Attachment 1:
Radioactive Effluent Release Report ZION NUCLEAR POWER STATION 2011 RADIOACTIVE EFFLUENT RELEASE REPORT UNIT 1 & 2 (DOCKET Numbers 50-295 & 50-304)
EXECUTIVE
SUMMARY
A review of 2011 effluent data indicates that the activity released from the station was far below any regulatory limit. There was no noble gas released in 2011. This trend can be attributed to the shutdown of both units since late September 1997.
Airborne Dose to Maximally Exposed Receptor from Unit 1 Dose to Maximally Exposed Receptor from Unit 2 Gamma Air 0 mrad 0 mrad Beta Air 0 mrad 0 mrad Total Body 2.26E-04 mrem 6.00E-5 mrem (Adult)
(Child)
Skin 0 mrem 0 mrem Organ 6.32E-04 mrem 6.00E-05 mrem (Infant Liver)
(Child Liver)
There was NO Aquatic release of radioactivity from Zion Station for 2011.
Aquatic Dose to Maximally Exposed Receptor (Any) from Unit 1 Dose to Maximally Exposed Receptor (Any) from Unit 2 Total Body 0 mrem 1
0 mrem Organ 0 mrem 0 mrem K:\\RP\\EFFLUENT\\1OAER\\AER201 lexec sum
ZION STATION 2011 Unit 1 10CFR20 Compliance Assessment
- 1.
10CFR 20.1301 (a) (1) Compliance Total Effective Dose Equivalent 10 CFR 20.1301 (a) (1) limit
% of the limit
- 2.
Compliance Summary 10CFR20 1st Qtr.
2 nd Qtr.
3r(
DE 1.49E-05 1.51E-05 1.:
9.03E-04 mrem/year 100 mrem/year 0.000903 d Qtr.
50E-05 4 th Qtr 8.58E-04
% of Limit 0.000903 TE K:\\RP\\EFFLUENT\\I 1 AER\\AER_1 CFRCompliance_11.doc
ZION STATION 2011 Unit 2 10CFR20 Compliance Assessment I0CFR 20.1301 (a) (1) Compliance I.
Total Effective Dose Equivalent 10 CFR 20.1301 (a) (1) limit
% of the limit 6.OOE-05 mrem/year 100 mrem/year 0.000060
- 2.
Compliance Summary 10CFR20 1St Qtr.
2 nd Qtr.
3 rd Qtr.
TEDE 1.49E-05 1.51E-05 1.50E-05 4th Qtr 1.50E-05
% of Limit 0.000060 K:\\RP\\EFFLUENT\\1 1AER\\AER_ 11CFRCompliance_11.doc
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 1 (Docket Number 50-295)
Infant Receptor Yearly Limit 10CFR 50:
Appendix I Maximum Qtr. Dose (mrad, mrem)
Total dose (mrad, mrem)
% of Yearly Limit A. Airborne QTR Obj.
1st Qtr.
2nd Qtr.
3 Qtr.
4 Qtr.
Gamma Air 5.0 mrad 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 Beta Air 10.0 mrad 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 otal Body 7.5mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Skin B7.5mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Organ 7.5 mrem 0.00E+00 0.00E+00 0.OOE+00 6.32E-04 Critical Organ NA NA NA LIVER B. Aquatic ITotal Body I,.5 mrem I O.OOE+00 I.OOE+00 10.OOE+00 O.OOE+00 Internal Organ 5.0 mrem I 0.OOE+00 0.OOE+00 1 0.00E I 0.00E+00E 10.0 mrad 0.OOE+00 0
20.0 mrad 0.OOE+00 0
15.0 mrem
.OOE+00 0
15.0 mrem 0.04E+00 0
15.0 mrem 6.32E-04 4.20E-03 LIVER I 3omrem
+000
.E+00 1rem O.OOE+01 O.OOE+O0 Critical Organ I
NA I
NA I
NA I
NA I
K:\\RP\\effluent\\1 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 1 (Docket Number 50-295)
Child Receptor Yearly Limit 10CFR 50 Appendix I Total dose % of (mrad, Yearly mrem)
Limit Maximum Qtr. Dose (mrad, mrem)
QTR Obi.
1st Qtr.
2nd Qtr.
3 Qtr.
A. Airborne 4 Qtr.
Gamma Air 5.0 mrad 0.OOE+00 0.OOE+00
.OOE+00O 0.00E+00 Beta Air 10.0 mrad 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 Total Body 7.5 mrem 1.49E-05 1.51 E-05 1.50E-05 O.OE+00 Skin 7.5 mrem O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Organ 7.5 mrem 1.49E-05 1.51 E-05 1.50E-05 0.00E+00 Critical Organ LIVER LIVER LIVER NA B. Aquatic I-otal Body 11.5 mrem I[ 00E+00 0.00E+000 00E+00I 0.00E+00 Internal Organ 5.0 mrem I o.ooE+00
.OOE+00 0E+00 0.00E+001 10.0 mrad
.OOE+00 0
j 20.0 mrad 0.OOE+00 0
15.0 mrem 4.50E-05 3.OOE-04 15.0 mrem 0.00E+00 0
15.0 mrem 4.50E-05 3.OOE-04 LIVER 3.0 mrem I0.0E+00 0.00 N.A0E+00 0.00 INAI Critical Organ I
NA I
NA I
NA I
NA I
m U
K:\\RP\\effluent\\l 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 1 (Docket Number 50-295)
Teen Receptor Yearly Limit 10CFR 50 Appendix I Maximum Qtr. Dose (mrad, mrem)
Total dose (mrad, mrem)
% of Yearly Limit A. Airborne QTR Obi.
1st Qtr.
2nd Qtr.
3 Qtr.
4 Qtr.
Gamma Air 5.0 mrad 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 Beta Air 10.0 mrad 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 Total Body 7.5 mrem
.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Skin 7.5 mrem
.OO00E+00 0.00E+00f0.00E+00 Organ
[7.5mrem 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Critical Organ I
NA NA NA NA B. Aquatic ITotal Body 11.5 mrern I OOOE+001 00JOE+00E I 00E+00 10.007oo Internal Organ 5.0 mrem I 0.OE+00° OOOE+0OO1 00E I 0.OOE+00!
W ~~0
-001 U-10.0 mrad 0.OOE+00 0
20.0 mrad
.OOE+00 0
15.0 mrem 0.00E+00 0
15.0 mrem j.00E+00 0
15.0 mrem 0.OOE+00 0
NA I 3.0 mrem I 0.OOE+00 1 0.00I 10.0 mremI 0.00E+00
.00n Critical Organ I
A N
INAINAj K:\\RP\\effluent\\l 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 1 (Docket Number 50-295)
Adult Receptor Yearly Limit 10CFR 50 Appendix I Total dose (mrad, mrem)
% of Yearly Limit Maximum Qtr. Dose (mrad, mrem)
A. Airborne QTR Obi. 1st Qtr.
2nd Qtr.
3 Qtr.
4 Qtr.
Gamma Air 5.0 mrad 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Beta Air 10.0 mrad 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Total Body 7.5 mrem 0.00E+00 0.OOE+00 0.00E+00 2.26E-04 Skin 7.5 mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Organ 7.5 mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Critical Organ NA NA NA TBODY B. Aquatic ITotal Body 11.5 mrem I 0ooE+00 oo00E+00I0O0E+00!000E+00 1 Internal Organ 5.0 mrem I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 10.00E+00]
10.0 mrad 0.OOE+00 0
20.0 mrad 0.OOE+00 0
15.0 mrem 2.26E-04 1.50E-03
-I 15.0 mrem 0.OOE+00 0
15.0 mrem 0.OOE+00 0
I TBODY I
mrem 0.00E+00 0
mem 0.00E+00 0
NA Critical Organ I
NA I
NA I
NA I
NA I
K:\\RP\\effluent\\l 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 2 (Docket Number 50-304)
Infant Receptor Yearly Limit 10CFR 50 Appendix I Total dose % of (mrad, Yearly mrem)
Limit Maximum Qtr. Dose (mrad, mrem)
OTR Ohi_
1stQtr.
2rid Otr 3 (tr.
A. Airborne 4 Mtr.
Gamma Air 5.0 mrad 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Beta Air 10.0 mrad 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 Total Body 7.5 mrem 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Skin 7.5mrem 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 Organ 7.5mrem 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 Critical Organ NA NA NA NA B. Aquatic ITotal Body 11.5 mrem I 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Internal Organ 5.0 mrem I 0.OOE+00 I
.OOE+0O 0.OOE+00 0.OOE+00 10.0 mrad 0.OOE+00 0
20.0 mrad 0.00E+00 0
15.0 mrem 0.00E+00 0
15.0 mrem 0.OOE+00 0
15.0 mrem 0.OOE+00 0
0.00OE+00I I3.0mrem I0.0E+0010.00E+00 10.0 mrem I
+0
.00E+00I NA Critical Organ I
NA I
NA I
NA I
NA I
m -
m U
K:\\RP\\effluent\\1 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 2 (Docket Number 50-304)
Child Receptor Yearly Limit 10CFR 50 Appendix I Total dose % of (mrad, Yearly mrem)
Limit Maximum Qtr. Dose (mrad, mrem)
A. Airborne QTR Obi.
1st Qtr.
2nd Qtr.
3 Qtr.
4 Qtr.
Gamma Air 5.0 mrad 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 Total Body 7.5 mrem 1.49E-05 1.51E-05 1.50E-05 1.50E-05 Skin 7.5 mrem O.0OE+00 0.OOE+00 0.OOE+00 0.OOE+00 Organ 7.5 mrem 1.49E-05 1.51 E-05 1.50E-05 1.50E-05 Critical Organ LIVER LIVER LIVER LIVER B. Aquatic Irotal Body 11.5 mrem I 0.00E+00 O.OOE+001 0.00E+00 I.O00E+00I Internal Organ 5.0 mrem I 0.OOE+00 1 0.OOE+00 1 0.OOE+00 1 0.OOE+001 10.0 mrad
.O00E+00 0
20.0 mrad 0.OOE+00 0
15.0 mrem 6.OJE-05 4.00E-04 15.0 mrem 0.00E+00 0
15.0 mrem 6.OOE-05 4.OOE-04 LIVER I 3.o mrem 10.00E+001 0.00 1 L~em jO.OOE+00I 1 10.0mrem M0"0E+001 0.00 Critical Organ I
NA I
NA I
NA I
NA I
K:\\RP\\effluent\\l 1 AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 2 (Docket Number 50-304)
Teen Receptor Yearly Limit Total dose 10CFR 50 (mrad, Appendix I mrem)
% of Yearly Limit Maximum Qtr. Dose (mrad, mrem)
QTR Obi.
1st Qtr.
2nd Qtr.
