Informs of Review of Draft Bnwl Rept on Facility Chemical Cleaning. Recommends Rept Be Revised to Include Attached Comments
ML20002B112
Person / Time
Site: Dresden 
Issue date: 10/03/1978
From: Jun Lee
Office of Nuclear Reactor Regulation
To: Cwalina G
Office of Nuclear Reactor Regulation
References
FOIA-80-550 NUDOCS 8012090449
Download: ML20002B112 (2)


Text

/

our

![3[73 UNITED STATES o,

8f

'j NUCLEAR REGULATORY COMMisslON 3 g(gf,.. e WAsm NG TON, 0. C. 20555 y'h(/

007 3 REC'D MEMORANDUM FOR: g Cwalina, Environmental Evaluation Branch 00R FROM:

J. Y. Lee, Effluent Treatment Systems Branch OSE THRU:

R. L. Bangart, Leader Effluent Treatment Systems Branch, OSE

SUBJECT:

REVIEW OF DRAFT PNL REPORT ON ORESDEN, UNIT NO. 1, CHEMICAL CLEANING We have reviewed the PNL draft report on the Dresden, Unit No. 1, Chemical Cleaning and our comments are enclosed. The report should include an independent evaluation of the gaseous, liquid and solid source terms re-

.e sulting from Dresden chemical cleaning and a discussion of the compatibility ~

of such source terms witn the proposed decontamination radwaste treatment facility.

h-J. Y. Lee Effluent Treatment Systems Branch Division of Site Safety and Environmental Analysis

Enclosure:

ETSB Comments cc:

R. Vollmer L. Barrett B. Grimes G. Knighton P. O'Connor V. Noonan D. Solberg P. Stoddart J. Collins t

8012000YN

[

o e,

ETSB COMMENTS ON PNL DRAFT REPORT ON DRESDEN, UNIT NO. 1 CHEMICAL CLEANING 1.

The report appears too general in treating decont, ninatic.) chemical cleasing at Dresden and lacks any specific information and/or evaluatiot,. We recommend that the report be revised to include more detail.

2.

Page 5, 2nd Paragraoh The capability and need for solidification of liquid radwastes generated from chemical cleaning should also be identified and evaluated during the early planning of chemical cle'aning. Com-patibility of spent solvent and solidification reagents should be addressed in more detail in the report.

3.

Page 6 This section should include an independent evaluation of the gaseous, liquid and solid radwaste source terms resulting from chemical cle ling and compatibility of such source terms with the proposed decontamination radwaste treatment facility.

~

9 m

.