/06 08:44 Batch 565214 QCI201175607 170683004 DUP Plutonium-238 Plutonium-239/240 QC1201175609 LCS Plutoniumn-238 Plutonium-239/240 QC1201175606

.MB Plutonium-238 Plutonium-239/240 QC1201175608 170683004 MS 13.7 0.187 Uncen: +/-0.170 TPU: +/-0.172 U -0.0387 Uncert: +/-0.0438 TPU: +/-0.0442 16.7 U -0.00608 Uncert: +/-0.118 TPU: +/-0.118 U -0.012 Uncert: +/-0.0236 TPU: +/-0.0236 U -0.0601 Uncert: +/-0.0526 TPU: +/-0.0531 Uncert: TPU: 12.5 Uncert: TPU: Unceri: TPU: Uncert: TPU: 14.1+/-1.41+/-2.41 0.209+/-0.205+/-0.207 16.2+/-1.52+/-2.71 102 (75%-125%)

09/12/06 08:44 97 (75%-125%)

U -0.0415+/-0.0941+/-0.0941 U -0.0311+/-0.0917+/-0.0917 U 0.00142+/-0.0772+/-0.0772 10.7+/-1.21+/-1.66 U -0.0382+/-0.113+/-0.113 U -0.0891+/-0.066+/-0.0669 pCi/g 110 pCi/g 64 pCi/g pCi/g (0%- 100%) AXAI 09/11/06 09:19 (0%- 100%)(75%-125%)

86 (75%-125%)

pCi/g pCi/g Page 100 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 3 of 10 Parmname Rad Alpha Spec Batch Plutonium-238 NOM Sample Qual QC Units RPD%REC% Range Anist Date Time 565214 U -0.012 Uncert: +/-0.0236 TPU: +/-0.0236 12.6 U -0.0601 Uncert: +/-0.0526 TPU: +1-0.0531 U 0.0632+/-0.143+/-0.143 10.9+/-1.20+/- 1.66 pCi/g PCilg (75%-125%)

Plutonium-239/240 87 (75%-125%)

Batch 565216 QCI201175615 170683004 DUP Plutonium-241 QC1201175617 LCS Plutonium-241 QC1201175614 MB Plutonium-241 QC1201175616 170683004 MS Plutonium-241 Uncert: TPU: U 16.2+/-13.4+/-13.5 U 5.89+/-12.7+/-12.7 pCi/g 0 (0%- 100%) AIXAI 09/13/06 03:26 341 Uncert: TPU: Uncert: TPU: 344 U Uncert: TPU: 310+/-32.9+/-45.2 U 5.70+/-12.7+/-12.7 pCi/g pCilg PCi/g 91 (75%-125%)

09/12/06 11:26 09/13/06 02:39 09/12/06 11:10 16.2+/- 13.4+/-13.5 341+/-51.8+/-66.7 99 (75%-125%)

Batch 567705 QC1201181288 170683003 DUP Americium-241 Curium-242 Curium-243/244 QC1201181290 LCS Americium-241 Curium-242 Curium-243/244 QC1201181287 MB Americium-241 U 0.012 Uncert: +/-0.0233 TPU: +/-0.0234 U -0.00814 Uncert: +/-0.0351 TPU: +/-0.0351 u -0.00571 Uncert: +/-0.0246 TPU: +/-0.0246 5.23 Uncert: TPU: Uncert: TPU: 6.31 Uncert: TPU: Uncert: TPU: 0.120+/-0.0804+/-0.082 U 0.00+/-0.0381+/-0.0381 U -0.0196+/-0.031+/-0.031 5.41+/-0.508+/-0.878 U 0.00+/-0.0244+/-0.0244 6.40+/-0.553+/-1.01 U 0.00039+/-0.00421

+/-0.00421 pCi/g 164 pCi/g 200 pCi/g 110 pCi/g (0% -100%) TCI (0%- 100%)(0%- 100%)103 (75%-125%)

09/14/06 09:31 pCi/g pCi/g pCi/g 101 (75%-125%)

09/14/06 09:31 Page 101 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 4 of 10 REC% Ranie Anist Date Time Parmname NOM Samole Oual OC Units RPD%Rad Alpha Spec Batch 567705 Curium-242 Curium-243/244 QC1201181289 170683003 MS Americium-241 Curium-242 Curium-243/244 Uncert: TPU: Uncert: TPU: 5.27 U 0.012 Uncert: +/-0.0233 TPU: +/-0.0234 U -0.00814 Uncert: +/-0.0351 TPU: +/-0.0351 6.41 U -0.00571 Uncert: +/-0.0246 TPU: +/-0.0246 U 9.87 Uncert: +/-11.1 TPU: +/-11.1 U 0.00902+/-0.0239+/-0.0239 U -0.00283+/-0.0238+/-0.0238 5.58+/-0.524+/-0.908 U 0.0183+/-0.0359+/-0.036 7.36+/-0.603+1-1.15 pCi/g pCi/g pCi/g pCi/g pCi/g 106 (75%-125%)

09/14/06 09:31 115 (75%-125%)

Batch 567883 QC1201181752 170683001 DUP Plutonium-241 U QC1201181754 Plutonium-241 LCS-3.06+/-10.4+/-10.4 120+/-16.2+/-19.8 QC1201181751 MB Plutonium-241 135 Uncert: TPU: Uncert: TPU: 142 U Uncert: TPU: pCi/g pCi/g pCi/g pCi/g 89 (75%-125%)

(0%- 100%) TCI 09/17/06 03:51 09/17/06 04:24 09/17/06 03:35 09/17/06 04:08 U 1.78+/-9.61+/-9.61 QC1201181753 170683001 MS Plutonium-241 9.87+/-11.1+/-I 1.1 113+/-15.8+/-19.1 80 (75%-125%)

Rad Gas Flow Batch 565250 QC1201175680 170683002 DUP Strontium-90 QC1201175682 LCS Strontium-90 QC1201175679 MB Strontium-90 QCI201175681 170683002 MS Strontium-90 U -0.00415 Uncert: +/-0.016 TPU: +/-0.016 1.56 Uncert: TPU: Uncert: TPU: 3.13 U -0.00415 U 0.000131+/-0.0253+/-0.0253 1.63+1-0.151+/-0.155 U -0.00458+/-0.018+/-0.018 pCi/g 0 (0% -100%) KSDI pCi/g pCi/g 105 (75%-125%)

09/08/06 18:03 09/08/06 18:05 09/08/06 18:03 09/08/06 18:03 2.38 pCi/g 76 (75%-125%)

Page 102 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 5 of 10 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Gas Flow Batch 565250 565253 Batch QC1201175687 170683005 DUP Strontium-90 QC1201175689 LCS Strontium-90 QC1201175686 MB Strontium-90 QCI201175688 170683005 MS Strontium-90 Rad Liquid Scintillation Batch 564445 QC1201173841 170544018 DUP Technetium-99 QC1201173843 LCS Technetium-99 QC1201173840 MB Technetium-99 QC1201173842 170544018 MS Technetium-99 Uncert: +/-0.016 TPU: +/-0.016 U -0.000759 Uncert: +/-0.0157 TPU: +/-0.0157+/-0.249+/-0.253 U -0.000963+/-0.0166+/-0.0166 pCi/g 0 (0%- 100%) KSDI 09/08/06 19:32 1.57 Uncert: TPU: Uncert: TPU: 3.14 U Uncert: TPU: 1.20+/-0.113+/-0.118 U -0.0216+/-0.00992

+/-0.00992 pCi/g pCi/g pCi/g 77 (75%-125%)

09/09/06 12:26 09/08/06 19:32 09/08/06 19:31-0.000759+/-0.0157+/-0.0157 2.77+/-0.189+/-0.205 88 (75%-125%)

U 0.128 Uncert: +/-0.272 TPU: +/-0.272 U 0.0496+/-0.251+/-0.251 13.0+1-0.501+/-0.582 pCi/g 0 (0% -100%) KXRI 12.7 Uncert: TPU: Uncert: TPU: 13.1 U Uncert: TPU: U 0.0991+/-0.243+/-0.243 pCi/g pCi/g pCi/g 103 (75%-125%)

09/06/06 17:59 09/06/06 18:32 09/06/06 17:43 09/06/06 18:15 0.128+/-0.272+/-0.272 Batch 564447 QC1201173845 170544018 DUP Tritium U 1.53 Uncert: +/-6.54 TPU: +/-6.54 U 13.3+/-0.540+/-0.620 0.760+/-5.24+/-5.24 44.3+/-8.94+/-8.98 102 (75%-125%)

pCi/g pCi/g (0%- 100%) DFA1 09/05/06 21:25 QC1201173847 LCS Tritium QC1201173844 MB Tritium 46.9 Uncert: TPU: 95 (75%-125%)

09/07/06 11:21 09/05/06 20:54 U -0.43 pCi/g Page 103 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Parmname Rad Liquid Scintillation Batch 564447 Page 6 of 10 REC% Range Anist Date Time NOM Uncert: TPU: 54.5 U Uncert: TPU: Sample Oual OC Units RPD%QC1201173846 170544018 MS Tritium 1.53+/-6.54+/-6.54 Batch 564449 QC1201173849 Carbon-14 170544019 DUP+/-4.67+/-4.67 57.4+/-10.7+/-10.7-0.0804+/-0.108+/-0.108 6.26+/-0.258+/-0.276 pCi/g 105 (75%-125%)

09/07/06 11:05 U -0.0997 Uncert: +/-0.0966 TPU: +/-0.0966 U pCi/g 0 (0%- 100%) NXD2 09/09/06 05:04 QC1201173851 LCS Carbon- 14 QC1201173848 MB Carbon- 14 QC1201173850 170544019 MS Carbon-14 6.66 Uncert: TPU: Uncert: TPU: 6.86 U Uncert: TPU: U -0.0326+/-0.102+/-0.102 pCi/g pCilg pCilg 94 (75%-125%)

09/06/06 13:38 09/06/06 12:02 09/06/06 13:07-0.0997+/-0.0966+/-0.0966 6.85+/-0.273+/-0.293 100 (75%-125%)

Batch 564514 QC1201174039 170683006 DUP Tritium U 3.44 Uncert: +/-6.25 TPU: +/-6.25 U 1.46+/-5.79+/-5.79 pCi/g 0 (0% -100%) DFA1 QC1201174041 LCS Tritium QC1201174038 MB Tritium 48.4 Uncert: TPU: Uncert: TPU: 49.1 U Uncert: TPU: 53.7+/-7.25+/-7.31 U 0.308+/-4.66+/-4.66 pCi/g pCi/g pCi/g 111 (75%-125%)

09/05/06 14:33 09/05/06 15:36 09/05/06 14:01 09/05/06 15:05 QC1201174040 170683006 MS Tritium 3.44+/-6.25+/-6.25 Batch 564520 QC1201174057 170683007 DUP Carbon-14 QC1201174059 LCS Carbon- 14 U 0.0995 Uncert: +/-0.0918 TPU: +/-0.0918 U 61.1+/-7.58+/-7.65 0.0741+/-0.118+/-0.118 6.51+/-0.263+/-0.282 124 (75%-125%)

pCi/g 0 (0% -100%) NXD2 09/06/06 10:24 09/06/06 11:28 6.58 Uncert: TPU: pCi/g 99 (75%-125%)

