Text

ZIONSOLUTIONSLC AnEorgyoSo Company April 28, 2015 ZS-2015-0055 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Zion Nuclear Power Station, Units 1 and 2 Facility Operating License Nos. DPR-39 and DPR-48 NRC Docket Nos. 50-295, 50-304 and 72-1037

Subject:

Radioactive Effluent Release Report, Radioactive Effluent Control Program Report, Offsite Dose Calculation Manual and Process Control Program for 2014 In accordance with the ZionSolutions,LLC, Quality Assurance Project Plan, Appendix B, Section 5.7.3, "Radioactive Effluent Release Report," enclosed is the Radioactive Effluent Release Report for the year 2014. Certificate of Compliance No. 1031 for the MAGNASTOR SYSTEM, Appendix A, Technical Specifications 5.1.1 and 5.1.3 require submittal of an Annual Radioactive Effluent Control Program report which is included in this document in Attachment 4.4.

Pursuant to 10 CFR 50.4 and Offsite Dose Calculation Manual (ODCM), Section 12.7.4, there were changes made to the Zion Station Liquid Effluent Treatment System in 2014. The changes to the Liquid Effluent Treatment System are described in Attachment 7. There were surveillances conducted for an inoperable plant monitoring system that exceeded the 30 day time limit listed in ODCM Section 12.2.2. ODCM Section 12.7.2 requires explanation as to why the inoperable monitoring system was not corrected within 30 days. Attachment 8 provides this explanation and a summary of the station review conducted and corrective actions implemented to restore the plant monitoring system to operable status.

There were no changes modifying intent or methodology to the ODCM or the Process Control Program during 2014. Therefore, they are not included with the submittal.

There are no new regulatory commitments in this submittal.

If you have any questions about this submittal please contact Mr. Christopher Keene at (224)789-4073.

Respectfully, 6 ,,,ai~-,,{ A, to Gerard van Noordennen Vice President Regulatory Affairs 101 Shiloh Boulevard, Zion

  • IL 60099 (224) 789-4016
  • Fax: (224) 789-4008 - www.zionsolutionscompany.com A *" . " c

ZionSolutions, LLC ZS-2015-0055 Page 2 of 2

Enclosure:

Zion Station 2014 Annual Radioactive Effluent Release Report cc: John Hickman, U.S. NRC Senior Project Manager Service List

Zion Nuclear Power Station, Unit 1 and 2 License Transfer Service List cc:

Ken Robuck Alwyn C. Settles President Logistics Processing and Section Head, Nuclear Facility Inspection Disposal Group Bureau of Nuclear Facility Safety EnergySohltions Illinois Emergency Management Agency 423 West 300 South, Suite 200 1011 North St., PO Box 250 Salt Lake City, UT 84101 Mazon, IL 60444 John Sauger Kelly F. Grahn Executive VP & General Manager Senior Health Physicist, Unit Supervisor ZionSolutions, LLC Bureau of Radiation Safety, Environmental 101 Shiloh Boulevard Management Zion, IL 60099 Illinois Emergency Management Agency 245 W Roosevelt Road, Building 8, Suite 55 Gerard van Noordennen West Chicago, IL 60185 VP Regulatory Affairs ZionSolutions, LLC Kent McKenzie 101 Shiloh Boulevard Emergency Management Coordinator Zion, IL 60099 Lake County Emergency Management Agency 1303 N. Milwaukee Avenue Anthony Orawiec Libertyville, IL 60048-1308 Decommissioning Plant Manager ZionSohitions, LLC Regional Administrator 101 Shiloh Boulevard U.S. NRC, Region III Zion, IL 60099 2443 Warrenville Road Lisle, IL 60532-4352 Dan Shrum Senior VP Regulatory Affairs John E. Matthews EnergySolutions Morgan, Lewis & Bockius LLP 423 West 300 South, Suite 200 1111 Pennsylvania Avenue., NW Salt Lake City, UT 84101 Washington, DC 20004 Russ Workman General Counsel EnergySolutions 423 West 300 South, Suite 200 Salt Lake City, UT 84101

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Zion Station 2014 Annual Radioactive Effluent Release Report

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 List of Attachments Attachment # Description I Supplemental Information 2 Effluent & Waste Disposal Summary 2.1 Unit 1 Gaseous Effluent 2.2 Unit 2 Gaseous Effluent 2.3 Liquid Effluent 2.4 Direct Radiation 2.5 LLD's 2.6 Error Estimation 3 Solid Waste and Irradiated Fuel Shipments 4 Radiological Impact on Man 4.1 40CFR 190 & 10CFR72 Compliance summary 4.2 Unit 1 4.3 Unit 2 4.4 ISFSI 4.5 Combined 40CFRI90 report 5 Meteorology Data 6 Errata Data from previous years 7 Summary of Liquid Radwaste System Changes 8 Corrective Actions for Inoperable Rad Monitor >30 days

ZionSohltions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 1- Supplemental Information

1. Regulatory Limits: The dose to a member of the public from direct radiation, liquid and gaseous effluents released from each unit to areas at or beyond site boundary shall be limited to the following:
a. Fission and Activation products:
i. Tech Spec Whole Body: 500 mrem/year ii. Tech Spec Skin: 3000 mrem/year
b. Particulates with half-lives > 8 days, tritium and Iodine:
i. Tech Spec Organ: 1500 mrem/year ii. I OCFR50 Organ: 7.5 mrem/quarter, 15 nrern/year
c. Liquid Effluents:
i. 10CFR50 Whole body: 1.5 mrem/quarter, 3 mrem/year ii. 10CFR50 Organ: 5 mrem/quarter, 10 mrem/year
d. Combined dose to real individual beyond controlled area:
i. 10CFR72 Whole body: 25 mrem/year ii. 10CFR72 Thyroid: 75 mrem/year iii. 10CFR72 Organ: 25 mrem/year
2. Effluent Concentration Limits (ECL): Limits used in determining allowable release rates or concentrations.
a. Gaseous Effluents: 10CFR20 Appendix B Table 2 Column 1.
b. Liquid Effluents: 10 X 10CFR20 Appendix B Table 2 Column 2.
3. Measurements and Approximations of Total Radioactivity.
a. Fission and Activation Products: 100% Kr-85 is assumed in calculations since other isotopes have decayed. Vent stack activity is continuously monitored for fission and activation gases.
b. Particulate releases are continuously monitored and samples collected and analyzed weekly for particulates and tritium. Particulate filters are sent to an independent lab for quarterly composite analysis. 2RIA-PR49 Unit 2 gaseous effluent release monitor was replaced during the time period of Dec. 18-Dec. 29.

During this time period particulate activity was continuously monitored and analyzed daily in each of the three areas feeding into Unit 2 vent stack (i.e. Unit 2 purge system, Aux. building, Fuel Handling Building). A separate composite was sent to an independent lab for composite analysis during quarter 4. Tritium activity in gaseous releases are calculated from the water evaporation of water in the spent fuel pool and water filled reactor cavities.

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014

c. Liquid effluents are continuously monitored and isotopic analysis performed weekly. Liquid batch releases are mixed and a representative sample taken and analyzed prior to batch release. A complete analysis of all liquid volumes was performed by an offsite laboratory to determine hard to detect nuclide activity. A conservative ratio to Co-60 was calculated for each hard to detect nuclide. Prior to each batch release, these scaling factors were used to calculate the concentration of these hard to detect nuclides.
d. Occupancy factors were used in determining direct radiation dose to the maximally exposed member of the public based on habits of a real individual in ES&H Technical Support Document 13-009 "Member of the Public Dose from All Onsite Sources."
4. Batch Releases:
a. Liquid:
1. There were 50 liquid batch releases in 2014
2. Total time period for batch releases: 1.35E+05 min.
3. Maximum time period for a batch release: 6.56E+03 min.
4. Average time period for batch release: 2.70E+03 min.
5. Minimum time period for a batch release: 8.07E+02 min.
b. Gaseous: There were no gaseous batch releases in 2014.
5. Abnormal Releases:
a. Liquid: There were no liquid abnormal releases in 2014.
b. Gaseous: There were no gaseous abnormal releases in 2014.
6. Gaseous and Liquid Waste Treatment Systems and Process Control Program Zion Station ODCM Section 12.7.4 requires major changes to the Gaseous and Liquid Waste Treatment Systems to be reported in the Annual Radioactive Effluent Release Report.

Zion Station ODCM Section 12.7.2 requires major changes to the Process Control Program(PCP) to be submitted in the Annual Radioactive Effluent Release Report.

The Waste Gas Hold-up System was permanently vented. In Zion's defueled configuration this system is no longer applicable.

In Zion's defueled configuration, the charcoal iodine removal system is no longer applicable.

Due to radioactive decay and no means of production, radioactive iodine is not a concern at Zion.

7. Limiting Conditions of Operation (LCOs)

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Zion Station ODCM Section 12.7.2 requires explanation as to why the inoperability of liquid or gaseous monitoring instrumentation was not corrected within the time specified in the ODCM to be submitted with the Annual Radioactive Effluent Release Report.

Unit 2 Vent Stack 2RIA-PR49 SPING monitor had an electronic malfunction. The mechanical portion of the SPING monitor was still operating normally and still maintaining a representative sample of Unit 2 gaseous effluent, thus the normal pathway and mechanical components were used to perform the daily surveillances required for inoperable radiation monitor. ODCM section 12.2.2 requires the system be restored to operational status or a station review conducted to determine the course of action to restore the gaseous effluent radiation monitor to operable status. No repair parts were able to be found to repair the electronics of the SPING unit and no replacement was found to be available as the Eberline SPING radiation monitor is no longer manufactured nor supported causing Zion Station to perform surveillances from Nov. 11 to Dec. 29 (49 days). A station review was conducted and the course of action decided upon to restore the radiation effluent monitor to operable status was to replace the SPING unit that monitors Unit 2 vent stack with a new radiation monitor identical to the one currently used monitoring Unit I vent stack. The radiation monitor was replaced and is working properly. Attachment 8 is the summary of the review conducted and the actions taken to restore system operation.

8. Liquid Holdup Tanks and Gas Storage Tanks Zion Station ODCM Section 12.7.2 requires a description of events leading to liquid holdup tanks or gas storage tanks exceeding technical specification limits to be included in the Annual Radioactive Effluent Release Report.

The contents of the six gas decay tanks have been sampled and determined to have negligible activity. The Gas Decay Tanks have been abandoned in place.

No liquid holdup tanks exceeded the limits of Permanently Defueled Technical Specifications 5.6.3 during 2014.

9. Offsite Dose Calculation Manual (ODCM)

Changes to the ODCM and Process Control Program are required by Zion Station Permanently Defueled Technical Specification 5.6.1, and ODCM Section 12.6.3 to be submitted as part of, or concurrent with, the Annual Radioactive Effluent Release Report.

a. ODCM Revisions: There were no major changes to the ODCM in 2014
b. Process Control Program(PCP): There were no major changes to the PCP in 2014.
10. Switchyard Area The switchyard is an onsite area that is monitored for direct radiation dose. Access to the site is controlled by Commonwealth Edison and is not accessible to members of the

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 general public. The dose limits for this area are regulated differently than the general offsite dose areas and comply with 10CFR20 annual dose limit of 100 mnrem/year. ES&H TSD 13-009 lists the evaluation performed to determine habits of the real individual working in the switchyard and are calculated to be occupied no more than 2088 hour0.0242 days <br />0.58 hours <br />0.00345 weeks <br />7.94484e-4 months <br />s/year.

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.1 - Unit 1 Gaseous Releases GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Unit 1 Vent Stack - GROUND RELEASES REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases

1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Iodine-131
1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Particulates Half Life >= 8 days
1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Tritium
1. Total Release Ci 6.95E-03 1.15E-02 1.15E-02 2.33E-02 5.32E-02
2. Avg. Release Rate uCi/sec 8.94E-04 1.46E-03 1.44E-03 2.92E-03 1.69E-03 GASEOUS EFFLUENTS - GROUND RELEASES - CONTINUOUS MODE REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases <LLD <LLD <LLD <LLD <LLD Iodines <LLD <LLD <LLD <LLD <LLD Particulates Half Life >= 8 days<LLD <LLD <LLD <LLD <LLD Tritium H-3 Ci 6.95E-03 1. 15E-02 1. 15E-02 2. 33E-02 5. 32E-02 Totals for Period Ci 6.95E-03 1. 15E-02 1. 15E-02 2. 33E-02 5. 32E-02 GASEOUS EFFLUENTS - GROUND RELEASES - BATCH MODE REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR No Batch Releases.

LLD values are listed on attachment 2.5 Total Error values are listed on attachment 2.6

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.2 - Unit 2 Gaseous Releases GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Unit 2 Vent Stack - GROUND RELEASES REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases

1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Iodine-131
1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Particulates Half Life >= 8 days
1. Total Release Ci <LLD <LLD <LLD 4.05E-05 4.05E-05
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD 5.10E-06 1.29E-06 Tritium
1. Total Release Ci 6.95E-03 1.15E-02 1.15E-02 2.33E-02 5.32E-02
2. Avg. Release Rate uCi/sec 8.94E-04 1.46E-03 1.44E-03 2.92E-03 1.69E-03 GASEOUS EFFLUENTS - GROUND RELEASES - CONTINUOUS MODE REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Gases <LLD <LLD <LLD <LLD <LLD Iodines <LLD <LLD <LLD <LLD <LLD Particulates Half Life >= 8 days CO-60 Ci <LLD <LLD <LLD 1. 81E-06 1. 81E-06 CS-137 Ci <LLD <LLD <LLD 1. 34E-06 1. 34E-06 NI-63 Ci <LLD <LLD <LLD 3. 74E-05 3. 74E-05 Totals for Period... Ci <LLD <LLD <LLD 4. OSE-05 4. 05E-05 Tritium H-3 Ci 6.95E-03 1.15E-02 1. 15E-02 9. lOE-03 3.25E-02 Totals for Period Ci 6.95E-03 1.15E-02 1. 15E-02 9.lOE-03 3.25E-02 GASEOUS EFFLUENTS - GROUND RELEASES - BATCH MODE REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR No Batch Releases.