3 Qtr.
A. Airborne 4 Qtr.
Gamma Air 5.0 mrad
.0E+00 0.00E+00 0.OOE+00 0OOE+00 Beta Air 10.0 mrad O.OOE+00 0.00E+00 0.00E+00 0.00 E+00 Total Body 7.5 mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Skin 7.5 mrem O.OE+00 0.OOE+00 0.OOE+00 0.00E+00 jOrgan 7.5 mrem 0.OE+00 0.OOE+00 0.OOE+00 0.00E+00 Critical Organ NA NA NA NA B. Aquatic ITotal Body 11.5 mrem I O0OOE+00 O.OOE+00I OOOE+00 0.00E+001 Internal Organ 5.0 mrem I0 OOE+00 1 O.OE+00 10 OOE+0010 00E+001 10.0 mrad 0.OOE+00 0
20.0 mrad 0.OOE+00 0
15.0 mrem 0.OOE+00 0
15.0 mrem 0.OOE+00I 0
15.0 mrem 0.OOE+00 0
NA I 3.0 mrem 0.'00E+00 00 10.0 mrem 0.OOE+00 0
Critical Organ I NAINAINA I
NAI K:\\RP\\effluent\\1 1AER\\AER receptors 11.xls
Zion Nuclear Power Station Annual Radioactive Release Report for 2011 Unit 2 (Docket Number 50-304)
Adult Receptor Yearly Limit 10CFR 50 Appendix I Total dose % of (mrad, Yearly mrem)
Limit Maximum Qtr. Dose (mrad, mrem)
A. Airborne QTR Obi.
1st Qtr.
2nd Qtr.
3 Qtr.
4 Qtr.
Gamma Air 5.0 mrad 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 Beta Air 10.0mrad 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Total Body 7.5 mrem 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Skin 7.5 mrem 0.OOE+00 0.00E+00 O.OOE+00 0.OOE+00 Organ 7.5 mrem 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 Critical Organ NA NA NA NA B. Aquatic Total Body 11.5 mrem 0.00E+00I 0.0E+00 0.00E+00 0.OOE+00 Internal Organ 5.0 mrem I O.OE+00I O.OE+00 I0.OOE+00 0.OOE+00 1 10.0 mrad O.OOE+00 0
20.0 mrad 0.OOE+00 0
15.0 mrem 00E+00 0
15.0 mrem O.OOE+00 0
15.0 mrem O.OOE+00 0
NA 3.0 mrem 0.00E+00 0
10.0 mrem 0.00E+001N Critical Organ I
NA I
NA I
NA I
NA I
K:\\RP\\effluent\\1 1AER\\AER receptors 11.xls
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To: 2 Liquid Receptor PERIOD DOSE BY ORGAN AND AGE GROUP (mrem)
QUARTER 1 Agegrp Bone Liver Thyroid Kidney Lung GI-LLI Skin TB SITE DOSE LIMIT ANALYSIS QUARTER 1 Age Dose Limit Quartr - Limit Group Organ (mrem)
(mrem)
Max % of Limit
- 0. 00E+00
- 0. 00E+00 Qtr 1 Qtr 1
- Admin. Any Organ
- Admin. Total Body
- 0. 00E+00
- 0. OOE+00
- 1. 50E+01
- 1. 13E+00 ADULT TBODY Qtr 1 T.Spc. Any Organ Critical Pathway:
Major Contributors
(
0% or greater to total)
Nuclide Percentage Qtr 1 T.Spc. Total Body ADULT TBODY Critical Pathway: Potable Water (PWtr)
Major Contributors
(
0% or greater to total)
Nuclide Percentage 0.OOE+00 3.75E+00 0.00E+00 0.00E+00 1.50E+00 0.00E+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To:
2 Liquid Receptor PERIOD DOSE BY ORGAN AND AGE GROUP (mrem)
QUARTER 2 Agegrp Bone Liver Thyroid Kidney Lung GI-LLI Skin TB SITE DOSE LIMIT ANALYSIS QUARTER 2 Age Dose Limit Max % of Quartr - Limit Group Organ (mrem)
(mrem)
Limit Qtr 2
- Admin. Any Organ 0.OOE+00 5.00E+00 0.OOE+00 Qtr 2
- Admin. Total Body ADULT TBODY 0.OOE+00 1.13E+00 0.OOE+00 Qtr 2
- T.Spc. Any Organ Critical Pathway:
Major Contributors
(
0% or greater to total)
Nuclide Percentage Qtr 2
- T.Spc. Total Body ADULT TBODY Critical Pathway: Potable Water (PWtr)
Major Contributors
(
0% or greater to total)
Nuclide Percentage 0.00E+00 3.75E+00 0.00E+00 0.OOE+00 1.50E+00 0.OOE+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID DOSE
SUMMARY
Report for: 2011 Unit Range -
From: 1 To: 2 Liquid Receptor PERIOD DOSE BY ORGAN AND AGE GROUP (mrem)
QUARTER 3 Agegrp Bone Liver Thyroid Kidney Lung GI-LLI Skin TB SITE DOSE LIMIT ANALYSIS QUARTER 3 Age Dose Limit Quartr - Limit Group Organ (mrem)
(mrem)
Max % of Limit Qtr 3 Admin. Any Organ Qtr 3 Admin. Total Body
- 0. OOE+00
- 0. OOE+00
- 5. OOE+00
- 1. 13E+00
- 0. OOE+00
- 0. OOE+00 ADULT TBODY Qtr 3
- T.Spc.
Any Organ Critical Pathway:
Major Contributors
(
0% or greater to total)
Nuclide Percentage Qtr 3 T.Spc. Total Body ADULT TBODY Critical Pathway: Potable Water (PWtr)
Major Contributors
(
0% or greater to total)
Nuclide Percentage 0.OOE+00 3.75E+00 0.OOE+00 0.OOE+00 1.50E+00 0.OOE+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To: 2 Liquid Receptor PERIOD DOSE BY ORGAN AND AGE GROUP (mrem)
QUARTER 4 Agegrp Bone Liver Thyroid Kidney Lung GI-LLI Skin TB SITE DOSE LIMIT ANALYSIS QUARTER 4 Age Dose Limit Max % of Quartr - Limit Group Organ (mrem)
(mrem)
Limit Qtr 4 Admin. Any Organ 0.OOE+00 5.OOE+00 0.0OE+00 Qtr 4 Admin. Total Body ADULT TBODY 0.OOE+00 1.13E+00 0.OOE+00 Qtr 4
- T.Spc. Any Organ Critical Pathway:
Major Contributors
(
0% or greater to total)
Nuclide Percentage Qtr 4
- T.Spc. Total Body ADULT TBODY Critical Pathway: Potable Water (PWtr)
Major Contributors
(
0% or greater to total)
Nuclide Percentage 0.00E+00 3.75E+00 0.OOE+00 0.OOE+00 1.50E+00 0.OOE+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT LIQUID DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To: 2 Liquid Receptor PERIOD DOSE BY ORGAN AND AGE GROUP (mrem)
ANNUAL 2011----------
Agegrp Bone Liver Thyroid Kidney Lung GI-LLI Skin TB SITE DOSE LIMIT ANALYSIS ANNUAL 2011 Age Dose Limit Annual - Limit Group Organ (mrem)
(mrem)
Max % of Limit
- 0. OOE+00
- 0. 00E+00 2011 Admin.
Any Organ 2011 Admin. Total Body
- 0. OOE+00
- 0. OOE+00 5.OOE+00
- 2. 25E+00 ADULT TBODY 2011
- T.Spc. Any Organ Critical Pathway:
Major Contributors
(
0% or greater to total)
Nuclide Percentage 2011 T.Spc. Total Body ADULT TBODY Critical Pathway: Potable Water (PWtr)
Major Contributors
(
0% or greater to total)
Nuclide Percentage 0.OOE+00 7.50E+00 0.OOE+00 0.OOE+00 3.OOE+00 0.OOE+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFRI90 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 I&P DOSE LIMIT ANALYSIS QUARTER 1 Age Dose Limit Quartr - Limit Group Organ (mrem)
(mrem)
Qtr 1
- Admin. Any Organ CHILD LIVER 2.98E-05 5.63E+C Qtr 1
- Admin. Total Body CHILD TBODY 2.98E-05 5.25E+C Max % of Limit 10 5.30E-04 10 5.68E-04 Qtr 1 T.Spc. Any Organ CHILD LIV Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors
(
0% or greater to total)
Nuclide Percentage ER 2.98 s Point: NA E-05 7.50E+00 3.98E-04 H-3
- 1. OOE+02 Qtr 1 T.Spc. Total Body CHILD TBO Receptor: 5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors
(
0% or greater to total)
Nuclide Percentage H-3 1.00E+02 DY 2.98.
s Point: NA E-05 7.SOE+00 3.98E-04
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 NG DOSE LIMIT ANALYSIS QUARTER 1 Dose Limit Quartr -
Limit (mrad)
(mrad)
Max % of Limit
'0 0.00E+00 0
0.OOE+00 Qtr 1 Admin.
Gamma Qtr 1 Admin. Beta
- 0. 00E+00
- 0. 00E+00 7. 50E+0
- 7. 50E+0 Qtr 1 T.Spc.
Gamma 0.00E+00 7.50E+00 0.OOE+00 Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Point: NA Nuclide Percentage Qtr 1 T.Spc. Beta 0.00E+00 7.50E+00 0.00E+00 Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Point: NA Nuclide Percentage
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To: 2 I&P DOSE LIMIT ANALYSIS QUARTER 2 Age Dose Limit Max % of Quartr - Limit Group Organ (mrem)
(mrem)
Limit Qtr 2
- Admin. Any Organ CHILD LIVER 3.01E-05 5.63E+00 5.36E-04 Qtr 2
- Admin. Total Body CHILD TBODY 3.01E-05 5.25E+00 5.74E-04 Qtr 2
- T.Spc. Any Organ CHILD LIV Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors (
0% or greater to total)
Nuclide Percentage H-3 1.00E+02 Qtr 2
- T.Spc. Total Body CHILD TBC Receptor: 5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors
(
0% or greater to total)
Nuclide Percentage H-3 1.00E+02
'ER 3.01E-05 7.50E+00 4.02E-04 s Point: NA DY 3.01E-05 7.50E+00 4.02E-04 s Point: NA
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 NG DOSE LIMIT ANALYSIS QUARTER 2 Dose Limit Max % of Quartr - Limit (mrad)
(mrad)
Limit Qtr 2
- Admin.
Gamma O.OOE+00 7.50E+00 0.00E+00 Qtr 2
- Admin.