Page 104 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 7 of 10 REC% Ranee Anist Parmname NOM Sample Oual OC Units RPD%Date Time Rad Liquid Scintillation Batch 564520 QC1201174056 MB Carbon-14 Uncert: TPU: U -0.0231+/-0.105+1-0.105 pCilg pCi/g 09/06/06 09:53 09/06/06 10:56 QC1201174058 170683007 MS Carbon-14 7.19 U Uncert: TPU: 0.0995+/-0.0918+/-0.0918 Batch 564623 QC1201174254 170683001 DUP Technetiurn-99 QC1201174256 LCS Technetium-99 QC1201174253 MB Technetium-99 QC1201174255 170683001 MS Technetium-99 U 0.341 Uncert: +/-0.29 I TPU: +/-0.291 U 6.42+/-0.276+/-0.293 0.187+/-0.211+/-0.211 12.2+/-0.490+/-0.566 89 (75%-125%)

pCi/g 0 (0% -100%) KXRI 13.0 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: U 0.151+/-0.247+/-0.247 pCi/g pCi/g pCi/g 94 (75%-125%)

09/08/06 19:42 09/06/06 14:43 09/06/06 13:54 09/06/06 14:27 0.341+/-0.291+/-0.291 12.9+/-0.547+/-0.623 99 (75%-125%)

Batch 565287 QC1201175809 170683006 DUP Iron-55 QC0201175811 LCS Iron-55 QC1201175808 MB Iron-55 QC1201175810 170683006 MS Iron-55 U -12.6 Uncert: +/-44.5 TPU: +/-44.5 U 38.3+/-41.2+/-41.2 pCi/g 0 (0% -100%) vIXPI 628 Uncert: TPU: Uncert: TPU: 746 U Uncert: TPU: 613+/-56.2+/-67.5 U 10.2+/-35.9+/-35.9 pCi/g pCi/g pCi/g 98 (75%-125%)

09/07/06 23:59 09/08/06 00:31 09/07/06 23:42 09/10/06 15:07-12.6+/-44.5+/-44.5 675+/-60.5+/-73.4 91 (75%-125%)

Batch 565289 QC1201175815 170683006 DUP Nickel-63 QC1201175817 LCS Nickel-63 Uncert: TPU: U 4.82+/-7.80+/-7.80 U 6.11+/-9.03+/-9.03 pCi/g 0 (0%- 100%) VIXPI 09/08/06 03:13 512 443 pCi/g 87 (75%-125%)

09/08/06 04:16 Page 105 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 8 of 10 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 565289 QC1201175814 MB Nickel-63 Uncert: TPU: Uncert: TPU:+/-15.2+/-20.8 U 5.67+/-7.44+/-7.44 pCi/g pCi/g 09/08/06 02:41 09/08/06 03:44 QC1201175816 170683006 MS Nickel-63 572 U Uncert: TPU: 4.82+/-7.80+/-7.80 Batch 565291 QC1201175819 170683004 DUP Iron-55 QC1201175821 LCS Iron-55 QCI201175818 MB Iron-55 QC1201175820 170683004 MS Iron-55 U 33.7 Uncert: +/-51.9 TPU: +/-52.0 U 475+/-15.4+/-22.2-4.73+/-40.3+/-40.3 652+/-52.2+/-64.9 83 (75%-125%)

pCi/g 0 (0% -100%) vXPI 628 Uncert: TPU: Uncert: TPU: 711 U Uncert: TPU: U -26.7+/-35.6+/-35.6 pCi/g pCi/g pCi/g 104 (75%-125%)

09/08/06 02:42 09/08/06 03:15 09/08/06 02:26 09/08/06 02:59 33.7+/-51.9+/-52.0 Batch 565293 QC1201175823 170683004 DUP Nickel-63 QC1201175825 LCS Nickel-63 QC1201175822 MB Nickel-63 QC1201175824 170683004 MS Nickel-63 Uncert: TPU: U 0.395+/-9.40+/-9.40 1J 744+/-60.1+/-75.2 0.122+/-7.25+/-7.25 467+/- 15.4+/-21.5 512 Uncert: TPU: Uncert: TPU: 531 U Uncert: TPU: pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) vIXPI 105 (75%-125%)

91 (75%-125%)

09/09/06 04:34 09/09/06 06:38 09/09/06 03:32 09/09/06 05:36 U -2.47+/-5.58+/-5.58 0.395+/-9.40+/-9.40 Batch 565648 535+/-21.6+/-27.8 0.0841+/-0.206+/-0.206 101 (75%-125%)

QC1201176787 170683010 DUP Technetium-99 U 0.0126 Uncert: +/-0.193 TPU: +/-0.193 U pCi/g 0 (0%- 100%) K.XRI 09/12/06 14:53 Page 106 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 9 of 10 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Liquid Scintillation Batch 565648 QC1201176789 LCS Technetium-99 QC1201176786 MB Technetium-99 QC1201176788 170683010 MS Technetium-99 13.1 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: 13.2+/-0.349+/-0.480 U 0.00238+/-0.154+/-0.154 pCilg pCilg pCilg 101 (75%-125%)

09/12/06 15:56 09/12/06 14:21 09/12/06 15:24 0.0126+/-0.193+/-0.193 Batch 565649 QC1201176791 170683010 DUP Carbon-14 QC1201176793 LCS Carbon-14 QC1201176790 MB Carbon- 14 QC1201176792 170683010 MS Carbon- 14 0.324 Uncert: +/-0.115 TPU: +1-0.115 12.1+/-0.383+/-0.489 0.204+/-0.112+/-0.112 8.39+/-0.256+/-0.288 93 (75%-125%)

pCi/g 46 (0%- 100%) ,XD2 09/08/06 07:38 7.27 Uncert: TPU: Uncert: TPU: 7.22 Uncert: TPU: U 0.0136+/-0.109+/-0.109 pCilg pcilg pCilg 115 (75%-125%)

09/08/06 09:12 09/08/06 06:51 09/08/06 08:25 0.324+1-0.115+1-0.115 7.14+/-0.239+/-0.264 94 (75%-125%)

Batch 565650 QC1201176795 170683010 DUP Tritium U 4.94 Uncert: +/-7.02 TPU: +/-7.02 U 7.42+/-7.37+/-7.37 pCi/g 0 (0% -100%) ATH2 QCt201176797 Tritium LCS QC1201176794 MB Tritium 64.5 Uncert: TPU: Uncert: TPU: 64.7 U Uncert: TPU: 64.9+/-10.8+/-10.8 U 4.55+/-6.87+/-6.87 pCi/g pCi/g pCi/g 101 (75%-125%)

09/07/06 01:36 09/07/06 02:09 09/07/06 01:19 09/07/06 01:52 QC1201176796 170683010 MS Tritium 4.94+/-7.02+/-7.02 67.5+/-10.9+/-10.9 104 (75%-125%)

Page 107 of 108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170683 Page 10 of 10 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.Page 108 of 108 Table of Contents G eneral N arrative ...................................................................

1 Chain of Custody And Supporting Dpcumentation

...........

5 Radiological Analysis ...........................................................

12 Sam ple Data Sum m ary .......................................................

18 Q uality C ontrol D ata ............................................................

60 General Narrative CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170256 SDG: MSR #06-1160 September 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailin2 Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road-Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on August 25, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and. signatures.

The laboratory received the following sample(s):

Sample ED Client Sample ID 170256001 9106-0006-005A 170256002 9106-0006-005B 170256003 9106-0006-005C 170256004 9106-0006-005D 170256005 9106-0005-0IOA 170256006 9106-0005-OIOB 170256007 9106-0005-OIOC 170256008 9106-0005-010D 170256009 9106-0014-033A GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171

  • Fax 243) 766-1178
  • www.gel.com 170256010 9106-0014-033B 170256011 9106-0014-033C 170256012 9106-0014-033D 170256013 9106-0004-013A 170256014 9106-0004-013B 170256015 9106-0004-013C 170256016 9106-0004-013D 170256017 9106-0004-005A 170256018 9106-0004-005B 170256019 9106-0004-005C 170256020 9106-0004-005D Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engr~eering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Twenty soil samples were analyzed for FSSGAM and Sr-90.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically apd for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager orla designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC. T P.O. Box 30712 o Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171 -Fax i43) 766-1178 -www.gel.com List of current GEL Certifications as of 06 September 2006 State Alaska Arizona Arkansas CLIA California

.Colorado--Connecticut Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas____Kentucky

..Maryland-Massachusetts SMichigan Nevada New Jersey New York North Carolina North Carolina Drinking W North Dakota Oklahoma---- Pennsylvania South Carolina Tennessee Texas US. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 88-0651 42D0904046 6115CA 1-C...... .--- enngLabs .. ..PH-0169 NFESC4I13 W--L6-5J ....E87156 E871 56(FLJNELAP)

N/A 200029 C-SC-) I-E-10332 270 M-SC012 9903 SC 12-SCO02 f 1 501 233 45709 R-158 9904 68-485 10120001/10585001/10120002 02934 TX213-2006A S-52597 N/A..... 8037697376 GEL N/A 00151 C223 4 Chain of Custody And Supporting Documentation i I -5 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00511 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones U0 C Priority:

[] 30 D. Z 14 D. [] 7 D. Container K- O ""'5Z_ f.Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample MI)9106-0006-005A 8/8/06 14:35 SE C BP X X Transferred from COC N 2006-00488 9106-0006-005B 8/8/06 15:08 SE C BP x X Transferred from COC # 2006-00488 9106-0006-005C 8/9/06 07:46 SE C BP X X Transferred from COC # 2006-00307 9106-0006-005D 8/9/06 08:18 SE C BP X X Transferred from COC # 2006-00307 NOTES: PO#: 002332 MSR #: 06-116O SSWP#NA Z LTP QA E] Radwaste QA El Non QA 1) Relinquished By 3 A M C-4or& "-Date/Timeý-Za4-0ý/1 3'(i Samples Shipped Via: Z Fed Ex[Ikips El Hand El Other Bill of Lading #"-00o 4 Internal Container Temp.: __ Deg. C Custody Sealed?YO- NO Custody Seal Intact?YE NO 3) Relinquished By Date/Time I Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00512 362 Irijun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C C Priority:

E] 30 D. Z] 14 D.E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0005-01OA 8/9/06 09:03 SE C BP X X Transferred from COC # 2006-00489 9106-0005-010B 8/9/06 09:33 SE C BP x x Transferred from COC # 2006-00489 9106-0005-OIOC 8/9/06 10:04 SE C BP X X Transferred from COC # 2006-00489 9106-0005-OIOD 8/9/06 10:56 SE C BP x x Transferred from COC # 2006-00489 NOTES: PO #: 002332 MSR#: 06- 1!40 SSWP# NA Z LTP QA El Radwaste QA El Non QA 1) Relinquished By ime 2) ceived By ..D te/Time 3) Relinquished By DatefTime ceived By Samples Shipped Via: 0 Fed Ex E0 UPs El Hand[ Other Bill of Lading #Sq 00 4631 4Z3 Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YoI NO]

Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 I Major I.Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00513 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddamn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones un Cn Priority:

[] 30 D. Z 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0014-033A 8/11/06 07:58 SE C BP X X Transferred from COC # 2006-00493 C9106-0014-033B 8/11/06 08:24 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033C 8/11/06 08:45 SE C BP x x Transferred from COC # 2006-00493 9106-0014-033D 8/11/06 09:16 SE C BP X X Transferred from COC # 2006-00493 NOTES: PO #: 002332 MSR #: 06-1160 SSWP# NA Z LTP QA E3 Radwaste QA El Non QA Relinquished By Date/Time ,¢-q 13 2)/ived By A I'hl~, Jý2,44_iz Samples Shipped Via:[ Fed Ex 13 uPs[] Hand 1] Other Bill of Lading #9e'Q 40Y'q 644q Internal Container Temp.: _ Deg. C-Custody Sealed?YOI No Custody Seal Intact?YD NEI Date/Time 3) Relinquished By Date/Time

4) R e&-ed By -7 lap, Date/Time Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00520 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn ci d Priority:E]30D.

