Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- W3P89-0320, Corrects Cask Number Ref in Requesting Registration as User of Certificate of Compliance 9159.Util Will Be Using Cask Nupac 14/190H + (ML20247P552)
- IR 05000260/1989029 + (ML20247P553)
- 05000424/LER-1998-004, :on 980420,ECCS Accumulators Were Unable to Mitigate Consequences of an Accident.Caused by Incorrect Application of Scaling Data Into Calibration Procedures. Revised Calibration Procedures + (ML20247P554)
- ML20247P555 + (ML20247P555)
- ML20247P557 + (ML20247P557)
- ML20247P559 + (ML20247P559)
- ML20247P561 + (ML20247P561)
- ML20247P565 + (ML20247P565)
- ML20247P566 + (ML20247P566)
- B17252, Provides Alternative to Requirements of ASME Boiler & Pressure Vessel Code,Section III,NC-3677.3,1971 Edition Summer 1973 Addenda for Relief Valve Discharge to Common Header,Iaw 10CFR50.55a(a)(3)(i) + (ML20247P567)
- ML20247P570 + (ML20247P570)
- ML20247P571 + (ML20247P571)
- ML20247P572 + (ML20247P572)
- ML20247P574 + (ML20247P574)
- 05000336/LER-1997-022-03, Forwards LER 97-022-03,documenting Event That Occurred at Millstone Nuclear Power Station,Unit 2 on 970602.LER Suppl Provides Update on Results of Analyses & Investigation.Util Commitments Made within Ltr Included in Attachm + (ML20247P575)
- ML20247P577 + (ML20247P577)
- 05000333/LER-1989-014, :on 890817,HPCI Pump Turbine Declared Inoperable Due to Water in Lubricating Oil.Caused by Leaking Steam Supply Isolation Valve.Turbine Oil Sump Drained & Refilled W/New Oil + (ML20247P578)
- 05000364/LER-1998-004, Forwards LER 98-004-00,IAW 10CFR50.73(a)(2)(i).Commitments Made within Ltr,Listed + (ML20247P582)
- ML20247P585 + (ML20247P585)
- ML20247P586 + (ML20247P586)
- ML20247P587 + (ML20247P587)
- ML20247P592 + (ML20247P592)
- 05000364/LER-1998-004-01, :on 980420,failure to Perform Penetration Room Filtration Sys SR Was Noted.Caused by Personnel Error.Note Has Been Corrected & Initial Review of Surveillance Schedules Have Been Performed + (ML20247P595)
- ML20247P597 + (ML20247P597)
- ML20247P602 + (ML20247P602)
- ML20247P606 + (ML20247P606)
- 05000289/LER-1998-005, Forwards LER 98-005-00 Re Inoperable Fire Dampers Determined Reportable on 980416.No New Commitments Made within Ltr + (ML20247P609)
- ML20247P612 + (ML20247P612)
- ML20247P613 + (ML20247P613)
- ML20247P614 + (ML20247P614)
- ML20247P616 + (ML20247P616)
- ML20247P620 + (ML20247P620)
- 05000374/LER-1989-012-03, :on 890829,reactor Protection Sys Bus B Transfer Isolated,Causing Loss of Power to Shutdown Cooling Outboard Isolation Logic.Caused by Relay 2B21h-K35B Being Depressed Off Ctr.Isolation Logic Reset + (ML20247P622)
- ML20247P623 + (ML20247P623)
- ML20247P625 + (ML20247P625)
- ML20247P633 + (ML20247P633)
- 05000374/LER-1988-014-01, :on 881017,Type B & Type C Total Containment Leakage Exceeded Tech Spec Limit of 0.6La in Hydrogen Recombined Gas Control Valve.Caused by Dirty Seats on Valve.Seats Cleaned & Lapped + (ML20247P634)
- ML20247P635 + (ML20247P635)
- ML20247P636 + (ML20247P636)
- ML20247P639 + (ML20247P639)
- ML20247P643 + (ML20247P643)
- ML20247P644 + (ML20247P644)
- JPN-89-038, Forwards Application for Amend to License DPR-59,revising Tech Spec Table 4.7-2 Re Exceptions to Type C Leak Rate Tests to Accurately Reflect as-built Configuration of Plant + (ML20247P650)
- 05000336/LER-1989-007, :on 890613,condensate Polishing Facility Radiation Monitor 2-CND-RE-245 Operated W/O Source Check. Caused by Personnel Error.No Corrective Action Taken as Check Added to Procedure Before Violation + (ML20247P652)
- ML20247P654 + (ML20247P654)
- ML20247P655 + (ML20247P655)
- 05000336/LER-1987-007, :on 870416,reactor Tripped Automatically Due to Turbine Trip Caused by Generator Exciter Field Breaker Opening.Caused by Generator Volts/Hertz Relay Actuation. Emergency Operating Procedure 2525 & 2526 Done + (ML20247P656)
- ML20247P657 + (ML20247P657)
- ML20247P658 + (ML20247P658)
- ML20247P661 + (ML20247P661)
- ML20247P662 + (ML20247P662)