- ML20005D737 + (13:55:57, 23 December 2024)
- TAC:73391 + (13:55:57, 23 December 2024)
- ML20005D736 + (13:55:59, 23 December 2024)
- 05000327/LER-1989-026-01, :on 891107,Limiting Condition for Operation 3.0.3 Entered as Result of More than One Rod Position Indicator (RPI) Per Bank Being Inoperable.Caused by Lack of Preventive Maint.Rpis Adjusted + (13:56:00, 23 December 2024)
- 05000328/LER-1989-014-03, :on 891110 & 11,containment Ventilation Isolations Occurred.Caused by Personnel Error.Procedure to Be Issued for Use While Venting Sys Known or Suspected to Contain Radioactive Noble Gases + (13:56:02, 23 December 2024)
- ML20005D733 + (13:56:03, 23 December 2024)
- ML20005D732 + (13:56:04, 23 December 2024)
- ML20005D730 + (13:56:06, 23 December 2024)
- IR 05000382/1989027 + (13:56:08, 23 December 2024)
- ML20005D727 + (13:56:10, 23 December 2024)
- ML20005D725 + (13:56:11, 23 December 2024)
- ML20005D723 + (13:56:12, 23 December 2024)
- ML20005D722 + (13:56:13, 23 December 2024)
- ML20005D721 + (13:56:14, 23 December 2024)
- ML20005D719 + (13:56:16, 23 December 2024)
- IR 05000285/1989038 + (13:56:35, 23 December 2024)
- ML20005D717 + (13:56:37, 23 December 2024)
- ML20005D715 + (13:56:38, 23 December 2024)
- TAC:72082 + (13:56:39, 23 December 2024)
- ML20005D714 + (13:56:41, 23 December 2024)
- ML20005D713 + (13:56:42, 23 December 2024)
- ML20005D711 + (13:56:42, 23 December 2024)
- ML20005D710 + (13:56:43, 23 December 2024)
- ML20005D709 + (13:56:44, 23 December 2024)
- 05000282/LER-1989-018, :on 891024,25,31 & 1112,control Room Received High Radiation Alarm Which Initiated Automatic Start of Auxiliary Bldg Special Ventilation Sys.Caused by Radiation Monitor Spikes.Monitor Modules Replaced + (13:56:47, 23 December 2024)
- ML20005D705 + (13:56:50, 23 December 2024)
- ML20005D704 + (13:56:51, 23 December 2024)
- ML20005D701 + (13:56:56, 23 December 2024)
- ML20005D697 + (13:56:57, 23 December 2024)
- ML20005D699 + (13:56:57, 23 December 2024)
- ML20005D696 + (13:56:59, 23 December 2024)
- ML20005D690 + (13:57:03, 23 December 2024)
- ML20005D688 + (13:57:04, 23 December 2024)
- ML20005D687 + (13:57:06, 23 December 2024)
- ML20005D686 + (13:57:08, 23 December 2024)
- ML20005D685 + (13:57:09, 23 December 2024)
- ML20005D683 + (13:57:10, 23 December 2024)
- 05000368/LER-1989-005, :on 890518 & 25,damping Board Removed from Penetration Containing Cable Tray.On 890531,voids Noted in Penetration Seals.Caused by Erroneous Vendor Procedures. Penetrations Restored & Procedures Revised + (13:57:12, 23 December 2024)
- 05000457/LER-1989-007-09, :on 891110,w/auxiliary Feedwater Pump 2B Pump Control Switch in Pull Out Per Stated Reasons,Automatic Initiation of Pump Sys Unavailable for 6 Minutes.Caused by Procedural Deficiency.Keys to Be Color Coded + (13:57:14, 23 December 2024)
- ML20005D679 + (13:57:15, 23 December 2024)
- 05000370/LER-1989-003-01, :on 890406,reactor Trip Occurred Because of Failure of Positioner for Steam Generator 2C Main Feedwater Regulating Valve.Positioner Bellows Replaced + (13:57:16, 23 December 2024)
- 05000370/LER-1989-010-01, :on 890905,leak Occurred on Containment Spray HX 2A After Valve Stroke Timing.Caused by Valve Stroking Procedure Being Deficient & Lack of Attention to Detail. Procedures to Be Revised & Work Load Spread + (13:57:18, 23 December 2024)
- 05000370/LER-1989-012-04, :on 891108,890726,27 & 0829,diesel Generator 2B Valid Failures Discovered.Caused by Mgt Deficiency. Operations Mgt Procedure Omp 2-6 Will Be Revised + (13:57:22, 23 December 2024)
- ML20005D673 + (13:57:23, 23 December 2024)
- ML20005D672 + (13:57:24, 23 December 2024)
- ML20005D671 + (13:57:25, 23 December 2024)
- ML20005D668 + (13:57:26, 23 December 2024)
- IR 05000029/1989019 + (13:57:28, 23 December 2024)
- ML20005D664 + (13:57:30, 23 December 2024)
- 05000412/LER-1989-027, :on 891106,Train a Svc Water Pump Seal Water Supply Automatically Transferred to Backup Supply Due to Low Pressure.Caused by Seal Water Normal Supply Inadvertently Isolating While de-energizing.Manual Revised + (13:57:32, 23 December 2024)
- 05000373/LER-1989-026-01, :on 891106,inadvertent Primary Containment Isolation Actuation Occurred While Clearing out-of-svc. Caused by Inadequate Logic Setup During Mod Installation. Trip Status & Output Switches Repositioned + (13:57:34, 23 December 2024)