14D.[117D.

Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0004-013A 8/9/06 12:53 SE C BP X X Transferred from COC 2006-00490 9106-0004-013B 8/9/06 13:27 SE C BP X X Transferred from COC 2006-O0490 "9106-0004-013C 8/9/06 13:57 SE C BP X X Transferred from COC 2006-00490 9106-0004-013D 8/9/06 14:28 SE C BP X X Transferred from COC 2006-00490 9106-0004-OOSA 8/9(06 14:58 SE C BP X X Transferred from COC 2006-00490 9106-0004-005B 8/10/06 07:41 SE C BP x x Transferred from COC 2006-00491 9106-0004-005C 8/10/06 08:09 SE C BP X X Transferred from COC 2006-00491 9106-0004-005D 8/10/06 08:49 SE C BP X X Transferred from C OC 2006-00491 NOTES: PO#: 002332 MSR#: 06-11 0 SSWP#NA 0 LTP QA EJ Radwaste QA EL Non QA I) Relinquished By Datei ime 1-Z4 / 13 40 2) Teqived~y/

Date/Time i/k A L Samples Shipped Via: Z Fed Ex El UPS El Hand E] Other Bill of Lading #7q00 4b.3' 0471(Internal Container Temp.: __ Deg. C Custody Sealed?Y-0 NO Custody Seal Intact?YO NO 3) Relinquished By Date/Time

ý4 ceived Byit DatetTime Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW=001 CY-lsC-sOw-ool Figure 1. Sample Check-in List Date/Time Received: SDG#: Work Order Number: !Shipping Cdntainar ID:7,4. Chain of Custody#.,FDO4 40'5"Z3 tC--1. Custody Seals od shipping container intact?.,, -Yes 1- o [2. Custody Seals dated and signed? Yes' L[ýo I ]3. Chain-of-Custody record prýsent? Yesf[.-t..

,,.4. Cooler temperature

5. Vermiculite/packing materials is: Wet i(]6.' Number of samples in shipping container:

__'__ _.7. Sample holding times exceeded?

Yes [,,go [I.1.8.Samples have:-se..cwltody Seals.-. hazard labels-appropriate sample labels 9. Samples are-_.gznw good condition broken-leaking'---have air bubbles 10.11.Were any anomalies identified in sample receipt? Yes [ ] No [1 1 Description of anomalies (include sample numbers):

I-Telephoned 10

ý_-CyjSCS0w_00l Connecticut Yankee Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List DatelTime Rec ved: " */, , SDG#: _Work Order Nuriber: Shipping Cdhtainer ID;:2 e027_ý9' Chain of Custody # 42e' i -6 .%i2--1. Custody Seals. oi shipping container intact?. -Yes [ 4o]2. Custody Seals dated and signed? Yes f'-No [G .3. Chain-of-Custody record prenset? Yes f.i 1 o r Ii 4. Cooler temperature

.2 '-5. Verniculite/packing materials is: Wet , 6.' Number of samples in shipping container:

_,, .7. Sample holding times ex ceeded? Yes Vri1o[I.8. Sarmples hv:/* *" " "" /-"/have.-. "hazard labels " " "" ( ,* .ustody seals -appropriate sample labels " " '.i 9. Samples are.-__ý_in gold condition...~iroe. .........-

have air bubbles 10. Were any anognalies identified in sample receipt? Yes (&<N i!11 ..Description oflanomalies, (include sample numbers):

Z_)-z=- z' , )0b ,*, 11 RADIOLOGICAL ANALYSIS 12 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170256 Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 170256001 170256002 170256003 170256004 170256005 170256006 170256007 170256008 170256009 170256010 170256011 170256012 170256013 170256014 170256015 170256016 170256017 170256018 170256019 170256020 1201171525 1201171526 1201171527 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 563436 562444 Client ID 9106-0006-005A 9106-0006-005B 9106-0006-005C 9106-0006-005D 9106-0005-01OA 9106-0005-01OB 9106-0005-OIOC 9106-0005-OIOD 9106-0014-033A 9106-0014-033B 9106-0014-033C 9106-0014-033D 9106-0004-013A 9106-0004-013B 9106-0004-013C 9106-0004-013D 9106-0004-005A 9106-0004-005B 9106-0004-005C 9106-0004-005D Method Blank (MB)170256001(9106-0006-005A)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 13 narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170256001 (9106-0006-005A).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 170256007 (9106-0005-010C), 170256016 (9106-0004-013D) and 170256019 (9106-0004-005C) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 14 Qualifier UI U'Reason Data rejected due to high counting uncertainty Data rejected due to interference.

Data rejected due to low abundance.

UI Analyte Bismuth-212 Europium-155 Bismuth-214 Cesium-134 Europium-155 Sample 170256009 170256003 170256009 170256019 170256020 170256008 170256005 170256007 170256008 170256012 170256013 170256019 1201171526 170256018 Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr9O, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 562563 562478 562444 15 Sample ID 170256001 170256002 170256003 170256004 170256005 170256006 170256007 170256008 170256009 170256010 170256011 170256012 170256013 170256014 170256015 170256016 170256017 170256018 170256019 170256020 1201169421 1201169422 1201169423 1201169424 Client ID 9106-0006-005A 9106-0006-005B 9106-0006-005C 9106-0006-005D 9106-0005-O1OA 9106-0005-OIOB 9106-0005-OIOC 9106-0005-OIOD 9106-0014-033A 9106-0014-033B 9106-0014-033C 9106-0014-033D 9106-0004-013A 9106-0004-013B 9106-0004-013C 9106-0004-013D 9106-0004-005A 9106-0004-005B 9106-0004-005C 9106-0004-005D Method Blank (MB)170256002(9106-0006-005B)

Sample Duplicate (DUP)170256002(9106-0006-005B)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170256002 (9106-0006-005B).

16 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery.Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

17 SAMPLE DATA

SUMMARY

18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1160 GEL Work Order: 170256 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 19 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: 9106-0006-005A Project: YANKO 1204 Sample ID: 170256001 Client ID: YANKOO Matrix: SE Vol. Recv.: Collect Date: 08-AUG-06 Receive Date: 25-AUG-06 Collector:

Client Moisture:

