- ML20151G548 + (11:33:58, 11 December 2024)
- ML20151G546 + (11:33:59, 11 December 2024)
- ML20151G543 + (11:34:00, 11 December 2024)
- ML20151G537 + (11:34:01, 11 December 2024)
- ML20151G541 + (11:34:01, 11 December 2024)
- ML20151G534 + (11:34:02, 11 December 2024)
- IR 05000245/1988003 + (11:34:04, 11 December 2024)
- ML20151G531 + (11:34:05, 11 December 2024)
- ML20151G523 + (11:34:06, 11 December 2024)
- ML20151G524 + (11:34:06, 11 December 2024)
- ML20151G521 + (11:34:07, 11 December 2024)
- 05000313/LER-1988-004, :on 880210,reactor Bldg Hydrogen Concentration Instrument Observed Inoperable During Operability Verification Test.Caused by Wires Not Terminated on Correct Terminal Block Locations.Wiring Corrected + (11:34:09, 11 December 2024)
- NLS8800368, Responds to NRC Bulletin 87-002,Suppls 1 & 2, Fastener Testing to Determine Conformance W/Applicable Matl Specs + (11:34:10, 11 December 2024)
- ML20151G512 + (11:34:10, 11 December 2024)
- ML20151G511 + (11:34:11, 11 December 2024)
- ML20151G504 + (11:34:12, 11 December 2024)
- ML20151G509 + (11:34:12, 11 December 2024)
- 05000368/LER-1988-003-01, :on 880310,unplanned Automatic Actuation of ESFAS Occurred Due to Deenergizing of Electrical Distribution Sys Vital Power Panel for Maint.Caused by Drift of Time Delay Relay.Relay Recalibr + (11:34:14, 11 December 2024)
- ML20151G492 + (11:34:15, 11 December 2024)
- ML20151G485 + (11:34:16, 11 December 2024)
- ML20151G488 + (11:34:16, 11 December 2024)
- ML20151G480 + (11:34:18, 11 December 2024)
- ML20151G477 + (11:34:18, 11 December 2024)
- 05000416/LER-1988-010, :on 880315,reactor Scram on Low Water Level Occurred.Caused by Loose Connection in Reactor Protection Sys Terminal Box de-engergizing Scram Pilot a Solenoids of Control Rods.Connection Cleaned & Tightened + (11:34:20, 11 December 2024)
- ML20151G469 + (11:34:21, 11 December 2024)
- ML20151G460 + (11:34:22, 11 December 2024)
- ML20151G456 + (11:34:23, 11 December 2024)
- ML20151G458 + (11:34:23, 11 December 2024)
- ML20151G455 + (11:34:24, 11 December 2024)
- ML20151G454 + (11:34:24, 11 December 2024)
- ML20151G452 + (11:34:25, 11 December 2024)
- ML20151G453 + (11:34:25, 11 December 2024)
- ML20151G450 + (11:34:26, 11 December 2024)
- ML20151G451 + (11:34:26, 11 December 2024)
- ML20151G449 + (11:34:27, 11 December 2024)
- ML20151G447 + (11:34:27, 11 December 2024)
- ML20151G446 + (11:34:28, 11 December 2024)
- 05000457/LER-1988-013-04, :on 880621,reactor Trip Occurred as Result of lo-lo Steam Generator Level Due to Insufficient Feedwater Flow to Steam Generator 2A.Caused by Procedural Deficiency. Feedwater Line Restored + (11:34:30, 11 December 2024)
- ML20151G441 + (11:34:31, 11 December 2024)
- ML20151G442 + (11:34:31, 11 December 2024)
- ML20151G439 + (11:34:32, 11 December 2024)
- ML20151G440 + (11:34:32, 11 December 2024)
- ML20151G438 + (11:34:33, 11 December 2024)
- ML20151G435 + (11:34:33, 11 December 2024)
- ML20151G433 + (11:34:34, 11 December 2024)
- ML20151G432 + (11:34:35, 11 December 2024)
- ML20151G428 + (11:34:35, 11 December 2024)
- ML20151G424 + (11:34:36, 11 December 2024)
- ML20151G423 + (11:34:36, 11 December 2024)
- ML20151G418 + (11:34:37, 11 December 2024)
- ML20151G416 + (11:34:38, 11 December 2024)