- PNO-III-87-001B, on 870108,normal Plant Shutdown Commenced to Repair Series of Small Steam Leaks on Main Steam Piping Attachments.Leak Located on Main Turbine Stop Valve 3 & Can Only Be Isolated by Closing MSIVs + (ML20207P363)
- PNO-IV-87-003, on 870109,commenced Unit Shutdown & Cooldown to Repair Small Tube Leak in Steam Generator A.On 870110, Plant in Cold Shutdown.Licensee Plans to Place Unit Back on Line on 870118 + (ML20207P364)
- ML20207P365 + (ML20207P365)
- ML20207P367 + (ML20207P367)
- IR 05000482/1986019 + (ML20207P368)
- ML20207P368 + (ML20207P368)
- ML20207P369 + (ML20207P369)
- ML20207P370 + (ML20207P370)
- ML20207P371 + (ML20207P371)
- ML20207P373 + (ML20207P373)
- ML20207P374 + (ML20207P374)
- W3P86-2826, Forwards Response to Emergency Preparedness Deficiency Noted in Insp Rept 50-382/86-22.Corrective Actions:Layout of Emergency Facility Operations Room Will Be Changed & Addl Emergency Response Organization Positions Approved + (ML20207P375)
- ML20207P376 + (ML20207P376)
- 05000220/LER-1986-035, :on 861210,secondary Containment Temporarily Breached When Security Guard Opened Air Lock Door.Caused by Personnel Error.Clarification of Rules for Responding to Alarms at Air Lock Doors Issued + (ML20207P377)
- ML20207P379 + (ML20207P379)
- ML20207P384 + (ML20207P384)
- 05000410/LER-1986-021-01, :on 861210 & 11,HPCS Sys Initiation Experienced Due to lo-lo Water Level Signal.Caused by Inadvertent Movement of 4 Ft Section of Flexible Steel Piping Creating Hydraulic Surges.Steel Plate Removed from Rack + (ML20207P385)
- ML20207P390 + (ML20207P390)
- ML20207P392 + (ML20207P392)
- ML20207P393 + (ML20207P393)
- ML20207P394 + (ML20207P394)
- 05000237/LER-1986-029-04, :on 861213,standby Liquid Control Relief Valve a Found to Open at 1,510 Psi.Caused by Setpoint Drift. Relief Valve Setpoint Adjusted & Retested + (ML20207P395)
- 05000220/LER-1986-036, :on 861211,Door D-137 Did Not Restrict Access to Area W/Greater than 1,000 Mrem/H.Caused by Cognitive Error by Radiation Protection Supervisor.Xr Key Core in Door D-137 Switched W/H Key Core in Gate G-11 + (ML20207P396)
- ML20207P397 + (ML20207P397)
- ML20207P398 + (ML20207P398)
- ML20207P405 + (ML20207P405)
- ML20207P406 + (ML20207P406)
- ML20207P407 + (ML20207P407)
- ML20207P409 + (ML20207P409)
- ML20207P410 + (ML20207P410)
- B12395, Forwards Addl Info Supplementing Util 861113 Response to Generic Ltr 86-06 Re Manual Trip of Reactor Coolant Pumps + (ML20207P413)
- ML20207P417 + (ML20207P417)
- 05000249/LER-1986-025-05, :on 861211,reactor Scram Occurred During Cycle of Main Stop Valve (EIIS Code Ts).Caused by Closure of Three Main Stop Valves.Switch Replaced & Test Circuitry Operated as Required + (ML20207P419)
- ML20207P420 + (ML20207P420)
- ML20207P425 + (ML20207P425)
- ML20207P427 + (ML20207P427)
- ML20207P428 + (ML20207P428)
- ML20207P429 + (ML20207P429)
- ML20207P430 + (ML20207P430)
- ML20207P432 + (ML20207P432)
- ML20207P435 + (ML20207P435)
- ML20207P436 + (ML20207P436)
- ML20207P437 + (ML20207P437)
- ML20207P441 + (ML20207P441)
- ML20207P444 + (ML20207P444)
- 05000251/LER-1986-029-01, :on 861212,radioactive Particulate Containment Radiation Monitor Spiked High,Actuating Containment & Control Room Ventilation Isolation Logic.Caused by Two Broken Solder Joints & Failed Resistor + (ML20207P445)
- ML20207P446 + (ML20207P446)
- ML20207P447 + (ML20207P447)
- ML20207P448 + (ML20207P448)
- IR 05000461/1986073 + (ML20207P450)
- ML20207P451 + (ML20207P451)