f p'# " %,,
UNITED STATES NUCLEAR REGULATORY COMMISSION j
i wAsmNoTON, D. C. 20555 a
f November 21, 1980 j
Docket No. 50-213 ijj LS05-80-11-029 y
Mr. W. G. Counsil. Senior Vice President 2
Nuclear Engineering and Operations j
Connecticut Yankee Atomic Power Company l1 g
Post Office Box 270 u
Hartford, Connecticut 06101
Dear Mr. Counsil:
In our letter to you dated September 30, 1980, we requested that you connit to installing an override-to-close capability on your pressurizer power operated relief valves (PORV) by October 30, 1980.
By letter dated October 24, 1980, and in telephone convers3tions with the staff on October 29, 1980, you agreed that the changes we requested should be made, but you disagreed with the schedule. We have considered your arguments and have concluded that an innediate plant shutdown to correct the deficiency is unwarranted.
We have also concluded that your commitment to install and test the new switches for the PORVs prior to startup from the next cold shutdown is acceptable.
Sincerely, e is.. Crutchfield, C 'ef Operating Reactors Bran
- 5 Division of Licensing cc: See next page 8012C'90
Mr. W. G. Counsil November 21, 1980 cc:
Day, Berry & Howard U. S. Environnental Protection Counselors at Law Agency One Constitution Plaza Region 1 Office Hartford, Connecticut 06103 ATTN: EIS COORDINATOR JFK Federal Building Superintendent Boston, Massachusetts 02203 Haddam Neck Plant RFD #1 Resident inspector Post Office Box 127E Haddam Neck Nuclear Power Station East Hampton, Connecticut 06424 c/o U. S. NRC East Haddam Post Office Mr. James R. Himmelwright East Haddam, Connecticut 06423 Northeast Utilities Service Cocpany P. O. Box 270 R. E. Schaffstall, Executive Director Hartford, Connecticut 06101 for SEP Owners Group 1747 Pennsylvania Avenue, NW Russell Library Washington, D.C.
20006 119 Broad Street Middletown, Connecticut 06457 Board of Selectmen Town Hall Haddam, Connecticut 06103 Connecticut Energy Agency ATTN: Assistant Director Research and Policy Development Department of Planning and Energy Policy 20 Grand Street Hartford, Connecticut 06106 Director, Criteria and Standards Division Office of Radiation Programs (ANR-460)
U. S. Environmental Protection Agency Washington, D. C.
20460 8