15.8%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.966 +/-0.192 Americium-241 U 0.0375 +/-0.0387 Bismuth-212 0.366 +/-0.306 Bismuth-214 0.650 +/-0.135 Cesium-134 U 0.0366 +/-0.0355 Cesium-137 0.0666 +/-0.0355 Cobalt-60 0.104 +/-0.0726 Europium-152 U 0.00636 +/-0.0728 Europium-154 U -0.0788 +/-0.0938 Europium-155 U 0.0672 +1-0.0554 Lead-212 0.871 +/-0.0971 Lead-214 0.727 +/-0.105 Manganese-54 U -0.00916 +/-0.0319 Niobium-94 U 0.0101 +/-0.0244 Potassium-40 11.3 +/-0.986 Radium-226 0.650 +/-0.135 Silver-108m U -0.0067 +/-0.0208 Thallium-208 0.283 +/-0.0618 Rad Gas Flow Proportional Counting 0.0743 0.0329 0.175 0.042 0.0288 0.0236 0.0286 0.0538 0.0718 0.0518 0.0305 0.0379 0.0232 0.0223 0.201 0.042 0.018 0.0212+/-0.192+/-0.0387+/-0.306+/-0.135+/-0.0355+/-0.0355+/-0.0726+/-0.0728+/-0.0938+/-0.0554+/-0.0971+/-0.105+/-0.0319+/-0.0244+/-0.986+/-0.135+/-0.0208+/-0.0618 0.149 0.0658 0.350 0.0839 0.0576 0.0472 0.0573 0.108 0.143 0.104 0.061 0.0757 0.0465 0.0445 0.403 0.0839 0.036 0.0423 0.0298 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1057 563436 1 KSDI 09/07/06 1742 562563 2 GFPC, S90, solid-ALL FSS Strontium-90 U 0.0254 +/-0.0193 0.0126 +/-0.0193 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified 20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005A Proiect: YANKO 1204 Sample ID: 170256001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.21 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005B 170256002 SE 08-AUG-06 25-AUG-06 Client 14.4%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.606 Americium-241 U 0.101 Bismuth-212 0.685 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.435 U 0.0313 0.114 0.436 U -0.0448 U -0.0186 U 0.0423 0.643 0.462 U -0.0167 U 0.00909 11.1 0.435 U -0.00194 0.243-I Af Af A*+/-0.152+/-0.114+/-0.232-/-0.0852-/-0.0286-/-0.0348-/-0.0586-/-0.0525-/-0.0685-/-0.0579-/-0.0623-/-0.0885-/-0.0261-/-0.0195+/-0.983-/-0.0852-/-0.0168-/-0.0457 0.0599 0.0861 0.134 0.0332 0.0238 0.0206 0.0151 0.0416 0.0562 0.0552 0.0268 0.033 0.0174 0.0173 0.179 0.0332 0.0149 0.0176+/-0.152+/-0.114+/-0.232+/-0.0852+/-0.0286+/-0.0348+/-0.0586+/-0.0525+/-0.0685+/-0.0579+/-0.0623+/-0.0885+/-0.0261+/-0.0195+/-0.983+/-0.0852+/-0.0168+/-0.0457 MDA 0.131 0.179 0.290 0.0708 0.0507 0.0438 0.0345 0.0882 0.124 0.114 0.056 0.0696 0.0377 0.0369 0.399 0.0708 0.0317 0.0377 0.0278 Units DF Analyst Date Time Batch Mtd pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1220 563436 1 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00501 +/-0.0149 0.0117 +/-0.0149 KSD1 09/07/06 1742 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005B Project: YANKO 1204 Sample ID: 170256002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005C 170256003 SE 09-AUG-06 25-AUG-06 Client 31.7%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date. Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-15 4 U Europium-155 Ul Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-4 0 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 1.07 0.0251 0.684 0.673 0.0516 0.317 0.821-0.049 0.0883 0.00 1.01 0.828-0.0228-0.0353 12.4 0.673 0.00475 0.382+/-0.284+/-0.0367+/-0.424+/-0.121+/-0.0548+/-0.0544+/-0.0911+/-0.0652+/-0.0913+/-0.0926+/-0.0819+/-0.117+/-0.0296+/-0.0279+1-1.15+/-0.121+/-0.0263+/-0.0567 0.101 0.0332 0.178 0.0445 0.0344 0.0247 0.0294 0.0539 0.0839 0.0506 0.0329 0.0423 0.0238 0.0205 0.189 0.0445 0.0227 0.0242+/-0.284+/-0.0367+/-0.424+/-0.121+/-0.0548+/-0.0544+/-0.0911+/-0.0652+/-0.0913+/-0.0926+/-0.0819+/-0.117+/-0.0296+/-0.0279+1-1.15+/-0.121+/-0.0263+/-0.0567 0.215 0.0683 0.383 0.0947 0.0729 0.0528 0.064 0.114 0.182 0.105 0.0685 0.089 0.0513 0.044 0.431 0.0947 0.0477 0.0515 0.0255 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1221 563436 1 KSDI 09/07/06 1745 562563 2 0.00738 +/-0.0142 0.0107 +/-0.0142 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005C Project: YANK01204 Sample ID: 170256003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 104 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005D 170256004 SE 09-AUG-06 25-AUG-06 Client 28.2%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty Rad Gamma Spec Analysis Ganimna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.197 Americium-241 U 0.0605 +/-0.132 Bismuth-212 0.534 +/-0.328 Bismuth-214 0.594 +1-0.105 Cesium-134 U 0.0478 +/-0.046 Cesium-137 0.103 +/-0.0401 Cobalt-60 0.148 +/-0.0644 Europium-152 U 0.00143 +/-0.0589 Europium-15 4 U 0.0154 +/-0.0766 Europium-155 U 0.0625 +/-0.0643 Lead-212 0.900 +/-0.0831 Lead-214 0.854 +/-0.106 Manganese-54 U -0.013 +/-0.0244 Niobium-94 U 0.0144 +/-0.022 Potassium-40 11.6 +/-0.886 Radium-226 0.594 +1-0.105 Silver-108m U 0.0118 +/-0.0187 Thallium-208 0.310 +/-0.0591 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.000446 +/-0.0198 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0659 0.088 0.168 0.0384 0.0253 0.0181 0.0204 0.0517 0.0653 0.0586 0.0345 0.0372 0.0203 0.0192 0.177 0.0384 0.0169 0.0199+/-0.197+/-0.132+/-0.328+1-0.105+/-0.046+/-0.0401+/-0.0644+/-0.0589+/-0.0766+/-0.0643+/-0.0831+/-0.106+/-0.0244+/-0.022+/-0.886+/-0.105+/-0.0187+/-0.0591 0.143 0.182 0.358 0.0813 0.0537 0.0389 0.045 0.109 0.142 0.121 0.0714 0.078 0.0434 0.0408 0.396 0.0813 0.0357 0.0422 0.0376 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1221 563436 1 KSDI 09/07/06 1740 562563 2 0.0166 +/-0.0198 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005D Project: YANK01204 Sample ID: 170256004 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 50 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-O1OA 170256005 SE 09-AUG-06 25-AUG-06 Client 60.7%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.22 Americium-241 U 0.0503 Bismuth-212 0.628 Bismuth-214 0.834 Cesium-134 UI 0.00 Cesium-137 U 0.0463 Cobalt-60 U 0.077 Europium-152 U 0.00822 Europium-154 U-0.000512 Europium-155 U 0.0659 Lead-212 0.933 Lead-214 0.787 Manganese-54 U -0.0199 Niobium-94 U -0.0359 Potassium-40 20.0 Radium-226 0.834 Silver-108m U -0.00415 Thallium-208 0.347 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00442+/-0.394+/-0.0522+/-0.547+/-0.160+/-0.0832+/-0.0542+/-0.0516+/-0.0958+/-0.129+/-0.115+/-0.111+/-0.146 F/-0.0442 F/-0.0364+/-1.50+/-0.160+/-0.0338+/-0.0918 0.120 0.0424 0.277 0.0633 0.0429 0.0333 0.0472 0.0766 0.0917 0.0674 0.0593 0.0602 0.0342 0.0275 0.288 0.0633 0.0282 0.0332+/-0.394+/-0.0522+/-0.547+/-0.160+/-0.0832+/-0.0542+/-0.0516+/-0.0958+/-0.129+/-0.115+/-0.111+/-0.146+/-0.0442+/-0.0364+/-1.50+/-0.160+/-0.0338+/-0.0918 0.255 0.0872 0.584 0.133 0.0903 0.0703 0.100 0.160 0.199 0.139 0.122 0.125 0.0725 0.0583 0.634 0.133 0.0591 0.0698 0.0274 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1221 563436 1 KSDI 09/07/06 1745 562563 2+/-0.0146 0.0116 +/-0.0146 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010A Proiect: YANK01204 Sample ID: 170256005 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-OIOB 170256006 SE 09-AUG-06 25-AUG-06 Client 61.3%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-JFSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-2 4 1 U -Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U -1.10-0.00576 0.760 0.576 0.0332 0.0908 0.115 0.00833-0.0828 0.0871 1.08 0.812 0.0145 0.00876 19.3 0.576-0.00887 0.282+/-0.245+/-0.0366+/-0.351+/-0.139+/-0.0438+/-0.0468+/-0.0522+/-0.068+/-0.106+/-0.0591+/-0.0778+/-0.0928+/-0.0313+/-0.0271+/-1.35+/-0.139+/-0.0232+/-0.0641 0.0778 0.0263 0.189 0.0442 0.0314 0.0231 0.0225 0.0546 0.0808 0.0504 0.0306 0.0385 0.0262 0.0226 0.236 0.0442 0.0191 0.0224+/-0.245+/-0.0366+/-0.351+/-0.139+/-0.0438+/-0.0468+/-0.0522+/-0.068+/-0.106+/-0.0591+/-0.0778+/-0.0928+/-0.0313+/-0.0271+/-1.35+/-0.139+/-0.0232+/-0.0641 0.168 0.0543 0.402 0.0936 0.0665 0.0493 0.0499 0.115 0.175 0.104 0.0636 0.081 0.0557 0.0479 0.521 0.0936 0.0403 0.0475 0.0368 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1221 563436 1 KSDI 09/07/06 1746 562563 2-0.00561 +/-0.0185 0.0162 +/-0.0185 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description LXM2 08/27/06 1545 562444 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010B Project: YANK01204 Sample ID: 170256006 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 89 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-OIOC 170256007 SE 09-AUG-06 25-AUG-06 Client 49.2%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 +/-0.196 Americium-241 U 0.00111 +/-0.108 Bismuth-212 0.539 +/-0.392 Bismuth-214 0.626 +/-0.10I Cesium- 134 UI 0.00 +/-0.0318 Cesium-137 0.192 +/-0.0408 Cobalt-60 0.522 +/-0.0639 Europium-152 U -0.0379 +/-0.0596 Europium-154 U -0.0318 +/-0.0732 Europium-155 U 0.0641 +/-0.0925 Lead-212 1.14 +/-0.0696 Lead-214 0.753 +/-0.0911 Manganese-54 U 0.0134 +/-0.0217 Niobium-94 U 0.0073 +/-0.0216 Potassium-40 17.9 +/-1.02 Radium-226 0.626 +/-0.101 Silver-108m U 0.00496 +/-0.0191 Thallium-208 0.354 +/-0.0504 Rad Gas Flow Proportional Counting 0.0698 0.0862 0.142 0.0371 0.025 0.0197 0.0211 0.0464 0.0585 0.0488 0.0264 0.0337 0.0193 0.0181 0.190 0.0371 0.0165 0.0183+/-0.196+/-0.108+/-0.392+/-0.101+/-0.0318+/-0.0408+/-0.0639+/-0.0596+/-0.0732+/-0.0925+/-0.0696+/-0.0911+/-0.0217+/-0.0216+/-1.02+/-0.101+/-0.0191+/-0.0504 0.148 0.177 0.300 0.0775 0.0524 0.0414 0.0453 0.0966 0.126 0.100 0.0544 0.070 0.0408 0.038 0.412 0.0775 0.0344 0.0384 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/05/06 2124 563436 1 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00471 +/-0.0144 0.0114 +/-0.0145 0.027 KSDI 09/07/06 1758 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOC Proiect: YANK01204 Sample ID: 170256007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-01OD 170256008 SE 09-AUG-06 25-AUG-06 Client 58.1%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.920 +/-0.431 Americium-241 U 0.159 +/-0.0868 Bismuth-212 0.975 +/-0.615 Bismuth-214 Ul 0.00 +/-0.170 Cesium-134 UI 0.00 +/-0.0619 Cesium-137 0.630 +/-0.105 Cobalt-60 2.24 +/-0.161 Europium-152 U 0.0801 +/-0.100 Europium-154 U 0.159 +/-0.180 Europium-155 U 0.0923 +/-0.117 Lead-212 1.10 +/-0.108 Lead-214 0.707 +/-0.194 Manganese-54 U 0.0291 +/-0.050 Niobium-94 U 0.0114 +/-0.0446 Potassium-40 16.4 +/-1.57 Radium-226 0.761 +/-0.170 Silver-108m U 0.00643 +/-0.0377 Thallium-208 0.396 +/-0.103 Rad Gas Flow Proportional Counting 0.163 0.0423 0.310 0.126 0.0563 0.037 0.0361 0.0874 0.124 0.0649 0.0414 0.0578 0.0419 0.0367 0.341 0.0744 0.0316 0.0362+/-0.431+/-0.0868+/-0.615+/-0.170+/-0.0619+/-0.105+/-0.161+/-0. 100+/-0.180+/-0.117+/-0.108+/-0.194+1-0.050+/-0.0446+/-1.57+/-0.170+/-0.0377+/-0.103 0.345 0.0871 0.654 0.259 0.118 0.0784 0.0793 0.182 0.267 0.134 0.086 0.121 0.0886 0.0774 0.753 0.156 0.0662 0.0763 0.0315 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1222 563436 1 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0219 +/-0.0196 0.0135 +/-0.0196 KSDI 09/07/06 1805 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010D Project: YANK01204 Sample ID: 170256008 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr9O, solid-ALL FSS 97 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033A 170256009 SE 11-AUG-06 25-AUG-06 Client 26.2%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 Americium-241 U 0.0199 Bismuth-212 UI 0.00 Bismuth-214 0.920 Cesium-134 U 0.0188 Cesium-137 0.709 Cobalt-60 0.697 Europium-152 U -0.0119 Europium-154 U 0.0763 Europium-155 UI 0.00 -Lead-212 1.13 Lead-214 1.04 Manganese-54 U -0.0049 Niobium-94 U 0.014 Potassium-40 14.3 Radium-226 0.920 Silver-108m U3.080E-05 Thallium-208 0.405 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 0.0366+/-0.272+/-0.0632+/-0.484+/-0.139+/-0.0338+/-0.0983+/-0.0935+/-0.0643+/-0.0741+/-0.0951+/-0.134+1-0.151+/-0.0275+/-0.0236+/--1.30+/-0.139 F/-0.0263+/-0.066 0.0796 0.0541 0.171 0.0421 0.0298 0.0246 0.0267 0.0538 0.0675 0.052 0.0457 0.0416 0.023 0.0211 0.185 0.0421 0.0202 0.0235+/-0.272+/-0.0632+/-0.484+/-0.139+/-0.0338+/-0.0983+/-0.0935+/-0.0643+/-0.0741+/-0.0951+/-0.134+1-0.151+/-0.0275+/-0.0236+/-1.30+/-0.139+/-0.0263+/-0.066 0.171 0.112 0.363 0.089 0.0628 0.0519 0.0577 0.113 0.147 0.108 0.0938 0.0871 0.049 0.0446 0.412 0.089 0.0424 0.0495 0.0291 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1223 563436 1 KSD1 09/07/06 1807 562563 2+/-0.0205 0.0124 +/-0.0205 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033A Project: YANKO 1204 Sample ID: 170256009 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90. solid-ALL FSS 99 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033B 170256010 SE 11-AUG-06 25-AUG-06 Client 16.3%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty

'LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.272 Americium-241 U 0.037 +/-0.0519 Bismuth-212 0.897 +/-0.563 Bismuth-214 0.681 +/-0.143 Cesium-134 U 0.062 +/-0.0748 Cesium-137 0.862 +/-0.117 Cobalt-60 0.944 +/-0.113 Europium-152 U 0.00733 +/-0.118 Europium-154 U 0.00812 +1-0.115 Europium-155 U 0.0592 +/-0.0677 Lead-212 0.896 +/-0.109 Lead-214 0.773 +/-0.141 Manganese-54 U -0.0465 +/-0.0487 Niobium-94 U 0.00334 +/-0.0333 Potassium-40 11.6 +/-1.25 Radium-226 0.681 +/-0.143 Silver-108m U -0.00313 +/-0.0324 Thallium-208 0.278 +/-0.0682 Rad Gas Flow Proportional Counting 0.113 0.0353 0.237 0.057 0.0371 0.0301 0.0281 0.0695 0.0959 0.0595 0.0377 0.0491 0.032 0.029 0.247 0.057 0.0274 0.0296+/-0.272+/-0.0519+/-0.563+/-0.143+/-0.0748+/-0.117+/-0.113+/-0.118+1-0.115+/-0.0677+/-0.109+/-0.141+/-0.0487+/-0.0333+/-1.25+/-0.143+/-0.0324+/-0.0682 0.225 0.0705 0.473 0.114 0.0742 0.0601 0.0562 0.139 0.192 0.119 0.0754 0.0981 0.0639 0.0579 0.494 0.114 0.0548 0.0592 0.0268 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1559 563436 1 GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.00794 +/-0.015 0.0113 +/-0.015 KSD1 09/07/06 1807 562563 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 Analyst Date Time Prep Batch LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033B Project: YANK01204 Sample ID: 170256010 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25/-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: 9106-0014-033C Project: YANK01204 Sample ID: 170256011 Client ID: YANKOOI Matrix: SE Vol. Recv.: Collect Date: 1I-AUG-06 Receive Date: 25-AUG-06 Collector:

