- ML20042A568 + (23:48:22, 19 December 2024)
- ML20042A567 + (23:48:22, 19 December 2024)
- ML20042A566 + (23:48:23, 19 December 2024)
- ML20042A565 + (23:48:24, 19 December 2024)
- 05000261/LER-1982-002, Forwards LER 82-002/03L-0 + (23:48:25, 19 December 2024)
- 05000316/LER-1981-067, Forwards Updated LER 81-067/03X-1 + (23:48:27, 19 December 2024)
- 05000323/LER-1981-002, Interim Deficiency Rept Re Inadequate Design of Sys Contained in Annulus Area of Containment Bldg,Initially Reported 811105.Further Info of Progress Is Identified in Suppls to LER 81-002 + (23:48:29, 19 December 2024)
- ML20042A560 + (23:48:30, 19 December 2024)
- 05000346/LER-1982-009-03, /03L-0:on 820209 & 0217,door 107 Was Found Blocked Open.Cause of First Incident Was Design Deficiency.Second Finding Caused by Personnel Error.Orientation & Requalification Classes & Contractor Classes Initiated + (23:48:32, 19 December 2024)
- 1CAN038204, Advises of Incorrect Statement in Util That HPI Safe End Weld Areas Were Inspected Using Radiographic Technique in 1977.Dye Penetrant Was Actual Insp Technique + (23:48:33, 19 December 2024)
- IR 05000315/1981022 + (23:48:35, 19 December 2024)
- ML20042A553 + (23:48:36, 19 December 2024)
- ML20042A555 + (23:48:36, 19 December 2024)
- PLA-1032, Part 21 Rept Re Existence of Goldfish in Spray Pond, Initially Reported 820303.Goldfish Elimination Will Be Completed Prior to Summer 1982.Util Will Periodically Examine Pond to Preclude Reintroduction of Fish Population + (23:48:37, 19 December 2024)
- 05000346/LER-1982-009, Forwards LER 82-009/03L-0 + (23:48:39, 19 December 2024)
- ML20042A549 + (23:48:42, 19 December 2024)
- ML20042A548 + (23:48:43, 19 December 2024)
- ML20042A547 + (23:48:44, 19 December 2024)
- ML20042A546 + (23:48:45, 19 December 2024)
- ML20042A545 + (23:48:46, 19 December 2024)
- 05000324/LER-1982-031-03, /03L-0:on 820209,water Leak Dripping on Primary Containment Atmospheric Monitor 2-CAC-ATH-1263,came in Contact W/Monitor Power Supply Transformer Resulting in Loss of Power.Transformer Replaced + (23:48:48, 19 December 2024)
- ML20042A543 + (23:48:50, 19 December 2024)
- 05000324/LER-1982-025-03, /03L-0:on 820215,routine Surveillance Revealed Oily Film on Inside Window to Main Steam Line Tunnel Temp High Channel B Actuation Relay A71B-K2B.Caused by Melted Insulation from Relay Coil.Relay 12HFA51A49F + (23:48:51, 19 December 2024)
- ML20042A539 + (23:48:53, 19 December 2024)
- ML20042A540 + (23:48:53, 19 December 2024)
- 05000324/LER-1982-031, Forwards LER 82-031/03L-0 + (23:48:55, 19 December 2024)
- ML20042A535 + (23:48:56, 19 December 2024)
- ML20042A533 + (23:48:58, 19 December 2024)
- ML20042A534 + (23:48:58, 19 December 2024)
- ML20042A532 + (23:48:59, 19 December 2024)
- IR 05000244/1982002 + (23:49:00, 19 December 2024)
- 05000265/LER-1982-003-03, /03L-0:on 820224,differential Pressure Switch DPIS 2-1360-1B+ Failed to Operate.Caused by Instrument Drift.Switch Recalibr & Tested Satisfactorily + (23:49:02, 19 December 2024)
- ML20042A529 + (23:49:03, 19 December 2024)
- ML20042A527 + (23:49:04, 19 December 2024)
- ML20042A526 + (23:49:05, 19 December 2024)
- 05000324/LER-1982-025, Forwards LER 82-025/03L-0 + (23:49:06, 19 December 2024)
- ML20042A523 + (23:49:08, 19 December 2024)
- 05000265/LER-1982-003, Forwards LER 82-003/03L-0 + (23:49:10, 19 December 2024)
- IR 05000333/1981025 + (23:49:11, 19 December 2024)
- ML20042A519 + (23:49:12, 19 December 2024)
- ML20042A517 + (23:49:13, 19 December 2024)
- 05000269/LER-1982-003-01, /01T-0:on 820209,steam Generator Tube Leak of Approx 0.11 Gpm Was Indicated by Condensate Steam Air Ejector Offgas Radiation Monitor.Caused by Crack on Tube 74-2.Tube Stabilized & Plugged + (23:49:15, 19 December 2024)
- ML20042A515 + (23:49:16, 19 December 2024)
- ML20042A513 + (23:49:17, 19 December 2024)
- PNO-V-82-012A, on 820315,licensee Determined Boron Concentration Water Which Resulted in Positive Reactivity Addition Was from Refueling Water Tanks.Caused by Inability to Provide Adequate Recirculation Flow & Mixing + (23:49:19, 19 December 2024)
- ML20042A511 + (23:49:20, 19 December 2024)
- 05000282/LER-1982-003-03, /03L-0:on 820209,during Annual Visual Insp,One Steam Exclusion Control Damper Found Inoperable.Caused by Failure of Drive Gear in Pacific Air Products Damper Model R-35-FS.Gear Replaced + (23:49:21, 19 December 2024)
- 05000269/LER-1982-003, Forwards LER 82-003/01T-0.Detailed Event Analysis Encl + (23:49:23, 19 December 2024)
- IR 05000458/1982001 + (23:49:24, 19 December 2024)
- ML20042A505 + (23:49:25, 19 December 2024)
- 05000282/LER-1982-003, Forwards LER 82-003/03L-0 + (23:49:27, 19 December 2024)