- ML20236S764 + (ML20236S764)
- IA-98-260, Final Response to FOIA Request for Documents.Records in App a Encl & Already Available in PDR + (ML20236S765)
- ML20236S765 + (ML20236S765)
- IR 05000412/1987050 + (ML20236S766)
- ML20236S768 + (ML20236S768)
- ML20236S770 + (ML20236S770)
- ML20236S772 + (ML20236S772)
- 05000327/LER-1987-066, :on 871022,determined That Component Cooling Water Sys (Ccws) Pump Seal Leakage Could Deplete Ccws Water Inventory in 52 H Following Loca.Caused by Lack of Analysis on Leakage Rates.Procedures Will Be Revised + (ML20236S773)
- ML20236S775 + (ML20236S775)
- IR 07100027/2011003 + (ML20236S778)
- ML20236S780 + (ML20236S780)
- ML20236S782 + (ML20236S782)
- ML20236S785 + (ML20236S785)
- NL-20-1000, Responses to NRC Requests for Additional Information to License Amendment Request to Revise the Required Actions of Technical Specifications 3.8.1, AC Sources - Operating, for One-Time Extension of Completion Time + (ML20236S786)
- ML20236S787 + (ML20236S787)
- ML20236S788 + (ML20236S788)
- NSD-NRC-98-5799, Forwards non-proprietary & Proprietary Versions of Analysis of Boron Dilution Transients in AP600, Final Rept,In Response to .Proprietary Version Withheld + (ML20236S791)
- 05000461/LER-1987-064, :on 871102,Div 3 Diesel Generator Automatically Started While Technician Disconnected Undervoltage Relay. Caused by Inadequate Procedure & Personnel Error.Procedure Revised & Technicians Trained + (ML20236S792)
- IR 05000498/1987043 + (ML20236S794)
- ML20236S796 + (ML20236S796)
- 05000282/LER-1987-007-01, :on 870516,turbine-driven Auxiliary Feedwater Pump Inoperable.Caused by Presence of Mixture of Sludge & Broken Clamshells in Cooling Water Supply Line.Foreign Matl Removed from All Pumps + (ML20236S797)
- ML20236S798 + (ML20236S798)
- ML20236S799 + (ML20236S799)
- ML20236S801 + (ML20236S801)
- ML20236S803 + (ML20236S803)
- ML20236S804 + (ML20236S804)
- 05000327/LER-1987-068, :on 871027,discovered That Tech Spec Surveillance Interval Exceeded Due to Data Sheet Missing from Completed Surveillance Instruction.Caused by Personnel Error.Personnel Counseled.Procedure Revised + (ML20236S808)
- ML20236S810 + (ML20236S810)
- IR 05000344/1987037 + (ML20236S813)
- HL-5650, Forwards Rev 16 to Ei Hatch FSAR (Filed in Category K) & Rev 13 to Fire Hazards Analysis & Fire Protection Program (Filed in Category F) for Plant.Encl Reflects Plant Changes Through Jan 1998,satisfying 10CFR50.71 Requirements + (ML20236S814)
- ML20236S817 + (ML20236S817)
- ML20236S818 + (ML20236S818)
- TXX-7000, Deficiency Rept CP-87-24 Re Containment Liner Nelson Stud Bending in Excess of FSAR Requirements.Initially Reported on 870629.Evaluation Continuing.Next Rept Anticipated by 880210 + (ML20236S820)
- IR 05000254/1987025 + (ML20236S821)
- ML20236S825 + (ML20236S825)
- ML20236S826 + (ML20236S826)
- 05000327/LER-1987-067, :on 871027,monitor Tank Dilution Flow Not Verified During Liquid Effluent Release.Caused by Trainee Failure to Follow Procedure While Performing Batch Release. Personnel Involved Counseled + (ML20236S827)
- TXX-6997, Advises That Completion of Review of Attributes for Const Work Cateory Re Notice of Deviation Item B (Insp Rept 50-445/86-03) Revised to 871231 + (ML20236S828)
- ML20236S830 + (ML20236S830)
- ML20236S832 + (ML20236S832)
- ML20236S834 + (ML20236S834)
- IR 05000232/1967001 + (ML20236S835)
- ML20236S836 + (ML20236S836)
- 05000285/LER-1987-033, :on 870706,clarified Water Entered Instrument Air Sys During Surveillance Test of Diesel Generator Room Dry Pipe Sprinkler Sys.Caused by Foreign Matl Preventing Interfacing Check Valves from Closing + (ML20236S837)
- PNO-IV-87-059, on 871122,tractor Trailer Carrying Radwaste Overturned on Interstate 80 Spilling Some of Contents Onto Median.Shipper of Matl Dispatched Personnel & Equipment for Cleanup of Spillage.State of Wy Will Monitor Cleanup + (ML20236S838)
- 05000458/LER-1987-024, :on 871020,full Reactor Scram Signal Initiated on Reactor Protection Sys During Installation of Mod Request 85-0770.Caused by Communications Breakdown.Procedures for Work on Logic Channels Revised + (ML20236S840)
- ML20236S841 + (ML20236S841)
- 05000293/LER-1987-009, :on 871023,Failure & Malfunction Rept 87-600 Written to Document Original Design/Const Deficiency Identified During Review of Conduit Layout Drawing E-343. Caused by Deficiency in Original Plant Design + (ML20236S842)
- ML20236S844 + (ML20236S844)
- SNRC-1393, Forwards Exemption Request from 10CFR50.54(w),re Min Property Insurance Requirements,Until Plant Granted License to Operate + (ML20236S846)
- ML20236S847 + (ML20236S847)