- ML17325B560 + (20:30:47, 7 January 2025)
- TAC:MA2435 + (20:30:48, 7 January 2025)
- ML17325B559 + (20:30:49, 7 January 2025)
- 05000315/LER-1999-006, :on 990115,personnel Identified Discrepancy Between TS 3.9.7 Impact Energy Limit & Procedure 12 Ohp 4030.STP.046.Caused by Lack of Design Basis Control.Placed Procedure 12 Ohp 4030.STP.046 on Administrative Hold + (20:30:52, 7 January 2025)
- ML17325B555 + (20:30:55, 7 January 2025)
- ML17325B551 + (20:30:56, 7 January 2025)
- ML17325B549 + (20:30:57, 7 January 2025)
- 05000315/LER-1999-009, :on 990304,as-found RHR Safety Relief Valve Lift Setpoint Greater than TS Limit Occurred.Cause Investigation for Condition Has Not Been Completed.Update to LER Will Be Submitted,Upon Completion of Investigation + (20:30:58, 7 January 2025)
- ML17325B544 + (20:31:00, 7 January 2025)
- ML17325B543 + (20:31:01, 7 January 2025)
- IR 05000315/1999005 + (20:31:04, 7 January 2025)
- ML17325B540 + (20:31:06, 7 January 2025)
- ML17325B532 + (20:31:09, 7 January 2025)
- ML17325B539 + (20:31:09, 7 January 2025)
- ML17325B530 + (20:31:10, 7 January 2025)
- ML17325B529 + (20:31:11, 7 January 2025)
- ML17325B527 + (20:31:12, 7 January 2025)
- ML17325B524 + (20:31:13, 7 January 2025)
- ML17325B526 + (20:31:13, 7 January 2025)
- 05000316/LER-1999-001, :on 960610,degraded Component Cooling Water Flow to Containment Main Steam Line Penetrations,Identified on 990226.Caused by Inadequate Understanding of Design Basis.Additional Investigations Ongoing + (20:31:15, 7 January 2025)
- ML17325B518 + (20:31:17, 7 January 2025)
- ML17325B517 + (20:31:19, 7 January 2025)
- 05000315/LER-1999-007, :on 981020,calculations Showed That Divider Barrier Between Upper & Lower Containment Vols Were Overstressed.Engineers Are Currently Working on Analyses of Loads & Stress on Enclosures + (20:31:20, 7 January 2025)
- ML17325B514 + (20:31:21, 7 January 2025)
- ML17325B510 + (20:31:27, 7 January 2025)
- IR 05000315/1999001 + (20:32:03, 7 January 2025)
- ML17325B507 + (20:32:04, 7 January 2025)
- 05000315/LER-1999-005, :on 940512,determined That RT Breaker Manual Actuations During Rod Drop Testing Were Not Previously Reported.Caused by Lack of Training.Addl Corrective Actions,Including Preventative Actions May Be Developed + (20:32:11, 7 January 2025)
- IR 05000315/1999002 + (20:32:16, 7 January 2025)
- ML17325B469 + (20:32:17, 7 January 2025)
- ML17325B468 + (20:32:18, 7 January 2025)
- ML17325B465 + (20:32:19, 7 January 2025)
- ML17325B467 + (20:32:19, 7 January 2025)
- ML17325B464 + (20:32:20, 7 January 2025)
- ML17325B462 + (20:32:21, 7 January 2025)
- ML17325B463 + (20:32:21, 7 January 2025)
- ML17325B461 + (20:32:22, 7 January 2025)
- ML17325B460 + (20:32:23, 7 January 2025)
- ML17325B459 + (20:32:24, 7 January 2025)
- 05000315/LER-1999-003, :on 990107,CR Pressurization Sys Surveillance Test Did Not Test Sys in Normal Operating Condition.Caused by Failure to Recognize Door 12DR-AUX415 as Part of CR Pressure Boundary.Performed Walkdown of Other Doors + (20:32:25, 7 January 2025)
- ML17325B454 + (20:32:27, 7 January 2025)
- ML17325B453 + (20:32:27, 7 January 2025)
- ML17325B452 + (20:32:28, 7 January 2025)
- ML17325B449 + (20:32:29, 7 January 2025)
- ML17325B451 + (20:32:29, 7 January 2025)
- ML17325B443 + (20:32:30, 7 January 2025)
- TAC:80123 + (20:32:31, 7 January 2025)
- ML17325B442 + (20:32:32, 7 January 2025)
- ML17325B441 + (20:32:33, 7 January 2025)
- TAC:80615 + (20:32:34, 7 January 2025)
- ML17325B439 + (20:32:35, 7 January 2025)