Client Moisture:

14.2%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium- 134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.841 0.028 0.476 0.628 0.0398 0.609 0.916-0.0803-0.0175 0.0335 0.710 0.810-0.0149-0.00772 11.0 0.628 0.0295 0.237+/-0.277+/-0.048+/-0.345+/-0.128+/-0.0385+/-0.0698+/-0.0989+/-0.0732+/-0.0895+/-0.0642+/-0.0819+/-0.110+/-0.0338+/-0.0304+/-1.00+/-0.128+/-0.0254+/-0.0761 0.100 0.0331 0.223 0.0439 0.0344 0.0277 0.0255 0.0581 0.0738 0.0553 0.0392 0.0428 0.0272 0.0254 0.220 0.0439 0.0239 0.0244+/-0.277+/-0.048+/-0.345+/-0.128+/-0.0385+/-0.0698+/-0.0989+/-0.0732+/-0.0895+/-0.0642+/-0.0819+/-0.110+/-0.0338+/-0.0304+/-1.00+/-0.128+/-0.0254+/-0.0761 0.212 0.068 0.468 0.0928 0.0721 0.0581 0.0552 0.121 0.159 0.114 0.0808 0.0895 0.0575 0.0533 0.484 0.0928 0.0499 0.0513 0.0359 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1829 563436 1 KSDI 09/07/06 1842 562563 2-0.0326 +/-0.013 0.0158 +/-0.013 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033C Project: YANK01204 Sample ID: 170256011 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 90 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033D 170256012 SE S11-AUG-06 25-AUG-06 Client 11.9%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U -Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.800-0.00757 0.514 0.496 0.00 0.240 0.329-0.0221-0.0277 0.0409 0.618 0.582 0.0209 0.0124 10.8 0.496-0.00363 0.222+/-0.169+/-0.0849+/-0.239+/-0.079+/-0.0333+/-0.0466+/-0.0616+/-0.047+/-0.0651+/-0.050+/-0.0549+/-0.0773+/-0.0191+/-0.0174+/-0.796+/-0.079+/-0.0168+/-0.040 0.0584 0.0733 0.125 0.0289 0.0215 0.0172 0.0159 0.0418 0.0444 0.0464 0.0246 0.0304 0.0165 0.0157 0.144 0.0289 0.0148 0.0156+/-0.169+/-0.0849+/-0.239+/-0.079+/-0.0333+/-0.0466+/-0.0616+/-0.047+/-0.0651+/-0.050+/-0.0549+/-0.0773+/-0.0191+/-0.0174+/-0.796+/-0.079+/-0.0168+/-0.040 0.125 0.151 0.265 0.0614 0.0454 0.0365 0.0349 0.0875 0.0974 0.0959 0.0511 0.0635 0.0352 0.0331 0.320 0.0614 0.0312 0.033 0.0276 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g.pCi/g pCi/g pCi/g MJHI 09/05/060531 563436 1 KSDI 09/07/06 1842 562563 2 0.020 +/-0.0174 0.0117 +/-0.0174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033D Proiect: YANK01204 Sample ID: 170256012 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013A 170256013 SE 09-AUG-06 25-AUG-06 Client 17.1%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.15 Americium-241 U 0.0596 Bismuth-212 0.731 Bismuth-214 0.959 Cesium-134 UI 0.00 Cesium-137 U -0.00113 Cobalt-60 U -0.00569 Europium-152 U -0.0275 Europium-154 U -0.0292 Europium-155 U 0.0375 d Lead-212 1.19 d Lead-214 1.08 Manganese-54 U 0.0199 Niobium-94 U -6.020E- d+/-0.162/-0.0865+/-0.295/-0.0845+/-0.0287+/-0.0196-/-0.0174-/-0.0539-/-0.0495-/-0.0594-/-0.0671+/-0.090-/-0.0202-/-0.0164+/-0.771-/-0.0845-/-0.0152-/-0.0539 0.0511 0.0665 0.115 0.0284 0.0195 0.0162 0.0139 0.0402 0.0385 0.0534 0.0261 0.0305 0.0165 0.0143 0.130 0.0284 0.0128 0.0142+/-0.162+/-0.0865+/-0.295+/-0.0845+/-0.0287+/-0.0196+/-0.0174+/-0.0539+/-0.0495+/-0.0594+/-0.0671+/-0.090+/-0.0202+/-0.0164+/-0.771+/-0.0845+/-0.0152+/-0.0539 0.109 0.136 0.242 0.0597 0.041 0.034 0.0301 0.0837 0.0835 0.110 0.0537 0.0634 0.0347 0.030 0.283 0.0597 0.0268 0.030 0.0304 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1830 563436 1 Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting 05 14.3 0.959 0.00566 0.423 H H H GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00331 +/-0.0151 0.0131 +1-0.0151 KSDI 09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: 9106-0004-013A 170256013 Project: Client ID: Vol. Recv.: YANKO 1204 YANK00I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certiricateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013B 170256014 SE 09-AUG-06 25-AUG-06 Client 19.6%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U -Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 1.23 0.0581 0.606 0.990 0.0447 0.0831 0.196 0.0248 0.0401 0.067 1.32 0.989 0.00696 0.00306 9.89 0.990-0.017 0.456+/-0.302+/-0.0456+/-0.361+/-0.154+/-0.0383+/-0.037+/-0.0645+/-0.116+/-0.106+/-0.0826+/-0.136+/-0.153+/-0.0306+/-0.0256+/-0.996+/-0.154+/-0.0253+/-0.084 0.0948 0.0383 0.199 0.046 0.033 0.0286 0.0258 0.061 0.0809 0.0584 0.0337 0.0431 0.0262 0.0228 0.207 0.046 0.0211 0.0253+/-0.302+/-0.0456+/-0.361+/-0.154+/-0.0383+/-0.037+/-0.0645+/-0.116+/-0.106+/-0.0826+/-0.136+/-0.153+/-0.0306+/-0.0256+/-0.996+/-0.154+/-0.0253+/-0.084 0.190 0.0765 0.399 0.0919 0.066 0.0571 0.0515 0.122 0.162 0.117 0.0674 0.0862 0.0523 0.0455 0.414 0.0919 0.0422 0.0505 0.0316 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 09/01/062110 563436 1 KSDI 09/07/06 1843 562563 2 0.00221 +/-0.0172 0.0143 +/-0.0172 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013B Project: YANKO 1204 Sample ID: 170256014 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certificateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013C 170256015 SE 09-AUG-06 25-AUG-06 Client 17.3%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 Americium-241 U -0.00337 Bismuth-212 0.808 Bismuth-214 0.614 Cesium-134 U 0.0481 Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.0789 0.074-0.0203-0.0129 0.0479 0.903 0.651-0.0163-0.022 12.9 0.614 0.00256 0.248 q q q q+/-0.236+/-0.0367+/-0.311+/-0.118+/-0.0502+/-0.0569 F/-0.0564+/-0.0622+/-0.0828+/-0.0527 F/-0.0714+/-0.103+/-0.0298+/-0.0284+/-1.11+/-0.118+/-0.0199+/-0.0569 0.0703 0.034 0.157 0.0422 0.033 0.0226 0.0239 0.0547 0.0688 0.0529 0.0332 0.0431 0.0235 0.0226 0.250 0.0422 0.0177 0.0239+/-0.236+/-0.0367+/-0.311+/-0.118+/-0.0502+/-0.0569+/-0.0564+/-0.0622+/-0.0828+/-0.0527+/-0.0714+/-0.103+/-0.0298+/-0.0284+/-1.11+/-0.118+/-0.0199+/-0.0569 0.154 0.0701 0.341 0.0899 0.0699 0.0484 0.0531 0.115 0.152 0.109 0.069 0.0904 0.0506 0.0481 0.553 0.0899 0.0378 0.0508 0.0289 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 2118 563436 1 KSDI 09/07/06 1845 562563 2 0.00157 +/-0.0143 0.0123 +/-0.0143 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013C Project: YANK01204 Sample ID: 170256015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 98 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013D 170256016 SE 09-AUG-06 25-AUG-06 Client 25.9%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-5 4 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 1.03 0.0216 0.420 0.689 0.0488 0.170 0.566 0.0265 0.0628 0.0541 0.958 0.784 0.00917 0.0056 12.6 0.689 0.00656 0.314+/-0.160+/-0.0981+/-0.350+/-0.0898+/-0.0307+/-0.0491+/-0.0694+/-0.0524+/-0.0639+/-0.0561+/-0.0653+/-0.0896+/-0.0221+/-0.019+/-0.931+/-0.0898+/-0.0175+/-0.0426 0.0664 0.0845 0.142 0.0339 0.0247 0.019 0.0198 0.0453 0.0591 0.0528 0.0265 0.0297 0.019 0.0164 0.166 0.0339 0.0151 0.0189+/-0.160+/-0.0981+/-0.350+/-0.0898+/-0.0307+/-0.0491+/-0.0694+/-0.0524+/-0.0639+/-0.0561+/-0.0653+/-0.0896+/-0.0221+/-0.019+/-0.931+/-0.0898+/-0.0175+/-0.0426 0.142 0.174 0.301 0.0715 0.0519 0.0402 0.0431 0.0946 0.127 0.109 0.055 0.0623 0.0403 0.0347 0.367 0.0715 0.0318 0.0398 0.0265 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJIHl 09/05/06 0521 563436 1 KSDI 09/07/06 1846 562563 2 0.00738 +/-0.0147 0.0112 +/-0.0147 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description LXM2 08/27/06 1545 562444 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013D Proiect: YANKO1204 Sample ID: 170256016 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 106 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005A 170256017 SE 09-AUG-06 25-AUG-06 Client 17.9%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.975 +/-0.164 Americium-241 U 0.0504 +/-0.0306 Bismuth-212 0.804 +/-0.393 Bismuth-214 0.647 +/-0.112 Cesium-134 U 0.0288 +/-0.0288 Cesium-137 0.249 +/-0.0491 Cobalt-60 0.682 +/-0.0884 Europium-152 U 0.0893 +/-0.0683 Europium-154 U 0.0167 +/-0.0707 Europium-155 U 0.00619 +/-0.0524 Lead-212 0.912 +/-0.0658 Lead-214 0.747 +/-0.0939 Manganese-54 U 0.0235 +/-0.0494 Niobium-94 U -0.00608 +/-0.0244 Potassium-40 10.5 +/-0.910 Radium-226 0.647 +/-0.112 Silver-108m U 0.00189 +/-0.0202 Thallium-208 0.322 +/-0.0462 Rad Gas Flow Proportional Counting 0.0814 0.030 0.165 0.0371 0.0271 0.0255 0.0206 0.0526 0.0611 0.0476 0.0281 0.036 0.0228 0.0201 0.155 0.0371 0.0178 0.0209+/-0.164+/-0.0306+/-0.393+/-0.112+/-0.0288+/-0.0491+/-0.0884+/-0.0683+/-0.0707+/-0.0524+/-0.0658+/-0.0939+/-0.0494+/-0.0244+/-0.910+/-0.112+/-0.0202+/-0.0462 0.174 0.0616 0.351 0.0787 0.0574 0.0537 0.0453 0.110 0.134 0.0982 0.0584 0.0755 0.0486 0.0426 0.351 0.0787 0.0376 0.0442 0.0286 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 2119 563436 1 GFPC, SO9O, solid-ALL FSS Strontium-90 U -0.00262 +/-0.0137 0.012 +/-0.0137 KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Qualifier Result Uncertainty 9106-0004-005A 170256017 LC TPU MDA Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Units DF Analyst Date Time Batch Mtd Parameter'Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 92 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005B 170256018 SE 1 0-AUG-06 25-AUG-06 Client 14%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.787 +/-0.187 Americium-241 U 0.0759 +/-0.0649 Bismuth-212 0.403 +/-0.233 Bismuth-214 0.636 +/-0.108 Cesium- 134 U 0.0378 +/-0.0274 Cesium-137 0.181 +/-0.0421 Cobalt-60 0.710 +/-0.0716 Europium-152 U 0.0183 +/-0.0466 Europium-154 U 0.0204 +/-0.0516 Europium-155 U1 0.00 +/-0.0804 Lead-212 0.722 +/-0.086 Lead-214 0.832 +/-0.115 Manganese-54 U 0.0204 +/-0.0232 Niobium-94 U 0.0129 +/-0.0173 Potassium-40 9.30 +/-0.895 Radium-226 0.636 +/-0.108 Silver-108m U 0.0081 +/-0.0194 Thallium-208 0.299 +/-0.0505 Rad Gas Flow Proportional Counting 0.0725 0.0382 0.139 0.0306 0.0229 0.019 0.0155 0.0421 0.0449 0.0458 0.0317 0.0288 0.0192 0.0161 0.130 0.0306 0.0154 0.0157+/-0.187+/-0.0649+/-0.233+/-0.108+/-0.0274+/-0.0421+/-0.0716+/-0.0466+/-0.0516+/-0.0804+/-0.086+1-0.115+/-0.0232+/-0.0173+/-0.895+/-0.108+/-0.0194+/-0.0505 0.153 0.0789 0.294 0.0647 0.0482 0.040 0.034 0.0881 0.0982 0.0944 0.0651 0.0605 0.0406 0.0339 0.291 0.0647 0.0324 0.0332 0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/02/06 1713 563436 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0109 +/-0.0167 0.0123 +/-0.0167 KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005B Project: YANKO1204 Sample ID: 170256018 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 95 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis.....T .....i --Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005C 170256019 SE 10-AUG-06 25-AUG-06 Client 24.6%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 0.810 U 0.0147 0.365 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 Europium-152 U -Europium-154 U Europium-155 U1 Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.623 0.00 0.113 0.268 0.00617-0.0248 0.00 0.840 0.686 0.00306 0.0053 10.2 0.623-0.0071 0.288+/-0.116+/-0.0176+/-0.171+/-0.0633+/-0.0297+/-0.0242+/-0.0379+/-0.0317+/-0.0417+/-0.0407+/-0.0404+1-0.0505+/-0.0143+/-0.013+1-0.535+/-0.0633+/-0.0113+/-0.031 0.0431 0.0169 0.099 0.0212 0.0166 0.0124 0.012 0.0284 0.0337 0.0265 0.0162 0.0197 0.0127 0.0112 0.0857 0.0212 0.00971 0.0115+/-0.116+/-0.0176+/-0.171+/-0.0633+/-0.0297+/-0.0242+/-0.0379+/-0.0317+/-0.0417+/-0.0407+/-0.0404+1-0.0505+/-0.0143+/-0.013+/-0.535+/-0.0633+/-0.0113+/-0.031 0.090 0.0345 0.206 0.044 0.0343 0.0257 0.0254 0.0585 0.0714 0.054 0.0332 0.0406 0.0265 0.0232 0.186 0.044 0.0201 0.0239 0.0284 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/05/06 2143 563436 1 KSDI 09/07/06 1857 562563 2 0.0082 +/-0.0158 0.012 +/-0.0158 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005C Project: YANKO 1204 Sample ID: 170256019 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005D 170256020 SE 10-AUG-06 25-AUG-06 Client 19.1%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.995 +/-0.411 Americium-241 U 0.0557 +/-0.0479 Bismuth-212 0.635 +/-0.589 Bismuth-214 0.760 +/-0.165 Cesium-134 U 0.0627 +/-0.0504 Cesium-137 0.503 +/-0.0894 Cobalt-60 1.72 +/-0.132 Europium-152 U 0.00265 +/-0.0988 Europium-154 U 0.0538 +/-0.114 Europium-155 UI 0.00 +/-0.119 Lead-212 1.09 +/-0.126 Lead-214 0.802 +/-0.135 Manganese-54 U 0.0185 +/-0.0434 Niobium-94 U -0.0168 +/-0.0366 Potassium-40 10.7 +/- 1. 11 Radium-226 0.760 +/-0.165 Silver-108m U -0.021 +/-0.0301 Thallium-208 0.343 +/-0.0887 Rad Gas Flow Proportional Counting 0.146 0.0365 0.261 0.0601 0.0463 0.0338 0.0307 0.0745 0.0996 0.0591 0.0386 0.0517 0.0383 0.0309 0.276 0.0601 0.0247 0.0298+/-0.411+/-0.0479+/-0.589+/-0.165+/-0.0504+/-0.0894+/-0.132+/-0.0988+/-0.114+/-0.119+/-0.126+/-0.135+/-0.0434+/-0.0366+/-1.11+/-0.165+/-0.0301+/-0.0887 0.291 0.0729 0.521 0.120 0.0926 0.0676 0.0614 0.149 0.199 0.118 0.0772 0.103 0.0766 0.0618 0.551 0.120 0.0494 0.0595 0.0299 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/02/06 1725 563436 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00322 +/-0.0146 0.0127 +/-0.0146 KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005D Project: YANKO 1204 Sample ID: 170256020 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.59 QUALITY CONTROL DATA 60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd RePort Date: September 8, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