Beta 0.OOE+00 7.50E+00 0.OOE+00 Qtr 2 Receptor:
Distance:
Nuclide T.Spc. Gamma 0.00]
5 Composite Crit. Receptor -
IP 0.00 (meters)
Compass Point: NA Percentage E+00 7.50E+00 0.OOE+00 Qtr 2
- T.Spc. Beta 0.00E+00 7.50E+00 0.OOE+00 Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Nuclide Percentage
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range From:
1 To: 2 I&P DOSE LIMIT ANALYSIS
=-------
-QUARTER 3
Age Dose Limit Max % of Quartr - Limit Group Organ (mrem)
(mrem)
Limit Qtr 3 Admin. Any Organ CHILD LIVER 3.00E-05 5.63E+00 5.33E-04 Qtr 3
- Admin. Total Body CHILD TBODY 3.00E-05 5.25E+00 5.71E-04 Qtr 3 T.Spc. Any Organ CHILD LIV Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors
(
0% or greater to total)
Nuclide Percentage ER 3.OOE-05 7.50E+00 4.OOE-04 s Point: NA H-3
- 1. 00E+02 Qtr 3 T.Spc. Total Body CHILD TBO Receptor: 5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compas Critical Pathway: Vegetation (VEG)
Major Contributors
(
0% or greater to total)
Nuclide Percentage
- 1. --------
DY 3.00 s Point: NA E-05 7.50E+00 4.OOE-04 H-3 1.00OE+02
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 NG DOSE LIMIT ANALYSIS QUARTER 3
Dose Limit Quartr - Limit (mrad)
(mrad)
Max % of Limit 0
0.00E+00 0
0.00E+00 Qtr 3
- Admin.
Gamma Qtr 3
- Admin.
Beta Qtr 3 T.Spc.
Gamma Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Po Nuclide Percentage
- 0. 00E+00
- 0. OOE+00
- 7. 50E+0 7.50E+0 0.OOE+00 7.50E+00 0.OOE+00 int: NA Qtr 3 T.Spc. Beta Receptor:
5 Composite Crit. Receptor Distance:
0.00 (meters)
Nuclide Percentage 0.OOE+00 7.50E+00 0.00E+00 IP Compass Point: NA
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To:
2 I&P DOSE LIMIT ANALYSIS QUARTER 4
Age Dose Limit Quartr Limit Group Organ (mrem)
(mrem)
Qtr 4
- Admin. Any Organ INFANT LIVER 6.32E-04 5.63E+00 Qtr 4
- Admin. Total Body ADULT TBODY 2.26E-04 5.25E+00 Max % of Limit 1.12E-02
- 4. 31E-03 Qtr 4
- T.Spc.
Any Organ INFANT LIVER 6.32]
Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Critical Pathway: Grs/Goat/Milk (GMILK)
Major Contributors
(
0% or greater to total)
Nuclide Percentage E-04 7.50E+00 8.42E-03 H-3 CO-60 CS-137 3.69E+00
- 1. 71E+01 7.92E+01 Qtr 4
- T.Spc. Total Body ADULT TBODY 2.26E-04 7.50E+00 3.01E-03 Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Critical Pathway: Ground Plane Deposition (GPD)
Major Contributors
(
0% or greater to total)
Nuclide Percentage H-3 8.05E+00 CO-60 4.86E+01 CS-137 4.33E+01
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 NG DOSE LIMIT ANALYSIS Dose Quartr - Limit (mrad)
QUARTER 4 Limit Max % of (mrad)
Limit Qtr 4
- Admin.
Gamma Qtr 4
- Admin.
Beta
- 0. 00E+00
- 0. 00E+00 7.50E+00 7.50E+00
- 0. 00E+00
- 0. OOE+00 Qtr 4 T.Spc.
Gamma Receptor:
5 Composite Crit. Receptor Distance:
0.00 (meters)
Nuclide Percentage 0.OOE+00 7.50E+00 0.OOE+00 IP Compass Point: NA Qtr 4 T.Spc. Beta 0.OOE+00 7.50E+00 0.OOE+00 Receptor: 5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Point: NA Nuclide Percentage
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 I&P DOSE LIMIT ANALYSIS Age Dose Annual Limit Group Organ (mrem) 2011 Admin.
Any Organ 2011 Admin.
Total Body ANNUAL 2011 Limit (mrem)
)4 1.13E+01
)4 1.05E+01 Max % of Limit
- 6. 24E-03 2.95E-03 INFANT CHILD LIVER TBODY
- 7. 02E-0
- 3. 10E-0 2011 T.Spc. Any Organ INFANT LIVER 7.02E-04 1.50E+01 4.68E-03 Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Critical Pathway: Grs/Goat/Milk (GMILK)
Major Contributors
(
0% or greater to total)
Nuclide Percentage H-3 CO-60 CS-137 1.33E+01
- 1. 54E+01 7.13E+01 2011 T.Spc. Total Body CHILD TBODY 3.10E-04 1.50E+01 2.07E-03 Receptor: 5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Critical Pathway: Ground Plane Deposition (GPD)
Major Contributors
(
0% or greater to total)
Nuclide Percentage H-3 3.87E+01 CO-60 3.67E+01 CS-137 2.46E+01
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT GASEOUS DOSE
SUMMARY
Report for: 2011 Unit Range -
From:
1 To: 2 NG DOSE LIMIT ANALYSIS Dose Annual Limit (mrad)
ANNUAL 2011 Limit (mrad)
Max % of Limit
- 0. 00E+00
- 0. 00E+00 2011 Admin.
Gamma 2011 Admin.
Beta
- 0. 00E+00
- 0. 00E+00
- 1. 50E+01
- 1. 50E+01 2011 T.Spc.
Gamma 0.00E+00 1.50E+01 0.OOE+00 Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Point: NA Nuclide Percentage 2011 Receptor:
Distance:
Nuclide T.Spc. Beta 0.00 5
Composite Crit. Receptor IP 0.00 (meters)
Compass Point: NA Percentage E+00 1.50E+01 0.00E+00
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT Report for: 2011 Unit Range -
From:
1 To: 2 MAXIMUM DOSE ANALYSIS ANNUAL 2011 Age Dose Dose Type Group Organ (mrem)
Any Organ INFANT LIVER 7.02E-04 Liquid Receptor:
NA Gaseous Receptor:
5 Composite Crit. Receptor -
IP Distance:
0.00 (meters)
Compass Point: NA Liquid Dose:
Critical Pathway:
Major Contributors Nuclide Gaseous Dose:
Critical Pathway:
Major Contributors Nuclide H-3 CO-60 CS-137 0.OOE+00
% of Total: 0.OOE+00 Potable Water (PWtr) 0% or greater to total)
Percentage 7.02E-04
% of Total: 9.99E+01 Grs/Goat/Milk (GMILK) 0% or greater to total)
Percentage 1.33E+01 1.54E+01 7.13E+01 MAXIMUM DOSE ANALYSIS ANNUAL 2011 Age Dose Dose Type Group Organ (mrem)
Total Body CHILD TBODY 3.10E-04 Liquid Receptor:
NA Gaseous Receptor:
5 Composite Crit. Receptor IP Distance:
0.00 (meters)
Compass Point: NA Liquid Dose:
Critical Pathway:
Major Contributors Nuclide Gaseous Dose:
Critical Pathway:
Major Contributors Nuclide H-3 CO-60 0.00E+00
% of Total: 0.OOE+00 Potable Water (PWtr) 0% or greater to total)
Percentage 3.10E-04
% of Total: 1.OOE+02 Ground Plane Deposition (GPD) 0% or greater to total)
Percentage 3.87E+01 3.67E+01
RETDAS v3.6.3
<ZIO>
VSSI 40CFR190 URANIUM FUEL CYCLE DOSE REPORT Nuclide Percentage CS-137 2.46E+01
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Extremely Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 5
5 8
10 0
0 1
0 0
- 1.
0 0
3 0
0 0
2 30 10 5
15
.0 1
0 2..
