- I December 8, 1987 Project No. 675 Mr. A. E. Scherer, Director Nuclear Licensing Combustion Engineering 100 Prospect Hill Road Post Office Box 500 Windsor, Connecticut 06095-0500
Dear Mr. Scherer:
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION CONCERNING CHAPTER 1, QA, CESSAR-DC Our Quality Assurance Branch has reviewed Chapter 1, Amendment 12 of System 80+ CESSAR-DC, transmitted by your letter dated September 18, 1987, and has identified additional information which is needed in order to continue the review. The enclosed Request For Additional Information provides the identification of the needed information. Our schedule calls for the information to be received within 90 days from the date of this letter.
Sincerely, 9"
Gu iss ng, oject Manager Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects III, IV, V and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
As stated 8712140235 871208 P
cc: See next page 6
PDR DISTRIBUTION:
i Central. File SHWeiss
/
NRC'PDR~
JSpraul I
. g' l' L
PDSNP Reading JPartlow GVissing EJordan p
EHylton 0GC-BETH
()J'()
gr LRubenstein ACRS (10) g' O
PDSNP/)
PDSU PDSN GVi 69 Ely on LRubtnstein 12
/87 12/f /87 12/$/87
[p ssa
'o
- UNITED STATES
- ~
Ig NUCLEAR REGULATORY COMMISSION o
h WASHINGTON, D. C. 20555
'd t
p' December 8, 1987
- .+
Project No. 675 Mr. A. E. Scherer, Director Nuclear Licensing Combustion Engineering-100 Prospect Hill Road Post Office Box 500 Windsor, Connecticut 06095-0500
Dear Mr. Scherer:
SUBJECT:
REQUEST FOR ADDITIONAL-INFORMATION CONCERNING CHAPTER 1, QA,
=CESSAR-DC Our Quality Assurance Brcnch has reviewed Chapter 1, Amendment 12 of System 80+ CESSAR-DC, transmitted by your letter dated September 18, 1987, and has identified additional information which is needed in order to continue
-the review. The enclosed Request For Additional Information provides the identification of the needed information. Our schedule calls for the information to be received within 90 days from the date of this letter.
Sincerely, y S. Vissings )roject Manager Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects III, IV, V and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
As stated cc: See next page
,o
'.?
Combustion Engineering, Inc.
Project No. 675 Advanced CESSAR cc:.Mr. A. E. Scherer, Director l
Nuclear Licensing.
l Combustion Engineering,-Inc.-
1000 Prospect Hill Road Windsor, Connecticut 06095 Mr. C. B. Brinkman, Manager-Washington Nuclear Operations Combustion Engineering, Inc.
7910 Woodmont Avenue, Suite.1310 B9thesda, Maryland 20814 4
)
)
REQUEST FOR ADDITIONAL INFORf!ATION CONCERNING QUALITY ASSURANCE BRANCH REVIEW OF CHAPTER 1, AMENDMENT NO. 12 0F COMBUSTION ENGINEERING SYSTEM 80+ DESIGN, CESSAR-DC PROJECT NO. 675 1.
Section 1.8 in Amendment 12 addresses CE's commitment to Regulatory Guides.
In the area of Quality Assurance (QA), Table 1.8-1 should be updated to include the following Regulatory Guides in accordance with Section 17.1 of the Standard Review Plan (NUREG-0800) and EPRI"s. "ALWR Utility Requirements Document," June 1986.
Regulatory Guide Issue Date Comment 1.26 2/76 1.28 8/85 (NQA-1 in view of N45.2) 1.30 8/72 1.37 3/73 1.38 5/77 1.39 9/77 1.94 4/76 1.116 6/76 Note that commitment to Regulatory Guides 1.58, 1.64, 1.74, 1.88, 1.123, 1.144 and 1.146 is not required based on the commitment to the 8/85 revision of Regulatory Guide 1.28 and NQA-1.
,