- 05000325/LER-1995-003, :on 950404,identified That non-staggered Testing of EDGs Had Occurred During Various Times of Plant Operating History.Caused by Defective Procedures & Deficiency.Testing Schedule Revised + (11:11:31, 14 December 2024)
- AECM-83-0792, Forwards Application to Amend License NPF-13,revising Tech Specs to Increase Surveillance Requirements for Rosemount Trip Units & Riley Temp Switches Listed in Table 4.3.2.1-1 + (11:11:32, 14 December 2024)
- ML20083B431 + (11:11:33, 14 December 2024)
- ML20083B422 + (11:11:33, 14 December 2024)
- ML20083B416 + (11:11:34, 14 December 2024)
- LIC-95-0093, Radiological Environ Operating Rept TS 5.9.4.b, for Period of 940101-1231 + (11:11:35, 14 December 2024)
- ML20083B415 + (11:11:35, 14 December 2024)
- 05000328/LER-1983-165-03, /03L-0:on 831115,pressurizer Safety Valve 2-VLV-68-563 Failed Seat Leakage Criteria & Lift Setpoint Could Not Be Verified.Caused by Loop Seal Loss.Valve Replaced & Mod Planned to Remove Loop Seal + (11:11:37, 14 December 2024)
- AECM-83-0782, Forwards Justification for Proposed Changes to Tech Specs Re Main Steam Line Isolation,Condenser Vacuum Low.Bypassing MSIV Closure Trip Function in Operational Conditions 2 & 3 Will Have Minimal Effect on Transient + (11:11:38, 14 December 2024)
- ML20083B393 + (11:11:39, 14 December 2024)
- ML20083B397 + (11:11:39, 14 December 2024)
- 05000338/LER-1983-083-03, /03L-0:on 831122,open Penetration Hole Discovered Between Safeguards Bldg & Quench Spray Pump House.Caused by Personnel Error.Continuous Firewatch Posted Immediately. Opening Filled + (11:11:40, 14 December 2024)
- ML20083B380 + (11:11:41, 14 December 2024)
- ML20083B370 + (11:11:42, 14 December 2024)
- ML20083B377 + (11:11:42, 14 December 2024)
- LIC-91-0099, Ro:On 910819,fire Door 1007-9 Found to Not Have Ul Label Certifying Its Fire Rating.Door Declared Inoperable. Evaluation of Door Added to Scope of Ongoing Fire Barrier Upgrade Program.Program Completion Scheduled for June 1992 + (11:11:43, 14 December 2024)
- 05000482/LER-1991-013, :on 910821,inoperability of Certain Safety Related Equipment Occurred Due to Potential of Fault in non-safety Related Circuit Propragating.Cause Unknown.Addl Insp of Conduit & Cable Performed + (11:11:44, 14 December 2024)
- ML20083B359 + (11:11:45, 14 December 2024)
- ML20083B358 + (11:11:46, 14 December 2024)
- BECO-83-294, Advises That Fees Coincident W/Tech Spec Changes Re Second 10-yr Insp Program Will Be Submitted on 840315 + (11:11:47, 14 December 2024)
- ML20083B353 + (11:11:47, 14 December 2024)
- B10961, Forwards Response to Acceptance Review Question 440.7 on Accidents Analyzed in Chapter 15 Re Limiting Single Active Component Failure.Amend Scheduled for Submittal by mid-Jan 1984 + (11:11:48, 14 December 2024)
- ML20083B338 + (11:11:48, 14 December 2024)
- W3P83-3973, Forwards Rev 2 to Training & Qualification Plan.Rev Withheld + (11:11:49, 14 December 2024)
- ML20083B300 + (11:11:50, 14 December 2024)
- 05000285/LER-1983-011-03, /03L-0:on 831111,diesel Generator DG-1 Failed to Field Flash During Surveillance Test.Caused by Damaged Relay Socket & Circuit Rectifying Diodes.Zener Diode Replaced & Regulator Adjusted + (11:11:51, 14 December 2024)
- ML20083B298 + (11:11:52, 14 December 2024)
- ML20083B266 + (11:11:53, 14 December 2024)
- ML20083B238 + (11:11:55, 14 December 2024)
- ML20083B236 + (11:11:55, 14 December 2024)
- ML20083B227 + (11:11:56, 14 December 2024)
- ML20083B228 + (11:11:56, 14 December 2024)
- ML20083B205 + (11:11:57, 14 December 2024)
- ML20083B208 + (11:11:57, 14 December 2024)
- 05000220/LER-1983-037-03, /03L-0:on 831110,during Routine Surveillance Testing on Core Spray Sys,Leakage from Vent Line Observed on Core Spray Topping Pump 121.Caused by Cracked 3/4-inch Diameter Nipple on Pump Vent Line 121 + (11:11:59, 14 December 2024)
- 05000321/LER-1983-108-03, /03L-0:on 831121,during Safety/Relief Valve Position Primary & Secondary Indicators Ft&C Procedure HNP-1-3820,safety Relief Valve Tail Pipe Pressure Switches Actuated at 102 & 78 Psig,Respectively + (11:12:01, 14 December 2024)
- ML20083B160 + (11:12:02, 14 December 2024)
- ML20083B156 + (11:12:03, 14 December 2024)
- ML20083B148 + (11:12:03, 14 December 2024)
- 05000370/LER-1983-069-03, /03L-0:on 831025,annunciator A-5 (Ice Condenser Lower Inlet Door Open) Failed to Alarm & Declared Inoperable.Caused by Failed Logic Card in Annunciator Circuit.Failed Card Replaced & Annunciator Tested + (11:12:05, 14 December 2024)
- ML20083B111 + (11:12:06, 14 December 2024)
- ML20083B116 + (11:12:06, 14 December 2024)
- ML20083B101 + (11:12:07, 14 December 2024)
- ML20083B100 + (11:12:07, 14 December 2024)
- ML20083B090 + (11:12:08, 14 December 2024)
- 3F0991-09, Forwards Util Submittal to EPA of Request to Treat Surface Condenser Cooling Water of Unit 3 w/Copper-Trol CU-1 + (11:12:09, 14 December 2024)
- ML20083B080 + (11:12:09, 14 December 2024)
- ML20083B077 + (11:12:10, 14 December 2024)
- ML20083B076 + (11:12:10, 14 December 2024)
- 05000369/LER-1983-106-03, /03L-0:on 831025,invalid Fire Alarm for Fire Detection Zone 152 Received in Control Room Which Would Not Reset.Caused by Corroded Circuitry Board of One Ionization Type Detector.Detector Replaced + (11:12:12, 14 December 2024)
- 05000395/LER-1983-129-03, /03L-0:on 831121,during Surveillance Testing,Four Fire Dampers for Relay Room Carbon Dioxide Sys Failed to Close.Caused by Electrical Thermal Link Wiring Terminator Problem & Debris on Damper Tracks + (11:12:14, 14 December 2024)