0 5
4 9
11 1
3 0
0 1
4 0
0 0
.0 0
0 5
3 1
9 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 3
36 19 13 25 0
1 1
2 5
9 5
18 14 1
3 0
Total 0
34 98 23 0
0 155 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Moderately Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total 1-3 4-7 8-12 13-18 19-24 24 Total 0
6 0
10 0
0 0
0 0
5 2
0 0
1 1
7 1
2 6
0 0
0 0
0 0
0 0
0 4
2 0
0 0
4 4
7 3
0 0
2 2
0 2
0 0
7 1
0 0
0 0
0 1
0 0
0 7
0 11 9
5 0
0 0
0 0
21 44 0
73 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
1 all stability classes:
4
Zion Nuclear Station Period of Record: January - March 2011 Stability Class - Slightly Unstable Winds Measured at 250Ft-33Ft Delta-T (F) 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 8
9 2
1 1
1 2
5 3
1 8
7 5
12 8
4 0
0 0
1 3
1 0
0 4
0 1
4 4
1 0
4 0
0 0
0 5
4 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 8
14 13 12 3
1 5
12 4
3 16 16 14 15 13 5
0 Total 1
44 77 23 9
0 154 Hours of calm in this Hours of missing wind stability class:
0 measurements in this stability class:
6 Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Neutral 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW NNW Variable 23 24 21 9
1 10 6
6 13 25 35 38 37 50 51 22 0
32 42 27 21 13 10 10 21 25 18 39 34 34 53 67 53 0
499 27 19 15 25 21 5
2 25 3
10 32 21 26 2
3 11 0
247 9
4 7
25 3
0 0
8 0
0 0
0 0
0 0
1 0
93 100 82 83 41 27 20 60 44 57 109 97 102 109 123 90 0
Total 50 371 57 13 1237 Hours of calm in this stability class:
0 Hours of missing wind measurements in this s tability class:
23 11 stability classes:
Hours of missing stability measurements in a
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Slightly Stable Winds Measured at Wind Spee Wind Direction 1-3 4-7 8-12 250Ft-33Ft Delta-T (F) 35 Feet d (in mph) 13-18 19-24
> 24 Total N
NNE 3
12 7
17 0
3 0
2 NE 1
3 7
ENE 0
0 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 9
6 4
5 0
15 0
27 E
ESE 1
2 1
2 2
2 5
2 1
7 5
SE 0
13 SSE 0
9 S
WNW NW NNW Variable Total 4
8 11 4
15 8
14 9
7 7
26 18 7
26 18 8
39 23 0
0 3
6 1
0 0
0 0
11 0
23 0
28 0
32 0
57 0
52 0
70 0
39 0
10 9
29 9
0 1
0 1
0 0
106 0
0 76 206 0
399 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: January - March 2011 Stability Class -
Moderately Stable Winds Measured at 250Ft-33Ft Delta-T (F) 35 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
1 0
2 0
0 1
7 6
3 6
11 14 12 6
0 Total 33 39 8
0 0
0 80 Hours of calm in this stability class:
0 Hours of missing wind measurements in this si Hours of missing stability measurements in al tability class:
0 11 stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Extremely Stable Winds Measured at Wind Spee(
Wind Direction 1-3 4-7 8-12 N
0 0
0 NNE 0
0 0
NE 0
0 0
ENE 0
0 0
E 0
0 0
250Ft-33Ft Delta-T (F) 35 Feet d (in mph) 13-18 19-24
> 24 Total ESE SE 0
0 2
1 SSE S
2 4
0 0
2 7
0 0
0 1
2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
1 0
0 0
0 0
0 0
5 9
W WNW NW NNW Variable 3
0 0
0 2
5 5
0 0
0 Total 14 12 2
0 0
U 28 Hours of
.Hours of Hours of calm in missing missing this stability class:
0 wind measurements in this stabi stability measurements in all s
lity class:
0 tability classes:
4
Zion Nuclear Station Period of Record: January -
Stability Class - Extremely Unstable Winds Measured at 250 March 2011 250Ft-33Ft Delta-T (F)
Feet Wind Direction N
Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total NNE NE ENE E
SSW 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 2
2 0
0 4
0 20 0
12 2
8 3
17 0
0 0
0 0
6 0
1 2
0 9
9 2
3 0
0 0
0 1
4 2
4 6
3 0
0 0
2 0
0 0
1 0
0 3
4 2
2 0
0 0
0 0
29 0
23 0
12 0
23 0
0 0
0 0
6 1
1 2
4 SW WSW W
WNW NW NNW Variable 1
0 10 0
0 0
0 0
0 0
3 8
0 4
7 16 0
14 2
0 0
0 0
4 2
0 Total 0
6 83 45 14 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class 7
155 0
Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Moderately Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
0 0
0 0
0 0
0 0
0 0
4-7 8-12 13-18 19-24
> 24 Total 0
3 0
10 0
0 0
0 0
0 0
0 0
7 3
1 1
0 5
4 2
5 WSW 0
W 0
WNW NW NNW Variable Total 0
0 0
0 0
1 0
0 0
0 0
2 3
2 1
0 0
4 3
7 1
1 0
1 0
0 3
0 0
5 2
10 2
0 0
0 0
8 9
5 1
0 9
29 27 4
74 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Slightly Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 7
11 12 14 9
2 5
7 7
3 6
24 12 15 14 8
0 Total 1
16 63 42 19 15 156 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
4 all stability classes:
Hours of missing stability measurements in 4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Neutral 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 0
8 11 14 1
14 22 32 0
7 21 26 0
8 17 11 0
5 10 19 1
7 6
8 1
2 9
10 1
5 3
13 0
2 13 24 0
8 23 6
0 6
34 20 0
13 34 27 1
12 17 32 0
9 30 34 0
8 33 64 0
8 20 54 0
0 0
0 19-24 15 8
31 17 7
12 13 11 10 26 23 38 9
17 9
0
> 24 20 15 11 29 11 2
1 8
3 1
5 4
12 3
0 5
0 Total 68 95 73 96 62 31 35 43 53 48 91 101 112 85 122 96 0
Total 5
- 122 303 394 257 130 1211 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stability class:
49 Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class -
Slightly Stable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
1 7
NNE 8
0 10 0
22 0
16 1
16 NE ENE E
ESE SE 0
0 0
0 0
0 0
0 0
0 6
4 2
0 2
2 1
4 0
SSE 9
1 1
10 0
8 17 13 0
10 1
13 0
11 0
11 0
25 2
27 3
43 2
67 0
39 0
52 0
28 WSW 2
W 1
4 13 33 14 WNW NW 0
0 0
0 3
13 14 2
9 35 NNW 2
11 14 9
6 1
0 66 Variable Total 0
0 0
153 0
0 3
53 115 9
399 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: January -
March 2011 Stability Class - Moderately Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 8-12 13-18 1-3 4-7 19-24
> 24 Total 11 3
3 0
0 0
4 8
12 1
4 6
5 4
8 0
Total 6
19 26 26 3
0 80 0
Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: January -
Stability Class - Extremely Stable Winds Measured at 250 March 2011 250Ft-33Ft Delta-T (F)
Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
1 2
0 1
0 0
0 0
0 0
4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
2 2
2 0
1 0
0 3
5 8
2 2
0 0
0 0
0 WSW W
WNW NW NNW Variable Total 0
0 0
0 0
6 0
27 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 1
stability class:
all stability cl 0
asses:
4
Zion Nuclear St'ation Period of Record: April - June 2011 Stability Class - Extremely Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 2
12 28 3
0 45 NNE 0
9 26 0
1 0
36 NE 0
13 3
0 0
0 16 ENE 0
3 7
0 0
0 10 E
0 7
0 2
0 0
9 ESE 0
2 0
0 0
0 2
SE 0
1 0
0 0
0 1
SSE 0
1 2
1 0
0 4
S 0
0 0
0 0
0 0
SSW 0
0 2
6 0
0 8
SW 0
0 8
9 0
0 17 WSW 0
0 8
17 0
0 25 W
0 0
25 17 0
0 42 WNW 0
3 23 2
0 0
28 NW 0
0 7
0 0
0 7
NNW 0
1 0
0 0
0 1
Variable 0
0 0
0 0
0 0
Total 0
42 123 82 4
0 251 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April -
June 2011 Stability Class - Moderately Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 2
10 7
12 0
21 0
19 NNE NE ENE E
WNW NW NNW Variable Total 0
0 0
0 0
0 0
0 0
0 0
0 0I 0
0 4
3 1
3 2
1 0
5 5
8 6
6 0
0 0
2 19 41 22 0
84 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April June Stability Class - Slightly Unstable Winds Measured at 25' 35 Feet 2011 OFt-33Ft Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 4
10 3
3 5
2 2
2 0
0 0
1 1
1 1
1 0
11 15 1
1 0
0 0
4 0
5 3
5 10 7
1 0
0 11 1
0 1
0 0
0 0
0 3
3 1
1 0
0 0
0 28 27 4
5 5
2 2
6 0
9 6
7 12 8
2 1
0 Total 1
36 63 21 3
0 124 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April -
June 2011 Stability Class Wind Direction 1
Neutral
- 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
-3 4-7 8-12 13-18 19-24
> 24 Total N
2 29 100 52 54 NNE NE ENE E
SSW 3
55 28 13 0
6 7
18 3
19 5
12 2
11 2
18 9
4 9
12 6
3 1
6 0
19 27 8
7 5
5 0
9 9
2 1
0 1
2 2
6 4
1 0
1 2
239 0
99 0
44 0
49 0
29 0
21 0
32 0
52 0
11 0
29 0
52 0
37 0
60 0
58 0
25 0
22 2
15 9
32 SW WSW W
WNW NW NNW Variable Total 2
11 21 0
13 26 21 2
22 32 4
12 1
14 7
5 0
325 2
2 2
0 153 0
1 0
0 0
0 0
71 0
0 0
0 38 270 2
859 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class
- Slightly Stable Winds Measured at 250Ft-33Ft Delta-T (F) 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 18 9
13 6
7 7
5 4
7 3
5 3
4 7
7 8
0 48 32 11 7
11 7
20 26 32 9
14 18 26 8
2 15 0
8-12 13-18 19-24
> 24 Total 18 0
0 0
84 9
0 0
0 50 3
0 0
0 27 6
3 1
0 23 3
1 0
0 22 3
0 0
0 17 9
0 0
0 34 28 2
0 0
60 15 3
0 0
57 6
1 0
0 19 7
0 0
0 26 4
0 0
0 25 5
0 0
0 35 0
0 0
0 15 0
0 0
0 9
0 0
0 0
23 0
0 0
0 0
Total 113 286 116 10 1
0 526 0
Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April - June Stability Class -
Moderately Stable 25 Winds Measured at 35 Feet 2011 0Ft-33Ft Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE 6
8 6
5 0
1 1
E 5
4 2
5 6
8 1
0 0
3 4
0 0
0 0
0 1
0 0
0 0
0 0
0 0
0 0
11 0
15 0
11 3
ESE SE 1
2 3
0 10 0
11 0
14 0
31 0
33 SSE S
19 5
21 5
10 3
W 5
2 1
1 4
3 2
0 0
5 1
1 0
0 0
0 0
0 0
12 WNW NW 0
8 4
3 4
0 0
0 0
0 0
4 9
7 5
4 0
NNW Variable 0
Total 71 76 35 6
0 0
188 Hours of Hours of Hours of calm in missing missing this stability class:
2 wind measurements in this stability class:
0 stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April
