Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000400/LER-1987-055, :on 870917,containment Integrity & Tech Spec 3.6.1.3,Action a Violated.Caused by Personnel Error. Personnel Being Trained on Proper Use of Containment Personnel Access Doors + (12:16:55, 7 January 2025)
- 05000400/LER-1987-054, :on 870915,determined That More Limiting Single Failure Might Exist & on 870916,two Addl Potential Failure Modes Identified & Plant Shut Down.Caused by Design Error. Solid State Protection Sys Modified + (12:16:57, 7 January 2025)
- ML18004B965 + (12:16:58, 7 January 2025)
- ML18004B964 + (12:16:59, 7 January 2025)
- ML18004B962 + (12:17:03, 7 January 2025)
- ML18004B961 + (12:17:04, 7 January 2025)
- IR 05000400/1987036 + (12:17:07, 7 January 2025)
- ML18004B958 + (12:17:09, 7 January 2025)
- IR 05000400/1987035 + (12:17:11, 7 January 2025)
- ML18004B955 + (12:17:13, 7 January 2025)
- 05000400/LER-1987-050, :on 870830,RCS Unidentified Leakage Exceeded 1 Gallon Per Minute & on 870831 Insp Showed Evidence of Minor Leaks Due to Normal Wear.Caused by Equipment Failure. Valve Packing Repairs Initiated + (12:17:16, 7 January 2025)
- ML18004B953 + (12:17:17, 7 January 2025)
- ML18004B952 + (12:17:18, 7 January 2025)
- ML18004B951 + (12:17:18, 7 January 2025)
- ML18004B947 + (12:17:20, 7 January 2025)
- ML18004B945 + (12:17:21, 7 January 2025)
- ML18004B946 + (12:17:21, 7 January 2025)
- 05000400/LER-1987-043, :on 870820,discovered That Six Manual Isolation Valves Not Included in Operations Surveillance Test OST-1029.Caused by Personnel Error.Test Revised to Include Valves in Monthly Verification of Position + (12:17:23, 7 January 2025)
- IR 05000400/1987014 + (12:17:25, 7 January 2025)
- ML18004B941 + (12:17:26, 7 January 2025)
- ML18004B940 + (12:17:29, 7 January 2025)
- ML18004B939 + (12:17:30, 7 January 2025)
- ML18004B938 + (12:17:31, 7 January 2025)
- ML18004B937 + (12:17:32, 7 January 2025)
- 05000400/LER-1987-048, :on 870811,failure to Take 9:30 Am Reading of Axial Flux Difference (Afd) as Required by Tech Specs Discovered.Caused by Personnel Error.Operator Disciplined. Addl Guidance Being Provided to Operators + (12:17:33, 7 January 2025)
- ML18004B935 + (12:17:34, 7 January 2025)
- IR 05000400/1987020 + (12:17:35, 7 January 2025)
- ML18004B933 + (12:17:37, 7 January 2025)
- ML18004B932 + (12:17:39, 7 January 2025)
- ML18004B930 + (12:17:40, 7 January 2025)
- IR 05000400/1987032 + (12:17:44, 7 January 2025)
- ML18004B927 + (12:17:46, 7 January 2025)
- 05000400/LER-1987-047, :on 870804-05,auxiliary Feedwater Actuations Occurred Due to Trips of Main Feedwater Pump 1A.Caused by Discharge Pressure Switches Out of Calibr.Discharge Pressure Switches Recalibr + (12:17:47, 7 January 2025)
- 05000400/LER-1987-041, :on 870804,restoration Alignment on Clearance for Placing Dryer 1B Back Into Svc Incorrect.Caused by Personnel Error.Valve Lineup for Instrument Air Dryer 1B Put Into Correct Configuration + (12:17:49, 7 January 2025)
- ML18004B923 + (12:17:50, 7 January 2025)
- ML18004B921 + (12:17:51, 7 January 2025)
- ML18004B922 + (12:17:51, 7 January 2025)
- ML18004B920 + (12:17:52, 7 January 2025)
- IR 05000400/1987025 + (12:17:59, 7 January 2025)
- ML18004B916 + (12:18:00, 7 January 2025)
- ML18004B915 + (12:18:01, 7 January 2025)
- ML18004B914 + (12:18:02, 7 January 2025)
- 05000400/LER-1987-046, :on 870722,main Feedwater Pump B Tripped Due to Low Flow Resulting in Automatic Start of Auxiliary Feedwater Pumps.Caused by Loose Linkage on Recirculation Valve Due to Vibration.Valve Repaired.Procedures Changed + (12:18:05, 7 January 2025)
- ML18004B911 + (12:18:07, 7 January 2025)
- IR 05000400/1987030 + (12:18:19, 7 January 2025)
- ML18004B908 + (12:18:20, 7 January 2025)
- ML18004B907 + (12:18:21, 7 January 2025)
- ML18004B906 + (12:18:22, 7 January 2025)
- ML18004B905 + (12:18:23, 7 January 2025)
- ML18004B904 + (12:18:24, 7 January 2025)
- 05000400/LER-1987-045, :on 870716,RCS Pressure Fell Below Accumulator Pressure,Initiating Partial Injection of All Three Accumulators.Caused by Reactor Operator Error.Operating Shift Disciplined & Procedure Revised + (12:18:26, 7 January 2025)