LLD values are listed on attachment 2.5 Total Error values are listed on attachment 2.6

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.3 - Liquid Effluent Releases LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES (Unit 1 & Unit 2 combined)

REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation products (not including Alpha and Tritium)

1. Total Release Ci <LLD 1.40E-03 1.68E-02 1.87E-02 3. 69E-02
2. Avg. Release Rate uCi/sec <LLD 1.78E-04 2.11E-03 2.35E-03 1. 17E-03 Tritium
1. Total Release Ci <LLD 1.21E-01 6.94E-01 2.48E-01 1.06E+00
2. Avg. Release Rate uCi/sec <LLD 1.54E-02 8.73E-02 3.12E-02 3.36E-02 Dissolved and Entrained Gases
1. Total Release Ci <LLD <LLD <LLD <LLD <LLD
2. Avg. Release Rate uCi/sec <LLD <LLD <LLD <LLD <LLD Gross Alpha Radioactivity
1. Total Release Ci <LLD <LLD 1.57E-06 <LLD 1.57E-06
2. Avg. Release Rate uCi/sec <LLD <LLD 1.97E-07 <LLD 4.98E-08 Volume of liquid waste liters 2.64E+06 4.28E+06 6.09E+06 5.15E+06 1.82E+07 Volume of dil. water liters 1.23E+09 1.24E+09 1.25E+09 1.25E+09 4.97E+09 LIQUID EFFLUENTS - CONTINUOUS MODE (Unit 1 & Unit 2 combined)

REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR

<LLD Fission and Activation Gases <LLD <LLD <LLD <LLD

<LLD Tritium <LLD <LLD <LLD <LLD

<LLD Dissolved and Entrained Gases <LLD <LLD <LLD <LLD

<LLD Gross Alpha Radioactivity <LLD <LLD <LLD <LLD

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.3 - Liquid Effluent Releases (continued)

LIQUID EFFLUENTS - BATCH MODE (Unit 1 & Unit 2 combined)

REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Fission and Activation Products AG-108M Ci N/A 6. 88E-09 1. 95E-07 0.00E+00 2. 02E-07 C-14 Ci N/A 2. 52E-07 4. 38E-04 5.40E-04 9. 78E-04 CO-60 Ci N/A 8 OOE-04 2. 50E-03 1.23E-03 4. 53E-03 CS-137 Ci N/A 0 00E+00 2 . l0E-04 1.31E-06 2. 11E-04 FE-55 Ci N/A 2 82E-06 1. 55E-04 1. 92E-04 3.50E-04 NI-59 Ci N/A 8 44E-06 3. 01E-04 3. 71E-04 6. 80E-04 NI-63 Ci N/A 5. 44E-04 1. 30E-02 1. 62E-02 2. 97E-02 PU-241 Ci N/A 7 82E-07 1. 03E-05 1.27E-05 2. 38E-05 SB-125 Ci N/A 4. 62E-05 2. 53E-05 0. 0OE+00 7 .15E-05 SR-90 Ci N/A 3. 55E-07 1. 68E-04 2. 08E-04 3.77E-04 Totals for Period Ci N/A 1.40E-03 1. 68E-02 1. 87E-02 3. 69E-02 Tritium H-3 Ci N/A 1.21E-01 6. 94E-01 2. 48E-01 1. 06E+00 Totals for Period Ci N/A 1.21E-01 6. 94E-01 2.48E-01 1. 06E+00 Dissolved and Entrained Gases N/A <LLD <LLD <LLD <LLD Gross Alpha Radioactivity ALPHA Ci N/A 0.00E+00 1.57E-06 0. OOE+00 1. 57E-06 Totals for Period Ci N/A 0. OOE+00 1.57E-06 0 . OOE+00 1. 57E-06 LLD values are listed in attachment 2.5 Total Error values are listed on attachment 2.6

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.3 - Liquid Effluent Releases (continued)

SUPPLEMENTAL INFORMATION LIQUID EFFLUENTS - BATCH MODE REPORT FOR 2014 Units QTR 1 QTR 2 QTR 3 QTR 4 YEAR Number of releases 0 4 23 23 50 Total release time minute*s N/A 1. 14E+04 5. 94E+04 6.44E+04 1.35E+05 Maximum release time minute*" N/A 3. 85E+03 4.25E+03 6.56E+03 6.56E+03 Average release time minute*" N/A 2. 85E+03 2. 58E+03 2.80E+03 2.70E+03 Minimum release time minute*" N/A 2.42E+03 8 . 07E+02 1.12E+03 8.07E+02 Permit dilution vol ltr N/A 1. 24E+08 7 . 35E+08 6.81E+08 1.54E+09 Permit dilution flow gpm N/A 2. 87E+03 3. 27E+03 2.80E+03 3.01E+03 Permit max total diluted concentration (no H-3) uCi/ml N/A 1.83E-08 1. 60E-07 1. 62E-07 1.62E-07 Period dilution vol ltr 1.23E+09 1.24E+09 1.25E+09 1 .25E+09 4. 97E+09 Period dilution flow gpm 2.51E+03 2. 50E+03 2. 49E+03 2.49E+03 2. 50E+03

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.4-Direct Radiation Maximally exposed sector: J (25mrem/year limit)

Unit Qtr 1 (mrem) Qtr 2 (mrem) Qtr 3 (mrem) Qtr 4 (mrem) 2014 (mrem)

Unit 1 2.23E-01 7.77E-01 1.97E+00 1.03E+00 4.OOE+00 Unit 2 2.23E-01 7.77E-01 1.97E+00 1.03E+00 4.OOE+00 ISFSI- 2.23E-01 7.77E-01 1.97E+00 1.03E+00 4.OOE+00 gamma IS0SI- O.OOE+00 1.50E-01 5.08-01 2.95E-01 9.53E-01 neutron Sum: 7.75E-01 2.48E+00 6.42E+00 3.39E+00 1.30E+01 Maximally exposed switchyard: Switchyard South (1 00mrem/year limit)

Switchyard Qtr 1 (mrem) Qtr 2 (mrem) Qtr 3 (mrem) Qtr 4 (mrem) 2014 (mrem)

Gamma 7.15E-01 1.30E+01 1.45E+01 1.98E+01 4.81E+01 Neutron O.OOE+00 8.35E-01 1.25E+00 1.89E+00 3.98E+00 Sum 7.15E-01 1.38E+01 1.58E+01 2.17E+01 5.21E+01

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.5-LLD's Various detectors were used on different counting platforms for the gaseous and liquid weekly effluent samples. The lower limit of detection(LLD) accompanies each counted sample and is verified to meet the following maximum LLD's:

A. Liquid Sample frequency Type of analysis Lower Limit of Detection (LLD) uCi/mL Weekly/prior to each release Principal Gamma Emitters: <5.OOE-07 Dissolved and Entrained <l.OOE-05 Gases Monthly composite Tritium <1 .OOE-05 Gross Alpha <1.OOE-07 Quarterly composite Sr-90 5.OOE-08 Fe-55, Ni-63 1.OOE-06 B. Gaseous Sample frequency Type of analysis Lower Limit of Detection (LLD) uCi/mL Continuous/daily/weekly Principle gamma emitters < .OOE- 11 Continuous Noble gas <1.OOE-06 Monthly Noble Gas / Principle gamma <1.OOE-04 emitters Tritium 1.OOE-06 Quarterly composite Sr-90 <1 .OOE- 1I Fe-55 <3.OOE-11 Ni-63 <1.OOE- 11 Gross Alpha <1.OOE-1 1

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 2.6-Error Estimation Estimates of Total Error The following is a calculated estimate of the maximum potential total error associated with reported values in the Annual Radioactive Effluent Release Report. The total error is determined by calculating the square root of the sum of the squares of the individual errors.

a. Gaseous Effluents Sampling Error 5%

Calibration Error 10%

Counting Statistics ErTor 17%

Sample Volume Error 10%

Total Error 23%

b. Liquid Effluents Sampling Error 5%

Calibration Error 10%

Counting Statistics Error 16%

Sample Volume Error 2%

Total Error 20%

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 3 - Solid Waste and Irradiated Fuel Shipments A. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel)

1. Types of Waste Total Total Types of Waste Quantity Activity Period (in 3

) (Ci) Error %

a. Spent Resins, filter sludges, 2.91E+01 3.07E+01 2014 2.50E+01 evaporator bottoms
b. Dry compressible waste, 14E+03 3.58E+01 2014 2.50E+01 contaminated equipment 2 3 I
c. Irradiated components, control rods, 6.96E+02 2.46E+04 2014 2.50E+01 etc.
d. Other (describe) 0.OOE+00 0.OOE+00 2014 2.50E+01

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 3 - Solid Waste and Irradiated Fuel Shipments (continued)

1. Estimate of major nuclide composition (by waste type)

Major Waste Type a. Waste Type b. Waste Type Waste Nuclide Resins, DAW d. Irradiated Type d.

Composition sludges contaminated components Other %

bottoms (%) equipment (%) (%)

Ag- 110m 0.OOE+00 0.OOE+00 1.04E-07 0.OOE+00 Am-241 1.1OE-08 2.15E-04 9.27E-08 0.OOE+00 C-14 5.08E-04 4.66E-04 4.97E-04 0.OOE+00 Ce-144 0.OOE+00 1.25E-04 1.76E-08 0.OOE+00 Cm-242 2.57E-12 8.43E-07 2.1 IE-10 0.OOE+00 Cm-243 1.33E-09 6.84E-05 2.31 E-08 0.OOE+00 Cm-244 1.30E-09 5.22E-07 1.77E-08 0.OOE+00 Co-60 7.30E-01 5.25E-01 5.80E-01 0.OOE+00 Cs-134 6.64E-09 1.43E-05 3.84E-07 0.OOE+00 Cs-137 1.80E-06 1.71-01 5.34E-05 0.OOE+00 Fe-55 9.33E-02 1.13E-01 8.67E-02 0.OOE+00 H-3 1.29E-03 3.94E-04 1.20E-03 O.OOE+00 1-129 5.80E-10 1.09E-05 4.11E-08 0.OOE+00 Mn-54 7.22E-07 7.22E-04 2.80E-05 0.OOE+00 Nb-94 9.62E-06 9.72E-04 9.97E-06 0.OOE+00 Ni-59 3.01E-03 2.96E-03 3.03E-03 0.OOE+00 Ni-63 0.OOE+00 1.73E-01 0.OOE+00 0.OOE+00 Ni-63am 1.72E-01 0.OOE+00 3.28E-01 0.OOE+00 Np-237 0.OOE+00 0.OOE+00 2.68E-07 0.OOE+00 Pu-238 9.81E-09 2.06E-04 8.53E-08 0.OOE+00 Pu-239 2.04E-09 6.07E-05 1.91E-08 0.OOE+00 Pu-240 2.04E-09 2.73E-06 1.35E-08 0.OOE+00 Pu-241 2.31E-07 1.71E-03 1.89E-06 0.OOE+00 Pu-242 7.33E-12 2.24E-07 5.22E-10 0.OOE+00 Ra-226 1.27E-07 3.66E-04 7.44E-06 0.OOE+00 Sb-125 1.68E-07 6.45E-03 2.98E-06 0.OOE+00 Sr-89 0.OOE+00 1.39E-04 3.32E-08 0.OOE+00 Sr-90 3.20E-08 1.26E-03 1.17E-06 0.OOE+00 Tc-99 6.23E-07 6.90E-04 9.13E-07 0.OOE+00 Zn-65 2.06E-07 1.25E-03 1.08E-07 0.OOE+00

  • Ni-63AM - activated metal

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 3 - Solid Waste and Irradiated Fuel Shipments (continued)

2. Solid Waste Disposition Number of shipments Mode of Transportation Destination 23 Truck Clive CWF 3 Rail Clive CWF 16 Rail Clive BWF 21 Truck WCS B. Irradiated Fuel Shipments (disposition)

Number of shipments Mode of Transportation Destination 0 N/A N/A C. Changes to the Process Control Program:

None

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.1 - 40CFR 190, 1OCRF72 & 10CFR20 Compliance Summary Radiological Impact on Man UNIT 1, 2 & ISFSI (DOCKET Numbers 50-295, 50-304 & 72-1037)

EXECUTIVE

SUMMARY

A review of 2014 effluent data indicates that the activity released from the station was far below any regulatory limit. There was no noble gas released in 2014. This trend can be attributed to the shutdown of both units since late September 1997.

Airborne Dose to Maximally Exposed Dose to Maximally Exposed Receptor from Unit 1 Receptor from Unit 2 Gamma Air O.OOE+00 mrad O.OOE+00 mrad Beta Air O.OOE+00 mrad O.OOE+00 mrad Total Body 3.43E-04 mrem 3.43E-04 mrem Skin 2.28E-04 mrem 2.28E-04 mrem Organ 3.70E-03mrem (Child Bone) 3.70E-03mrem (Child Bone)

Aquatic Dose to Maximally Exposed Dose to Maximally Exposed Receptor (Any) from Unit I Receptor (Any) from Unit 2 Total Body 9.75E-03 mrem 9.75E-03 mrem Organ 1.44E-01 mrem 1.44E-01 mrem Direct Radiation Dose to Maximally Dose to Maximally Dose to Maximally Exposed Member of the Exposed Member of the Exposed Member of public from Unit I public from Unit 2 the public from ISFSI Total Body 4.OOE+00mrem 4.OOE+00mrem 4.95E+00mrem Organ 4.00E+00mrem 4.00E+00mrem 4.95E+00mrem Switchyard Direct Radiation (1 OCFR20 limit 100mrem/year)

Dose to Maximally Exposed Switchyard worker Total Body 5.21E+01 mrem Organ 5.21E+01 mrem

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.2 - Unit 1 I. Unit I (Docket Number 50-295)

A. 10 CFR20 & 40CFR190 Compliance Assessment: The demonstration of compliance with 40CFR190 will be used to demonstrate compliance with 10CFR20.

1. Total Effective Dose Equivalent 4.01E+00 mrem/year
2. 40 CFR 190 Whole body limit 25 mrem/year
3. 40 CFR 190 Max exposed organ 25 mrem (75 mrem thyroid)
4. % Whole body limit 1.60E+01%
5. % Max exposed organ 1.66E+01% child bone (5.53E+00% thyroid)

Qtr 1 mrem Qtr 2 mrem Qtr 3 mrem Qtr 4 mrem 2014 mrem TEDE 2.23E-01 7.77E-01 1.98E+00 1.03E+00 4.01E+00 Organ 2.23E-01 7.79E-0l 2.04E+00 1.11E+00 4.15E+00 B. Maximally Exposed Receptor:

1. Airborne Qtr Obj I " Qtr 2"' Qtr 3" Qtr 4" Qtr Yearly limit Total Dose  % of 10CFR 50 2014 Yearly App. I limit Gamma air (mrad) 5.0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 10.0 0.OOE+00 0.OOE+00 Beta Air (mind) 10.0 0.OOE+00 O.OOE+00 0.00E+00 0.OOE+00 20.0 0.OOE+00 0.OOE+00 Total Body (mrem) 7.5 1.77E-05 2.93E-05 2.92E-05 2.67E-04 15.0 3.43E-04 2.29E-03 Skin (mrem) 7.5 1 .18E-05 1.95E-05 1.94E-05 1.77E-04 15.0 2.28E-04 1.52E-03 Organ (mrem) 7.5 1.77E-05 2.93E-05 2.92E-05 3.70E-03 15.0 3.70E-03 2.47E-02 Critical Organ Child liver Child liver Child liver Child bone Child bone Child bone
3. Aquatic Yearly limit Total Dose  % of Qtr Obj I Qtr 2 "d Qtr 3r Qtr 415Qtr 10CFR 50 2014 Yearly App. I limit Total Body (mrem) 2.5 0.OOE+00 1.19E-04 7.85E-03 2.41E-03 3.0 9.75E-03 3.26E-01 Organ (mrem) 2.5 0.OOE+00 2.09E-03 6.80E-02 7.30E-02 10.0 1.44E-01 2.87E+00 Critical Organ Child bone Child bone Child bone Child bone Child bone Child bone
4. Direct Yearly Qtr III Qtr 2 "d Qtr 3 d Qtr 41'Qtr limit Total Dose  % of Yearly limit Obj 40CFR 2014 190 Total body 6.25 2.23E-01 7.77E-01 1.97E+00 1.03E+00 25.0 4.OOE+00 1.60E-01 (mrem) I I IIIII

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.3 - Unit 2 II. Unit 2 (Docket Number 50-304)

A. 10 CFR20 & 40CFR190 Compliance Assessment: The demonstration of compliance with 40CFRl190 will be used to demonstrate compliance with 10CFR20.