- June 2011 Stability Class - Extremely Stable Winds Measured at 250Ft-33Ft Delta-T (F) 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
ESE 2
0 1
3 2
1 1
2 0
1 2
3 0
0 2
1 4
2 0
0 0
1 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 3
2 3
6 8
7 SE 1
3 SSE S
7 12 4
19 W
WNW NW NNW Variable Total 6
1 11 10 8
2 2
0 3
1 1
5 4
0 0
0 4
0 0
0 0
0 0
0 0
1 0
0 0
0 0
0 0
0 0
3 0
0 9
2 0
0 0
0 0
0 0
23 0
27 0
12 0
15 0
12 0
0 0
2 2
0 57 50 26 0
136 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 5
stability class:
0 all stability classes:
9
Zion Nuclear Station Period of Record: April Stability Class -
Extremely Unstable Winds Measured at 250 June 2011 250Ft-33Ft Delta-T (F)
Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 N
NNE NE ENE E
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 1
6
> 24 Total 4
13 7
58 0
17 0
19 0
19 19 13 3
11 6
4 1
0 0
0 0
0 0
0 0
0 0
0 9
1 2
1 1
0 0
0 0
1 3
4 1
0 1
0 0
0 6
0 0
0 0
2 1
5 7
0 0
0 0
0 0
7 3
2 3
1 5
5 11 17 12 W
0 13 6
22 8
38 2
33 0
16 WNW NW NNW Variable Total 3
25 2
13 3
1 0
0 1
0 0
0 0
0 1
0 0
15 52 95 62 27 251 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class -
Moderately Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 5
10 1
0 0
1 0
0 0
1 1
2 3
4 3
0 0
19-24 5
1 1
1 0
0 0
0 0
3 3
4 4
0 0
0 0
> 24 Total 14 22 8
2 3
2 0
3 0
4 4
6 9
4 3
0 0
Total 1
11 15 31 22 4
84 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class -
Slightly Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 0
1 5
4 NNE NE ENE E
ESE 0
10 13 5
19 3
27 0
10 0
0 0
0 SE 0
SSE S
SSW 0
0 0
0 0
SW 3
0 0
0 0
0 0
0 0
1 0
0 7
3 3
3 1
4 0
0 1
1 0
0 0
0 0
0 0
5 1
6 4
7 1
10 WSW 0
5 W
WNW NW NNW 0
0 0
0 0
0 0
1 0
0 0
7 8
3 0
0 4
0 0
0 0
0 0
0 0
0 ii 9
4 0
0 Variable Total 8
39 49 18 10 124 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class - Neutral
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 1
9 13 11 12 7
2 6
2 1
1 0
0 0
2 8
0 19 46 13 12 3
10 8
14 6
2 7
1 6
17 9
8 0
41 55 16 12 2
3 11 12 5
4 29 13 25 38 10 6
0 33 14 3
10 5
11 10 8
6 9
18 6
24 9
6 1
0 173 77 19 3
15 1
6 6
0 0
1 2
3 4
3 0
0 0
140 171 144 50 60 23 38 37 41 20 17 58 24 59 67 27 23 0
859 8
75 181 282 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class - Slightly Stable 25OFt-33Ft Winds Measured at 250 Feet Delta-T (F)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 5
5 13 6
8 10 9
7 2
4 0
0 0
2 1
1 0
13 24 21 8
8 10 17 17 9
3 5
4 4
6 8
6 0
15 27 9
9 5
4 11 20 20 13 13 13 24 18 5
2 0
0 0
2 3
4 4
8 14 9
4 2
2 0
1 0
0 0
35 57 46 28 30 31 53 61 42 25 20 19 28 27 14 9
1 Total 11 73 163 208 53 18 526 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
9
Zion Nuclear Station Period of Record: April - June 2011 Stability Class - Moderately Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 1
1 1
3 0
8 14 8
5 0
1 5
1 2
0 5
14 8
7 9
18 18 35 33 13 10 0
2 7
4 7
0 Total 1
43 56 50 28 12 190 Hours of calm in this stability class:
0 Hours of missing Hours of missing wind measurements in this stabili ty class:
0 stability measurements in all sta*bi]lity classes:
9
Zion Nuclear Station Period of Record: April Stability Class -
Extremely Stable Winds Measured at 250 June 2011 250Ft-33Ft Delta-T (F)
Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
1-3 4-7 8-12 13-18 19-24
0 1
1 0
0 0
0 0
0 0
1 0
0 1
2 0
0 0
2 2
1 2
1 0
1 0
0 0
0 0
0 1
9 1
3 3
10 2
10 S
8 0
0 2
0 0
1 1
2 7
3 0
0 0
0 0
0 0
6 10 1
8 0
0 1
0 3
1 25 2
29 0
19 0
11 4
5 1
4 4
WNW NW NNW Variable Total 2
2 3
0 0
2 12 5
2 2
1 0
2 0
4 0
0 0
1 3
0 0
0 0
0 0
0 6
2 1
1 1
0 3
0 3
9 0
7 23 43 38 16 14 141 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in stability class:
0 all stability classes:
9
Zion Nuclear Station Period of Record: July - September 2011 Stability Class -
Extremely Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 3
24 18 NNE NE ENE E
27 40 0
33 13 1
27 1
0 31 1
0 28 7
0 20 2
0 7
14 0
45 0
72 0
46 0
29 0
32 0
35 0
22 0
'23 0
1 1
0 2
8 4
4 8
0 0
6 7
0 16 24 W
0 9
10 WNW NW NNW Variable Total 0
0 0
0 4
7 4
0 9
9 2
0 172 2
1 0
0 1
0 32 0
0 0
0 0
0 0
0 19 0
42 0
20 0
13 0
16 0
0 7
0 4
226 0
434 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabi Hours of missing stability measurements in all s lity class:
0 tability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class - Moderately Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
4 NNE NE ENE E
0 1
0 0
0 0
0 0
0 0
0 0
1 0
0 4
2 4
3 2
4 0
0 12 0
0 0
0 0
0 6
6 5
2 1
2 5
1 1
0 2
2 0
0 6
2 0
2 7
4 1
2 3
0 1
2 0
14 0
0 0
4 2
3 W
WNW NW NNW variable Total 2
0 0
0 0
0 4
1 0
0 0
0 0
0 0
1 0
0 0
0 0
0 11 6
2 7
4 0
3 35 37 11 0
87 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: July -
Stability Class - Slightly Unstable Winds Measured at Wind Speed Wind September 2011 250Ft-33Ft Delta-T (F) 35 Feet (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 14 10 9
4 2
5 6
23 5
6 5
10 3
6 9
10 0
Total 6
69 40 12 0
0 127 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: July - Septemb Stability Class - Neutral 25 Winds Measured at 35 Feet Wind Speed (in mph er 2011 OFt-33Ft Delta-T (F)
)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 15 22 13 6
9 13 29 24 15 15 20 20 21 9
17 21 0
18 10 17 7
13 6
16 34 4
9 25 21 8
4 3
23 0
7 1
0 0
5 2
5 22 2
3 3
0 4
2 5
6 0
67 19-24 0
0 0
0 2
0 0
1 0
0 0
0 0
0 0
0 0
> 24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Total 46 36 33 22 29 27 52 87 22 30 51 42 34 18 28 53 0
Total 53 269 218 3
0 610 Hours of calm in this stability class:
Hours of missing wind measurements in this 0
stability class:
0 Hours of missing stability measurements in all stabi lity classes:
4
Zion Nuclear Station Period of Record: July -
Stability Class - Slightly Stable Winds Measured at Wind Speed Wind September 2011 250Ft-33Ft Delta-T (F) 35 Feet (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 9
7 4
1 5
6 7
7 15 22 8
3 9
6 16 9
0 17 17 8
3 4
11 11 10 25 26 21 27 29 30 27 31 0
5 13 1
0 1
1 4
13 5
7 9
4 0
2 3
3 0
71 31 37 13 4
10 18 23 32 46 55 38 34 38 38 46 43 0
Total 134 297 4
0 0
506 0
Hours'of calm in this stability class:
1 Hours of missing wind measurements in this stability class:
Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: July -
Stability Class - Moderately Stable Winds Measured at September 2011 250Ft-33Ft Delta-T (F) 35 Feet Wind Direction N
Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 4
1 1
NNE NE ENE E
WNW 0
2 2
2 0
2 2
1 0
0 0
0 7
10 22 16 22 10 20 17 0
0 0
0 0
0 2
0 0
0 0
0 0
0 0
0 0
2 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 5
2 2
3 2
2 2
2 0
17 0
38 0
32 0
37 0
26 0
33 0
42 0
21 17 9
16 17 16 26 NW NNW Variable Total 12 0
145 9
0 119 0
0 0
266 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class -
Extremely Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
1 0
2 0
1 7
7 12 37 24 6
2 2
0 1
0 0
0 0
0 0
1 4
2 3
5 21 29 4
0 0
70 1
0 0
1 0
2 0
2 12 9
15 42 45 35 6
2 0
Total 101 1
0 0
0 172 0
Hours of calm in this stability class:
1 Hours of missing wind measurements in this stability class:
Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class -
Extremely Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 1
4 2
8 11 NNE NE ENE E
ESE 4
26 34 13 0
10 29 1
17 11 2
16 8
8 0
9 SE 0
10 26 9
0 1
4 4
3 5
1 3
SSE S
0 0
0 0
0 0
0 0
0 2
2 7
4 14 0
0 0
0 0
1 1
1 0
6 2
3 0
1 0
0 0
8 4
1 26 1
79 0
48 0
29 0
27 0
21 0
40 0
22 2
13 12 1
21 11 W
0 10 0
33 0
35 0
12 0
22 WNW 2
3 4
NW NNW Variable 1
0 11 10 0
0 3
1 0
0 0
6 0
0 0
Total 5
80 186 110 39 2
422 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
all stability cl 12 asses:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class - Moderately Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 0
0 1
0 0
0 0
0 0
0 0
0 0
0 1
0 0
4-7 0
3 2
3 2
8-12 13-18 19-24
> 24 Total 2
3 0
0 2
0 2
3 0
0 0
0 0
0 1
0 0
3 2
0 1
2 2
4 0
0 0
0 2
3 0
1 1
4 3
1 5
0 0
0 0
0 0
1 0
0 0
0 0
0 0
0 0
4 9
1 3
8 7
3 9
6 1
3 0
4 2
0 0
4 3
1 0
0 0
0 0
0 2
6 1
0 10 0
0 0
0 4
7 3
0 0
Total 2
16 25 24 15 1
83 4
Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class - Slightly Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
1 NNE NE ENE E
WNW NW 3
2 1
0 0
1 4
7 2
4 2
0 0
0 0
0 2
1 0
11 0
13 0
0 0
8 2
2 0
0 6
7 0
17 0
10 1
0 0
4 1
2 2
0 3
5 0
0 3
0 0
1 2
0 6
6 0
0 7
0 3
0 10 0
10 NNW Variable Total 0
0 1
0 2
0 0
0 2
24 46 34 16 0
122 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
5 all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class - Neutral 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 8-12 13-18 1-3 4-7 6
3 9
7 4
8 14 16 7
1 2
2 3
3 4
1 0
16 13 7
6 5
7 10 25 14 7
10 14 12 7
7 10 0
10 15 12 5
11 9
20 14 8
4 20 18 20 4
10 18 0
19-24 5
12 9
0 3
3 9
12 2
2 8
12 3
1 0
12 0
> 24 Total 37 48 39 19 28 28 60 70 33 16 41 46 39 19 26 42 0
Total 5
90 170 this stability class:
198 93 35 591 Hours of calm in Hours of missing 0
wind measurements in this stability class:
