- PNO-V-87-082, on 871210,fire Occurred in Temporary Tool Storage Trailer in Vicinity of Unit 2 Main Generator Transformers.Caused by 120 Volt Junction Box,Possibly Overloaded from Portable Space Heater.Fire Put Out + (ML20237A043)
- ML20237A044 + (ML20237A044)
- ML20237A045 + (ML20237A045)
- ML20237A046 + (ML20237A046)
- PNO-V-87-080, on 871204,inspectors Identified Worker Lying Down on Scaffolding Erected at Grade Level in Reactor Bldg. Individual Waiting for Addl Staging of Equipment.Security Badge Suspended & Investigation Initiated + (ML20237A047)
- ML20237A048 + (ML20237A048)
- ML20237A050 + (ML20237A050)
- ML20237A051 + (ML20237A051)
- PNO-IV-87-061A, on 871209,both RHR Trains Lost.Train a Diesel Declared Operable on 871209.Chance of Tampering Concluded Due to Investigation of Changed Mechanical Governor Setting. Diesel Generator Room Access Restricted + (ML20237A052)
- ML20237A055 + (ML20237A055)
- ML20237A056 + (ML20237A056)
- ML20237A057 + (ML20237A057)
- PNO-V-87-081, on 871209,indication of Increased Leakage in Containment Identified.Caused by Leakage from Charging Sys Valve & Steam Generator Tubesheet Drain Valve Due to Abnormal Seal Performance.Seals Examined & Valves Repaired + (ML20237A058)
- ML20237A059 + (ML20237A059)
- ML20237A061 + (ML20237A061)
- ML20237A062 + (ML20237A062)
- ML20237A063 + (ML20237A063)
- ML20237A065 + (ML20237A065)
- ML20237A068 + (ML20237A068)
- ML20237A072 + (ML20237A072)
- ML20237A074 + (ML20237A074)
- ML20237A075 + (ML20237A075)
- ML20237A076 + (ML20237A076)
- 05000454/LER-1998-016-01, :on 980616,main CR Pressure non-compliance Was Noted.Caused by Inadequate Procedural Directions.Rewrote Procedure Bap 1100-03 & Associated Matrices & Field Use Data Sheets to Ensure Technical Correctness + (ML20237A077)
- ML20237A080 + (ML20237A080)
- ML20237A081 + (ML20237A081)
- ML20237A083 + (ML20237A083)
- ML20237A084 + (ML20237A084)
- ML20237A085 + (ML20237A085)
- ML20237A086 + (ML20237A086)
- 05000285/LER-1987-036, :on 871111,inadvertent Auxiliary Feedwater Actuation Occurred.Caused by Personnel Error Due to Similarity in Switch Labeling.Labeling Changes & Rev to Procedure ST-FW-3 Will Be Implemented + (ML20237A087)
- ML20237A088 + (ML20237A088)
- ML20237A089 + (ML20237A089)
- ML20237A090 + (ML20237A090)
- 05000269/LER-1987-010-04, :on 871105,manual Reactor Trip Occurred Due to Component Failure During Startup Physics Testing.Caused by Loose Solder Joint at Pin 1 of Control Rod Sequencer Card. Joint Repaired + (ML20237A092)