Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20077J028 + (06:27:13, 15 December 2024)
- 05000277/LER-1983-020-03, /03L-0:on 830629,during Visual Investigation of Penetration Fire Barriers,Inadequacies Found in Penetration Seals in Control Room.Caused by Const or Design Error. Temporary Sealing Followed by Seal Upgrade in Progress + (06:27:15, 15 December 2024)
- ML20077J025 + (06:27:16, 15 December 2024)
- 05000334/LER-1983-020-03, /03L-0:on 830629,wire on Terminal Block for Emergency Bus Supply Breaker 1D10 Lifted Prematurely Prior to Establishing Electrical Clearance,Causing Breaker to Trip.Const Procedures Modified + (06:27:18, 15 December 2024)
- PLA-1765, Final Deficiency Rept Re Feedwater Bypass Leakage & Potential Excessive Offsite Dose.Util Will Evaluate Sys Mods to Restore Original Design.Fsar Will Be Revised to Reflect Any Required Changes.Also Reported Per Part 21 + (06:27:19, 15 December 2024)
- ML20077J018 + (06:27:19, 15 December 2024)
- ML20077J017 + (06:27:20, 15 December 2024)
- 05000277/LER-1983-016-03, Isolation Valve SV2671C in One Sample Line to Drywell Oxygen Analyzers Failed to Fully Close.Caused by Bent Stem in Isolation Valve.Valve Disassembled & Damaged Parts Replaced + (06:27:22, 15 December 2024)
- ML20077J013 + (06:27:23, 15 December 2024)
- ML20077J010 + (06:27:23, 15 December 2024)
- 05000311/LER-1983-037-03, /03L-0:from 830705-07,four Steam Generator Safety Valves Found to Have Lift Settings Less than Required by Tech Specs.Caused by Inadequacies in Surveillance Procedures & Maint on Valves.Valves Reset + (06:27:25, 15 December 2024)
- 05000311/LER-1983-033-03, /03L-0:on 830707,during Start of Auxiliary Feedwater Pump 23 for Monthly Surveillance,Large Amount of Steam Emitted from Pump Vicinity.Caused by Hole in Pump Steam Supply Drain Line.Leaky Section Replaced + (06:27:27, 15 December 2024)
- ML20077H997 + (06:27:28, 15 December 2024)
- ML20077H996 + (06:27:29, 15 December 2024)
- ML20077H993 + (06:27:29, 15 December 2024)
- ML20077H992 + (06:27:30, 15 December 2024)
- ML20077H991 + (06:27:31, 15 December 2024)
- ML20077H990 + (06:27:31, 15 December 2024)
- ML20077H989 + (06:27:32, 15 December 2024)
- ML20077H985 + (06:27:33, 15 December 2024)
- ML20077H983 + (06:27:33, 15 December 2024)
- ML20077H981 + (06:27:34, 15 December 2024)
- ML20077H977 + (06:27:35, 15 December 2024)
- ML20077H976 + (06:27:36, 15 December 2024)
- ML20077H975 + (06:27:36, 15 December 2024)
- ML20077H973 + (06:27:37, 15 December 2024)
- ML20077H972 + (06:27:38, 15 December 2024)
- ML20077H971 + (06:27:38, 15 December 2024)
- ML20077H970 + (06:27:39, 15 December 2024)
- ML20077H969 + (06:27:40, 15 December 2024)
- ML20077H967 + (06:27:40, 15 December 2024)
- 05000311/LER-1983-034-03, /03L-0:on 830708,surveillance Testing Revealed Excessive Seal Leakage on Inner Door of 130-ft Elevation Containment Air Lock.Caused by Rapid Operation of Door So Door Seals Unevenly Seated in Seal Groove + (06:27:45, 15 December 2024)
- ML20077H963 + (06:27:49, 15 December 2024)
- ML20077H964 + (06:27:49, 15 December 2024)
- ML20077H961 + (06:27:50, 15 December 2024)
- 05000280/LER-1983-029-03, /03L-0:on 830714,control Rods Powered from Cabinet 2BD Would Not Respond During PT-6.Caused by Blown Fuse in three-phase Power Supply for Cabinet 2BD.Fuse Replaced & Rod Movement Verified + (06:27:52, 15 December 2024)
- 05000280/LER-1983-028-03, /03L-0:on 830702,carbon Dioxide Tank Level Discovered to Be Less than 75%.Caused by Operator Not Monitoring Purge.Fire Watches Established & Tank Refilled to Required Level + (06:27:54, 15 December 2024)
- ML20077H956 + (06:27:55, 15 December 2024)
- 05000387/LER-1983-099-03, /03L-0:on 830629,RCIC Turbine Exhaust Valve Failed Local Leak Rate Testing.Caused by Tolerances Between Hard & Resilient Seats W/O Good Seating Surface.Resilient Seat Replaced + (06:27:56, 15 December 2024)
- ML20077H954 + (06:27:57, 15 December 2024)
- ML20077H952 + (06:27:58, 15 December 2024)
- 05000289/LER-1983-016-03, /03L-0:on 830703,liquid Effluent Radiation Monitor RM-L7 Had No Sample Flow Through Monitor.Caused by Mechanical Seizure.Pump & Motor Replaced + (06:27:59, 15 December 2024)
- ML20077H942 + (06:28:00, 15 December 2024)
- JAFP-83-0817, Monthly Operating Rept for Jul 1983 + (06:28:01, 15 December 2024)
- ML20077H937 + (06:28:01, 15 December 2024)
- ML20077H935 + (06:28:02, 15 December 2024)
- W3P83-2269, Comments on Fire Water Sys Connection (Tertiary Backup) to Lubrication & Cooling Water for Circulating Water Pump. Three-inch Connection Is Tertiary Backup Means of Supply to Circulating Water Sys Which Is Normally Closed + (06:28:02, 15 December 2024)
- ML20077H934 + (06:28:03, 15 December 2024)
- PLA-1762, Interim Deficiency Rept Re Scram Discharge Vol Vent,Drain Valve & Water Hammer Loads.Initially Reported on 830628. Performance of Analysis to Determine Load & Impact Underway. Also Reported Per Part 21 + (06:28:04, 15 December 2024)
- ML20077H933 + (06:28:04, 15 December 2024)
- ML20077H928 + (06:28:05, 15 December 2024)