19 Hours of missing stability measurements in all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class - Slightly Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 1
4 28 10 7
11 18 NNE NE ENE E
12 10 0
1 1
2 8
3 5
5 4
4 7
9 3
1 3
1 6
7 1
8 0
0 0
1 0
6 0
12 11 0
43 0
45 0
26 0
13 0
11 0
15 1
23 0
36 1
48 0
30 0
38 0
22 0
34 0
25 0
37 0
31 S
WNW NW NNW Variable Total 0
15 17 14 1
2 0
0 1
0 0
0 3
10 16 4
0 7
19 8
11 0
11 23 1
0 6
3 0
0 5
1 0
32 2
4 18 0
15 17 4
11 15 0
0 0
182 0
0 10 84 167 2
477 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
30 all stability classes:
4
Zion Nuclear Station Period of Record: July -
September 2011 Stability Class -
Moderately Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
1 1
0 2
0 0
0 3
14 10 8
7 4
7 2
5 8
9 3
1 0
1 0
1 0
0 0
0 0
0 0
5 9
7 0
0 0
0 0
0 1
0 0
0 0
0 2
0 0
28 0
18 0
11 0
0 0
0 0
5 9
3 6
9 S
9 17 4
0 0
0 1
0 W
WNW NW NNW 3
5 1
0 6
2 0
8 9
11 3
10 0
32 0
24 0
18 0
25 0
16 0
11 0
17 0
22 2
3 8
7 6
11 Variable 0
0 0
2 0
6 0
0 Total 8
74 88 78 0
254 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stabili ty class:
12 all stability classes:
4
Zion Nuclear Station Period of Record: July - September 2011 Stability Class -
Extremely Stable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE 0
2 0
7 13 0
E 1
5 0
0 5
2 1
3 6
3 1
1 0
0 1
2 4
SSW 0
2 1
1 0
0 1
1 0
3 0
0 0
0 0
0 0
2 4
9 7
2 1
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
0 23 0
10 8
11 6
2 4
6 SW WSW W
WNW 7
2 2
2 5
8 0
8 4
6 1
8 4
0 0
13 0
23 0
24 0
14 0
11 0
4 NW NNW Variable Total 2
1 0
0 16 0
13 0
0 12 63 67 29 0
171 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in stability class:
1 all stability classes:
4
Zion Nuclear Station Period of Record: October December2011 Stability Class -
Extremely Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
SSW SW 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
3 0
10 0
1 0
0 0
0 0
0 0
0 0
2 7
7 0
6 4
WSW W
WNW NW NNW Variable Total 0
0 0
0 0
0 3
2 3
5 2
0 7
12 8
4 1
0 0
5 0
0 0
0 0
0 0
0 0
0 0
12 0
21 0
12 0
0 0
6 2
0 1
40 35 24 0
100 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class Moderately Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 35 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 8-12 13-18 1-3 4-7 19-24
> 24 Total 2
1 0
2 1
0 5
5 2
9 11 9
10 9
1 1
0 Total 0
14 32 20 2
0 68 0
Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
Hours of missing stability measurements in all stability classes:
27
Zion Nuclear Station Period Stability Class of Record: October
- Slightly Unstable Winds Measured at December2011 250Ft-33Ft Delta-T (F) 35 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 4
7 3
0 0
2 2
0 4
4 1
1 0
0 0
0 0
1 1
4 3
4 0
0 0
0 0
0 0
0 0
0 2
0 0
0 0
0 0
0 2
0 0
0 0
0 0
0 0
0 4
3 6
3 8
4 2
9 5
10 10 0
23 0
30 4
19 5
3 5
5 WNW NW NNW Variable Total 3
3 1
0 7
0 1
0 7
0 3
2 3
0 0
0 8
0 13 0
12 0
0 0
6 2
0 1
39 67 29 0
138 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
27
Zion Nuclear Station Period of Record: October Stability Class - Neutral Winds Measured at Wind Speed Wind
- December2011 250Ft-33Ft Delta-T (F) 35 Feet (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 8
0 0
2 1
3 5
20 14 14 28 42 41 30 48 28 0
34 43 23 12 14 9
1 12 27 88 54 22 34 31 32 47 0
28 40 18 6
12 1
0 17 16 54 24 10 19 11 3
15 0
274 4
10 7
0 0
0 0
3 0
3 1
0 0
0 0
0 0
79 100 48 23 28 15 9
55 58 162 116 82 100 78 91 92 1
Total 57 284 483 28 11 1137 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabi Hours of missing stability measurements in all s
lity class:
0 tability classes:
27
Zion Nuclear Station Period of Record: October Stability Class - Slightly Stable Winds Measured at Wind Speed Wind December2011 250Ft-33Ft Delta-T (F) 35 Feet (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 2
2 1
0 2
2 2
8 12 5
4 8
8 6
7 0
0 2
1 0
0 0
0 6
9 35 48 40 29 39 29 13 4
0 4
1 1
1 0
0 0
8 22 27 11 23 32 18 1
1 0
0 0
0 0
0 0
0 3
0 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 8
4 2
1 2
2 8
28 69 81 55 60 79 53 21 5
0 Total 69 255 150 4
0 0
478 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class -
Moderately Stable 250Ft-33Ft Winds Measured at 35 Feet Wind Speed (in mph)
Wind Delta-T (F)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 3-0 0
0 0
0 2
0 0
0 0
0 2
0 0
0 0
0 0
0 0
0 0
0 2
0 0
0 0
0 0
0 3
0 0
0 1
0 0
0 0
0 1
1 4
0 0
0 9
21 1
0 0
0 5
12 0
0 0
0 12 11 0
0 0
0 7
13 0
0 0
0 3
19 0
0 0
0 3
1 0
0 0
0 1
6 0
0 0
0 1
2 0
0 0
0 0
0 0
0 0
0 Total 3
2 2
0 2
3 1
6 31 17 23 20 22 4
7 3
0 Total 52 86 8
0 0
0 146 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabi Hours of missing stability measurements in all s lity class:
2 tability classes:
27
Zion Nuclear Station Period of Record: October Stability Class - Extremely Stable Winds Measured at Wind Speed Wind December2011 250Ft-33Ft Delta-T (F) 35 Feet (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 1
0 1
0 0
0 1
0 2
8 10 7
7 4
0 0
0 0
0 0
1 0
1 0
0 7
4 10 10 7
24 5
0 0
1 0
1 1
0 2
1 0
9 12 20 17 14 28 5
0 0
Total 41 69 0
0 0
i1 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stability class:
1 Hours of missing stability measurements in all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class -
Extremely Unstable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 0
0 3
1 2
0 4
1 0
1 2
6 4
0 0
3 0
0 0
1 0
0 0
0 12 0
0 0
0 0
2 0
1 6
8 7
2 3
5 1
1 0
1 0
0 0
0 0*
1 1
0 0
2 0
0 3
7 2
2 5
2 0
3 6
2 0
0 0
4 6
0 0
0 0
12 5
17 6
16 0
0 0
7 2
0 0
12 40 19 18 11 100 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class -
Moderately Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 2
1 1
1 1
4 5
2 6
12 8
12 9
2 1
0 Total 0
7 18 27 12 4
68 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
all stability cl 0
asses:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class - Slightly Unstable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 1
1 2
1 1
2 0
1 3
2 2
2 3
0 5
3 0
0 0
1 3
1 4
0 1
0 0
0 0
0 1
1 4
6 2
1 1
3 0
0 0
1 0
0 0
0 0
0 0
7 5
2 4
3 5
6 6
6 0
3 0
1 3
1 1
0 4
6 6
15 5
4 4
2 1
0 4
3 4
0 0
0 6
20 0
30 0
11 2
11 2
14 0
0 0
6 2
0 0
17 41 49 20 11 138 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class - Neutral
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE 1-3 0
0 1
4-7 8-12 13-18 19-24
> 24 Total 2
10 26 29 18 85 ENE E
ESE 0
0 0
0 0
0 0
1 3
4 4
6 10 5
10 11 1
25 38 40 104 1
17 15 16 50 5
0 5
8 3
1 3
0 22 0
29 0
13 0
15 6
12 9
Ii S
2 1
7 4
9 20 13 11 62 8
1 10 25 49 35 0
16 28 14 16 2
10 29 29 22 1
121 1
75 7
99 8
78 1
81 9
112 WNW NW NNW variable Total 1
1 1
1 8
15 31 15 7
35 25 12 2
44 41 15 0
0 0
375 0
301 0
1 11 79 233 138 1137 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class -
Slightly Stable
- 250Ft-33Ft Winds Measured at 250 Feet Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW NNW Variable 4
1 0
1 0
0 9
8 14 23 26 12 12 12 12 4
0 3
3 0
1 0
0 3
9 17 30 34 22 53 19 18 3
0 0
0 1
0 0
1 1
2 16 3
9 13 17 2
0 0
76 8
5 3
2 2
3 15 24 47 75 68 47 80 52 39 8
0 Total 8
39 138 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 215 2
478 0
stability class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October -
December2011 Stability Class Moderately Stable 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
ESE SE 1-3 0
0 0
0 0
1 1
4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 1
1 0
3 1
0 0
3 2
3 5
0 0
0 1
0 0
0 0
0 0
0 2
0 1
5 0
0 1
0 0
0 0
0 0
1 0
8 1
0 0
5 7
4 SSE S
0 1
0 0
0 0
0 0
0 1
8 10 0
11 11 W
1 3
2 1
1 0
3 0
6 7
10 8
0 7
0 20 0
27 0
16 0
20 0
10 0
12 0
13 0
11 WNW NW NNW Variable 3
8 1
0 0
0 0
0 0
0 0
0 0
2 3
0 Total 3
14 48 72 10 1
148 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stabili ty class:
0 all stability classes:
27
Zion Nuclear Station Period of Record: October - December2011 Stability Class -
Extremely Stable
- 250Ft-33Ft Delta-T (F)
Winds Measured at 250 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE 1-3 0
0 0
0 4-7 8-12 13-18 19-24
> 24 Total 0
16 E
0 0
0 0
0 0
0 6
0 0
2 3
4 4
0 0
0 0
0 0
0 0
0 0
0 0
6 0
15 WSW W
WNW 0
2 0
2 1
3 0
2 1
0 13 3
6 0
1 5
0 1
3 2
0 0
4 0
0 0
0 9
3 4
0 14 0
10 NW NNW 2
4 0
0 16 Variable 0
0 Total 21 26 47 17 0
112 Hours of Hours of Hours of calm in missing missing this stability class:
0 wind measurements in this stability class:
0 stability measurements in all stability classes:
27 List of Regulatory Commitments List of Commitments to the Zion Nuclear Power Station, Units 1 and 2, 2011 Radioactive Effluent Release Report.
The following identifies those actions committed to by ZionSolutions in this document. Any other actions discussed in this submittal represent intended or planned actions by ZionSolutions. They are described to the NRC for the NRC's information, and are not Regulatory Commitments.
Commitments:
None K\\RP\\EFFLUENT\\1I AEROR NRC Commit
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2010 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 1. Type of waste and 2. Estimate of major nuclide composition
- a. Spent resins, filter sludges, evaporator bottoms, etc.