170256 V"IV4NA Q I I rC fh.1. 1DnfO/uvd-o/ 1D.- A I I* an.n~a..cins.. .am.pc e~ Q a., L113 fl 1.z, nh/i ,U fa1ge sll3 IafLe m 1 Rad Gamma Spec Batch 563436 U QC1201171526 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 170256001 DUP 0.966 Uncert: +/-0.192 TPU: +/-0.192 U 0.0375 Uncert: +/-0.0387 TPU: +/-0.0387 0.366 Uncert: +/-0.306 TPU: +/-0.306 0.650 Uncert: +/-0.135 TPU: +/-0.135 U 0.0366 Uncert: +/-0.0355 TPU: +/-0.0355 0.0666 Uncert: +/-0.0355 TPU: +/-0.0355 0.104 Uncert: +/-0.0726 TPU: +/-0.0726 U 0.00636 Uncert: +/-0.0728 TPU: +/-0.0728 U -0.0788 Uncert: +/-0.0938 TPU: +/-0.0938 U 0.0672 Uncert: +/-0.0554 TPU: +/-0.0554 0.871 Uncert: +/-0.0971 TPU: +/-0.0971 0.727 Uncert: +/-0.105 TPU: +/-0.105 U -0.00916 Uncert: +/-0.0319 TPU: +/-0.0319 U 0.0101 Uncert: +/-0.0244 TPU: +/-0.0244 1.01+/-0.200+/-0.200 U 0.0258+/-0.075-/-0.075 0.592+/-0.276+/-0.276 0.690+/-0.0955+/-0.0955 UI 0.00+/-0.035+/-0.035 0.0611+/-0.0415+/-0.0415 0.159+/-0.0325+/-0.0325 U -0.00858+/-0.0624+/-0.0624 U 0.00919+/-0.0602+/-0.0602 U 0.0817+/-0.0557+/-0.0557 0.847+/-0.0867+/-0.0867 0.699+/-0.102+/-0.102 U -0.00665+/-0.0225+/-0.0225 U -0.00339+/-0.0176+/-0.0176 pCi/g 4 pCi/g 37 pCi/g 47 pCi/g 6 pCi/g 56 pCi/g 9 pCi/g 41 pCi/g 1350 pCi/g 253 pCi/g 20 pCi/g 3 pCi/g 4 pCi/g 32 pCi/g 402 (0%- 100%) MJHI 09/02/06 17:26 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0%- 100%)(0% -100%)61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 2 of 5 Parmname Rad Gamma Spec Batch 563436 Potassium-40 Radium-226 NOM Sample Qual OC Units RPD%REC% Ran2e Anist Date Time 11.3 Uncert: +/-0.986 TPU: +/-0.986 0.650 Uncert: +/-0.135 TPU: +/-0.135 U -0.0067 Uncert: +/-0.0208 TPU: +/-0.0208 0.283 Uncert: +/-0.0618 TPU: +/-0.0618 Silver-108m Thallium-208 QC1201171527 Actinium-228 Americium-24 I Bismuth-212 LCS Bismuth-214 Cesium-134 Cesium- 137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.58 Uncert: TPU: 14.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: 11.7+/-1.03+/-1.03 0.690+/-0.0955+/-0.0955 U 0.000104+/-0.018+/-0.018 0.283+/-0.048+/-0.048 U 0.254+/-0.565+/-0.565 24.1+/-1.28+/-1 .28 U 0.575+/-0.944+/-0.944 U 0.0248+/-0.213+/-0.213 U 0.00032+/-0.147+/-0.147 9.84+/-0.487+/-0.487 14.7+/-0.660+/-0.660 U 0.125+/-0.292+/-0.292 U 0.0779+/-0.277+/-0.277 U -0.0876+/-0.277+/-0.277 U 0.0524+/-0.155+/-0.155 U -0.103+/-0.212 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/03/06 22:31 pCi/g 3 pCi/g 6 pCi/g 206 pCi/g 0 103 (75%-125%)

(0%-20%)(0%- 100%)(0%- 100%)(0%- 100%)103 (75%-125%)

101 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 3 of 5 Parmname NOM SamDle Oual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 563436 TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QCI201171525 Actinium-228 Americium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.212 U 0.0306+/-0.135+/-0.135 U -0.0513+/-0.115+1-0.115 U 0.769+/-1.10+/-1.10 U 0.0248+/-0.213+/-0.213 U 0.0782+1-0.105+1-0.105 U 0.180+/-0.177+/-0.177 U 0.0216+/-0.0479+/-0.0479 U -0.0654+/-0.0396+/-0.0396 U 0.110+/-0.0705+/-0.0705 U 0.00843+/-0.0317+/-0.0317 U -0.00203+/-0.012+/-0.012 U -0.00757+/-0.0117+/-0.0117 U -0.00589+/-0.0128+/-0.0128 U -0.0169+/-0.0308+/-0.0308 U 0.00802+/-0.0305+/-0.0305 U -0.00342 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

