- 05000373/LER-1982-001-03, /03L-0:on 820417,while Performing Electrical Maint Test,Diesel Fire Pump Ob Tripped After 3 Minutes Running in Auto Position.Caused by Broken Speed Cable.Broken Cable Replaced + (09:41:50, 18 December 2024)
- ML20053A252 + (09:41:52, 18 December 2024)
- ML20053A251 + (09:41:53, 18 December 2024)
- ML20053A250 + (09:41:59, 18 December 2024)
- ML20053A249 + (09:42:00, 18 December 2024)
- ML20053A248 + (09:42:01, 18 December 2024)
- 05000373/LER-1982-001, Forwards LER 82-001/03L-0.Detailed Event Analysis Encl + (09:42:03, 18 December 2024)
- ML20053A244 + (09:42:04, 18 December 2024)
- ML20053A243 + (09:42:05, 18 December 2024)
- ML20053A242 + (09:42:07, 18 December 2024)
- ML20053A241 + (09:42:08, 18 December 2024)
- RBG-12-644, Deficiency Rept Re Insufficient End Gap of Beam Between Drywell Wall & Primary Shield Wall,Initially Reported 820302.Util Continuing Evaluation.Next Rept by 820709 + (09:42:09, 18 December 2024)
- ML20053A239 + (09:42:10, 18 December 2024)
- ML20053A238 + (09:42:12, 18 December 2024)
- ML20053A237 + (09:42:13, 18 December 2024)
- PNO-IV-82-017, on 820518,dosimetry Vendor Informed That Finger Badge from Reactor Operator Read 180 Rem (Gamma).Work Performed by Operator in Late Apr 1982 Involved Handling of Activation Products in Reactor Bldg + (09:42:18, 18 December 2024)
- ML20053A235 + (09:42:23, 18 December 2024)
- ML20053A234 + (09:42:25, 18 December 2024)
- ML20053A232 + (09:42:26, 18 December 2024)
- RBG-12-642, Final Deficiency Rept Re Pump Seal Cooling Water Piping Supplied by Byron Jackson Pump Div,Initially Reported 771202.Pump Returned for Hydrotesting of Subassembly. Deficiency Determined Not Reportable Per 10CFR50.55(e) + (09:42:28, 18 December 2024)
- ML20053A230 + (09:42:30, 18 December 2024)
- ML20053A229 + (09:42:32, 18 December 2024)
- ML20053A228 + (09:42:40, 18 December 2024)
- ML20053A226 + (09:42:41, 18 December 2024)
- ML20053A227 + (09:42:41, 18 December 2024)
- ML20053A225 + (09:42:44, 18 December 2024)
- ML20053A224 + (09:42:45, 18 December 2024)
- 05000373/LER-1982-006-03, /03L-0:on 820419,one Shift Channel Was Missed During Reactor Bldg in Fuel Pool Vent Exhaust Radiation Channel Check.Caused by Misinterpretation of Tech Specs. Personnel Reinstructed + (09:42:47, 18 December 2024)
- ML20053A221 + (09:42:49, 18 December 2024)
- ML20053A220 + (09:42:57, 18 December 2024)
- IR 05000277/1981028 + (09:43:03, 18 December 2024)
- IR 05000305/1982004 + (09:43:05, 18 December 2024)
- 05000336/LER-1982-013-03, /03L-0:on 820417,while at 100% Steady State Operation,Grounded Bus Traced to 2-CH-514 (Boric Acid Emergency Supply Charging Pump Suction).Plant Trip Occurred. Caused by Ground on Motor Valve Operator Overheating + (09:43:08, 18 December 2024)
- ML20053A215 + (09:43:09, 18 December 2024)
- ML20053A214 + (09:43:11, 18 December 2024)
- ML20053A213 + (09:43:12, 18 December 2024)
- ML20053A212 + (09:43:13, 18 December 2024)
- ML20053A211 + (09:43:19, 18 December 2024)
- ML20053A210 + (09:43:19, 18 December 2024)
- ML20053A209 + (09:43:20, 18 December 2024)
- ML20053A208 + (09:43:21, 18 December 2024)
- ML20053A207 + (09:43:23, 18 December 2024)
- ML20053A206 + (09:43:24, 18 December 2024)
- 05000373/LER-1982-009-03, /03L-0:on 820505,during Surveillance,Level Scram Switch 1B21-NO24D Had Excessive Hysterisis.Caused by Switch Cam Rubbing Against Switch Plate Spacer.Work Request Initiated 820506 & Level Switch Declared Operable + (09:43:26, 18 December 2024)