- 05000346/LER-1978-025-03, /03L-0:on 780304,RCS Leakage Found Greater than 1 Gallon Per Minute.Leakage Cause Undetermined.Leakages Processed Through Normal Containment Sump.Unidentified RCS Leakage Reduced Below 1 Gallon Per Minute in 5.5-h + (11:49:14, 31 December 2024)
- ML19329B930 + (11:49:15, 31 December 2024)
- ML19329B929 + (11:49:16, 31 December 2024)
- ML19329B928 + (11:49:17, 31 December 2024)
- 05000346/LER-1978-033-03, /03L-1:on 780325 Steam,Generator 1-2 Level Found Increasing After Closing Startup Feedwater Valve,Exceeding Max Limit.Main Feedwater Block Valve FW 779 Closed Manually, Controling SG 1-2 Level + (11:49:18, 31 December 2024)
- ML19329B925 + (11:49:19, 31 December 2024)
- ML19329B923 + (11:49:19, 31 December 2024)
- 05000346/LER-1978-025, Forwards LER 78-025/03L-0 + (11:49:21, 31 December 2024)
- ML19329B918 + (11:49:22, 31 December 2024)
- ML19329B919 + (11:49:22, 31 December 2024)
- 05000346/LER-1978-033, Forwards LER 78-033/03L-1 + (11:49:24, 31 December 2024)
- ML19329B915 + (11:49:25, 31 December 2024)
- ML19329B912 + (11:49:26, 31 December 2024)
- ML19329B909 + (11:49:27, 31 December 2024)
- ML19329B910 + (11:49:27, 31 December 2024)
- 05000346/LER-1977-017-01, /01T-0:on 771020,both Auxiliary Feed Pump Suctions Lined Up to Deaerator Storage Tanks W/O Cooling Water Supply Shifting to Svc Water,Resulting in Water Greater than 200 F as Cooling Water for Auxiliary Feed Pump Bearings + (11:49:29, 31 December 2024)
- ML19329B904 + (11:49:31, 31 December 2024)
- 05000346/LER-1978-026-03, /03L-0:on 780309,radiation Monitor Re 5029 Found Inoperable Due to Low Sample flow.12 Previous Radiation Monitor Inoperabilities Not Reported.Caused by Pump Motor Bearing Seizure Due to High Ambient Temp + (11:49:32, 31 December 2024)
- ML19329B901 + (11:49:33, 31 December 2024)
- ML19329B900 + (11:49:34, 31 December 2024)
- ML19329B898 + (11:49:35, 31 December 2024)
- ML19329B896 + (11:49:35, 31 December 2024)
- 05000346/LER-1978-026, Forwards LER 78-026/03L-0 + (11:49:36, 31 December 2024)
- ML19329B892 + (11:49:37, 31 December 2024)
- ML19329B891 + (11:49:38, 31 December 2024)
- ML19329B890 + (11:49:39, 31 December 2024)
- ML19329B889 + (11:49:39, 31 December 2024)
- ML19329B887 + (11:49:40, 31 December 2024)
- ML19329B885 + (11:49:41, 31 December 2024)
- 05000346/LER-1977-116-03, /03L-0:on 771228,during Auxiliary Feed Pump Monthly Surveillance Test,Turbine 1-2 Speed Control Lost & Declared Inoperable.Caused by Design Deficiency.Blown Control Power Fuse & Both Relays Replaced & Modified + (11:49:42, 31 December 2024)
- ML19329B882 + (11:49:44, 31 December 2024)
- ML19329B879 + (11:49:45, 31 December 2024)
- 05000346/LER-1977-116, Forwards LER 77-116/03L-0 + (11:49:46, 31 December 2024)
- ML19329B875 + (11:49:51, 31 December 2024)
- ML19329B874 + (11:49:51, 31 December 2024)
- 05000346/LER-1978-022-03, /03L-0:on 780223,flow Transmitter FTRC1A3 Found Inoperable.Caused by Defective Flow Transmitter Amplifier. Amplifier Replaced & Flow Transmitter FTRC1A3 Returned to Svc on 780226 + (11:49:53, 31 December 2024)
- ML19329B872 + (11:49:54, 31 December 2024)
- ML19329B871 + (11:49:55, 31 December 2024)
- ML19329B869 + (11:49:56, 31 December 2024)
- ML19329B867 + (11:49:57, 31 December 2024)
- 05000346/LER-1978-023-03, /03L-0:on 780224,temp Indication for Reactor Protection Sys Channel 2 Spiked Tripping Channel & Shut Down Reactor.Caused by Faulty Connector Due to Dirt on Contacts. Channel 2 Temp String Modules Removed & Connectors Cleaned + (11:49:59, 31 December 2024)
- ML19329B865 + (11:50:00, 31 December 2024)
- ML19329B864 + (11:50:01, 31 December 2024)
- ML19329B862 + (11:50:02, 31 December 2024)
- 05000346/LER-1978-020-03, /03L-0:on 780210,reactor Protection Sys Channel 3 Hot Leg Temp String TI-RC3B4 Declared Inoperable.Caused by Loose Wire Connection.Loose Terminal at Temp Element Tightened,Rendering TI-RC3B4 Operable + (11:50:04, 31 December 2024)