- 05000346/LER-1982-002, Forwards LER 82-002/03L-0 + (02:15:44, 20 December 2024)
- ML20040F327 + (02:15:45, 20 December 2024)
- ML20040F324 + (02:15:46, 20 December 2024)
- ML20040F322 + (02:15:47, 20 December 2024)
- 05000293/LER-1981-065-03, /03L-0:on 811230,during Investigation of Failure of MSIV AO-203-2A,discovered Two hold-down Bolts on Poppet W/O Lock Plates.Caused by Failure to Follow Procedures During Previous Valve Overhaul + (02:15:48, 20 December 2024)
- 05000368/LER-1981-034-99, Internal Damage Discovered on Emergency Feedwater Pump Turbine Steam Supply Check Valves 2MS-39A & 2MS-39B.Caused by Use of Wire Instead of Pin to Hold Disk Stud Retainer Nut on + (02:15:50, 20 December 2024)
- ML20040F317 + (02:15:51, 20 December 2024)
- ML20040F319 + (02:15:51, 20 December 2024)
- ML20040F316 + (02:15:52, 20 December 2024)
- 05000293/LER-1981-065, Forwards LER 81-065/03L-0 + (02:15:53, 20 December 2024)
- 05000368/LER-1981-034, Forwards Updated LER 81-034/99X-1 + (02:15:55, 20 December 2024)
- ML20040F311 + (02:15:57, 20 December 2024)
- 05000336/LER-1981-044-03, /03L-0:on 811229,while in Mode 6,radiation Monitors 8262A,8262B & 8123B Were inoperable.De-energizing of Channel C Caused 8123B to Become Inoperable.Monitors 8262A & 8262B Removed from Svc for Repair + (02:15:58, 20 December 2024)
- ML20040F309 + (02:15:59, 20 December 2024)
- ML20040F308 + (02:16:00, 20 December 2024)
- ML20040F307 + (02:16:01, 20 December 2024)
- 05000313/LER-1982-001-03, /03L-0:on 820112,RCS Leak Rate Calculation Indicated Leak Rate of 1.433 Gpm from Flange for Vent Line for Reactor Coolant Pump P32C Seal Cavity Pressure Sensing Line.Caused by Loose Flange Bolts + (02:16:03, 20 December 2024)
- ML20040F303 + (02:16:04, 20 December 2024)
- ML20040F302 + (02:16:05, 20 December 2024)
- ML20040F301 + (02:16:06, 20 December 2024)
- 05000313/LER-1982-001, Forwards LER 82-001/03L-0 + (02:16:07, 20 December 2024)
- ML20040F296 + (02:16:12, 20 December 2024)
- ML20040F295 + (02:16:13, 20 December 2024)
- ML20040F294 + (02:16:14, 20 December 2024)
- ML20040F293 + (02:16:15, 20 December 2024)
- 05000336/LER-1981-044, Forwards LER 81-044/03L-0 + (02:16:17, 20 December 2024)
- ML20040F290 + (02:16:19, 20 December 2024)
- 05000320/LER-1981-034-01, /01L-0:on 811201,incore Thermocouple F-12 Declared Inoperable.Circuitry Problem Identified & Corrected.Caused by Reversed Polarity.Surveillance Procedure 4302-R4 Amended to Require post-surveillance Evaluation + (02:16:20, 20 December 2024)
- ML20040F288 + (02:16:24, 20 December 2024)
- ML20040F287 + (02:16:24, 20 December 2024)
- ML20040F286 + (02:16:25, 20 December 2024)
- ML20040F285 + (02:16:26, 20 December 2024)
- ML20040F284 + (02:16:27, 20 December 2024)
- ML20040F283 + (02:16:28, 20 December 2024)
- ML20040F282 + (02:16:29, 20 December 2024)
- ML20040F277 + (02:16:33, 20 December 2024)
- ML20040F279 + (02:16:33, 20 December 2024)
- ML20040F276 + (02:16:34, 20 December 2024)
- IR 05000295/1981023 + (02:16:35, 20 December 2024)
- ML20040F273 + (02:16:37, 20 December 2024)
- ML20040F272 + (02:16:39, 20 December 2024)
- IR 05000309/1981030 + (02:16:40, 20 December 2024)
- PNO-III-82-008B, util Has Directed Reinstatement of Two Electrical QC Inspectors Who Were Dismissed by Baldwin Associates.Inspectors Were Allegedly Fired for Providing Info Re Intimidation to NRC + (02:16:42, 20 December 2024)
- ML20040F268 + (02:16:43, 20 December 2024)
- ML20040F267 + (02:16:44, 20 December 2024)
- IR 05000010/1981018 + (02:16:49, 20 December 2024)
- ML20040F262 + (02:16:51, 20 December 2024)
- ML20040F261 + (02:16:52, 20 December 2024)
- ML20040F259 + (02:16:53, 20 December 2024)
- ML20040F258 + (02:16:55, 20 December 2024)
- PNO-IV-82-004, on 820203,licensee Reported Instantaneous Release of About 3 Mci/Second While Performing Vol Control Tank & Pressurizer Steam Space Sampling.Sampling Revealed Waste Gaseous Products Release to Be Mostly Rb-88 + (02:16:57, 20 December 2024)