1. Total Effective Dose Equivalent 4.01E+00 mrem/year
2. 40 CFR 190 Whole body limit 25 mrem/year
3. 40 CFR 190 Max exposed organ 25 mrem (75 mrem thyroid)
4. % Whole body limit 1.60E+01%
5. % Max exposed organ 1.66E+01% child bone (5.53E+00% thyroid)

Qtr 1 mrem Qtr 2 mrem Qtr 3 mrem Qtr 4 mrem 2014 mrem TEDE 2.23E-01 7.77E-01 1.98E+00 1.03E+00 4.01E+00 Organ 2.23E-01 7.79E-01 2.04E+00 1.11E+00 4.15E+00 B. Maximally Exposed Receptor:

1. Airborne Qtr Obj Iý Qtr 2" Qtr 3" Qtr 4t Qtr Yearly limit Total Dose  % of 10CFR 50 2014 Yearly App. I limit Gamma air (mrad) 5.0 0.OOE+00 0.00E+00 0.00E+00 O.00E+00 10.0 0.00E+00 0.00E+00 Beta Air (mrad) 10.0 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 20.0 0.00E+00 0.00E+00 Total Body (mrem) 7.5 1.77E-05 2.93E-05 2.92E-05 2.67E-04 15.0 3.43E-04 2.29E-03 Skin (mrem) 7.5 1.18E-05 1.95E-05 1.94E-05 1.77E-04 15.0 2.28E-04 1.52E-03 Organ (mrem) 7.5 1.77E-05 2.93E-05 2.92E-05 3.70E-03 15.0 3.70E-03 2.47E-02 Critical Organ Child liver Child liver Child liver Child bone Child bone Child bone
2. Aquatic Yearly limit Qtr I* Qtr 2nMQtr 3rd Qtr 4t' Qtr 10CFR 50 Total Dose %of Yearly limit Obj App. 1 2014 Total Body 2.5 0.OOE+00 1.19E-04 7.85E-03 2.41E-03 3.0 9.75E-03 3.26E-01 (mrem)

Organ 2.5 0.00E+00 2.09E-03 6.80E-02 7.30E-02 10.0 1.44E-01 (mirem)III 2.87E+00 ritical Child bone Child bone Child bone Child bone Child bone Child bone Organ ________ __________________________________

3. Direct Yearly Qt 10 Qtr 2 n" Qtr 3 rd Qt 4 thQtr limit Total Dose  % of Yearly limit Obj 40CFR 2014 190 Total body 6.25 2.23E-01 7.77E-01 1.97E+00 1.03E+00 25.0 4.00E+00 1.60E+0I (mrem ) , IIIIIIII

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.4 - ISFSI III. ISFSI (Docket Number 72-1037)

A. I OCFR72 & 40CFR190 Compliance Assessment:

1. Total Effective Dose Equivalent 4.95+00 mrem/year
2. 40 CFR1 90 / 10CFR72 Whole body limit 25 mrem/year
3. 40 CFR 190 / I OCFR72 Max exposed organ 25 mrem (75 mrem thyroid)
4.  % Whole body limit 1.98E+01%
5.  % Max exposed organ(child bone/thyroid) 1.98E+01% / 6.60E+00%

Qtr 1 rnrem I Qtr 2 mrem Qtr 3 mrem I Qtr 4 mrem 12014 mrem TEDE 2.23E-01 9.27E-01 2.49E+00 1.33E+00 4.95E+00 Organ 2.23E-01 9.27E-01 2.49E+00 1.33E+00 4.95E+00 B. Maximally Exposed Receptor:

1. Direct (gamma + neutron)

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.5 - Combined 40CRF190 Report IV. Combined 40CFR190 Report:

40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID ANNUAL DOSE

SUMMARY

2014 Zion 40CFR190 Year ..................... 2014 From Unit ............... 1 To Unit................: 2 Liquid Receptor .......  :.0 Liquid Receptor

=== MAXIMUM PERIOD DOSE TO LIMIT Any Organ)

Dose Age Dose Limit Admin Admin  % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Quarter 1 ADULT BONE 0. OE+00 Quarter 2. 50E+00 0. 0OE+00 2. 50E+00 0. 00E+00 Quarter 2 CHILD BONE 4. 17E-03 Quarter 2. 50E+00 1. 67E-01 2. 50E+00 1. 67E-01 Quarter 3 CHILD BONE 1. 36E-01 Quarter 2. 50E+00 5. 44E+00 2. 50E+00 5. 44E+00 Quarter 4 CHILD BONE 1.4 6E-01 Quarter 2. 50E+00 5. 85E+00 2. 50E+00 5. 85E+00 Annual CHILD BONE 2. 87E-01 Annual 5. OOE+00 5. 73E+00 5. OOE+00 5.73E+00

=== MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin  % T. Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Quarter 1 ADULT TBODY 0. OE+00 Quarter 1. 50E+00 0. 0OE+00 1. 50E+00 0. OOE+00 Quarter 2 CHILD TBODY 2 .37E-04 Quarter 1. 50E+00 1. 58E-02 1. 50E+00 1.58E-02 Quarter 3 ADULT TBODY 1. 57E-02 Quarter 1.50E+00 1. 04E+00 1. 50E+00 1. 04E+00 Quarter 4 CHILD TBODY 4. 81E-03 Quarter 1. 50E+00 3.21E-01 1. 50E+00 3.21E-01 Annual ADULT TBODY 1. 95E-02 Annual 3. OE+00 6. 52E-01 3. 00E+00 6. 52E-01

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.5 - Combined 40CRF190 Report LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS)------------

Release ID ............. 1 All Liquid Release Types Period Start Date ..... 01/01/2014 00:00 Period End Date ........ 01/01/2015 00:00 Period Duration (mins): 5.256E+05 Receptor ..............  : 0 Liquid Receptor

=== MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)

Dose Age Dose Limit Admin Admin  % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD BONE 2. 87E-0 1 31-day 5.OOE+00 5.73E+00 5.OOE+00 5.73E+00 Quarter 2.50E+00 1.15E+01 2.50E+00 1.15E+01 Annual 5.OOE+00 5.73E+00 5.OOE+00 5.73E+00 Critical Pathway ......... 1 Fresh Water Fish - Sport (FFSP)

Major Contributors ......  :.0.0  % or greater to total Nuclide Percentage H-3 0.OOE+00 FE-55 1.98E-02 CO-60 0.OOE+00 NI-63 7.85E+01 SR-90 1.49E+01 CS-137 6.67E+00

=== MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End ADULT TBODY 1.95E-0 2 31-day 3.OOE+00 6.52E-01 3.OOE+00 6.52E-01 Quarter 1.50E+00 1.30E+00 1.50E+00 1.30E+00 Annual 3.OOE+00 6.52E-01 3.OOE+00 6.52E-01 Critical Pathway .......... 1 Fresh Water Fish - Sport (FFSP)

Major Contributors ......  :.0.0  % or greater to total Nuclide Percentage H-3 2.55E-01 FE-55 3.37E-02 CO-60 2.34E+00 NI-63 2.81E+01 SR-90 4.39E+00 CS-137 6.50E+01

ZionSohltions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.5(continued) - Combined 40CRF 190 Report 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GAS ANNUAL DOSE

SUMMARY

2014 Zion 40CFR190 Year ..................... 2014 From Unit ................ 1 To Unit .................. 2 Coefficient Type ....... Hist orical Gas Receptor ............ 5 Coimposite Crit. Receptor - IP Distance (meters) ..... 0.00 Compass Point .......... NA

=== MA.XIMUM PERIOD DOSE TO LIMIT (Any Organ)

Dose Age Dose Limit Admin Admin  % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Quarter 1 CHILD LIVER Quarter 2 CHILD LIVER 3.54E-05 Quarter 5.63E+00 6.30E-04 7.50E+00 4.72E-04 Quarter 3 CHILD LIVER 5.86E-05 Quarter 5.63E+00 1.04E-03 7.50E+00 7.82E-04 5.84E-05 Quarter 5.63E+00 1.04E-03 7.50E+00 7.79E-04 Quarter 4 CHILD BONE 7.40E-03 Quarter 5.63E+00 1.32E-01 7.50E+00 9.87E-02 Annual CHILD BONE 7.40E-03 Annual 1.13E+01 6.58E-02 1.50E+01 4.93E-02

--- MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Quarter 1 CHILD TBODY 3.54E-05 Quarter 5.25E+00 6.75E-04 7.50E+00 4.72E-04 Quarter 2 CHILD TBODY 5.86E-05 Quarter 5.25E+00 6.72E-03 7.50E+00 7.82E-04 Quarter 3 CHILD TBODY 5.84E-05 Quarter 5.25E+00 1.lIE-03 7.50E+00 7.79E-04 Quarter 4 CHILD TBODY 5.34E-04 Quarter 5.25E+00 1.02E-02 7.50E+00 7.12E-03 Annual CHILD TBODY 6.86E-04 Annual 1.05E+01 6.54E-03 1.50E+01 4.57E-03

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.5(continued) - Combined 40CRF190 Report GASEOUS RELEASE AND DOSE

SUMMARY

REPORT (Composite Critical Receptor - Limited Analysis)

Release ID ........... 1 All Gas Releases Period Start Date.... 01/01/2014 00:00 Period End Date ....... 01/01/2015 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... Historical Receptor ............. 5 Composite Crit. Receptor - IP Distance (meters) .... 0.0 Compass Point ........ 0.0

=== MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)

Dose Age Dose Limit Admin Admin % T.Spec T.Spec Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD BONE 7.40E-03 31-day 2.25E-01 3.29E+00 3.OOE-01 2.47E+00 Quarter 5.63E+00 1.32E-01 7.50E+00 9.87E-02 Annual 1.13E+01 6.58E-02 1.50E+01 4.93E-02 Critical Pathway ........ .. 2 Vegetation (VEG)

Major Contributors ...... .. 0.0  % or greater to total Nuclide Percentage H-3 0.OOE+00 CO-60 1.08E+00 NI-63 9.32E+01 CS-137 5.65E+00

=== MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD TBODY 6.86E-04 31-day 1.50E-01 4.57E-01 2.OOE-01 3.43E-01 Quarter 5.25E+00 1.31E-02 7.50E+00 9.15E-03 Annual 1.05E+01 6.54E-03 1.50E+01 4.57E-03 Critical Pathway ........  :.2 Vegetation (VEG)

Major Contributors ...... .. 0.0  % or greater to total Nuclide Percentage H-3 3. 95E+01 CO-60 1.24E+01 NI-63 3. 42E+01 CS-137 1. 39E+01

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 4.5(continued) - Combined 40CRF 190 Report 40CFR190 URANIUM FUEL CYCLE DOSE REPORT COMBINED MAXIMUM ANNUAL DOSE

SUMMARY

2014 Zion 40CFR190 Year ..................... 2014 From Unit ................ 1 To Unit .................. 2 Liquid Receptor ........ 0 Li quid Receptor Coefficient Type ....... Hist orical Gas Receptor ............ 5 Co mposite Crit. Receptor - IP Distance (meters) ..... 0.00 Compass Point .......... NA

=== MAXIMUM PERIOD DOSE TO LIMIT (2Any Organ)

Dose Age Dose Limit Percent Period Group Organ (mrem) Period Limit of Limit 6.25E+00 5.67E-04 Quarter 1 CHILD LIVER 3.54E-05 Quarter 6.25E+00 6.67E-02 Quarter 2 CHILD BONE 4.17E-03 Quarter 6.25E+00 2.18E+00 Quarter 3 CHILD BONE 1.36E-01 Quarter 6.25E+00 2.46E+00 Quarter 4 CHILD BONE 1.54E-01 Quarter Annual CHILD BONE 2. 94E-01 Annual 2.50E+01 1.18E+00

=== MAXIMUM PERIOD DOSE TO LIMIT ( Tot Body))

Dose Age Dose Limit Percent Period Group Organ (mrem) Period Limit of Limit Quarter 1 CHILD TBODY Quarter 2 CHILD TBODY 3.54E-05 Quarter 6.25E+00 5.67E-04

2. 95E-04 Quarter 6.25E+00 4.72E-03 Quarter 3 ADULT TBODY 1.57E-02 Quarter 6.25E+00 2.51E-01 Quarter 4 CHILD TBODY 5. 34E-03 Quarter 6.25E+00 8.55E-02 Annual ADULT TBODY 2.00E-02 Annual 2.50E+01 8.00E-02

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 5 - Meteorological Data And Meteorological Data Appendix

Annual Report on the Meteorological Monitoring Program at the Zion Nuclear Power Station 2014 preparedfor Zlon Sollonas, LLC Zion, Illinois 60099 by Murray and Trette, Incorporated 600 First Bank Drive, Suite A Palatine, IL 60067 (847) 963-9000 e-mail: mt(mathercommand.com For Zlon l utns n -

Da '-2 -*

MUrM&ray& Hete,nc. 6WoFfrttBank Drive,SidteA PalatineIllioi 60067 (847) 963-9000

i Table of Contents Section Description Page List of Tables ........................................................................................... ii 1 Introduction ............................................................................................ 1 2 Sum mary ........................................................................................... 2 3 Data Acquisition .................................................................................. 3 4 Data Analysis .................................................................................... 5 5 Results .............................................................................................. 10 Site Calibration logs ................................................................... Appendix Murray & Trettel,Inc. 6oo FirstBank Drive,Site A Palatine,Illinois 60067 (847) 963-9000

ii List of Tables Number Description Page 1 Instrument Locations ........................................................................ 4 2 Data Loggers ................................................................................... 4 3 W ind Direction Classes ..................................................................... 7 4 W ind Speed Classes ........................................................................ 7 5 Atmospheric Stability Classes ......................................................... 8 6 Data Recovery Summary ................................................................ 11 7 W ind Rose, January-March 2014 ................................................... 14 8 Wind Rose, April-June 2014 ........................................................... 16 9 W ind Rose, July-September 2014 .................................................. 18 10 W ind Rose, October-December 2014 ............................................ 20 11 W ind Rose, January-December 2014 ............................................. 22 12 Precipitation Totals .......................................................................... 24 13 Maximum Doses Resulting From Airborne Releases .................... 25 Murray & Trettel, Inc. 6oo FirstBank Drive,Suite A Palatine,IlMinois 60o67 (847) 963-9000

I Introduction The purpose of the meteorological program being conducted at the Zion Station site is to provide information sufficient to assess the local weather conditions and to determine the degree of atmospheric dispersion of airborne radioactive effluent from the station.

The meteorological tower is 250 ft. high and is instrumented at two levels. Wind speed and direction are measured at 35 ft. and 250 ft. Ambient temperature is measured at 35 ft. Differential temperature, referenced to 35 ft., is measured at 250 ft. Dew point temperature is measured approximately ten feet from the tower at an elevation of 5 ft.

Precipitation is measured by a rain gauge located on the roof of the meteorological shelter building.

Joint frequency stability wind rose tables of wind direction, wind speed, and stability are routinely tabulated from hourly measurements. The quarterly and annual tables are included in this report.

Descriptions of the instruments and recorders are given in Section 3 (Data Acquisition) of this report. Data reduction and processing are described in Section 4 (Data Analysis).

The results given in Section 5 of this report include modeled maximum whole body doses, skin doses, organ doses based upon airborne releases, and site meteorology.

Murray& Trettel, Inc. 6o0 FirstBank Drive,Suite A Palatine,Illinois 60067 (847) 963-9000

2

2. Summary The Zion Station meteorological monitoring program produced 52,350 hours0.00405 days <br />0.0972 hours <br />5.787037e-4 weeks <br />1.33175e-4 months <br /> of valid data out of a possible 52,560 parameter hours during 2014 (365 days x 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s/day x 6 measured priority parameters), which represents an overall data recovery rate of 99.6%.

Priority parameters are all parameters except dew point temperature and precipitation.

The stability wind rose tables included in this report have been generated using the 35 ft.

wind data with the 250-35 ft. differential temperature data.

The maximum annual calculated cumulative doses resulting from airborne releases were as follows.

Zion Generating Station:

Unit 1:

gamma air dose 0.000 x 10-0 mrad beta air dose 0.000 x 10-0 mrad whole body dose 3.315 x 10-4 mrem skin dose 2.203 x 10"4 mrem organ (child bone) 3.129 x 10-3 mrem Unit 2:

gamma air dose 0.000 x 10-0 mrad beta air dose 0.000 x 10-0 mrad whole body dose 3.315 x 10"4 mrem skin dose 2.203 x 104 mrem organ (child bone) 3.129 x 103 mrem Murray & Trettel,Inc. 6oo FirstBank Drive, Suite A Palatine,Illinois 60067 (847) 963-9ooo

3

3. Data Acquisition Wind speed is measured with Teledyne Geotech model 1564 sensors and wind direction is measured with Teledyne Geotech model 1565 sensors. The wind speed sensors have a starting speed of 0.63 mph (0.28 mps), a range of 0 to 100 mph (0 to 44.7 mps), and a system accuracy of +1%. The wind direction sensors have a threshold speed of 0.7 mph (0.31 mps), a range of 0 to 5400, and a system accuracy of +50.

Ambient and differential temperatures are measured with RDF model 23789-4 sensors, and dew point temperature is measured with a Foxboro model 2781-18-CGN dewcell.

Ambient temperature is measured within the range of -40 to 120OF (-40 to 48.91C) with an accuracy of +0.50 F (+0.30C). Differential temperature is measured within the range of

-10 to 30°F (-5.6 to 16.70C) with an accuracy of +0.18 0 F (+0.100%), and dew point temperature is measured within the range of -40 to 120OF (-40 to 48.90C) with an accuracy of +2.7 0 F (+2.0°C). Precipitation is measured with a Climatronics model 100097 rain gauge. Precipitation is measured in increments of one one-hundredth of an inch with a system accuracy of +0.01" (+0.25mm).

Instrument types and locations are summarized in Table 1.