Waste Volume Class (m3)
A 0.00E+00 Activity Eslim. Error (Ci) in Activity 0.OOE+00 2.50E+01%
Waste Volume Class (m3)
B O.OOE+00 Activity 0.OOE+00 Estim. Error in Activity 2.50E+01%
Waste Class C
Volume (mE)
O.OOE+O0 Activity (Ci)
O.OOE+00 Estim. Error in Activity 2.50E+01%
Waste Class All Volume (mE) 0.00E+00 Activity (Ci)
O.OOE+00 Estim. Error in Activity 2.50E+01%
Nuclide Percent Activity Name Abundance (Ci)
H-3 0.OOE+00% 0.OOE+00 C-14 0.OOE+00% 0.OOE+00 Cr-51 0.OOE+00% 0.OOE+00 Mn-54 0.OOE+00% 0.OOE+00 Fe-55 0.OOE+00% 0.OOE+00 Fe-59 0.OOE+00% 0.OOE+00 Co-57 0.OOE+00% 0.OOE+00 Co-58 0.OOE+00% 0.OOE+00 Co-60 0.OOE+00% 0.OOE+00 Ni-59 0.OOE+00% 0.OOE+00 Ni-63 0.OOE+00% 0.00E+00 Sr-89 0.OOE+00% 0.OOE+00 Sr-90 0.OOE+00% 0.00E+00 Zr-95 0.OOE+00% 0.OOE+00 Nb-95 0.OOE+00% 0.OOE+00 Tc-99 0.OOE+00% 0.OOE+00 Ag-110m 0.OOE+00% 0.00E+00 Sn-1 13 0.OOE+00% 0.OOE+00 Sb-125 0.OOE+00% 0.OOE+00 1-129 0.OOE+00% 0.OOE+00 Cs-134 0.OOE+00% 0.OOE+00 Cs-137 0.OOE+00% 0.OOE+00 Ce-144 0.OOE+00% 0.OOE+00 Pu-238 0.OOE+00% 0.00E+00 Pu-239 0.OOE+00% O.OOE+00 Pu-241 0.OOE+00% 0.OOE+00 Pu-242 0.OOE+00% O.OOE+00 Am-241 0.OOE+00% 0.OOE+00 Cm-242 0.OOE+00% 0.OOE+00 Cm-243 0.00E+00% 0.OOE+00 Zn-95 0.OOE+00% 0.OOE+00 Nuclide Percent Activity Name Abundance (Ci)
H-3 0.OOE+00%
0.OOE+00 C-14 0.OOE+00%
0.OOE+00 Cr-51 0.OOE+00%
0.OOE+00 Mn-54 0.OOE+00%
0.OOE+00 Fe-55 0.OOE+00%
0OOE+00 Fe-59 0.OOE+00%
0.OOE+00 Co-57 0.OOE+00%
O.OOE+00 Co-58 0.OOE+00%
0.OOE+00 Co-60 0.OOE+00%
O.O0E+00 Ni-59 0.OOE+00%
O.OOE+00 Ni-63 0.OOE+00%
0.OOE+00 Sr-89 0.OOE+00%
0.OOE+00 Sr-90 O.OOE+00%
0.OOE+00 Zr-95 0.OOE+00%
O.OOE+00 Nb-95 0.OOE+00%
O.OOE+00 Tc-99 0.OOE+00%
0.00E+00 "Ag-110m 0.OOE+00%
0.OOE+00 Sn-113 0.OOE+00%
0.OOE+00 Sb-125 0.OOE+00%
0.OOE+00 1-129 0.OOE+00%
0.OOE+00 Cs-134 0.OOE+00% 0.OOE+00 Cs-137 O.OOE+00%
O.OOE+00 Ce-144 0.OOE+00% 0.OOE+00 Pu-238 0.OOE+00%
0.OOE+00 Pu-239 0.00E+00% 0.OOE+00 Pu-241 0.OOE+00%
0.00E+00 Pu-242 0.OOE+00%
0.OOE+00 Am-241 0.OOE+00% 0.OOE+00 Cm-242 0.OOE+00% 0.OOE+00 Cm-243 0.OOE+00%
0.OOE+00 Zn-95 0.OOE+00% 0.OOE+00 Nuclide Percent Activity Name Abundance (Ci)
H-3 0.OOE+00% 0.OOE+00 C-14 0.OOE+00% 0.OOE+00 Cr-51 0.OOE+00% 0.OOE+00 Mn-54 0.OOE+00% 0.OOE+00 Fe-55 O.OOE+00% 0.OOE+00 Fe-59 0.OOE+00% 0.OOE+00 Co-57 O.OOE+00% 0.OOE+00 Co-58 0.O0E+00% 0.OOE+00 Co-60 0.OOE+00% 0.OOE+00 Ni-59 0.O0E+00% 0.OOE+00 Ni-63 0.OOE+00% 0.OOE+00 Sr-89 0.OOE+00% 0.OOE+00 Sr-90 0.OOE+00% 0.OOE+00 Zr-95 0.OOE+00% 0.OOE+00 Nb-95 0.00E+00% 0.OOE+00 Tc-99 0.OOE+00% 0.OOE+00 Ag-1 10m 0.OOE+00% 0.OOE+00 Sn-113 0.OOE+00% 0.00E+00 Sb-125 0.OOE+00% 0.OOE+00 1-129 0.OOE+00% 0.OOE+00 Cs-134 0.OOE+00% 0.OOE+00 Cs-137 0.O0E+00% 0.O0E+00 Ce-144 0.00E+00% 0.OOE+00 Pu-238 0.OOE+00% 0.OOE+00 Pu-239 0.00E+00% 0.OOE+00 Pu-241 0.OOE+00% 0.OOE+00 Pu-242 0.OOE+00% 0.OOE+00 Am-241 0.OOE+00% 0.OOE+00 Cm-242 0.OOE+00% 0.OOE+00 Cm-243 0.OOE+00% 0.OOE+00 Zn-95 0.OOE+00% 0.OOE+00 Nuclide Percent Activity Name Abundance (Ci)
H-3 0.OOE+00% 0.OOE+00 C-14 0.OOE+00% 0.OOE+00 Cr-51 0.OOE+00% 0.OOE+00 Mn-54 0.OOE+00% O.OOE+00 Fe-55 0.OOE+00% 0.OOE+00 Fe-59 0.OOE+00% 0.OOE+00 Co-57 0.OOE+00% 0.OOE+00 Co-58 0.OOE+00% 0.OOE+00 Co-60 O.OOE+00% 0.OOE+00 Ni-59 0.00E+00% 0.OOE+00 Ni-63 0.OOE+00% O.OOE+00 Sr-89 0.OOE+00% 0.OOE+00 Sr-90 0.OOE+00% 0.OOE+00 Zr-95 0.OOE+00% 0.OOE+00 Nb-95 0.OOE+00% 0.OOE+00 Tc-99 0.OOE+00% 0.OOE+00 Ag-110m 0.OOE+00% 0.OOE+00 Sn-113 0.OOE+00% 0.OOE+00 Sb-125 0.OOE+00% 0.OOE+00 1-129 O.OOE+00% 0.OOE+00 Cs-134 0.OOE+00% O.OOE+00 Cs-137 O.0OE+00% 0.OOE+00 Ce-144 0.OOE+00% O.OOE+00 Pu-238 0.OOE+00% 0.OOE+00 Pu-239 0.OOE+00% 0.OOE+00 Pu-241 0.OOE+00% 0.OOE+00 Pu-242 0.OOE+00% 0.OOE+00 Am-241 0.OOE+00% 0.OOE+00 Cm-242 0.OOE+00% 0.OOE+00 Cm-243 0.OOE+00% 0.OOE+00 Zn-95 0.OOE+00% 0.OOE+00
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2011 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 1. Type of waste and 2. Estimate of major nuclide composition
- b. Dry compressible waste, contaminated equipment, etc.
Waste Volume Activity Estim. Error Class (me)
(Ci) in Activity A
8.71E+02 6.51E+00 2.50E+01%
Nuclide Percent Activity Name Abundance (Ci)
H-3 2.20E-04 1.43E-03 C-14 1.13E-04 7.35E-04 Fe-55 3.68E-02 2.40E-01 Co-60 6.35E-01 4.14E+00 Ni-59 1.75E-03 1.14E-02 Ni-63 2.22E-01 1.45E+00 Zn-65 1.52E-03 9.88E-03 Sr-89 3.66E-04 2.38E-03 Sr-90 9.95E-04 6.48E-03 Nb-94 1.60E-03 1.04E-02 Tc-99 8.23E-04 5.36E-03 Sb-125 1.44E-03 9.35E-03 1-129 8.45E-05 5.50E-04 Cs-137 9.24E-02 6.02E-01 Ce-144 9.35E-04 6.09E-03 Pu-238 2.16E-04 1.41 E-03 Pu-239 6.84E-05 4.46E-04 Pu-241 2.20E-03 1.43E-02 Pu-242 3.04E-06 1.98E-05 Am-241 5.95E-04 3.87E-03 Cm-242 7.27E-07 4.74E-06 Cm-243 2.52E-04 1.64E-03 Waste Volume Activity Estim. Error Class (m
- 3)
(Ci) in Activity B
0.OOE+00 O.OOE+00 O.OOE+00%
Nuclide Percent Activity Name Abundance (Ci)
H-3 0.OOE+00%
0.OOE+00 C-14 0.OOE+00%
0.OOE+00 Fe-55 0.OOE+00%
0.OOE+00 Co-60 0.OOE+00%
0.00E+00 Ni-59 0.OOE+00%
0.00E+00 Ni-63 0.OOE+00%
0.OOE+00 Zn-65 0.OOE+00%
0.00E+00 Sr-89 0.OOE+00%
0.00E+00 Sr-90 O.OOE+00%
0.OOE+00 Nb-94 O.OOE+00%
0.OOE+00 Tc-99 0.OOE+00%
O.OOE+00 Sb-125 O.OOE+00%
O.OOE+00 1-129 O.OOE+00%
O.OOE+00 Cs-137 0.OOE+00%
O.OOE+00 Ce-144 0.OOE+00%
O.OOE+00 Pu-238 O.OOE+00%
0.OOE+00 Pu-239 0.00E+00%
O.OOE+00 Pu-241 0.OOE+00%
0.OOE+00 Pu-242 0.OOE+00%
O.OOE+00 Am-241 O.OOE+00%
O.OOE+00 Cm-242 O.OOE+00%
0.00E+00 Cm-243 O.OOE+00%
O.OOE+00 Waste Volume Activity Estim. Error Class (M3)
(Ci) in Activity C
O.OOE+O 00.OOE+00 0.OOE+00%
Nuclide Percent Activity Name Abundance (Ci)
H-3 O.OOE+O0%
O.OOE+00 C-14 O.OOE+00%
O.OOE+00 Fe-55 O.OOE+00%
O.OOE+00 Co-60 O.OOE+00%
0.OOE+00 Ni-59 O.OOE+00%
0.OOE+00 Ni-63 O.OOE+00%
O.OOE+00 Zn-65 O.OOE+00%
O.OOE+00 Sr-89 O.OOE+00%
0.OOE+00 Sr-90 O.OOE+O0%
0.OOE+00 Nb-94 O.OOE+00%
O.OOE+00 Tc-99 O.OOE+00%
O.OOE+00 Sb-125 O.OOE+00%
O.OOE+00 1-129 O.OOE+00%
0.OOE+00 Cs-137 O.OOE+00%
0.OOE+00 Ce-144 O.OOE+00%
0.OOE+00 Pu-238 0.OOE+00%
O.OOE+00 Pu-239 O.OOE+00%
O.OOE+00 Pu-241 O.OOE+00%
0.OOE+00 Pu-242 O.OOE+00%
O.OOE+00 Am-241 O.OOE+00%
0.OOE+00 Cm-242 O.OOE+00%
0.OOE+00 Cm-243 0.OOE+00%
0.OOE+00 Waste Volume Activity Estim. Error Class (im
- 3)
(Ci) in Activity All 1.71E+02 6.51E+00 2.50E+01%
Nuclide Percent Activity Name Abundance (Ci)
H-3 2.20E-04 1.43E-03 C-14 1,13E-04 7.35E-04 Cr-51 3.68E-02 2.40E-01 Mn-54 6.35E-01 4.14E+00 Fe-55 1.75E-03 1.14E-02 Fe-59 2.22E-01 1.45E+00 Co-57 1.52E-03 9.88E-03 Co-58 3.66E-04 2.38E-03 Co-60 9.95E-04 6.48E-03 Ni-59 1.60E-03 1.04E-02 Ni-63 8.23E-04 5.36E-03 Sr-89 1.44E-03 9.35E-03 Sr-90 8.45E-05 5.50E-04 Zr-95 9.24E-02 6.02E-01 Nb-95 9.35E-04 6.09E-03 Tc-99 2.16E-04 1.41E-03 Ag-110m 6.84E-05 4-46E-04 Sn-113 2.20E-03 1.43E-02 Sb-125 3.04E-06 1.98E-05 1-129 5.95E-04 3.87E-03 Cs-134 7.27E-07 4.74E-06 Cs-137 2.52E-04 1.64E-03
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT REPORT FOR 2011 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 3. Solid Waste Disposition Number of Shipments Mode of transportation Destination Clive Disposal Facility (Bulk Waste Facility) 23 Truck Interstate 80, Exit 49, Clive UT 84029 B.