09/02/06 17:16 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 563436 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassiurn-40 Radium-226 Silver- 108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0294+/-0.0294 U 0.0151+/-0.028+/-0.028 U 0.00738+/-0.0252+/-0.0252 U 0.0127+/-0.0111+/-0.0111 U -0.00293+/-0.012+/-0.012 U 0.112+/-0.173+/-0.173 U 0.00843+/-0.0317+/-0.0317 U 0.00354+/-0.0115+/-0.0115 U -0.011+/-0.0157+/-0.0157 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Rad Gas Flow Batch 562563 QCI201169422 170256002 DUP Strontiurn-90 QC1201169424 LCS Strontium-90 QC1201169421 MB Strontium-90 QC1201169423 170256002 MS Strontium-90 U 0.00501 Uncert: +/-0.0149 TPU: +/-0.0149 U 0.00534+/-0.0155+/-0.0155 1.57+/-0.140+/-0.147 pCi/g 0 (0%- 100%) KSDI 09/07/06 18:59 1.74 Uncert: TPU: Uncert: TPU: 1.74 U Uncert: TPU: U 0.0172+/-0.0185+/-0.0185 pCi/g pCi/g pCi/g 90 (75%-125%)

09/07/06 19:16 09/07/06 18:59 09/07/06 19:16 0.00501+/-0.0149+/-0.0149 1.32+/-0.124+/-0.130 76 (75%-125%)

Notes: The Qualifiers in this report are defined as follows: 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

170256 Page 5 of 5 Parmname NOM Sample Qual* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike con R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concen Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5 h Preparation or preservation holding time was exceeded QC Units RPD% REC% Range Anist Date Time centration by 4X or more ning this qualifier X the RL N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of+/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.65 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (5 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 014 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0014-002FS Sample

Description:

Comparison of split samples collected from sample measurement location #02 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0014-002F, thE comparison sample was 9106-0014-002FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (YIN)Value Error Range Value Error Ratio Cs-137 3.6 1E-03 7.80E-03 0 NONE -7.24E-02 1.22E-02 20.06 N/A Co-60 2.52E-03 7.OOE-03 0 NONE -1.04E-01 2.10E-02 41.27 N/A K-40 1.02E+01 3.07E-01 33 0.75- 1.33 9.30E+00 4.56E-01 0.91 Y Comments/Corrective Actions: Inconsideration of Cs-137 and Table is provided to show acceptance criteria used Co-60 results, guidance for agreement ranges, obtained from to assess split samples.USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of Resolution Agreement Range acceptability for such rations cannot be made. Since K-40 was 4 7 0.50 2.00 found to be present at an acceptable level of agreement, no 8 15 0.60 1.66 further action is warranted.

16 50 0.75 1.33 51 200 0.80 1.25> 200 0.85 1.18 Performed By: Date: Reviewed By. ate: At-V"/4 WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation V/Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 014 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0014-008FS Sample

Description:

Comparison of split samples collected from sample measurement location #08 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0014-008F, the comparison sample was 9106-0014-008FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 9.66E-02 2.43E-02 4 NONE -3.82E-02 2.16E-02 0.40 N/A Co-60 1.60E-01 2.83E-02 6 0.5 -2.00 5.29E-02 2.21E-02 0.33 N K-40 1.36E+01 6.60E-01 21 0.75- 1.33 1.19E+01 5.10E-01 0.88 Y Comments/Corrective Actions: In consideration of the Cs-137 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. Since Co-60 has a likelyhood to be present in the sample matrix in particulate form, one would not neccassarily expect it to be homogenuously mixed from processing of the sample-split aliqot. Further, since K-40 was found to be present at an acceptable level of agreement, no further action is warranted.

Table is provided to show acceptance criteria used to assess split samples.Resolution I Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By:@2, N'"O WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 014 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0014-027FS Sample

Description:

Comparison of split samples collected from sample measurement location #27 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0014-027F, the comparison sample was 9106-0014-027FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 1.66E-01 2.01E-02 8 0.6- 1.66 1.15E-01 1.67E-02 0.69 Y Co-60 4.69E-01 2.81E-02 17 0.75- 1.33 3.94E-01 2.91E-02 0.84 Y K-40 1.07E+01 5.00E-01 21 0.75- 1.33 1.05E+01 4.64E-01 0.98 Y Comments/Corrective Actions: Cs-137, Co-60 and K-40 were Table is provided to show acceptance criteria used found to be present at an acceptable level of agreement, to assess split samples.Therefore, no further action is warranted.

Resolution Agreement Range 4 7 0.50 2.00 8 15 0.60 1.66 16 50 0.75 1.33 51 200 0.80 1.25> 200 0.85 1.18 Performed By: Date: Reviewed By: Date: 62d0WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation y Page l of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 014 Survey Discharge Canal#:9106 Unit #: Unit Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0014-028FS Sample

Description:

Comparison of split samples collected from sample measurement location #28 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0014-028F the comparison sample was 9106-0014-028FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 8.72E-02 2.44E-02 4 0.50 2.00 1.20E-01 3.20E-02 1.38 Y Co-60 1.86E-01 3.02E-02 6 0.50 2.00 1.99E-01 2.85E-02 1.07 Y K-40 8.46E+00 5.30E-01 16 0.75 1.33 1.04E+01 5.75E-01 1.23 Y 4. 4 4. 1 I 4 .4 I--I .1 -I Comments/Corrective Actions: Cs-137, Co-60 and K-40 were found to be vresent at an acceotable level of agreement.

Table is provided to show acceptance criteria used to assess split samples.Therefore, no further action is warranted.

Resolution I Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By: 45eZAwlýWPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation (Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 014 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0014-041FS Sample

Description:

Comparison of split samples collected from sample measurement location #41 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0014-041F, the comparison sample was 9106-0014-041FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 4.76E-02 1.37E-02 3 NONE -7.24E-02 1.22E-02 1.52 N/A Co-60 1.47E-01 2.1OE-02 7 0.5 -2.00 1.04E-01 2.1OE-02 0.71 Y K-40 9.76E+00 3.88E-01 25 0.75- 1.33 9.30E+00 4.56E-01 0.95 Y Comments/Corrective Actions: In consideration of Cs-137 Table is provided to show acceptance criteria used results, guidance for agreement ranges, obtained from USNRC to assess split samples.Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such Resolution Agreement Range rations cannot be made. Since Co-60 and K-40 was found to be 4 7 0.50 2.00 present at an acceptable level of agreement, no further action is 8 15 0.60 1.66 warranted.

16 50 0.75 1.33 51 200 0.80 1.25> 200 0.85 1.18 Performed By: Date: Reviewed By: Date: 65~~2~~ ~~ -46/ ~ !- 4 x//~-WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation 6 Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2c Preliminary Data Form (2 Pages)

Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B, Rev. C'Health Physics Procedure GPP-GGGR-R5 121-001 Attachment B, Rev. C~Preliminary Data Review Form -Samples for the Sign Test Survey Unit: Survey Unit Name: Classification:

Survey Media: Type of Survey: Type of Measurement:

Number of Measurements:

Operational DCGL: 9106- 0014 Discharge Canal 2 Soil Final Status Survey Gross Measurement 42 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Minimum Value: 3.95E-06 -1.63E-03 Maximum Value: 1.36E+00 2.07E+00 Mean: 2.22E-01 4.34E-01 Median: 1.19E-01 1.77E-01 Standard Deviation:

2.87E-0 1 5.40E-01 NUMBER 9106-0014-001F 9106-0014-002F 9106-0014-003F 9106-0014-005F 9106-0014-006F 9106-0014-007F 9106-0014-008F 9106-0014-009F 9106-0014-01OF 9106-0014-01 IF 9106-0014-012F 9106-0014-013F 9106-0014-014F 9106-0014-015F 9106-0014-016F 9106-0014-017F 9106-0014-018F 9106-0014-019F 9106-0014-020F 9106-0014-02 1F 9106-0014-022F 9106-0014-023F 9106-0014-024F Cs-137 1.41 E-03 3.61 E-03 3.95E-06 5.45E-02 2.42E-01 1.61 E-01 9.66E-02 1.64E-01 3.63E-01 3.56E-02 1.15E+00 2.19E-01 1.47E-02 5.85E-02 6.89E-02 5.52E-01 2.93E-01 7.49E-01 5.94E-02 1.17E-01 1.15E-01 4.53E-02 2.41 E-02 RADIONUCLIDE Co-60 8.94E-03 2.52E-03 1.15E-02 2.88E-02 2.67E-01 2.17E-01 1.60E-01 5.99E-02 2.38E-01 5.76E-03 1.45E+00 1.36E-01 1.13E-02 1.68E-01 1.05E-01 5.93E-01 8.95E-01 1.32E+00 6.60E-02 4.50E-01 2.89E-02 4.90E-02-1.63E-03 CONCENTRATION (pCi/g)Cs Identified?

Co Identified?

NO NO NO NO NO NO YES YES YES YES YES YES YES YES YES YES YES YES YES NO YES YES YES YES NO NO YES YES YES YES YES YES YES YES YES YES YES NO YES YES YES NO YES YES NO NO 9106-0014-025F 9106-0014-026F 9106-0014-027F 9106-0014-028F 9106-0014-029F 9106-0014-030F 9106-0014-031F 9106-0014-032F 9106-0014-033F

,9106-0014-034F 9106-0014-035F 9106-0014-036F

,9106-0014-037F o9106-0014-038F 9106-0014-039F 9106-0014-040F 9106-0014-042F 9106-0014-042F 9106-001 4-043F 5.50E-01 1.20E-01 1.66E-01 8.72E-02 5.80E-02 3.89E-02 3.85E-02 2.55E-01 1.36E+00 3.OOE-01 2.OOE-01 7.85E-02 3.26E-01 3.47E-01 3.77E-01 9.62E-02 4.76E-02 1.52E-01 1.29E-01 1.36E+00 1.52E-01 4.69E-01 1.86E-01 9.38E-02 2.49E-02 3.90E-02 3.98E-01 2.07E+00 1.01E+00 2.49E-01 3.41 E-01 1.23E+00 1.60E+00 1.36E+00 4.36E-01 1.47E-01 6.66E-01 1.08E-01 YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES 2424?Performed By: Independent Review:/ " Date: (- 045-,i.Date: 0i- -06 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cesium -137 Survey Unit: 9106-014 Survey Unit Name: Discharge Canal Mean: 2.22E-01 pCi/g 1.60E+00 1.40E+00 .... -" 1.20E+00 -r 1.OOE+00 -0 8.OOE-01 ... , ._6.OOE-01 4.OOE-01 2.OOE-01 -* -_-0.00E+00 *41* *,*0 20 40 60 80 100 Percentage Cs-1 37 Rank Percentage 3.95E-06 1.41 E-03 3.61 E-03 1.47E-02 2.41 E-02 3.56E-02 3.85E-02 3.89E-02 4.53E-02 4.76E-02 5.45E-02 5.80E-02 5.85E-02 5.94E-02 6.89E-02 7.85E-02 8.72E-02 9.62E-02 9.66E-02 1.15E-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1%4%6%8%11%13 %15 %18 %20 %23 %25 %27 %30 %32 %35 %37 %39 %42 %44 %46 %Page 1 of 2 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cesium -137 1.15E-01 1.17E-01 1.29E-01 1.52E-01 1.61E-01 1.64E-01 1.66E-01 2.OOE-01 2.19E-01 2.42E-01 2.55E-01 2.93E-01 3.OOE-01 3.26E-01 3.47E-01 3.63E-01 3.77E-01 5.50E-01 5.52E-01 7.49E-01 1.15E+00 1.36E+00 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 49 %51 %54 %56 %58 %61 %63 %65 %68 %70 %73 %75 %77 %80 %82 %85 %87 %89 %92 %94 %96 %99 %4ýq a 0 'Z-Prepared By: Reviewed By: /Date: // , 0 -O Date: 0/ /- -& .(Page 2 of 2 Health Physics Procedure GGGR-R5123-Rev.CY-00 I Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cobalt -60 Survey Unit: 9106-014 Survey Unit Name: Discharge Canal Mean: 4.34E-01 pCi/g 2.50E+00 -...2.OOE+00 1.50E+00 .1.00E+00 -. ,. " _ 4'S 5.OOE-01 V, O.OOE+00 4'1 "O):.. 2 ,. ,,: 3' '60 8" ' <]' -5.OOE-01 Percentage Co-60 Rank Percentage