The meteorological data are collected and stored by a Microtel 4.0 data acquisition system. The Microtel measures the analog voltages of the instruments and records the digital equivalent within the range of 0 to +1 volt. The Microtel has the capability of storing 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of minute data and one week of hourly data. Data are obtained from the Microtel by a direct dial telephone hookup to an in-house computer system. Data are sampled every second.

As a backup to the Microtel, data are also recorded with a Johnson Yokogawa Corp. digital recorder (JYC DA100 data acquisition unit and Contec IPC-PT/M300(PC)WOU PC). Data are sampled every 10 seconds.

Data logger information is summarized in Table 2.

Murray & Trettel, Inc. 6o0 FirstBank Drive, SuiteA Palatine,Ilinois 6oo67 (847)963-9000

4 Table I Instrument Locations Measurement Sensor Type Location Elevation Wind Speed Teledyne Geotech 1564 Tower 250 ft.

Wind Direction Teledyne Geotech 1565 Tower 250 ft.

Differential Temperature RDF 23789-4 Tower 250 ft.

Wind Speed Teledyne Geotech 1564 Tower 35 ft.

Wind Direction Teledyne Geotech 1565 Tower 35 ft.

Ambient Temperature RDF 23789-4 Tower 35 ft.

Climatronics 100097 Meteorological Precipitation 10ft.

Tipping Bucket shelter roof Dew Point Temperature Foxboro 2781-18-CGN Instrument Shelter 5 ft.

Table 2 Data Loqqers Sampling Measurement Loager Twe Frequency Winds, Temperatures, Microtel 4.0 data acquisition system 1 sec.

and Precipitation Winds, Temperatures, Johnson Yokogawa Corp. Digital Recorder 10 sec.

and Precipitation (JYC DA100 and Contec IPC-PT/M300(PC)WOU) digital recorder Drive, Suite Bank Drive, First Bank 600 First A Palatine, illinois 60067 (847) 963-9000 Murray Trettel, Inc.

Murray& Trettel, Inc. 6oo SidteA Palatine,filinois 6oo67 (847) 963-gooo

5

4. Data Analysis The Zion Microtel is routinely interrogated to obtain hourly average data. The data are then stored in the meteorological data-base and listings of the data are generated. The data listings are examined by qualified personnel and any apparent problems are brought to the attention of the Project Manager or Meteorological Technician and the Instrument Maintenance staff.

Hourly values of wind speed, wind direction, ambient temperature, differential temperature, dew point temperature, and precipitation are obtained through measurements taken at the site. The standard deviation of wind direction (sigma) is derived. The wind direction variation is described in terms of the standard deviation of the direction about the mean direction. The Microtel computes an hourly value of wind sigma by taking the Root-Mean-Square (RMS) of the four quarter-hour wind sigma values. The quarter-hour wind sigma values are calculated directly from the one second wind direction samples during the 15 minute period.

The data base files are edited approximately once a week. Missing Microtel values are replaced with recorder values, when available. Invalid data are deleted from the data-base.

Murray& Trettel, Inc. 6oo FirstBank Drive, Suite A Palatine,Ilinois 6o067 (847) 963-9000

6 When an hourly value is missing or invalid, the numeral 999 is entered into the computer data file in the appropriate location. When the wind direction changes substantially relative to its short term fluctuations, the numeral 888 can be entered into the wind sigma location to indicate shifting winds. When the wind blows with velocities near the sensing threshold of the instrument, the numeral 777 can be entered into the wind direction, wind speed, and wind sigma locations to indicate light and variable winds.

A professional meteorologist reviews the data, calibration findings, equipment maintenance reports, and other information and determines which data are valid. Only the valid data are retained in the data base.

As a quality control measure, a monthly comparison is made of Microtel and digital recorder data. An investigation is made into the reasons for any significant differences between the sets of values.

Joint frequency stability wind rose tables of hourly data measured at the site are generated. These tables indicate the prevailing wind direction, wind speed, and stability classes measured during the period of observation as well as the joint frequencies of occurrence of the wind direction, wind speed, and stability classes. The values are also used as input to the atmospheric transport and diffusion models. Wind direction, wind speed, and stability classes are given in Tables 3, 4, and 5.

Murray & Trettel, Inc. 6oo FirstBank Drive, Suite A Palatine,Illinois 60067 (847) 963-9o00

7 Table 3 Wind Direction Classes IF 348.750 < WD < 11.250 THEN Class is N IF 11.250 < WD < 33.750 THEN Class is NNE IF 33.750 < WD < 56.250 THEN Class is NE IF 56.250 < WD < 78.750 THEN Class is ENE IF 78.750 < WD < 101.250 THEN Class is E IF 101.250 < WD < 123.750 THEN Class is ESE IF 123.750 < WD < 146.250 THEN Class is SE IF 146.250 < WD < 168.750 THEN Class is SSE IF 168.750 < WD < 191.250 THEN Class is S IF 191.250 < WD < 213.750 THEN Class is SSW IF 213.750 < WD < 236.250 THEN Class is SW IF 236.250 < WD < 258.750 THEN Class is WSW IF 258.750 < WD < 281.250 THEN Class is W IF 281.250 < WD < 303.750 THEN Class is WNW IF 303.750 < WD < 326.250 THEN Class is NW IF 326.250 < WD < 348.750 THEN Class is NNW Table 4 Wind Speed Classes IF 0.0 mph < WS < 0.7 mph THEN Class is 1 IF 0.7 mph < WS < 3.5 mph THEN Class is 2 IF 3.5 mph < WS < 7.5 mph THEN Class is 3 IF 7.5 mph < WS < 12.5 mph THEN Class is 4 IF 12.5 mph < WS < 18.5 mph THEN Class is 5 IF 18.5 mph < WS < 24.5 mph THEN Class is 6 IF 24.5 mph < WS THEN Class is 7 Murray& Trettel, Inc. 6oo FirstBank Drive, SuiteA Palatine,Illinois 60067 (847) 963-9000

8 Table 5 Atmospheric Stability Classes Differential Differential Temperature Temperature Interval Interval (in OF over the Class (in °C/1 00m) (1) 250-35 ft. interval') (2) 250-35 ft. interval)

(2)

Extremely Unstable AT -1.9 AT -2.3 Moderately Unstable -1.9 < AT -1.7 -2.3 < AT -2.1 Slightly Unstable -1.7 < AT -1.5 -2.1 < AT -1.8 Neutral -1.5 < AT -0.5 -1.8 < AT -0.6 Slightly Stable -0.5 < AT 1.5 -0.6 < AT 1.7 Moderately Stable 1.5 < AT 4.0 1.7 < AT 4.7 Extremely Stable 4.0 < AT 4.7 < AT

() from ANSI/ANS 2.5 (2) ANSI(ANS 2.5 intervals scaled for instrument heights on the Zion meteorological tower Murray& Trettel,Inc. 600 FirstBank Drive, Suite A Palatine,Illinois 60067 (847) 963-9000

9 The following two programs were used to calculate doses resulting from radioactive releases:

1. XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations (NUREG/CR-2919).

The program is based on the theory that material released to the atmosphere will be normally distributed (Gaussian) about the plume centerline. A straight-line trajectory is assumed between the point of release and all receptors.

The program implements the assumptions outlined in Section C of NRC Regulatory Guide 1.111. In evaluating routine releases from nuclear power plants, it primarily is designed to calculate annual relative effluent concentrations, X/Q values and annual average relative deposition, D/Q values.

Output from the XOQDOQ program is used as input to the GASPAR program.

2. GASPAR II: A Code System for Evaluation of Radiological Impacts Due to the Release of Radioactive Material to the Atmosphere During Normal Operation of Light Water Reactors (NUREG-0597).

GASPAR is a program written for the evaluation of radiological impacts due to the release of radioactive material to the atmosphere during normal operation of reactors. The GASPAR code implements the radiological impact models of NRC Regulatory Guide 1.109, Revision 1, for atmospheric releases. The program is used to estimate the maximum individual doses at selected locations in the vicinity of the plant.

Murray& Trettel, Inc. 600 FirstBank Drive, SuiteA Palatine,Illinois 60067 (847) 963-9oo0

10

5. Results 5.1 Instrument Maintenance The maintenance program followed during 2014 was composed of routinely scheduled visits and equipment repairs. Routine site visits were made to inspect the sensing and recording systems for proper operation. In addition, routine maintenance and calibration checks of all tower-mounted and ground level equipment were performed every 4 months. A description of the calibration and field procedures is found in the Murray and Trettel, Inc. "P1009 Procedures Manual" (October 2013).

In February, a malfunctioning rain gauge was repaired. Also in February, an obstruction light on the tower was replaced.

In March, the 35 ft. wind speed sensor was replaced due to bad readings.

In April, the 250 ft. wind direction wind vane was replaced due to damage.

In May, the 250 ft. wind direction sensor and signal conditioning card were replaced due to suspected bad readings. The removed sensor was later bench tested and was found to be in proper working order. Also in May, the annual tower inspection was performed.

In June, new mounting brackets for the temperature assemblies were installed. This was preventative maintenance due to bracket failures seen at other sites.

In October, bad readings on the 250 ft. wind direction were investigated. The cross arm was replaced due to a stripped out set screw. The wind direction sensor was also replaced. The bad readings caused some data loss.

In November, a damaged heat lamp assembly at the 250 ft. level was replaced.

No other significant problems were encountered with the equipment, and at the end of the year, no problems were evident at the site.

Murray & Trettel,Inc. 600 FirstBank Drive, Suite A Palatine,Illinois 6oo67 (847) 963-9ooo

11 5.2 Data Recovery The record of data recovery for the year is summarized in Table 6.

Table 6 Zion Site Data Recovery Summary 2014 Recovered Recovered Lost Percent Measurement Elevation Hours Percent Hours Changed Wind Speed 35 ft. 8737 99.7 26 0.3 Wind Speed 250 ft. 8731 99.7 29 0.3 Wind Direction 35 ft. 8748 99.9 12 0.7 Wind Direction 250 ft. 8638 98.6 122 1.5 Ambient Temperature 35 ft. 8748 99.9 12 0.1 Differential Temperature 250-33 ft. 8748 99.9 12 0.5 Dew Point Temperature 5 ft. 8712 99.5 48 6.3 Precipitation 10ft. 8660 98.9 100 1.4 AVERAGE* 99.6

  • average of priority parameters (all except dew point temperature and precipitation)

Valid Recovered Lost Hours Percent Hours Lower Level Joint Frequency % 8734 99.7 26 Upper Level Joint Frequency % 8624 98.4 136 Murray & Trettel, Inc. 6oo FirstBank Drive, Suite A Palatine,Illinois 6oo67 (847)963-9000

12 5.3 Summary of Billings for Equipment Repairs, Replacement Parts, and Other Work not Included in Fixed-Cost Maintenance Agreement - 2014 Description - Zion Cost January Meteorological equipment maintenance $ 556.90 Febrary Meteorological parts, materials, and contractor services 278.70 Meteorological equipment maintenance 700.85 March

-none- 0.00 April Meteorological equipment maintenance 1,995.10 Meteorological parts, materials, and contractor services 0.00 2014-2014 Heat Lamp Activation 318.60 May Meteorological equipment maintenance 1,272.00 June Meteorological equipment maintenance 420.00 July Meteorological parts, materials, and contractor services 18.65 Auaust

-none- 0.00 September Meteorological parts, materials, and contractor services 300.68 October Meteorological equipment maintenance 954.70 Meteorological parts, materials, and contractor services 0.00 November Meteorological equipment maintenance 804.70 Meteorological parts, materials, and contractor services 0.00 December Meteorological parts, materials, and contractor services 851.14 Annual Total: $ 8,472.02 Murray & Trettel, Ine. 6o0 FirstBank Drive, Suite A Palatine,Illinois 6oo67 (847) 963-gooo

13 5.4 Stability Wind Rose Data The quarterly and annual stability wind roses are given in Tables 7 through 11. Wind speed classes have been altered to reflect the wind sensor threshold.

For the year, winds measured at 35 ft. most frequently came from the West (11.98%) and fell into the 3.6-7.5 mph wind speed class (39.11%). Calms (wind speeds at or below the sensor threshold) were measured 0.06% of the time and speeds greater than 24.5 mph were measured 0.01% of the time.

Stability based on the 250-35 ft. differential temperature most frequently fell into the neutral classification (43.74%).

Murray& Trettel, Inc. 600 FirstBank Drive, SuiteA Palatine,Illinois 60o67 (847)963-9oo0

TABLE 7 Zion Nuclear Station January-March, 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

Nwiber of Obser-vations - 2154 Values are Percent Occurrence SPEED ---------------------------------- WIND DIRECTION CLASSES ---------------------------------- -------- STABILITf CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CSU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 L SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0D 0.00 MMS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1 SU 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09

-N 0.00 0.05 0.09 0.05 0.05 0.00 0.05 0.05 0.23 0.32 0.23 0.09 0.23 0.19 0.14 0.05 1.81 1.81 3 SS 0.00 0.00 0.09 0.00 0.00 0.00 0.05 0.05 0.14 0.00 0.28 0.37 0.23 0.60 0.28 0.14 2.23 2.23 MS 0.00 0.05 0.00 0.00 0.00 O.0 0.00 0.00 0.14 0.05 0.09 0.23 0.23 0.09 0.05 0.05 0.97 0.97 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.00 0.00 0.00 0.32 0.09 0.00 0.00 0.56 0.56 5.65 EU 0.00 0.00 0.05 0.00 0.00 0.00 0.19 0.05 0.00 0.00 0.09 0.14 0.05 0.05 0.00 0.00 0.60 0.60 MU0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.05 0.09 0.05 0.09 0.00 0.42 0.42 4 SU 0.09 0.28 0.05 0.00 0.09 0.14 0.09 0.09 0.05 0.23 0.23 0.32 0.14 0.37 0.19 0.09 2.46 2.46.

-N 0.19 0.37 0.19 0.14 0.14 0.19 0.14 0.46 0.97 1.86 1.16 1.53 1.90 1.72 1.67 0.42 13.05 13.05 7 SS 0.19 0.05 0.05 0.05 0.09 0.19 0.05 0.32 0.88 0.70 0.56 0.93 1.44 1.72 1.16 0.37 8.73 8.73 MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.42 0.09 0.28 0.60 0.32 0.74 0.09 0.00 2.60 2.60 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.19 0.05 0.05 0.09 0.60 0.56 0.00 0.00 1.53 1.53 29.39 EU 0.00 0.37 0.37 0.19 0.00 0.00 0.32 0.32 0.00 0.00 0.19 0.97 1.02 1.02 1.02 0.19 5.99 5.99 MU 0.05 0.09 0.05 0.05 0.00 0.00 0.09 0.09 0.00 0.14 0.09 0.42 0.14 0.37 0.46 0.23 2.27 2.27 8 SU 0.05 0.19 0.09 0.05 0.00 0.05 0.05 0.32 0.09 0.32 0.23 0.46 0.19 0.32 0.56 0.14 3.11 3.11

-N 0.88 1.39 0.65 0.28 0.23 0.37 0.23 1.72 1.16 1.16 2.00 2.92 5.43 3.20 1.86 2.46 25.95 25.95 I SS 0.14 0.23 0.05 0.00 0.23 0.14 0.05 0.23 0.51 0.65 0.19 0.42 0.65 0.46 0.46 0.00 4.41 4.41 2MS 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.14 0.28 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.56 0.56 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 42.34 EU 0.14 0.23 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28 0.42 0.46 0.23 0.32 0.00 2.27 2.27 1MUJ 0.14 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.14 0.23 0.23 0.14 0.05 0.00 1.02 1.02 3 SU 0.19 0.09 0.23 0.14 0.00 0.00 0.00 0.14 0.05 0.23 0.19 0.14 0.19 0.05 0.19 0.00 1.81 1.81

-N 0.42 0.93 1.30 0.09 0.23 0.05 0.09 1.30 0.79 2.37 1.58 1.16 1.16 0.97 0.70 0.65 13.79 13.79 1 SS 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.05 0.09 0.09 0.32 0.00 0.00 0.00 0.00 0.00 0.65 0.65 8MS 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.19 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.32 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 20.01 Murray & Trettel, Inc. 6oo First Bank Drive,Suite A Palatine,Illinois 60067 (847)963-90oo

