Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20002B149 + (20:54:58, 23 December 2024)
- ML20002B148 + (20:54:59, 23 December 2024)
- ML20002B147 + (20:55:00, 23 December 2024)
- ML20002B146 + (20:55:02, 23 December 2024)
- IR 05000424/1980014 + (20:55:03, 23 December 2024)
- ML20002B143 + (20:55:04, 23 December 2024)
- IR 05000321/1980040 + (20:55:05, 23 December 2024)
- ML20002B141 + (20:55:07, 23 December 2024)
- ML20002B139 + (20:55:08, 23 December 2024)
- ML20002B138 + (20:55:09, 23 December 2024)
- IR 05000416/1980021 + (20:55:10, 23 December 2024)
- ML20002B136 + (20:55:12, 23 December 2024)
- ML20002B134 + (20:55:13, 23 December 2024)
- ML20002B133 + (20:55:14, 23 December 2024)
- ML20002B132 + (20:55:15, 23 December 2024)
- ML20002B131 + (20:55:16, 23 December 2024)
- 05000295/LER-1980-049-03, /03L-0:on 801029,component Cooling Liquid Monitor 1RE-017 Had No Response to Installed Check Sources.Caused by Bad Electrical Contacts Between Detector & Socket Assembly. Socket Replaced,Monitor Calibr & Tested + (20:55:18, 23 December 2024)
- 05000219/LER-1980-050-03, /03L-0:on 801106,containment Spray Sys Drywell Pressure Switches IP-15A,IP-15B,IP-15C & IP-15D Found to Trip at Greater than Allowable Tech Spec Values.Caused by Instrument Repeatability.Switches Adjusted + (20:55:23, 23 December 2024)
- 05000277/LER-1980-029-01, /01T-0:on 801113,reactor Core Isolation Cooling Sys Declared Inoperable.Caused by Turbine Trip Valve Switch Being Out of Adjustment.Switch Readjusted & Tested + (20:55:25, 23 December 2024)
- 05000219/LER-1980-050, Forwards LER 80-050/03L-0 + (20:55:27, 23 December 2024)
- 05000277/LER-1980-029, Forwards LER 80-029/01T-0 + (20:55:28, 23 December 2024)
- 05000368/LER-1980-076-03, /03L-0:on 801103,emergency Feedwater Pump 2P7A Found Inoperable Due to Broken Terminal Connection Screw. on 800723,pump Declared Inoperable Due to Loss of Control Power.Caused by Excessive Use & Incorrect Recorder Hookup + (20:55:30, 23 December 2024)
- 05000295/LER-1980-049, Forwards LER 80-049/03L-0 + (20:55:33, 23 December 2024)
- 05000265/LER-1980-032-01, /01T-0:on 801116,HPCI Sys Declared Inoperable. Caused by Oil Leak on HPCI Stop Valve Cover.Cover Replaced & Tested + (20:55:34, 23 December 2024)
- 05000277/LER-1980-028-03, /03L-0:on 801121,setpoint of Main Steam Low Pressure Switch Ps 2-2-134B Dropped Below Tech Spec Requirements.Caused by Drift of Barksdale Model B2T-A12SS. Instrument Recalibr & Tested + (20:55:36, 23 December 2024)
- 05000368/LER-1980-076, Forwards LER 80-076/03L-0 + (20:55:38, 23 December 2024)
- 05000265/LER-1980-031-01, /01T-0:on 801116,reactor Core Isolation Cooling Discharge Isolation Valve MO-2-1301-49 Would Not Open from Control Room.Caused by Faulty Torque Switch.Torque & Limit Switches Cleaned,Checked & Exercised + (20:55:40, 23 December 2024)
- 05000265/LER-1980-032, Forwards LER 80-032/01T-0 + (20:55:41, 23 December 2024)
- ML20002B112 + (20:55:43, 23 December 2024)
- ML20002B111 + (20:55:44, 23 December 2024)
- 05000265/LER-1980-031, Forwards LER 80-031/01T-0 + (20:55:45, 23 December 2024)
- 05000304/LER-1980-027-03, /03L-0:on 801029,channel 2L-461 Found Out of Tolerance.Caused by Zero Shift on Xmtr 2L-461.Adjustments Made to Xmtr & Channel Returned to Svc + (20:55:49, 23 December 2024)
- ML20002B106 + (20:55:51, 23 December 2024)
- ML20002B104 + (20:55:53, 23 December 2024)
- ML20002B103 + (20:55:54, 23 December 2024)
- 05000304/LER-1980-027, Forwards LER 80-027/03L-0 + (20:55:56, 23 December 2024)
- ML20002B096 + (20:55:59, 23 December 2024)
- ML20002B095 + (20:56:01, 23 December 2024)
- ML20002B093 + (20:56:03, 23 December 2024)
- ML20002B091 + (20:56:04, 23 December 2024)
- ML20002B090 + (20:56:07, 23 December 2024)
- ML20002B086 + (20:56:09, 23 December 2024)
- ML20002B084 + (20:56:10, 23 December 2024)
- ML20002B085 + (20:56:10, 23 December 2024)
- 05000265/LER-1980-030-03, /03L-0:on 801031,primary Containment Valve AO-2-1601-63 Required 30-s to Close.Caused by Malfunction of Pilot Solenoid SO-2-1601-71.Solenoid Replaced & Tested + (20:56:12, 23 December 2024)
- ML20002B082 + (20:56:12, 23 December 2024)
- ML20002B080 + (20:56:14, 23 December 2024)
- ML20002B081 + (20:56:14, 23 December 2024)
- ML20002B079 + (20:56:15, 23 December 2024)
- ML20002B078 + (20:56:15, 23 December 2024)
- ML20002B076 + (20:56:16, 23 December 2024)