- B16136, Application for Amend to License DPR-21,changing Plant,Unit 1 Instrument Calibration,Functional,Response Time,Resistance Temperature Detector & Thermocouple Testing Requirements & Clarifies Srs,Thereby Helping to Ensure Proper Testing + (ML20138K685)
- ML20138K690 + (ML20138K690)
- ML20138K691 + (ML20138K691)
- ML20138K696 + (ML20138K696)
- ML20138K699 + (ML20138K699)
- 05000249/LER-1985-019-07, :on 850923,observed That Reactor Not Vented at Less than 149 F.Caused by Failure of Shutdown Procedure to Completely Outline Conditions to Vent Reactor.Reactor Head Vents Opened + (ML20138K700)
- ML20138K702 + (ML20138K702)
- ML20138K706 + (ML20138K706)
- ML20138K712 + (ML20138K712)
- ML20138K714 + (ML20138K714)
- ML20138K717 + (ML20138K717)
- ML20138K722 + (ML20138K722)
- ST-HL-AE-1543, First Interim Deficiency Rept Re Const Damage to Low Voltage Electric Penetration Assembly Conductors.Initially Reported on 851107.Extent of Damage to Be Evaluated & Unacceptable Conductors Tagged.Next Rept Due by 860228 + (ML20138K726)
- ML20138K729 + (ML20138K729)
- ML20138K731 + (ML20138K731)
- ML20138K735 + (ML20138K735)
- ML20138K738 + (ML20138K738)
- ML20138K744 + (ML20138K744)
- ML20138K747 + (ML20138K747)
- ML20138K754 + (ML20138K754)
- ML20138K757 + (ML20138K757)
- U-602683, Provides Response to NRCs RAI Re Adequacy & Availabilty of Design Bases Info at Util,Per 10CFR50.54(f) + (ML20138K758)
- ML20138K763 + (ML20138K763)
- 05000213/LER-1984-017, :on 841004,degradation of 15-conductor Interconnection Cable Discovered.Caused by Aging.Insp for Similar Problems in Other Equipment Concluded Problem Isolated Incident.Degraded Equipment Replaced + (ML20138K765)
- ML20138K767 + (ML20138K767)
- ML20138K768 + (ML20138K768)
- ML20138K771 + (ML20138K771)
- ML20138K773 + (ML20138K773)
- 05000344/LER-1985-012, :on 850924,reactor Trip Occurred Due to lo-lo Water Level in Steam Generator D.Caused by Personnel Error Resulting in Sys Flow Oscillations.Training Info Bulletin Prepared + (ML20138K775)
- ML20138K776 + (ML20138K776)
- AECM-83-0727, Notifies That Util Will Remove Operators W/License Serials SOP-4216,OP-6239 & OP-6241 from Duties Until Addl Training Provided,Per 831104 Discussion Re Operator Training Program Deficiencies + (ML20138K781)
- ML20138K787 + (ML20138K787)
- 05000249/LER-1985-020-05, :on 850925,no Particulate Sample for Reactor Bldg Ventilation Sys Collected for Wk.Caused by Failure to Replace Screen in Filter Holder After Last Sample.Signs to Be Posted in Future + (ML20138K788)
- ML20138K789 + (ML20138K789)
- U-600349, Final Deficiency Rept 55-85-07 Re Omission of Lateral Supports on American Sprinkler Co Fire Protection Sys in Seismic Category I Bldgs.Initially Reported on 850813. Installation of Addl Supports Will Be Completed by 851215 + (ML20138K792)
- ML20138K795 + (ML20138K795)
- ML20138K796 + (ML20138K796)
- ML20138K799 + (ML20138K799)
- ML20138K800 + (ML20138K800)
- ML20138K801 + (ML20138K801)
- ML20138K803 + (ML20138K803)
- 05000348/LER-1985-015, :on 850925,determined That Positive & Negative Rate Trip Settings Existing Before 850619 Outside Tech Spec Tolerance.Caused by Incorrect Interpretation of Vendor Info. Procedure Revised + (ML20138K804)
- ML20138K808 + (ML20138K808)
- ML20138K810 + (ML20138K810)
- AECM-83-0750, Forwards Description of Corrective Actions to Strengthen Operator Training Program,Per Discussion at 831118 Meeting. Estimated Schedule for Completion Provided + (ML20138K812)
- ML20138K813 + (ML20138K813)
- ML20138K819 + (ML20138K819)
- 05000348/LER-1985-012, :on 850623,reactor Trip Occurred Due to High Negative Flux Rate.Caused by Shutdown Bank & Control Rods E-11 & L-11 Dropping Into Core Due to Electrical Short.Fuses Replaced & Cables Reterminated.Module Ordered + (ML20138K821)
- ML20138K824 + (ML20138K824)
- AECM-84-0045, Responds to Deviations Noted in Insp of License NPF-13. Corrective Actions:Three Operators Removed from Licensed Duties & Operator Recertification Program Initiated + (ML20138K825)
- ML20138K833 + (ML20138K833)