TABLE 7 continued Zion Nuclear Station January-March. 2014 35 ft. Wind Speed and Direction 25OFt-33Ft Delta-T (F)

SPEED -------------------- ------------- WIND DIRECTION CLASSES ---------------------------------- STABILIT( CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28 0.00 0.00 0.00 0.00 0.37 0.37 1 MU 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.19 0.19 9 SU 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.09 0.00 0.00 0.00 0.00 0.32 0.32

-N 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.46 0.00 0.09 0.65 0.19 0.00 0.00 0.00 0.00 1.5B 1.58 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4 MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.55 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 GMU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T SU 0.00 O.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.05 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 TOT 2.79 4.41 3.62 1.02 1.16 1.30 1.44 6.27 6.27 8.40 9.05 11.88 15.32 13.00 9.29 4.78 100.00 9.24 3.90 7.80 56.22 16.02 4.55 2.27 100.00 Wind Direction by Stability N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -STABILITY CLASSES-0.19 0.60 0.65 0.19 0.00 0.00 0.51 0.37 0.00 0.00 0.56 1.81 1.53 1.30 1.35 0.19 9.24 Extremely Unstable 0.23 0.19 0.09 0.05 0.00 0.00 0.09 0.14 0.00 0.19 0.28 0.79 0.46 0.56 0.60 0.23 3.90 Moderately Unstable 0.37 0.56 0.46 0.19 0.09 0.19 0.19 0.56 0.19 0.79 0.79 1.02 0.51 0.74 0.93 0.23 7.80 Slightly Unstable 1.67 2.74 2.23 0.56 0.65 0.60 0.51 3.99 3.1F 5.80 5.66 5.90 8.73 6.08 4.36 3.57 56.22 Neutral 0.32 0.28 0.19 0.05 0.37 0.37 0.14 0.65 1.62 1.44 1.35 1.72 2.32 2.79 1.90 0.51 16.02 Slightly Stable 0.00 0.05 0.00 0.00 0.05 0.14 0.00 0.46 0.88 0.14 0.37 0.56 0.84 0.88 0.14 0.05 4.55 Moderately Stable 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.42 0.05 0.05 0.09 0.93 0.65 0.00 0.00 2.27 Extremely Stable Wind Direction by Wind Speed N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -WIND SPEED CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.00 0.09 0.23 0.05 0.05 0.00 0.14 0.19 0.56 0.37 0.60 0.70 1.02 0.97 0.46 0.23 5.66 < 3.5 mph 0.46 0.74 0.32 0.19 0.32 0.51 0.46 1.02 2.51 2.92 2.41 3.39 4.83 5.20 3.20 0.88 29.39 3.6 - 7.5 mph 1.11 2.27 1.21 0.56 0.51 0.60 0.74 2.83 2.09 2.27 2.69 5.20 7.43 5.43 4.36 3.02 42.34 7.6 - 12.5 mph 0.88 1.30 1.72 0.23 0."d 0.19 0.09 1.67 1.11 2.74 2.51 1.95 2.04 1.39 1.25 0.65 20.01 12.6 - 18.5 mph 0.32 0.00 0.14 0.00 0.00 0.00 0.00 0.56 0.00 0.09 0.79 0.65 0.00 0.00 0.00 0.00 2.55 18.6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 > 24.5 mph Murray & Trettel, Inc. 6oo FirstBank Drive, Suite A Palatine,Illinois 60067 (847)963-9ooo

TABLE 8 Zion Nuclear Station April-June, 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

Number of Observations - 2169 Values are Percent Occurrence SPEED ---------------------------------- WIND DIRECTION CLASSES ---------------------------------- STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 L SS 0.00 0.00 0.00 0.00 0. 10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 MMS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.18 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1 SU 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09

-N 0.05 0.37 0.28 0.18 0.32 0.23 0.05 0.05 0.09 0.00 0.00 0.00 0.05 0.05 0.23 0.09 2.03 2.03 3 SS 0.18 0.37 0.46 0.32 0.14 0.28 0.37 0.14 0.28 0.37 0.18 0.05 0.14 0.23 0.37 0.32 4.20 4.20 MS 0.37 0.23 0.28 0.23 0.37 0.23 0.23 0.23 0.41 0.51 0.23 0.37 0.23 0.37 0.32 0.28 4.89 4.89 ES 0.18 0.05 0.23 0.05 0.14 0.09 0.14 0.32 0.23 0.37 0.18 0.41 0.46 0.18 0.14 0.09 3.27 3.27 14.48 EU 0.09 0.18 0.28 0.05 0.14 0.14 0.00 0.00 0.00 0.00 0.18 U.09 0.09 0.00 0.18 0.00 1.43 1.43 MU 0.05 0.05 0.28 0.09 0.18 0.00 0.28 0.00 0.00 0.00 0.00 0.05 0.14 0.14 0.00 0.00 1.24 1.24 4 SU 0.14 0.65 0.14 0.09 0.18 0.00 0.09 0.18 0.00 0.00 0.05 0.09 0.09 0.00 0.09 0.05 1.84 1.84

- N 1.89 2.07 1.80 0.78 0.69 0.46 0.65 0.55 0.74 0.32 0.46 0.83 0.55 0.51 0.60 0.83 13.74 13.74 7 SS 0.92 1.15 0.55 0.41 0.41 0.51 0.88 1.06 1.75 1.48 0.74 0.65 0.51 0.65 0.51 0.55 12.72 12.72 MS 0.46 0.37 0.32 0.41 0.23 0.23 0.65 0.55 1.48 0.65 0.09 0.00 0.18 0.00 0.09 0.14 5.86 5.86 ES 0.05 0.00 0.09 0.14 0.23 0.14 0.37 1.01 0.97 0.18 0.05 0.09 0.23 0.05 0.14 0.05 3.78 3.78 40.62 EU 0.09 1.43 1.15 0.14 0.00 0.00 0.28 0.09 0.00 0.09 0.65 1.06 0.78 0.32 0.46 0.18 6.73 6.73 MU 0.09 0.51 0.14 0.05 0.00 0.09 0.00 0.00 0.05 0.05 0.23 0.37 0.37 0.14 0.00 0.05 2.12 2.12 8 SU 0.78 0.28 0.09 0.05 0.05 0.05 0.05 0.05 0.00 0.00 0.09 0.55 0.09 0.09 0.09 0.28 2.58 2.58

-N 2.63 1.C4 0.74 0.46 0.37 0.23 0.28 0.74 0.41 1.24 0.97 0.46 0.69 0.28 0.37 0.32 12.03 12.03 1 SS 1.01 0.28 0.23 0.14 0.05 0.09 0.46 1.38 1.20 0.32 0.28 0.14 0.14 0.09 0.09 0.05 5.95 5.95 2MS 0.14 0.09 0.18 0.18 0.09 0.14 0.18 1.15 1.29 0.05 0.09 0.00 0.00 0.00 0.05 0.00 3.64 3.64 ES 0.00 0.00 0.05 0.05 0.05 0.05 0.05 0.51 0.97 0.05 0.00 0.00 0.00 0.00 0.00 0.00 1.75 1.75 34.81 EU 0.20 0.51 0.05 0.00 0.05 0.00 0.05 0.05 0.00 0.09 0.65 0.65 0.32 0.32 0.00 0.05 3.04 3.04 1MU 0.14 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.05 0.00 0.00 0.00 0.32 0.32 3 SU 0.18 0.14 0.00 0.00 0.05 0.00 0.00 0.09 0.00 0.09 0.14 0.05 0.09 0.05 0.00 0.00 0.88 0.88

-N 0.51 0.14 0,14 0.55 0.32 0.09 0.00 0.51 0.05 0.18 0.55 0.32 0.28 0.14 0.05 0.09 3.92 3.92 1SS 0.00 0.00 0,18 0.23 0.05 0.00 0.00 0.23 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.78 0.78 86KS 0.00 0.00 0,00 0.00 0.00 0.05 0.00 0.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.37 0.37 ES 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 9.41 Murray & Trettel, Inc. 6o0 FirstBank Drive,Suite A Palatine,Illinois 6o067 (847) 963-9ooo

TABLE 8 continued Zion Nuclear Station April-June. 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

SPEED ---------------------------------- WIND DIRECTION CLASSES ------------.-.-------STABILITr CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 1MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9 SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00

-N 0.14 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.23 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 4MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 G MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 41MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOT 10.42 10.70 7.75 4.66 4.15 3.09 5.03 9.31 10.05 6.09 5.01 6.27 5.49 3.60 3.78 3.46 99.82 11.25 3.69 5.39 31.95 23.79 14.80 8.94 99.82 Wind Direction by Stability N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -STABILIT( CLASSES-0.51 2.12 1.48 0.18 0.18 0.14 0.32 0.14 0.00 0.18 1.48 1.80 1.20 0.65 0.65 0.23 11.25 Extremely Unstable 0.28 0.55 0.46 0.14 0.18 0.09 0.28 0.00 0.05 0.09 0.23 0.46 0.55 0.28 0.00 0.05 3.69 Moderately Unstable 1.11 1.06 0.28 0.18 0.28 0.05 0.14 0.32 0.00 0.09 0.28 0.69 0.28 0.14 0.18 0.32 5.39 Slightly Unstable 5.21 4.43 2.95 1.98 1.75 1.01 0.97 1.89 1.29 1.75 1.98 1.61 1.57 0.97 1.24 1.34 31.95 Neutral 2.12 1.80 1.43 1.11 0.65 0.88 1.71 2.81 3.37 2.17 1.20 0.83 0.78 0.97 0.97 0.92 23.79 Slightly Stable 0.97 0.69 0.78 0.83 0.69 0.65 1.06 2.21 3.18 1.20 0.41 0.37 0.41 0.37 0.46 0.46 14.80 Moderately Stable 0.23 0.05 0.37 0.23 0.41 0.28 0.55 1.94 2.17 0.60 0.23 0.51 0.69 0.23 0.28 0.14 8.94 Extremely Stable Wind Direction by Wind Speed N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -WIND SPEED CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.18 CALM 0.78 1.01 1.29 0.83 0.97 0.83 0.78 0.74 1.01 1.24 0.60 0.83 0.88 0.83 1.06 0.78 14.48 < 3.5 mph 3.60 4.47 3.46 1.98 2.07 1.48 2.90 3.37 4.93 2.63 1.57 1.80 1.80 1.34 1.61 1.61 40.62 3.6 - 7.5 mph 4.75 4.43 2.58 1.06 0.60 0.65 1.29 3.92 3.92 1.80 2.31 2.58 2.07 0.92 1.06 0.88 34.81 7.6 - 12.5 mph 1.11 0.78 0.41 0.78 0.46 0.14 0.05 1.24 0.14 0.41 1.34 1.06 0.74 0.51 0.05 0.18 9.41 12.6 - 18.5 mph 0.18 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 18.6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 > 24.5 mph Murray& Trettel,Inc. 6oo FirstBank Drive, Suite A Palatine,Ilinois 60067 (847)963-90oo

TABLE 9 Zion Nuclear Station July-September. 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

Number of Observations - 2204 Values are Percent Occurrence SPEED ---------------------------------- WINDDIRECTION CLASSES ---------------------------------- ......... STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU Ii SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 L SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 M MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 EU 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 MU 0.00 0.00 0.05 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.23 0.23 I SU 0.05 0.09 0.05 0.00 0.14 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.50 0.50

-N 0.32 0.41 0.32 0.32 0.18 0.41 0.27 0.18 0.32 0.09 0.23 0.09 0.23 0.18 0.32 0.27 4.13 4.13 3 SS 0.50 0.36 0.23 0.14 0.09 0.23 0.14 0.41 0.54 1.00 0.27 0.32 0.82 0.50 0.36 0.59 6.49 6.49 MS 0.18 0.05 0.05 0.05 0M00 0.09 0.00 0.09 0.50 1.86 1.59 1.27 0.64 0.32 0.68 0.50 7.85 7.85 ES 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.41 0.91 1.18 1.04 0.91 0.23 0.14 4.95 4.95 24.18 EU o.or% 0.82 2.36 1.36 1.18 1.27 1.36 0.27 0.05 0.05 0.23 0.68 0.91 0.14 0.18 0.00 10.89 10.89 MU 0.09 0.18 0.23 0.23 0.23 0.32 0.23 0.09 0.00 0.09 0.05 0.09 0.23 0.00 0.23 0.00 2.27 2.27 4 SU 0.32 0.23 0.23 0.09 0.18 0.18 0.54 0.64 0.18 0.05 0.27 0.05 0.18 0.05 0.05 0.18 3.40 3.40

-N 0.95 1.32 0.41 0.73 1.04 0.73 1.04 1.09 1.41 0.32 1.18 0.86 0.95 0.91 0.91 1.23 15.06 15.06 7 SS 0.50 0.41 0.18 0.05 0.09 0.09 0.41 0.45 2.63 0.73 0.95 1.27 0.68 0.77 0.45 0.68 10.34 10.34 MS 0.09 0.05 0.00 0.05 0.05 0.09 0.14 0.05 1.00 0.68 0.41 0.77 0.95 0.54 0.77 0.14 5.76 5.76 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.23 0.73 0.59 0.14 0.00 0.00 1.77 1.77 49.50 EU 0.50 1.27 0.36 0.18 0.00 0.14 0.14 0.50 0.05 0.14 0.45 0.59 1.13 0.45 0.05 0.05 5.99 5.99 MU 0.32 0.14 0.00 0.00 0.05 0.09 0.00 0.36 0.00 0.18 0.45 0.14 0.27 0.14 0.09 0.09 2.31 2.31 8 SU 0.36 0.32 0.05 0.00 0.00 0.05 0.09 0.64 0.14 0.05 0.32 0.45 0.14 0.14 0.14 0.23 3.09 3.09

-N 0.73 0.45 0.32 0.09 0.27 0.09 0.05 1.54 0.36 0.50 1.68 0.45 0.45 0.23 1.00 1.13 9.35 9.35 1 SS 0.09 0.00 0.00 0.00 0.00 0.00 0.05 0.50 0.82 0.32 0.27 0.09 0.09 0.05 0.05 0.09 2.40 2.40 2MS 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.23 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.41 0.41 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 23.59 EU 0.23 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.23 0.14 0.00 0.05 0.05 0.00 0.77 0.77 1 MU 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.00 0.00 0.05 0.00 0.23 0.23 3 SU 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.05 0.00 0.27 0.27

-N 0.23 0.09 0.00 0.00 0.00 0.00 0.00 0.36 0.00 0.00 0.23 0.00 0.00 0.00 0.05 0.05 1.00 1.00 I SS 0.05 0.14 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.23 8MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.50 Murray & Trettel, Inc. 6oo FirstBank Drive,Suite A Palatine,Illinois 6o067 (847)963-9ooo

TABLE 9 continued Zion Nuclear Station July-September, 2014 35 ft. Wind Speed and Direction 250Ft-?L3Ft Delta-T (F)

SPEED -------------- WIND DIRECTION CLASSES ------------.-.-------STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N S5 MS ES TOTAL EU 0.00 0.00 O.DO 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0D 0.00 0.00 0.00 0.00 0.00 1 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9 SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