IRRADIATED FUEL SHIPMENTS No irradiated fuel shipments were performed during 2011.
C. IRRADIATED COMPONENTS, CONTROL RODS, ETC.
Number of Shipments Mode of Transportation Destination Clive Disposal Facility (Bulk Waste Facility)
Interstate 80, Exit 49, Clive UT 84029 1
Truck
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2011 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Radioactive Waste Shipments for 2011 Shipment Date Shipment Number Waste Class Container Solidification Type Agent Activity (Ci)
Volume Media Receiver (ms)
(ftP) 1st Quarter:
Sub totals:
0 0.0000000 0.000 0.00 2nd Quarter:
Sub totals:
0 0.0000000 0.000 0.00 3rd Quarter:
Disposal Sealand/
Sub totals:
15 Solid Site A
Intermodal N/A 0.0808241 665.600 23506.00 4th Quarter:
Disposal Site Sub totals:
9 Solid A
Intermodal/
Metal Container N/A 6.4322703 205.500 7257.00 Totals:
24 6.51 E+00 871.100 30763.00 Number of Shipments Activity (Ci)
Volume (M3)
Class A Class B Class C 24 0
0 6.51 E+00 0.00E+00 0.00E+00 8.71 E+02 0.00E+00 0.OOE+00
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2011 UNIT 1 & 2 (Docket Numbers 50-295 & 50-304)
ADDENDUM
- 1.
Offsite Dose Calculation Manual (ODCM)
Changes to the ODCM are required by Zion Station Permanently Defueled Technical Specification 5.6.1. and ODCM Section 12.6.3 to be submitted as part of, or concurrent with, the Annual Radioactive Effluent Release Report.
A summary of changes made to the ODCM during 2011 and an entire copy of the ODCM, current as of December 31, 2011, and required to be submitted.
- 2.
Gaseous and Liquid Waste Treatment Systems and Process Control Program Zion Station ODCM Section 12.6.4 requires major changes to the Gaseous and Liquid Waste Treatment Systems to be reported in the Annual Radioactive Effluent Release Report.
The Waste Gas Hold-up System was permanently vented. In Zion's defueled configuration this system is no longer applicable.
In Zion's defueled configuration, the charcoal iodine removal system is no longer applicable.
Due to radioactive decay and no means of production, radioactive iodine is not a concern at Zion.
- 3.
Limiting Conditions of Operation (LCOs)
Zion Station ODCM Section 12.7.2 requires explanation as to why the inoperability of liquid or gaseous monitoring instrumentation was not corrected within the time specified in the ODCM to be submitted with the Annual Radioactive Effluent Release Report.
There are no such occurrences
- 4.
Liquid Holdup Tanks and Gas Storage Tanks Zion Station ODCM Section 12.7.2 requires a description of events leading to liquid holdup tanks or gas storage tanks exceeding technical specification limits to be included in the Annual Radioactive Effluent Release Report.
The contents of the six gas decay tanks have been sampled and determined to have negligible activity. The Gas Decay Tanks have been abandoned in place.
No liquid holdup tanks exceeded the limits of Permanently Defueled Technical Specifications 5.6.3 during 2011.
K:\\RP\\EFFLUENT\\1 1AMRADDENDUMOI 1.doc
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2011 ADDENDUM
- 5.
Estimates of Total Error The following is an estimate of the total error associated with certain total values in the Annual Radioactive Effluent Release Report. The Total error is determined by calculating the square root of the sum of the squares of the individual errors.
- a.
Gaseous Effluents Sampling Error 5%
Calibration Error 10%
Counting Statistics Error 17%
Sample Volume Error 10%
Total Error 23%
- b.
Liquid Effluents Sampling Error 5%
Calibration Error 10%
Counting Statistics Error 16%
Sample Volume Error 2%
Total Error 20%
K:\\RP\\EFFLUENT\\1 1AER\\ADDENDUMOI 1.doc
ZION NUCLEAR POWER STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2011 ADDENDUM
- 5.
Estimates of Total Error The following is an estimate of the total error associated with certain total values in the Annual Radioactive Effluent Release Report. The Total error is determined by calculating the square root of the sum of the squares of the individual errors.
- a.
Gaseous Effluents Sampling Error 5%
Calibration Error 10%
Counting Statistics Error 17%
Sample Volume Error 10%
Total Error 23%
- b.
Liquid Effluents Sampling Error 5%
Calibration Error 10%
Counting Statistics Error 16%
Sample Volume Error 2%
Total Error 20%
K:ARPMEFFLUENT1 1 AER\\ADDENDUM0 11.doc Summary of Changes to the ODCM
- Changes made to the ODCM in 2011 Zion Station 2011 Offsite Dose Calculation Manual (ODCM)
Summary of Changes for Chapter 12 Revision 20 Pages/Section I
Change Summary 12-27/Table 12.4-1 Note 2 changed to specify when each building is considered unventilated.
Zion Station 2011 Offsite Dose Calculation Manual (ODCM)
Summary of Changes for Chapter 10 Revision 13 and Chapter 12 Revision 21 Pages/Section Change Summary 10-1/10.1.1 System Description is revised to describe the Unit 1 Ventilation stack as a release point from Unit 1 Containment.
10-1/10.1.2.1 Auxiliary Building Ventilation Stack Effluent Monitors is revised to reference only Unit 2 stack as an Aux Bldg effluent release point.
10-3/10.1.2.3 Containment Purge Effluent monitors is revised to describe the functions of radiation monitors 1RIA-PR49 and 2RIA-PR49A.
10-4/10.1.4 Allocation of Fuel Building Effluents to common release points is revised to describe the method of estimating noble gas releases from Unit I Ventilation stack.
10-10/Table 10-2 Table is revised to remove the Unitl Aux Bldg Exhaust fans as that release path is permanently isolated.
12-9/Bases 12.2.2.C Bases is revised to identify when the Ventilation stacks are considered available as a release path.
12-11, 12-12, 12-14, Tables is revised to delineate between Containment and Aux Bldg Operability 12-15 and 12-26,12-requirements.
27,12-28/
Tables 12.2-3, 12.2-4 and 12.4-1 12-27/Tablel2.4-1 Table is revised to define the Unventilated Containment.
Offsite Dose Calculation Manual (ODCM)
Summary of Changes for Chapter 10, Revision 12 And Chapter 12, Revision 19 Page/Section Change Summary 10-1/10.1.1 Add system description information for the Containment Purge System operation and release point for Fuel Building ventilation.
10-1/10.1.2.1 Include Unit 1 &2 Containments in monitored effluent path for AB vent stack monitors.
10-1/10.1.2.2 Deleted Fuel Building Effluent Monitor.
10-3/10.1.3.5 Removed reference for Fuel Building Exhaust Flows.
10-3/10.1.4 Removed reference for Common Release Points.
12-9/12.2.2.C Added additional information for AB release stack availability for Fuel Building and Containments.
12-1 1/Table 12.2-3 Added compensatory measures for an inoperable condition on 0RT-AR13.
notations 12-12,13/Surveillance Added compensatory action for ORT-AR13 inoperable 13 12-14/12.2-4 Table Added note 4 to ORT-AR22, removed daily channel check requirements for ORT-AR1 3, and changed source check requirement for ORT-AR1 3 from
_monthly to daily.
12-15/12.2-4 Notes Removed daily from note 3.
12-27/12.4-1 Table Added Unit 1 and 2 Containments to unVentilated building release. Note 2 changed to specify when each building is considered unventilated.
12-28/12.4-1 Notes Removed calculation for estimating release rate from AB and added requirement to estimate release rate from Fuel Building and Containments to note (i). Removed Fuel Building release rate estimate and added instructions to not require sampling of containments for noble gases and tritium to note (j).
Zion Station 2011 Offsite Dose Calculation Manual (ODCM)
Summary of Changes for Chapter 10, Revision II And Chapter 12, Revision 18 PagelSection Change Summary 10-2/Section 10.1.2.3 Removed the requirements of the Containment Particulate Monitors 1(2)RIA-PR40.
12-10/Table 12.2-3 Changed the effective Particulate Monitor for Effluent Containment Purge Section 1.A.1 and 1.A.2 or Vent from 1 (2)RIA-PR40A to 1 (2)RIA-PR49A. Changed the surveillance requirements from 61, 72 to 11 and removed footnotes 1 and 2.
12-11/Surveillance 6 Deleted Surveillance 6 and Surveillance 7.
and 7 12-12/Table 12.2-4 Changed the effective Particulate Monitor for Effluent Containment Purge Section 1.A.1 and 1.A.2 or Vent from 1 (2)RIA-PR40A to 1(2)RIA-PR49A.
12-24/Table 12.4-1 Added "Continuous Releases)"' to the Gaseous Release Type Section B "Containment Vent or Purge" and changed the Sampling Method from "Grab (b)" to "Continuous (b)(h)"; changed Frequency from "Prior to Each Release" to "Weekly(c) and Daily(a)"; and changed Analysis from "Noble Gases Principal Gamma Emitters(d)" with an LLD of 1 E-4 pCi/cc to "Particulate Principal Gamma Emitters(e)" with an LLD of 1 E-1 1 LpCi/cc.
12-24/Table 12.4-1 Added the frequency of "Daily(a)" to the "Continuous (b)(h)" sampling Section C method.
12-26/Table 12.4-1 Changed from "Deleted" to "The daily sampling requirement is applicable Table Notation (a) when 1(2)RIA-PR49A is inoperable AND decommissioning activities are in
,progress in the associated building (Containment and/or AB).
Zion Station ODCM