-1.63E-03 2.52E-03 5.76E-03 8.94E-03 1.13E-02 1.15E-02 2.49E-02 2.88E-02 2.89E-02 3.90E-02 4.90E-02 5.99E-02 6.60E-02 9.38E-02 1.05E-01 1.08E-01 1.36E-01 1.47E-01 1.52E-01 1.60E-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 4 6 8 11 13 15 18 20 23 25 27 30 32 35 37 39 42 44 46 Page 1 of 2 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cobalt -60 1.68E-01 1.86E-01 2.17E-01 2.38E-01 2.49E-01 2.67E-01 3.41 E-01 3.98E-01 4.36E-01 4.50E-01 4.69E-01 5.93E-01 6.66E-01 8.95E-01 1.01E+00 1.23E+00 1.32E+00 1.36E+00 1.36E+00 1.45E+00 1.60E+00 2.07E+00 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 49 51 54 56 58 61 63 65 68 70 73 75 77 80 82 85 87 89 92 94 96 99 b69z 2&1/d Prepared By: Reviewed By:____________

_____Date: /(- /,3 -0 , Date: -.0 I 90 Page 2 of 2 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cesium-137 Survey Unit: 9106-014 Survey Unit Name: Discharge Canal Mean: 0.222 pCi/g 30 25.~20 15 ,.2 10 " ' *,' " '. .16 10 -,* ":".U-5 '0 -. --'0.2 0.4 0.6 0.8 1.0 1.2 1.4 Upper End Value (pCilg)Upper End Observation Observation

%Value Frequency Frequency 0.2 28 67%0.4 9 21%0.6 2 5%0.8 1 2%1.0 0 0%1.2 1 2%1.4 1 2%Total 42 100%Prepared By: Reviewed By: 694)/Date: Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-014 Survey Unit Name: Discharge Canal Mean: 0.434 pCi/g 30 25 r20 S15 210 L_0I m i 0.333 0.667 1.000 1.333 1.670 2.000 2.333 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.333 26 62%0.667 7 17%1.000 1 2%1.333 3 7%1.670 4 10%2.000 0 0%2.333 1 2%Total 42 100%Prepared By: Date: --Date: Reviewed By: 0)

DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2e Sign Test Calculation (2 Page)

Health Physics Procedure GPP-GGGR-R512 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-014 Survey Unit Name: Discharge Canal WP&IR#: 2006-02 1 Classification:

2 TYPE I(a error):0.05 TYPE I (j3 error):0.05 Radionuclides:

Cs-137 Co-60 Operational DCGL (pCi/g): 5.38 2.59 Results Cs-137 1.411E-03 3.6 1E-03 3.95E-06 5.45E-02 2.42E-0 1 1.61E-01 9.66E-02 1.64E-01 3.63E-01 3.56E-02 1.15E+00 2.19E-01 1.47E-02 5.85E-02 6.89E-02 5.52E-01 2.93E-01 7.49E-0 1 5.94E-02 1.17E-01 1.15E-01 4.53E-02 2.4 1E-02 5.50E-01 1.20E-01 1.66E-01 8.72E-02 5.80E-02 3.89E-02 3.85E-02 2.55E-01 1.36E+00 3.OOE-0 1 2.OOE-0 1 Results Co-60 8.94E-03 2.52E-03 1.15E-02 2.88E-02 2.67E-0 1 2.17E-01 1.60E-01 5.99E-02 2.38E-01 5.76E-03 1.45E+00 1.36E-01 1.13E-02 1.68E-01 1.05E-01 5.93E-01 8.95E-01 1.32E+00 6.60E-02 4.50E-01 2.89E-02 4.90E-02-1.63E-03 1.36E+00 1.52E-01 4.69E-0 1 1.86E-01 9.38E-02 2.49E-02 3.90E-02 3.98E-01 2.07E+00 1.01E+00 2.49E-01 Weighted Sum (W,)3.7 1E-03 1.64E-03 4.44E-03 2.12E-02 1.48E-01 1.14E-01 7.97E-02 5.36E-02 1.59E-01 8.84E-03 7.74E-0 1 9.32E-02 7.10E-03 7.57E-02 5.33E-02 3.32E-01 4.OOE-01 6.49E-0 I 3.65E-02 1.95E-01 3.25E-02 2.73E-02 3.85E-03 6.27E-01 8. 1OE-02 2.12E-01 8.80E-02 4.70E-02 1.68E-02 2.22E-02 2.01E-01 1.05E+00 4.46E-0 I 1.33E-01 1 of 2 DCGL-Result 9.96E-0 1 9.98E-01 9.96E-0 1 9.79E-0 1 8.52E-0 1 8.86E-01 9.20E-0 1 9.46E-0 1 8.41E-01 9.91E-01 2.26E-0 1 9.07E-0 1 9.93E-01 9.24E-01 9.47E-0 1 6.68E-01 6.00E-01 3.51E-01 9.63E-0 1 8.05E-0 I 9.67E-0 1 9.73E-01 9.96E-0 I 3.73E-01 9.19E-01 7.88E-01 9.12E-01 9.53E-01 9.83E-01 9.78E-01 7.99E-0 1-5.20E-02 5.54E-0 1 8.67E-01 Sign 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1-1-1 1 Results Cs-137 7.85E-02 3.26E-0 1 3.47E-01 3.77E-0 1 9.62E-02 4.76E-02 1.52E-0 1 1.29E-01 Results Co-60 3.41 E-0 1 1.23E+00 1.60E+00 1.36E+00 4.36E-01 1.47E-01 6.66E-01 1.08E-01 Weighted Sum (W,)1.46E-01 5.35E-01 6.82E-0 1 5.95E-01 1.86E-01 6.56E-02 2.85E-01 6.57E-02 DCGL-Result 8.54E-01 4.65E-0 1 3.18E-O1 4.05E-01 8.14E-01 9.34E-0 1 7.15E-01 9.34E-01 Sign 1 1 1 I 1 1 1 1 Number of Positive Differences (S+): 42 Critical Value: 26 Survey Unit: Meets Acceptance Criterion£6ý2 K,ýZ Performed By: Independent Review: Date: //- 13 -Oz Date: // V 0 2 of 2 DISCHARGE CANAL SURVEY UNIT 9106-0014 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (5 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0014 (17 mrem/yr)Dale Randall Discharge Canal SU 9106-0014 1 42 0 Sign Test Result: Pass 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve U I--L 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0: ms -_I -I -i--!- --j zzJ__0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of-Raties, including background

-, -Prospective Power U 1-beta ....Actual Power-LBGR --Estimated Power DCGL ---- Retrospective Power 1.2 COMPASS vl.0.0 1111512006 Page1I

  1. DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0014-001F 9106-0014-002F 9106-0014-003F 9106-0014-005F 9106-0014-006F 9106-0014-007F 9106-0014-008F 9106-0014-009F 9106-0014-01OF 9106-0014-011 F 9106-0014-012F 9106-0014-013F 9106-0014-014F 9106-0014-015F 9106-0014-016F 9106-0014-017F 9106-0014-018F 9106-0014-019F 9106-0014-020F 9106-0014-021 F 9106-0014-022F 9106-0014-023F 9106-0014-024F 9106-0014-025F 9106-0014-026F 9106-0014-027F 9106-0014-028F 9106-0014-029F 9106-0014-030F 9106-0014-031F 9106-0014-032F 9106-0014-033F 9106-0014-034F 9106-0014-035F 9106-0014-036F 9106-0014-037F 9106-0014-038F 9106-0014-039F 9106-0014-040F 9106-0014-041F 9106-0014-042F 9106-0014-043F Type S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Co-60 (pCi/g)0.01 0 0.01 0.03 0.27 0.22 0.16 0.06 0.24 0.01 1.45 0.14 0.01 0.17 0.1 0.59 0.9 1.32 0.07 0.45 0.03 0.05 0 1.36 0.15 0.47 0.19 0.09 0.02 0.04 0.4 2.07 1.01 0.25 0.34 1.23 1.6 1.36 0.44 0.15 0.67 0.11 Cs-137 (pCi/g)0 0 0 0.05 0.24 0.16 0.1 0.16 0.36 0.04 1.15 0.22 0.01 0.06 0.07 0.55 0.29 0.75 0.06 0.12 0.12 0.05 0.02 0.55 0.12 0.17 0.09 0.06 0.04 0.04 0.26 1.36 0.3 0.2 0.08 0.33 0.35 0.38 0.1 0.05 0.15 0.13 COMPASS vl.0.0 1111512006 Page 2 4 DQA Surface Soil Report Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0014-001 F 9106-0014-002F 9106-0014-003F 9106-0014-005F 9106-0014-006F 9106-0014-007F 9106-0014-008F 9106-0014-009F 9106-0014-01 OF 9106-0014-011 F 9106-0014-012F 9106-0014-013F 9106-0014-014F 9106-0014-01 5F 9106-0014-016F 9106-0014-017F 9106-0014-018F 9106-0014-019F 9106-0014-020F 9106-0014-021 F 9106-0014-022F 9106-0014-023F 9106-0014-024F 9106-0014-025F 9106-0014-026F 9106-0014-027F 9106-0014-028F 9106-0014-029F 9106-0014-030F 9106-0014-031F 9106-0014-032F 9106-0014-033F 9106-0014-034F 9106-0014-035F 9106-0014-036F 9106-0014-037F 9106-0014-038F 9106-0014-039F 9106-0014-040F 9106-0014-041F 9106-0014-042F 9106-0014-043F Type S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0 0 0 0.02 0.15 0.11 0.08 0.05 0.16 0.01 0.77 0.09 0.01 0.08 0.05 0.33 0.4 0.65 0.04 0.2 0.03 0.03 0 0.63 0.08 0.21 0.09 0.05 0.02 0.02 0.2 1.05 0.45 0.13 0.15 0.54 0.68 0.6 0.19 0.07 0.29 0.07 COMPASS vl.0.0 11/1512006 Page 3 W DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 42 N/A N=15 Mean (SOR) 0.21 N/A 0.35 Median (SOR) 0.09 N/A N/A Std Dev (SOR) 0.26 N/A 0.29 High Value (SOR) 1.05 N/A N/A Low Value (SOR) 0.00 N/A N/A Statistical Test Summary S+: 41 Critical Value: 26 Result: Pass Data DCGLw -Data Sign 0 1.00 +0 1.00 +0 1.00 +0.02 0.98 +0.15 0.85 +0.11 0.89 +0.08 0.92 +0.05 0.95 +0.16 0.84 +0.01 0.99 +0.77 0.23 +0.09 0.91 +0.01 0.99 +0.08 0.92 +0.05 0.95 +0.33 0.67 +0.4 0.60 +0.65 0.35 +0.04 0.96 +0.2 0.80 +0.03 0.97 +0.03 0.97 +0 1.00 +0.63 0.37 +0.08 0.92 +0.21 0.79 +0.09 0.91 +COMPASS vl.0.0 11/1512006 Page 4

',j DQA Surface Soil Report Statistical Test Summary Data DCGLw -Data Sign 0.05 0.02 0.02 0.2 1.05 0.45 0.13 0.15 0.54 0.68 0.6 0.19 0.07 0.29 0.07 0.95 0.98 0.98 0.80-0.05 0.55 0.87 0.85 0.46 0.32 0.40 0.81 0.93 0.71 0.93+-I++++++++++++COMPASS v1.0.0 11/1512006 Page 5