- N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 4 MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 G MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 00 N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4 MS 0.00 0.00 0.00 0.00 0.00 0. O0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOT 5.72 6.44 4.81 3.27 3.54 3.95 4.54 7.40 8.35 A.58 10.03 9.26 9.44 5.49 5.72 5.40 99.95 17.70 5.04 7.26 29.54 19.60 14.07 6.76 99.95 Wind Direction by Stability N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -STABILITY CLASSES-0.177 2.13 2.72 1.54 1.23 1.41 1.50 0.77 0.09 0.23 0.91 1.41 2.04 0.64 0.27 0.05 17.70 Extremely Unstable 0.45 0.32 0.27 0.23 0.27 0.54 0.23 0.45 0.00 0.27 0.59 0.27 0.54 0.14 0.36 0.09 5.04 Moderately Unstable 0.77 0.73 0.32 0.09 0.32 0.27 0.64 1.32 0.32 0.09 0.59 0.54 0.41 0.18 0.23 0.45 7.26 Slightly Unstable 2.22 2.27 1.04 1.13 1.50 1.23 1.36 3.18 2.09 0.91 3.31 1.41 1.63 1.32 2.27 2.68 29.54 Neutral 1.13 0.91 0.41 0.18 0.18 0.32 0.59 1.54 3.99 2.04 1.50 1.68 1.59 1.32 0.86 1.36 19.60 Slightly Stable 0.32 0.09 0.05 0.09 0.05 0.18 0.18 0.14 1.72 2.59 2.00 2.04 1.59 0.86 1.50 0.64 14.07 Moderately Stable 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.14 0.45 1.13 1.91 1.63 1.04 0.23 0.14 6.76 Extremely Stable Wind Direction by Wind Speed N NNE NE ENE E ESE SE SSE S SSW SW WSW W RWNW NW NNW TOTAL -WIND SPEED CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 CALM 1.09 0.91 0.68 0.50 0.45 0.91 0.45 0.73 1.41 3.36 2,99 2.86 2.81 1.91 1.59 1.54 24.18 < 3.5 mph 2.00 2.99 3.40 2.50 2.77 2.68 3.72 2.59 5.31 1.95 3.31 4.45 4.49 2.54 2.59 2.22 49.50 3.6 - 7.5 mph 2.04 2.18 0.73 0.27 0.32 0.36 0.36 3.54 1.63 1.23 3.18 1.72 2.09 1.00 1.36 1.59 23.59 7.6 - 12.5 mph 0.59 0.36 0.00 0.00 0.00 0.00 0.00 0.41 0.00 0.05 0.54 0.23 0.05 0.05 0.18 0.05 2.50 12.6 - 18.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 18.6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 24.5 mph Murray & Trettel, Inc. 6oo FirstBank Drive, Suite A Palatine,llinois 60067 (847) 963-9000

TABLE 10 Zion Nuclear Station October-December. 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

Number of Observations - 2202 Values are Percent Occurrence SPEED ----------------------------- WIND DIRECTION CLASSES -------------------------- STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 L SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MMS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 D.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1 SU 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09

.N 0.05 0.05 0.05 0.05 0.05 0.05 0.09 0.14 0.32 0.18 0.45 0.32 0.41 0.36 0.50 0.14 3.18 3.18 3 SS 0.05 0.05 0.05 0.05 0.00 0.09 0.09 0.05 0.05 0.41 0.27 0.27 0.68 0.50 0.64 0.18 3.41 3.41 MS 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0. 0; 0.09 0.18 0.09 0.18 0.32 0.23 0.05 0.00 1.23 1.23 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.59 0. F4 0.14 0.00 0.00 1.45 1.45 9.3A EU 0.05 0.23 0.14 0.09 0.14 0.36 0.41 0.05 0.00 0.00 0.00 0.18 0.27 0.05 0.23 0.05 2.23 2.23 MU 0.00 0.09 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.09 0.14 0.09 0.09 0.05 0.05 0.00 0.68 0.68 4 SU 0.23 0.09 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.14 0.32 0.27 0.45 0.27 0.09 0.00 2.00 2.00

-N 0.73 0.27 0.14 0.05 0.18 0.27 0.45 0.41 1.77 1.18 1.36 1.73 2.32 2.72 3.36 1.68 18.62 18.62 7 SS 0.09 0.18 0.18 0.09 0.00 0.00 0.14 0.68 1.32 1.00 1.09 1.73 1.50 0.95 0.45 0.41 9.81 9.81 MS 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.50 0.09 0.27 0.18 0.27 0.23 0.32 0.05 2.00 2.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.41 0.36 0.41 0.14 0.00 1.41 1.41 36.74 EU 0.05 0.23 0.14 0.00 0.05 0.05 0.09 0.18 0.09 0.18 0.36 0.64 0.91 0.32 0.18 0.00 3.45 3.45 MU 0.18 0.05 0.00 0.05 0.00 0.05 0.05 0.23 0.14 0.27 0.45 0.23 0.50 0.41 0.05 0.14 2.77 2.77 8 SU 0.18 0.00 0.00 0.00 0.00 0.09 0.00 0.14 0.27 0.23 0.64 0.50 1.04 0.82 0.27 0.09 4.27 4.27

-N 1.36 0.23 0.32 0.14 0.32 0.36 0.68 3.13 1.82 3.54 1.82 2.36 5.00 3.18 1.95 1.86 28.07 28.07 I SS 0.00 0.14 0.05 0.00 0.05 0.09 0.09 0.86 0.95 0.41 0.77 0.32 0.18 0.09 0.00 0.00 4.00 4.00 2MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 42.55 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.27 0.91 0.09 0.05 0.00 1.32 1.32 IMUJ 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.23 0.05 0.45 0.00 0.00 0.00 0.91 0.91 3 SU 0.14 0.00 0.05 0.00 0.00 0.00 0.00 0.18 0.05 0.14 0.09 0.2.3 0.32 0.00 0.09 0.05 1.32 1.32

-N 0.77 0.18 0.00 0.14 0.05 0.00 0.00 1.32 0.05 0.54 0.86 0.77 1.04 0.36 0.41 0.41 6.90 6.90 I SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.27 0.27 8MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.D0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.72 Murray & Trettel, Inc. 6oo First Bank Drive, Suite A Palatine, llhinois 6o067 (847) 963-9ooo

TABLE 10 continued Zion Nuclear Station October-December. 2014 35 ft. Wind Speed and Direction 25OFt-33Ft Delta-T (F)

SPEED ---------------------------------- WIND DIRECTION CLASSES ------------.-.------- STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 I1MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9 SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05

-N 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.27 0.59 0.59 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.64 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 GMU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 u.00 0.00 0.00 N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOT 4.04 1.86 1.09 0.64 0.82 1.50 2.18 7.95 7.54 8.72 9.36 11.31 17.67 11.17 8.81 5.36 100.00 6.99 4.36 7.72 57.36 17.48 3.22 2.86 100.00 Wind Direction by Stability N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -STABILITY CLASSES-0.09 0.45 0.27 0.09 0.18 0.41 0.50 0.23 0.09 0.18 0.36 1.09 2.09 0.45 0.45 0.05 6.99 Extremely Unstable 0.27 0.14 0.00 0.05 0.00 0.09 0.05 0.32 0.14 0.41 0.82 0.36 1.04 0.45 0.09 0.14 4.36 Moderately Unstable 0.54 D.09 0.05 0.00 0.00 0.09 0.05 0.3G 0.45 0.50 1.04 1.00 1.82 1.09 0.45 0.18 7.72 Slightly Unstable 3.00 0.82 0.50 0.36 0.59 0.68 1.23 5.13 3.95 5.45 4.50 5.18 8.76 6.63 6.22 4.36 57.36 Neutral 0.14 0.36 0.27 0.14 0.05 0.18 0.32 1.G2 2.32 1.86 2.13 2.32 2.36 1.54 1.09 0.59 17.48 Slightly Stable 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.09 0.59 0.27 0.36 0.36 0.59 0.45 0.36 0.05 3.22 Moderately Stable 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.14 1.00 1.00 0.54 0.14 0.00 2.86 Extremely Stable Wind Direction by Wind Speed N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -WIND SPEED CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.09 0.09 0.09 0.09 0.05 0.18 0.23 0.23 0.50 0.82 0.86 1.36 2.04 1.23 1.18 0.32 9.36 < 3.5 mph 1.09 0.86 0.45 0.23 0.32 0.68 1.04 1.27 3.68 2.50 3.27 4.59 5.27 4.68 4.63 2.18 36.74 3.6 - 7.5 mph 1.77 0.64 0.50 0.18 0.41 0.64 0.91 4.54 3.27 4.63 4.04 4.04 7.63 4.81 2.45 2.09 42.55 7.6 - 12.5 mph 1.00 0.18 0.05 0.14 0.05 0.00 0.00 1.77 0.09 0.77 1.18 1.32 2.72 0.45 0.54 0.45 10.72 12.6 - 18.5 mph 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.64 18.6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00  :, 24.5 mph Murray & Trettel,Inc. 600 First Bank Drive,Suite A Palatine,Illinois 60067 (847) 963-9000

TABLE 11 Zion Nuclear Station January-Decerber. 2014 35 ft. Wind Speed and Direction 250Ft-33Ft Delta-T (F)

NLuter of Observations - 8729 Values are Percent Occurrence SPEED ----------------------------- WIND DIRECTION CLASSES ---------------------------------- STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS MS ES TOTAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 L SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 MMS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.06 EU 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 MU 0.00 0.00 0.01 0.00 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.06 0.06 I SU 0.01 0.02 0.03 0.01 0.03 0.01 0.02 0.01 0.01 0.00 0.00 0.00 0.01 0.00 0.00 0.01 0.19 0.19

-N 0.10 0.22 0.18 0.15 0.15 0.17 0.11 0.10 0.24 0.15 0.23 0.13 0.23 0.19 0.30 0.14 2.80 2.80 3 SS 0.18 0.19 0.21 0.13 0.06 0.15 0.16 0.16 0.25 0.45 0.25 0.25 0.47 0.46 0.41 0.31 4.09 4.09 MS 0.14 0.08 0.08 0.07 0.09 0.09 0.06 0.09 0.29 0.65 0.50 0.52 0.36 0.25 0.27 0.21 3.75 3.75 ES 0.06 0.01 0.06 0.01 0.03 0.02 0.05 0.10 0.08 0.21 0.29 0.55 0.62 0.33 0.09 0.06 2.57 2.57 13.46 EU 0.05 0.31 0.71 0.38 0.37 0.45 0.49 0.09 0.01 0.01 0.13 0.27 0.33 0.06 0.15 0.01 3.81 3.81 MU 0.03 0.09 0.13 0.08 0.10 0.09 0.13 0.05 0.00 0.05 0.06 0.07 0.14 0.06 0.09 0.00 1.16 1.16 4 SU 0.19 0.31 0.10 0.05 0.11 0.08 0.18 0.24 0.08 0.10 0.22 0.18 0.22 0.17 0.10 0.05 2.43 2.43

-N 0.94 1.01 0.63 0.42 0.52 0.41 0.57 0.63 1.23 0.92 1.04 1.24 1.43 1.47 1.64 1.04 15.13 15.13 7 SS 0.42 0.45 0.24 0.15 0.15 0.19 0.37 0.63 1.65 0.97 0.84 1.15 1.03 1.02 0.64 0.50 10.40 10.40 MS 0.14 0.10 0.08 0.11 0.07 0.08 0.21 0.17 0.85 0.38 0.26 0.32 0.50 0.38 0.32 0.08 4.06 4.06 ES 0.01 0.00 0.02 0.03 0.06 0.03 0.09 0.25 0.30 0.07 0.10 0.33 0.45 0.29 0.07 0.01 2.12 2.12 39.11 EU 0.16 0.82 0.50 0.13 0.01 0.05 0.21 0.27 0.03 0.10 0.41 0.81 0.96 0.53 0.42 0.10 5.53 5.53 MU 0.16 0.19 0.05 0.03 0.01 0.06 0.03 0.17 0.05 0.16 0.31 0.29 0.32 0.26 0.15 0.13 2.37 2.47 8 SU 0.34 0.19 0.06 0.02 0.01 0.06 0.05 0.29 0.13 0.15 0.32 0.49 0.37 0.34 0.26 0.18 3.26 3.26

- N 1.40 0.97 0.50 0.24 0.30 0.26 0.31 1.79 0.94 1.62 1.62 1.55 2.89 1.72 1.29 1.44 18.83 18.83 1 SS 0.31 0.16 0.08 0.03 0.08 0.08 0.16 0.74 0.87 0.42 0.38 0.24 0.26 0.17 0.15 0.03 4.18 4.18 2MS 0.05 0.02 0.05 0.05 0.03 0.05 0.06 0.32 0.45 0.02 0.02 0.00 0.00 0.01 0.02 0.00 1.15 1.15 ES 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.13 0.26 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.46 0.46 35.79 EU 0.16 0.19 0.06 0.00 0.01 0.00 0.01 0.01 0.00 0.03 0.29 0.37 0.42 0.17 0.10 0.01 1.84 1.84 1IMU 0.10 0.01 0.01 0.00 0.00 0.00 0.00 0.01 0.00 0.03 0.11 0.09 0.18 0.03 0.02 0.00 0.62 0.62 3 SU 0.14 0.08 0.07 0.03 0.01 0.00 0.00 0.10 0.02 0.11 0.10 0.11 0.16 0.02 0.08 0.01 1.07 1.07

- N 0.48 0.33 0.36 0.19 0.15 0.03 0.02 0.87 0.22 0.77 0.80 0.56 0.62 0.37 0.30 0.30 6.37 6.37 1SS 0.01 0.03 0.05 0.06 0.02 0.01 0.00 0.14 0.05 0.03 0.08 0.00 0.00 0.00 0.00 0.00 0.48 0.48 8MS 0.00 0.00 0.00 0.00 0.00 0.03 0.00 0.11 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.17 0.17 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.003 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.06 10.61 Murray& Trettel, Inc. 600 FirstBank Drive,Suite A Palatine,MIlinos 60067 (847) 963-9ooo

TABLE 11 continued Zion Nuclear Station January-December. 2014 35 ft. Wind Speed and Direction 25OFt-33Ft Delta-T (F)

SPEED ---------------------------------- WIND DIRECTION CLASSES ........

- STABILITY CLASSES ----------

CLASS N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL EU MU SU N SS RS ES TOTAL EU 0.02 0.00 0.01 0.00 0.00 0.00 O.00 0.00 0.00 0.00 0.00 0.07 0.00 0.00 0.00 0.00 0.10 0.10 1MU 0.01 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.05 0.05 9 SU 0.01 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.02 0.00 0.00 0.00 0.01 0.09 0.09

-N 0.10 0.02 0.00 0.00 0.01 0.00 0.00 0.16 0.00 0.02 0.16 0.05 0.00 0.00 0.00 0.07 0.60 0.60 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 4 M 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.91 EU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 G MU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 N 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.01 0.01 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4MS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O.nO 0.00 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 TOT 5.74 5.84 4.31 2.39 2.42 2.46 3.30 7.73 8.05 7.45 8.57 9.68 11.98 8.31 6.90 4.75 99.94 11.31 4.25 7.05 43.74 19.22 9.16 5.21 99.94 Wind Direction by Stability N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -STABILIT( CLASSES-0.39 1.33 1.28 0.50 0.40 0.49 0.71 0.38 0.05 0.15 0.82 1.52 1.72 0.76 0.G8 0.13 11.31 Extremely Unstable 0.31 0.30 0.21 0.11 0.11 0.18 0.16 0.23 0.05 0.24 0.48 0.47 0.65 0.36 0.26 0.13 4.25 Moderately Unstable 0.70 0.61 0.27 0.11 0.17 0.15 0.25 0.64 0.24 0.37 0.68 0.81 0.76 0.54 0.45 0.30 7.05 Slightly Unstable 3.02 2.55 1.67 1.01 1.12 0.88 1.02 3.55 2.62 3.47 3.86 3.52 5.17 3.75 3.53 2.99 43.74 Neutral 0.93 0.84 0.57 0.37 0.31 0.44 0.69 1.71 2.83 1.88 1.55 1.64 1.76 1.65 1.20 0.85 19.22 Slightly Stable 0.32 0.21 0.21 0.23 0.19 0.25 0.32 0.72 1.59 1.05 0.79 0.84 0.86 0.64 0.62 0.30 9.16 Moderately Stable 0.07 0.01 0.09 0.06 0.10 0.07 0.15 0.50 0.68 0.29 0.39 0.88 1.07 0.62 0.16 0.07 5.21 Extremely Stable Wind Direction by Wind Speed N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNWTOTAL -WIND SPEED CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.06 CALM 0.49 0.53 0.57 0.37 0.38 0.48 0.40 0.47 0.87 1.45 1.27 1.44 1.70 1.224 1.08 0.72 13.46 -" 3.5 mph 1.79 2.27 1.91 1.23 1.37 1.34 2.04 2.06 4.11 2.50 2.65 3.56 4.10 3.44 3.01 1.73 39.11 3.6 - 7.5 mph 2.42 2.37 1.25 0.E2 0.44 0.56 0.82 3.71 2.73 2.49 3.06 3.38 4.80 3.04 2.30 1.89 35.79 7.6 - 12.5 mph 0.89 0.65 0.54 0.29 0.19 0.08 0.03 1.27 0.33 0.99 1.39 1.13 1.39 0.60 0.50 0.33 10.61 12.6 - 18.5 mph 0.15 0.02 0.03 0.00 0.01 0.00 0.00 0.22 0.01 0.02 0.19 0.16 0.00 0.00 0.00 0.08 0.91 18.6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.01 > 24.5 mph Murray & Trettel,Inc. 6oo FirstBank Drive, Suite A Palatine,Illinois 6o067 (847)963-9000

24 5.5 Precipitation Monthly totals and the maximum 24-hour and maximum 1-hour precipitation amounts are summarized below. The month with the most measured precipitation was June*. The month with the least measured precipitation was December. The maximum 24-hour total was 1.98" (May) and the maximum 1-hour total was 1.09" (May).

Table 12 PrecipitationTotals (Inches) - 2014 Zion Site Maximum Maximum Month Total 24-hour 1-hour January 1.19" 0.80* 0.19*

February 2.08* 1.57" 0.40*

March 0.97* 0.34* 0.10*

April 3.79 0.95 0.40 May 5.79 1.98 1.09 June 5.81* 1.64* 0.39*

July 1.62 0.57 0.33 August 4.10 1.76 1.00 September 4.01* 1.38* 0.77*

October 3.33 1.22 0.44 November 1.30* 0.83* 0.13*

December 0.54 0.28 0.07 TOTAL: 34.53*

  • some data are missing - actual precipitation may be under-reported Murray & Trettel, Inc. $ 6oo FirstBank Drive,Suite A $ Palatine,Illinois $ 6o067 W (847) 963-9000

25 5.6 Doses Resulting from Airborne Releases The following are the maximum annual calculated cumulative offsite doses resulting from Zion Generating Station airborne releases.

Zion Generating Station:

Unit 1 Sector Dose Maximum Value Affected gamma air (1) 0.000 x 10-0 mrad beta air (2) 0.000 x 10-0 mrad whole body (3) 3.315 x 10-4 mrem East skin (4) 2.203 x 10"4 mrem East organ (8)(child bone) 3.129 x 10-3 mrem East Unit 2 Sector Dose Maximum Value Affected gamma air (1) 0.000 x 10-0 mrad beta air (2) 0.000 x 10-0 mrad whole body (3) 3.315 x 104 mrem East skin (4) 2.203 x 10-4 mrem East organ (6)(child bone) 3.129 x 10-3 mrem East (1) Gamma Air Dose - GASPAR II, NUREG-0597 (2) Beta Air Dose - GASPAR II, NUREG-0597 (3) Whole Body Dose - GASPAR II, NUREG-0597 (4) Skin Dose - GASPAR II, NUREG-0597 (6) Inhalation and Food Pathways Dose - GASPAR II, NUREG-0597 Murray & Trettel, Inc. 0 600 FirstBank Drive, SuiteA 0 Palatine,IllinoisD 6o067 W(847) 963-9000

26 APPENDIX Murray & Trettel, Inc. D 6oo FirstBank Drive,Suite A 0 Palatine,Illinois 0 6o067 0 (847) 963-9000

Exelon Contract Number 455465 B4 10/13 Zion Meteorological Calibration R-29 Page 1 of 5 Date: 2Z~z -I POWER SUPPLIES

+12.0O0V + 0.120V -12.OOOV

  • 0. 120V A:+ -Lo*

V A: -J DO' V B:+ (2O 50 V B: - 0'-( V Signal conditioners and Digital Recorder:

Sinnal Conditionar Voltage Out QlWigital recorder AF AL AL EQUIV AF AL Recorder 5 ft.

DP LO -L . -V -Z._4 AL EQUIV + 0.1"F q 1.I'A6 DPHI _____V _ __ lOJ17, AL EQUIV+ 0.1OF DPHI-LO,'2*-1_V - V 1.000V +/- 0.025V 10 ft .1 PRCP LO, 000 V .OC) V 0-04) 0 . DO a - f, o.OOOV +/- 0.050v AL EQUIV_+0.01" PRCPHI 1.0127 V (.0o V /'I00 I .OOOV: 0.050V AL EQUIV + 0.01" 35 ft WS LO .o0Q& V V O.__mph O-( mph " mph 0.006V

  • 0.005V AL EQUIV+/- 0.1mph WS HI ?2-A' V .,.30 V ____mph mph "" mph 0.300V +/- 0.005V AL EQUIV +/- 0.1mph WD LO LoO- V - V __--__ 1O o o0 0.000V +/- 0.005V AL EQUIV+ 10 WD HI ___

, V 1.000 v S*0 o -13.i a - 0 1.000V i 0.005V AL EQUIV +/- 10 TLO - L__-V IIV.-t 0 - 0 AL EQUIV + 0.10 F

- v Ilt,(,t* o THI j9LlS V AL EQUIV + 0.1°F T HI-LO 180 - .v

.V 0.781V + 0.002V 250 ft.

WS LO , V - V ).-(,P mph 0. 6 mphf " mph 0.006V +/- 0.005V AL EQUIV +/- 0.1mph WS HI ,300 V "3 0D. mph 30.0 - mph - mph 0.300V +/- 0.005V AL EQUIV + 0.1mph

__o - o WD LO 01V vV -qo0L-A___ 0.000V +/- 0.005V AL EQUIV+ 10 WD HI i. Obo V 1.000V + 0.005V AL EQUIV + 10 L9 0 T LO v -IO ,-/, 0 AL EQUIV + 0.1OF

___V THI 110,50 o 0 AL EQUIV + 0.10 F

___V T HI-LO V 0.781V +/- 0.002V it. 00 - 0 0.O00V +/- 0.010V AL EQUIV + 0.10 F T ZERO 10). z- o 0

AT SPAN __V ___V ___ ° 0.500V +/- 0.01OV AL EQUIV + 0.1OF AT MID .2* 1 v 0.250v +/- 0.005 MAt,T-59t0 4 Murray & Trettel, Inc. 600 Frst Bank Drive, Suite A -Palatine, Illinois - 60067 2 (847) 963-9000

Exelon Contract Number 455465 B5 10/13 Zion Meteorological Calibration R-29

°L- 2z7 "I* Page 2 of 5 Date:

Dates of Last Wind Sensor Bearing Replacements:

35 ft. 250 ft, (6 mos.) Wind Speed: 10 3-

.. ((  :. -l'b (12 mos.) Wind Direction: 2. ", & Ž-'2e 13 TOWER MEASUREMENTS O/"AmIent [0 Ice Bath Temperatures 35 ft. Amb. 250 ft. AT 5 ft. dewDooin AF AL AF AL AF AL Measured A7, qO oF 0F - Z. Ob FF O to, 0 F O-F Recorded __-___F F - OFF-Z1 _ F_!?, 0 OF oF Difference Oo-0 oF _-__F 0 I-1 F __. ,0 OF - OF Specification +/-0.50F *0.18 0F +/-2.70 F Winds 35 ft, 250 ft, AF AL AF AL Specification WS stall j.(U mph - mph D-( mph ___mph 0.6mph i 0.45mph Forw. WD 0 a 0 - 0 1500l5100 +/- 50 Revr. WD .397 0 - 0 36 0 - 0 3300 +/- 50 Tracking/wear 0 1-35 ft. 250 ft.

Aspirators: _ _ 014.

Comments:

Muray & Tttc Inc. 600 Fint Bank Drive, Suite A . Palatine, iinis . 60067 3 (847) 963-9000 "

Exelon Contract Number 455465 B6 10/13 Zion Meteorological Calibration R-29 Page 3 of 5

) Date: 2-zZ- N Operation of De-ice Heat Lamp System (Aug-Mar): ,9 UPS Check: 64_

Operation of Rain Gauge:-*

TipsPoured 2.6 Tips Recorded 2-5* A4-rifi I~f.,',Av " --

Debris screen: In 6 Installed Removed Tower Lighting Good Fair Poor Tower Condition Good Fair Poor Beacon 11 0D 0- Paint . 2 0: 0"1 Side lights .8 0 0 Wiring O 0 Flasher El 0] 0-' Shelter condition E 0] 0D Note: Calibration Instruments: Next Cal Due AF = As Found Psychrometer -SN- S f"T lDq 0' 'iIL Zi, AL = As Left Digital multimeter - S/N - Cui J .2.*."

= No Change (AF=AL) Digital multimeter - S/N -

Digital thermometer - S/N -

FS = Full Scale Technicians: MICLL $4 .o)ii4 , k4Ji( Itdf-x ,

Comments:

$1c 6A. e 6o-7 ,40 1IUe, r. S O  ?,YS0 1 ev &Q/W 7

&, P LLvtO 1 I- 74 ,$lL', - P J~u 12o7k is 711-hI 0/,jI Aw,1 I-1)a Murray & Trettel, Inc. *600 Flut BanIk Drie,Suite A . Palarine,Illinois - 60067 3 (847) 963.9000

Exelon Contract Number 455465 B7 10/13 R-29 Page 4 of 5 System Response Check Date:__________

Site: Zion System: Microtel Low Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 10.0 +/-0.4 10.0 +/-0.4 54:t2 54 +/-2 -24.00 +/-0.5 -6.00 +/-0.18 -24.0 +/-0.5

Response

As Found Response _ _ _ _ _ _ ___- __ -__- -5!35 As Left - - - . -

Response I Mid Scale 3 WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 50.0 +/-0.4 50.0 +/-0.4 270 +/-2 270 +/-2 40.00 +/-0.5 10.00 +/-0.18 40.0 +/-0.5 Response .....

As Found Response c. 2_.L, "1 ,C, k.e)

-- 39 ,

As Left = - -

Response

Full Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 90.0 +/-0.4 90.0 +/-0.4 486:+/-2 486+/-2 104.00 +/-0.5 26.00 +/-0.18 104.0 +/-0.5

Response

As Found T, (,.f 5 03.(oV ,b3.

Response

As Left Response --

Murar & Trete, Inc. 600 First Bank Duivte, Suite A

  • Palatine., Ifirb
  • 60067 '2 (847) 963-9000

Exelon Contract Number 455465 B8 10/13 R-29 Page 5 of 5 System Response Check Date: -&-2-6' H(

Site: Zion System: Process Computer Low Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140

_Check_ 35'WS 35'WD 250'WS 250'WD 35'T 250' AT Precipitation Expected 10.0 +/-0.4 54:+/-2 10.0 +/-0.4 54 +2 -24.00 +/-0.5 -6.00 +/-0.18 0.10 -0.01

Response

As Found Response I,",2.1. -. " -s- -.

As Left - _ - .

Response ..

Mid Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Check 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 50.0 O0A4 270:+/-2 50.0 +/-0.4 270 +/-2 40.00 +/-0.5 10.00 +/-0.18 0.50 +/-0.01 Response ..

As Found Response -57) zJA, 5Z,,.2- 3.q( 0&.O, As Left -

Response

Full Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Check 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 90.0:+/-0.4 486 +/-2 90.0:+/-0.4 486 +/-2 104.00 +/-0.5 26.00 0.18 0.90 +/-0-01 Response .......

As Found Dd25 ZJ9.-)ý Response ___ .____" . .- I -'. ________

As Left - ..-

Response

A 3 5 MunnM & Tictwk Inc. - 600 First Bank Drnue, Suite A - Patatine,lrnots - 6006729(847) 963-9000

Exelon Contract Number 455465 B4 10/13 Zion Meteorological Calibration R-29 Page 1 of 5 POWER SUPPLIESDte

+112.000V

  • 0.120V -12.OOOV +/- 0.120V A:+ /2.OZ " V A: - /P,?,30 V B: + 17Z -0 "t5 V B: -//.q i _V Signal conditioners and Digital Recorder.

Slanal Conditioner Voltaae Out ,

D r--)laital recorder Soecifications AF AL AL EQUIV AF AL Sianal Cond. Recorder 5 f t.

DP LO 0 OUP V vv'i 2 51,- 4.4 .55o -

AL EQUIV + 0.1OF ta7 4*/. .

DP HI __9.3._LV ORI(~ AL EQUIV_+0.1OF DP HI-LOI.' 0 __ V ___V 1.OOOV +/- 0.025V 10 ft PRCP LO.pOO V - V O.OC 0.000V +/- 0.050V AL EQUIV + 0.01" ICz z>0 N

.D49 V 0-i> ,,

PRCPHI, L, V ¶.OOOV +/- 0.050V AL EQUIV + 0.01" 35 ft WS LO _____V oJ(amph 0, (,- mph mph 0.006V +/- 0.005V AL EQUIV + 0.1 mph WS HI __ V 30-ý_mph ",4 3 mph mph "0.300V +/- 0.005V AL EQUIV + 0.1mph WD LO - 0 0 O.OOOV +/- 0.005V AL EQUIV + 10 WD HI v3 v- 1 -6 e 0 -

1.000V + 0.005V AL EQUIV + 10

___o ___

T LO AL EQUIV+ O,1IF 1'43 v V T HI - j/1LIL2 AL EQUIV + 0.10 F T HI-LO __v 0.781V + 0.002V 250 ft.

WS LO , OLY V 0-4-' mph_- mph

.3-E V _, b mph 0.006V +/- 0.005V AL EQUIV + 0.1 mph WS HI .*3o- V )0,1) mpht mph 0.300V +/- 0.005V AL EQUIV + 0.1 mph WD LO , 0O_ V 0 a V 0 0.OOOV +/- 0.005V AL EQUIV+/- 10 WD HI L. -00 V - v 45qo _ gl*-q 0 o-- 1.000V +/- 0.005V AL EQUIV + 10

,,v -r .3 -t o 5V - 0 TLO . 1__ V AL EQUIV +0.1 0 F

_ v(I*.*_,t o THI '3?2.V AL EQUIV + 0.1°F T HI-LO 1cI_ V ______V 0.781V +/- 0.002V T

ZERO'. Onl -V -8oeD V/b' 1b. o/D. o00 0.000V +/- 0.01 OV AL EQUIV+ 0.1 0F

.50e-> V fD.,0 . (0. 00 o ,.

  • ,r SPAN* 5" t' V 0 0.500V +/- 0.010V AL EQUIV + 0.1 0F 0" v U-00 0 ATMID Z 5-0 V 0.250v +/- 0.005 Murray & Tretel., Inc. 600 FiRt Bank Drive, Sute A . Palatine, llinois
  • 60067 3 (847) 963.9000

Exelon Contract Number 455465 135 10/13 Zion Meteorological Calibration R-29 Page 2 of 5 Date: 6 .-Iq Dates of Last Wind Sensor Bearing Replacements:

35 ft. 2.50 ft, (6 mos.) Wind Speed: q'15 1'4 -- - g. Iq (12 mos.) Wind Direction: 1Z.-3-3 5- M- I'q TOWER MEASUREMENTS 1_Ambient [ Ice Bath Temperatures 35 ft. Amb. 250 ft. AT 5 ft. dewpoint AF AL AF AL AF AL Measured 5 'I{°F_ FO,___F 0_ T__,F 0 -0o0F O---

F Recorded SD+/-UL0F __ ._F 0).) °F -- OF L/p.°)F - F Difference Ai I OF -- 'F ) 0OF . - 0 F 2,0 OF OF Specification +/-0.50F +/-0.18 0F +/-2.7F Winds 35 ft. 250 ft.

AF AL AF AL Specification WS stall V [(P mph -____mph 0, bmph __ mph 0.6mph +/- 0.45mph Forw.D 0 1500/5100+/-50 Revr. WD - o _- 0 3300+/- 50 Tracking/wear (,1<

35 ft.

Aspirators:

Comments:

Mw'ray & Trettel.e inc. 600 Rnr Banec D~ihe, State A. Pal/a~ne, Iilrinois. 600672* (847) 963-9000

Exelon Contract Number 455465 B8 10113 Zion Meteorological Calibration R-29 Page 3 of 5 Date: L,'JP Operation of De-ice Heat Lamp System (Aug-Mar): _,WA UPS Check: 4L Operation of Rain Gauge: 01'-

Tips Poured ' Tips Recorded ""

Debris screen: (iOut Installed Removed Tower Liahtina Good Fair Poor Tower Condition Good Fair Poor Beacon 0'E l E- Paint 0 E -l Side lights 1] El Wiring El El 1-Flasher El E E" Shelter condition 0- El-Note: Callbration Instruments: Next Cal Due AF = As Found Psychrometer -SIN- Jvr-V &V'C2TŽ(q AL = As Left Digital multimeter - S/N - 93 6 ?_D2r2 N .' 2, ' 5,

- =- No Change (AF=AL) Digital multimeter - S/N -

Digital thermometer - SiN -

FS = Full Scale Technicians: RekTgd_ Cq0 s, rbe.L.. #woi,.4 ,___________

Comments:

LrIA 00 Ile- VSk Signature: ___ __ __ _

Mr'ray & Trettel, Inc.

  • 600 First Bank DWw, Suite A Palatine,IUinos - 6006?7 V (847) 963.9000

Exelon Contract Number 455465 B7 10113 R-29 Page 4 of 5 System Response Check Date:d- /

Site: Zion System: Microtel Low Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' &T 5' DP Check Expected 10.0 +/-0.4 10.0 +/-0.4 54 +/-2 54 +/-2 -24.00 +/-0.5 -6.00 +/-0.18 -24.0 +/-0.5

Response

As Found Response _ 9 __ SY__ _ _ -_/_- Lf _,_____ - Ž9-f/

As Left -- -

Response

Mid Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check _______ ______________ _______ _______

Expected 50.0 +/-0.4 50.0 +/-0.4 270 +/-2 270+/-2 40.00 +/-0.5 10.00 +/-0.18 40.0 +/-0.5 Response _

As Found Response L (b, 27o Z'2 o /0-.

As Left Response...

Full Scale 3 WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 90.0 +/-0.4 90.0 +/-0.4 486+/-2 486 +/-2 104.00 *0.5 26.00 +/-0.18 104.0 +/-0.5

Response

As Found Response V, .- Je)3.- -7 As Left

Response

Muffay & TretteZ, Inc. - 600 Fi73 t Bankc Difte, Suite A - Palatine, Illinois - 60067 9(847) 963-9000

Exelon Contract Number 455465 B8 10/13 R-29 Page 5 of 5 System Response Check Date: G-(L- 1"'

Site: Zion System: Process Computer Mid Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Chek 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 50.0 +/-0.4 270 +/-2 50.0 -0.4 270;+/-2 40.00 +/-0.5 10.00 +/-0.18 0.50 +/-0.01

Response

As Found Response oIf7.Z'0 1 As Left pResonse Full Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Check 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 90.0 +/-0.4 486:12 90.0 +/-0.4 4868L2 104.00 +/-0.5 26.00 +/-0.18 0.90 +/-0.01

Response

As Found Response I, 18 LI7 S 9 0, I3 DA -),q 2L.*0 2L-. 0 As Left _ -

Response

Mwf'ay & Trett4, Inc.

  • 600 FiatBank Driw, Suite A. Palatine,Illinois. 60067 V (847) 963-9000

Exelon Contract Number 455465 B4 10113 Zion Meteorological Calibration R-29 Page 1 of 5 Date:

POWER SUPPLIES

+12.OOOV +/- 0.120V -12.OOOV +/- 0.120V A: + 0-3c) _V A:- o3C V B:+ 'A.oV B:- I*, 9 v Signal conditioners and Dlgtal Recorder:

RinnI (vnndifinner vM,,u, vv,.--..w..--

Voltnan Out

  • -- v--.

D)iaital recorder Scecifications AF AL AL EQUIV AF Al Sianal Cond. Reoorder 5 ft. 0 "0r DPLO -"A~N V AL EQUIV_+0.10 F DPHHI 9" v __ v i17 .(v AL EQUIV_+0.10 F DP HI-LO - -JR1V V 1.OOOV +/- 0.025V 10 f t II PRCP LO [o> V S v _0 _ .

0.w - .

O.OOOV

  • 0.050V AL EQUIV + 0.01" PRCPHI 9q

" V v___ 1.06_'

1.000V

  • 0.050V AL EQUIV_+0.01" 35 ft

,o 5' v *JL,, .V - mph J.(V mph4_- mph WS LO 0.006V

  • 0.005V AL EQUIV + 0.1mph WS HI _____V3L)O mph 73,
  • mph4 mph O.300V
  • 0.005V AL EQUIV+ 0.1mph

, 00,% v . )Dz*t V ° 0 -

ND LO 0.OOOV

  • 0.005V AL EQUIV+ 10 AfD HI ,qqi v - M..*o - ° I .000V +/- 0,005V AL EQUIV 1V

=--v

_____V .7.6 r LO ___ v -13Zi.'1 - 0 AL EQUIV_+0.1OF

,Igle v

'HI v AL EQUIV+ 0.11F

.791 v

"-HI-LO 0.781V +/- 0.002V 250 ft, VSLO 'VbAj V "-_V _Q mph ý,6 mph_- mph 0.006V

  • 0.005V AL EQUIV + 0.1mph VSHI ____"V .3W-) V _30' mph 0t- mph - mph 0.300V
  • 0.005V AL EQUIV + 0.1mph V 0 iDLO *___V 0 0.OOOV
  • 0.005V AL EQUIV + 10

- V 0 0 0

/DHI ),Vc.c) V 1.000V

  • 0.005V AL EQUIV+ 10

-)4, We .

LO _L!ýE__v AL EQUIV + 0.1°F HI

  • kq) v AL EQUIV+ 0.10 F

--=v 0 0 HI-LO *- 1'1A' V _- V -_._ 0.781V +/- 0.002V

.IRO 0c*0 V 0.000V +/- 0.010V AL EQUIV+ 0.1 OF

-* vf/c..&4° IO*oo- 0

'SPAN,5*c' V 0.500V + 0.01 OV AL EQUIV+ 0.1OF V * °

- MID . VV 0.250v + 0.005 Am 14-,w N Murmy Tietl, Inc. 600 First Bank Drive, Suite A . Palatine,Iinowis. 60067 3 (847) 963.9000

Exelon Contract Number 455465 B5 10/13 Zion Meteorological Calibration R-29 i- It. Page 2 of 5 Date: ,'" '"

Dates of Last Wind Sensor Bearing Replacements:

35 ft. 250 ft.

(6 mos.) Wind Speed: -I -114 -/

(12 mos.) Wind Direction: fn- 17'- i? 5- ho-1 TOWER MEASUREMENTS Ambient -I B Temoeratures 35 ft. Amb. 250 ft. AT 5 ft. dewDofnt AF AL AF AL AF AL Measured _____F - 1.75 °F O____F -"- F 51 oF oF Recorded 574 F - oF -i,'81 oF - oF 4 oF - oF Difference (9, QF _ OF 0,0 °F - oF _

. __F - F Specification +/-0.5 0F +/-0.18 0 F +/-2.7TF Winds 35 ft. 250 ft.

AF AL AF AL SDecification WS stall .QA mph 0".__mph _.Q-je.mph 0 -(a mph 0.6mph +/- 0.45mph Forw. WD 1,5D - 0 1 150 o 1500/5100o50 Revr. WD0 0 oo 32)0 3300 50 Tracking/wear K 3250 ft.

Aspirators: b Comments:

rd3'medkCV J '

Murray & Tettei, Inc. 600 Fint Bank Drie, Suit A. Palatie, Illinois . 60067 V (847) 963-9000

Exelon Contract Number 455465 83 10/13 Zion Meteorological Calibration R-29 Page 3 of 5 Date: /D. I9 4 Operation of De-ice Heat Lamp System (Aug-Mar): X See Co i-ne*'a-  ?"cI

  • Z.

UPS Check: OIL-Operation of Rain Gauge: D1<

Tips Poured 6 Tips Recorded 6-Debris screen: 5) Out Installed Removed Tower Liphtinq Good Fair Poor Tower Condition Good Fair Poor Beacon [a El 0l Paint f 0 E Side lights 0 El El Wiring 0El0 El Flasher El E] El Shelter condition D 0' E Note: Calibration Instruments: Next Cal Due AF = As Found Psychrometer - S/N - 1.71 b(.

AL = As Left Digital multimeter - S/N - I OI &'- W Ml7 0(*

-- = No Change (AF=AL) Digital multimeter - S/N -

Digital thermometer - SIN -

FS = Full Scale Technicians: (eme CI 631*"/b4L, , tL*t_-, eI4 Comments:

Signature:

Murray & Trettel, Inc. *600 First Bank Drive, Suite A Palatine,Ninois . 60067 2 (847) 963-9000

Exelon Contract Number 455465 B7 10/13 R-29 Page 4 of 5 System Response Check Date: 10 L/

Site: Zion System: Microtel Low Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 10.0 +/-0.4 10.0 +/-0.4 54 +/-2 54 +/-2 -24.00 +/-0.5 -6.00 +/-0.18 -24.0 +/-0.5

Response

As Found .5 Response _ 9__ " ~ 1~~. Q~

As Left Response _ _ ____ ___

Mid Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Check Expected 50.0 +/-0.4 50.0 +/-0.4 270+/-2 270+/-2 40.00 +/-0.5 10.00 +/-0.18 40.0 +/-0.5

Response

As Found Response _.

As Left -

Response -

Full Scale 35' WS 250' WS 35' WD 250' WD 35' T 250' AT 5' DP Expected 90.0 +/-0.4 90.0 +/-0.4 486 +/-2 486+/-2 104.00 10.5 26.00 +/-0.18 104.0 +/-0.5

Response

As Found Response 1 0' _ _ ___ _ _ C3' As Left

Response

Mwiay & Tetwel Inc.

  • 600 Fint Bank Drive, Suite A- Palatine, Ilinois - 60067 2 (847) 963.9000

Exelon Contract Number 455465 B8 10/13 R-29 Page 5 of 5 System Response Check Date: lo "I-/,--I Site: Zion System: Process Computer Low Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Check 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 10.0 +/-0.4 l 54 +/-2 10.0 +0.4 54+/-t2 Response I.. -24.00

.. +/-0.5 -6.00 t0.18 0.10 +/-0.01 As Found Response __ _ _ _ _ _ '3-*Z As Left . .----- -

-Response ________ ________

Mid Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140

-heck 35' WS 35' WD 250' WS 250' WD

  • 35' T 250' AT Precipitation Expected 50.0 +/-0.4 270*+/-2 50.0 +/-0.4 270 +/-2 40.00 +/-0.5 10.00 -0.18 0.50 +/-0.01 As Found Response
  • Z-C .b*. .5Th13* . - 6 *"lC -

Response

Full Scale Y9131 Y9132 Y9135 Y9136 Y9137 Y9138 Y9140 Check- 35' WS 35' WD 250' WS 250' WD 35' T 250' AT Precipitation Expected 90.0 +/-0.4 486 +/-2 90.0 +/-0.4 486 L2 104.00 +/-0.5 Response .. . .. 26.00 +/-0.18 0.90 +/-0.01 As Found

-*Resp onse' '45*!S 10-2-3 C ....65 2s-qý. . .6

Response

513Z + Y cr/3-7 Me4co Ive--, (-v'eXEA1-1 CAA,05 MwTay & TaekIn, Ic - 600 Fint Bank Drive Suit A. Palatine, Inois - 60067 2 (847) 963-9000

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 6 - Errata data There are no errata corrections from prior years reports in 2014

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 7 - Changes to Zion Station Liquid Radwaste System Summary: Changes to the ODCM to support the design changes to the liquid radwaste system were performed in 2013. These design changes were submitted in the 2013 Annual Radioactive Effluent Release Report. The physical changes to the system were implemented in 2014.

The changes made to the system utilize most of the in-place piping and tanks, two pillow tanks have been installed to support processing of liquid waste through the pre-existing filters and demineralizers. There are no changes made to the methodology or equipment used to reduce radioactive effluent concentration in liquid effluent. Figure 1 shows the simplified one line diagram of the system.

Overview of system operation: Liquid radwaste is stored in the 498,000 gallon Refueling Water Storage Tank (RWST) (pre-existing). From the RWST, the liquid is transferred to one of three 128,000 gallon Hold Up Tanks (HUT)(pre-existing). When a batch release is desired to be performed, water from the HUTs are pumped to one of two 25,000 gallon pillow tanks (newly constructed). Once in the pillow tanks, water is sent through the charcoal filters and demineralizers to reduce the effluent concentration and other particulates that may be present in the water. Demineralizer inlet and outlet sampling is performed to test the effectiveness of the demineralizer and predict when filters and resins will need to be changed. If desired, from the pillow tanks, water may be sent through the demineralizers multiple times. After sending the water through the demineralizers, the water is then sent to one of two 25,000 gallon Lake Release Tanks (LRT) (pre-existing and previously named Boric Acid Tanks). Water in the LRTs is then recirculated 3 times within a 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> period per ANSI standards for representative sampling. A sample is drawn, isotopically analyzed and stored for quarterly composites from an offsite laboratory. The analyzed samples include hard to detect nuclides that may be present scaled into the isotopic mixture and the results of the analysis compared with effluent release limits per 10CFR20 table 2 column 2 prior to release. If the water fails the comparison, it is sent back to the RWST for re-processing. Satisfactory results allow for the discharge of the liquid.

The liquid effluent monitor is verified functional and water is discharged at the rate calculated based on dilution flow into the effluent discharge piping (pre-existing). If the liquid effluent monitor alarms, the downstream valve closes to stop the release prior to reaching the discharge point and a notification is sent to the guard-it dialer notifying operations personnel of the event.

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Waste Water Treatment System Drawing Figure 1 All applicable changes have been evaluated in accordance with 10CFR 50.59 by ANSI qualified technical review personnel. Doses to members of the public have been evaluated during system design to ensure that the system continues to maintain doses to the public and workers are as low as reasonably attainable and well within limits.

ZionSolutions LLC ZS-2015-0055: Zion Station Radioactive Effluent Release Report for 2014 Attachment 8 - Station Review and Reason for inoperable monitor surveillances conducted > 30 days.

Station Review Date: 12/3/14 To: Station Review Committee

Subject:

2RIA-PR49 Channel 1,5 Inoperable >30 days per ODCM Table 12.2-3 Surveillance 10, 11 Supporting Documentation: TR-032-2014 After an exhaustive search was performed, it is determined the SPING monitor being used to monitor effluent from Unit 2 vent stack is unable to be repaired due to repair parts no longer available. The SPING unit being in place as 2RIA-PR49 is no longer manufactured by Eberline and no repair parts are supported. The SPING unit that was in use for Unit 1 vent stack parts had already been salvaged and used for repairs in the past. Other stations have been contacted for salvage parts and various parts dealers have been contacted for the parts to repair the SPING unit. None were found. To have an effluent radiation monitor built to the design required, manufacturers ask for an 18 month lead time to build an effluent monitor for Zion Station. TR-032-2014 has determined that installing an AMS-4 such as the one in Unit 1 will meet the requirement for gaseous effluent radiation monitoring, and this system can be installed within 4 weeks; however, Zion will exceed the 30 days prescribed to restore normal effluent monitoring and this station review satisfies the ODCM requirement to determine the course of action to restore effluent monitoring.

Channel I particulate: This change was previously evaluated and will be established by using an AMS-4 similar to the operation of 1RIA-PR49 that is currently in place. This change will be implemented now instead of after all fuel is removed from Spent Fuel Pool.

Channel 5 noble gas: Several alternate methods of re-establishing continuous noble gas monitoring were examined. Each of the three alternate methods required an engineering change, and physical reconfiguration of one form or another to establish a suitable monitoring flowpath.

Two of the methods for noble gas monitoring would require evaluation time that would place the timeline of re-establishing noble gas monitoring past January 31, 2015 or later and thus the method presented here is the only reasonable method of re-establishing continuous noble gas monitoring while fuel is still present.

Technical Review summary of Channel 5 noble gas method: Engineers of Thermo-Scientific were contacted to determine if the AMS-4 particulate monitor could also be used to monitor noble gas concurrently with particulate. The contact personnel responded that it was possible, using correction factors and efficiencies for Kr-85 instead of Sr-90. The alarm setpoint will be extremely low since the detector volume is setup for particulate. However this is feasible since there has been less than minimum detectable particulate effluent. This single setpoint based on noble gas will also satisfy the particulate alarm setpoint. Once all fuel is removed, the setpoint can be changed to reflect only the particulate setpoint.

The Station Review Committee concurred with the proposed corrective actions. Corrective actions were completed on December 29, 2014 and the Unit 2 vent stack effluent radiation monitor was placed back in service.